1device namedevice typeproduct idshortnamefullnametype [options...] \| (min/max)uomwriteablediscovery entityid v3.4discovery entityidmodbus unit identifiermodbus blockmodbus scale factormodbus offsetmodbus count
2CS*800i, Logatherm WLW*boiler8resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
3CS*800i, Logatherm WLW*boiler8heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
4CS*800i, Logatherm WLW*boiler8heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
5CS*800i, Logatherm WLW*boiler8tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
6CS*800i, Logatherm WLW*boiler8selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
7CS*800i, Logatherm WLW*boiler8heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
8CS*800i, Logatherm WLW*boiler8outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
9CS*800i, Logatherm WLW*boiler8curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
10CS*800i, Logatherm WLW*boiler8rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
11CS*800i, Logatherm WLW*boiler8switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
12CS*800i, Logatherm WLW*boiler8syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
13CS*800i, Logatherm WLW*boiler8boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
14CS*800i, Logatherm WLW*boiler8headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
15CS*800i, Logatherm WLW*boiler8heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
16CS*800i, Logatherm WLW*boiler8heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
17CS*800i, Logatherm WLW*boiler8heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
18CS*800i, Logatherm WLW*boiler8pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
19CS*800i, Logatherm WLW*boiler8pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
20CS*800i, Logatherm WLW*boiler8pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
21CS*800i, Logatherm WLW*boiler8pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
22CS*800i, Logatherm WLW*boiler8pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
23CS*800i, Logatherm WLW*boiler8pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
24CS*800i, Logatherm WLW*boiler8selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
25CS*800i, Logatherm WLW*boiler8curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
26CS*800i, Logatherm WLW*boiler8burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
27CS*800i, Logatherm WLW*boiler8burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
28CS*800i, Logatherm WLW*boiler8burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
29CS*800i, Logatherm WLW*boiler8heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
30CS*800i, Logatherm WLW*boiler8heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
31CS*800i, Logatherm WLW*boiler8ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
32CS*800i, Logatherm WLW*boiler8lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
33CS*800i, Logatherm WLW*boiler8servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
34CS*800i, Logatherm WLW*boiler8servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
35CS*800i, Logatherm WLW*boiler8maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
36CS*800i, Logatherm WLW*boiler8maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
37CS*800i, Logatherm WLW*boiler8maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
38CS*800i, Logatherm WLW*boiler8maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
39CS*800i, Logatherm WLW*boiler8emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
40CS*800i, Logatherm WLW*boiler8emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
41CS*800i, Logatherm WLW*boiler8pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
42CS*800i, Logatherm WLW*boiler8pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
43CS*800i, Logatherm WLW*boiler8pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
44CS*800i, Logatherm WLW*boiler8pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
45CS*800i, Logatherm WLW*boiler8nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
46CS*800i, Logatherm WLW*boiler8dhw.nrgenergyuint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_energysensor.boiler_dhw_nrg591/10002
47CS*800i, Logatherm WLW*boiler8nrgheatenergy heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_heatingsensor.boiler_nrgheat501/100852
48CS*800i, Logatherm WLW*boiler8nrgcoolenergy coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_coolingsensor.boiler_nrgcool501/100872
49CS*800i, Logatherm WLW*boiler8metertotalmeter totaluint24 (>=0<=167772)kWhfalsesensor.boiler_meter_totalsensor.boiler_metertotal501/100892
50CS*800i, Logatherm WLW*boiler8metercompmeter compressoruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_compressorsensor.boiler_metercomp501/100912
51CS*800i, Logatherm WLW*boiler8metereheatmeter e-heateruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_e-heatersensor.boiler_metereheat501/100932
52CS*800i, Logatherm WLW*boiler8meterheatmeter heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/100952
53CS*800i, Logatherm WLW*boiler8metercoolmeter coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_coolingsensor.boiler_metercool501/100972
54CS*800i, Logatherm WLW*boiler8dhw.metermeteruint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/10022
55CS*800i, Logatherm WLW*boiler8uptimetotalheatpump total uptimetime (>=0<=279620)minutesfalsesensor.boiler_heatpump_total_uptimesensor.boiler_uptimetotal501/60992
56CS*800i, Logatherm WLW*boiler8uptimecontroltotal operating time heattime (>=0<=279620)minutesfalsesensor.boiler_total_operating_time_heatsensor.boiler_uptimecontrol501/601012
57CS*800i, Logatherm WLW*boiler8uptimecompheatingoperating time compressor heatingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_heatingsensor.boiler_uptimecompheating501/601032
58CS*800i, Logatherm WLW*boiler8uptimecompcoolingoperating time compressor coolingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_coolingsensor.boiler_uptimecompcooling501/601052
59CS*800i, Logatherm WLW*boiler8dhw.uptimecompoperating time compressortime (>=0<=279620)minutesfalsesensor.boiler_dhw_operating_time_compressorsensor.boiler_dhw_uptimecomp591/6042
60CS*800i, Logatherm WLW*boiler8uptimecomppooloperating time compressor pooltime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_poolsensor.boiler_uptimecomppool501/601072
61CS*800i, Logatherm WLW*boiler8totalcompstartstotal compressor control startsuint24 (>=0<=16777214)falsesensor.boiler_total_compressor_control_startssensor.boiler_totalcompstarts5011092
62CS*800i, Logatherm WLW*boiler8heatingstartsheating control startsuint24 (>=0<=16777214)falsesensor.boiler_heating_control_startssensor.boiler_heatingstarts5011112
63CS*800i, Logatherm WLW*boiler8coolingstartscooling control startsuint24 (>=0<=16777214)falsesensor.boiler_cooling_control_startssensor.boiler_coolingstarts5011132
64CS*800i, Logatherm WLW*boiler8dhw.startshpstarts hpuint24 (>=0<=16777214)falsesensor.boiler_dhw_starts_hpsensor.boiler_dhw_startshp59162
65CS*800i, Logatherm WLW*boiler8poolstartspool control startsuint24 (>=0<=16777214)falsesensor.boiler_pool_control_startssensor.boiler_poolstarts5011152
66CS*800i, Logatherm WLW*boiler8nrgconstotaltotal energy consumptionuint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_consumptionsensor.boiler_nrgconstotal5011172
67CS*800i, Logatherm WLW*boiler8nrgconscomptotaltotal energy consumption compressoruint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_consumption_compressorsensor.boiler_nrgconscomptotal5011192
68CS*800i, Logatherm WLW*boiler8nrgconscompheatingenergy consumption compressor heatinguint24 (>=0<=16777214)kWhfalsesensor.boiler_energy_consumption_compressor_heatingsensor.boiler_nrgconscompheating5011212
69CS*800i, Logatherm WLW*boiler8dhw.nrgconscompenergy consumption compressoruint24 (>=0<=16777214)kWhfalsesensor.boiler_dhw_energy_consumption_compressorsensor.boiler_dhw_nrgconscomp59182
70CS*800i, Logatherm WLW*boiler8nrgconscompcoolingenergy consumption compressor coolinguint24 (>=0<=16777214)kWhfalsesensor.boiler_energy_consumption_compressor_coolingsensor.boiler_nrgconscompcooling5011232
71CS*800i, Logatherm WLW*boiler8nrgconscomppoolenergy consumption compressor pooluint24 (>=0<=16777214)kWhfalsesensor.boiler_energy_consumption_compressor_poolsensor.boiler_nrgconscomppool5011252
72CS*800i, Logatherm WLW*boiler8auxelecheatnrgconstotaltotal aux elec. heater energy consumptionuint24 (>=0<=16777214)kWhfalsesensor.boiler_total_aux_elec._heater_energy_consumptionsensor.boiler_auxelecheatnrgconstotal5011272
73CS*800i, Logatherm WLW*boiler8auxelecheatnrgconsheatingaux elec. heater energy consumption heatinguint24 (>=0<=16777214)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_heatingsensor.boiler_auxelecheatnrgconsheating5011292
74CS*800i, Logatherm WLW*boiler8dhw.auxelecheatnrgconsaux elec. heater energy consumptionuint24 (>=0<=16777214)kWhfalsesensor.boiler_dhw_aux_elec._heater_energy_consumptionsensor.boiler_dhw_auxelecheatnrgcons591102
75CS*800i, Logatherm WLW*boiler8auxelecheatnrgconspoolaux elec. heater energy consumption pooluint24 (>=0<=16777214)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_poolsensor.boiler_auxelecheatnrgconspool5011312
76CS*800i, Logatherm WLW*boiler8nrgsupptotaltotal energy supplieduint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_suppliedsensor.boiler_nrgsupptotal5011332
77CS*800i, Logatherm WLW*boiler8nrgsuppheatingtotal energy supplied heatinguint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_supplied_heatingsensor.boiler_nrgsuppheating5011352
78CS*800i, Logatherm WLW*boiler8dhw.nrgsupptotal energy warm supplieduint24 (>=0<=16777214)kWhfalsesensor.boiler_dhw_total_energy_warm_suppliedsensor.boiler_dhw_nrgsupp591122
79CS*800i, Logatherm WLW*boiler8nrgsuppcoolingtotal energy supplied coolinguint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_supplied_coolingsensor.boiler_nrgsuppcooling5011372
80CS*800i, Logatherm WLW*boiler8nrgsupppooltotal energy supplied pooluint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_supplied_poolsensor.boiler_nrgsupppool5011392
81CS*800i, Logatherm WLW*boiler8hppowercompressor power outputuint16 (>=0<=3199)kWfalsesensor.boiler_compressor_power_outputsensor.boiler_hppower501/101411
82CS*800i, Logatherm WLW*boiler8hpmaxpowercompressor max poweruint8 (>=0<=100)%truenumber.boiler_compressor_max_powernumber.boiler_hpmaxpower5011421
83CS*800i, Logatherm WLW*boiler8pvmaxcomppv compressor max poweruint8 (>=0<=25)kWtruenumber.boiler_pv_compressor_max_powernumber.boiler_pvmaxcomp501/101431
84CS*800i, Logatherm WLW*boiler8powerreductionpower reductionuint8 (>=30<=60)%truenumber.boiler_power_reductionnumber.boiler_powerreduction50101441
85CS*800i, Logatherm WLW*boiler8hpsetdiffpressset differential pressureuint8 (>=150<=750)mbartruenumber.boiler_set_differential_pressurenumber.boiler_hpsetdiffpress50501451
86CS*800i, Logatherm WLW*boiler8hpcomponhp compressorbooleanfalsebinary_sensor.boiler_hp_compressorbinary_sensor.boiler_hpcompon5011461
87CS*800i, Logatherm WLW*boiler8hpactivitycompressor activityenum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm]falsesensor.boiler_compressor_activitysensor.boiler_hpactivity5011471
88CS*800i, Logatherm WLW*boiler8hpbrinepumpspdbrine pump speeduint8 (>=0<=100)%falsesensor.boiler_brine_pump_speedsensor.boiler_hpbrinepumpspd5011481
89CS*800i, Logatherm WLW*boiler8hpswitchvalveswitch valvebooleanfalsebinary_sensor.boiler_switch_valvebinary_sensor.boiler_hpswitchvalve5011491
90CS*800i, Logatherm WLW*boiler8hpcompspdcompressor speeduint8 (>=0<=100)%falsesensor.boiler_compressor_speedsensor.boiler_hpcompspd5011501
91CS*800i, Logatherm WLW*boiler8hpcircspdcirculation pump speeduint8 (>=0<=100)%falsesensor.boiler_circulation_pump_speedsensor.boiler_hpcircspd5011511
92CS*800i, Logatherm WLW*boiler8hpbrineinbrine in/evaporatorint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_in/evaporatorsensor.boiler_hpbrinein501/101521
93CS*800i, Logatherm WLW*boiler8hpbrineoutbrine out/condenserint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_out/condensersensor.boiler_hpbrineout501/101531
94CS*800i, Logatherm WLW*boiler8hptc0heat carrier return (TC0)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_return_(TC0)sensor.boiler_hptc0501/101541
95CS*800i, Logatherm WLW*boiler8hptc1heat carrier forward (TC1)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_forward_(TC1)sensor.boiler_hptc1501/101551
96CS*800i, Logatherm WLW*boiler8hptc3condenser temperature (TC3)int16 (>=-3199<=3199)Cfalsesensor.boiler_condenser_temperature_(TC3)sensor.boiler_hptc3501/101561
97CS*800i, Logatherm WLW*boiler8hptr1compressor temperature (TR1)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_temperature_(TR1)sensor.boiler_hptr1501/101571
98CS*800i, Logatherm WLW*boiler8hptr3refrigerant temperature liquid side (condenser output) (TR3)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3)sensor.boiler_hptr3501/101581
99CS*800i, Logatherm WLW*boiler8hptr4evaporator inlet temperature (TR4)int16 (>=-3199<=3199)Cfalsesensor.boiler_evaporator_inlet_temperature_(TR4)sensor.boiler_hptr4501/101591
100CS*800i, Logatherm WLW*boiler8hptr5compressor inlet temperature (TR5)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_inlet_temperature_(TR5)sensor.boiler_hptr5501/101601
101CS*800i, Logatherm WLW*boiler8hptr6compressor outlet temperature (TR6)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_outlet_temperature_(TR6)sensor.boiler_hptr6501/101611
102CS*800i, Logatherm WLW*boiler8hptr7refrigerant temperature gas side (condenser input) (TR7)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7)sensor.boiler_hptr7501/101621
103CS*800i, Logatherm WLW*boiler8hptl2air inlet temperature (TL2)int16 (>=-3199<=3199)Cfalsesensor.boiler_air_inlet_temperature_(TL2)sensor.boiler_hptl2501/101631
104CS*800i, Logatherm WLW*boiler8hppl1low pressure side temperature (PL1)int16 (>=-3199<=3199)Cfalsesensor.boiler_low_pressure_side_temperature_(PL1)sensor.boiler_hppl1501/101641
105CS*800i, Logatherm WLW*boiler8hpph1high pressure side temperature (PH1)int16 (>=-3199<=3199)Cfalsesensor.boiler_high_pressure_side_temperature_(PH1)sensor.boiler_hpph1501/101651
106CS*800i, Logatherm WLW*boiler8hpta4drain pan temp (TA4)int16 (>=-3199<=3199)Cfalsesensor.boiler_drain_pan_temp_(TA4)sensor.boiler_hpta4501/101661
107CS*800i, Logatherm WLW*boiler8hptw1reservoir temp (TW1)int16 (>=-3199<=3199)Cfalsesensor.boiler_reservoir_temp_(TW1)sensor.boiler_hptw1501/101671
108CS*800i, Logatherm WLW*boiler8poolsettemppool set temperatureuint8 (>=0<=127)Ctruenumber.boiler_pool_set_temperaturenumber.boiler_poolsettemp501/21681
109CS*800i, Logatherm WLW*boiler8hp4way4-way valve (VR4)enum [cooling & defrost\|heating & dhw]falsesensor.boiler_4-way_valve_(VR4)sensor.boiler_hp4way5011691
110CS*800i, Logatherm WLW*boiler8hpin1input 1 statebooleanfalsebinary_sensor.boiler_input_1_statebinary_sensor.boiler_hpin15011701
111CS*800i, Logatherm WLW*boiler8hpin1optinput 1 optionsstringtruesensor.boiler_input_1_optionssensor.boiler_hpin1opt5011718
112CS*800i, Logatherm WLW*boiler8hpin2input 2 statebooleanfalsebinary_sensor.boiler_input_2_statebinary_sensor.boiler_hpin25011791
113CS*800i, Logatherm WLW*boiler8hpin2optinput 2 optionsstringtruesensor.boiler_input_2_optionssensor.boiler_hpin2opt5011808
114CS*800i, Logatherm WLW*boiler8hpin3input 3 statebooleanfalsebinary_sensor.boiler_input_3_statebinary_sensor.boiler_hpin35011881
115CS*800i, Logatherm WLW*boiler8hpin3optinput 3 optionsstringtruesensor.boiler_input_3_optionssensor.boiler_hpin3opt5011898
116CS*800i, Logatherm WLW*boiler8hpin4input 4 statebooleanfalsebinary_sensor.boiler_input_4_statebinary_sensor.boiler_hpin45011971
117CS*800i, Logatherm WLW*boiler8hpin4optinput 4 optionsstringtruesensor.boiler_input_4_optionssensor.boiler_hpin4opt5011988
118CS*800i, Logatherm WLW*boiler8maxheatcompheat limit compressorenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_compressorselect.boiler_maxheatcomp5012061
119CS*800i, Logatherm WLW*boiler8maxheatheatheat limit heatingenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_heatingselect.boiler_maxheatheat5012071
120CS*800i, Logatherm WLW*boiler8dhw.maxheatheat limitenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_dhw_heat_limitselect.boiler_dhw_maxheat591141
121CS*800i, Logatherm WLW*boiler8mandefrostmanual defrostbooleantrueswitch.boiler_manual_defrostswitch.boiler_mandefrost5012081
122CS*800i, Logatherm WLW*boiler8pvcoolingcooling only with PVbooleantrueswitch.boiler_cooling_only_with_PVswitch.boiler_pvcooling5012091
123CS*800i, Logatherm WLW*boiler8auxheateronlyaux heater onlybooleantrueswitch.boiler_aux_heater_onlyswitch.boiler_auxheateronly5012101
124CS*800i, Logatherm WLW*boiler8auxheateroffdisable aux heaterbooleantrueswitch.boiler_disable_aux_heaterswitch.boiler_auxheateroff5012111
125CS*800i, Logatherm WLW*boiler8auxheaterstatusaux heater statusenum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm]falsesensor.boiler_aux_heater_statussensor.boiler_auxheaterstatus5012121
126CS*800i, Logatherm WLW*boiler8auxheaterlevelaux heater leveluint8 (>=0<=100)%falsesensor.boiler_aux_heater_levelsensor.boiler_auxheaterlevel5012131
127CS*800i, Logatherm WLW*boiler8auxheaterdelayaux heater on delayuint16 (>=10<=1000)K*mintruenumber.boiler_aux_heater_on_delaynumber.boiler_auxheaterdelay50102141
128CS*800i, Logatherm WLW*boiler8auxmaxlimitaux heater max limituint8 (>=0<=10)Ktruenumber.boiler_aux_heater_max_limitnumber.boiler_auxmaxlimit501/102151
129CS*800i, Logatherm WLW*boiler8auxlimitstartaux heater limit startuint8 (>=0<=10)Ktruenumber.boiler_aux_heater_limit_startnumber.boiler_auxlimitstart501/102161
130CS*800i, Logatherm WLW*boiler8auxheatrmodeaux heater modeenum [eco\|comfort]trueselect.boiler_aux_heater_modeselect.boiler_auxheatrmode5012171
131CS*800i, Logatherm WLW*boiler8hphystheaton/off hyst heatuint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_heatnumber.boiler_hphystheat5052181
132CS*800i, Logatherm WLW*boiler8hphystcoolon/off hyst cooluint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_coolnumber.boiler_hphystcool5052191
133CS*800i, Logatherm WLW*boiler8hphystpoolon/off hyst pooluint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_poolnumber.boiler_hphystpool5052201
134CS*800i, Logatherm WLW*boiler8silentmodesilent modeenum [off\|auto\|on]trueselect.boiler_silent_modeselect.boiler_silentmode5012211
135CS*800i, Logatherm WLW*boiler8silentfromsilent mode fromuint8 (>=0<=3810)minutestruenumber.boiler_silent_mode_fromnumber.boiler_silentfrom50152221
136CS*800i, Logatherm WLW*boiler8silenttosilent mode touint8 (>=0<=3810)minutestruenumber.boiler_silent_mode_tonumber.boiler_silentto50152231
137CS*800i, Logatherm WLW*boiler8mintempsilentmin outside temp for silent modeint8 (>=-126<=126)Ctruenumber.boiler_min_outside_temp_for_silent_modenumber.boiler_mintempsilent5012241
138CS*800i, Logatherm WLW*boiler8tempparmodeoutside temp parallel modeint8 (>=-126<=126)Ctruenumber.boiler_outside_temp_parallel_modenumber.boiler_tempparmode5012251
139CS*800i, Logatherm WLW*boiler8auxheatmixaux heater mixing valveint8 (>=-100<=100)%falsesensor.boiler_aux_heater_mixing_valvesensor.boiler_auxheatmix5012261
140CS*800i, Logatherm WLW*boiler8tempdiffheattemp diff TC3/TC0 heatuint8 (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_heatnumber.boiler_tempdiffheat501/102271
141CS*800i, Logatherm WLW*boiler8tempdiffcooltemp diff TC3/TC0 cooluint8 (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_coolnumber.boiler_tempdiffcool501/102281
142CS*800i, Logatherm WLW*boiler8vpcoolingvalve/pump coolingbooleantrueswitch.boiler_valve/pump_coolingswitch.boiler_vpcooling5012291
143CS*800i, Logatherm WLW*boiler8heatcableheating cablebooleantrueswitch.boiler_heating_cableswitch.boiler_heatcable5012301
144CS*800i, Logatherm WLW*boiler8vc0valveVC0 valvebooleantrueswitch.boiler_VC0_valveswitch.boiler_vc0valve5012311
145CS*800i, Logatherm WLW*boiler8primepumpprimary heatpumpbooleantrueswitch.boiler_primary_heatpumpswitch.boiler_primepump5012321
146CS*800i, Logatherm WLW*boiler8primepumpmodprimary heatpump modulationuint8 (>=0<=100)%truenumber.boiler_primary_heatpump_modulationnumber.boiler_primepumpmod5012331
147CS*800i, Logatherm WLW*boiler8hp3way3-way valvebooleantrueswitch.boiler_3-way_valveswitch.boiler_hp3way5012341
148CS*800i, Logatherm WLW*boiler8elheatstep1el. heater step 1booleantrueswitch.boiler_el._heater_step_1switch.boiler_elheatstep15012351
149CS*800i, Logatherm WLW*boiler8elheatstep2el. heater step 2booleantrueswitch.boiler_el._heater_step_2switch.boiler_elheatstep25012361
150CS*800i, Logatherm WLW*boiler8elheatstep3el. heater step 3booleantrueswitch.boiler_el._heater_step_3switch.boiler_elheatstep35012371
151CS*800i, Logatherm WLW*boiler8hpea0condensate reservoir heating (EA0)booleanfalsebinary_sensor.boiler_condensate_reservoir_heating_(EA0)binary_sensor.boiler_hpea05012381
152CS*800i, Logatherm WLW*boiler8hppumpmodeprimary heatpump modeenum [auto\|continuous]trueselect.boiler_primary_heatpump_modeselect.boiler_hppumpmode5012391
153CS*800i, Logatherm WLW*boiler8fanfanuint8 (>=20<=100)%truenumber.boiler_fannumber.boiler_fan5012401
154CS*800i, Logatherm WLW*boiler8shutdownshutdowncmd [off\|on]truesensor.boiler_shutdownsensor.boiler_shutdown5012411
155CS*800i, Logatherm WLW*boiler8hpcurrpowercompressor current poweruint16 (>=0<=31999)Wfalsesensor.boiler_compressor_current_powersensor.boiler_hpcurrpower5012421
156CS*800i, Logatherm WLW*boiler8hppowerlimitpower limituint16 (>=0<=31999)Wtruenumber.boiler_power_limitnumber.boiler_hppowerlimit5012431
157CS*800i, Logatherm WLW*boiler8dhw.alternatingopalternating operationbooleantrueswitch.boiler_dhw_alternating_operationswitch.boiler_dhw_alternatingop591151
158CS*800i, Logatherm WLW*boiler8dhw.altopprioheatprioritise heating during dhwuint8 (>=20<=120)minutestruenumber.boiler_dhw_prioritise_heating_during_dhwnumber.boiler_dhw_altopprioheat591161
159CS*800i, Logatherm WLW*boiler8dhw.altopprioprioritise dhw during heatinguint8 (>=30<=120)minutestruenumber.boiler_dhw_prioritise_dhw_during_heatingnumber.boiler_dhw_altopprio591171
160CS*800i, Logatherm WLW*boiler8dhw.comfoffcomfort switch offuint8 (>=15<=65)Ctruenumber.boiler_dhw_comfort_switch_offnumber.boiler_dhw_comfoff591181
161CS*800i, Logatherm WLW*boiler8dhw.ecooffeco switch offuint8 (>=15<=65)Ctruenumber.boiler_dhw_eco_switch_offnumber.boiler_dhw_ecooff591191
162CS*800i, Logatherm WLW*boiler8dhw.ecoplusoffeco+ switch offuint8 (>=48<=63)Ctruenumber.boiler_dhw_eco+_switch_offnumber.boiler_dhw_ecoplusoff591201
163CS*800i, Logatherm WLW*boiler8dhw.comfdiffcomfort diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_comfort_diffnumber.boiler_dhw_comfdiff591211
164CS*800i, Logatherm WLW*boiler8dhw.ecodiffeco diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_eco_diffnumber.boiler_dhw_ecodiff591221
165CS*800i, Logatherm WLW*boiler8dhw.ecoplusdiffeco+ diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_eco+_diffnumber.boiler_dhw_ecoplusdiff591231
166CS*800i, Logatherm WLW*boiler8dhw.comfstopcomfort stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_comfort_stop_tempnumber.boiler_dhw_comfstop591241
167CS*800i, Logatherm WLW*boiler8dhw.ecostopeco stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_eco_stop_tempnumber.boiler_dhw_ecostop591251
168CS*800i, Logatherm WLW*boiler8dhw.ecoplusstopeco+ stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_eco+_stop_tempnumber.boiler_dhw_ecoplusstop591261
169CS*800i, Logatherm WLW*boiler8dhw.hpcircpumpcirculation pump available during dhwbooleantrueswitch.boiler_dhw_circulation_pump_available_during_dhwswitch.boiler_dhw_hpcircpump591271
170CS*800i, Logatherm WLW*boiler8dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
171CS*800i, Logatherm WLW*boiler8dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
172CS*800i, Logatherm WLW*boiler8dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
173CS*800i, Logatherm WLW*boiler8dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
174CS*800i, Logatherm WLW*boiler8dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
175CS*800i, Logatherm WLW*boiler8dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
176CS*800i, Logatherm WLW*boiler8dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
177CS*800i, Logatherm WLW*boiler8dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
178CS*800i, Logatherm WLW*boiler8dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
179CS*800i, Logatherm WLW*boiler8dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
180CS*800i, Logatherm WLW*boiler8dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
181CS*800i, Logatherm WLW*boiler8dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
182CS*800i, Logatherm WLW*boiler8dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
183CS*800i, Logatherm WLW*boiler8dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
184CS*800i, Logatherm WLW*boiler8dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
185CS*800i, Logatherm WLW*boiler8dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
186CS*800i, Logatherm WLW*boiler8dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
187CS*800i, Logatherm WLW*boiler8dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
188CS*800i, Logatherm WLW*boiler8dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
189CS*800i, Logatherm WLW*boiler8dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
190CS*800i, Logatherm WLW*boiler8dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
191CS*800i, Logatherm WLW*boiler8dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
192CS*800i, Logatherm WLW*boiler8dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
193CS*800i, Logatherm WLW*boiler8dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
194CS*800i, Logatherm WLW*boiler8dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
195CS*800i, Logatherm WLW*boiler8dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
196CS*800i, Logatherm WLW*boiler8dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
197CS*800i, Logatherm WLW*boiler8dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
198CS*800i, Logatherm WLW*boiler8dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
199CS*800i, Logatherm WLW*boiler8dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
200CS*800i, Logatherm WLW*boiler8dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
201CS*800i, Logatherm WLW*boiler8dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
202CS*800i, Logatherm WLW*boiler8dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
203CS*800i, Logatherm WLW*boiler8dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
204CS*800i, Logatherm WLW*boiler8dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
205CS*800i, Logatherm WLW*boiler8dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10631
206CS*800i, Logatherm WLW*boiler8dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10641
207CS*800i, Logatherm WLW*boiler8dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591652
208CS*800i, Logatherm WLW*boiler8dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591672
209C1200Wboiler12resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
210C1200Wboiler12heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
211C1200Wboiler12heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
212C1200Wboiler12tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
213C1200Wboiler12selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
214C1200Wboiler12heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
215C1200Wboiler12outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
216C1200Wboiler12curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
217C1200Wboiler12rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
218C1200Wboiler12switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
219C1200Wboiler12syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
220C1200Wboiler12boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
221C1200Wboiler12headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
222C1200Wboiler12exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
223C1200Wboiler12burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
224C1200Wboiler12burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
225C1200Wboiler12flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
226C1200Wboiler12fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
227C1200Wboiler12ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
228C1200Wboiler12oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
229C1200Wboiler12burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
230C1200Wboiler12burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
231C1200Wboiler12burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
232C1200Wboiler12absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
233C1200Wboiler12heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
234C1200Wboiler12boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
235C1200Wboiler12boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
236C1200Wboiler12boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
237C1200Wboiler12boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
238C1200Wboiler12curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
239C1200Wboiler12curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
240C1200Wboiler12curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
241C1200Wboiler12summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
242C1200Wboiler12nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
243C1200Wboiler12nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
244C1200Wboiler12heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
245C1200Wboiler12heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
246C1200Wboiler12heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
247C1200Wboiler12pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
248C1200Wboiler12pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
249C1200Wboiler12pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
250C1200Wboiler12pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
251C1200Wboiler12pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
252C1200Wboiler12pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
253C1200Wboiler12selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
254C1200Wboiler12curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
255C1200Wboiler12burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
256C1200Wboiler12burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
257C1200Wboiler12burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
258C1200Wboiler12heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
259C1200Wboiler12heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
260C1200Wboiler12ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
261C1200Wboiler12lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
262C1200Wboiler12servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
263C1200Wboiler12servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
264C1200Wboiler12maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
265C1200Wboiler12maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
266C1200Wboiler12maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
267C1200Wboiler12maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
268C1200Wboiler12emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
269C1200Wboiler12emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
270C1200Wboiler12pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
271C1200Wboiler12pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
272C1200Wboiler12pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
273C1200Wboiler12pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
274C1200Wboiler12meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
275C1200Wboiler12dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
276C1200Wboiler12gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
277C1200Wboiler12dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10692
278C1200Wboiler12nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
279C1200Wboiler12dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10712
280C1200Wboiler12dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
281C1200Wboiler12dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
282C1200Wboiler12dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
283C1200Wboiler12dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
284C1200Wboiler12dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
285C1200Wboiler12dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
286C1200Wboiler12dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
287C1200Wboiler12dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
288C1200Wboiler12dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
289C1200Wboiler12dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
290C1200Wboiler12dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
291C1200Wboiler12dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
292C1200Wboiler12dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
293C1200Wboiler12dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
294C1200Wboiler12dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
295C1200Wboiler12dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
296C1200Wboiler12dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
297C1200Wboiler12dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
298C1200Wboiler12dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
299C1200Wboiler12dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
300C1200Wboiler12dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
301C1200Wboiler12dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
302C1200Wboiler12dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
303C1200Wboiler12dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
304C1200Wboiler12dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
305C1200Wboiler12dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
306C1200Wboiler12dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
307C1200Wboiler12dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
308C1200Wboiler12dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
309C1200Wboiler12dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
310C1200Wboiler12dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
311C1200Wboiler12dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
312C1200Wboiler12dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
313C1200Wboiler12dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
314C1200Wboiler12dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
315C1200Wboiler12dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10631
316C1200Wboiler12dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10641
317C1200Wboiler12dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591652
318C1200Wboiler12dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591672
319C1200Wboiler12nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
320C1200Wboiler12nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
321C1200Wboiler12nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
322C1200Wboiler12dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
323BK13/BK15, Smartline, GB1*2boiler64resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
324BK13/BK15, Smartline, GB1*2boiler64heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
325BK13/BK15, Smartline, GB1*2boiler64heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
326BK13/BK15, Smartline, GB1*2boiler64tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
327BK13/BK15, Smartline, GB1*2boiler64selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
328BK13/BK15, Smartline, GB1*2boiler64heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
329BK13/BK15, Smartline, GB1*2boiler64outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
330BK13/BK15, Smartline, GB1*2boiler64curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
331BK13/BK15, Smartline, GB1*2boiler64rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
332BK13/BK15, Smartline, GB1*2boiler64switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
333BK13/BK15, Smartline, GB1*2boiler64syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
334BK13/BK15, Smartline, GB1*2boiler64boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
335BK13/BK15, Smartline, GB1*2boiler64headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
336BK13/BK15, Smartline, GB1*2boiler64exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
337BK13/BK15, Smartline, GB1*2boiler64burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
338BK13/BK15, Smartline, GB1*2boiler64burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
339BK13/BK15, Smartline, GB1*2boiler64flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
340BK13/BK15, Smartline, GB1*2boiler64fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
341BK13/BK15, Smartline, GB1*2boiler64ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
342BK13/BK15, Smartline, GB1*2boiler64oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
343BK13/BK15, Smartline, GB1*2boiler64burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
344BK13/BK15, Smartline, GB1*2boiler64burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
345BK13/BK15, Smartline, GB1*2boiler64burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
346BK13/BK15, Smartline, GB1*2boiler64absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
347BK13/BK15, Smartline, GB1*2boiler64heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
348BK13/BK15, Smartline, GB1*2boiler64boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
349BK13/BK15, Smartline, GB1*2boiler64boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
350BK13/BK15, Smartline, GB1*2boiler64boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
351BK13/BK15, Smartline, GB1*2boiler64boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
352BK13/BK15, Smartline, GB1*2boiler64curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
353BK13/BK15, Smartline, GB1*2boiler64curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
354BK13/BK15, Smartline, GB1*2boiler64curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
355BK13/BK15, Smartline, GB1*2boiler64summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
356BK13/BK15, Smartline, GB1*2boiler64nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
357BK13/BK15, Smartline, GB1*2boiler64nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
358BK13/BK15, Smartline, GB1*2boiler64heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
359BK13/BK15, Smartline, GB1*2boiler64heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
360BK13/BK15, Smartline, GB1*2boiler64heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
361BK13/BK15, Smartline, GB1*2boiler64pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
362BK13/BK15, Smartline, GB1*2boiler64pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
363BK13/BK15, Smartline, GB1*2boiler64pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
364BK13/BK15, Smartline, GB1*2boiler64pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
365BK13/BK15, Smartline, GB1*2boiler64pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
366BK13/BK15, Smartline, GB1*2boiler64pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
367BK13/BK15, Smartline, GB1*2boiler64selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
368BK13/BK15, Smartline, GB1*2boiler64curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
369BK13/BK15, Smartline, GB1*2boiler64burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
370BK13/BK15, Smartline, GB1*2boiler64burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
371BK13/BK15, Smartline, GB1*2boiler64burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
372BK13/BK15, Smartline, GB1*2boiler64heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
373BK13/BK15, Smartline, GB1*2boiler64heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
374BK13/BK15, Smartline, GB1*2boiler64ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
375BK13/BK15, Smartline, GB1*2boiler64lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
376BK13/BK15, Smartline, GB1*2boiler64servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
377BK13/BK15, Smartline, GB1*2boiler64servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
378BK13/BK15, Smartline, GB1*2boiler64maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
379BK13/BK15, Smartline, GB1*2boiler64maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
380BK13/BK15, Smartline, GB1*2boiler64maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
381BK13/BK15, Smartline, GB1*2boiler64maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
382BK13/BK15, Smartline, GB1*2boiler64emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
383BK13/BK15, Smartline, GB1*2boiler64emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
384BK13/BK15, Smartline, GB1*2boiler64pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
385BK13/BK15, Smartline, GB1*2boiler64pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
386BK13/BK15, Smartline, GB1*2boiler64pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
387BK13/BK15, Smartline, GB1*2boiler64pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
388BK13/BK15, Smartline, GB1*2boiler64meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
389BK13/BK15, Smartline, GB1*2boiler64dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
390BK13/BK15, Smartline, GB1*2boiler64gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
391BK13/BK15, Smartline, GB1*2boiler64dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10692
392BK13/BK15, Smartline, GB1*2boiler64nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
393BK13/BK15, Smartline, GB1*2boiler64dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10712
394BK13/BK15, Smartline, GB1*2boiler64dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
395BK13/BK15, Smartline, GB1*2boiler64dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
396BK13/BK15, Smartline, GB1*2boiler64dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
397BK13/BK15, Smartline, GB1*2boiler64dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
398BK13/BK15, Smartline, GB1*2boiler64dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
399BK13/BK15, Smartline, GB1*2boiler64dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
400BK13/BK15, Smartline, GB1*2boiler64dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
401BK13/BK15, Smartline, GB1*2boiler64dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
402BK13/BK15, Smartline, GB1*2boiler64dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
403BK13/BK15, Smartline, GB1*2boiler64dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
404BK13/BK15, Smartline, GB1*2boiler64dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
405BK13/BK15, Smartline, GB1*2boiler64dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
406BK13/BK15, Smartline, GB1*2boiler64dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
407BK13/BK15, Smartline, GB1*2boiler64dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
408BK13/BK15, Smartline, GB1*2boiler64dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
409BK13/BK15, Smartline, GB1*2boiler64dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
410BK13/BK15, Smartline, GB1*2boiler64dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
411BK13/BK15, Smartline, GB1*2boiler64dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
412BK13/BK15, Smartline, GB1*2boiler64dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
413BK13/BK15, Smartline, GB1*2boiler64dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
414BK13/BK15, Smartline, GB1*2boiler64dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
415BK13/BK15, Smartline, GB1*2boiler64dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
416BK13/BK15, Smartline, GB1*2boiler64dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
417BK13/BK15, Smartline, GB1*2boiler64dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
418BK13/BK15, Smartline, GB1*2boiler64dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
419BK13/BK15, Smartline, GB1*2boiler64dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
420BK13/BK15, Smartline, GB1*2boiler64dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
421BK13/BK15, Smartline, GB1*2boiler64dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
422BK13/BK15, Smartline, GB1*2boiler64dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
423BK13/BK15, Smartline, GB1*2boiler64dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
424BK13/BK15, Smartline, GB1*2boiler64dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
425BK13/BK15, Smartline, GB1*2boiler64dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
426BK13/BK15, Smartline, GB1*2boiler64dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
427BK13/BK15, Smartline, GB1*2boiler64dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
428BK13/BK15, Smartline, GB1*2boiler64dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
429BK13/BK15, Smartline, GB1*2boiler64dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10631
430BK13/BK15, Smartline, GB1*2boiler64dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10641
431BK13/BK15, Smartline, GB1*2boiler64dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591652
432BK13/BK15, Smartline, GB1*2boiler64dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591672
433BK13/BK15, Smartline, GB1*2boiler64nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
434BK13/BK15, Smartline, GB1*2boiler64nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
435BK13/BK15, Smartline, GB1*2boiler64nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
436BK13/BK15, Smartline, GB1*2boiler64dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
437Logano GB1*5, Logamatic MC10boiler72resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
438Logano GB1*5, Logamatic MC10boiler72heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
439Logano GB1*5, Logamatic MC10boiler72heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
440Logano GB1*5, Logamatic MC10boiler72tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
441Logano GB1*5, Logamatic MC10boiler72selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
442Logano GB1*5, Logamatic MC10boiler72heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
443Logano GB1*5, Logamatic MC10boiler72outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
444Logano GB1*5, Logamatic MC10boiler72curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
445Logano GB1*5, Logamatic MC10boiler72rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
446Logano GB1*5, Logamatic MC10boiler72switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
447Logano GB1*5, Logamatic MC10boiler72syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
448Logano GB1*5, Logamatic MC10boiler72boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
449Logano GB1*5, Logamatic MC10boiler72headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
450Logano GB1*5, Logamatic MC10boiler72exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
451Logano GB1*5, Logamatic MC10boiler72burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
452Logano GB1*5, Logamatic MC10boiler72burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
453Logano GB1*5, Logamatic MC10boiler72flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
454Logano GB1*5, Logamatic MC10boiler72fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
455Logano GB1*5, Logamatic MC10boiler72ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
456Logano GB1*5, Logamatic MC10boiler72oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
457Logano GB1*5, Logamatic MC10boiler72burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
458Logano GB1*5, Logamatic MC10boiler72burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
459Logano GB1*5, Logamatic MC10boiler72burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
460Logano GB1*5, Logamatic MC10boiler72absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
461Logano GB1*5, Logamatic MC10boiler72heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
462Logano GB1*5, Logamatic MC10boiler72boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
463Logano GB1*5, Logamatic MC10boiler72boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
464Logano GB1*5, Logamatic MC10boiler72boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
465Logano GB1*5, Logamatic MC10boiler72boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
466Logano GB1*5, Logamatic MC10boiler72curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
467Logano GB1*5, Logamatic MC10boiler72curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
468Logano GB1*5, Logamatic MC10boiler72curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
469Logano GB1*5, Logamatic MC10boiler72summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
470Logano GB1*5, Logamatic MC10boiler72nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
471Logano GB1*5, Logamatic MC10boiler72nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
472Logano GB1*5, Logamatic MC10boiler72heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
473Logano GB1*5, Logamatic MC10boiler72heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
474Logano GB1*5, Logamatic MC10boiler72heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
475Logano GB1*5, Logamatic MC10boiler72pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
476Logano GB1*5, Logamatic MC10boiler72pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
477Logano GB1*5, Logamatic MC10boiler72pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
478Logano GB1*5, Logamatic MC10boiler72pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
479Logano GB1*5, Logamatic MC10boiler72pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
480Logano GB1*5, Logamatic MC10boiler72pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
481Logano GB1*5, Logamatic MC10boiler72selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
482Logano GB1*5, Logamatic MC10boiler72curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
483Logano GB1*5, Logamatic MC10boiler72burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
484Logano GB1*5, Logamatic MC10boiler72burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
485Logano GB1*5, Logamatic MC10boiler72burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
486Logano GB1*5, Logamatic MC10boiler72heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
487Logano GB1*5, Logamatic MC10boiler72heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
488Logano GB1*5, Logamatic MC10boiler72ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
489Logano GB1*5, Logamatic MC10boiler72lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
490Logano GB1*5, Logamatic MC10boiler72servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
491Logano GB1*5, Logamatic MC10boiler72servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
492Logano GB1*5, Logamatic MC10boiler72maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
493Logano GB1*5, Logamatic MC10boiler72maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
494Logano GB1*5, Logamatic MC10boiler72maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
495Logano GB1*5, Logamatic MC10boiler72maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
496Logano GB1*5, Logamatic MC10boiler72emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
497Logano GB1*5, Logamatic MC10boiler72emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
498Logano GB1*5, Logamatic MC10boiler72pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
499Logano GB1*5, Logamatic MC10boiler72pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
500Logano GB1*5, Logamatic MC10boiler72pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
501Logano GB1*5, Logamatic MC10boiler72pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
502Logano GB1*5, Logamatic MC10boiler72meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
503Logano GB1*5, Logamatic MC10boiler72dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
504Logano GB1*5, Logamatic MC10boiler72gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
505Logano GB1*5, Logamatic MC10boiler72dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10692
506Logano GB1*5, Logamatic MC10boiler72nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
507Logano GB1*5, Logamatic MC10boiler72dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10712
508Logano GB1*5, Logamatic MC10boiler72dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
509Logano GB1*5, Logamatic MC10boiler72dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
510Logano GB1*5, Logamatic MC10boiler72dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
511Logano GB1*5, Logamatic MC10boiler72dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
512Logano GB1*5, Logamatic MC10boiler72dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
513Logano GB1*5, Logamatic MC10boiler72dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
514Logano GB1*5, Logamatic MC10boiler72dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
515Logano GB1*5, Logamatic MC10boiler72dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
516Logano GB1*5, Logamatic MC10boiler72dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
517Logano GB1*5, Logamatic MC10boiler72dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
518Logano GB1*5, Logamatic MC10boiler72dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
519Logano GB1*5, Logamatic MC10boiler72dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
520Logano GB1*5, Logamatic MC10boiler72dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
521Logano GB1*5, Logamatic MC10boiler72dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
522Logano GB1*5, Logamatic MC10boiler72dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
523Logano GB1*5, Logamatic MC10boiler72dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
524Logano GB1*5, Logamatic MC10boiler72dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
525Logano GB1*5, Logamatic MC10boiler72dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
526Logano GB1*5, Logamatic MC10boiler72dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
527Logano GB1*5, Logamatic MC10boiler72dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
528Logano GB1*5, Logamatic MC10boiler72dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
529Logano GB1*5, Logamatic MC10boiler72dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
530Logano GB1*5, Logamatic MC10boiler72dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
531Logano GB1*5, Logamatic MC10boiler72dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
532Logano GB1*5, Logamatic MC10boiler72dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
533Logano GB1*5, Logamatic MC10boiler72dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
534Logano GB1*5, Logamatic MC10boiler72dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
535Logano GB1*5, Logamatic MC10boiler72dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
536Logano GB1*5, Logamatic MC10boiler72dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
537Logano GB1*5, Logamatic MC10boiler72dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
538Logano GB1*5, Logamatic MC10boiler72dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
539Logano GB1*5, Logamatic MC10boiler72dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
540Logano GB1*5, Logamatic MC10boiler72dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
541Logano GB1*5, Logamatic MC10boiler72dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
542Logano GB1*5, Logamatic MC10boiler72dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
543Logano GB1*5, Logamatic MC10boiler72dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10631
544Logano GB1*5, Logamatic MC10boiler72dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10641
545Logano GB1*5, Logamatic MC10boiler72dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591652
546Logano GB1*5, Logamatic MC10boiler72dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591672
547Logano GB1*5, Logamatic MC10boiler72nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
548Logano GB1*5, Logamatic MC10boiler72nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
549Logano GB1*5, Logamatic MC10boiler72nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
550Logano GB1*5, Logamatic MC10boiler72dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
551Cascade CM10boiler81resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
552Cascade CM10boiler81heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
553Cascade CM10boiler81heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
554Cascade CM10boiler81tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
555Cascade CM10boiler81selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
556Cascade CM10boiler81heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
557Cascade CM10boiler81outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
558Cascade CM10boiler81curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
559Cascade CM10boiler81rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
560Cascade CM10boiler81switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
561Cascade CM10boiler81syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
562Cascade CM10boiler81boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
563Cascade CM10boiler81headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
564Cascade CM10boiler81exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
565Cascade CM10boiler81burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
566Cascade CM10boiler81burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
567Cascade CM10boiler81flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
568Cascade CM10boiler81fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
569Cascade CM10boiler81ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
570Cascade CM10boiler81oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
571Cascade CM10boiler81burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
572Cascade CM10boiler81burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
573Cascade CM10boiler81burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
574Cascade CM10boiler81absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
575Cascade CM10boiler81heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
576Cascade CM10boiler81boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
577Cascade CM10boiler81boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
578Cascade CM10boiler81boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
579Cascade CM10boiler81boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
580Cascade CM10boiler81curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
581Cascade CM10boiler81curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
582Cascade CM10boiler81curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
583Cascade CM10boiler81summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
584Cascade CM10boiler81nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
585Cascade CM10boiler81nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
586Cascade CM10boiler81heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
587Cascade CM10boiler81heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
588Cascade CM10boiler81heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
589Cascade CM10boiler81pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
590Cascade CM10boiler81pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
591Cascade CM10boiler81pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
592Cascade CM10boiler81pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
593Cascade CM10boiler81pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
594Cascade CM10boiler81pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
595Cascade CM10boiler81selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
596Cascade CM10boiler81curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
597Cascade CM10boiler81burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
598Cascade CM10boiler81burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
599Cascade CM10boiler81burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
600Cascade CM10boiler81heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
601Cascade CM10boiler81heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
602Cascade CM10boiler81ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
603Cascade CM10boiler81lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
604Cascade CM10boiler81servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
605Cascade CM10boiler81servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
606Cascade CM10boiler81maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
607Cascade CM10boiler81maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
608Cascade CM10boiler81maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
609Cascade CM10boiler81maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
610Cascade CM10boiler81emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
611Cascade CM10boiler81emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
612Cascade CM10boiler81pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
613Cascade CM10boiler81pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
614Cascade CM10boiler81pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
615Cascade CM10boiler81pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
616Cascade CM10boiler81meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
617Cascade CM10boiler81dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
618Cascade CM10boiler81gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
619Cascade CM10boiler81dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10692
620Cascade CM10boiler81nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
621Cascade CM10boiler81dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10712
622Cascade CM10boiler81dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
623Cascade CM10boiler81dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
624Cascade CM10boiler81dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
625Cascade CM10boiler81dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
626Cascade CM10boiler81dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
627Cascade CM10boiler81dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
628Cascade CM10boiler81dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
629Cascade CM10boiler81dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
630Cascade CM10boiler81dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
631Cascade CM10boiler81dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
632Cascade CM10boiler81dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
633Cascade CM10boiler81dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
634Cascade CM10boiler81dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
635Cascade CM10boiler81dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
636Cascade CM10boiler81dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
637Cascade CM10boiler81dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
638Cascade CM10boiler81dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
639Cascade CM10boiler81dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
640Cascade CM10boiler81dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
641Cascade CM10boiler81dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
642Cascade CM10boiler81dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
643Cascade CM10boiler81dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
644Cascade CM10boiler81dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
645Cascade CM10boiler81dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
646Cascade CM10boiler81dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
647Cascade CM10boiler81dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
648Cascade CM10boiler81dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
649Cascade CM10boiler81dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
650Cascade CM10boiler81dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
651Cascade CM10boiler81dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
652Cascade CM10boiler81dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
653Cascade CM10boiler81dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
654Cascade CM10boiler81dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
655Cascade CM10boiler81dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
656Cascade CM10boiler81dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
657Cascade CM10boiler81dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10631
658Cascade CM10boiler81dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10641
659Cascade CM10boiler81dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591652
660Cascade CM10boiler81dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591672
661Cascade CM10boiler81nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
662Cascade CM10boiler81nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
663Cascade CM10boiler81nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
664Cascade CM10boiler81dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
665Logamax Plus GB022boiler84resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
666Logamax Plus GB022boiler84heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
667Logamax Plus GB022boiler84heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
668Logamax Plus GB022boiler84tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
669Logamax Plus GB022boiler84selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
670Logamax Plus GB022boiler84heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
671Logamax Plus GB022boiler84outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
672Logamax Plus GB022boiler84curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
673Logamax Plus GB022boiler84rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
674Logamax Plus GB022boiler84switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
675Logamax Plus GB022boiler84syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
676Logamax Plus GB022boiler84boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
677Logamax Plus GB022boiler84headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
678Logamax Plus GB022boiler84exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
679Logamax Plus GB022boiler84burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
680Logamax Plus GB022boiler84burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
681Logamax Plus GB022boiler84flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
682Logamax Plus GB022boiler84fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
683Logamax Plus GB022boiler84ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
684Logamax Plus GB022boiler84oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
685Logamax Plus GB022boiler84burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
686Logamax Plus GB022boiler84burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
687Logamax Plus GB022boiler84burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
688Logamax Plus GB022boiler84absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
689Logamax Plus GB022boiler84heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
690Logamax Plus GB022boiler84boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
691Logamax Plus GB022boiler84boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
692Logamax Plus GB022boiler84boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
693Logamax Plus GB022boiler84boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
694Logamax Plus GB022boiler84curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
695Logamax Plus GB022boiler84curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
696Logamax Plus GB022boiler84curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
697Logamax Plus GB022boiler84summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
698Logamax Plus GB022boiler84nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
699Logamax Plus GB022boiler84nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
700Logamax Plus GB022boiler84heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
701Logamax Plus GB022boiler84heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
702Logamax Plus GB022boiler84heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
703Logamax Plus GB022boiler84pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
704Logamax Plus GB022boiler84pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
705Logamax Plus GB022boiler84pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
706Logamax Plus GB022boiler84pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
707Logamax Plus GB022boiler84pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
708Logamax Plus GB022boiler84pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
709Logamax Plus GB022boiler84selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
710Logamax Plus GB022boiler84curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
711Logamax Plus GB022boiler84burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
712Logamax Plus GB022boiler84burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
713Logamax Plus GB022boiler84burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
714Logamax Plus GB022boiler84heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
715Logamax Plus GB022boiler84heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
716Logamax Plus GB022boiler84ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
717Logamax Plus GB022boiler84lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
718Logamax Plus GB022boiler84servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
719Logamax Plus GB022boiler84servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
720Logamax Plus GB022boiler84maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
721Logamax Plus GB022boiler84maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
722Logamax Plus GB022boiler84maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
723Logamax Plus GB022boiler84maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
724Logamax Plus GB022boiler84emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
725Logamax Plus GB022boiler84emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
726Logamax Plus GB022boiler84pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
727Logamax Plus GB022boiler84pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
728Logamax Plus GB022boiler84pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
729Logamax Plus GB022boiler84pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
730Logamax Plus GB022boiler84meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
731Logamax Plus GB022boiler84dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
732Logamax Plus GB022boiler84gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
733Logamax Plus GB022boiler84dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10692
734Logamax Plus GB022boiler84nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
735Logamax Plus GB022boiler84dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10712
736Logamax Plus GB022boiler84dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
737Logamax Plus GB022boiler84dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
738Logamax Plus GB022boiler84dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
739Logamax Plus GB022boiler84dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
740Logamax Plus GB022boiler84dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
741Logamax Plus GB022boiler84dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
742Logamax Plus GB022boiler84dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
743Logamax Plus GB022boiler84dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
744Logamax Plus GB022boiler84dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
745Logamax Plus GB022boiler84dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
746Logamax Plus GB022boiler84dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
747Logamax Plus GB022boiler84dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
748Logamax Plus GB022boiler84dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
749Logamax Plus GB022boiler84dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
750Logamax Plus GB022boiler84dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
751Logamax Plus GB022boiler84dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
752Logamax Plus GB022boiler84dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
753Logamax Plus GB022boiler84dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
754Logamax Plus GB022boiler84dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
755Logamax Plus GB022boiler84dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
756Logamax Plus GB022boiler84dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
757Logamax Plus GB022boiler84dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
758Logamax Plus GB022boiler84dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
759Logamax Plus GB022boiler84dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
760Logamax Plus GB022boiler84dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
761Logamax Plus GB022boiler84dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
762Logamax Plus GB022boiler84dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
763Logamax Plus GB022boiler84dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
764Logamax Plus GB022boiler84dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
765Logamax Plus GB022boiler84dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
766Logamax Plus GB022boiler84dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
767Logamax Plus GB022boiler84dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
768Logamax Plus GB022boiler84dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
769Logamax Plus GB022boiler84dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
770Logamax Plus GB022boiler84dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
771Logamax Plus GB022boiler84dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10631
772Logamax Plus GB022boiler84dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10641
773Logamax Plus GB022boiler84dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591652
774Logamax Plus GB022boiler84dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591672
775Logamax Plus GB022boiler84nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
776Logamax Plus GB022boiler84nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
777Logamax Plus GB022boiler84nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
778Logamax Plus GB022boiler84dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
779Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
780Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
781Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
782Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
783Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
784Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
785Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
786Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
787Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
788Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
789Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
790Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
791Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
792Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
793Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
794Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
795Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
796Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
797Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
798Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
799Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
800Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
801Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
802Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
803Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
804Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
805Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
806Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
807Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
808Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
809Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
810Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
811Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
812Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
813Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
814Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
815Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
816Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
817Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
818Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
819Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
820Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
821Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
822Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
823Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
824Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
825Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
826Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
827Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
828Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
829Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
830Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
831Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
832Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
833Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
834Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
835Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
836Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
837Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
838Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
839Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
840Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
841Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
842Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
843Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
844Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
845Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
846Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
847Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10692
848Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
849Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10712
850Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
851Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
852Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
853Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
854Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
855Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
856Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
857Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
858Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
859Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
860Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
861Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
862Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
863Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
864Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
865Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
866Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
867Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
868Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
869Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
870Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
871Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
872Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
873Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
874Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
875Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
876Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
877Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
878Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
879Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
880Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
881Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
882Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
883Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
884Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
885Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10631
886Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10641
887Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591652
888Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591672
889Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
890Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
891Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
892Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
893Topline, GB162boiler115resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
894Topline, GB162boiler115heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
895Topline, GB162boiler115heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
896Topline, GB162boiler115tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
897Topline, GB162boiler115selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
898Topline, GB162boiler115heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
899Topline, GB162boiler115outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
900Topline, GB162boiler115curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
901Topline, GB162boiler115rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
902Topline, GB162boiler115switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
903Topline, GB162boiler115syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
904Topline, GB162boiler115boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
905Topline, GB162boiler115headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
906Topline, GB162boiler115exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
907Topline, GB162boiler115burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
908Topline, GB162boiler115burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
909Topline, GB162boiler115flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
910Topline, GB162boiler115fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
911Topline, GB162boiler115ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
912Topline, GB162boiler115oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
913Topline, GB162boiler115burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
914Topline, GB162boiler115burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
915Topline, GB162boiler115burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
916Topline, GB162boiler115absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
917Topline, GB162boiler115heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
918Topline, GB162boiler115boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
919Topline, GB162boiler115boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
920Topline, GB162boiler115boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
921Topline, GB162boiler115boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
922Topline, GB162boiler115curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
923Topline, GB162boiler115curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
924Topline, GB162boiler115curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
925Topline, GB162boiler115summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
926Topline, GB162boiler115nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
927Topline, GB162boiler115nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
928Topline, GB162boiler115heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
929Topline, GB162boiler115heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
930Topline, GB162boiler115heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
931Topline, GB162boiler115pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
932Topline, GB162boiler115pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
933Topline, GB162boiler115pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
934Topline, GB162boiler115pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
935Topline, GB162boiler115pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
936Topline, GB162boiler115pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
937Topline, GB162boiler115selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
938Topline, GB162boiler115curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
939Topline, GB162boiler115burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
940Topline, GB162boiler115burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
941Topline, GB162boiler115burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
942Topline, GB162boiler115heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
943Topline, GB162boiler115heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
944Topline, GB162boiler115ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
945Topline, GB162boiler115lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
946Topline, GB162boiler115servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
947Topline, GB162boiler115servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
948Topline, GB162boiler115maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
949Topline, GB162boiler115maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
950Topline, GB162boiler115maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
951Topline, GB162boiler115maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
952Topline, GB162boiler115emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
953Topline, GB162boiler115emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
954Topline, GB162boiler115pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
955Topline, GB162boiler115pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
956Topline, GB162boiler115pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
957Topline, GB162boiler115pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
958Topline, GB162boiler115meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
959Topline, GB162boiler115dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
960Topline, GB162boiler115gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
961Topline, GB162boiler115dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10692
962Topline, GB162boiler115nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
963Topline, GB162boiler115dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10712
964Topline, GB162boiler115dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
965Topline, GB162boiler115dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
966Topline, GB162boiler115dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
967Topline, GB162boiler115dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
968Topline, GB162boiler115dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
969Topline, GB162boiler115dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
970Topline, GB162boiler115dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
971Topline, GB162boiler115dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
972Topline, GB162boiler115dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
973Topline, GB162boiler115dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
974Topline, GB162boiler115dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
975Topline, GB162boiler115dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
976Topline, GB162boiler115dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
977Topline, GB162boiler115dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
978Topline, GB162boiler115dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
979Topline, GB162boiler115dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
980Topline, GB162boiler115dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
981Topline, GB162boiler115dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
982Topline, GB162boiler115dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
983Topline, GB162boiler115dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
984Topline, GB162boiler115dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
985Topline, GB162boiler115dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
986Topline, GB162boiler115dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
987Topline, GB162boiler115dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
988Topline, GB162boiler115dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
989Topline, GB162boiler115dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
990Topline, GB162boiler115dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
991Topline, GB162boiler115dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
992Topline, GB162boiler115dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
993Topline, GB162boiler115dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
994Topline, GB162boiler115dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
995Topline, GB162boiler115dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
996Topline, GB162boiler115dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
997Topline, GB162boiler115dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
998Topline, GB162boiler115dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
999Topline, GB162boiler115dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10631
1000Topline, GB162boiler115dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10641
1001Topline, GB162boiler115dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591652
1002Topline, GB162boiler115dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591672
1003Topline, GB162boiler115nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1004Topline, GB162boiler115nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1005Topline, GB162boiler115nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1006Topline, GB162boiler115dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1007Cascade MCM10boiler121resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1008Cascade MCM10boiler121heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1009Cascade MCM10boiler121heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1010Cascade MCM10boiler121tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1011Cascade MCM10boiler121selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1012Cascade MCM10boiler121heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1013Cascade MCM10boiler121outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1014Cascade MCM10boiler121curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1015Cascade MCM10boiler121rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1016Cascade MCM10boiler121switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1017Cascade MCM10boiler121syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1018Cascade MCM10boiler121boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1019Cascade MCM10boiler121headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1020Cascade MCM10boiler121exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1021Cascade MCM10boiler121burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1022Cascade MCM10boiler121burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1023Cascade MCM10boiler121flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1024Cascade MCM10boiler121fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1025Cascade MCM10boiler121ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1026Cascade MCM10boiler121oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1027Cascade MCM10boiler121burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1028Cascade MCM10boiler121burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1029Cascade MCM10boiler121burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1030Cascade MCM10boiler121absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1031Cascade MCM10boiler121heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1032Cascade MCM10boiler121boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1033Cascade MCM10boiler121boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1034Cascade MCM10boiler121boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1035Cascade MCM10boiler121boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1036Cascade MCM10boiler121curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1037Cascade MCM10boiler121curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1038Cascade MCM10boiler121curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1039Cascade MCM10boiler121summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1040Cascade MCM10boiler121nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1041Cascade MCM10boiler121nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1042Cascade MCM10boiler121heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1043Cascade MCM10boiler121heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1044Cascade MCM10boiler121heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1045Cascade MCM10boiler121pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1046Cascade MCM10boiler121pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1047Cascade MCM10boiler121pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1048Cascade MCM10boiler121pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1049Cascade MCM10boiler121pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1050Cascade MCM10boiler121pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1051Cascade MCM10boiler121selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1052Cascade MCM10boiler121curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1053Cascade MCM10boiler121burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1054Cascade MCM10boiler121burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1055Cascade MCM10boiler121burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1056Cascade MCM10boiler121heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1057Cascade MCM10boiler121heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1058Cascade MCM10boiler121ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1059Cascade MCM10boiler121lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1060Cascade MCM10boiler121servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1061Cascade MCM10boiler121servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1062Cascade MCM10boiler121maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1063Cascade MCM10boiler121maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1064Cascade MCM10boiler121maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1065Cascade MCM10boiler121maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1066Cascade MCM10boiler121emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1067Cascade MCM10boiler121emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1068Cascade MCM10boiler121pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1069Cascade MCM10boiler121pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1070Cascade MCM10boiler121pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1071Cascade MCM10boiler121pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1072Cascade MCM10boiler121meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1073Cascade MCM10boiler121dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1074Cascade MCM10boiler121gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1075Cascade MCM10boiler121dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10692
1076Cascade MCM10boiler121nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1077Cascade MCM10boiler121dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10712
1078Cascade MCM10boiler121dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1079Cascade MCM10boiler121dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1080Cascade MCM10boiler121dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1081Cascade MCM10boiler121dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1082Cascade MCM10boiler121dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1083Cascade MCM10boiler121dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1084Cascade MCM10boiler121dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1085Cascade MCM10boiler121dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1086Cascade MCM10boiler121dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1087Cascade MCM10boiler121dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1088Cascade MCM10boiler121dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1089Cascade MCM10boiler121dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1090Cascade MCM10boiler121dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1091Cascade MCM10boiler121dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1092Cascade MCM10boiler121dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1093Cascade MCM10boiler121dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1094Cascade MCM10boiler121dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1095Cascade MCM10boiler121dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1096Cascade MCM10boiler121dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1097Cascade MCM10boiler121dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1098Cascade MCM10boiler121dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1099Cascade MCM10boiler121dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1100Cascade MCM10boiler121dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1101Cascade MCM10boiler121dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1102Cascade MCM10boiler121dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1103Cascade MCM10boiler121dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1104Cascade MCM10boiler121dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1105Cascade MCM10boiler121dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1106Cascade MCM10boiler121dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1107Cascade MCM10boiler121dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1108Cascade MCM10boiler121dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1109Cascade MCM10boiler121dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1110Cascade MCM10boiler121dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1111Cascade MCM10boiler121dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1112Cascade MCM10boiler121dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1113Cascade MCM10boiler121dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10631
1114Cascade MCM10boiler121dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10641
1115Cascade MCM10boiler121dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591652
1116Cascade MCM10boiler121dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591672
1117Cascade MCM10boiler121nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1118Cascade MCM10boiler121nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1119Cascade MCM10boiler121nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1120Cascade MCM10boiler121dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1121Prolineboiler122resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1122Prolineboiler122heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1123Prolineboiler122heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1124Prolineboiler122tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1125Prolineboiler122selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1126Prolineboiler122heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1127Prolineboiler122outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1128Prolineboiler122curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1129Prolineboiler122rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1130Prolineboiler122switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1131Prolineboiler122syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1132Prolineboiler122boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1133Prolineboiler122headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1134Prolineboiler122exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1135Prolineboiler122burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1136Prolineboiler122burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1137Prolineboiler122flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1138Prolineboiler122fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1139Prolineboiler122ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1140Prolineboiler122oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1141Prolineboiler122burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1142Prolineboiler122burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1143Prolineboiler122burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1144Prolineboiler122absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1145Prolineboiler122heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1146Prolineboiler122boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1147Prolineboiler122boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1148Prolineboiler122boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1149Prolineboiler122boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1150Prolineboiler122curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1151Prolineboiler122curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1152Prolineboiler122curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1153Prolineboiler122summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1154Prolineboiler122nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1155Prolineboiler122nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1156Prolineboiler122heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1157Prolineboiler122heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1158Prolineboiler122heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1159Prolineboiler122pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1160Prolineboiler122pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1161Prolineboiler122pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1162Prolineboiler122pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1163Prolineboiler122pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1164Prolineboiler122pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1165Prolineboiler122selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1166Prolineboiler122curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1167Prolineboiler122burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1168Prolineboiler122burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1169Prolineboiler122burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1170Prolineboiler122heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1171Prolineboiler122heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1172Prolineboiler122ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1173Prolineboiler122lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1174Prolineboiler122servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1175Prolineboiler122servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1176Prolineboiler122maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1177Prolineboiler122maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1178Prolineboiler122maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1179Prolineboiler122maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1180Prolineboiler122emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1181Prolineboiler122emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1182Prolineboiler122pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1183Prolineboiler122pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1184Prolineboiler122pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1185Prolineboiler122pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1186Prolineboiler122meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1187Prolineboiler122dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1188Prolineboiler122gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1189Prolineboiler122dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10692
1190Prolineboiler122nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1191Prolineboiler122dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10712
1192Prolineboiler122dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1193Prolineboiler122dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1194Prolineboiler122dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1195Prolineboiler122dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1196Prolineboiler122dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1197Prolineboiler122dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1198Prolineboiler122dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1199Prolineboiler122dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1200Prolineboiler122dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1201Prolineboiler122dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1202Prolineboiler122dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1203Prolineboiler122dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1204Prolineboiler122dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1205Prolineboiler122dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1206Prolineboiler122dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1207Prolineboiler122dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1208Prolineboiler122dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1209Prolineboiler122dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1210Prolineboiler122dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1211Prolineboiler122dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1212Prolineboiler122dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1213Prolineboiler122dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1214Prolineboiler122dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1215Prolineboiler122dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1216Prolineboiler122dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1217Prolineboiler122dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1218Prolineboiler122dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1219Prolineboiler122dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1220Prolineboiler122dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1221Prolineboiler122dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1222Prolineboiler122dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1223Prolineboiler122dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1224Prolineboiler122dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1225Prolineboiler122dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1226Prolineboiler122dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1227Prolineboiler122dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10631
1228Prolineboiler122dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10641
1229Prolineboiler122dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591652
1230Prolineboiler122dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591672
1231Prolineboiler122nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1232Prolineboiler122nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1233Prolineboiler122nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1234Prolineboiler122dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1235GB*72, Trendline, Cerapur, Greenstar Siboiler123resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1236GB*72, Trendline, Cerapur, Greenstar Siboiler123heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1237GB*72, Trendline, Cerapur, Greenstar Siboiler123heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1238GB*72, Trendline, Cerapur, Greenstar Siboiler123tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1239GB*72, Trendline, Cerapur, Greenstar Siboiler123selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1240GB*72, Trendline, Cerapur, Greenstar Siboiler123heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1241GB*72, Trendline, Cerapur, Greenstar Siboiler123outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1242GB*72, Trendline, Cerapur, Greenstar Siboiler123curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1243GB*72, Trendline, Cerapur, Greenstar Siboiler123rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1244GB*72, Trendline, Cerapur, Greenstar Siboiler123switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1245GB*72, Trendline, Cerapur, Greenstar Siboiler123syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1246GB*72, Trendline, Cerapur, Greenstar Siboiler123boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1247GB*72, Trendline, Cerapur, Greenstar Siboiler123headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1248GB*72, Trendline, Cerapur, Greenstar Siboiler123exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1249GB*72, Trendline, Cerapur, Greenstar Siboiler123burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1250GB*72, Trendline, Cerapur, Greenstar Siboiler123burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1251GB*72, Trendline, Cerapur, Greenstar Siboiler123flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1252GB*72, Trendline, Cerapur, Greenstar Siboiler123fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1253GB*72, Trendline, Cerapur, Greenstar Siboiler123ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1254GB*72, Trendline, Cerapur, Greenstar Siboiler123oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1255GB*72, Trendline, Cerapur, Greenstar Siboiler123burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1256GB*72, Trendline, Cerapur, Greenstar Siboiler123burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1257GB*72, Trendline, Cerapur, Greenstar Siboiler123burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1258GB*72, Trendline, Cerapur, Greenstar Siboiler123absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1259GB*72, Trendline, Cerapur, Greenstar Siboiler123heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1260GB*72, Trendline, Cerapur, Greenstar Siboiler123boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1261GB*72, Trendline, Cerapur, Greenstar Siboiler123boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1262GB*72, Trendline, Cerapur, Greenstar Siboiler123boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1263GB*72, Trendline, Cerapur, Greenstar Siboiler123boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1264GB*72, Trendline, Cerapur, Greenstar Siboiler123curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1265GB*72, Trendline, Cerapur, Greenstar Siboiler123curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1266GB*72, Trendline, Cerapur, Greenstar Siboiler123curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1267GB*72, Trendline, Cerapur, Greenstar Siboiler123summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1268GB*72, Trendline, Cerapur, Greenstar Siboiler123nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1269GB*72, Trendline, Cerapur, Greenstar Siboiler123nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1270GB*72, Trendline, Cerapur, Greenstar Siboiler123heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1271GB*72, Trendline, Cerapur, Greenstar Siboiler123heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1272GB*72, Trendline, Cerapur, Greenstar Siboiler123heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1273GB*72, Trendline, Cerapur, Greenstar Siboiler123pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1274GB*72, Trendline, Cerapur, Greenstar Siboiler123pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1275GB*72, Trendline, Cerapur, Greenstar Siboiler123pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1276GB*72, Trendline, Cerapur, Greenstar Siboiler123pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1277GB*72, Trendline, Cerapur, Greenstar Siboiler123pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1278GB*72, Trendline, Cerapur, Greenstar Siboiler123pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1279GB*72, Trendline, Cerapur, Greenstar Siboiler123selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1280GB*72, Trendline, Cerapur, Greenstar Siboiler123curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1281GB*72, Trendline, Cerapur, Greenstar Siboiler123burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1282GB*72, Trendline, Cerapur, Greenstar Siboiler123burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1283GB*72, Trendline, Cerapur, Greenstar Siboiler123burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1284GB*72, Trendline, Cerapur, Greenstar Siboiler123heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1285GB*72, Trendline, Cerapur, Greenstar Siboiler123heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1286GB*72, Trendline, Cerapur, Greenstar Siboiler123ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1287GB*72, Trendline, Cerapur, Greenstar Siboiler123lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1288GB*72, Trendline, Cerapur, Greenstar Siboiler123servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1289GB*72, Trendline, Cerapur, Greenstar Siboiler123servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1290GB*72, Trendline, Cerapur, Greenstar Siboiler123maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1291GB*72, Trendline, Cerapur, Greenstar Siboiler123maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1292GB*72, Trendline, Cerapur, Greenstar Siboiler123maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1293GB*72, Trendline, Cerapur, Greenstar Siboiler123maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1294GB*72, Trendline, Cerapur, Greenstar Siboiler123emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1295GB*72, Trendline, Cerapur, Greenstar Siboiler123emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1296GB*72, Trendline, Cerapur, Greenstar Siboiler123pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1297GB*72, Trendline, Cerapur, Greenstar Siboiler123pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1298GB*72, Trendline, Cerapur, Greenstar Siboiler123pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1299GB*72, Trendline, Cerapur, Greenstar Siboiler123pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1300GB*72, Trendline, Cerapur, Greenstar Siboiler123meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1301GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1302GB*72, Trendline, Cerapur, Greenstar Siboiler123gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1303GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10692
1304GB*72, Trendline, Cerapur, Greenstar Siboiler123nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1305GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10712
1306GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1307GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1308GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1309GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1310GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1311GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1312GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1313GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1314GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1315GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1316GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1317GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1318GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1319GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1320GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1321GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1322GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1323GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1324GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1325GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1326GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1327GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1328GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1329GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1330GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1331GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1332GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1333GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1334GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1335GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1336GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1337GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1338GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1339GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1340GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1341GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10631
1342GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10641
1343GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591652
1344GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591672
1345GB*72, Trendline, Cerapur, Greenstar Siboiler123nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1346GB*72, Trendline, Cerapur, Greenstar Siboiler123nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1347GB*72, Trendline, Cerapur, Greenstar Siboiler123nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1348GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1349GB212boiler131resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1350GB212boiler131heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1351GB212boiler131heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1352GB212boiler131tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1353GB212boiler131selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1354GB212boiler131heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1355GB212boiler131outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1356GB212boiler131curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1357GB212boiler131rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1358GB212boiler131switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1359GB212boiler131syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1360GB212boiler131boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1361GB212boiler131headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1362GB212boiler131exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1363GB212boiler131burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1364GB212boiler131burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1365GB212boiler131flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1366GB212boiler131fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1367GB212boiler131ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1368GB212boiler131oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1369GB212boiler131burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1370GB212boiler131burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1371GB212boiler131burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1372GB212boiler131absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1373GB212boiler131heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1374GB212boiler131boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1375GB212boiler131boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1376GB212boiler131boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1377GB212boiler131boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1378GB212boiler131curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1379GB212boiler131curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1380GB212boiler131curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1381GB212boiler131summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1382GB212boiler131nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1383GB212boiler131nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1384GB212boiler131heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1385GB212boiler131heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1386GB212boiler131heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1387GB212boiler131pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1388GB212boiler131pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1389GB212boiler131pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1390GB212boiler131pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1391GB212boiler131pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1392GB212boiler131pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1393GB212boiler131selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1394GB212boiler131curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1395GB212boiler131burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1396GB212boiler131burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1397GB212boiler131burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1398GB212boiler131heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1399GB212boiler131heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1400GB212boiler131ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1401GB212boiler131lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1402GB212boiler131servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1403GB212boiler131servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1404GB212boiler131maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1405GB212boiler131maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1406GB212boiler131maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1407GB212boiler131maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1408GB212boiler131emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1409GB212boiler131emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1410GB212boiler131pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1411GB212boiler131pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1412GB212boiler131pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1413GB212boiler131pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1414GB212boiler131meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1415GB212boiler131dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1416GB212boiler131gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1417GB212boiler131dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10692
1418GB212boiler131nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1419GB212boiler131dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10712
1420GB212boiler131dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1421GB212boiler131dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1422GB212boiler131dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1423GB212boiler131dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1424GB212boiler131dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1425GB212boiler131dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1426GB212boiler131dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1427GB212boiler131dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1428GB212boiler131dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1429GB212boiler131dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1430GB212boiler131dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1431GB212boiler131dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1432GB212boiler131dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1433GB212boiler131dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1434GB212boiler131dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1435GB212boiler131dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1436GB212boiler131dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1437GB212boiler131dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1438GB212boiler131dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1439GB212boiler131dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1440GB212boiler131dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1441GB212boiler131dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1442GB212boiler131dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1443GB212boiler131dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1444GB212boiler131dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1445GB212boiler131dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1446GB212boiler131dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1447GB212boiler131dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1448GB212boiler131dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1449GB212boiler131dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1450GB212boiler131dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1451GB212boiler131dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1452GB212boiler131dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1453GB212boiler131dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1454GB212boiler131dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1455GB212boiler131dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10631
1456GB212boiler131dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10641
1457GB212boiler131dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591652
1458GB212boiler131dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591672
1459GB212boiler131nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1460GB212boiler131nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1461GB212boiler131nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1462GB212boiler131dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1463GC7000Fboiler132resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1464GC7000Fboiler132heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1465GC7000Fboiler132heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1466GC7000Fboiler132tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1467GC7000Fboiler132selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1468GC7000Fboiler132heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1469GC7000Fboiler132outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1470GC7000Fboiler132curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1471GC7000Fboiler132rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1472GC7000Fboiler132switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1473GC7000Fboiler132syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1474GC7000Fboiler132boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1475GC7000Fboiler132headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1476GC7000Fboiler132exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1477GC7000Fboiler132burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1478GC7000Fboiler132burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1479GC7000Fboiler132flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1480GC7000Fboiler132fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1481GC7000Fboiler132ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1482GC7000Fboiler132oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1483GC7000Fboiler132burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1484GC7000Fboiler132burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1485GC7000Fboiler132burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1486GC7000Fboiler132absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1487GC7000Fboiler132heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1488GC7000Fboiler132boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1489GC7000Fboiler132boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1490GC7000Fboiler132boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1491GC7000Fboiler132boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1492GC7000Fboiler132curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1493GC7000Fboiler132curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1494GC7000Fboiler132curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1495GC7000Fboiler132summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1496GC7000Fboiler132nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1497GC7000Fboiler132nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1498GC7000Fboiler132heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1499GC7000Fboiler132heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1500GC7000Fboiler132heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1501GC7000Fboiler132pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1502GC7000Fboiler132pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1503GC7000Fboiler132pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1504GC7000Fboiler132pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1505GC7000Fboiler132pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1506GC7000Fboiler132pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1507GC7000Fboiler132selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1508GC7000Fboiler132curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1509GC7000Fboiler132burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1510GC7000Fboiler132burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1511GC7000Fboiler132burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1512GC7000Fboiler132heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1513GC7000Fboiler132heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1514GC7000Fboiler132ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1515GC7000Fboiler132lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1516GC7000Fboiler132servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1517GC7000Fboiler132servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1518GC7000Fboiler132maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1519GC7000Fboiler132maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1520GC7000Fboiler132maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1521GC7000Fboiler132maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1522GC7000Fboiler132emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1523GC7000Fboiler132emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1524GC7000Fboiler132pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1525GC7000Fboiler132pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1526GC7000Fboiler132pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1527GC7000Fboiler132pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1528GC7000Fboiler132meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1529GC7000Fboiler132dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1530GC7000Fboiler132gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1531GC7000Fboiler132dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10692
1532GC7000Fboiler132nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1533GC7000Fboiler132dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10712
1534GC7000Fboiler132dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1535GC7000Fboiler132dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1536GC7000Fboiler132dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1537GC7000Fboiler132dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1538GC7000Fboiler132dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1539GC7000Fboiler132dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1540GC7000Fboiler132dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1541GC7000Fboiler132dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1542GC7000Fboiler132dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1543GC7000Fboiler132dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1544GC7000Fboiler132dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1545GC7000Fboiler132dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1546GC7000Fboiler132dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1547GC7000Fboiler132dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1548GC7000Fboiler132dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1549GC7000Fboiler132dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1550GC7000Fboiler132dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1551GC7000Fboiler132dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1552GC7000Fboiler132dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1553GC7000Fboiler132dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1554GC7000Fboiler132dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1555GC7000Fboiler132dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1556GC7000Fboiler132dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1557GC7000Fboiler132dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1558GC7000Fboiler132dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1559GC7000Fboiler132dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1560GC7000Fboiler132dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1561GC7000Fboiler132dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1562GC7000Fboiler132dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1563GC7000Fboiler132dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1564GC7000Fboiler132dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1565GC7000Fboiler132dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1566GC7000Fboiler132dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1567GC7000Fboiler132dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1568GC7000Fboiler132dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1569GC7000Fboiler132dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10631
1570GC7000Fboiler132dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10641
1571GC7000Fboiler132dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591652
1572GC7000Fboiler132dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591672
1573GC7000Fboiler132nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1574GC7000Fboiler132nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1575GC7000Fboiler132nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1576GC7000Fboiler132dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1577Logano GB125/KB195i, Logamatic MC110boiler133resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1578Logano GB125/KB195i, Logamatic MC110boiler133heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1579Logano GB125/KB195i, Logamatic MC110boiler133heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1580Logano GB125/KB195i, Logamatic MC110boiler133tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1581Logano GB125/KB195i, Logamatic MC110boiler133selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1582Logano GB125/KB195i, Logamatic MC110boiler133heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1583Logano GB125/KB195i, Logamatic MC110boiler133outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1584Logano GB125/KB195i, Logamatic MC110boiler133curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1585Logano GB125/KB195i, Logamatic MC110boiler133rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1586Logano GB125/KB195i, Logamatic MC110boiler133switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1587Logano GB125/KB195i, Logamatic MC110boiler133syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1588Logano GB125/KB195i, Logamatic MC110boiler133boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1589Logano GB125/KB195i, Logamatic MC110boiler133headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1590Logano GB125/KB195i, Logamatic MC110boiler133exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1591Logano GB125/KB195i, Logamatic MC110boiler133burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1592Logano GB125/KB195i, Logamatic MC110boiler133burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1593Logano GB125/KB195i, Logamatic MC110boiler133flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1594Logano GB125/KB195i, Logamatic MC110boiler133fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1595Logano GB125/KB195i, Logamatic MC110boiler133ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1596Logano GB125/KB195i, Logamatic MC110boiler133oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1597Logano GB125/KB195i, Logamatic MC110boiler133burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1598Logano GB125/KB195i, Logamatic MC110boiler133burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1599Logano GB125/KB195i, Logamatic MC110boiler133burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1600Logano GB125/KB195i, Logamatic MC110boiler133absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1601Logano GB125/KB195i, Logamatic MC110boiler133heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1602Logano GB125/KB195i, Logamatic MC110boiler133boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1603Logano GB125/KB195i, Logamatic MC110boiler133boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1604Logano GB125/KB195i, Logamatic MC110boiler133boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1605Logano GB125/KB195i, Logamatic MC110boiler133boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1606Logano GB125/KB195i, Logamatic MC110boiler133curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1607Logano GB125/KB195i, Logamatic MC110boiler133curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1608Logano GB125/KB195i, Logamatic MC110boiler133curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1609Logano GB125/KB195i, Logamatic MC110boiler133summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1610Logano GB125/KB195i, Logamatic MC110boiler133nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1611Logano GB125/KB195i, Logamatic MC110boiler133nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1612Logano GB125/KB195i, Logamatic MC110boiler133heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1613Logano GB125/KB195i, Logamatic MC110boiler133heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1614Logano GB125/KB195i, Logamatic MC110boiler133heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1615Logano GB125/KB195i, Logamatic MC110boiler133pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1616Logano GB125/KB195i, Logamatic MC110boiler133pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1617Logano GB125/KB195i, Logamatic MC110boiler133pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1618Logano GB125/KB195i, Logamatic MC110boiler133pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1619Logano GB125/KB195i, Logamatic MC110boiler133pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1620Logano GB125/KB195i, Logamatic MC110boiler133pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1621Logano GB125/KB195i, Logamatic MC110boiler133selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1622Logano GB125/KB195i, Logamatic MC110boiler133curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1623Logano GB125/KB195i, Logamatic MC110boiler133burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1624Logano GB125/KB195i, Logamatic MC110boiler133burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1625Logano GB125/KB195i, Logamatic MC110boiler133burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1626Logano GB125/KB195i, Logamatic MC110boiler133heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1627Logano GB125/KB195i, Logamatic MC110boiler133heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1628Logano GB125/KB195i, Logamatic MC110boiler133ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1629Logano GB125/KB195i, Logamatic MC110boiler133lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1630Logano GB125/KB195i, Logamatic MC110boiler133servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1631Logano GB125/KB195i, Logamatic MC110boiler133servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1632Logano GB125/KB195i, Logamatic MC110boiler133maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1633Logano GB125/KB195i, Logamatic MC110boiler133maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1634Logano GB125/KB195i, Logamatic MC110boiler133maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1635Logano GB125/KB195i, Logamatic MC110boiler133maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1636Logano GB125/KB195i, Logamatic MC110boiler133emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1637Logano GB125/KB195i, Logamatic MC110boiler133emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1638Logano GB125/KB195i, Logamatic MC110boiler133pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1639Logano GB125/KB195i, Logamatic MC110boiler133pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1640Logano GB125/KB195i, Logamatic MC110boiler133pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1641Logano GB125/KB195i, Logamatic MC110boiler133pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1642Logano GB125/KB195i, Logamatic MC110boiler133meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1643Logano GB125/KB195i, Logamatic MC110boiler133dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1644Logano GB125/KB195i, Logamatic MC110boiler133gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1645Logano GB125/KB195i, Logamatic MC110boiler133dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10692
1646Logano GB125/KB195i, Logamatic MC110boiler133nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1647Logano GB125/KB195i, Logamatic MC110boiler133dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10712
1648Logano GB125/KB195i, Logamatic MC110boiler133dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1649Logano GB125/KB195i, Logamatic MC110boiler133dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1650Logano GB125/KB195i, Logamatic MC110boiler133dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1651Logano GB125/KB195i, Logamatic MC110boiler133dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1652Logano GB125/KB195i, Logamatic MC110boiler133dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1653Logano GB125/KB195i, Logamatic MC110boiler133dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1654Logano GB125/KB195i, Logamatic MC110boiler133dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1655Logano GB125/KB195i, Logamatic MC110boiler133dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1656Logano GB125/KB195i, Logamatic MC110boiler133dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1657Logano GB125/KB195i, Logamatic MC110boiler133dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1658Logano GB125/KB195i, Logamatic MC110boiler133dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1659Logano GB125/KB195i, Logamatic MC110boiler133dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1660Logano GB125/KB195i, Logamatic MC110boiler133dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1661Logano GB125/KB195i, Logamatic MC110boiler133dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1662Logano GB125/KB195i, Logamatic MC110boiler133dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1663Logano GB125/KB195i, Logamatic MC110boiler133dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1664Logano GB125/KB195i, Logamatic MC110boiler133dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1665Logano GB125/KB195i, Logamatic MC110boiler133dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1666Logano GB125/KB195i, Logamatic MC110boiler133dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1667Logano GB125/KB195i, Logamatic MC110boiler133dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1668Logano GB125/KB195i, Logamatic MC110boiler133dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1669Logano GB125/KB195i, Logamatic MC110boiler133dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1670Logano GB125/KB195i, Logamatic MC110boiler133dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1671Logano GB125/KB195i, Logamatic MC110boiler133dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1672Logano GB125/KB195i, Logamatic MC110boiler133dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1673Logano GB125/KB195i, Logamatic MC110boiler133dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1674Logano GB125/KB195i, Logamatic MC110boiler133dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1675Logano GB125/KB195i, Logamatic MC110boiler133dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1676Logano GB125/KB195i, Logamatic MC110boiler133dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1677Logano GB125/KB195i, Logamatic MC110boiler133dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1678Logano GB125/KB195i, Logamatic MC110boiler133dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1679Logano GB125/KB195i, Logamatic MC110boiler133dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1680Logano GB125/KB195i, Logamatic MC110boiler133dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1681Logano GB125/KB195i, Logamatic MC110boiler133dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1682Logano GB125/KB195i, Logamatic MC110boiler133dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1683Logano GB125/KB195i, Logamatic MC110boiler133dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10631
1684Logano GB125/KB195i, Logamatic MC110boiler133dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10641
1685Logano GB125/KB195i, Logamatic MC110boiler133dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591652
1686Logano GB125/KB195i, Logamatic MC110boiler133dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591672
1687Logano GB125/KB195i, Logamatic MC110boiler133nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1688Logano GB125/KB195i, Logamatic MC110boiler133nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1689Logano GB125/KB195i, Logamatic MC110boiler133nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1690Logano GB125/KB195i, Logamatic MC110boiler133dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1691Greenstar 30Ri Compactboiler154resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1692Greenstar 30Ri Compactboiler154heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1693Greenstar 30Ri Compactboiler154heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1694Greenstar 30Ri Compactboiler154tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1695Greenstar 30Ri Compactboiler154selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1696Greenstar 30Ri Compactboiler154heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1697Greenstar 30Ri Compactboiler154outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1698Greenstar 30Ri Compactboiler154curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1699Greenstar 30Ri Compactboiler154rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1700Greenstar 30Ri Compactboiler154switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1701Greenstar 30Ri Compactboiler154syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1702Greenstar 30Ri Compactboiler154boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1703Greenstar 30Ri Compactboiler154headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1704Greenstar 30Ri Compactboiler154exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1705Greenstar 30Ri Compactboiler154burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1706Greenstar 30Ri Compactboiler154burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1707Greenstar 30Ri Compactboiler154flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1708Greenstar 30Ri Compactboiler154fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1709Greenstar 30Ri Compactboiler154ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1710Greenstar 30Ri Compactboiler154oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1711Greenstar 30Ri Compactboiler154burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1712Greenstar 30Ri Compactboiler154burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1713Greenstar 30Ri Compactboiler154burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1714Greenstar 30Ri Compactboiler154absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1715Greenstar 30Ri Compactboiler154heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1716Greenstar 30Ri Compactboiler154boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1717Greenstar 30Ri Compactboiler154boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1718Greenstar 30Ri Compactboiler154boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1719Greenstar 30Ri Compactboiler154boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1720Greenstar 30Ri Compactboiler154curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1721Greenstar 30Ri Compactboiler154curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1722Greenstar 30Ri Compactboiler154curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1723Greenstar 30Ri Compactboiler154summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1724Greenstar 30Ri Compactboiler154nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1725Greenstar 30Ri Compactboiler154nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1726Greenstar 30Ri Compactboiler154heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1727Greenstar 30Ri Compactboiler154heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1728Greenstar 30Ri Compactboiler154heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1729Greenstar 30Ri Compactboiler154pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1730Greenstar 30Ri Compactboiler154pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1731Greenstar 30Ri Compactboiler154pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1732Greenstar 30Ri Compactboiler154pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1733Greenstar 30Ri Compactboiler154pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1734Greenstar 30Ri Compactboiler154pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1735Greenstar 30Ri Compactboiler154selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1736Greenstar 30Ri Compactboiler154curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1737Greenstar 30Ri Compactboiler154burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1738Greenstar 30Ri Compactboiler154burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1739Greenstar 30Ri Compactboiler154burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1740Greenstar 30Ri Compactboiler154heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1741Greenstar 30Ri Compactboiler154heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1742Greenstar 30Ri Compactboiler154ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1743Greenstar 30Ri Compactboiler154lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1744Greenstar 30Ri Compactboiler154servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1745Greenstar 30Ri Compactboiler154servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1746Greenstar 30Ri Compactboiler154maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1747Greenstar 30Ri Compactboiler154maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1748Greenstar 30Ri Compactboiler154maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1749Greenstar 30Ri Compactboiler154maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1750Greenstar 30Ri Compactboiler154emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1751Greenstar 30Ri Compactboiler154emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1752Greenstar 30Ri Compactboiler154pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1753Greenstar 30Ri Compactboiler154pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1754Greenstar 30Ri Compactboiler154pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1755Greenstar 30Ri Compactboiler154pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1756Greenstar 30Ri Compactboiler154meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1757Greenstar 30Ri Compactboiler154dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1758Greenstar 30Ri Compactboiler154gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1759Greenstar 30Ri Compactboiler154dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10692
1760Greenstar 30Ri Compactboiler154nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1761Greenstar 30Ri Compactboiler154dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10712
1762Greenstar 30Ri Compactboiler154dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1763Greenstar 30Ri Compactboiler154dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1764Greenstar 30Ri Compactboiler154dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1765Greenstar 30Ri Compactboiler154dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1766Greenstar 30Ri Compactboiler154dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1767Greenstar 30Ri Compactboiler154dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1768Greenstar 30Ri Compactboiler154dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1769Greenstar 30Ri Compactboiler154dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1770Greenstar 30Ri Compactboiler154dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1771Greenstar 30Ri Compactboiler154dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1772Greenstar 30Ri Compactboiler154dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1773Greenstar 30Ri Compactboiler154dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1774Greenstar 30Ri Compactboiler154dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1775Greenstar 30Ri Compactboiler154dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1776Greenstar 30Ri Compactboiler154dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1777Greenstar 30Ri Compactboiler154dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1778Greenstar 30Ri Compactboiler154dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1779Greenstar 30Ri Compactboiler154dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1780Greenstar 30Ri Compactboiler154dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1781Greenstar 30Ri Compactboiler154dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1782Greenstar 30Ri Compactboiler154dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1783Greenstar 30Ri Compactboiler154dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1784Greenstar 30Ri Compactboiler154dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1785Greenstar 30Ri Compactboiler154dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1786Greenstar 30Ri Compactboiler154dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1787Greenstar 30Ri Compactboiler154dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1788Greenstar 30Ri Compactboiler154dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1789Greenstar 30Ri Compactboiler154dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1790Greenstar 30Ri Compactboiler154dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1791Greenstar 30Ri Compactboiler154dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1792Greenstar 30Ri Compactboiler154dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1793Greenstar 30Ri Compactboiler154dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1794Greenstar 30Ri Compactboiler154dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1795Greenstar 30Ri Compactboiler154dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1796Greenstar 30Ri Compactboiler154dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1797Greenstar 30Ri Compactboiler154dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10631
1798Greenstar 30Ri Compactboiler154dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10641
1799Greenstar 30Ri Compactboiler154dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591652
1800Greenstar 30Ri Compactboiler154dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591672
1801Greenstar 30Ri Compactboiler154nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1802Greenstar 30Ri Compactboiler154nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1803Greenstar 30Ri Compactboiler154nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1804Greenstar 30Ri Compactboiler154dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1805Suprapur-oboiler155resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1806Suprapur-oboiler155heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1807Suprapur-oboiler155heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1808Suprapur-oboiler155tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1809Suprapur-oboiler155selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1810Suprapur-oboiler155heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1811Suprapur-oboiler155outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1812Suprapur-oboiler155curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1813Suprapur-oboiler155rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1814Suprapur-oboiler155switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1815Suprapur-oboiler155syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1816Suprapur-oboiler155boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1817Suprapur-oboiler155headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1818Suprapur-oboiler155exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1819Suprapur-oboiler155burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1820Suprapur-oboiler155burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1821Suprapur-oboiler155flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1822Suprapur-oboiler155fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1823Suprapur-oboiler155ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1824Suprapur-oboiler155oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1825Suprapur-oboiler155burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1826Suprapur-oboiler155burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1827Suprapur-oboiler155burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1828Suprapur-oboiler155absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1829Suprapur-oboiler155heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1830Suprapur-oboiler155boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1831Suprapur-oboiler155boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1832Suprapur-oboiler155boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1833Suprapur-oboiler155boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1834Suprapur-oboiler155curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1835Suprapur-oboiler155curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1836Suprapur-oboiler155curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1837Suprapur-oboiler155summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1838Suprapur-oboiler155nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1839Suprapur-oboiler155nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1840Suprapur-oboiler155heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1841Suprapur-oboiler155heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1842Suprapur-oboiler155heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1843Suprapur-oboiler155pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1844Suprapur-oboiler155pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1845Suprapur-oboiler155pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1846Suprapur-oboiler155pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1847Suprapur-oboiler155pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1848Suprapur-oboiler155pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1849Suprapur-oboiler155selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1850Suprapur-oboiler155curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1851Suprapur-oboiler155burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1852Suprapur-oboiler155burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1853Suprapur-oboiler155burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1854Suprapur-oboiler155heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1855Suprapur-oboiler155heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1856Suprapur-oboiler155ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1857Suprapur-oboiler155lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1858Suprapur-oboiler155servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1859Suprapur-oboiler155servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1860Suprapur-oboiler155maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1861Suprapur-oboiler155maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1862Suprapur-oboiler155maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1863Suprapur-oboiler155maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1864Suprapur-oboiler155emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1865Suprapur-oboiler155emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1866Suprapur-oboiler155pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1867Suprapur-oboiler155pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1868Suprapur-oboiler155pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1869Suprapur-oboiler155pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1870Suprapur-oboiler155meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1871Suprapur-oboiler155dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1872Suprapur-oboiler155gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1873Suprapur-oboiler155dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10692
1874Suprapur-oboiler155nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1875Suprapur-oboiler155dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10712
1876Suprapur-oboiler155dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1877Suprapur-oboiler155dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1878Suprapur-oboiler155dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1879Suprapur-oboiler155dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1880Suprapur-oboiler155dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1881Suprapur-oboiler155dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1882Suprapur-oboiler155dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1883Suprapur-oboiler155dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1884Suprapur-oboiler155dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1885Suprapur-oboiler155dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1886Suprapur-oboiler155dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1887Suprapur-oboiler155dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1888Suprapur-oboiler155dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1889Suprapur-oboiler155dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1890Suprapur-oboiler155dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1891Suprapur-oboiler155dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1892Suprapur-oboiler155dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1893Suprapur-oboiler155dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1894Suprapur-oboiler155dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1895Suprapur-oboiler155dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1896Suprapur-oboiler155dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1897Suprapur-oboiler155dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1898Suprapur-oboiler155dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1899Suprapur-oboiler155dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1900Suprapur-oboiler155dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1901Suprapur-oboiler155dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1902Suprapur-oboiler155dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1903Suprapur-oboiler155dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1904Suprapur-oboiler155dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1905Suprapur-oboiler155dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1906Suprapur-oboiler155dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1907Suprapur-oboiler155dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1908Suprapur-oboiler155dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1909Suprapur-oboiler155dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1910Suprapur-oboiler155dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1911Suprapur-oboiler155dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10631
1912Suprapur-oboiler155dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10641
1913Suprapur-oboiler155dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591652
1914Suprapur-oboiler155dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591672
1915Suprapur-oboiler155nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1916Suprapur-oboiler155nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1917Suprapur-oboiler155nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1918Suprapur-oboiler155dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1919Cerapur Aeroboiler167resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1920Cerapur Aeroboiler167heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1921Cerapur Aeroboiler167heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1922Cerapur Aeroboiler167tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1923Cerapur Aeroboiler167selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1924Cerapur Aeroboiler167heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1925Cerapur Aeroboiler167outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1926Cerapur Aeroboiler167curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1927Cerapur Aeroboiler167rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1928Cerapur Aeroboiler167switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1929Cerapur Aeroboiler167syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1930Cerapur Aeroboiler167boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1931Cerapur Aeroboiler167headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1932Cerapur Aeroboiler167exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1933Cerapur Aeroboiler167burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1934Cerapur Aeroboiler167burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1935Cerapur Aeroboiler167flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1936Cerapur Aeroboiler167fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1937Cerapur Aeroboiler167ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1938Cerapur Aeroboiler167oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1939Cerapur Aeroboiler167burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1940Cerapur Aeroboiler167burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1941Cerapur Aeroboiler167burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1942Cerapur Aeroboiler167absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1943Cerapur Aeroboiler167heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1944Cerapur Aeroboiler167boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1945Cerapur Aeroboiler167boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1946Cerapur Aeroboiler167boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1947Cerapur Aeroboiler167boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1948Cerapur Aeroboiler167curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1949Cerapur Aeroboiler167curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1950Cerapur Aeroboiler167curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1951Cerapur Aeroboiler167summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1952Cerapur Aeroboiler167nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1953Cerapur Aeroboiler167nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1954Cerapur Aeroboiler167heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1955Cerapur Aeroboiler167heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1956Cerapur Aeroboiler167heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1957Cerapur Aeroboiler167pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1958Cerapur Aeroboiler167pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1959Cerapur Aeroboiler167pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1960Cerapur Aeroboiler167pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1961Cerapur Aeroboiler167pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1962Cerapur Aeroboiler167pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1963Cerapur Aeroboiler167selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1964Cerapur Aeroboiler167curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1965Cerapur Aeroboiler167burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1966Cerapur Aeroboiler167burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1967Cerapur Aeroboiler167burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1968Cerapur Aeroboiler167heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1969Cerapur Aeroboiler167heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1970Cerapur Aeroboiler167ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1971Cerapur Aeroboiler167lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1972Cerapur Aeroboiler167servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1973Cerapur Aeroboiler167servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1974Cerapur Aeroboiler167maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1975Cerapur Aeroboiler167maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1976Cerapur Aeroboiler167maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1977Cerapur Aeroboiler167maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1978Cerapur Aeroboiler167emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1979Cerapur Aeroboiler167emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1980Cerapur Aeroboiler167pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1981Cerapur Aeroboiler167pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1982Cerapur Aeroboiler167pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1983Cerapur Aeroboiler167pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1984Cerapur Aeroboiler167meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1985Cerapur Aeroboiler167dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1986Cerapur Aeroboiler167gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1987Cerapur Aeroboiler167dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10692
1988Cerapur Aeroboiler167nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1989Cerapur Aeroboiler167dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10712
1990Cerapur Aeroboiler167dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1991Cerapur Aeroboiler167dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1992Cerapur Aeroboiler167dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1993Cerapur Aeroboiler167dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1994Cerapur Aeroboiler167dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1995Cerapur Aeroboiler167dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1996Cerapur Aeroboiler167dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1997Cerapur Aeroboiler167dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1998Cerapur Aeroboiler167dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1999Cerapur Aeroboiler167dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
2000Cerapur Aeroboiler167dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
2001Cerapur Aeroboiler167dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
2002Cerapur Aeroboiler167dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
2003Cerapur Aeroboiler167dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
2004Cerapur Aeroboiler167dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
2005Cerapur Aeroboiler167dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
2006Cerapur Aeroboiler167dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
2007Cerapur Aeroboiler167dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
2008Cerapur Aeroboiler167dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
2009Cerapur Aeroboiler167dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
2010Cerapur Aeroboiler167dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
2011Cerapur Aeroboiler167dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
2012Cerapur Aeroboiler167dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
2013Cerapur Aeroboiler167dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
2014Cerapur Aeroboiler167dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
2015Cerapur Aeroboiler167dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
2016Cerapur Aeroboiler167dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
2017Cerapur Aeroboiler167dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
2018Cerapur Aeroboiler167dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
2019Cerapur Aeroboiler167dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
2020Cerapur Aeroboiler167dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
2021Cerapur Aeroboiler167dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
2022Cerapur Aeroboiler167dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
2023Cerapur Aeroboiler167dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
2024Cerapur Aeroboiler167dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
2025Cerapur Aeroboiler167dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10631
2026Cerapur Aeroboiler167dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10641
2027Cerapur Aeroboiler167dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591652
2028Cerapur Aeroboiler167dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591672
2029Cerapur Aeroboiler167nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
2030Cerapur Aeroboiler167nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
2031Cerapur Aeroboiler167nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
2032Cerapur Aeroboiler167dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
2033Hybrid Heatpumpboiler168resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
2034Hybrid Heatpumpboiler168heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
2035Hybrid Heatpumpboiler168heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
2036Hybrid Heatpumpboiler168tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
2037Hybrid Heatpumpboiler168selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
2038Hybrid Heatpumpboiler168heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
2039Hybrid Heatpumpboiler168outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
2040Hybrid Heatpumpboiler168curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
2041Hybrid Heatpumpboiler168rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
2042Hybrid Heatpumpboiler168switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
2043Hybrid Heatpumpboiler168syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
2044Hybrid Heatpumpboiler168boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
2045Hybrid Heatpumpboiler168headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
2046Hybrid Heatpumpboiler168exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
2047Hybrid Heatpumpboiler168burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
2048Hybrid Heatpumpboiler168burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
2049Hybrid Heatpumpboiler168flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
2050Hybrid Heatpumpboiler168fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
2051Hybrid Heatpumpboiler168ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
2052Hybrid Heatpumpboiler168oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
2053Hybrid Heatpumpboiler168burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
2054Hybrid Heatpumpboiler168burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
2055Hybrid Heatpumpboiler168burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
2056Hybrid Heatpumpboiler168absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
2057Hybrid Heatpumpboiler168heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
2058Hybrid Heatpumpboiler168boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
2059Hybrid Heatpumpboiler168boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
2060Hybrid Heatpumpboiler168boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
2061Hybrid Heatpumpboiler168boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
2062Hybrid Heatpumpboiler168curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
2063Hybrid Heatpumpboiler168curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
2064Hybrid Heatpumpboiler168curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
2065Hybrid Heatpumpboiler168summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
2066Hybrid Heatpumpboiler168nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
2067Hybrid Heatpumpboiler168nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
2068Hybrid Heatpumpboiler168heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
2069Hybrid Heatpumpboiler168heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
2070Hybrid Heatpumpboiler168heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
2071Hybrid Heatpumpboiler168pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
2072Hybrid Heatpumpboiler168pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
2073Hybrid Heatpumpboiler168pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
2074Hybrid Heatpumpboiler168pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
2075Hybrid Heatpumpboiler168pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
2076Hybrid Heatpumpboiler168pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
2077Hybrid Heatpumpboiler168selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
2078Hybrid Heatpumpboiler168curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
2079Hybrid Heatpumpboiler168burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
2080Hybrid Heatpumpboiler168burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
2081Hybrid Heatpumpboiler168burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
2082Hybrid Heatpumpboiler168heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
2083Hybrid Heatpumpboiler168heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
2084Hybrid Heatpumpboiler168ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
2085Hybrid Heatpumpboiler168lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
2086Hybrid Heatpumpboiler168servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
2087Hybrid Heatpumpboiler168servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
2088Hybrid Heatpumpboiler168maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
2089Hybrid Heatpumpboiler168maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
2090Hybrid Heatpumpboiler168maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
2091Hybrid Heatpumpboiler168maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
2092Hybrid Heatpumpboiler168emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
2093Hybrid Heatpumpboiler168emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
2094Hybrid Heatpumpboiler168pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
2095Hybrid Heatpumpboiler168pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
2096Hybrid Heatpumpboiler168pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
2097Hybrid Heatpumpboiler168pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
2098Hybrid Heatpumpboiler168meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
2099Hybrid Heatpumpboiler168dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
2100Hybrid Heatpumpboiler168gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
2101Hybrid Heatpumpboiler168dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10692
2102Hybrid Heatpumpboiler168nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
2103Hybrid Heatpumpboiler168dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10712
2104Hybrid Heatpumpboiler168dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
2105Hybrid Heatpumpboiler168dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
2106Hybrid Heatpumpboiler168dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
2107Hybrid Heatpumpboiler168dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
2108Hybrid Heatpumpboiler168dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
2109Hybrid Heatpumpboiler168dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
2110Hybrid Heatpumpboiler168dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
2111Hybrid Heatpumpboiler168dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
2112Hybrid Heatpumpboiler168dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
2113Hybrid Heatpumpboiler168dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
2114Hybrid Heatpumpboiler168dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
2115Hybrid Heatpumpboiler168dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
2116Hybrid Heatpumpboiler168dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
2117Hybrid Heatpumpboiler168dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
2118Hybrid Heatpumpboiler168dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
2119Hybrid Heatpumpboiler168dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
2120Hybrid Heatpumpboiler168dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
2121Hybrid Heatpumpboiler168dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
2122Hybrid Heatpumpboiler168dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
2123Hybrid Heatpumpboiler168dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
2124Hybrid Heatpumpboiler168dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
2125Hybrid Heatpumpboiler168dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
2126Hybrid Heatpumpboiler168dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
2127Hybrid Heatpumpboiler168dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
2128Hybrid Heatpumpboiler168dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
2129Hybrid Heatpumpboiler168dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
2130Hybrid Heatpumpboiler168dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
2131Hybrid Heatpumpboiler168dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
2132Hybrid Heatpumpboiler168dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
2133Hybrid Heatpumpboiler168dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
2134Hybrid Heatpumpboiler168dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
2135Hybrid Heatpumpboiler168dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
2136Hybrid Heatpumpboiler168dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
2137Hybrid Heatpumpboiler168dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
2138Hybrid Heatpumpboiler168dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
2139Hybrid Heatpumpboiler168dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10631
2140Hybrid Heatpumpboiler168dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10641
2141Hybrid Heatpumpboiler168dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591652
2142Hybrid Heatpumpboiler168dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591672
2143Hybrid Heatpumpboiler168nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
2144Hybrid Heatpumpboiler168nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
2145Hybrid Heatpumpboiler168nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
2146Hybrid Heatpumpboiler168dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
2147Logano GB212boiler170resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
2148Logano GB212boiler170heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
2149Logano GB212boiler170heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
2150Logano GB212boiler170tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
2151Logano GB212boiler170selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
2152Logano GB212boiler170heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
2153Logano GB212boiler170outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
2154Logano GB212boiler170curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
2155Logano GB212boiler170rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
2156Logano GB212boiler170switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
2157Logano GB212boiler170syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
2158Logano GB212boiler170boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
2159Logano GB212boiler170headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
2160Logano GB212boiler170exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
2161Logano GB212boiler170burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
2162Logano GB212boiler170burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
2163Logano GB212boiler170flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
2164Logano GB212boiler170fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
2165Logano GB212boiler170ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
2166Logano GB212boiler170oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
2167Logano GB212boiler170burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
2168Logano GB212boiler170burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
2169Logano GB212boiler170burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
2170Logano GB212boiler170absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
2171Logano GB212boiler170heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
2172Logano GB212boiler170boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
2173Logano GB212boiler170boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
2174Logano GB212boiler170boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
2175Logano GB212boiler170boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
2176Logano GB212boiler170curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
2177Logano GB212boiler170curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
2178Logano GB212boiler170curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
2179Logano GB212boiler170summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
2180Logano GB212boiler170nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
2181Logano GB212boiler170nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
2182Logano GB212boiler170heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
2183Logano GB212boiler170heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
2184Logano GB212boiler170heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
2185Logano GB212boiler170pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
2186Logano GB212boiler170pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
2187Logano GB212boiler170pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
2188Logano GB212boiler170pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
2189Logano GB212boiler170pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
2190Logano GB212boiler170pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
2191Logano GB212boiler170selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
2192Logano GB212boiler170curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
2193Logano GB212boiler170burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
2194Logano GB212boiler170burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
2195Logano GB212boiler170burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
2196Logano GB212boiler170heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
2197Logano GB212boiler170heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
2198Logano GB212boiler170ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
2199Logano GB212boiler170lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
2200Logano GB212boiler170servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
2201Logano GB212boiler170servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
2202Logano GB212boiler170maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
2203Logano GB212boiler170maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
2204Logano GB212boiler170maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
2205Logano GB212boiler170maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
2206Logano GB212boiler170emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
2207Logano GB212boiler170emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
2208Logano GB212boiler170pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
2209Logano GB212boiler170pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
2210Logano GB212boiler170pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
2211Logano GB212boiler170pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
2212Logano GB212boiler170meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
2213Logano GB212boiler170dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
2214Logano GB212boiler170gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
2215Logano GB212boiler170dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10692
2216Logano GB212boiler170nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
2217Logano GB212boiler170dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10712
2218Logano GB212boiler170dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
2219Logano GB212boiler170dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
2220Logano GB212boiler170dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
2221Logano GB212boiler170dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
2222Logano GB212boiler170dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
2223Logano GB212boiler170dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
2224Logano GB212boiler170dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
2225Logano GB212boiler170dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
2226Logano GB212boiler170dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
2227Logano GB212boiler170dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
2228Logano GB212boiler170dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
2229Logano GB212boiler170dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
2230Logano GB212boiler170dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
2231Logano GB212boiler170dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
2232Logano GB212boiler170dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
2233Logano GB212boiler170dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
2234Logano GB212boiler170dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
2235Logano GB212boiler170dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
2236Logano GB212boiler170dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
2237Logano GB212boiler170dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
2238Logano GB212boiler170dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
2239Logano GB212boiler170dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
2240Logano GB212boiler170dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
2241Logano GB212boiler170dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
2242Logano GB212boiler170dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
2243Logano GB212boiler170dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
2244Logano GB212boiler170dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
2245Logano GB212boiler170dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
2246Logano GB212boiler170dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
2247Logano GB212boiler170dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
2248Logano GB212boiler170dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
2249Logano GB212boiler170dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
2250Logano GB212boiler170dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
2251Logano GB212boiler170dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
2252Logano GB212boiler170dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
2253Logano GB212boiler170dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10631
2254Logano GB212boiler170dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10641
2255Logano GB212boiler170dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591652
2256Logano GB212boiler170dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591672
2257Logano GB212boiler170nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
2258Logano GB212boiler170nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
2259Logano GB212boiler170nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
2260Logano GB212boiler170dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
2261Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
2262Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
2263Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
2264Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
2265Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
2266Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
2267Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
2268Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
2269Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
2270Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
2271Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
2272Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
2273Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
2274Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
2275Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
2276Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
2277Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
2278Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
2279Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
2280Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
2281Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
2282Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
2283Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
2284Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
2285Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
2286Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
2287Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
2288Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
2289Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
2290Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
2291Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
2292Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
2293Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
2294Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
2295Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
2296Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
2297Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
2298Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
2299Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
2300Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
2301Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
2302Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
2303Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
2304Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
2305Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.nrgenergyuint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_energysensor.boiler_dhw_nrg591/10002
2306Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgheatenergy heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_heatingsensor.boiler_nrgheat501/100852
2307Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgcoolenergy coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_coolingsensor.boiler_nrgcool501/100872
2308Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172metertotalmeter totaluint24 (>=0<=167772)kWhfalsesensor.boiler_meter_totalsensor.boiler_metertotal501/100892
2309Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172metercompmeter compressoruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_compressorsensor.boiler_metercomp501/100912
2310Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172metereheatmeter e-heateruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_e-heatersensor.boiler_metereheat501/100932
2311Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172meterheatmeter heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/100952
2312Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172metercoolmeter coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_coolingsensor.boiler_metercool501/100972
2313Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.metermeteruint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/10022
2314Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172uptimetotalheatpump total uptimetime (>=0<=279620)minutesfalsesensor.boiler_heatpump_total_uptimesensor.boiler_uptimetotal501/60992
2315Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172uptimecontroltotal operating time heattime (>=0<=279620)minutesfalsesensor.boiler_total_operating_time_heatsensor.boiler_uptimecontrol501/601012
2316Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172uptimecompheatingoperating time compressor heatingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_heatingsensor.boiler_uptimecompheating501/601032
2317Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172uptimecompcoolingoperating time compressor coolingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_coolingsensor.boiler_uptimecompcooling501/601052
2318Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.uptimecompoperating time compressortime (>=0<=279620)minutesfalsesensor.boiler_dhw_operating_time_compressorsensor.boiler_dhw_uptimecomp591/6042
2319Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172uptimecomppooloperating time compressor pooltime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_poolsensor.boiler_uptimecomppool501/601072
2320Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172totalcompstartstotal compressor control startsuint24 (>=0<=16777214)falsesensor.boiler_total_compressor_control_startssensor.boiler_totalcompstarts5011092
2321Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatingstartsheating control startsuint24 (>=0<=16777214)falsesensor.boiler_heating_control_startssensor.boiler_heatingstarts5011112
2322Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172coolingstartscooling control startsuint24 (>=0<=16777214)falsesensor.boiler_cooling_control_startssensor.boiler_coolingstarts5011132
2323Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.startshpstarts hpuint24 (>=0<=16777214)falsesensor.boiler_dhw_starts_hpsensor.boiler_dhw_startshp59162
2324Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172poolstartspool control startsuint24 (>=0<=16777214)falsesensor.boiler_pool_control_startssensor.boiler_poolstarts5011152
2325Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgconstotaltotal energy consumptionuint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_consumptionsensor.boiler_nrgconstotal5011172
2326Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgconscomptotaltotal energy consumption compressoruint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_consumption_compressorsensor.boiler_nrgconscomptotal5011192
2327Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgconscompheatingenergy consumption compressor heatinguint24 (>=0<=16777214)kWhfalsesensor.boiler_energy_consumption_compressor_heatingsensor.boiler_nrgconscompheating5011212
2328Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.nrgconscompenergy consumption compressoruint24 (>=0<=16777214)kWhfalsesensor.boiler_dhw_energy_consumption_compressorsensor.boiler_dhw_nrgconscomp59182
2329Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgconscompcoolingenergy consumption compressor coolinguint24 (>=0<=16777214)kWhfalsesensor.boiler_energy_consumption_compressor_coolingsensor.boiler_nrgconscompcooling5011232
2330Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgconscomppoolenergy consumption compressor pooluint24 (>=0<=16777214)kWhfalsesensor.boiler_energy_consumption_compressor_poolsensor.boiler_nrgconscomppool5011252
2331Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxelecheatnrgconstotaltotal aux elec. heater energy consumptionuint24 (>=0<=16777214)kWhfalsesensor.boiler_total_aux_elec._heater_energy_consumptionsensor.boiler_auxelecheatnrgconstotal5011272
2332Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxelecheatnrgconsheatingaux elec. heater energy consumption heatinguint24 (>=0<=16777214)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_heatingsensor.boiler_auxelecheatnrgconsheating5011292
2333Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.auxelecheatnrgconsaux elec. heater energy consumptionuint24 (>=0<=16777214)kWhfalsesensor.boiler_dhw_aux_elec._heater_energy_consumptionsensor.boiler_dhw_auxelecheatnrgcons591102
2334Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxelecheatnrgconspoolaux elec. heater energy consumption pooluint24 (>=0<=16777214)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_poolsensor.boiler_auxelecheatnrgconspool5011312
2335Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgsupptotaltotal energy supplieduint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_suppliedsensor.boiler_nrgsupptotal5011332
2336Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgsuppheatingtotal energy supplied heatinguint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_supplied_heatingsensor.boiler_nrgsuppheating5011352
2337Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.nrgsupptotal energy warm supplieduint24 (>=0<=16777214)kWhfalsesensor.boiler_dhw_total_energy_warm_suppliedsensor.boiler_dhw_nrgsupp591122
2338Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgsuppcoolingtotal energy supplied coolinguint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_supplied_coolingsensor.boiler_nrgsuppcooling5011372
2339Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgsupppooltotal energy supplied pooluint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_supplied_poolsensor.boiler_nrgsupppool5011392
2340Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hppowercompressor power outputuint16 (>=0<=3199)kWfalsesensor.boiler_compressor_power_outputsensor.boiler_hppower501/101411
2341Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpmaxpowercompressor max poweruint8 (>=0<=100)%truenumber.boiler_compressor_max_powernumber.boiler_hpmaxpower5011421
2342Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pvmaxcomppv compressor max poweruint8 (>=0<=25)kWtruenumber.boiler_pv_compressor_max_powernumber.boiler_pvmaxcomp501/101431
2343Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172powerreductionpower reductionuint8 (>=30<=60)%truenumber.boiler_power_reductionnumber.boiler_powerreduction50101441
2344Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpsetdiffpressset differential pressureuint8 (>=150<=750)mbartruenumber.boiler_set_differential_pressurenumber.boiler_hpsetdiffpress50501451
2345Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpcomponhp compressorbooleanfalsebinary_sensor.boiler_hp_compressorbinary_sensor.boiler_hpcompon5011461
2346Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpactivitycompressor activityenum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm]falsesensor.boiler_compressor_activitysensor.boiler_hpactivity5011471
2347Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpbrinepumpspdbrine pump speeduint8 (>=0<=100)%falsesensor.boiler_brine_pump_speedsensor.boiler_hpbrinepumpspd5011481
2348Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpswitchvalveswitch valvebooleanfalsebinary_sensor.boiler_switch_valvebinary_sensor.boiler_hpswitchvalve5011491
2349Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpcompspdcompressor speeduint8 (>=0<=100)%falsesensor.boiler_compressor_speedsensor.boiler_hpcompspd5011501
2350Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpcircspdcirculation pump speeduint8 (>=0<=100)%falsesensor.boiler_circulation_pump_speedsensor.boiler_hpcircspd5011511
2351Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpbrineinbrine in/evaporatorint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_in/evaporatorsensor.boiler_hpbrinein501/101521
2352Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpbrineoutbrine out/condenserint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_out/condensersensor.boiler_hpbrineout501/101531
2353Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptc0heat carrier return (TC0)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_return_(TC0)sensor.boiler_hptc0501/101541
2354Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptc1heat carrier forward (TC1)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_forward_(TC1)sensor.boiler_hptc1501/101551
2355Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptc3condenser temperature (TC3)int16 (>=-3199<=3199)Cfalsesensor.boiler_condenser_temperature_(TC3)sensor.boiler_hptc3501/101561
2356Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptr1compressor temperature (TR1)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_temperature_(TR1)sensor.boiler_hptr1501/101571
2357Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptr3refrigerant temperature liquid side (condenser output) (TR3)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3)sensor.boiler_hptr3501/101581
2358Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptr4evaporator inlet temperature (TR4)int16 (>=-3199<=3199)Cfalsesensor.boiler_evaporator_inlet_temperature_(TR4)sensor.boiler_hptr4501/101591
2359Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptr5compressor inlet temperature (TR5)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_inlet_temperature_(TR5)sensor.boiler_hptr5501/101601
2360Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptr6compressor outlet temperature (TR6)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_outlet_temperature_(TR6)sensor.boiler_hptr6501/101611
2361Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptr7refrigerant temperature gas side (condenser input) (TR7)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7)sensor.boiler_hptr7501/101621
2362Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptl2air inlet temperature (TL2)int16 (>=-3199<=3199)Cfalsesensor.boiler_air_inlet_temperature_(TL2)sensor.boiler_hptl2501/101631
2363Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hppl1low pressure side temperature (PL1)int16 (>=-3199<=3199)Cfalsesensor.boiler_low_pressure_side_temperature_(PL1)sensor.boiler_hppl1501/101641
2364Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpph1high pressure side temperature (PH1)int16 (>=-3199<=3199)Cfalsesensor.boiler_high_pressure_side_temperature_(PH1)sensor.boiler_hpph1501/101651
2365Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpta4drain pan temp (TA4)int16 (>=-3199<=3199)Cfalsesensor.boiler_drain_pan_temp_(TA4)sensor.boiler_hpta4501/101661
2366Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptw1reservoir temp (TW1)int16 (>=-3199<=3199)Cfalsesensor.boiler_reservoir_temp_(TW1)sensor.boiler_hptw1501/101671
2367Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172poolsettemppool set temperatureuint8 (>=0<=127)Ctruenumber.boiler_pool_set_temperaturenumber.boiler_poolsettemp501/21681
2368Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hp4way4-way valve (VR4)enum [cooling & defrost\|heating & dhw]falsesensor.boiler_4-way_valve_(VR4)sensor.boiler_hp4way5011691
2369Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpin1input 1 statebooleanfalsebinary_sensor.boiler_input_1_statebinary_sensor.boiler_hpin15011701
2370Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpin1optinput 1 optionsstringtruesensor.boiler_input_1_optionssensor.boiler_hpin1opt5011718
2371Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpin2input 2 statebooleanfalsebinary_sensor.boiler_input_2_statebinary_sensor.boiler_hpin25011791
2372Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpin2optinput 2 optionsstringtruesensor.boiler_input_2_optionssensor.boiler_hpin2opt5011808
2373Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpin3input 3 statebooleanfalsebinary_sensor.boiler_input_3_statebinary_sensor.boiler_hpin35011881
2374Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpin3optinput 3 optionsstringtruesensor.boiler_input_3_optionssensor.boiler_hpin3opt5011898
2375Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpin4input 4 statebooleanfalsebinary_sensor.boiler_input_4_statebinary_sensor.boiler_hpin45011971
2376Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpin4optinput 4 optionsstringtruesensor.boiler_input_4_optionssensor.boiler_hpin4opt5011988
2377Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172maxheatcompheat limit compressorenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_compressorselect.boiler_maxheatcomp5012061
2378Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172maxheatheatheat limit heatingenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_heatingselect.boiler_maxheatheat5012071
2379Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.maxheatheat limitenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_dhw_heat_limitselect.boiler_dhw_maxheat591141
2380Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172mandefrostmanual defrostbooleantrueswitch.boiler_manual_defrostswitch.boiler_mandefrost5012081
2381Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pvcoolingcooling only with PVbooleantrueswitch.boiler_cooling_only_with_PVswitch.boiler_pvcooling5012091
2382Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxheateronlyaux heater onlybooleantrueswitch.boiler_aux_heater_onlyswitch.boiler_auxheateronly5012101
2383Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxheateroffdisable aux heaterbooleantrueswitch.boiler_disable_aux_heaterswitch.boiler_auxheateroff5012111
2384Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxheaterstatusaux heater statusenum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm]falsesensor.boiler_aux_heater_statussensor.boiler_auxheaterstatus5012121
2385Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxheaterlevelaux heater leveluint8 (>=0<=100)%falsesensor.boiler_aux_heater_levelsensor.boiler_auxheaterlevel5012131
2386Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxheaterdelayaux heater on delayuint16 (>=10<=1000)K*mintruenumber.boiler_aux_heater_on_delaynumber.boiler_auxheaterdelay50102141
2387Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxmaxlimitaux heater max limituint8 (>=0<=10)Ktruenumber.boiler_aux_heater_max_limitnumber.boiler_auxmaxlimit501/102151
2388Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxlimitstartaux heater limit startuint8 (>=0<=10)Ktruenumber.boiler_aux_heater_limit_startnumber.boiler_auxlimitstart501/102161
2389Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxheatrmodeaux heater modeenum [eco\|comfort]trueselect.boiler_aux_heater_modeselect.boiler_auxheatrmode5012171
2390Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hphystheaton/off hyst heatuint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_heatnumber.boiler_hphystheat5052181
2391Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hphystcoolon/off hyst cooluint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_coolnumber.boiler_hphystcool5052191
2392Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hphystpoolon/off hyst pooluint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_poolnumber.boiler_hphystpool5052201
2393Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172silentmodesilent modeenum [off\|auto\|on]trueselect.boiler_silent_modeselect.boiler_silentmode5012211
2394Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172silentfromsilent mode fromuint8 (>=0<=3810)minutestruenumber.boiler_silent_mode_fromnumber.boiler_silentfrom50152221
2395Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172silenttosilent mode touint8 (>=0<=3810)minutestruenumber.boiler_silent_mode_tonumber.boiler_silentto50152231
2396Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172mintempsilentmin outside temp for silent modeint8 (>=-126<=126)Ctruenumber.boiler_min_outside_temp_for_silent_modenumber.boiler_mintempsilent5012241
2397Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172tempparmodeoutside temp parallel modeint8 (>=-126<=126)Ctruenumber.boiler_outside_temp_parallel_modenumber.boiler_tempparmode5012251
2398Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxheatmixaux heater mixing valveint8 (>=-100<=100)%falsesensor.boiler_aux_heater_mixing_valvesensor.boiler_auxheatmix5012261
2399Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172tempdiffheattemp diff TC3/TC0 heatuint8 (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_heatnumber.boiler_tempdiffheat501/102271
2400Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172tempdiffcooltemp diff TC3/TC0 cooluint8 (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_coolnumber.boiler_tempdiffcool501/102281
2401Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172vpcoolingvalve/pump coolingbooleantrueswitch.boiler_valve/pump_coolingswitch.boiler_vpcooling5012291
2402Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatcableheating cablebooleantrueswitch.boiler_heating_cableswitch.boiler_heatcable5012301
2403Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172vc0valveVC0 valvebooleantrueswitch.boiler_VC0_valveswitch.boiler_vc0valve5012311
2404Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172primepumpprimary heatpumpbooleantrueswitch.boiler_primary_heatpumpswitch.boiler_primepump5012321
2405Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172primepumpmodprimary heatpump modulationuint8 (>=0<=100)%truenumber.boiler_primary_heatpump_modulationnumber.boiler_primepumpmod5012331
2406Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hp3way3-way valvebooleantrueswitch.boiler_3-way_valveswitch.boiler_hp3way5012341
2407Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172elheatstep1el. heater step 1booleantrueswitch.boiler_el._heater_step_1switch.boiler_elheatstep15012351
2408Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172elheatstep2el. heater step 2booleantrueswitch.boiler_el._heater_step_2switch.boiler_elheatstep25012361
2409Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172elheatstep3el. heater step 3booleantrueswitch.boiler_el._heater_step_3switch.boiler_elheatstep35012371
2410Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpea0condensate reservoir heating (EA0)booleanfalsebinary_sensor.boiler_condensate_reservoir_heating_(EA0)binary_sensor.boiler_hpea05012381
2411Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hppumpmodeprimary heatpump modeenum [auto\|continuous]trueselect.boiler_primary_heatpump_modeselect.boiler_hppumpmode5012391
2412Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172fanfanuint8 (>=20<=100)%truenumber.boiler_fannumber.boiler_fan5012401
2413Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172shutdownshutdowncmd [off\|on]truesensor.boiler_shutdownsensor.boiler_shutdown5012411
2414Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpcurrpowercompressor current poweruint16 (>=0<=31999)Wfalsesensor.boiler_compressor_current_powersensor.boiler_hpcurrpower5012421
2415Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hppowerlimitpower limituint16 (>=0<=31999)Wtruenumber.boiler_power_limitnumber.boiler_hppowerlimit5012431
2416Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.alternatingopalternating operationbooleantrueswitch.boiler_dhw_alternating_operationswitch.boiler_dhw_alternatingop591151
2417Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.altopprioheatprioritise heating during dhwuint8 (>=20<=120)minutestruenumber.boiler_dhw_prioritise_heating_during_dhwnumber.boiler_dhw_altopprioheat591161
2418Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.altopprioprioritise dhw during heatinguint8 (>=30<=120)minutestruenumber.boiler_dhw_prioritise_dhw_during_heatingnumber.boiler_dhw_altopprio591171
2419Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.comfoffcomfort switch offuint8 (>=15<=65)Ctruenumber.boiler_dhw_comfort_switch_offnumber.boiler_dhw_comfoff591181
2420Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.ecooffeco switch offuint8 (>=15<=65)Ctruenumber.boiler_dhw_eco_switch_offnumber.boiler_dhw_ecooff591191
2421Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.ecoplusoffeco+ switch offuint8 (>=48<=63)Ctruenumber.boiler_dhw_eco+_switch_offnumber.boiler_dhw_ecoplusoff591201
2422Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.comfdiffcomfort diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_comfort_diffnumber.boiler_dhw_comfdiff591211
2423Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.ecodiffeco diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_eco_diffnumber.boiler_dhw_ecodiff591221
2424Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.ecoplusdiffeco+ diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_eco+_diffnumber.boiler_dhw_ecoplusdiff591231
2425Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.comfstopcomfort stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_comfort_stop_tempnumber.boiler_dhw_comfstop591241
2426Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.ecostopeco stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_eco_stop_tempnumber.boiler_dhw_ecostop591251
2427Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.ecoplusstopeco+ stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_eco+_stop_tempnumber.boiler_dhw_ecoplusstop591261
2428Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.hpcircpumpcirculation pump available during dhwbooleantrueswitch.boiler_dhw_circulation_pump_available_during_dhwswitch.boiler_dhw_hpcircpump591271
2429Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
2430Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
2431Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
2432Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
2433Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
2434Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
2435Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
2436Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
2437Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
2438Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
2439Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
2440Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
2441Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
2442Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
2443Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
2444Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
2445Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
2446Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
2447Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
2448Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
2449Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
2450Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
2451Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
2452Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
2453Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
2454Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
2455Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
2456Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
2457Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
2458Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
2459Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
2460Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
2461Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
2462Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
2463Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
2464Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10631
2465Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10641
2466Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591652
2467Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591672
2468Geo 5xxboiler173resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
2469Geo 5xxboiler173heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
2470Geo 5xxboiler173heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
2471Geo 5xxboiler173tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
2472Geo 5xxboiler173selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
2473Geo 5xxboiler173heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
2474Geo 5xxboiler173outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
2475Geo 5xxboiler173curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
2476Geo 5xxboiler173rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
2477Geo 5xxboiler173switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
2478Geo 5xxboiler173syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
2479Geo 5xxboiler173boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
2480Geo 5xxboiler173headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
2481Geo 5xxboiler173heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
2482Geo 5xxboiler173heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
2483Geo 5xxboiler173heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
2484Geo 5xxboiler173pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
2485Geo 5xxboiler173pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
2486Geo 5xxboiler173pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
2487Geo 5xxboiler173pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
2488Geo 5xxboiler173pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
2489Geo 5xxboiler173pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
2490Geo 5xxboiler173selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
2491Geo 5xxboiler173curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
2492Geo 5xxboiler173burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
2493Geo 5xxboiler173burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
2494Geo 5xxboiler173burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
2495Geo 5xxboiler173heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
2496Geo 5xxboiler173heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
2497Geo 5xxboiler173ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
2498Geo 5xxboiler173lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
2499Geo 5xxboiler173servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
2500Geo 5xxboiler173servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661