Proddy
dfe009f5c3
Add s3_16M_P_custom env to trial a trimmed framework via custom_sdkconfig
2026-10-08 23:28:40 +02:00
Proddy
af3c05247c
Merge pull request #3270 from proddy/dev
...
A few changes for 3094, 3258, 3257
2026-10-08 18:08:26 +02:00
proddy
6fa08808dd
update dev-16
2026-10-08 18:03:46 +02:00
proddy
613e3c87ae
pkg update
2026-10-08 18:03:38 +02:00
proddy
f8e7dd9244
Ack polls during gateway Tx hold ( #3094 )
2026-10-06 21:42:51 +02:00
proddy
1375f87163
add precision to voltage in HA
2026-10-04 14:29:17 +02:00
proddy
4b3f6015ee
tests for gateway speeds
2026-10-04 14:28:53 +02:00
proddy
ca79e2e09b
skip duplicate reads
2026-10-04 14:28:25 +02:00
proddy
b51d153dc5
show status in guest mode
2026-10-04 14:28:12 +02:00
proddy
79c2e5e8a1
formatting type column
2026-10-04 14:28:02 +02:00
Proddy
597939c896
Merge branch 'emsesp:dev' into dev
2026-10-04 10:18:48 +02:00
Proddy
eb4232d6c8
Merge pull request #3261 from RaHehl/fix/de-heatpump-sensor-names
...
fix: German names of heat pump sensors TC0, TC1, TC3 and TA4
2026-10-04 10:08:31 +02:00
proddy
3ea25eba43
EMSESP_TX_PRE_DELAY
2026-10-04 09:56:34 +02:00
proddy
61eaee2ffa
enable internal pull-up on the UART Rx
2026-10-04 09:22:40 +02:00
Raphael Hehl
3666f21d41
fix: German names of heat pump sensors TC0, TC1, TC3 and TA4
...
The English names of TC0, TC1 and TA4 are correct, the German
translations were not. Use the terms from the Bosch manuals.
2026-10-03 00:18:51 +02:00
proddy
e4f9d4a96d
#3257 summermode back and a test for #3094
2026-10-01 17:52:52 +02:00
proddy
635daa8ab8
chore: update generated files for v3.9.0-dev.16
2026-09-30 16:22:18 +00:00
proddy
52b24d5641
#3257
2026-09-30 18:04:34 +02:00
Proddy
619fe46a4e
Merge pull request #3255 from proddy/dev
...
update GH actions
2026-09-27 15:31:48 +02:00
Proddy
115f5281f4
Merge branch 'emsesp:dev' into dev
2026-09-27 15:17:42 +02:00
proddy
333e2d83d7
update
2026-09-27 15:10:45 +02:00
proddy
3befcb638d
update github actions
2026-09-27 14:02:09 +02:00
proddy
8a48eb75d2
formatting
2026-09-27 10:34:55 +02:00
proddy
74ff39b22e
chore: update generated files for v3.9.0-dev.15
2026-09-27 08:05:03 +00:00
Proddy
960a7a554e
Merge pull request #3254 from proddy/dev
...
minor updates
2026-09-27 09:48:36 +02:00
Proddy
4ffe8c04e9
Merge branch 'dev' into dev
2026-09-27 09:45:34 +02:00
Proddy
ebd85f96a6
Merge pull request #3252 from Bingo2023/pool-signals
...
add heatpump pool on/off, pool active, MP100 shunt setpoint and pool …
2026-09-27 09:40:44 +02:00
proddy
f768225533
revert back to Tasmota 2026.09.50
2026-09-27 09:40:12 +02:00
proddy
25d21f75ab
pkg update
2026-09-27 09:39:54 +02:00
Proddy
1e49bd54a0
Merge branch 'dev' into pool-signals
2026-09-27 09:39:20 +02:00
proddy
7fe65b7f7b
quicker restart
2026-09-27 09:28:49 +02:00
proddy
7c6101e819
prevent reboot on filesystem upload
2026-09-26 21:03:17 +02:00
proddy
684d6b132d
tasmota 2026.09.50
2026-09-26 21:03:02 +02:00
proddy
15fc5e1333
pkg update
2026-09-26 21:02:35 +02:00
Bingo2023
f550503fe9
Update locale_translations.h
...
shorten
2026-09-25 18:50:26 +02:00
Bingo2023 and Claude Opus 5.5
8cdd9f5d79
rename pool translations to MP100 block, shorter names
...
- block comment `// mixer pool` -> `// MP100 pool module`, hydrTemp moved to `// water`
- `poolpump` -> `poolrequest` (pool request, MP100 input contacts)
- shorter en/de texts: pool setpoint / Pool Soll, valve status / Ventil Status,
valve actual / Ventil Ist, valve setpoint / Ventil Soll
- existing short names (poolsettemp, pooltemp, poolshuntstatus, poolshunt) unchanged
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com >
Claude-Session: https://claude.ai/code/session_013YrkDbvxEv3ZMS7SPSKCGd
2026-09-25 18:42:45 +02:00
proddy
8c496d8f77
chore: update generated files for v3.9.0-dev.15
2026-09-25 14:42:39 +00:00
proddy
e5456293aa
#3196 - heatingpumpflow fix
2026-09-25 16:24:48 +02:00
proddy
a2f8f35285
remove void last bit
2026-09-25 16:24:25 +02:00
proddy
fb8edfb6a7
change year 2025 to 2026
2026-09-25 08:44:57 +02:00
proddy
b7a174ddea
#3196
2026-09-25 08:44:42 +02:00
proddy
446738f0d9
remove condition, now handled in erase_command
2026-09-24 22:20:26 +02:00
proddy
8b1de52f55
fix possible lost pointers, could cause a crash
2026-09-24 22:12:19 +02:00
Proddy
491bb01088
Merge pull request #3253 from proddy/dev
...
replacement for rgbLedWrite() to support new v6 of the WS2812B driver
2026-09-24 18:44:32 +02:00
Proddy
37d571b6e9
Merge branch 'emsesp:dev' into dev
2026-09-24 18:43:33 +02:00
proddy
f05105861e
update doc
2026-09-24 18:43:02 +02:00
proddy
09e8ef5403
pkg update
2026-09-24 17:29:06 +02:00
Bingo2023 and Claude Opus 5.5
1d2b916935
add heatpump pool on/off, pool active, MP100 shunt setpoint and pool pump
...
Tested with a heatpump (0x08) and MP100 pool module (0x11), custom entities
compared against RC300 operation and a power meter on the circulation pump.
- boiler `poolon` (0x48A offset 0), writable, RC300 writes 01/00
- boiler `hppoolon` (0x488 offset 0 bit 6), pool heating actually active
- pool `poolshuntset` (0x5C4 offset 0, heatpump -> MP100), shunt setpoint;
`poolshunt` follows within ~2 min
- pool `poolpump` (0x5BA offset 4), 0 = running, 2 = off. This byte is only
in MP100 -> heatpump telegrams, so the pool module now also handles
telegrams it sends to other devices
- simulator: `test pool`
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com >
Claude-Session: https://claude.ai/code/session_013YrkDbvxEv3ZMS7SPSKCGd
2026-09-24 17:24:47 +02:00
proddy
100edcefe2
optimize LED and fix some edge cases
2026-09-24 17:21:41 +02:00
proddy
eddc443d72
replacement for rgbLedWrite() to support new v6 of the WS2812B driver
2026-09-24 11:29:14 +02:00