mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-06 07:49:52 +03:00
set curBurnPower for 3.party burners, #1483
This commit is contained in:
@@ -1149,8 +1149,8 @@ void Boiler::process_UBAFactory(std::shared_ptr<const Telegram> telegram) {
|
||||
void Boiler::process_UBAMonitorFast(std::shared_ptr<const Telegram> telegram) {
|
||||
has_update(telegram, selFlowTemp_, 0);
|
||||
has_update(telegram, curFlowTemp_, 1);
|
||||
has_update(telegram, selBurnPow_, 3); // burn power max setting
|
||||
has_update(telegram, curBurnPow_, 4);
|
||||
// has_update(telegram, selBurnPow_, 3); // burn power max setting
|
||||
// has_update(telegram, curBurnPow_, 4);
|
||||
has_update(telegram, boilerState_, 5); // bits 0-heat, 1-dhw, 2-service, 3-flame, 4-preheat, 5-lock-Err, 6-block-err, 7-maint
|
||||
has_bitupdate(telegram, burnGas_, 7, 0);
|
||||
has_bitupdate(telegram, burnGas2_, 7, 1);
|
||||
@@ -1184,10 +1184,20 @@ void Boiler::process_UBAMonitorFast(std::shared_ptr<const Telegram> telegram) {
|
||||
|
||||
has_update(telegram, serviceCodeNumber_, 20);
|
||||
|
||||
if (telegram->offset <= 4 && telegram->offset + telegram->message_length > 7) {
|
||||
if (burnGas_ || burnGas2_) {
|
||||
if (telegram->offset <= 3 && telegram->offset + telegram->message_length > 7) {
|
||||
// some boiler only switch burnGas and have no other burner values, https://github.com/emsesp/EMS-ESP32/discussions/1483
|
||||
uint8_t selBurnPow = selBurnPow_;
|
||||
uint8_t curBurnPow = curBurnPow_;
|
||||
telegram->read_value(selBurnPow, 3);
|
||||
telegram->read_value(curBurnPow, 4);
|
||||
if (burnGas_ && selBurnPow == 0 && curBurnPow == 0) {
|
||||
boilerState_ |= 0x08; // set flame signal
|
||||
curBurnPow = 100;
|
||||
selBurnPow = 100;
|
||||
}
|
||||
has_update(selBurnPow_, selBurnPow);
|
||||
has_update(curBurnPow_, curBurnPow);
|
||||
|
||||
check_active(); // do a quick check to see if the hot water or heating is active
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue