added current setpoint for RC3000

This commit is contained in:
Paul
2019-08-30 23:56:18 +02:00
parent d71dbbbd21
commit fc52861831

View File

@@ -110,11 +110,12 @@
#define EMS_OFFSET_EasyStatusMessage_curr 8 // current temp
// RC1010, RC310 and RC300 specific (EMS Plus)
#define EMS_TYPE_RCPLUSStatusMessage 0x01A5 // is an automatic thermostat broadcast giving us temps, also reading
#define EMS_TYPE_RCPLUSStatusMode 0x1AF // summer/winter mode
#define EMS_OFFSET_RCPLUSStatusMessage_mode 10 // thermostat mode (auto, manual)
#define EMS_OFFSET_RCPLUSStatusMessage_setpoint 3 // setpoint temp
#define EMS_OFFSET_RCPLUSStatusMessage_curr 0 // current temp
#define EMS_TYPE_RCPLUSStatusMessage 0x01A5 // is an automatic thermostat broadcast giving us temps, also reading
#define EMS_TYPE_RCPLUSStatusMode 0x1AF // summer/winter mode
#define EMS_OFFSET_RCPLUSStatusMessage_mode 10 // thermostat mode (auto, manual)
#define EMS_OFFSET_RCPLUSStatusMessage_setpoint 3 // setpoint temp
#define EMS_OFFSET_RCPLUSStatusMessage_curr 0 // current temp
#define EMS_OFFSET_RCPLUSStatusMessage_currsetpoint 6 // target setpoint temp
#define EMS_TYPE_RCPLUSSet 0x01B9 // setpoint temp message and mode
#define EMS_OFFSET_RCPLUSSet_mode 0 // operation mode(Auto=0xFF, Manual=0x00)