Files
EMS-ESP32/docs/dump_entities.csv
2025-05-16 09:22:58 +02:00

921 KiB

1device namedevice typeproduct idshortnamefullnametype [options...] \| (min/max)uomwriteablediscovery entityid v3.4discovery entityidmodbus unit identifiermodbus blockmodbus scale factormodbus offsetmodbus count
2CS5800i, CS6800i, WLW176i, WLW186iboiler8resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
3CS5800i, CS6800i, WLW176i, WLW186iboiler8heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
4CS5800i, CS6800i, WLW176i, WLW186iboiler8heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
5CS5800i, CS6800i, WLW176i, WLW186iboiler8tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
6CS5800i, CS6800i, WLW176i, WLW186iboiler8selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
7CS5800i, CS6800i, WLW176i, WLW186iboiler8heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
8CS5800i, CS6800i, WLW176i, WLW186iboiler8outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
9CS5800i, CS6800i, WLW176i, WLW186iboiler8curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
10CS5800i, CS6800i, WLW176i, WLW186iboiler8rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
11CS5800i, CS6800i, WLW176i, WLW186iboiler8switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
12CS5800i, CS6800i, WLW176i, WLW186iboiler8syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
13CS5800i, CS6800i, WLW176i, WLW186iboiler8boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
14CS5800i, CS6800i, WLW176i, WLW186iboiler8headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
15CS5800i, CS6800i, WLW176i, WLW186iboiler8heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
16CS5800i, CS6800i, WLW176i, WLW186iboiler8heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
17CS5800i, CS6800i, WLW176i, WLW186iboiler8heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
18CS5800i, CS6800i, WLW176i, WLW186iboiler8pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
19CS5800i, CS6800i, WLW176i, WLW186iboiler8pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
20CS5800i, CS6800i, WLW176i, WLW186iboiler8pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
21CS5800i, CS6800i, WLW176i, WLW186iboiler8pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
22CS5800i, CS6800i, WLW176i, WLW186iboiler8pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
23CS5800i, CS6800i, WLW176i, WLW186iboiler8pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
24CS5800i, CS6800i, WLW176i, WLW186iboiler8selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
25CS5800i, CS6800i, WLW176i, WLW186iboiler8curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
26CS5800i, CS6800i, WLW176i, WLW186iboiler8burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
27CS5800i, CS6800i, WLW176i, WLW186iboiler8burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
28CS5800i, CS6800i, WLW176i, WLW186iboiler8burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
29CS5800i, CS6800i, WLW176i, WLW186iboiler8heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
30CS5800i, CS6800i, WLW176i, WLW186iboiler8heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
31CS5800i, CS6800i, WLW176i, WLW186iboiler8ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
32CS5800i, CS6800i, WLW176i, WLW186iboiler8lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
33CS5800i, CS6800i, WLW176i, WLW186iboiler8servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
34CS5800i, CS6800i, WLW176i, WLW186iboiler8servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
35CS5800i, CS6800i, WLW176i, WLW186iboiler8maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
36CS5800i, CS6800i, WLW176i, WLW186iboiler8maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
37CS5800i, CS6800i, WLW176i, WLW186iboiler8maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
38CS5800i, CS6800i, WLW176i, WLW186iboiler8maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
39CS5800i, CS6800i, WLW176i, WLW186iboiler8emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
40CS5800i, CS6800i, WLW176i, WLW186iboiler8emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
41CS5800i, CS6800i, WLW176i, WLW186iboiler8pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
42CS5800i, CS6800i, WLW176i, WLW186iboiler8pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
43CS5800i, CS6800i, WLW176i, WLW186iboiler8pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
44CS5800i, CS6800i, WLW176i, WLW186iboiler8pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
45CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
46CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.nrgenergyuint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_energysensor.boiler_dhw_nrg591/10002
47CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgheatenergy heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_heatingsensor.boiler_nrgheat501/100852
48CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgcoolenergy coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_coolingsensor.boiler_nrgcool501/100872
49CS5800i, CS6800i, WLW176i, WLW186iboiler8metertotalmeter totaluint24 (>=0<=167772)kWhfalsesensor.boiler_meter_totalsensor.boiler_metertotal501/100892
50CS5800i, CS6800i, WLW176i, WLW186iboiler8metercompmeter compressoruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_compressorsensor.boiler_metercomp501/100912
51CS5800i, CS6800i, WLW176i, WLW186iboiler8metereheatmeter e-heateruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_e-heatersensor.boiler_metereheat501/100932
52CS5800i, CS6800i, WLW176i, WLW186iboiler8meterheatmeter heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/100952
53CS5800i, CS6800i, WLW176i, WLW186iboiler8metercoolmeter coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_coolingsensor.boiler_metercool501/100972
54CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.metermeteruint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/10022
55CS5800i, CS6800i, WLW176i, WLW186iboiler8uptimetotalheatpump total uptimetime (>=0<=279620)minutesfalsesensor.boiler_heatpump_total_uptimesensor.boiler_uptimetotal501/60992
56CS5800i, CS6800i, WLW176i, WLW186iboiler8uptimecontroltotal operating time heattime (>=0<=279620)minutesfalsesensor.boiler_total_operating_time_heatsensor.boiler_uptimecontrol501/601012
57CS5800i, CS6800i, WLW176i, WLW186iboiler8uptimecompheatingoperating time compressor heatingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_heatingsensor.boiler_uptimecompheating501/601032
58CS5800i, CS6800i, WLW176i, WLW186iboiler8uptimecompcoolingoperating time compressor coolingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_coolingsensor.boiler_uptimecompcooling501/601052
59CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.uptimecompoperating time compressortime (>=0<=279620)minutesfalsesensor.boiler_dhw_operating_time_compressorsensor.boiler_dhw_uptimecomp591/6042
60CS5800i, CS6800i, WLW176i, WLW186iboiler8uptimecomppooloperating time compressor pooltime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_poolsensor.boiler_uptimecomppool501/601072
61CS5800i, CS6800i, WLW176i, WLW186iboiler8totalcompstartstotal compressor control startsuint24 (>=0<=16777214)falsesensor.boiler_total_compressor_control_startssensor.boiler_totalcompstarts5011092
62CS5800i, CS6800i, WLW176i, WLW186iboiler8heatingstartsheating control startsuint24 (>=0<=16777214)falsesensor.boiler_heating_control_startssensor.boiler_heatingstarts5011112
63CS5800i, CS6800i, WLW176i, WLW186iboiler8coolingstartscooling control startsuint24 (>=0<=16777214)falsesensor.boiler_cooling_control_startssensor.boiler_coolingstarts5011132
64CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.startshpstarts hpuint24 (>=0<=16777214)falsesensor.boiler_dhw_starts_hpsensor.boiler_dhw_startshp59162
65CS5800i, CS6800i, WLW176i, WLW186iboiler8poolstartspool control startsuint24 (>=0<=16777214)falsesensor.boiler_pool_control_startssensor.boiler_poolstarts5011152
66CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgconstotaltotal energy consumptionuint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_consumptionsensor.boiler_nrgconstotal5011172
67CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgconscomptotaltotal energy consumption compressoruint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_consumption_compressorsensor.boiler_nrgconscomptotal5011192
68CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgconscompheatingenergy consumption compressor heatinguint24 (>=0<=16777214)kWhfalsesensor.boiler_energy_consumption_compressor_heatingsensor.boiler_nrgconscompheating5011212
69CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.nrgconscompenergy consumption compressoruint24 (>=0<=16777214)kWhfalsesensor.boiler_dhw_energy_consumption_compressorsensor.boiler_dhw_nrgconscomp59182
70CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgconscompcoolingenergy consumption compressor coolinguint24 (>=0<=16777214)kWhfalsesensor.boiler_energy_consumption_compressor_coolingsensor.boiler_nrgconscompcooling5011232
71CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgconscomppoolenergy consumption compressor pooluint24 (>=0<=16777214)kWhfalsesensor.boiler_energy_consumption_compressor_poolsensor.boiler_nrgconscomppool5011252
72CS5800i, CS6800i, WLW176i, WLW186iboiler8auxelecheatnrgconstotaltotal aux elec. heater energy consumptionuint24 (>=0<=16777214)kWhfalsesensor.boiler_total_aux_elec._heater_energy_consumptionsensor.boiler_auxelecheatnrgconstotal5011272
73CS5800i, CS6800i, WLW176i, WLW186iboiler8auxelecheatnrgconsheatingaux elec. heater energy consumption heatinguint24 (>=0<=16777214)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_heatingsensor.boiler_auxelecheatnrgconsheating5011292
74CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.auxelecheatnrgconsaux elec. heater energy consumptionuint24 (>=0<=16777214)kWhfalsesensor.boiler_dhw_aux_elec._heater_energy_consumptionsensor.boiler_dhw_auxelecheatnrgcons591102
75CS5800i, CS6800i, WLW176i, WLW186iboiler8auxelecheatnrgconspoolaux elec. heater energy consumption pooluint24 (>=0<=16777214)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_poolsensor.boiler_auxelecheatnrgconspool5011312
76CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgsupptotaltotal energy supplieduint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_suppliedsensor.boiler_nrgsupptotal5011332
77CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgsuppheatingtotal energy supplied heatinguint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_supplied_heatingsensor.boiler_nrgsuppheating5011352
78CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.nrgsupptotal energy warm supplieduint24 (>=0<=16777214)kWhfalsesensor.boiler_dhw_total_energy_warm_suppliedsensor.boiler_dhw_nrgsupp591122
79CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgsuppcoolingtotal energy supplied coolinguint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_supplied_coolingsensor.boiler_nrgsuppcooling5011372
80CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgsupppooltotal energy supplied pooluint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_supplied_poolsensor.boiler_nrgsupppool5011392
81CS5800i, CS6800i, WLW176i, WLW186iboiler8hppowercompressor power outputuint16 (>=0<=3199)kWfalsesensor.boiler_compressor_power_outputsensor.boiler_hppower501/101411
82CS5800i, CS6800i, WLW176i, WLW186iboiler8hpmaxpowercompressor max poweruint8 (>=0<=100)%truenumber.boiler_compressor_max_powernumber.boiler_hpmaxpower5011421
83CS5800i, CS6800i, WLW176i, WLW186iboiler8pvmaxcomppv compressor max poweruint8 (>=0<=25)kWtruenumber.boiler_pv_compressor_max_powernumber.boiler_pvmaxcomp501/101431
84CS5800i, CS6800i, WLW176i, WLW186iboiler8powerreductionpower reductionuint8 (>=30<=60)%truenumber.boiler_power_reductionnumber.boiler_powerreduction50101441
85CS5800i, CS6800i, WLW176i, WLW186iboiler8hpsetdiffpressset differential pressureuint8 (>=150<=750)mbartruenumber.boiler_set_differential_pressurenumber.boiler_hpsetdiffpress50501451
86CS5800i, CS6800i, WLW176i, WLW186iboiler8hpcomponhp compressorbooleanfalsebinary_sensor.boiler_hp_compressorbinary_sensor.boiler_hpcompon5011461
87CS5800i, CS6800i, WLW176i, WLW186iboiler8hpactivitycompressor activityenum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm]falsesensor.boiler_compressor_activitysensor.boiler_hpactivity5011471
88CS5800i, CS6800i, WLW176i, WLW186iboiler8hpbrinepumpspdbrine pump speeduint8 (>=0<=100)%falsesensor.boiler_brine_pump_speedsensor.boiler_hpbrinepumpspd5011481
89CS5800i, CS6800i, WLW176i, WLW186iboiler8hpswitchvalveswitch valvebooleanfalsebinary_sensor.boiler_switch_valvebinary_sensor.boiler_hpswitchvalve5011491
90CS5800i, CS6800i, WLW176i, WLW186iboiler8hpcompspdcompressor speeduint8 (>=0<=100)%falsesensor.boiler_compressor_speedsensor.boiler_hpcompspd5011501
91CS5800i, CS6800i, WLW176i, WLW186iboiler8hpcircspdcirculation pump speeduint8 (>=0<=100)%falsesensor.boiler_circulation_pump_speedsensor.boiler_hpcircspd5011511
92CS5800i, CS6800i, WLW176i, WLW186iboiler8hpbrineinbrine in/evaporatorint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_in/evaporatorsensor.boiler_hpbrinein501/101521
93CS5800i, CS6800i, WLW176i, WLW186iboiler8hpbrineoutbrine out/condenserint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_out/condensersensor.boiler_hpbrineout501/101531
94CS5800i, CS6800i, WLW176i, WLW186iboiler8hptc0heat carrier return (TC0)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_return_(TC0)sensor.boiler_hptc0501/101541
95CS5800i, CS6800i, WLW176i, WLW186iboiler8hptc1heat carrier forward (TC1)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_forward_(TC1)sensor.boiler_hptc1501/101551
96CS5800i, CS6800i, WLW176i, WLW186iboiler8hptc3condenser temperature (TC3)int16 (>=-3199<=3199)Cfalsesensor.boiler_condenser_temperature_(TC3)sensor.boiler_hptc3501/101561
97CS5800i, CS6800i, WLW176i, WLW186iboiler8hptr1compressor temperature (TR1)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_temperature_(TR1)sensor.boiler_hptr1501/101571
98CS5800i, CS6800i, WLW176i, WLW186iboiler8hptr3refrigerant temperature liquid side (condenser output) (TR3)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3)sensor.boiler_hptr3501/101581
99CS5800i, CS6800i, WLW176i, WLW186iboiler8hptr4evaporator inlet temperature (TR4)int16 (>=-3199<=3199)Cfalsesensor.boiler_evaporator_inlet_temperature_(TR4)sensor.boiler_hptr4501/101591
100CS5800i, CS6800i, WLW176i, WLW186iboiler8hptr5compressor inlet temperature (TR5)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_inlet_temperature_(TR5)sensor.boiler_hptr5501/101601
101CS5800i, CS6800i, WLW176i, WLW186iboiler8hptr6compressor outlet temperature (TR6)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_outlet_temperature_(TR6)sensor.boiler_hptr6501/101611
102CS5800i, CS6800i, WLW176i, WLW186iboiler8hptr7refrigerant temperature gas side (condenser input) (TR7)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7)sensor.boiler_hptr7501/101621
103CS5800i, CS6800i, WLW176i, WLW186iboiler8hptl2air inlet temperature (TL2)int16 (>=-3199<=3199)Cfalsesensor.boiler_air_inlet_temperature_(TL2)sensor.boiler_hptl2501/101631
104CS5800i, CS6800i, WLW176i, WLW186iboiler8hppl1low pressure side temperature (PL1)int16 (>=-3199<=3199)Cfalsesensor.boiler_low_pressure_side_temperature_(PL1)sensor.boiler_hppl1501/101641
105CS5800i, CS6800i, WLW176i, WLW186iboiler8hpph1high pressure side temperature (PH1)int16 (>=-3199<=3199)Cfalsesensor.boiler_high_pressure_side_temperature_(PH1)sensor.boiler_hpph1501/101651
106CS5800i, CS6800i, WLW176i, WLW186iboiler8hpta4drain pan temp (TA4)int16 (>=-3199<=3199)Cfalsesensor.boiler_drain_pan_temp_(TA4)sensor.boiler_hpta4501/101661
107CS5800i, CS6800i, WLW176i, WLW186iboiler8hptw1reservoir temp (TW1)int16 (>=-3199<=3199)Cfalsesensor.boiler_reservoir_temp_(TW1)sensor.boiler_hptw1501/101671
108CS5800i, CS6800i, WLW176i, WLW186iboiler8poolsettemppool set temperatureuint8 (>=0<=127)Ctruenumber.boiler_pool_set_temperaturenumber.boiler_poolsettemp501/21681
109CS5800i, CS6800i, WLW176i, WLW186iboiler8hp4way4-way valve (VR4)enum [cooling & defrost\|heating & dhw]falsesensor.boiler_4-way_valve_(VR4)sensor.boiler_hp4way5011691
110CS5800i, CS6800i, WLW176i, WLW186iboiler8hpin1input 1 statebooleanfalsebinary_sensor.boiler_input_1_statebinary_sensor.boiler_hpin15011701
111CS5800i, CS6800i, WLW176i, WLW186iboiler8hpin1optinput 1 optionsstringtruesensor.boiler_input_1_optionssensor.boiler_hpin1opt5011718
112CS5800i, CS6800i, WLW176i, WLW186iboiler8hpin2input 2 statebooleanfalsebinary_sensor.boiler_input_2_statebinary_sensor.boiler_hpin25011791
113CS5800i, CS6800i, WLW176i, WLW186iboiler8hpin2optinput 2 optionsstringtruesensor.boiler_input_2_optionssensor.boiler_hpin2opt5011808
114CS5800i, CS6800i, WLW176i, WLW186iboiler8hpin3input 3 statebooleanfalsebinary_sensor.boiler_input_3_statebinary_sensor.boiler_hpin35011881
115CS5800i, CS6800i, WLW176i, WLW186iboiler8hpin3optinput 3 optionsstringtruesensor.boiler_input_3_optionssensor.boiler_hpin3opt5011898
116CS5800i, CS6800i, WLW176i, WLW186iboiler8hpin4input 4 statebooleanfalsebinary_sensor.boiler_input_4_statebinary_sensor.boiler_hpin45011971
117CS5800i, CS6800i, WLW176i, WLW186iboiler8hpin4optinput 4 optionsstringtruesensor.boiler_input_4_optionssensor.boiler_hpin4opt5011988
118CS5800i, CS6800i, WLW176i, WLW186iboiler8maxheatcompheat limit compressorenum [0 kW\|3 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_compressorselect.boiler_maxheatcomp5012061
119CS5800i, CS6800i, WLW176i, WLW186iboiler8maxheatheatheat limit heatingenum [3 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_heatingselect.boiler_maxheatheat5012071
120CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.maxheatheat limitenum [3 kW\|6 kW\|9 kW]trueselect.boiler_dhw_heat_limitselect.boiler_dhw_maxheat591141
121CS5800i, CS6800i, WLW176i, WLW186iboiler8auxheatersourceaux heater sourceenum [not installed\|electric heater\|exclusive\|parallel\|hybrid]trueselect.boiler_aux_heater_sourceselect.boiler_auxheatersource5012081
122CS5800i, CS6800i, WLW176i, WLW186iboiler8pvcoolingcooling only with PVbooleantrueswitch.boiler_cooling_only_with_PVswitch.boiler_pvcooling5012091
123CS5800i, CS6800i, WLW176i, WLW186iboiler8auxheateronlyaux heater onlybooleantrueswitch.boiler_aux_heater_onlyswitch.boiler_auxheateronly5012101
124CS5800i, CS6800i, WLW176i, WLW186iboiler8auxheateroffdisable aux heaterbooleantrueswitch.boiler_disable_aux_heaterswitch.boiler_auxheateroff5012111
125CS5800i, CS6800i, WLW176i, WLW186iboiler8auxheaterstatusaux heater statusenum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm]falsesensor.boiler_aux_heater_statussensor.boiler_auxheaterstatus5012121
126CS5800i, CS6800i, WLW176i, WLW186iboiler8auxheaterlevelaux heater leveluint8 (>=0<=100)%falsesensor.boiler_aux_heater_levelsensor.boiler_auxheaterlevel5012131
127CS5800i, CS6800i, WLW176i, WLW186iboiler8auxheaterdelayaux heater on delayuint16 (>=10<=1000)K*mintruenumber.boiler_aux_heater_on_delaynumber.boiler_auxheaterdelay50102141
128CS5800i, CS6800i, WLW176i, WLW186iboiler8auxmaxlimitaux heater max limituint8 (>=0<=10)Ktruenumber.boiler_aux_heater_max_limitnumber.boiler_auxmaxlimit501/102151
129CS5800i, CS6800i, WLW176i, WLW186iboiler8auxlimitstartaux heater limit startuint8 (>=0<=10)Ktruenumber.boiler_aux_heater_limit_startnumber.boiler_auxlimitstart501/102161
130CS5800i, CS6800i, WLW176i, WLW186iboiler8auxheatrmodeaux heater modeenum [eco\|comfort]trueselect.boiler_aux_heater_modeselect.boiler_auxheatrmode5012171
131CS5800i, CS6800i, WLW176i, WLW186iboiler8hphystheaton/off hyst heatuint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_heatnumber.boiler_hphystheat5052181
132CS5800i, CS6800i, WLW176i, WLW186iboiler8hphystcoolon/off hyst cooluint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_coolnumber.boiler_hphystcool5052191
133CS5800i, CS6800i, WLW176i, WLW186iboiler8hphystpoolon/off hyst pooluint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_poolnumber.boiler_hphystpool5052201
134CS5800i, CS6800i, WLW176i, WLW186iboiler8silentmodesilent modeenum [off\|auto\|on]trueselect.boiler_silent_modeselect.boiler_silentmode5012211
135CS5800i, CS6800i, WLW176i, WLW186iboiler8silentfromsilent mode fromuint8 (>=0<=3810)minutestruenumber.boiler_silent_mode_fromnumber.boiler_silentfrom50152221
136CS5800i, CS6800i, WLW176i, WLW186iboiler8silenttosilent mode touint8 (>=0<=3810)minutestruenumber.boiler_silent_mode_tonumber.boiler_silentto50152231
137CS5800i, CS6800i, WLW176i, WLW186iboiler8mintempsilentmin outside temp for silent modeint8 (>=-126<=126)Ctruenumber.boiler_min_outside_temp_for_silent_modenumber.boiler_mintempsilent5012241
138CS5800i, CS6800i, WLW176i, WLW186iboiler8tempparmodeoutside temp parallel modeint8 (>=-126<=126)Ctruenumber.boiler_outside_temp_parallel_modenumber.boiler_tempparmode5012251
139CS5800i, CS6800i, WLW176i, WLW186iboiler8auxheatmixaux heater mixing valveint8 (>=-100<=100)%falsesensor.boiler_aux_heater_mixing_valvesensor.boiler_auxheatmix5012261
140CS5800i, CS6800i, WLW176i, WLW186iboiler8tempdiffheattemp diff TC3/TC0 heatuint8 (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_heatnumber.boiler_tempdiffheat501/102271
141CS5800i, CS6800i, WLW176i, WLW186iboiler8tempdiffcooltemp diff TC3/TC0 cooluint8 (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_coolnumber.boiler_tempdiffcool501/102281
142CS5800i, CS6800i, WLW176i, WLW186iboiler8vpcoolingvalve/pump coolingbooleantrueswitch.boiler_valve/pump_coolingswitch.boiler_vpcooling5012291
143CS5800i, CS6800i, WLW176i, WLW186iboiler8heatcableheating cablebooleantrueswitch.boiler_heating_cableswitch.boiler_heatcable5012301
144CS5800i, CS6800i, WLW176i, WLW186iboiler8vc0valveVC0 valvebooleantrueswitch.boiler_VC0_valveswitch.boiler_vc0valve5012311
145CS5800i, CS6800i, WLW176i, WLW186iboiler8primepumpprimary heatpumpbooleantrueswitch.boiler_primary_heatpumpswitch.boiler_primepump5012321
146CS5800i, CS6800i, WLW176i, WLW186iboiler8primepumpmodprimary heatpump modulationuint8 (>=0<=100)%truenumber.boiler_primary_heatpump_modulationnumber.boiler_primepumpmod5012331
147CS5800i, CS6800i, WLW176i, WLW186iboiler8hp3way3-way valvebooleantrueswitch.boiler_3-way_valveswitch.boiler_hp3way5012341
148CS5800i, CS6800i, WLW176i, WLW186iboiler8elheatstep1el. heater step 1booleantrueswitch.boiler_el._heater_step_1switch.boiler_elheatstep15012351
149CS5800i, CS6800i, WLW176i, WLW186iboiler8elheatstep2el. heater step 2booleantrueswitch.boiler_el._heater_step_2switch.boiler_elheatstep25012361
150CS5800i, CS6800i, WLW176i, WLW186iboiler8elheatstep3el. heater step 3booleantrueswitch.boiler_el._heater_step_3switch.boiler_elheatstep35012371
151CS5800i, CS6800i, WLW176i, WLW186iboiler8hpea0condensate reservoir heating (EA0)booleanfalsebinary_sensor.boiler_condensate_reservoir_heating_(EA0)binary_sensor.boiler_hpea05012381
152CS5800i, CS6800i, WLW176i, WLW186iboiler8hppumpmodeprimary heatpump modeenum [auto\|continuous]trueselect.boiler_primary_heatpump_modeselect.boiler_hppumpmode5012391
153CS5800i, CS6800i, WLW176i, WLW186iboiler8fanfanuint8 (>=20<=100)%truenumber.boiler_fannumber.boiler_fan5012401
154CS5800i, CS6800i, WLW176i, WLW186iboiler8shutdownshutdowncmd [off\|on]truesensor.boiler_shutdownsensor.boiler_shutdown5012411
155CS5800i, CS6800i, WLW176i, WLW186iboiler8hpcurrpowercompressor current poweruint16 (>=0<=31999)Wfalsesensor.boiler_compressor_current_powersensor.boiler_hpcurrpower5012421
156CS5800i, CS6800i, WLW176i, WLW186iboiler8hppowerlimitpower limituint16 (>=0<=31999)Wtruenumber.boiler_power_limitnumber.boiler_hppowerlimit5012431
157CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.alternatingopalternating operationbooleantrueswitch.boiler_dhw_alternating_operationswitch.boiler_dhw_alternatingop591151
158CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.altopprioheatprioritise heating during dhwuint8 (>=20<=120)minutestruenumber.boiler_dhw_prioritise_heating_during_dhwnumber.boiler_dhw_altopprioheat591161
159CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.altopprioprioritise dhw during heatinguint8 (>=30<=120)minutestruenumber.boiler_dhw_prioritise_dhw_during_heatingnumber.boiler_dhw_altopprio591171
160CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.comfoffcomfort switch offuint8 (>=15<=65)Ctruenumber.boiler_dhw_comfort_switch_offnumber.boiler_dhw_comfoff591181
161CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.ecooffeco switch offuint8 (>=15<=65)Ctruenumber.boiler_dhw_eco_switch_offnumber.boiler_dhw_ecooff591191
162CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.ecoplusoffeco+ switch offuint8 (>=48<=63)Ctruenumber.boiler_dhw_eco+_switch_offnumber.boiler_dhw_ecoplusoff591201
163CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.comfdiffcomfort diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_comfort_diffnumber.boiler_dhw_comfdiff591211
164CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.ecodiffeco diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_eco_diffnumber.boiler_dhw_ecodiff591221
165CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.ecoplusdiffeco+ diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_eco+_diffnumber.boiler_dhw_ecoplusdiff591231
166CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.comfstopcomfort stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_comfort_stop_tempnumber.boiler_dhw_comfstop591241
167CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.ecostopeco stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_eco_stop_tempnumber.boiler_dhw_ecostop591251
168CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.ecoplusstopeco+ stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_eco+_stop_tempnumber.boiler_dhw_ecoplusstop591261
169CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.hpcircpumpcirculation pump available during dhwbooleantrueswitch.boiler_dhw_circulation_pump_available_during_dhwswitch.boiler_dhw_hpcircpump591271
170CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
171CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
172CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
173CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
174CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
175CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
176CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
177CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
178CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
179CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
180CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
181CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
182CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
183CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
184CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
185CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
186CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
187CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
188CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
189CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
190CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
191CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
192CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
193CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
194CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
195CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
196CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
197CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
198CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
199CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
200CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
201CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
202CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
203CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
204CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
205CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
206CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
207CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
208CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
209CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
210C1200Wboiler12resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
211C1200Wboiler12heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
212C1200Wboiler12heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
213C1200Wboiler12tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
214C1200Wboiler12selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
215C1200Wboiler12heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
216C1200Wboiler12outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
217C1200Wboiler12curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
218C1200Wboiler12rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
219C1200Wboiler12switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
220C1200Wboiler12syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
221C1200Wboiler12boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
222C1200Wboiler12headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
223C1200Wboiler12exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
224C1200Wboiler12burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
225C1200Wboiler12burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
226C1200Wboiler12flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
227C1200Wboiler12fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
228C1200Wboiler12ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
229C1200Wboiler12oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
230C1200Wboiler12burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
231C1200Wboiler12burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
232C1200Wboiler12burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
233C1200Wboiler12absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
234C1200Wboiler12heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
235C1200Wboiler12boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
236C1200Wboiler12boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
237C1200Wboiler12boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
238C1200Wboiler12boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
239C1200Wboiler12curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
240C1200Wboiler12curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
241C1200Wboiler12curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
242C1200Wboiler12summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
243C1200Wboiler12nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
244C1200Wboiler12nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
245C1200Wboiler12heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
246C1200Wboiler12heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
247C1200Wboiler12heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
248C1200Wboiler12pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
249C1200Wboiler12pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
250C1200Wboiler12pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
251C1200Wboiler12pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
252C1200Wboiler12pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
253C1200Wboiler12pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
254C1200Wboiler12selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
255C1200Wboiler12curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
256C1200Wboiler12burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
257C1200Wboiler12burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
258C1200Wboiler12burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
259C1200Wboiler12heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
260C1200Wboiler12heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
261C1200Wboiler12ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
262C1200Wboiler12lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
263C1200Wboiler12servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
264C1200Wboiler12servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
265C1200Wboiler12maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
266C1200Wboiler12maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
267C1200Wboiler12maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
268C1200Wboiler12maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
269C1200Wboiler12emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
270C1200Wboiler12emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
271C1200Wboiler12pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
272C1200Wboiler12pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
273C1200Wboiler12pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
274C1200Wboiler12pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
275C1200Wboiler12meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
276C1200Wboiler12dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
277C1200Wboiler12gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
278C1200Wboiler12dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
279C1200Wboiler12nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
280C1200Wboiler12dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
281C1200Wboiler12dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
282C1200Wboiler12dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
283C1200Wboiler12dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
284C1200Wboiler12dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
285C1200Wboiler12dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
286C1200Wboiler12dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
287C1200Wboiler12dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
288C1200Wboiler12dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
289C1200Wboiler12dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
290C1200Wboiler12dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
291C1200Wboiler12dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
292C1200Wboiler12dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
293C1200Wboiler12dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
294C1200Wboiler12dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
295C1200Wboiler12dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
296C1200Wboiler12dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
297C1200Wboiler12dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
298C1200Wboiler12dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
299C1200Wboiler12dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
300C1200Wboiler12dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
301C1200Wboiler12dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
302C1200Wboiler12dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
303C1200Wboiler12dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
304C1200Wboiler12dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
305C1200Wboiler12dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
306C1200Wboiler12dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
307C1200Wboiler12dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
308C1200Wboiler12dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
309C1200Wboiler12dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
310C1200Wboiler12dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
311C1200Wboiler12dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
312C1200Wboiler12dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
313C1200Wboiler12dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
314C1200Wboiler12dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
315C1200Wboiler12dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
316C1200Wboiler12dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
317C1200Wboiler12dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
318C1200Wboiler12dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
319C1200Wboiler12dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
320C1200Wboiler12dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
321C1200Wboiler12nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
322C1200Wboiler12nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
323C1200Wboiler12nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
324C1200Wboiler12dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
325BK13/BK15, Smartline, GB1*2boiler64resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
326BK13/BK15, Smartline, GB1*2boiler64heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
327BK13/BK15, Smartline, GB1*2boiler64heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
328BK13/BK15, Smartline, GB1*2boiler64tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
329BK13/BK15, Smartline, GB1*2boiler64selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
330BK13/BK15, Smartline, GB1*2boiler64heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
331BK13/BK15, Smartline, GB1*2boiler64outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
332BK13/BK15, Smartline, GB1*2boiler64curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
333BK13/BK15, Smartline, GB1*2boiler64rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
334BK13/BK15, Smartline, GB1*2boiler64switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
335BK13/BK15, Smartline, GB1*2boiler64syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
336BK13/BK15, Smartline, GB1*2boiler64boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
337BK13/BK15, Smartline, GB1*2boiler64headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
338BK13/BK15, Smartline, GB1*2boiler64exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
339BK13/BK15, Smartline, GB1*2boiler64burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
340BK13/BK15, Smartline, GB1*2boiler64burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
341BK13/BK15, Smartline, GB1*2boiler64flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
342BK13/BK15, Smartline, GB1*2boiler64fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
343BK13/BK15, Smartline, GB1*2boiler64ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
344BK13/BK15, Smartline, GB1*2boiler64oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
345BK13/BK15, Smartline, GB1*2boiler64burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
346BK13/BK15, Smartline, GB1*2boiler64burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
347BK13/BK15, Smartline, GB1*2boiler64burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
348BK13/BK15, Smartline, GB1*2boiler64absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
349BK13/BK15, Smartline, GB1*2boiler64heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
350BK13/BK15, Smartline, GB1*2boiler64boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
351BK13/BK15, Smartline, GB1*2boiler64boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
352BK13/BK15, Smartline, GB1*2boiler64boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
353BK13/BK15, Smartline, GB1*2boiler64boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
354BK13/BK15, Smartline, GB1*2boiler64curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
355BK13/BK15, Smartline, GB1*2boiler64curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
356BK13/BK15, Smartline, GB1*2boiler64curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
357BK13/BK15, Smartline, GB1*2boiler64summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
358BK13/BK15, Smartline, GB1*2boiler64nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
359BK13/BK15, Smartline, GB1*2boiler64nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
360BK13/BK15, Smartline, GB1*2boiler64heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
361BK13/BK15, Smartline, GB1*2boiler64heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
362BK13/BK15, Smartline, GB1*2boiler64heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
363BK13/BK15, Smartline, GB1*2boiler64pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
364BK13/BK15, Smartline, GB1*2boiler64pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
365BK13/BK15, Smartline, GB1*2boiler64pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
366BK13/BK15, Smartline, GB1*2boiler64pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
367BK13/BK15, Smartline, GB1*2boiler64pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
368BK13/BK15, Smartline, GB1*2boiler64pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
369BK13/BK15, Smartline, GB1*2boiler64selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
370BK13/BK15, Smartline, GB1*2boiler64curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
371BK13/BK15, Smartline, GB1*2boiler64burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
372BK13/BK15, Smartline, GB1*2boiler64burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
373BK13/BK15, Smartline, GB1*2boiler64burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
374BK13/BK15, Smartline, GB1*2boiler64heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
375BK13/BK15, Smartline, GB1*2boiler64heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
376BK13/BK15, Smartline, GB1*2boiler64ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
377BK13/BK15, Smartline, GB1*2boiler64lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
378BK13/BK15, Smartline, GB1*2boiler64servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
379BK13/BK15, Smartline, GB1*2boiler64servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
380BK13/BK15, Smartline, GB1*2boiler64maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
381BK13/BK15, Smartline, GB1*2boiler64maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
382BK13/BK15, Smartline, GB1*2boiler64maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
383BK13/BK15, Smartline, GB1*2boiler64maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
384BK13/BK15, Smartline, GB1*2boiler64emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
385BK13/BK15, Smartline, GB1*2boiler64emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
386BK13/BK15, Smartline, GB1*2boiler64pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
387BK13/BK15, Smartline, GB1*2boiler64pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
388BK13/BK15, Smartline, GB1*2boiler64pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
389BK13/BK15, Smartline, GB1*2boiler64pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
390BK13/BK15, Smartline, GB1*2boiler64meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
391BK13/BK15, Smartline, GB1*2boiler64dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
392BK13/BK15, Smartline, GB1*2boiler64gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
393BK13/BK15, Smartline, GB1*2boiler64dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
394BK13/BK15, Smartline, GB1*2boiler64nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
395BK13/BK15, Smartline, GB1*2boiler64dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
396BK13/BK15, Smartline, GB1*2boiler64dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
397BK13/BK15, Smartline, GB1*2boiler64dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
398BK13/BK15, Smartline, GB1*2boiler64dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
399BK13/BK15, Smartline, GB1*2boiler64dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
400BK13/BK15, Smartline, GB1*2boiler64dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
401BK13/BK15, Smartline, GB1*2boiler64dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
402BK13/BK15, Smartline, GB1*2boiler64dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
403BK13/BK15, Smartline, GB1*2boiler64dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
404BK13/BK15, Smartline, GB1*2boiler64dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
405BK13/BK15, Smartline, GB1*2boiler64dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
406BK13/BK15, Smartline, GB1*2boiler64dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
407BK13/BK15, Smartline, GB1*2boiler64dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
408BK13/BK15, Smartline, GB1*2boiler64dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
409BK13/BK15, Smartline, GB1*2boiler64dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
410BK13/BK15, Smartline, GB1*2boiler64dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
411BK13/BK15, Smartline, GB1*2boiler64dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
412BK13/BK15, Smartline, GB1*2boiler64dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
413BK13/BK15, Smartline, GB1*2boiler64dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
414BK13/BK15, Smartline, GB1*2boiler64dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
415BK13/BK15, Smartline, GB1*2boiler64dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
416BK13/BK15, Smartline, GB1*2boiler64dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
417BK13/BK15, Smartline, GB1*2boiler64dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
418BK13/BK15, Smartline, GB1*2boiler64dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
419BK13/BK15, Smartline, GB1*2boiler64dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
420BK13/BK15, Smartline, GB1*2boiler64dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
421BK13/BK15, Smartline, GB1*2boiler64dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
422BK13/BK15, Smartline, GB1*2boiler64dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
423BK13/BK15, Smartline, GB1*2boiler64dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
424BK13/BK15, Smartline, GB1*2boiler64dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
425BK13/BK15, Smartline, GB1*2boiler64dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
426BK13/BK15, Smartline, GB1*2boiler64dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
427BK13/BK15, Smartline, GB1*2boiler64dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
428BK13/BK15, Smartline, GB1*2boiler64dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
429BK13/BK15, Smartline, GB1*2boiler64dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
430BK13/BK15, Smartline, GB1*2boiler64dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
431BK13/BK15, Smartline, GB1*2boiler64dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
432BK13/BK15, Smartline, GB1*2boiler64dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
433BK13/BK15, Smartline, GB1*2boiler64dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
434BK13/BK15, Smartline, GB1*2boiler64dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
435BK13/BK15, Smartline, GB1*2boiler64dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
436BK13/BK15, Smartline, GB1*2boiler64nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
437BK13/BK15, Smartline, GB1*2boiler64nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
438BK13/BK15, Smartline, GB1*2boiler64nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
439BK13/BK15, Smartline, GB1*2boiler64dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
440Logano GB1*5, Logamatic MC10boiler72resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
441Logano GB1*5, Logamatic MC10boiler72heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
442Logano GB1*5, Logamatic MC10boiler72heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
443Logano GB1*5, Logamatic MC10boiler72tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
444Logano GB1*5, Logamatic MC10boiler72selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
445Logano GB1*5, Logamatic MC10boiler72heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
446Logano GB1*5, Logamatic MC10boiler72outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
447Logano GB1*5, Logamatic MC10boiler72curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
448Logano GB1*5, Logamatic MC10boiler72rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
449Logano GB1*5, Logamatic MC10boiler72switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
450Logano GB1*5, Logamatic MC10boiler72syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
451Logano GB1*5, Logamatic MC10boiler72boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
452Logano GB1*5, Logamatic MC10boiler72headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
453Logano GB1*5, Logamatic MC10boiler72exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
454Logano GB1*5, Logamatic MC10boiler72burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
455Logano GB1*5, Logamatic MC10boiler72burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
456Logano GB1*5, Logamatic MC10boiler72flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
457Logano GB1*5, Logamatic MC10boiler72fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
458Logano GB1*5, Logamatic MC10boiler72ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
459Logano GB1*5, Logamatic MC10boiler72oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
460Logano GB1*5, Logamatic MC10boiler72burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
461Logano GB1*5, Logamatic MC10boiler72burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
462Logano GB1*5, Logamatic MC10boiler72burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
463Logano GB1*5, Logamatic MC10boiler72absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
464Logano GB1*5, Logamatic MC10boiler72heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
465Logano GB1*5, Logamatic MC10boiler72boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
466Logano GB1*5, Logamatic MC10boiler72boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
467Logano GB1*5, Logamatic MC10boiler72boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
468Logano GB1*5, Logamatic MC10boiler72boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
469Logano GB1*5, Logamatic MC10boiler72curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
470Logano GB1*5, Logamatic MC10boiler72curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
471Logano GB1*5, Logamatic MC10boiler72curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
472Logano GB1*5, Logamatic MC10boiler72summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
473Logano GB1*5, Logamatic MC10boiler72nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
474Logano GB1*5, Logamatic MC10boiler72nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
475Logano GB1*5, Logamatic MC10boiler72heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
476Logano GB1*5, Logamatic MC10boiler72heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
477Logano GB1*5, Logamatic MC10boiler72heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
478Logano GB1*5, Logamatic MC10boiler72pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
479Logano GB1*5, Logamatic MC10boiler72pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
480Logano GB1*5, Logamatic MC10boiler72pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
481Logano GB1*5, Logamatic MC10boiler72pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
482Logano GB1*5, Logamatic MC10boiler72pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
483Logano GB1*5, Logamatic MC10boiler72pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
484Logano GB1*5, Logamatic MC10boiler72selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
485Logano GB1*5, Logamatic MC10boiler72curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
486Logano GB1*5, Logamatic MC10boiler72burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
487Logano GB1*5, Logamatic MC10boiler72burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
488Logano GB1*5, Logamatic MC10boiler72burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
489Logano GB1*5, Logamatic MC10boiler72heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
490Logano GB1*5, Logamatic MC10boiler72heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
491Logano GB1*5, Logamatic MC10boiler72ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
492Logano GB1*5, Logamatic MC10boiler72lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
493Logano GB1*5, Logamatic MC10boiler72servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
494Logano GB1*5, Logamatic MC10boiler72servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
495Logano GB1*5, Logamatic MC10boiler72maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
496Logano GB1*5, Logamatic MC10boiler72maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
497Logano GB1*5, Logamatic MC10boiler72maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
498Logano GB1*5, Logamatic MC10boiler72maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
499Logano GB1*5, Logamatic MC10boiler72emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
500Logano GB1*5, Logamatic MC10boiler72emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
501Logano GB1*5, Logamatic MC10boiler72pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
502Logano GB1*5, Logamatic MC10boiler72pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
503Logano GB1*5, Logamatic MC10boiler72pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
504Logano GB1*5, Logamatic MC10boiler72pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
505Logano GB1*5, Logamatic MC10boiler72meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
506Logano GB1*5, Logamatic MC10boiler72dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
507Logano GB1*5, Logamatic MC10boiler72gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
508Logano GB1*5, Logamatic MC10boiler72dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
509Logano GB1*5, Logamatic MC10boiler72nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
510Logano GB1*5, Logamatic MC10boiler72dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
511Logano GB1*5, Logamatic MC10boiler72dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
512Logano GB1*5, Logamatic MC10boiler72dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
513Logano GB1*5, Logamatic MC10boiler72dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
514Logano GB1*5, Logamatic MC10boiler72dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
515Logano GB1*5, Logamatic MC10boiler72dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
516Logano GB1*5, Logamatic MC10boiler72dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
517Logano GB1*5, Logamatic MC10boiler72dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
518Logano GB1*5, Logamatic MC10boiler72dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
519Logano GB1*5, Logamatic MC10boiler72dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
520Logano GB1*5, Logamatic MC10boiler72dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
521Logano GB1*5, Logamatic MC10boiler72dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
522Logano GB1*5, Logamatic MC10boiler72dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
523Logano GB1*5, Logamatic MC10boiler72dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
524Logano GB1*5, Logamatic MC10boiler72dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
525Logano GB1*5, Logamatic MC10boiler72dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
526Logano GB1*5, Logamatic MC10boiler72dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
527Logano GB1*5, Logamatic MC10boiler72dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
528Logano GB1*5, Logamatic MC10boiler72dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
529Logano GB1*5, Logamatic MC10boiler72dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
530Logano GB1*5, Logamatic MC10boiler72dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
531Logano GB1*5, Logamatic MC10boiler72dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
532Logano GB1*5, Logamatic MC10boiler72dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
533Logano GB1*5, Logamatic MC10boiler72dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
534Logano GB1*5, Logamatic MC10boiler72dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
535Logano GB1*5, Logamatic MC10boiler72dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
536Logano GB1*5, Logamatic MC10boiler72dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
537Logano GB1*5, Logamatic MC10boiler72dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
538Logano GB1*5, Logamatic MC10boiler72dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
539Logano GB1*5, Logamatic MC10boiler72dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
540Logano GB1*5, Logamatic MC10boiler72dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
541Logano GB1*5, Logamatic MC10boiler72dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
542Logano GB1*5, Logamatic MC10boiler72dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
543Logano GB1*5, Logamatic MC10boiler72dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
544Logano GB1*5, Logamatic MC10boiler72dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
545Logano GB1*5, Logamatic MC10boiler72dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
546Logano GB1*5, Logamatic MC10boiler72dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
547Logano GB1*5, Logamatic MC10boiler72dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
548Logano GB1*5, Logamatic MC10boiler72dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
549Logano GB1*5, Logamatic MC10boiler72dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
550Logano GB1*5, Logamatic MC10boiler72dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
551Logano GB1*5, Logamatic MC10boiler72nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
552Logano GB1*5, Logamatic MC10boiler72nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
553Logano GB1*5, Logamatic MC10boiler72nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
554Logano GB1*5, Logamatic MC10boiler72dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
555Cascade CM10boiler81resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
556Cascade CM10boiler81heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
557Cascade CM10boiler81heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
558Cascade CM10boiler81tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
559Cascade CM10boiler81selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
560Cascade CM10boiler81heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
561Cascade CM10boiler81outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
562Cascade CM10boiler81curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
563Cascade CM10boiler81rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
564Cascade CM10boiler81switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
565Cascade CM10boiler81syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
566Cascade CM10boiler81boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
567Cascade CM10boiler81headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
568Cascade CM10boiler81exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
569Cascade CM10boiler81burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
570Cascade CM10boiler81burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
571Cascade CM10boiler81flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
572Cascade CM10boiler81fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
573Cascade CM10boiler81ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
574Cascade CM10boiler81oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
575Cascade CM10boiler81burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
576Cascade CM10boiler81burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
577Cascade CM10boiler81burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
578Cascade CM10boiler81absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
579Cascade CM10boiler81heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
580Cascade CM10boiler81boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
581Cascade CM10boiler81boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
582Cascade CM10boiler81boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
583Cascade CM10boiler81boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
584Cascade CM10boiler81curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
585Cascade CM10boiler81curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
586Cascade CM10boiler81curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
587Cascade CM10boiler81summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
588Cascade CM10boiler81nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
589Cascade CM10boiler81nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
590Cascade CM10boiler81heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
591Cascade CM10boiler81heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
592Cascade CM10boiler81heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
593Cascade CM10boiler81pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
594Cascade CM10boiler81pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
595Cascade CM10boiler81pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
596Cascade CM10boiler81pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
597Cascade CM10boiler81pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
598Cascade CM10boiler81pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
599Cascade CM10boiler81selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
600Cascade CM10boiler81curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
601Cascade CM10boiler81burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
602Cascade CM10boiler81burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
603Cascade CM10boiler81burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
604Cascade CM10boiler81heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
605Cascade CM10boiler81heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
606Cascade CM10boiler81ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
607Cascade CM10boiler81lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
608Cascade CM10boiler81servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
609Cascade CM10boiler81servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
610Cascade CM10boiler81maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
611Cascade CM10boiler81maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
612Cascade CM10boiler81maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
613Cascade CM10boiler81maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
614Cascade CM10boiler81emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
615Cascade CM10boiler81emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
616Cascade CM10boiler81pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
617Cascade CM10boiler81pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
618Cascade CM10boiler81pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
619Cascade CM10boiler81pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
620Cascade CM10boiler81meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
621Cascade CM10boiler81dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
622Cascade CM10boiler81gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
623Cascade CM10boiler81dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
624Cascade CM10boiler81nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
625Cascade CM10boiler81dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
626Cascade CM10boiler81dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
627Cascade CM10boiler81dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
628Cascade CM10boiler81dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
629Cascade CM10boiler81dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
630Cascade CM10boiler81dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
631Cascade CM10boiler81dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
632Cascade CM10boiler81dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
633Cascade CM10boiler81dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
634Cascade CM10boiler81dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
635Cascade CM10boiler81dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
636Cascade CM10boiler81dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
637Cascade CM10boiler81dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
638Cascade CM10boiler81dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
639Cascade CM10boiler81dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
640Cascade CM10boiler81dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
641Cascade CM10boiler81dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
642Cascade CM10boiler81dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
643Cascade CM10boiler81dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
644Cascade CM10boiler81dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
645Cascade CM10boiler81dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
646Cascade CM10boiler81dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
647Cascade CM10boiler81dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
648Cascade CM10boiler81dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
649Cascade CM10boiler81dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
650Cascade CM10boiler81dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
651Cascade CM10boiler81dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
652Cascade CM10boiler81dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
653Cascade CM10boiler81dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
654Cascade CM10boiler81dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
655Cascade CM10boiler81dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
656Cascade CM10boiler81dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
657Cascade CM10boiler81dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
658Cascade CM10boiler81dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
659Cascade CM10boiler81dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
660Cascade CM10boiler81dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
661Cascade CM10boiler81dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
662Cascade CM10boiler81dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
663Cascade CM10boiler81dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
664Cascade CM10boiler81dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
665Cascade CM10boiler81dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
666Cascade CM10boiler81nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
667Cascade CM10boiler81nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
668Cascade CM10boiler81nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
669Cascade CM10boiler81dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
670Logamax Plus GB022boiler84resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
671Logamax Plus GB022boiler84heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
672Logamax Plus GB022boiler84heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
673Logamax Plus GB022boiler84tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
674Logamax Plus GB022boiler84selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
675Logamax Plus GB022boiler84heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
676Logamax Plus GB022boiler84outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
677Logamax Plus GB022boiler84curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
678Logamax Plus GB022boiler84rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
679Logamax Plus GB022boiler84switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
680Logamax Plus GB022boiler84syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
681Logamax Plus GB022boiler84boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
682Logamax Plus GB022boiler84headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
683Logamax Plus GB022boiler84exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
684Logamax Plus GB022boiler84burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
685Logamax Plus GB022boiler84burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
686Logamax Plus GB022boiler84flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
687Logamax Plus GB022boiler84fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
688Logamax Plus GB022boiler84ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
689Logamax Plus GB022boiler84oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
690Logamax Plus GB022boiler84burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
691Logamax Plus GB022boiler84burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
692Logamax Plus GB022boiler84burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
693Logamax Plus GB022boiler84absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
694Logamax Plus GB022boiler84heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
695Logamax Plus GB022boiler84boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
696Logamax Plus GB022boiler84boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
697Logamax Plus GB022boiler84boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
698Logamax Plus GB022boiler84boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
699Logamax Plus GB022boiler84curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
700Logamax Plus GB022boiler84curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
701Logamax Plus GB022boiler84curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
702Logamax Plus GB022boiler84summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
703Logamax Plus GB022boiler84nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
704Logamax Plus GB022boiler84nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
705Logamax Plus GB022boiler84heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
706Logamax Plus GB022boiler84heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
707Logamax Plus GB022boiler84heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
708Logamax Plus GB022boiler84pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
709Logamax Plus GB022boiler84pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
710Logamax Plus GB022boiler84pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
711Logamax Plus GB022boiler84pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
712Logamax Plus GB022boiler84pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
713Logamax Plus GB022boiler84pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
714Logamax Plus GB022boiler84selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
715Logamax Plus GB022boiler84curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
716Logamax Plus GB022boiler84burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
717Logamax Plus GB022boiler84burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
718Logamax Plus GB022boiler84burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
719Logamax Plus GB022boiler84heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
720Logamax Plus GB022boiler84heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
721Logamax Plus GB022boiler84ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
722Logamax Plus GB022boiler84lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
723Logamax Plus GB022boiler84servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
724Logamax Plus GB022boiler84servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
725Logamax Plus GB022boiler84maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
726Logamax Plus GB022boiler84maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
727Logamax Plus GB022boiler84maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
728Logamax Plus GB022boiler84maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
729Logamax Plus GB022boiler84emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
730Logamax Plus GB022boiler84emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
731Logamax Plus GB022boiler84pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
732Logamax Plus GB022boiler84pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
733Logamax Plus GB022boiler84pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
734Logamax Plus GB022boiler84pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
735Logamax Plus GB022boiler84meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
736Logamax Plus GB022boiler84dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
737Logamax Plus GB022boiler84gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
738Logamax Plus GB022boiler84dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
739Logamax Plus GB022boiler84nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
740Logamax Plus GB022boiler84dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
741Logamax Plus GB022boiler84dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
742Logamax Plus GB022boiler84dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
743Logamax Plus GB022boiler84dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
744Logamax Plus GB022boiler84dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
745Logamax Plus GB022boiler84dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
746Logamax Plus GB022boiler84dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
747Logamax Plus GB022boiler84dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
748Logamax Plus GB022boiler84dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
749Logamax Plus GB022boiler84dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
750Logamax Plus GB022boiler84dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
751Logamax Plus GB022boiler84dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
752Logamax Plus GB022boiler84dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
753Logamax Plus GB022boiler84dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
754Logamax Plus GB022boiler84dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
755Logamax Plus GB022boiler84dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
756Logamax Plus GB022boiler84dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
757Logamax Plus GB022boiler84dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
758Logamax Plus GB022boiler84dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
759Logamax Plus GB022boiler84dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
760Logamax Plus GB022boiler84dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
761Logamax Plus GB022boiler84dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
762Logamax Plus GB022boiler84dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
763Logamax Plus GB022boiler84dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
764Logamax Plus GB022boiler84dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
765Logamax Plus GB022boiler84dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
766Logamax Plus GB022boiler84dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
767Logamax Plus GB022boiler84dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
768Logamax Plus GB022boiler84dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
769Logamax Plus GB022boiler84dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
770Logamax Plus GB022boiler84dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
771Logamax Plus GB022boiler84dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
772Logamax Plus GB022boiler84dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
773Logamax Plus GB022boiler84dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
774Logamax Plus GB022boiler84dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
775Logamax Plus GB022boiler84dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
776Logamax Plus GB022boiler84dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
777Logamax Plus GB022boiler84dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
778Logamax Plus GB022boiler84dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
779Logamax Plus GB022boiler84dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
780Logamax Plus GB022boiler84dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
781Logamax Plus GB022boiler84nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
782Logamax Plus GB022boiler84nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
783Logamax Plus GB022boiler84nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
784Logamax Plus GB022boiler84dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
785Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
786Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
787Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
788Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
789Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
790Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
791Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
792Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
793Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
794Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
795Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
796Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
797Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
798Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
799Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
800Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
801Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
802Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
803Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
804Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
805Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
806Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
807Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
808Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
809Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
810Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
811Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
812Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
813Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
814Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
815Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
816Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
817Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
818Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
819Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
820Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
821Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
822Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
823Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
824Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
825Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
826Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
827Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
828Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
829Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
830Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
831Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
832Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
833Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
834Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
835Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
836Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
837Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
838Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
839Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
840Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
841Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
842Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
843Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
844Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
845Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
846Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
847Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
848Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
849Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
850Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
851Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
852Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
853Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
854Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
855Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
856Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
857Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
858Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
859Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
860Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
861Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
862Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
863Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
864Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
865Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
866Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
867Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
868Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
869Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
870Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
871Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
872Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
873Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
874Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
875Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
876Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
877Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
878Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
879Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
880Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
881Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
882Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
883Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
884Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
885Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
886Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
887Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
888Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
889Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
890Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
891Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
892Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
893Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
894Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
895Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
896Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
897Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
898Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
899Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
900Topline, GB162boiler115resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
901Topline, GB162boiler115heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
902Topline, GB162boiler115heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
903Topline, GB162boiler115tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
904Topline, GB162boiler115selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
905Topline, GB162boiler115heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
906Topline, GB162boiler115outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
907Topline, GB162boiler115curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
908Topline, GB162boiler115rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
909Topline, GB162boiler115switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
910Topline, GB162boiler115syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
911Topline, GB162boiler115boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
912Topline, GB162boiler115headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
913Topline, GB162boiler115exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
914Topline, GB162boiler115burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
915Topline, GB162boiler115burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
916Topline, GB162boiler115flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
917Topline, GB162boiler115fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
918Topline, GB162boiler115ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
919Topline, GB162boiler115oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
920Topline, GB162boiler115burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
921Topline, GB162boiler115burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
922Topline, GB162boiler115burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
923Topline, GB162boiler115absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
924Topline, GB162boiler115heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
925Topline, GB162boiler115boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
926Topline, GB162boiler115boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
927Topline, GB162boiler115boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
928Topline, GB162boiler115boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
929Topline, GB162boiler115curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
930Topline, GB162boiler115curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
931Topline, GB162boiler115curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
932Topline, GB162boiler115summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
933Topline, GB162boiler115nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
934Topline, GB162boiler115nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
935Topline, GB162boiler115heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
936Topline, GB162boiler115heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
937Topline, GB162boiler115heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
938Topline, GB162boiler115pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
939Topline, GB162boiler115pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
940Topline, GB162boiler115pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
941Topline, GB162boiler115pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
942Topline, GB162boiler115pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
943Topline, GB162boiler115pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
944Topline, GB162boiler115selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
945Topline, GB162boiler115curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
946Topline, GB162boiler115burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
947Topline, GB162boiler115burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
948Topline, GB162boiler115burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
949Topline, GB162boiler115heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
950Topline, GB162boiler115heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
951Topline, GB162boiler115ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
952Topline, GB162boiler115lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
953Topline, GB162boiler115servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
954Topline, GB162boiler115servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
955Topline, GB162boiler115maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
956Topline, GB162boiler115maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
957Topline, GB162boiler115maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
958Topline, GB162boiler115maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
959Topline, GB162boiler115emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
960Topline, GB162boiler115emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
961Topline, GB162boiler115pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
962Topline, GB162boiler115pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
963Topline, GB162boiler115pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
964Topline, GB162boiler115pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
965Topline, GB162boiler115meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
966Topline, GB162boiler115dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
967Topline, GB162boiler115gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
968Topline, GB162boiler115dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
969Topline, GB162boiler115nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
970Topline, GB162boiler115dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
971Topline, GB162boiler115dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
972Topline, GB162boiler115dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
973Topline, GB162boiler115dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
974Topline, GB162boiler115dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
975Topline, GB162boiler115dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
976Topline, GB162boiler115dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
977Topline, GB162boiler115dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
978Topline, GB162boiler115dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
979Topline, GB162boiler115dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
980Topline, GB162boiler115dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
981Topline, GB162boiler115dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
982Topline, GB162boiler115dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
983Topline, GB162boiler115dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
984Topline, GB162boiler115dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
985Topline, GB162boiler115dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
986Topline, GB162boiler115dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
987Topline, GB162boiler115dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
988Topline, GB162boiler115dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
989Topline, GB162boiler115dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
990Topline, GB162boiler115dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
991Topline, GB162boiler115dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
992Topline, GB162boiler115dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
993Topline, GB162boiler115dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
994Topline, GB162boiler115dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
995Topline, GB162boiler115dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
996Topline, GB162boiler115dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
997Topline, GB162boiler115dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
998Topline, GB162boiler115dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
999Topline, GB162boiler115dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1000Topline, GB162boiler115dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1001Topline, GB162boiler115dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1002Topline, GB162boiler115dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1003Topline, GB162boiler115dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1004Topline, GB162boiler115dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1005Topline, GB162boiler115dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1006Topline, GB162boiler115dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
1007Topline, GB162boiler115dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1008Topline, GB162boiler115dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1009Topline, GB162boiler115dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1010Topline, GB162boiler115dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1011Topline, GB162boiler115nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1012Topline, GB162boiler115nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1013Topline, GB162boiler115nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1014Topline, GB162boiler115dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1015Cascade MCM10boiler121resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1016Cascade MCM10boiler121heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1017Cascade MCM10boiler121heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1018Cascade MCM10boiler121tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1019Cascade MCM10boiler121selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1020Cascade MCM10boiler121heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1021Cascade MCM10boiler121outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1022Cascade MCM10boiler121curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1023Cascade MCM10boiler121rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1024Cascade MCM10boiler121switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1025Cascade MCM10boiler121syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1026Cascade MCM10boiler121boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1027Cascade MCM10boiler121headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1028Cascade MCM10boiler121exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1029Cascade MCM10boiler121burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1030Cascade MCM10boiler121burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1031Cascade MCM10boiler121flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1032Cascade MCM10boiler121fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1033Cascade MCM10boiler121ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1034Cascade MCM10boiler121oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1035Cascade MCM10boiler121burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1036Cascade MCM10boiler121burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1037Cascade MCM10boiler121burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1038Cascade MCM10boiler121absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1039Cascade MCM10boiler121heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1040Cascade MCM10boiler121boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1041Cascade MCM10boiler121boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1042Cascade MCM10boiler121boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1043Cascade MCM10boiler121boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1044Cascade MCM10boiler121curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1045Cascade MCM10boiler121curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1046Cascade MCM10boiler121curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1047Cascade MCM10boiler121summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1048Cascade MCM10boiler121nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1049Cascade MCM10boiler121nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1050Cascade MCM10boiler121heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1051Cascade MCM10boiler121heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1052Cascade MCM10boiler121heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1053Cascade MCM10boiler121pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1054Cascade MCM10boiler121pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1055Cascade MCM10boiler121pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1056Cascade MCM10boiler121pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1057Cascade MCM10boiler121pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1058Cascade MCM10boiler121pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1059Cascade MCM10boiler121selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1060Cascade MCM10boiler121curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1061Cascade MCM10boiler121burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1062Cascade MCM10boiler121burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1063Cascade MCM10boiler121burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1064Cascade MCM10boiler121heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1065Cascade MCM10boiler121heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1066Cascade MCM10boiler121ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1067Cascade MCM10boiler121lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1068Cascade MCM10boiler121servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1069Cascade MCM10boiler121servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1070Cascade MCM10boiler121maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1071Cascade MCM10boiler121maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1072Cascade MCM10boiler121maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1073Cascade MCM10boiler121maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1074Cascade MCM10boiler121emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1075Cascade MCM10boiler121emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1076Cascade MCM10boiler121pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1077Cascade MCM10boiler121pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1078Cascade MCM10boiler121pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1079Cascade MCM10boiler121pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1080Cascade MCM10boiler121meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1081Cascade MCM10boiler121dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1082Cascade MCM10boiler121gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1083Cascade MCM10boiler121dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1084Cascade MCM10boiler121nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1085Cascade MCM10boiler121dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1086Cascade MCM10boiler121dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1087Cascade MCM10boiler121dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1088Cascade MCM10boiler121dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1089Cascade MCM10boiler121dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1090Cascade MCM10boiler121dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1091Cascade MCM10boiler121dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1092Cascade MCM10boiler121dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1093Cascade MCM10boiler121dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1094Cascade MCM10boiler121dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1095Cascade MCM10boiler121dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1096Cascade MCM10boiler121dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1097Cascade MCM10boiler121dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1098Cascade MCM10boiler121dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1099Cascade MCM10boiler121dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1100Cascade MCM10boiler121dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1101Cascade MCM10boiler121dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1102Cascade MCM10boiler121dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1103Cascade MCM10boiler121dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1104Cascade MCM10boiler121dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1105Cascade MCM10boiler121dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1106Cascade MCM10boiler121dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1107Cascade MCM10boiler121dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1108Cascade MCM10boiler121dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1109Cascade MCM10boiler121dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1110Cascade MCM10boiler121dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1111Cascade MCM10boiler121dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1112Cascade MCM10boiler121dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1113Cascade MCM10boiler121dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1114Cascade MCM10boiler121dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1115Cascade MCM10boiler121dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1116Cascade MCM10boiler121dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1117Cascade MCM10boiler121dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1118Cascade MCM10boiler121dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1119Cascade MCM10boiler121dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1120Cascade MCM10boiler121dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1121Cascade MCM10boiler121dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
1122Cascade MCM10boiler121dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1123Cascade MCM10boiler121dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1124Cascade MCM10boiler121dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1125Cascade MCM10boiler121dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1126Cascade MCM10boiler121nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1127Cascade MCM10boiler121nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1128Cascade MCM10boiler121nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1129Cascade MCM10boiler121dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1130Prolineboiler122resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1131Prolineboiler122heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1132Prolineboiler122heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1133Prolineboiler122tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1134Prolineboiler122selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1135Prolineboiler122heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1136Prolineboiler122outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1137Prolineboiler122curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1138Prolineboiler122rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1139Prolineboiler122switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1140Prolineboiler122syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1141Prolineboiler122boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1142Prolineboiler122headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1143Prolineboiler122exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1144Prolineboiler122burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1145Prolineboiler122burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1146Prolineboiler122flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1147Prolineboiler122fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1148Prolineboiler122ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1149Prolineboiler122oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1150Prolineboiler122burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1151Prolineboiler122burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1152Prolineboiler122burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1153Prolineboiler122absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1154Prolineboiler122heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1155Prolineboiler122boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1156Prolineboiler122boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1157Prolineboiler122boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1158Prolineboiler122boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1159Prolineboiler122curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1160Prolineboiler122curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1161Prolineboiler122curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1162Prolineboiler122summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1163Prolineboiler122nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1164Prolineboiler122nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1165Prolineboiler122heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1166Prolineboiler122heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1167Prolineboiler122heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1168Prolineboiler122pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1169Prolineboiler122pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1170Prolineboiler122pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1171Prolineboiler122pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1172Prolineboiler122pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1173Prolineboiler122pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1174Prolineboiler122selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1175Prolineboiler122curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1176Prolineboiler122burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1177Prolineboiler122burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1178Prolineboiler122burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1179Prolineboiler122heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1180Prolineboiler122heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1181Prolineboiler122ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1182Prolineboiler122lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1183Prolineboiler122servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1184Prolineboiler122servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1185Prolineboiler122maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1186Prolineboiler122maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1187Prolineboiler122maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1188Prolineboiler122maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1189Prolineboiler122emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1190Prolineboiler122emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1191Prolineboiler122pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1192Prolineboiler122pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1193Prolineboiler122pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1194Prolineboiler122pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1195Prolineboiler122meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1196Prolineboiler122dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1197Prolineboiler122gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1198Prolineboiler122dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1199Prolineboiler122nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1200Prolineboiler122dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1201Prolineboiler122dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1202Prolineboiler122dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1203Prolineboiler122dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1204Prolineboiler122dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1205Prolineboiler122dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1206Prolineboiler122dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1207Prolineboiler122dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1208Prolineboiler122dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1209Prolineboiler122dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1210Prolineboiler122dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1211Prolineboiler122dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1212Prolineboiler122dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1213Prolineboiler122dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1214Prolineboiler122dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1215Prolineboiler122dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1216Prolineboiler122dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1217Prolineboiler122dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1218Prolineboiler122dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1219Prolineboiler122dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1220Prolineboiler122dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1221Prolineboiler122dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1222Prolineboiler122dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1223Prolineboiler122dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1224Prolineboiler122dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1225Prolineboiler122dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1226Prolineboiler122dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1227Prolineboiler122dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1228Prolineboiler122dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1229Prolineboiler122dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1230Prolineboiler122dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1231Prolineboiler122dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1232Prolineboiler122dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1233Prolineboiler122dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1234Prolineboiler122dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1235Prolineboiler122dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1236Prolineboiler122dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
1237Prolineboiler122dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1238Prolineboiler122dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1239Prolineboiler122dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1240Prolineboiler122dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1241Prolineboiler122nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1242Prolineboiler122nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1243Prolineboiler122nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1244Prolineboiler122dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1245GB*72, Trendline, Cerapur, Greenstar Siboiler123resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1246GB*72, Trendline, Cerapur, Greenstar Siboiler123heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1247GB*72, Trendline, Cerapur, Greenstar Siboiler123heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1248GB*72, Trendline, Cerapur, Greenstar Siboiler123tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1249GB*72, Trendline, Cerapur, Greenstar Siboiler123selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1250GB*72, Trendline, Cerapur, Greenstar Siboiler123heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1251GB*72, Trendline, Cerapur, Greenstar Siboiler123outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1252GB*72, Trendline, Cerapur, Greenstar Siboiler123curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1253GB*72, Trendline, Cerapur, Greenstar Siboiler123rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1254GB*72, Trendline, Cerapur, Greenstar Siboiler123switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1255GB*72, Trendline, Cerapur, Greenstar Siboiler123syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1256GB*72, Trendline, Cerapur, Greenstar Siboiler123boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1257GB*72, Trendline, Cerapur, Greenstar Siboiler123headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1258GB*72, Trendline, Cerapur, Greenstar Siboiler123exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1259GB*72, Trendline, Cerapur, Greenstar Siboiler123burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1260GB*72, Trendline, Cerapur, Greenstar Siboiler123burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1261GB*72, Trendline, Cerapur, Greenstar Siboiler123flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1262GB*72, Trendline, Cerapur, Greenstar Siboiler123fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1263GB*72, Trendline, Cerapur, Greenstar Siboiler123ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1264GB*72, Trendline, Cerapur, Greenstar Siboiler123oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1265GB*72, Trendline, Cerapur, Greenstar Siboiler123burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1266GB*72, Trendline, Cerapur, Greenstar Siboiler123burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1267GB*72, Trendline, Cerapur, Greenstar Siboiler123burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1268GB*72, Trendline, Cerapur, Greenstar Siboiler123absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1269GB*72, Trendline, Cerapur, Greenstar Siboiler123heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1270GB*72, Trendline, Cerapur, Greenstar Siboiler123boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1271GB*72, Trendline, Cerapur, Greenstar Siboiler123boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1272GB*72, Trendline, Cerapur, Greenstar Siboiler123boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1273GB*72, Trendline, Cerapur, Greenstar Siboiler123boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1274GB*72, Trendline, Cerapur, Greenstar Siboiler123curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1275GB*72, Trendline, Cerapur, Greenstar Siboiler123curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1276GB*72, Trendline, Cerapur, Greenstar Siboiler123curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1277GB*72, Trendline, Cerapur, Greenstar Siboiler123summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1278GB*72, Trendline, Cerapur, Greenstar Siboiler123nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1279GB*72, Trendline, Cerapur, Greenstar Siboiler123nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1280GB*72, Trendline, Cerapur, Greenstar Siboiler123heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1281GB*72, Trendline, Cerapur, Greenstar Siboiler123heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1282GB*72, Trendline, Cerapur, Greenstar Siboiler123heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1283GB*72, Trendline, Cerapur, Greenstar Siboiler123pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1284GB*72, Trendline, Cerapur, Greenstar Siboiler123pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1285GB*72, Trendline, Cerapur, Greenstar Siboiler123pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1286GB*72, Trendline, Cerapur, Greenstar Siboiler123pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1287GB*72, Trendline, Cerapur, Greenstar Siboiler123pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1288GB*72, Trendline, Cerapur, Greenstar Siboiler123pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1289GB*72, Trendline, Cerapur, Greenstar Siboiler123selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1290GB*72, Trendline, Cerapur, Greenstar Siboiler123curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1291GB*72, Trendline, Cerapur, Greenstar Siboiler123burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1292GB*72, Trendline, Cerapur, Greenstar Siboiler123burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1293GB*72, Trendline, Cerapur, Greenstar Siboiler123burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1294GB*72, Trendline, Cerapur, Greenstar Siboiler123heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1295GB*72, Trendline, Cerapur, Greenstar Siboiler123heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1296GB*72, Trendline, Cerapur, Greenstar Siboiler123ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1297GB*72, Trendline, Cerapur, Greenstar Siboiler123lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1298GB*72, Trendline, Cerapur, Greenstar Siboiler123servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1299GB*72, Trendline, Cerapur, Greenstar Siboiler123servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1300GB*72, Trendline, Cerapur, Greenstar Siboiler123maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1301GB*72, Trendline, Cerapur, Greenstar Siboiler123maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1302GB*72, Trendline, Cerapur, Greenstar Siboiler123maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1303GB*72, Trendline, Cerapur, Greenstar Siboiler123maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1304GB*72, Trendline, Cerapur, Greenstar Siboiler123emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1305GB*72, Trendline, Cerapur, Greenstar Siboiler123emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1306GB*72, Trendline, Cerapur, Greenstar Siboiler123pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1307GB*72, Trendline, Cerapur, Greenstar Siboiler123pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1308GB*72, Trendline, Cerapur, Greenstar Siboiler123pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1309GB*72, Trendline, Cerapur, Greenstar Siboiler123pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1310GB*72, Trendline, Cerapur, Greenstar Siboiler123meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1311GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1312GB*72, Trendline, Cerapur, Greenstar Siboiler123gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1313GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1314GB*72, Trendline, Cerapur, Greenstar Siboiler123nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1315GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1316GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1317GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1318GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1319GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1320GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1321GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1322GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1323GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1324GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1325GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1326GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1327GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1328GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1329GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1330GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1331GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1332GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1333GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1334GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1335GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1336GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1337GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1338GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1339GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1340GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1341GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1342GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1343GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1344GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1345GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1346GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1347GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1348GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1349GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1350GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1351GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
1352GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1353GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1354GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1355GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1356GB*72, Trendline, Cerapur, Greenstar Siboiler123nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1357GB*72, Trendline, Cerapur, Greenstar Siboiler123nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1358GB*72, Trendline, Cerapur, Greenstar Siboiler123nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1359GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1360GB212boiler131resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1361GB212boiler131heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1362GB212boiler131heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1363GB212boiler131tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1364GB212boiler131selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1365GB212boiler131heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1366GB212boiler131outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1367GB212boiler131curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1368GB212boiler131rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1369GB212boiler131switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1370GB212boiler131syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1371GB212boiler131boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1372GB212boiler131headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1373GB212boiler131exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1374GB212boiler131burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1375GB212boiler131burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1376GB212boiler131flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1377GB212boiler131fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1378GB212boiler131ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1379GB212boiler131oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1380GB212boiler131burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1381GB212boiler131burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1382GB212boiler131burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1383GB212boiler131absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1384GB212boiler131heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1385GB212boiler131boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1386GB212boiler131boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1387GB212boiler131boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1388GB212boiler131boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1389GB212boiler131curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1390GB212boiler131curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1391GB212boiler131curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1392GB212boiler131summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1393GB212boiler131nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1394GB212boiler131nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1395GB212boiler131heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1396GB212boiler131heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1397GB212boiler131heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1398GB212boiler131pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1399GB212boiler131pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1400GB212boiler131pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1401GB212boiler131pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1402GB212boiler131pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1403GB212boiler131pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1404GB212boiler131selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1405GB212boiler131curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1406GB212boiler131burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1407GB212boiler131burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1408GB212boiler131burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1409GB212boiler131heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1410GB212boiler131heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1411GB212boiler131ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1412GB212boiler131lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1413GB212boiler131servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1414GB212boiler131servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1415GB212boiler131maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1416GB212boiler131maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1417GB212boiler131maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1418GB212boiler131maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1419GB212boiler131emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1420GB212boiler131emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1421GB212boiler131pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1422GB212boiler131pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1423GB212boiler131pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1424GB212boiler131pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1425GB212boiler131meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1426GB212boiler131dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1427GB212boiler131gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1428GB212boiler131dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1429GB212boiler131nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1430GB212boiler131dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1431GB212boiler131dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1432GB212boiler131dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1433GB212boiler131dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1434GB212boiler131dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1435GB212boiler131dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1436GB212boiler131dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1437GB212boiler131dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1438GB212boiler131dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1439GB212boiler131dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1440GB212boiler131dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1441GB212boiler131dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1442GB212boiler131dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1443GB212boiler131dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1444GB212boiler131dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1445GB212boiler131dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1446GB212boiler131dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1447GB212boiler131dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1448GB212boiler131dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1449GB212boiler131dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1450GB212boiler131dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1451GB212boiler131dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1452GB212boiler131dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1453GB212boiler131dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1454GB212boiler131dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1455GB212boiler131dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1456GB212boiler131dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1457GB212boiler131dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1458GB212boiler131dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1459GB212boiler131dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1460GB212boiler131dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1461GB212boiler131dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1462GB212boiler131dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1463GB212boiler131dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1464GB212boiler131dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1465GB212boiler131dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1466GB212boiler131dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
1467GB212boiler131dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1468GB212boiler131dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1469GB212boiler131dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1470GB212boiler131dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1471GB212boiler131nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1472GB212boiler131nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1473GB212boiler131nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1474GB212boiler131dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1475GC7000Fboiler132resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1476GC7000Fboiler132heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1477GC7000Fboiler132heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1478GC7000Fboiler132tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1479GC7000Fboiler132selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1480GC7000Fboiler132heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1481GC7000Fboiler132outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1482GC7000Fboiler132curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1483GC7000Fboiler132rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1484GC7000Fboiler132switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1485GC7000Fboiler132syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1486GC7000Fboiler132boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1487GC7000Fboiler132headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1488GC7000Fboiler132exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1489GC7000Fboiler132burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1490GC7000Fboiler132burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1491GC7000Fboiler132flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1492GC7000Fboiler132fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1493GC7000Fboiler132ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1494GC7000Fboiler132oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1495GC7000Fboiler132burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1496GC7000Fboiler132burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1497GC7000Fboiler132burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1498GC7000Fboiler132absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1499GC7000Fboiler132heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1500GC7000Fboiler132boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1501GC7000Fboiler132boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1502GC7000Fboiler132boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1503GC7000Fboiler132boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1504GC7000Fboiler132curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1505GC7000Fboiler132curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1506GC7000Fboiler132curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1507GC7000Fboiler132summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1508GC7000Fboiler132nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1509GC7000Fboiler132nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1510GC7000Fboiler132heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1511GC7000Fboiler132heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1512GC7000Fboiler132heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1513GC7000Fboiler132pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1514GC7000Fboiler132pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1515GC7000Fboiler132pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1516GC7000Fboiler132pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1517GC7000Fboiler132pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1518GC7000Fboiler132pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1519GC7000Fboiler132selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1520GC7000Fboiler132curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1521GC7000Fboiler132burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1522GC7000Fboiler132burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1523GC7000Fboiler132burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1524GC7000Fboiler132heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1525GC7000Fboiler132heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1526GC7000Fboiler132ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1527GC7000Fboiler132lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1528GC7000Fboiler132servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1529GC7000Fboiler132servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1530GC7000Fboiler132maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1531GC7000Fboiler132maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1532GC7000Fboiler132maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1533GC7000Fboiler132maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1534GC7000Fboiler132emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1535GC7000Fboiler132emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1536GC7000Fboiler132pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1537GC7000Fboiler132pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1538GC7000Fboiler132pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1539GC7000Fboiler132pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1540GC7000Fboiler132meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1541GC7000Fboiler132dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1542GC7000Fboiler132gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1543GC7000Fboiler132dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1544GC7000Fboiler132nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1545GC7000Fboiler132dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1546GC7000Fboiler132dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1547GC7000Fboiler132dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1548GC7000Fboiler132dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1549GC7000Fboiler132dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1550GC7000Fboiler132dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1551GC7000Fboiler132dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1552GC7000Fboiler132dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1553GC7000Fboiler132dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1554GC7000Fboiler132dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1555GC7000Fboiler132dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1556GC7000Fboiler132dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1557GC7000Fboiler132dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1558GC7000Fboiler132dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1559GC7000Fboiler132dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1560GC7000Fboiler132dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1561GC7000Fboiler132dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1562GC7000Fboiler132dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1563GC7000Fboiler132dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1564GC7000Fboiler132dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1565GC7000Fboiler132dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1566GC7000Fboiler132dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1567GC7000Fboiler132dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1568GC7000Fboiler132dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1569GC7000Fboiler132dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1570GC7000Fboiler132dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1571GC7000Fboiler132dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1572GC7000Fboiler132dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1573GC7000Fboiler132dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1574GC7000Fboiler132dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1575GC7000Fboiler132dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1576GC7000Fboiler132dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1577GC7000Fboiler132dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1578GC7000Fboiler132dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1579GC7000Fboiler132dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1580GC7000Fboiler132dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1581GC7000Fboiler132dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
1582GC7000Fboiler132dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1583GC7000Fboiler132dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1584GC7000Fboiler132dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1585GC7000Fboiler132dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1586GC7000Fboiler132nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1587GC7000Fboiler132nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1588GC7000Fboiler132nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1589GC7000Fboiler132dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1590Logano GB125/KB195i, Logamatic MC110boiler133resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1591Logano GB125/KB195i, Logamatic MC110boiler133heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1592Logano GB125/KB195i, Logamatic MC110boiler133heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1593Logano GB125/KB195i, Logamatic MC110boiler133tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1594Logano GB125/KB195i, Logamatic MC110boiler133selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1595Logano GB125/KB195i, Logamatic MC110boiler133heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1596Logano GB125/KB195i, Logamatic MC110boiler133outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1597Logano GB125/KB195i, Logamatic MC110boiler133curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1598Logano GB125/KB195i, Logamatic MC110boiler133rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1599Logano GB125/KB195i, Logamatic MC110boiler133switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1600Logano GB125/KB195i, Logamatic MC110boiler133syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1601Logano GB125/KB195i, Logamatic MC110boiler133boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1602Logano GB125/KB195i, Logamatic MC110boiler133headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1603Logano GB125/KB195i, Logamatic MC110boiler133exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1604Logano GB125/KB195i, Logamatic MC110boiler133burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1605Logano GB125/KB195i, Logamatic MC110boiler133burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1606Logano GB125/KB195i, Logamatic MC110boiler133flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1607Logano GB125/KB195i, Logamatic MC110boiler133fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1608Logano GB125/KB195i, Logamatic MC110boiler133ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1609Logano GB125/KB195i, Logamatic MC110boiler133oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1610Logano GB125/KB195i, Logamatic MC110boiler133burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1611Logano GB125/KB195i, Logamatic MC110boiler133burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1612Logano GB125/KB195i, Logamatic MC110boiler133burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1613Logano GB125/KB195i, Logamatic MC110boiler133absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1614Logano GB125/KB195i, Logamatic MC110boiler133heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1615Logano GB125/KB195i, Logamatic MC110boiler133boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1616Logano GB125/KB195i, Logamatic MC110boiler133boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1617Logano GB125/KB195i, Logamatic MC110boiler133boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1618Logano GB125/KB195i, Logamatic MC110boiler133boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1619Logano GB125/KB195i, Logamatic MC110boiler133curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1620Logano GB125/KB195i, Logamatic MC110boiler133curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1621Logano GB125/KB195i, Logamatic MC110boiler133curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1622Logano GB125/KB195i, Logamatic MC110boiler133summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1623Logano GB125/KB195i, Logamatic MC110boiler133nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1624Logano GB125/KB195i, Logamatic MC110boiler133nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1625Logano GB125/KB195i, Logamatic MC110boiler133heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1626Logano GB125/KB195i, Logamatic MC110boiler133heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1627Logano GB125/KB195i, Logamatic MC110boiler133heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1628Logano GB125/KB195i, Logamatic MC110boiler133pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1629Logano GB125/KB195i, Logamatic MC110boiler133pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1630Logano GB125/KB195i, Logamatic MC110boiler133pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1631Logano GB125/KB195i, Logamatic MC110boiler133pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1632Logano GB125/KB195i, Logamatic MC110boiler133pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1633Logano GB125/KB195i, Logamatic MC110boiler133pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1634Logano GB125/KB195i, Logamatic MC110boiler133selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1635Logano GB125/KB195i, Logamatic MC110boiler133curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1636Logano GB125/KB195i, Logamatic MC110boiler133burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1637Logano GB125/KB195i, Logamatic MC110boiler133burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1638Logano GB125/KB195i, Logamatic MC110boiler133burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1639Logano GB125/KB195i, Logamatic MC110boiler133heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1640Logano GB125/KB195i, Logamatic MC110boiler133heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1641Logano GB125/KB195i, Logamatic MC110boiler133ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1642Logano GB125/KB195i, Logamatic MC110boiler133lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1643Logano GB125/KB195i, Logamatic MC110boiler133servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1644Logano GB125/KB195i, Logamatic MC110boiler133servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1645Logano GB125/KB195i, Logamatic MC110boiler133maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1646Logano GB125/KB195i, Logamatic MC110boiler133maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1647Logano GB125/KB195i, Logamatic MC110boiler133maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1648Logano GB125/KB195i, Logamatic MC110boiler133maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1649Logano GB125/KB195i, Logamatic MC110boiler133emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1650Logano GB125/KB195i, Logamatic MC110boiler133emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1651Logano GB125/KB195i, Logamatic MC110boiler133pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1652Logano GB125/KB195i, Logamatic MC110boiler133pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1653Logano GB125/KB195i, Logamatic MC110boiler133pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1654Logano GB125/KB195i, Logamatic MC110boiler133pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1655Logano GB125/KB195i, Logamatic MC110boiler133meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1656Logano GB125/KB195i, Logamatic MC110boiler133dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1657Logano GB125/KB195i, Logamatic MC110boiler133gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1658Logano GB125/KB195i, Logamatic MC110boiler133dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1659Logano GB125/KB195i, Logamatic MC110boiler133nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1660Logano GB125/KB195i, Logamatic MC110boiler133dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1661Logano GB125/KB195i, Logamatic MC110boiler133dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1662Logano GB125/KB195i, Logamatic MC110boiler133dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1663Logano GB125/KB195i, Logamatic MC110boiler133dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1664Logano GB125/KB195i, Logamatic MC110boiler133dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1665Logano GB125/KB195i, Logamatic MC110boiler133dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1666Logano GB125/KB195i, Logamatic MC110boiler133dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1667Logano GB125/KB195i, Logamatic MC110boiler133dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1668Logano GB125/KB195i, Logamatic MC110boiler133dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1669Logano GB125/KB195i, Logamatic MC110boiler133dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1670Logano GB125/KB195i, Logamatic MC110boiler133dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1671Logano GB125/KB195i, Logamatic MC110boiler133dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1672Logano GB125/KB195i, Logamatic MC110boiler133dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1673Logano GB125/KB195i, Logamatic MC110boiler133dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1674Logano GB125/KB195i, Logamatic MC110boiler133dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1675Logano GB125/KB195i, Logamatic MC110boiler133dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1676Logano GB125/KB195i, Logamatic MC110boiler133dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1677Logano GB125/KB195i, Logamatic MC110boiler133dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1678Logano GB125/KB195i, Logamatic MC110boiler133dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1679Logano GB125/KB195i, Logamatic MC110boiler133dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1680Logano GB125/KB195i, Logamatic MC110boiler133dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1681Logano GB125/KB195i, Logamatic MC110boiler133dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1682Logano GB125/KB195i, Logamatic MC110boiler133dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1683Logano GB125/KB195i, Logamatic MC110boiler133dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1684Logano GB125/KB195i, Logamatic MC110boiler133dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1685Logano GB125/KB195i, Logamatic MC110boiler133dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1686Logano GB125/KB195i, Logamatic MC110boiler133dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1687Logano GB125/KB195i, Logamatic MC110boiler133dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1688Logano GB125/KB195i, Logamatic MC110boiler133dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1689Logano GB125/KB195i, Logamatic MC110boiler133dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1690Logano GB125/KB195i, Logamatic MC110boiler133dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1691Logano GB125/KB195i, Logamatic MC110boiler133dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1692Logano GB125/KB195i, Logamatic MC110boiler133dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1693Logano GB125/KB195i, Logamatic MC110boiler133dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1694Logano GB125/KB195i, Logamatic MC110boiler133dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1695Logano GB125/KB195i, Logamatic MC110boiler133dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1696Logano GB125/KB195i, Logamatic MC110boiler133dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
1697Logano GB125/KB195i, Logamatic MC110boiler133dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1698Logano GB125/KB195i, Logamatic MC110boiler133dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1699Logano GB125/KB195i, Logamatic MC110boiler133dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1700Logano GB125/KB195i, Logamatic MC110boiler133dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1701Logano GB125/KB195i, Logamatic MC110boiler133nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1702Logano GB125/KB195i, Logamatic MC110boiler133nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1703Logano GB125/KB195i, Logamatic MC110boiler133nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1704Logano GB125/KB195i, Logamatic MC110boiler133dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1705Greenstar 30Ri Compactboiler154resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1706Greenstar 30Ri Compactboiler154heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1707Greenstar 30Ri Compactboiler154heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1708Greenstar 30Ri Compactboiler154tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1709Greenstar 30Ri Compactboiler154selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1710Greenstar 30Ri Compactboiler154heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1711Greenstar 30Ri Compactboiler154outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1712Greenstar 30Ri Compactboiler154curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1713Greenstar 30Ri Compactboiler154rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1714Greenstar 30Ri Compactboiler154switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1715Greenstar 30Ri Compactboiler154syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1716Greenstar 30Ri Compactboiler154boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1717Greenstar 30Ri Compactboiler154headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1718Greenstar 30Ri Compactboiler154exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1719Greenstar 30Ri Compactboiler154burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1720Greenstar 30Ri Compactboiler154burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1721Greenstar 30Ri Compactboiler154flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1722Greenstar 30Ri Compactboiler154fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1723Greenstar 30Ri Compactboiler154ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1724Greenstar 30Ri Compactboiler154oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1725Greenstar 30Ri Compactboiler154burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1726Greenstar 30Ri Compactboiler154burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1727Greenstar 30Ri Compactboiler154burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1728Greenstar 30Ri Compactboiler154absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1729Greenstar 30Ri Compactboiler154heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1730Greenstar 30Ri Compactboiler154boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1731Greenstar 30Ri Compactboiler154boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1732Greenstar 30Ri Compactboiler154boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1733Greenstar 30Ri Compactboiler154boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1734Greenstar 30Ri Compactboiler154curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1735Greenstar 30Ri Compactboiler154curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1736Greenstar 30Ri Compactboiler154curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1737Greenstar 30Ri Compactboiler154summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1738Greenstar 30Ri Compactboiler154nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1739Greenstar 30Ri Compactboiler154nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1740Greenstar 30Ri Compactboiler154heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1741Greenstar 30Ri Compactboiler154heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1742Greenstar 30Ri Compactboiler154heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1743Greenstar 30Ri Compactboiler154pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1744Greenstar 30Ri Compactboiler154pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1745Greenstar 30Ri Compactboiler154pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1746Greenstar 30Ri Compactboiler154pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1747Greenstar 30Ri Compactboiler154pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1748Greenstar 30Ri Compactboiler154pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1749Greenstar 30Ri Compactboiler154selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1750Greenstar 30Ri Compactboiler154curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1751Greenstar 30Ri Compactboiler154burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1752Greenstar 30Ri Compactboiler154burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1753Greenstar 30Ri Compactboiler154burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1754Greenstar 30Ri Compactboiler154heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1755Greenstar 30Ri Compactboiler154heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1756Greenstar 30Ri Compactboiler154ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1757Greenstar 30Ri Compactboiler154lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1758Greenstar 30Ri Compactboiler154servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1759Greenstar 30Ri Compactboiler154servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1760Greenstar 30Ri Compactboiler154maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1761Greenstar 30Ri Compactboiler154maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1762Greenstar 30Ri Compactboiler154maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1763Greenstar 30Ri Compactboiler154maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1764Greenstar 30Ri Compactboiler154emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1765Greenstar 30Ri Compactboiler154emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1766Greenstar 30Ri Compactboiler154pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1767Greenstar 30Ri Compactboiler154pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1768Greenstar 30Ri Compactboiler154pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1769Greenstar 30Ri Compactboiler154pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1770Greenstar 30Ri Compactboiler154meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1771Greenstar 30Ri Compactboiler154dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1772Greenstar 30Ri Compactboiler154gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1773Greenstar 30Ri Compactboiler154dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1774Greenstar 30Ri Compactboiler154nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1775Greenstar 30Ri Compactboiler154dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1776Greenstar 30Ri Compactboiler154dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1777Greenstar 30Ri Compactboiler154dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1778Greenstar 30Ri Compactboiler154dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1779Greenstar 30Ri Compactboiler154dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1780Greenstar 30Ri Compactboiler154dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1781Greenstar 30Ri Compactboiler154dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1782Greenstar 30Ri Compactboiler154dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1783Greenstar 30Ri Compactboiler154dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1784Greenstar 30Ri Compactboiler154dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1785Greenstar 30Ri Compactboiler154dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1786Greenstar 30Ri Compactboiler154dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1787Greenstar 30Ri Compactboiler154dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1788Greenstar 30Ri Compactboiler154dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1789Greenstar 30Ri Compactboiler154dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1790Greenstar 30Ri Compactboiler154dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1791Greenstar 30Ri Compactboiler154dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1792Greenstar 30Ri Compactboiler154dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1793Greenstar 30Ri Compactboiler154dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1794Greenstar 30Ri Compactboiler154dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1795Greenstar 30Ri Compactboiler154dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1796Greenstar 30Ri Compactboiler154dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1797Greenstar 30Ri Compactboiler154dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1798Greenstar 30Ri Compactboiler154dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1799Greenstar 30Ri Compactboiler154dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1800Greenstar 30Ri Compactboiler154dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1801Greenstar 30Ri Compactboiler154dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1802Greenstar 30Ri Compactboiler154dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1803Greenstar 30Ri Compactboiler154dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1804Greenstar 30Ri Compactboiler154dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1805Greenstar 30Ri Compactboiler154dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1806Greenstar 30Ri Compactboiler154dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1807Greenstar 30Ri Compactboiler154dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1808Greenstar 30Ri Compactboiler154dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1809Greenstar 30Ri Compactboiler154dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1810Greenstar 30Ri Compactboiler154dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1811Greenstar 30Ri Compactboiler154dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
1812Greenstar 30Ri Compactboiler154dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1813Greenstar 30Ri Compactboiler154dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1814Greenstar 30Ri Compactboiler154dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1815Greenstar 30Ri Compactboiler154dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1816Greenstar 30Ri Compactboiler154nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1817Greenstar 30Ri Compactboiler154nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1818Greenstar 30Ri Compactboiler154nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1819Greenstar 30Ri Compactboiler154dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1820Suprapur-oboiler155resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1821Suprapur-oboiler155heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1822Suprapur-oboiler155heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1823Suprapur-oboiler155tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1824Suprapur-oboiler155selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1825Suprapur-oboiler155heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1826Suprapur-oboiler155outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1827Suprapur-oboiler155curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1828Suprapur-oboiler155rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1829Suprapur-oboiler155switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1830Suprapur-oboiler155syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1831Suprapur-oboiler155boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1832Suprapur-oboiler155headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1833Suprapur-oboiler155exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1834Suprapur-oboiler155burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1835Suprapur-oboiler155burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1836Suprapur-oboiler155flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1837Suprapur-oboiler155fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1838Suprapur-oboiler155ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1839Suprapur-oboiler155oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1840Suprapur-oboiler155burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1841Suprapur-oboiler155burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1842Suprapur-oboiler155burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1843Suprapur-oboiler155absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1844Suprapur-oboiler155heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1845Suprapur-oboiler155boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1846Suprapur-oboiler155boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1847Suprapur-oboiler155boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1848Suprapur-oboiler155boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1849Suprapur-oboiler155curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1850Suprapur-oboiler155curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1851Suprapur-oboiler155curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1852Suprapur-oboiler155summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1853Suprapur-oboiler155nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1854Suprapur-oboiler155nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1855Suprapur-oboiler155heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1856Suprapur-oboiler155heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1857Suprapur-oboiler155heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1858Suprapur-oboiler155pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1859Suprapur-oboiler155pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1860Suprapur-oboiler155pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1861Suprapur-oboiler155pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1862Suprapur-oboiler155pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1863Suprapur-oboiler155pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1864Suprapur-oboiler155selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1865Suprapur-oboiler155curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1866Suprapur-oboiler155burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1867Suprapur-oboiler155burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1868Suprapur-oboiler155burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1869Suprapur-oboiler155heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1870Suprapur-oboiler155heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1871Suprapur-oboiler155ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1872Suprapur-oboiler155lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1873Suprapur-oboiler155servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1874Suprapur-oboiler155servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1875Suprapur-oboiler155maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1876Suprapur-oboiler155maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1877Suprapur-oboiler155maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1878Suprapur-oboiler155maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1879Suprapur-oboiler155emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1880Suprapur-oboiler155emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1881Suprapur-oboiler155pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1882Suprapur-oboiler155pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1883Suprapur-oboiler155pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1884Suprapur-oboiler155pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1885Suprapur-oboiler155meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1886Suprapur-oboiler155dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1887Suprapur-oboiler155gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1888Suprapur-oboiler155dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1889Suprapur-oboiler155nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1890Suprapur-oboiler155dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1891Suprapur-oboiler155dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1892Suprapur-oboiler155dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1893Suprapur-oboiler155dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1894Suprapur-oboiler155dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1895Suprapur-oboiler155dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1896Suprapur-oboiler155dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1897Suprapur-oboiler155dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1898Suprapur-oboiler155dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1899Suprapur-oboiler155dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1900Suprapur-oboiler155dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1901Suprapur-oboiler155dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1902Suprapur-oboiler155dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1903Suprapur-oboiler155dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1904Suprapur-oboiler155dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1905Suprapur-oboiler155dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1906Suprapur-oboiler155dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1907Suprapur-oboiler155dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1908Suprapur-oboiler155dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1909Suprapur-oboiler155dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1910Suprapur-oboiler155dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1911Suprapur-oboiler155dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1912Suprapur-oboiler155dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1913Suprapur-oboiler155dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1914Suprapur-oboiler155dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1915Suprapur-oboiler155dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1916Suprapur-oboiler155dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1917Suprapur-oboiler155dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1918Suprapur-oboiler155dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1919Suprapur-oboiler155dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1920Suprapur-oboiler155dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1921Suprapur-oboiler155dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1922Suprapur-oboiler155dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1923Suprapur-oboiler155dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1924Suprapur-oboiler155dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1925Suprapur-oboiler155dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1926Suprapur-oboiler155dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
1927Suprapur-oboiler155dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1928Suprapur-oboiler155dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1929Suprapur-oboiler155dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1930Suprapur-oboiler155dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1931Suprapur-oboiler155nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1932Suprapur-oboiler155nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1933Suprapur-oboiler155nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1934Suprapur-oboiler155dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1935Cerapur Aeroboiler167resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1936Cerapur Aeroboiler167heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1937Cerapur Aeroboiler167heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1938Cerapur Aeroboiler167tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1939Cerapur Aeroboiler167selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1940Cerapur Aeroboiler167heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1941Cerapur Aeroboiler167outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1942Cerapur Aeroboiler167curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1943Cerapur Aeroboiler167rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1944Cerapur Aeroboiler167switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1945Cerapur Aeroboiler167syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1946Cerapur Aeroboiler167boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1947Cerapur Aeroboiler167headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1948Cerapur Aeroboiler167exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1949Cerapur Aeroboiler167burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1950Cerapur Aeroboiler167burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1951Cerapur Aeroboiler167flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1952Cerapur Aeroboiler167fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1953Cerapur Aeroboiler167ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1954Cerapur Aeroboiler167oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1955Cerapur Aeroboiler167burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1956Cerapur Aeroboiler167burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1957Cerapur Aeroboiler167burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1958Cerapur Aeroboiler167absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1959Cerapur Aeroboiler167heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1960Cerapur Aeroboiler167boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1961Cerapur Aeroboiler167boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1962Cerapur Aeroboiler167boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1963Cerapur Aeroboiler167boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1964Cerapur Aeroboiler167curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1965Cerapur Aeroboiler167curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1966Cerapur Aeroboiler167curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1967Cerapur Aeroboiler167summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1968Cerapur Aeroboiler167nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1969Cerapur Aeroboiler167nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1970Cerapur Aeroboiler167heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1971Cerapur Aeroboiler167heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1972Cerapur Aeroboiler167heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1973Cerapur Aeroboiler167pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1974Cerapur Aeroboiler167pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1975Cerapur Aeroboiler167pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1976Cerapur Aeroboiler167pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1977Cerapur Aeroboiler167pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1978Cerapur Aeroboiler167pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1979Cerapur Aeroboiler167selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1980Cerapur Aeroboiler167curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1981Cerapur Aeroboiler167burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1982Cerapur Aeroboiler167burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1983Cerapur Aeroboiler167burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1984Cerapur Aeroboiler167heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1985Cerapur Aeroboiler167heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1986Cerapur Aeroboiler167ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1987Cerapur Aeroboiler167lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1988Cerapur Aeroboiler167servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1989Cerapur Aeroboiler167servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1990Cerapur Aeroboiler167maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1991Cerapur Aeroboiler167maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1992Cerapur Aeroboiler167maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1993Cerapur Aeroboiler167maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1994Cerapur Aeroboiler167emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1995Cerapur Aeroboiler167emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1996Cerapur Aeroboiler167pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1997Cerapur Aeroboiler167pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1998Cerapur Aeroboiler167pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1999Cerapur Aeroboiler167pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
2000Cerapur Aeroboiler167meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
2001Cerapur Aeroboiler167dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
2002Cerapur Aeroboiler167gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
2003Cerapur Aeroboiler167dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
2004Cerapur Aeroboiler167nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
2005Cerapur Aeroboiler167dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
2006Cerapur Aeroboiler167dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
2007Cerapur Aeroboiler167dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
2008Cerapur Aeroboiler167dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
2009Cerapur Aeroboiler167dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
2010Cerapur Aeroboiler167dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
2011Cerapur Aeroboiler167dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
2012Cerapur Aeroboiler167dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
2013Cerapur Aeroboiler167dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
2014Cerapur Aeroboiler167dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
2015Cerapur Aeroboiler167dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
2016Cerapur Aeroboiler167dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
2017Cerapur Aeroboiler167dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
2018Cerapur Aeroboiler167dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
2019Cerapur Aeroboiler167dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
2020Cerapur Aeroboiler167dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
2021Cerapur Aeroboiler167dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
2022Cerapur Aeroboiler167dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
2023Cerapur Aeroboiler167dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
2024Cerapur Aeroboiler167dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
2025Cerapur Aeroboiler167dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
2026Cerapur Aeroboiler167dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
2027Cerapur Aeroboiler167dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
2028Cerapur Aeroboiler167dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
2029Cerapur Aeroboiler167dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
2030Cerapur Aeroboiler167dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
2031Cerapur Aeroboiler167dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
2032Cerapur Aeroboiler167dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
2033Cerapur Aeroboiler167dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
2034Cerapur Aeroboiler167dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
2035Cerapur Aeroboiler167dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
2036Cerapur Aeroboiler167dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
2037Cerapur Aeroboiler167dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
2038Cerapur Aeroboiler167dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
2039Cerapur Aeroboiler167dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
2040Cerapur Aeroboiler167dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
2041Cerapur Aeroboiler167dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
2042Cerapur Aeroboiler167dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
2043Cerapur Aeroboiler167dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
2044Cerapur Aeroboiler167dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
2045Cerapur Aeroboiler167dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
2046Cerapur Aeroboiler167nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
2047Cerapur Aeroboiler167nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
2048Cerapur Aeroboiler167nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
2049Cerapur Aeroboiler167dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
2050Hybrid Heatpumpboiler168resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
2051Hybrid Heatpumpboiler168heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
2052Hybrid Heatpumpboiler168heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
2053Hybrid Heatpumpboiler168tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
2054Hybrid Heatpumpboiler168selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
2055Hybrid Heatpumpboiler168heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
2056Hybrid Heatpumpboiler168outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
2057Hybrid Heatpumpboiler168curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
2058Hybrid Heatpumpboiler168rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
2059Hybrid Heatpumpboiler168switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
2060Hybrid Heatpumpboiler168syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
2061Hybrid Heatpumpboiler168boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
2062Hybrid Heatpumpboiler168headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
2063Hybrid Heatpumpboiler168exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
2064Hybrid Heatpumpboiler168burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
2065Hybrid Heatpumpboiler168burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
2066Hybrid Heatpumpboiler168flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
2067Hybrid Heatpumpboiler168fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
2068Hybrid Heatpumpboiler168ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
2069Hybrid Heatpumpboiler168oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
2070Hybrid Heatpumpboiler168burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
2071Hybrid Heatpumpboiler168burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
2072Hybrid Heatpumpboiler168burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
2073Hybrid Heatpumpboiler168absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
2074Hybrid Heatpumpboiler168heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
2075Hybrid Heatpumpboiler168boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
2076Hybrid Heatpumpboiler168boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
2077Hybrid Heatpumpboiler168boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
2078Hybrid Heatpumpboiler168boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
2079Hybrid Heatpumpboiler168curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
2080Hybrid Heatpumpboiler168curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
2081Hybrid Heatpumpboiler168curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
2082Hybrid Heatpumpboiler168summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
2083Hybrid Heatpumpboiler168nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
2084Hybrid Heatpumpboiler168nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
2085Hybrid Heatpumpboiler168heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
2086Hybrid Heatpumpboiler168heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
2087Hybrid Heatpumpboiler168heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
2088Hybrid Heatpumpboiler168pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
2089Hybrid Heatpumpboiler168pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
2090Hybrid Heatpumpboiler168pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
2091Hybrid Heatpumpboiler168pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
2092Hybrid Heatpumpboiler168pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
2093Hybrid Heatpumpboiler168pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
2094Hybrid Heatpumpboiler168selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
2095Hybrid Heatpumpboiler168curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
2096Hybrid Heatpumpboiler168burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
2097Hybrid Heatpumpboiler168burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
2098Hybrid Heatpumpboiler168burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
2099Hybrid Heatpumpboiler168heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
2100Hybrid Heatpumpboiler168heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
2101Hybrid Heatpumpboiler168ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
2102Hybrid Heatpumpboiler168lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
2103Hybrid Heatpumpboiler168servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
2104Hybrid Heatpumpboiler168servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
2105Hybrid Heatpumpboiler168maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
2106Hybrid Heatpumpboiler168maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
2107Hybrid Heatpumpboiler168maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
2108Hybrid Heatpumpboiler168maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
2109Hybrid Heatpumpboiler168emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
2110Hybrid Heatpumpboiler168emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
2111Hybrid Heatpumpboiler168pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
2112Hybrid Heatpumpboiler168pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
2113Hybrid Heatpumpboiler168pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
2114Hybrid Heatpumpboiler168pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
2115Hybrid Heatpumpboiler168meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
2116Hybrid Heatpumpboiler168dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
2117Hybrid Heatpumpboiler168gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
2118Hybrid Heatpumpboiler168dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
2119Hybrid Heatpumpboiler168nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
2120Hybrid Heatpumpboiler168dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
2121Hybrid Heatpumpboiler168dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
2122Hybrid Heatpumpboiler168dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
2123Hybrid Heatpumpboiler168dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
2124Hybrid Heatpumpboiler168dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
2125Hybrid Heatpumpboiler168dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
2126Hybrid Heatpumpboiler168dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
2127Hybrid Heatpumpboiler168dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
2128Hybrid Heatpumpboiler168dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
2129Hybrid Heatpumpboiler168dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
2130Hybrid Heatpumpboiler168dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
2131Hybrid Heatpumpboiler168dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
2132Hybrid Heatpumpboiler168dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
2133Hybrid Heatpumpboiler168dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
2134Hybrid Heatpumpboiler168dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
2135Hybrid Heatpumpboiler168dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
2136Hybrid Heatpumpboiler168dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
2137Hybrid Heatpumpboiler168dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
2138Hybrid Heatpumpboiler168dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
2139Hybrid Heatpumpboiler168dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
2140Hybrid Heatpumpboiler168dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
2141Hybrid Heatpumpboiler168dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
2142Hybrid Heatpumpboiler168dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
2143Hybrid Heatpumpboiler168dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
2144Hybrid Heatpumpboiler168dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
2145Hybrid Heatpumpboiler168dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
2146Hybrid Heatpumpboiler168dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
2147Hybrid Heatpumpboiler168dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
2148Hybrid Heatpumpboiler168dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
2149Hybrid Heatpumpboiler168dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
2150Hybrid Heatpumpboiler168dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
2151Hybrid Heatpumpboiler168dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
2152Hybrid Heatpumpboiler168dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
2153Hybrid Heatpumpboiler168dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
2154Hybrid Heatpumpboiler168dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
2155Hybrid Heatpumpboiler168dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
2156Hybrid Heatpumpboiler168dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
2157Hybrid Heatpumpboiler168dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
2158Hybrid Heatpumpboiler168dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
2159Hybrid Heatpumpboiler168dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
2160Hybrid Heatpumpboiler168dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
2161Hybrid Heatpumpboiler168nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
2162Hybrid Heatpumpboiler168nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
2163Hybrid Heatpumpboiler168nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
2164Hybrid Heatpumpboiler168dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
2165Logano GB212boiler170resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
2166Logano GB212boiler170heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
2167Logano GB212boiler170heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
2168Logano GB212boiler170tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
2169Logano GB212boiler170selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
2170Logano GB212boiler170heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
2171Logano GB212boiler170outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
2172Logano GB212boiler170curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
2173Logano GB212boiler170rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
2174Logano GB212boiler170switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
2175Logano GB212boiler170syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
2176Logano GB212boiler170boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
2177Logano GB212boiler170headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
2178Logano GB212boiler170exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
2179Logano GB212boiler170burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
2180Logano GB212boiler170burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
2181Logano GB212boiler170flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
2182Logano GB212boiler170fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
2183Logano GB212boiler170ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
2184Logano GB212boiler170oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
2185Logano GB212boiler170burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
2186Logano GB212boiler170burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
2187Logano GB212boiler170burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
2188Logano GB212boiler170absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
2189Logano GB212boiler170heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
2190Logano GB212boiler170boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
2191Logano GB212boiler170boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
2192Logano GB212boiler170boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
2193Logano GB212boiler170boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
2194Logano GB212boiler170curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
2195Logano GB212boiler170curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
2196Logano GB212boiler170curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
2197Logano GB212boiler170summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
2198Logano GB212boiler170nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
2199Logano GB212boiler170nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
2200Logano GB212boiler170heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
2201Logano GB212boiler170heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
2202Logano GB212boiler170heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
2203Logano GB212boiler170pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
2204Logano GB212boiler170pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
2205Logano GB212boiler170pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
2206Logano GB212boiler170pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
2207Logano GB212boiler170pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
2208Logano GB212boiler170pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
2209Logano GB212boiler170selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
2210Logano GB212boiler170curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
2211Logano GB212boiler170burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
2212Logano GB212boiler170burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
2213Logano GB212boiler170burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
2214Logano GB212boiler170heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
2215Logano GB212boiler170heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
2216Logano GB212boiler170ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
2217Logano GB212boiler170lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
2218Logano GB212boiler170servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
2219Logano GB212boiler170servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
2220Logano GB212boiler170maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
2221Logano GB212boiler170maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
2222Logano GB212boiler170maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
2223Logano GB212boiler170maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
2224Logano GB212boiler170emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
2225Logano GB212boiler170emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
2226Logano GB212boiler170pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
2227Logano GB212boiler170pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
2228Logano GB212boiler170pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
2229Logano GB212boiler170pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
2230Logano GB212boiler170meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
2231Logano GB212boiler170dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
2232Logano GB212boiler170gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
2233Logano GB212boiler170dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
2234Logano GB212boiler170nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
2235Logano GB212boiler170dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
2236Logano GB212boiler170dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
2237Logano GB212boiler170dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
2238Logano GB212boiler170dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
2239Logano GB212boiler170dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
2240Logano GB212boiler170dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
2241Logano GB212boiler170dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
2242Logano GB212boiler170dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
2243Logano GB212boiler170dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
2244Logano GB212boiler170dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
2245Logano GB212boiler170dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
2246Logano GB212boiler170dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
2247Logano GB212boiler170dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
2248Logano GB212boiler170dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
2249Logano GB212boiler170dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
2250Logano GB212boiler170dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
2251Logano GB212boiler170dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
2252Logano GB212boiler170dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
2253Logano GB212boiler170dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
2254Logano GB212boiler170dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
2255Logano GB212boiler170dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
2256Logano GB212boiler170dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
2257Logano GB212boiler170dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
2258Logano GB212boiler170dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
2259Logano GB212boiler170dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
2260Logano GB212boiler170dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
2261Logano GB212boiler170dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
2262Logano GB212boiler170dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
2263Logano GB212boiler170dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
2264Logano GB212boiler170dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
2265Logano GB212boiler170dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
2266Logano GB212boiler170dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
2267Logano GB212boiler170dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
2268Logano GB212boiler170dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
2269Logano GB212boiler170dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
2270Logano GB212boiler170dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
2271Logano GB212boiler170dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
2272Logano GB212boiler170dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
2273Logano GB212boiler170dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
2274Logano GB212boiler170dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
2275Logano GB212boiler170dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
2276Logano GB212boiler170nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
2277Logano GB212boiler170nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
2278Logano GB212boiler170nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
2279Logano GB212boiler170dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
2280Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
2281Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
2282Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
2283Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
2284Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
2285Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
2286Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
2287Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
2288Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
2289Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
2290Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
2291Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
2292Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
2293Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
2294Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
2295Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
2296Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
2297Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
2298Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
2299Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
2300Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
2301Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
2302Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
2303Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
2304Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
2305Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
2306Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
2307Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
2308Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
2309Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
2310Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
2311Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
2312Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
2313Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
2314Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
2315Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
2316Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
2317Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
2318Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
2319Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
2320Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
2321Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
2322Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
2323Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
2324Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.nrgenergyuint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_energysensor.boiler_dhw_nrg591/10002
2325Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgheatenergy heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_heatingsensor.boiler_nrgheat501/100852
2326Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgcoolenergy coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_coolingsensor.boiler_nrgcool501/100872
2327Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172metertotalmeter totaluint24 (>=0<=167772)kWhfalsesensor.boiler_meter_totalsensor.boiler_metertotal501/100892
2328Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172metercompmeter compressoruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_compressorsensor.boiler_metercomp501/100912
2329Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172metereheatmeter e-heateruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_e-heatersensor.boiler_metereheat501/100932
2330Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172meterheatmeter heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/100952
2331Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172metercoolmeter coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_coolingsensor.boiler_metercool501/100972
2332Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.metermeteruint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/10022
2333Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172uptimetotalheatpump total uptimetime (>=0<=279620)minutesfalsesensor.boiler_heatpump_total_uptimesensor.boiler_uptimetotal501/60992
2334Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172uptimecontroltotal operating time heattime (>=0<=279620)minutesfalsesensor.boiler_total_operating_time_heatsensor.boiler_uptimecontrol501/601012
2335Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172uptimecompheatingoperating time compressor heatingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_heatingsensor.boiler_uptimecompheating501/601032
2336Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172uptimecompcoolingoperating time compressor coolingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_coolingsensor.boiler_uptimecompcooling501/601052
2337Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.uptimecompoperating time compressortime (>=0<=279620)minutesfalsesensor.boiler_dhw_operating_time_compressorsensor.boiler_dhw_uptimecomp591/6042
2338Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172uptimecomppooloperating time compressor pooltime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_poolsensor.boiler_uptimecomppool501/601072
2339Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172totalcompstartstotal compressor control startsuint24 (>=0<=16777214)falsesensor.boiler_total_compressor_control_startssensor.boiler_totalcompstarts5011092
2340Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatingstartsheating control startsuint24 (>=0<=16777214)falsesensor.boiler_heating_control_startssensor.boiler_heatingstarts5011112
2341Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172coolingstartscooling control startsuint24 (>=0<=16777214)falsesensor.boiler_cooling_control_startssensor.boiler_coolingstarts5011132
2342Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.startshpstarts hpuint24 (>=0<=16777214)falsesensor.boiler_dhw_starts_hpsensor.boiler_dhw_startshp59162
2343Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172poolstartspool control startsuint24 (>=0<=16777214)falsesensor.boiler_pool_control_startssensor.boiler_poolstarts5011152
2344Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgconstotaltotal energy consumptionuint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_consumptionsensor.boiler_nrgconstotal5011172
2345Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgconscomptotaltotal energy consumption compressoruint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_consumption_compressorsensor.boiler_nrgconscomptotal5011192
2346Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgconscompheatingenergy consumption compressor heatinguint24 (>=0<=16777214)kWhfalsesensor.boiler_energy_consumption_compressor_heatingsensor.boiler_nrgconscompheating5011212
2347Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.nrgconscompenergy consumption compressoruint24 (>=0<=16777214)kWhfalsesensor.boiler_dhw_energy_consumption_compressorsensor.boiler_dhw_nrgconscomp59182
2348Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgconscompcoolingenergy consumption compressor coolinguint24 (>=0<=16777214)kWhfalsesensor.boiler_energy_consumption_compressor_coolingsensor.boiler_nrgconscompcooling5011232
2349Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgconscomppoolenergy consumption compressor pooluint24 (>=0<=16777214)kWhfalsesensor.boiler_energy_consumption_compressor_poolsensor.boiler_nrgconscomppool5011252
2350Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxelecheatnrgconstotaltotal aux elec. heater energy consumptionuint24 (>=0<=16777214)kWhfalsesensor.boiler_total_aux_elec._heater_energy_consumptionsensor.boiler_auxelecheatnrgconstotal5011272
2351Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxelecheatnrgconsheatingaux elec. heater energy consumption heatinguint24 (>=0<=16777214)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_heatingsensor.boiler_auxelecheatnrgconsheating5011292
2352Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.auxelecheatnrgconsaux elec. heater energy consumptionuint24 (>=0<=16777214)kWhfalsesensor.boiler_dhw_aux_elec._heater_energy_consumptionsensor.boiler_dhw_auxelecheatnrgcons591102
2353Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxelecheatnrgconspoolaux elec. heater energy consumption pooluint24 (>=0<=16777214)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_poolsensor.boiler_auxelecheatnrgconspool5011312
2354Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgsupptotaltotal energy supplieduint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_suppliedsensor.boiler_nrgsupptotal5011332
2355Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgsuppheatingtotal energy supplied heatinguint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_supplied_heatingsensor.boiler_nrgsuppheating5011352
2356Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.nrgsupptotal energy warm supplieduint24 (>=0<=16777214)kWhfalsesensor.boiler_dhw_total_energy_warm_suppliedsensor.boiler_dhw_nrgsupp591122
2357Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgsuppcoolingtotal energy supplied coolinguint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_supplied_coolingsensor.boiler_nrgsuppcooling5011372
2358Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgsupppooltotal energy supplied pooluint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_supplied_poolsensor.boiler_nrgsupppool5011392
2359Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hppowercompressor power outputuint16 (>=0<=3199)kWfalsesensor.boiler_compressor_power_outputsensor.boiler_hppower501/101411
2360Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpmaxpowercompressor max poweruint8 (>=0<=100)%truenumber.boiler_compressor_max_powernumber.boiler_hpmaxpower5011421
2361Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pvmaxcomppv compressor max poweruint8 (>=0<=25)kWtruenumber.boiler_pv_compressor_max_powernumber.boiler_pvmaxcomp501/101431
2362Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172powerreductionpower reductionuint8 (>=30<=60)%truenumber.boiler_power_reductionnumber.boiler_powerreduction50101441
2363Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpsetdiffpressset differential pressureuint8 (>=150<=750)mbartruenumber.boiler_set_differential_pressurenumber.boiler_hpsetdiffpress50501451
2364Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpcomponhp compressorbooleanfalsebinary_sensor.boiler_hp_compressorbinary_sensor.boiler_hpcompon5011461
2365Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpactivitycompressor activityenum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm]falsesensor.boiler_compressor_activitysensor.boiler_hpactivity5011471
2366Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpbrinepumpspdbrine pump speeduint8 (>=0<=100)%falsesensor.boiler_brine_pump_speedsensor.boiler_hpbrinepumpspd5011481
2367Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpswitchvalveswitch valvebooleanfalsebinary_sensor.boiler_switch_valvebinary_sensor.boiler_hpswitchvalve5011491
2368Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpcompspdcompressor speeduint8 (>=0<=100)%falsesensor.boiler_compressor_speedsensor.boiler_hpcompspd5011501
2369Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpcircspdcirculation pump speeduint8 (>=0<=100)%falsesensor.boiler_circulation_pump_speedsensor.boiler_hpcircspd5011511
2370Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpbrineinbrine in/evaporatorint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_in/evaporatorsensor.boiler_hpbrinein501/101521
2371Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpbrineoutbrine out/condenserint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_out/condensersensor.boiler_hpbrineout501/101531
2372Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptc0heat carrier return (TC0)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_return_(TC0)sensor.boiler_hptc0501/101541
2373Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptc1heat carrier forward (TC1)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_forward_(TC1)sensor.boiler_hptc1501/101551
2374Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptc3condenser temperature (TC3)int16 (>=-3199<=3199)Cfalsesensor.boiler_condenser_temperature_(TC3)sensor.boiler_hptc3501/101561
2375Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptr1compressor temperature (TR1)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_temperature_(TR1)sensor.boiler_hptr1501/101571
2376Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptr3refrigerant temperature liquid side (condenser output) (TR3)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3)sensor.boiler_hptr3501/101581
2377Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptr4evaporator inlet temperature (TR4)int16 (>=-3199<=3199)Cfalsesensor.boiler_evaporator_inlet_temperature_(TR4)sensor.boiler_hptr4501/101591
2378Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptr5compressor inlet temperature (TR5)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_inlet_temperature_(TR5)sensor.boiler_hptr5501/101601
2379Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptr6compressor outlet temperature (TR6)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_outlet_temperature_(TR6)sensor.boiler_hptr6501/101611
2380Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptr7refrigerant temperature gas side (condenser input) (TR7)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7)sensor.boiler_hptr7501/101621
2381Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptl2air inlet temperature (TL2)int16 (>=-3199<=3199)Cfalsesensor.boiler_air_inlet_temperature_(TL2)sensor.boiler_hptl2501/101631
2382Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hppl1low pressure side temperature (PL1)int16 (>=-3199<=3199)Cfalsesensor.boiler_low_pressure_side_temperature_(PL1)sensor.boiler_hppl1501/101641
2383Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpph1high pressure side temperature (PH1)int16 (>=-3199<=3199)Cfalsesensor.boiler_high_pressure_side_temperature_(PH1)sensor.boiler_hpph1501/101651
2384Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpta4drain pan temp (TA4)int16 (>=-3199<=3199)Cfalsesensor.boiler_drain_pan_temp_(TA4)sensor.boiler_hpta4501/101661
2385Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptw1reservoir temp (TW1)int16 (>=-3199<=3199)Cfalsesensor.boiler_reservoir_temp_(TW1)sensor.boiler_hptw1501/101671
2386Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172poolsettemppool set temperatureuint8 (>=0<=127)Ctruenumber.boiler_pool_set_temperaturenumber.boiler_poolsettemp501/21681
2387Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hp4way4-way valve (VR4)enum [cooling & defrost\|heating & dhw]falsesensor.boiler_4-way_valve_(VR4)sensor.boiler_hp4way5011691
2388Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpin1input 1 statebooleanfalsebinary_sensor.boiler_input_1_statebinary_sensor.boiler_hpin15011701
2389Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpin1optinput 1 optionsstringtruesensor.boiler_input_1_optionssensor.boiler_hpin1opt5011718
2390Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpin2input 2 statebooleanfalsebinary_sensor.boiler_input_2_statebinary_sensor.boiler_hpin25011791
2391Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpin2optinput 2 optionsstringtruesensor.boiler_input_2_optionssensor.boiler_hpin2opt5011808
2392Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpin3input 3 statebooleanfalsebinary_sensor.boiler_input_3_statebinary_sensor.boiler_hpin35011881
2393Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpin3optinput 3 optionsstringtruesensor.boiler_input_3_optionssensor.boiler_hpin3opt5011898
2394Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpin4input 4 statebooleanfalsebinary_sensor.boiler_input_4_statebinary_sensor.boiler_hpin45011971
2395Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpin4optinput 4 optionsstringtruesensor.boiler_input_4_optionssensor.boiler_hpin4opt5011988
2396Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172maxheatcompheat limit compressorenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_compressorselect.boiler_maxheatcomp5012061
2397Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172maxheatheatheat limit heatingenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_heatingselect.boiler_maxheatheat5012071
2398Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.maxheatheat limitenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_dhw_heat_limitselect.boiler_dhw_maxheat591141
2399Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxheatersourceaux heater sourceenum [not installed\|electric heater\|exclusive\|parallel\|hybrid]trueselect.boiler_aux_heater_sourceselect.boiler_auxheatersource5012081
2400Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pvcoolingcooling only with PVbooleantrueswitch.boiler_cooling_only_with_PVswitch.boiler_pvcooling5012091
2401Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxheateronlyaux heater onlybooleantrueswitch.boiler_aux_heater_onlyswitch.boiler_auxheateronly5012101
2402Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxheateroffdisable aux heaterbooleantrueswitch.boiler_disable_aux_heaterswitch.boiler_auxheateroff5012111
2403Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxheaterstatusaux heater statusenum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm]falsesensor.boiler_aux_heater_statussensor.boiler_auxheaterstatus5012121
2404Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxheaterlevelaux heater leveluint8 (>=0<=100)%falsesensor.boiler_aux_heater_levelsensor.boiler_auxheaterlevel5012131
2405Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxheaterdelayaux heater on delayuint16 (>=10<=1000)K*mintruenumber.boiler_aux_heater_on_delaynumber.boiler_auxheaterdelay50102141
2406Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxmaxlimitaux heater max limituint8 (>=0<=10)Ktruenumber.boiler_aux_heater_max_limitnumber.boiler_auxmaxlimit501/102151
2407Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxlimitstartaux heater limit startuint8 (>=0<=10)Ktruenumber.boiler_aux_heater_limit_startnumber.boiler_auxlimitstart501/102161
2408Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxheatrmodeaux heater modeenum [eco\|comfort]trueselect.boiler_aux_heater_modeselect.boiler_auxheatrmode5012171
2409Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hphystheaton/off hyst heatuint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_heatnumber.boiler_hphystheat5052181
2410Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hphystcoolon/off hyst cooluint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_coolnumber.boiler_hphystcool5052191
2411Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hphystpoolon/off hyst pooluint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_poolnumber.boiler_hphystpool5052201
2412Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172silentmodesilent modeenum [off\|auto\|on]trueselect.boiler_silent_modeselect.boiler_silentmode5012211
2413Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172silentfromsilent mode fromuint8 (>=0<=3810)minutestruenumber.boiler_silent_mode_fromnumber.boiler_silentfrom50152221
2414Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172silenttosilent mode touint8 (>=0<=3810)minutestruenumber.boiler_silent_mode_tonumber.boiler_silentto50152231
2415Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172mintempsilentmin outside temp for silent modeint8 (>=-126<=126)Ctruenumber.boiler_min_outside_temp_for_silent_modenumber.boiler_mintempsilent5012241
2416Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172tempparmodeoutside temp parallel modeint8 (>=-126<=126)Ctruenumber.boiler_outside_temp_parallel_modenumber.boiler_tempparmode5012251
2417Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxheatmixaux heater mixing valveint8 (>=-100<=100)%falsesensor.boiler_aux_heater_mixing_valvesensor.boiler_auxheatmix5012261
2418Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172tempdiffheattemp diff TC3/TC0 heatuint8 (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_heatnumber.boiler_tempdiffheat501/102271
2419Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172tempdiffcooltemp diff TC3/TC0 cooluint8 (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_coolnumber.boiler_tempdiffcool501/102281
2420Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172vpcoolingvalve/pump coolingbooleantrueswitch.boiler_valve/pump_coolingswitch.boiler_vpcooling5012291
2421Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatcableheating cablebooleantrueswitch.boiler_heating_cableswitch.boiler_heatcable5012301
2422Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172vc0valveVC0 valvebooleantrueswitch.boiler_VC0_valveswitch.boiler_vc0valve5012311
2423Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172primepumpprimary heatpumpbooleantrueswitch.boiler_primary_heatpumpswitch.boiler_primepump5012321
2424Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172primepumpmodprimary heatpump modulationuint8 (>=0<=100)%truenumber.boiler_primary_heatpump_modulationnumber.boiler_primepumpmod5012331
2425Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hp3way3-way valvebooleantrueswitch.boiler_3-way_valveswitch.boiler_hp3way5012341
2426Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172elheatstep1el. heater step 1booleantrueswitch.boiler_el._heater_step_1switch.boiler_elheatstep15012351
2427Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172elheatstep2el. heater step 2booleantrueswitch.boiler_el._heater_step_2switch.boiler_elheatstep25012361
2428Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172elheatstep3el. heater step 3booleantrueswitch.boiler_el._heater_step_3switch.boiler_elheatstep35012371
2429Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpea0condensate reservoir heating (EA0)booleanfalsebinary_sensor.boiler_condensate_reservoir_heating_(EA0)binary_sensor.boiler_hpea05012381
2430Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hppumpmodeprimary heatpump modeenum [auto\|continuous]trueselect.boiler_primary_heatpump_modeselect.boiler_hppumpmode5012391
2431Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172fanfanuint8 (>=20<=100)%truenumber.boiler_fannumber.boiler_fan5012401
2432Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172shutdownshutdowncmd [off\|on]truesensor.boiler_shutdownsensor.boiler_shutdown5012411
2433Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpcurrpowercompressor current poweruint16 (>=0<=31999)Wfalsesensor.boiler_compressor_current_powersensor.boiler_hpcurrpower5012421
2434Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hppowerlimitpower limituint16 (>=0<=31999)Wtruenumber.boiler_power_limitnumber.boiler_hppowerlimit5012431
2435Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.alternatingopalternating operationbooleantrueswitch.boiler_dhw_alternating_operationswitch.boiler_dhw_alternatingop591151
2436Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.altopprioheatprioritise heating during dhwuint8 (>=20<=120)minutestruenumber.boiler_dhw_prioritise_heating_during_dhwnumber.boiler_dhw_altopprioheat591161
2437Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.altopprioprioritise dhw during heatinguint8 (>=30<=120)minutestruenumber.boiler_dhw_prioritise_dhw_during_heatingnumber.boiler_dhw_altopprio591171
2438Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.comfoffcomfort switch offuint8 (>=15<=65)Ctruenumber.boiler_dhw_comfort_switch_offnumber.boiler_dhw_comfoff591181
2439Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.ecooffeco switch offuint8 (>=15<=65)Ctruenumber.boiler_dhw_eco_switch_offnumber.boiler_dhw_ecooff591191
2440Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.ecoplusoffeco+ switch offuint8 (>=48<=63)Ctruenumber.boiler_dhw_eco+_switch_offnumber.boiler_dhw_ecoplusoff591201
2441Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.comfdiffcomfort diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_comfort_diffnumber.boiler_dhw_comfdiff591211
2442Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.ecodiffeco diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_eco_diffnumber.boiler_dhw_ecodiff591221
2443Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.ecoplusdiffeco+ diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_eco+_diffnumber.boiler_dhw_ecoplusdiff591231
2444Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.comfstopcomfort stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_comfort_stop_tempnumber.boiler_dhw_comfstop591241
2445Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.ecostopeco stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_eco_stop_tempnumber.boiler_dhw_ecostop591251
2446Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.ecoplusstopeco+ stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_eco+_stop_tempnumber.boiler_dhw_ecoplusstop591261
2447Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.hpcircpumpcirculation pump available during dhwbooleantrueswitch.boiler_dhw_circulation_pump_available_during_dhwswitch.boiler_dhw_hpcircpump591271
2448Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
2449Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
2450Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
2451Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
2452Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
2453Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
2454Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
2455Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
2456Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
2457Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
2458Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
2459Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
2460Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
2461Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
2462Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
2463Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
2464Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
2465Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
2466Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
2467Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
2468Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
2469Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
2470Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
2471Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
2472Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
2473Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
2474Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
2475Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
2476Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
2477Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
2478Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
2479Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
2480Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
2481Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
2482Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
2483Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
2484Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
2485Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
2486Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
2487Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
2488Geo 5xxboiler173resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
2489Geo 5xxboiler173heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
2490Geo 5xxboiler173heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
2491Geo 5xxboiler173tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
2492Geo 5xxboiler173selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
2493Geo 5xxboiler173heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
2494Geo 5xxboiler173outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
2495Geo 5xxboiler173curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
2496Geo 5xxboiler173rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
2497Geo 5xxboiler173switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
2498Geo 5xxboiler173syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
2499Geo 5xxboiler173boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
2500Geo 5xxboiler173headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
The file is too large to be shown. View Raw