Commit Graph
2 Commits
Author SHA1 Message Date
gnakhandClaude Opus 5.5 0c8e496296 Merge branch 'dev' of https://github.com/emsesp/EMS-ESP32 into disinfect-duration-3278
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-10 17:48:05 +02:00
gnakhandClaude Opus 5.5 84bc0afeb7 add heat pump dhw/disinfectduration (0xEA offset 15), #3278
The DHW thermal disinfection duration (time allowed to reach the
disinfection temperature; on timeout HPC4x0 reports A01(5284)) is
sent in UBAParameterWWPlus 0xEA offset 15 in steps of 10 min, but was
not decoded. Add boiler/dhw/disinfectduration for heat pumps,
readable and writeable, range 120-240 min as on the HPC410 menu.

Tested on a Bosch Compress 3400AW with HPC410: changing the duration
on the controller writes 0xEA offset 15 (150 min -> 0F, 180 -> 12),
and writing 0B 08 EA 0F 11 from EMS-ESP made the HPC410 menu show
170 min without errors.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-10 11:09:03 +02:00