refactoring based on Michael's comments
This commit is contained in:
+31
-28
@@ -67,7 +67,6 @@ bool LED::loop(uint8_t healthcheck, bool button_busy) {
|
||||
set_led(Color::YELLOW); // Yellow
|
||||
} else {
|
||||
reset_led();
|
||||
previous_healthcheck_ = System::HEALTHCHECK_RESET;
|
||||
}
|
||||
return false;
|
||||
}
|
||||
@@ -75,39 +74,39 @@ bool LED::loop(uint8_t healthcheck, bool button_busy) {
|
||||
// check the system health.
|
||||
// Set the sequence accordingly, only if the healthcheck is not 0 and has changed
|
||||
if (healthcheck != previous_healthcheck_) {
|
||||
previous_healthcheck_ = healthcheck;
|
||||
color_steps_[0] = Color::OFF;
|
||||
color_steps_[1] = Color::OFF;
|
||||
color_steps_[2] = Color::OFF;
|
||||
color_steps_[0] = Color::OFF;
|
||||
color_steps_[1] = Color::OFF;
|
||||
color_steps_[2] = Color::OFF;
|
||||
|
||||
// if the healthcheck is 0, i.e. system is healthy, reset the LED
|
||||
if (healthcheck == 0) {
|
||||
reset_led();
|
||||
return false;
|
||||
} else {
|
||||
// 1 flash (blue) is the EMS bus is not connected
|
||||
// 2 flashes (red, red) if the network (wifi or ethernet) is not connected
|
||||
// 3 flashes (red, red, blue) is both the bus and the network are not connected
|
||||
bool no_network = (healthcheck & System::HEALTHCHECK_NO_NETWORK) == System::HEALTHCHECK_NO_NETWORK;
|
||||
bool no_bus = (healthcheck & System::HEALTHCHECK_NO_BUS) == System::HEALTHCHECK_NO_BUS;
|
||||
|
||||
// set step 1
|
||||
if (no_network) {
|
||||
color_steps_[0] = Color::RED; // red, no network
|
||||
} else if (no_bus) {
|
||||
color_steps_[0] = Color::BLUE; // blue, no bus
|
||||
}
|
||||
|
||||
// set step 2
|
||||
if (no_network) {
|
||||
color_steps_[1] = Color::RED; // red, no network
|
||||
}
|
||||
|
||||
// set step 3
|
||||
if (no_network && no_bus) {
|
||||
color_steps_[2] = Color::BLUE; // blue, no network and no bus
|
||||
}
|
||||
}
|
||||
|
||||
// 1 flash (blue) is the EMS bus is not connected
|
||||
// 2 flashes (red, red) if the network (wifi or ethernet) is not connected
|
||||
// 3 flashes (red, red, blue) is both the bus and the network are not connected
|
||||
bool no_network = (healthcheck & System::HEALTHCHECK_NO_NETWORK) == System::HEALTHCHECK_NO_NETWORK;
|
||||
bool no_bus = (healthcheck & System::HEALTHCHECK_NO_BUS) == System::HEALTHCHECK_NO_BUS;
|
||||
|
||||
// set step 1
|
||||
if (no_network) {
|
||||
color_steps_[0] = Color::RED; // red, no network
|
||||
} else if (no_bus) {
|
||||
color_steps_[0] = Color::BLUE; // blue, no bus
|
||||
}
|
||||
|
||||
// set step 2
|
||||
if (no_network) {
|
||||
color_steps_[1] = Color::RED; // red, no network
|
||||
}
|
||||
|
||||
// set step 3
|
||||
if (no_network && no_bus) {
|
||||
color_steps_[2] = Color::BLUE; // blue, no network and no bus
|
||||
}
|
||||
previous_healthcheck_ = healthcheck; // must be set after reset_led(), which invalidates it
|
||||
}
|
||||
|
||||
// there's nothing to flash, so leave the LED in the state reset_led() gave it.
|
||||
@@ -131,6 +130,10 @@ void LED::reset_led() {
|
||||
color_steps_[1] = Color::OFF;
|
||||
color_steps_[2] = Color::OFF;
|
||||
|
||||
// invalidate the last health state so the sequence is rebuilt on the next check,
|
||||
// needed because the color steps above have been cleared
|
||||
previous_healthcheck_ = System::HEALTHCHECK_RESET;
|
||||
|
||||
// rewind the sequence so it starts from the top if the health degrades again
|
||||
led_long_timer_ = 1; // 1 will kick it off immediately
|
||||
led_short_timer_ = 0;
|
||||
|
||||
Reference in New Issue