ypaindaveine
7253299469
Added retrieving settings (0xA5) (validated on RC30N), and MQTT cmd to set display, building type and language.
2020-03-22 20:02:22 +01:00
Paul
9321b53e40
start topic show datetime #347 #348
2020-03-12 14:35:08 +01:00
Paul
6397754a05
more thermostat mode generalization
2020-03-09 18:03:58 +01:00
Paul
37fe454278
use DHW temp instead of boiler temp, removed return temp - #345
2020-03-08 21:49:09 +01:00
Paul
c55ed82c30
optimize thermostat modes - #138
2020-03-08 19:41:21 +01:00
Paul
1385af3d54
added IP and version to MQTT start payload, added support for RC100/Moduline 1010, Fixed Junkers thermostat writing
2020-03-06 17:13:29 +01:00
Paul
64def6e4cd
#335 fix again
2020-03-04 21:05:15 +01:00
Paul
8874543a75
fix for #335
2020-03-04 19:19:10 +01:00
Paul
98a41db973
support writing to FR100 - #335
2020-03-03 22:23:53 +01:00
Paul
3c66031870
minor text changes
2020-03-01 17:03:52 +01:00
Paul
006fae89c4
Merge branch 'dev' of https://github.com/proddy/EMS-ESP into dev
2020-03-01 16:47:38 +01:00
Paul
4cc670f010
emsplus for Tx
2020-03-01 16:47:26 +01:00
ypaindaveine
634e7cb7cd
Added mixer log, and stub for EMS type 0xAC.
2020-03-01 12:23:13 +01:00
ypaindaveine
f06ebee15c
Corrected comment.
2020-02-29 21:33:25 +01:00
ypaindaveine
658a230ea3
Add features to WW messages (0x33, 0x34) to improve WW monitoring.
2020-02-29 21:11:49 +01:00
Paul
81188eccd9
make Moduline 200 behave like RC10
2020-02-28 14:22:41 +01:00
Paul
51535a2dcf
fix for multiple Heating Circuits on Junkers thermostats
2020-02-28 14:06:58 +01:00
Paul
9aba737f0a
added RC20 support - #334
2020-02-26 18:31:38 +01:00
Paul
52d8231229
added RC20 and SM200 to MQTT
2020-02-26 18:14:51 +01:00
Paul
e08efa7475
show SM200 in telnet console
2020-02-26 12:59:09 +01:00
Paul
42d6cb1c9d
added @PhillyGilly SM200 PR - #267
2020-02-26 12:14:16 +01:00
proddy
459610be51
text changes
2020-02-25 16:58:28 +01:00
Paul
5d7feb1722
added 2 x warm water boiler temps
2020-02-23 15:47:14 +01:00
Paul
059861a14f
use flash mem for strings when we can
2020-02-23 14:22:46 +01:00
Paul
97aaff07ef
add mqtt queue to help publish failures - #326 #298
2020-02-21 17:51:25 +01:00
Paul
9dc0de275f
fix devices scan - #326
2020-02-20 00:01:05 +01:00
Paul
93dff6493a
optimize detection of EMS devices
2020-02-19 22:22:12 +01:00
Paul
b4e1d35d86
multiple bus ids - #329
2020-02-18 16:03:54 +01:00
Paul
ce49b37a34
minor formatting - no feature changes
2020-02-16 21:32:10 +01:00
Paul
8443127401
revert last change, only send thermostat MQTT if there is a setpoint temp
2020-02-15 18:01:46 +01:00
proddy
842d47293b
fix for boiltemp - should work ith buderus and bosch
2020-02-14 20:24:58 +01:00
Paul
833694a573
always show setpoint pn RC3x0 - #256
2020-02-14 14:49:33 +01:00
Paul
fd24fe3a46
RC300 changes - #256
2020-02-13 15:40:25 +01:00
Paul
ff97b3b70b
use dallas sensor address as ID - #327
2020-02-12 22:00:45 +01:00
proddy
c801160351
minor changes to mixing
2020-02-09 22:05:11 +01:00
proddy
55225f7028
ignore setpoint temp on RC300/310 when in night mode - #256
2020-02-08 14:37:15 +01:00
Paul
7f503b166f
fix controller/thermostat clash #321
2020-02-04 22:12:29 +01:00
Paul
af3971ef02
increase buffer length to show boiler details
2020-02-03 23:51:49 +01:00
Paul
ec25636d99
some mixing minor changes
2020-02-03 23:35:35 +01:00
Paul
e8e7b22e30
fix RC30 mode - #318
2020-02-03 23:16:26 +01:00
proddy
416cd43e13
added back autodetect scan, added RC30 set temp fix, fixed detection of controllers - #318 #311
2020-02-03 17:52:39 +01:00
Paul
f969226b05
fix for HC detection - #305
2020-02-01 09:07:09 +01:00
Paul
9b3ca30959
fix non-boiler check #317
2020-01-31 22:44:35 +01:00
Paul
ce97c55822
fix for bosch boiler temp #314 and MM10 on HC2 #270
2020-01-31 11:09:58 +01:00
Paul
5140db5444
seperate boiler detection - #317
2020-01-31 00:08:04 +01:00
MichaelDvP
610b9525c7
Merge branch 'dev' of https://github.com/proddy/EMS-ESP.git into MM10
2020-01-29 08:16:25 +01:00
Paul
03489d43f4
force sel temp on RC35 temperature change - #310
2020-01-26 21:10:07 +01:00
MichaelDvP
9ad6bbfadd
Merge branch 'dev' of https://github.com/proddy/EMS-ESP.git into MM10
2020-01-20 15:16:53 +01:00
Paul
cd84881769
rename 'stats' to 'data'
2020-01-19 14:53:42 +01:00
MichaelDvP
b950cf8246
summery over last commitsto MM10
...
- add MM200 warm water circuits (#299 )
- add terminal boiler wwactive on/off command (#301 )
- show first active thermostat hc in web (instead always 1)
- add log d [id] to show messages from/to specific ID (may replace log t and log s)
- add mixer version to info
- add warm water circulation active to terminal and mqtt
- mqtt subscribe only to active hc
- change NOTSET values for short/ushort and set the compare to level (match 0x7D00, 0x8000 and 0x8300 as notset)
- add calculated flow temperature to thermostat stats
2020-01-18 19:12:53 +01:00