@@ -185,12 +185,16 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
register_device_value(TAG_BOILER_DATA, &nrgSuppCooling_, DeviceValueType::ULONG, nullptr, FL_(nrgSuppCooling), DeviceValueUOM::KWH);
|
||||
register_device_value(TAG_BOILER_DATA, &nrgSuppPool_, DeviceValueType::ULONG, nullptr, FL_(nrgSuppPool), DeviceValueUOM::KWH);
|
||||
register_device_value(TAG_BOILER_DATA, &hpPower_, DeviceValueType::UINT, FL_(div10), FL_(hpPower), DeviceValueUOM::KW);
|
||||
register_device_value(TAG_BOILER_DATA, &hpCompRunning_, DeviceValueType::BOOL, nullptr, FL_(hpCompRunning), DeviceValueUOM::BOOLEAN);
|
||||
register_device_value(TAG_BOILER_DATA, &hpCompOn_, DeviceValueType::BOOL, nullptr, FL_(hpCompOn), DeviceValueUOM::BOOLEAN);
|
||||
register_device_value(TAG_BOILER_DATA, &hpActivity_, DeviceValueType::ENUM, FL_(enum_hpactivity), FL_(hpActivity), DeviceValueUOM::LIST);
|
||||
register_device_value(TAG_BOILER_DATA, &hpHeatingOn_, DeviceValueType::BOOL, nullptr, FL_(hpHeatingOn), DeviceValueUOM::BOOLEAN);
|
||||
register_device_value(TAG_BOILER_DATA, &hpCoolingOn_, DeviceValueType::BOOL, nullptr, FL_(hpCoolingOn), DeviceValueUOM::BOOLEAN);
|
||||
register_device_value(TAG_BOILER_DATA, &hpWwOn_, DeviceValueType::BOOL, nullptr, FL_(hpWwOn), DeviceValueUOM::BOOLEAN);
|
||||
register_device_value(TAG_BOILER_DATA, &hpPoolOn_, DeviceValueType::BOOL, nullptr, FL_(hpPoolOn), DeviceValueUOM::BOOLEAN);
|
||||
register_device_value(TAG_BOILER_DATA, &hpBrinePumpSpd_, DeviceValueType::UINT, nullptr, FL_(hpBrinePumpSpd), DeviceValueUOM::PERCENT);
|
||||
register_device_value(TAG_BOILER_DATA, &hpSwitchValve_, DeviceValueType::BOOL, nullptr, FL_(hpSwitchValve), DeviceValueUOM::BOOLEAN);
|
||||
register_device_value(TAG_BOILER_DATA, &hpCompSpd_, DeviceValueType::UINT, nullptr, FL_(hpCompSpd), DeviceValueUOM::PERCENT);
|
||||
register_device_value(TAG_BOILER_DATA, &hpCircSpd_, DeviceValueType::UINT, nullptr, FL_(hpCircSpd), DeviceValueUOM::PERCENT);
|
||||
register_device_value(TAG_BOILER_DATA, &hpActivity_, DeviceValueType::ENUM, FL_(enum_hpactivity), FL_(hpActivity), DeviceValueUOM::LIST);
|
||||
register_device_value(TAG_BOILER_DATA, &hpBrineIn_, DeviceValueType::SHORT, FL_(div10), FL_(hpBrineIn), DeviceValueUOM::DEGREES);
|
||||
register_device_value(TAG_BOILER_DATA, &hpBrineOut_, DeviceValueType::SHORT, FL_(div10), FL_(hpBrineOut), DeviceValueUOM::DEGREES);
|
||||
register_device_value(TAG_BOILER_DATA, &hpSuctionGas_, DeviceValueType::SHORT, FL_(div10), FL_(hpSuctionGas), DeviceValueUOM::DEGREES);
|
||||
@@ -675,13 +679,37 @@ void Boiler::process_UBAEnergySupplied(std::shared_ptr<const Telegram> telegram)
|
||||
|
||||
void Boiler::process_HpPower(std::shared_ptr<const Telegram> telegram) {
|
||||
has_update(telegram->read_value(hpPower_, 11));
|
||||
has_update(telegram->read_bitvalue(hpCompRunning_, 3, 4));
|
||||
has_update(telegram->read_bitvalue(hpCompOn_, 3, 4));
|
||||
has_update(telegram->read_value(hpBrinePumpSpd_, 5));
|
||||
has_update(telegram->read_value(hpCompSpd_, 17));
|
||||
has_update(telegram->read_value(hpCircSpd_, 4));
|
||||
has_update(telegram->read_bitvalue(hpSwitchValve_, 0, 4));
|
||||
has_update(telegram->read_value(hpActivity_, 7));
|
||||
|
||||
hpHeatingOn_ = 0;
|
||||
hpCoolingOn_ = 0;
|
||||
hpWwOn_ = 0;
|
||||
hpPoolOn_ = 0;
|
||||
|
||||
switch (hpActivity_) {
|
||||
case 1: {
|
||||
hpHeatingOn_ = 0xFF;
|
||||
break;
|
||||
}
|
||||
case 2: {
|
||||
hpCoolingOn_ = 0xFF;
|
||||
break;
|
||||
}
|
||||
case 3: {
|
||||
hpWwOn_ = 0xFF;;
|
||||
break;
|
||||
}
|
||||
case 4: {
|
||||
hpPoolOn_ = 0xFF;;
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
||||
}
|
||||
|
||||
// Heatpump outdoor unit - type 0x48F
|
||||
|
||||
@@ -167,7 +167,7 @@ class Boiler : public EMSdevice {
|
||||
|
||||
// heatpump
|
||||
uint8_t hpPower_;
|
||||
uint8_t hpCompRunning_;
|
||||
uint8_t hpCompOn_;
|
||||
uint8_t hpBrinePumpSpd_;
|
||||
uint8_t hpCompSpd_;
|
||||
uint8_t hpCircSpd_;
|
||||
@@ -177,6 +177,11 @@ class Boiler : public EMSdevice {
|
||||
uint16_t hpHotGas_;
|
||||
uint8_t hpSwitchValve_;
|
||||
uint8_t hpActivity_;
|
||||
uint8_t hpHeatingOn_;
|
||||
uint8_t hpCoolingOn_;
|
||||
uint8_t hpWwOn_;
|
||||
uint8_t hpPoolOn_;
|
||||
uint8_t hpHeatingOn;
|
||||
int16_t hpTc0_;
|
||||
int16_t hpTc1_;
|
||||
int16_t hpTc3_;
|
||||
|
||||
@@ -26,15 +26,15 @@ uuid::log::Logger Mixer::logger_{F_(mixer), uuid::log::Facility::CONSOLE};
|
||||
|
||||
Mixer::Mixer(uint8_t device_type, uint8_t device_id, uint8_t product_id, const std::string & version, const std::string & name, uint8_t flags, uint8_t brand)
|
||||
: EMSdevice(device_type, device_id, product_id, version, name, flags, brand) {
|
||||
|
||||
|
||||
LOG_DEBUG(F("Adding new Mixer with device ID 0x%02X"), device_id);
|
||||
|
||||
if (flags == EMSdevice::EMS_DEVICE_FLAG_MP) {
|
||||
type_ = Type::MP;
|
||||
register_telegram_type(0x5BA, F("HpPoolStatus"), true, MAKE_PF_CB(process_HpPoolStatus));
|
||||
register_device_value(TAG_MP, &poolTemp_, DeviceValueType::SHORT, FL_(div10), FL_(poolTemp), DeviceValueUOM::DEGREES);
|
||||
register_device_value(TAG_MP, &poolShuntStatus_, DeviceValueType::ENUM, FL_(enum_shunt), FL_(poolShuntStatus), DeviceValueUOM::LIST);
|
||||
register_device_value(TAG_MP, &poolShunt_, DeviceValueType::UINT, nullptr, FL_(poolShunt), DeviceValueUOM::PERCENT);
|
||||
register_device_value(TAG_NONE, &poolTemp_, DeviceValueType::SHORT, FL_(div10), FL_(poolTemp), DeviceValueUOM::DEGREES);
|
||||
register_device_value(TAG_NONE, &poolShuntStatus_, DeviceValueType::ENUM, FL_(enum_shunt), FL_(poolShuntStatus), DeviceValueUOM::LIST);
|
||||
register_device_value(TAG_NONE, &poolShunt_, DeviceValueType::UINT, nullptr, FL_(poolShunt), DeviceValueUOM::PERCENT);
|
||||
|
||||
}
|
||||
else {
|
||||
|
||||
@@ -116,8 +116,7 @@ enum DeviceValueTAG : uint8_t {
|
||||
TAG_HS13,
|
||||
TAG_HS14,
|
||||
TAG_HS15,
|
||||
TAG_HS16,
|
||||
TAG_MP
|
||||
TAG_HS16
|
||||
|
||||
};
|
||||
|
||||
|
||||
@@ -62,7 +62,7 @@
|
||||
#define EMSESP_JSON_SIZE_MEDIUM_DYN 1024 // for large json docs, using DynamicJsonDocument
|
||||
#define EMSESP_JSON_SIZE_LARGE_DYN 2048 // for very large json docs, using DynamicJsonDocument
|
||||
#define EMSESP_JSON_SIZE_XLARGE_DYN 4096 // for very very large json docs, using DynamicJsonDocument
|
||||
#define EMSESP_JSON_SIZE_XXLARGE_DYN 8192 // for extra very very large json docs, using DynamicJsonDocument
|
||||
#define EMSESP_JSON_SIZE_XXLARGE_DYN 10240 // for extra very very large json docs, using DynamicJsonDocument
|
||||
|
||||
// helpers for callback functions
|
||||
#define MAKE_PF_CB(__f) [&](std::shared_ptr<const Telegram> t) { __f(t); } // for Process Function callbacks to EMSDevice::process_function_p
|
||||
|
||||
@@ -445,7 +445,11 @@ MAKE_PSTR_LIST(auxElecHeatNrgConsWW, F("auxelecheatnrgconsww"), F("auxiliary ele
|
||||
MAKE_PSTR_LIST(auxElecHeatNrgConsPool, F("auxelecheatnrgconspool"), F("auxiliary electrical heater energy consumption pool"))
|
||||
|
||||
MAKE_PSTR_LIST(hpPower, F("hppower"), F("Compressor power output"))
|
||||
MAKE_PSTR_LIST(hpCompRunning, F("hpcomprunning"), F("Compressor active"))
|
||||
MAKE_PSTR_LIST(hpCompOn, F("hpcompon"), F("HP Compressor"))
|
||||
MAKE_PSTR_LIST(hpHeatingOn, F("hpheatingon"), F("HP Heating"))
|
||||
MAKE_PSTR_LIST(hpCoolingOn, F("hpcoolingon"), F("HP Cooling"))
|
||||
MAKE_PSTR_LIST(hpWwOn, F("hpwwon"), F("HP Warm water"))
|
||||
MAKE_PSTR_LIST(hpPoolOn, F("hppoolon"), F("HP Pool"))
|
||||
MAKE_PSTR_LIST(hpBrinePumpSpd, F("hpbrinepumpspd"), F("Brine Pump Speed"))
|
||||
MAKE_PSTR_LIST(hpCompSpd, F("hpcompspd"), F("Compressor Speed"))
|
||||
MAKE_PSTR_LIST(hpCircSpd, F("hpcircspd"), F("Circulation pump Speed"))
|
||||
|
||||