Files
EMS-ESP32/dump_entities.csv
2023-09-16 09:39:57 +02:00

607 KiB

1device namedevice typeproduct idshortnamefullnametype [options...] \| (min/max)uomwriteablediscovery entityid v3.4discovery entityid
2BK13/BK15/Smartline/GB1x2boiler64resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
3BK13/BK15/Smartline/GB1x2boiler64heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
4BK13/BK15/Smartline/GB1x2boiler64tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
5BK13/BK15/Smartline/GB1x2boiler64selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
6BK13/BK15/Smartline/GB1x2boiler64heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
7BK13/BK15/Smartline/GB1x2boiler64outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
8BK13/BK15/Smartline/GB1x2boiler64curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
9BK13/BK15/Smartline/GB1x2boiler64rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
10BK13/BK15/Smartline/GB1x2boiler64switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
11BK13/BK15/Smartline/GB1x2boiler64syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
12BK13/BK15/Smartline/GB1x2boiler64boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
13BK13/BK15/Smartline/GB1x2boiler64exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
14BK13/BK15/Smartline/GB1x2boiler64burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
15BK13/BK15/Smartline/GB1x2boiler64burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
16BK13/BK15/Smartline/GB1x2boiler64flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
17BK13/BK15/Smartline/GB1x2boiler64heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
18BK13/BK15/Smartline/GB1x2boiler64fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
19BK13/BK15/Smartline/GB1x2boiler64ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
20BK13/BK15/Smartline/GB1x2boiler64oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
21BK13/BK15/Smartline/GB1x2boiler64heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
22BK13/BK15/Smartline/GB1x2boiler64heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
23BK13/BK15/Smartline/GB1x2boiler64pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
24BK13/BK15/Smartline/GB1x2boiler64pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
25BK13/BK15/Smartline/GB1x2boiler64pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
26BK13/BK15/Smartline/GB1x2boiler64pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
27BK13/BK15/Smartline/GB1x2boiler64burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
28BK13/BK15/Smartline/GB1x2boiler64burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
29BK13/BK15/Smartline/GB1x2boiler64burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
30BK13/BK15/Smartline/GB1x2boiler64boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
31BK13/BK15/Smartline/GB1x2boiler64boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
32BK13/BK15/Smartline/GB1x2boiler64boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
33BK13/BK15/Smartline/GB1x2boiler64boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
34BK13/BK15/Smartline/GB1x2boiler64setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
35BK13/BK15/Smartline/GB1x2boiler64setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
36BK13/BK15/Smartline/GB1x2boiler64absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
37BK13/BK15/Smartline/GB1x2boiler64selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
38BK13/BK15/Smartline/GB1x2boiler64curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
39BK13/BK15/Smartline/GB1x2boiler64burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
40BK13/BK15/Smartline/GB1x2boiler64burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
41BK13/BK15/Smartline/GB1x2boiler64burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
42BK13/BK15/Smartline/GB1x2boiler64heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
43BK13/BK15/Smartline/GB1x2boiler64heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
44BK13/BK15/Smartline/GB1x2boiler64ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
45BK13/BK15/Smartline/GB1x2boiler64lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
46BK13/BK15/Smartline/GB1x2boiler64servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
47BK13/BK15/Smartline/GB1x2boiler64servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
48BK13/BK15/Smartline/GB1x2boiler64maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
49BK13/BK15/Smartline/GB1x2boiler64maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
50BK13/BK15/Smartline/GB1x2boiler64maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
51BK13/BK15/Smartline/GB1x2boiler64maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
52BK13/BK15/Smartline/GB1x2boiler64emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
53BK13/BK15/Smartline/GB1x2boiler64emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
54BK13/BK15/Smartline/GB1x2boiler64wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
55BK13/BK15/Smartline/GB1x2boiler64wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
56BK13/BK15/Smartline/GB1x2boiler64wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
57BK13/BK15/Smartline/GB1x2boiler64wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
58BK13/BK15/Smartline/GB1x2boiler64wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
59BK13/BK15/Smartline/GB1x2boiler64wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
60BK13/BK15/Smartline/GB1x2boiler64wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
61BK13/BK15/Smartline/GB1x2boiler64wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
62BK13/BK15/Smartline/GB1x2boiler64wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
63BK13/BK15/Smartline/GB1x2boiler64wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
64BK13/BK15/Smartline/GB1x2boiler64wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
65BK13/BK15/Smartline/GB1x2boiler64wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
66BK13/BK15/Smartline/GB1x2boiler64wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
67BK13/BK15/Smartline/GB1x2boiler64wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
68BK13/BK15/Smartline/GB1x2boiler64wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
69BK13/BK15/Smartline/GB1x2boiler64wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
70BK13/BK15/Smartline/GB1x2boiler64wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
71BK13/BK15/Smartline/GB1x2boiler64wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
72BK13/BK15/Smartline/GB1x2boiler64wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
73BK13/BK15/Smartline/GB1x2boiler64wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
74BK13/BK15/Smartline/GB1x2boiler64wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
75BK13/BK15/Smartline/GB1x2boiler64wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
76BK13/BK15/Smartline/GB1x2boiler64wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
77BK13/BK15/Smartline/GB1x2boiler64wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
78BK13/BK15/Smartline/GB1x2boiler64wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
79BK13/BK15/Smartline/GB1x2boiler64wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
80BK13/BK15/Smartline/GB1x2boiler64wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
81BK13/BK15/Smartline/GB1x2boiler64wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
82BK13/BK15/Smartline/GB1x2boiler64wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
83BK13/BK15/Smartline/GB1x2boiler64wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
84BK13/BK15/Smartline/GB1x2boiler64wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
85BK13/BK15/Smartline/GB1x2boiler64wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
86BK13/BK15/Smartline/GB1x2boiler64wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
87BK13/BK15/Smartline/GB1x2boiler64ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
88BK13/BK15/Smartline/GB1x2boiler64wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
89BK13/BK15/Smartline/GB1x2boiler64wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
90BK13/BK15/Smartline/GB1x2boiler64wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
91BK13/BK15/Smartline/GB1x2boiler64wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
92BK13/BK15/Smartline/GB1x2boiler64wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
93GB125/GB135/MC10boiler72resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
94GB125/GB135/MC10boiler72heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
95GB125/GB135/MC10boiler72tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
96GB125/GB135/MC10boiler72selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
97GB125/GB135/MC10boiler72heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
98GB125/GB135/MC10boiler72outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
99GB125/GB135/MC10boiler72curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
100GB125/GB135/MC10boiler72rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
101GB125/GB135/MC10boiler72switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
102GB125/GB135/MC10boiler72syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
103GB125/GB135/MC10boiler72boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
104GB125/GB135/MC10boiler72exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
105GB125/GB135/MC10boiler72burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
106GB125/GB135/MC10boiler72burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
107GB125/GB135/MC10boiler72flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
108GB125/GB135/MC10boiler72heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
109GB125/GB135/MC10boiler72fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
110GB125/GB135/MC10boiler72ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
111GB125/GB135/MC10boiler72oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
112GB125/GB135/MC10boiler72heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
113GB125/GB135/MC10boiler72heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
114GB125/GB135/MC10boiler72pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
115GB125/GB135/MC10boiler72pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
116GB125/GB135/MC10boiler72pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
117GB125/GB135/MC10boiler72pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
118GB125/GB135/MC10boiler72burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
119GB125/GB135/MC10boiler72burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
120GB125/GB135/MC10boiler72burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
121GB125/GB135/MC10boiler72boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
122GB125/GB135/MC10boiler72boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
123GB125/GB135/MC10boiler72boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
124GB125/GB135/MC10boiler72boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
125GB125/GB135/MC10boiler72setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
126GB125/GB135/MC10boiler72setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
127GB125/GB135/MC10boiler72absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
128GB125/GB135/MC10boiler72selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
129GB125/GB135/MC10boiler72curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
130GB125/GB135/MC10boiler72burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
131GB125/GB135/MC10boiler72burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
132GB125/GB135/MC10boiler72burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
133GB125/GB135/MC10boiler72heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
134GB125/GB135/MC10boiler72heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
135GB125/GB135/MC10boiler72ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
136GB125/GB135/MC10boiler72lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
137GB125/GB135/MC10boiler72servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
138GB125/GB135/MC10boiler72servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
139GB125/GB135/MC10boiler72maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
140GB125/GB135/MC10boiler72maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
141GB125/GB135/MC10boiler72maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
142GB125/GB135/MC10boiler72maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
143GB125/GB135/MC10boiler72emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
144GB125/GB135/MC10boiler72emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
145GB125/GB135/MC10boiler72wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
146GB125/GB135/MC10boiler72wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
147GB125/GB135/MC10boiler72wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
148GB125/GB135/MC10boiler72wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
149GB125/GB135/MC10boiler72wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
150GB125/GB135/MC10boiler72wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
151GB125/GB135/MC10boiler72wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
152GB125/GB135/MC10boiler72wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
153GB125/GB135/MC10boiler72wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
154GB125/GB135/MC10boiler72wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
155GB125/GB135/MC10boiler72wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
156GB125/GB135/MC10boiler72wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
157GB125/GB135/MC10boiler72wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
158GB125/GB135/MC10boiler72wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
159GB125/GB135/MC10boiler72wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
160GB125/GB135/MC10boiler72wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
161GB125/GB135/MC10boiler72wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
162GB125/GB135/MC10boiler72wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
163GB125/GB135/MC10boiler72wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
164GB125/GB135/MC10boiler72wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
165GB125/GB135/MC10boiler72wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
166GB125/GB135/MC10boiler72wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
167GB125/GB135/MC10boiler72wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
168GB125/GB135/MC10boiler72wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
169GB125/GB135/MC10boiler72wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
170GB125/GB135/MC10boiler72wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
171GB125/GB135/MC10boiler72wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
172GB125/GB135/MC10boiler72wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
173GB125/GB135/MC10boiler72wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
174GB125/GB135/MC10boiler72wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
175GB125/GB135/MC10boiler72wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
176GB125/GB135/MC10boiler72wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
177GB125/GB135/MC10boiler72wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
178GB125/GB135/MC10boiler72ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
179GB125/GB135/MC10boiler72wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
180GB125/GB135/MC10boiler72wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
181GB125/GB135/MC10boiler72wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
182GB125/GB135/MC10boiler72wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
183GB125/GB135/MC10boiler72wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
184Cascade CM10boiler81resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
185Cascade CM10boiler81heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
186Cascade CM10boiler81tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
187Cascade CM10boiler81selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
188Cascade CM10boiler81heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
189Cascade CM10boiler81outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
190Cascade CM10boiler81curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
191Cascade CM10boiler81rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
192Cascade CM10boiler81switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
193Cascade CM10boiler81syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
194Cascade CM10boiler81boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
195Cascade CM10boiler81exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
196Cascade CM10boiler81burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
197Cascade CM10boiler81burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
198Cascade CM10boiler81flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
199Cascade CM10boiler81heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
200Cascade CM10boiler81fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
201Cascade CM10boiler81ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
202Cascade CM10boiler81oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
203Cascade CM10boiler81heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
204Cascade CM10boiler81heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
205Cascade CM10boiler81pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
206Cascade CM10boiler81pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
207Cascade CM10boiler81pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
208Cascade CM10boiler81pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
209Cascade CM10boiler81burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
210Cascade CM10boiler81burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
211Cascade CM10boiler81burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
212Cascade CM10boiler81boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
213Cascade CM10boiler81boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
214Cascade CM10boiler81boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
215Cascade CM10boiler81boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
216Cascade CM10boiler81setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
217Cascade CM10boiler81setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
218Cascade CM10boiler81absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
219Cascade CM10boiler81selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
220Cascade CM10boiler81curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
221Cascade CM10boiler81burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
222Cascade CM10boiler81burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
223Cascade CM10boiler81burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
224Cascade CM10boiler81heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
225Cascade CM10boiler81heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
226Cascade CM10boiler81ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
227Cascade CM10boiler81lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
228Cascade CM10boiler81servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
229Cascade CM10boiler81servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
230Cascade CM10boiler81maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
231Cascade CM10boiler81maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
232Cascade CM10boiler81maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
233Cascade CM10boiler81maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
234Cascade CM10boiler81emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
235Cascade CM10boiler81emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
236Cascade CM10boiler81wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
237Cascade CM10boiler81wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
238Cascade CM10boiler81wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
239Cascade CM10boiler81wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
240Cascade CM10boiler81wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
241Cascade CM10boiler81wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
242Cascade CM10boiler81wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
243Cascade CM10boiler81wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
244Cascade CM10boiler81wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
245Cascade CM10boiler81wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
246Cascade CM10boiler81wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
247Cascade CM10boiler81wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
248Cascade CM10boiler81wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
249Cascade CM10boiler81wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
250Cascade CM10boiler81wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
251Cascade CM10boiler81wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
252Cascade CM10boiler81wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
253Cascade CM10boiler81wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
254Cascade CM10boiler81wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
255Cascade CM10boiler81wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
256Cascade CM10boiler81wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
257Cascade CM10boiler81wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
258Cascade CM10boiler81wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
259Cascade CM10boiler81wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
260Cascade CM10boiler81wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
261Cascade CM10boiler81wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
262Cascade CM10boiler81wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
263Cascade CM10boiler81wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
264Cascade CM10boiler81wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
265Cascade CM10boiler81wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
266Cascade CM10boiler81wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
267Cascade CM10boiler81wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
268Cascade CM10boiler81wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
269Cascade CM10boiler81ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
270Cascade CM10boiler81wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
271Cascade CM10boiler81wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
272Cascade CM10boiler81wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
273Cascade CM10boiler81wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
274Cascade CM10boiler81wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
275Logamax Plus GB022boiler84resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
276Logamax Plus GB022boiler84heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
277Logamax Plus GB022boiler84tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
278Logamax Plus GB022boiler84selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
279Logamax Plus GB022boiler84heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
280Logamax Plus GB022boiler84outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
281Logamax Plus GB022boiler84curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
282Logamax Plus GB022boiler84rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
283Logamax Plus GB022boiler84switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
284Logamax Plus GB022boiler84syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
285Logamax Plus GB022boiler84boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
286Logamax Plus GB022boiler84exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
287Logamax Plus GB022boiler84burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
288Logamax Plus GB022boiler84burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
289Logamax Plus GB022boiler84flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
290Logamax Plus GB022boiler84heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
291Logamax Plus GB022boiler84fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
292Logamax Plus GB022boiler84ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
293Logamax Plus GB022boiler84oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
294Logamax Plus GB022boiler84heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
295Logamax Plus GB022boiler84heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
296Logamax Plus GB022boiler84pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
297Logamax Plus GB022boiler84pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
298Logamax Plus GB022boiler84pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
299Logamax Plus GB022boiler84pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
300Logamax Plus GB022boiler84burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
301Logamax Plus GB022boiler84burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
302Logamax Plus GB022boiler84burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
303Logamax Plus GB022boiler84boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
304Logamax Plus GB022boiler84boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
305Logamax Plus GB022boiler84boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
306Logamax Plus GB022boiler84boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
307Logamax Plus GB022boiler84setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
308Logamax Plus GB022boiler84setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
309Logamax Plus GB022boiler84absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
310Logamax Plus GB022boiler84selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
311Logamax Plus GB022boiler84curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
312Logamax Plus GB022boiler84burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
313Logamax Plus GB022boiler84burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
314Logamax Plus GB022boiler84burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
315Logamax Plus GB022boiler84heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
316Logamax Plus GB022boiler84heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
317Logamax Plus GB022boiler84ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
318Logamax Plus GB022boiler84lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
319Logamax Plus GB022boiler84servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
320Logamax Plus GB022boiler84servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
321Logamax Plus GB022boiler84maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
322Logamax Plus GB022boiler84maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
323Logamax Plus GB022boiler84maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
324Logamax Plus GB022boiler84maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
325Logamax Plus GB022boiler84emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
326Logamax Plus GB022boiler84emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
327Logamax Plus GB022boiler84wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
328Logamax Plus GB022boiler84wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
329Logamax Plus GB022boiler84wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
330Logamax Plus GB022boiler84wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
331Logamax Plus GB022boiler84wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
332Logamax Plus GB022boiler84wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
333Logamax Plus GB022boiler84wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
334Logamax Plus GB022boiler84wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
335Logamax Plus GB022boiler84wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
336Logamax Plus GB022boiler84wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
337Logamax Plus GB022boiler84wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
338Logamax Plus GB022boiler84wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
339Logamax Plus GB022boiler84wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
340Logamax Plus GB022boiler84wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
341Logamax Plus GB022boiler84wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
342Logamax Plus GB022boiler84wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
343Logamax Plus GB022boiler84wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
344Logamax Plus GB022boiler84wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
345Logamax Plus GB022boiler84wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
346Logamax Plus GB022boiler84wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
347Logamax Plus GB022boiler84wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
348Logamax Plus GB022boiler84wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
349Logamax Plus GB022boiler84wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
350Logamax Plus GB022boiler84wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
351Logamax Plus GB022boiler84wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
352Logamax Plus GB022boiler84wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
353Logamax Plus GB022boiler84wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
354Logamax Plus GB022boiler84wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
355Logamax Plus GB022boiler84wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
356Logamax Plus GB022boiler84wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
357Logamax Plus GB022boiler84wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
358Logamax Plus GB022boiler84wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
359Logamax Plus GB022boiler84wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
360Logamax Plus GB022boiler84ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
361Logamax Plus GB022boiler84wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
362Logamax Plus GB022boiler84wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
363Logamax Plus GB022boiler84wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
364Logamax Plus GB022boiler84wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
365Logamax Plus GB022boiler84wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
366Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
367Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
368Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
369Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
370Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
371Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
372Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
373Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
374Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
375Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
376Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
377Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
378Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
379Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
380Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
381Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
382Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
383Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
384Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
385Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
386Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
387Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
388Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
389Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
390Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
391Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
392Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
393Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
394Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
395Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
396Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
397Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
398Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
399Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
400Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
401Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
402Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
403Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
404Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
405Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
406Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
407Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
408Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
409Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
410Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
411Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
412Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
413Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
414Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
415Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
416Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
417Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
418Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
419Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
420Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
421Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
422Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
423Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
424Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
425Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
426Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
427Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
428Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
429Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
430Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
431Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
432Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
433Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
434Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
435Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
436Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
437Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
438Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
439Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
440Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
441Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
442Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
443Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
444Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
445Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
446Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
447Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
448Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
449Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
450Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
451Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
452Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
453Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
454Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
455Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
456Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
457Topline/GB162boiler115resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
458Topline/GB162boiler115heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
459Topline/GB162boiler115tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
460Topline/GB162boiler115selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
461Topline/GB162boiler115heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
462Topline/GB162boiler115outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
463Topline/GB162boiler115curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
464Topline/GB162boiler115rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
465Topline/GB162boiler115switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
466Topline/GB162boiler115syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
467Topline/GB162boiler115boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
468Topline/GB162boiler115exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
469Topline/GB162boiler115burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
470Topline/GB162boiler115burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
471Topline/GB162boiler115flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
472Topline/GB162boiler115heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
473Topline/GB162boiler115fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
474Topline/GB162boiler115ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
475Topline/GB162boiler115oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
476Topline/GB162boiler115heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
477Topline/GB162boiler115heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
478Topline/GB162boiler115pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
479Topline/GB162boiler115pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
480Topline/GB162boiler115pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
481Topline/GB162boiler115pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
482Topline/GB162boiler115burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
483Topline/GB162boiler115burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
484Topline/GB162boiler115burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
485Topline/GB162boiler115boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
486Topline/GB162boiler115boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
487Topline/GB162boiler115boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
488Topline/GB162boiler115boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
489Topline/GB162boiler115setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
490Topline/GB162boiler115setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
491Topline/GB162boiler115absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
492Topline/GB162boiler115selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
493Topline/GB162boiler115curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
494Topline/GB162boiler115burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
495Topline/GB162boiler115burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
496Topline/GB162boiler115burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
497Topline/GB162boiler115heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
498Topline/GB162boiler115heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
499Topline/GB162boiler115ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
500Topline/GB162boiler115lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
501Topline/GB162boiler115servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
502Topline/GB162boiler115servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
503Topline/GB162boiler115maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
504Topline/GB162boiler115maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
505Topline/GB162boiler115maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
506Topline/GB162boiler115maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
507Topline/GB162boiler115emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
508Topline/GB162boiler115emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
509Topline/GB162boiler115wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
510Topline/GB162boiler115wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
511Topline/GB162boiler115wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
512Topline/GB162boiler115wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
513Topline/GB162boiler115wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
514Topline/GB162boiler115wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
515Topline/GB162boiler115wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
516Topline/GB162boiler115wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
517Topline/GB162boiler115wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
518Topline/GB162boiler115wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
519Topline/GB162boiler115wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
520Topline/GB162boiler115wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
521Topline/GB162boiler115wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
522Topline/GB162boiler115wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
523Topline/GB162boiler115wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
524Topline/GB162boiler115wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
525Topline/GB162boiler115wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
526Topline/GB162boiler115wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
527Topline/GB162boiler115wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
528Topline/GB162boiler115wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
529Topline/GB162boiler115wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
530Topline/GB162boiler115wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
531Topline/GB162boiler115wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
532Topline/GB162boiler115wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
533Topline/GB162boiler115wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
534Topline/GB162boiler115wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
535Topline/GB162boiler115wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
536Topline/GB162boiler115wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
537Topline/GB162boiler115wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
538Topline/GB162boiler115wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
539Topline/GB162boiler115wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
540Topline/GB162boiler115wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
541Topline/GB162boiler115wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
542Topline/GB162boiler115ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
543Topline/GB162boiler115wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
544Topline/GB162boiler115wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
545Topline/GB162boiler115wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
546Topline/GB162boiler115wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
547Topline/GB162boiler115wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
548Cascade MCM10boiler121resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
549Cascade MCM10boiler121heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
550Cascade MCM10boiler121tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
551Cascade MCM10boiler121selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
552Cascade MCM10boiler121heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
553Cascade MCM10boiler121outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
554Cascade MCM10boiler121curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
555Cascade MCM10boiler121rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
556Cascade MCM10boiler121switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
557Cascade MCM10boiler121syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
558Cascade MCM10boiler121boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
559Cascade MCM10boiler121exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
560Cascade MCM10boiler121burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
561Cascade MCM10boiler121burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
562Cascade MCM10boiler121flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
563Cascade MCM10boiler121heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
564Cascade MCM10boiler121fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
565Cascade MCM10boiler121ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
566Cascade MCM10boiler121oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
567Cascade MCM10boiler121heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
568Cascade MCM10boiler121heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
569Cascade MCM10boiler121pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
570Cascade MCM10boiler121pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
571Cascade MCM10boiler121pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
572Cascade MCM10boiler121pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
573Cascade MCM10boiler121burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
574Cascade MCM10boiler121burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
575Cascade MCM10boiler121burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
576Cascade MCM10boiler121boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
577Cascade MCM10boiler121boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
578Cascade MCM10boiler121boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
579Cascade MCM10boiler121boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
580Cascade MCM10boiler121setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
581Cascade MCM10boiler121setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
582Cascade MCM10boiler121absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
583Cascade MCM10boiler121selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
584Cascade MCM10boiler121curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
585Cascade MCM10boiler121burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
586Cascade MCM10boiler121burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
587Cascade MCM10boiler121burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
588Cascade MCM10boiler121heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
589Cascade MCM10boiler121heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
590Cascade MCM10boiler121ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
591Cascade MCM10boiler121lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
592Cascade MCM10boiler121servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
593Cascade MCM10boiler121servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
594Cascade MCM10boiler121maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
595Cascade MCM10boiler121maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
596Cascade MCM10boiler121maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
597Cascade MCM10boiler121maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
598Cascade MCM10boiler121emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
599Cascade MCM10boiler121emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
600Cascade MCM10boiler121wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
601Cascade MCM10boiler121wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
602Cascade MCM10boiler121wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
603Cascade MCM10boiler121wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
604Cascade MCM10boiler121wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
605Cascade MCM10boiler121wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
606Cascade MCM10boiler121wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
607Cascade MCM10boiler121wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
608Cascade MCM10boiler121wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
609Cascade MCM10boiler121wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
610Cascade MCM10boiler121wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
611Cascade MCM10boiler121wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
612Cascade MCM10boiler121wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
613Cascade MCM10boiler121wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
614Cascade MCM10boiler121wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
615Cascade MCM10boiler121wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
616Cascade MCM10boiler121wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
617Cascade MCM10boiler121wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
618Cascade MCM10boiler121wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
619Cascade MCM10boiler121wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
620Cascade MCM10boiler121wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
621Cascade MCM10boiler121wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
622Cascade MCM10boiler121wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
623Cascade MCM10boiler121wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
624Cascade MCM10boiler121wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
625Cascade MCM10boiler121wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
626Cascade MCM10boiler121wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
627Cascade MCM10boiler121wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
628Cascade MCM10boiler121wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
629Cascade MCM10boiler121wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
630Cascade MCM10boiler121wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
631Cascade MCM10boiler121wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
632Cascade MCM10boiler121wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
633Cascade MCM10boiler121ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
634Cascade MCM10boiler121wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
635Cascade MCM10boiler121wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
636Cascade MCM10boiler121wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
637Cascade MCM10boiler121wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
638Cascade MCM10boiler121wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
639Prolineboiler122resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
640Prolineboiler122heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
641Prolineboiler122tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
642Prolineboiler122selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
643Prolineboiler122heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
644Prolineboiler122outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
645Prolineboiler122curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
646Prolineboiler122rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
647Prolineboiler122switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
648Prolineboiler122syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
649Prolineboiler122boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
650Prolineboiler122exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
651Prolineboiler122burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
652Prolineboiler122burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
653Prolineboiler122flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
654Prolineboiler122heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
655Prolineboiler122fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
656Prolineboiler122ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
657Prolineboiler122oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
658Prolineboiler122heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
659Prolineboiler122heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
660Prolineboiler122pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
661Prolineboiler122pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
662Prolineboiler122pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
663Prolineboiler122pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
664Prolineboiler122burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
665Prolineboiler122burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
666Prolineboiler122burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
667Prolineboiler122boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
668Prolineboiler122boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
669Prolineboiler122boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
670Prolineboiler122boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
671Prolineboiler122setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
672Prolineboiler122setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
673Prolineboiler122absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
674Prolineboiler122selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
675Prolineboiler122curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
676Prolineboiler122burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
677Prolineboiler122burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
678Prolineboiler122burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
679Prolineboiler122heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
680Prolineboiler122heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
681Prolineboiler122ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
682Prolineboiler122lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
683Prolineboiler122servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
684Prolineboiler122servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
685Prolineboiler122maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
686Prolineboiler122maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
687Prolineboiler122maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
688Prolineboiler122maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
689Prolineboiler122emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
690Prolineboiler122emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
691Prolineboiler122wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
692Prolineboiler122wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
693Prolineboiler122wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
694Prolineboiler122wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
695Prolineboiler122wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
696Prolineboiler122wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
697Prolineboiler122wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
698Prolineboiler122wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
699Prolineboiler122wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
700Prolineboiler122wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
701Prolineboiler122wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
702Prolineboiler122wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
703Prolineboiler122wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
704Prolineboiler122wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
705Prolineboiler122wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
706Prolineboiler122wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
707Prolineboiler122wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
708Prolineboiler122wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
709Prolineboiler122wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
710Prolineboiler122wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
711Prolineboiler122wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
712Prolineboiler122wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
713Prolineboiler122wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
714Prolineboiler122wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
715Prolineboiler122wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
716Prolineboiler122wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
717Prolineboiler122wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
718Prolineboiler122wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
719Prolineboiler122wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
720Prolineboiler122wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
721Prolineboiler122wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
722Prolineboiler122wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
723Prolineboiler122wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
724Prolineboiler122ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
725Prolineboiler122wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
726Prolineboiler122wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
727Prolineboiler122wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
728Prolineboiler122wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
729Prolineboiler122wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
730GBx72/Trendline/Cerapur/Greenstar Siboiler123resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
731GBx72/Trendline/Cerapur/Greenstar Siboiler123heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
732GBx72/Trendline/Cerapur/Greenstar Siboiler123tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
733GBx72/Trendline/Cerapur/Greenstar Siboiler123selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
734GBx72/Trendline/Cerapur/Greenstar Siboiler123heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
735GBx72/Trendline/Cerapur/Greenstar Siboiler123outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
736GBx72/Trendline/Cerapur/Greenstar Siboiler123curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
737GBx72/Trendline/Cerapur/Greenstar Siboiler123rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
738GBx72/Trendline/Cerapur/Greenstar Siboiler123switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
739GBx72/Trendline/Cerapur/Greenstar Siboiler123syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
740GBx72/Trendline/Cerapur/Greenstar Siboiler123boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
741GBx72/Trendline/Cerapur/Greenstar Siboiler123exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
742GBx72/Trendline/Cerapur/Greenstar Siboiler123burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
743GBx72/Trendline/Cerapur/Greenstar Siboiler123burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
744GBx72/Trendline/Cerapur/Greenstar Siboiler123flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
745GBx72/Trendline/Cerapur/Greenstar Siboiler123heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
746GBx72/Trendline/Cerapur/Greenstar Siboiler123fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
747GBx72/Trendline/Cerapur/Greenstar Siboiler123ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
748GBx72/Trendline/Cerapur/Greenstar Siboiler123oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
749GBx72/Trendline/Cerapur/Greenstar Siboiler123heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
750GBx72/Trendline/Cerapur/Greenstar Siboiler123heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
751GBx72/Trendline/Cerapur/Greenstar Siboiler123pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
752GBx72/Trendline/Cerapur/Greenstar Siboiler123pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
753GBx72/Trendline/Cerapur/Greenstar Siboiler123pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
754GBx72/Trendline/Cerapur/Greenstar Siboiler123pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
755GBx72/Trendline/Cerapur/Greenstar Siboiler123burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
756GBx72/Trendline/Cerapur/Greenstar Siboiler123burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
757GBx72/Trendline/Cerapur/Greenstar Siboiler123burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
758GBx72/Trendline/Cerapur/Greenstar Siboiler123boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
759GBx72/Trendline/Cerapur/Greenstar Siboiler123boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
760GBx72/Trendline/Cerapur/Greenstar Siboiler123boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
761GBx72/Trendline/Cerapur/Greenstar Siboiler123boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
762GBx72/Trendline/Cerapur/Greenstar Siboiler123setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
763GBx72/Trendline/Cerapur/Greenstar Siboiler123setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
764GBx72/Trendline/Cerapur/Greenstar Siboiler123absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
765GBx72/Trendline/Cerapur/Greenstar Siboiler123selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
766GBx72/Trendline/Cerapur/Greenstar Siboiler123curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
767GBx72/Trendline/Cerapur/Greenstar Siboiler123burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
768GBx72/Trendline/Cerapur/Greenstar Siboiler123burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
769GBx72/Trendline/Cerapur/Greenstar Siboiler123burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
770GBx72/Trendline/Cerapur/Greenstar Siboiler123heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
771GBx72/Trendline/Cerapur/Greenstar Siboiler123heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
772GBx72/Trendline/Cerapur/Greenstar Siboiler123ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
773GBx72/Trendline/Cerapur/Greenstar Siboiler123lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
774GBx72/Trendline/Cerapur/Greenstar Siboiler123servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
775GBx72/Trendline/Cerapur/Greenstar Siboiler123servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
776GBx72/Trendline/Cerapur/Greenstar Siboiler123maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
777GBx72/Trendline/Cerapur/Greenstar Siboiler123maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
778GBx72/Trendline/Cerapur/Greenstar Siboiler123maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
779GBx72/Trendline/Cerapur/Greenstar Siboiler123maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
780GBx72/Trendline/Cerapur/Greenstar Siboiler123emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
781GBx72/Trendline/Cerapur/Greenstar Siboiler123emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
782GBx72/Trendline/Cerapur/Greenstar Siboiler123wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
783GBx72/Trendline/Cerapur/Greenstar Siboiler123wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
784GBx72/Trendline/Cerapur/Greenstar Siboiler123wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
785GBx72/Trendline/Cerapur/Greenstar Siboiler123wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
786GBx72/Trendline/Cerapur/Greenstar Siboiler123wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
787GBx72/Trendline/Cerapur/Greenstar Siboiler123wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
788GBx72/Trendline/Cerapur/Greenstar Siboiler123wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
789GBx72/Trendline/Cerapur/Greenstar Siboiler123wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
790GBx72/Trendline/Cerapur/Greenstar Siboiler123wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
791GBx72/Trendline/Cerapur/Greenstar Siboiler123wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
792GBx72/Trendline/Cerapur/Greenstar Siboiler123wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
793GBx72/Trendline/Cerapur/Greenstar Siboiler123wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
794GBx72/Trendline/Cerapur/Greenstar Siboiler123wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
795GBx72/Trendline/Cerapur/Greenstar Siboiler123wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
796GBx72/Trendline/Cerapur/Greenstar Siboiler123wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
797GBx72/Trendline/Cerapur/Greenstar Siboiler123wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
798GBx72/Trendline/Cerapur/Greenstar Siboiler123wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
799GBx72/Trendline/Cerapur/Greenstar Siboiler123wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
800GBx72/Trendline/Cerapur/Greenstar Siboiler123wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
801GBx72/Trendline/Cerapur/Greenstar Siboiler123wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
802GBx72/Trendline/Cerapur/Greenstar Siboiler123wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
803GBx72/Trendline/Cerapur/Greenstar Siboiler123wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
804GBx72/Trendline/Cerapur/Greenstar Siboiler123wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
805GBx72/Trendline/Cerapur/Greenstar Siboiler123wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
806GBx72/Trendline/Cerapur/Greenstar Siboiler123wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
807GBx72/Trendline/Cerapur/Greenstar Siboiler123wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
808GBx72/Trendline/Cerapur/Greenstar Siboiler123wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
809GBx72/Trendline/Cerapur/Greenstar Siboiler123wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
810GBx72/Trendline/Cerapur/Greenstar Siboiler123wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
811GBx72/Trendline/Cerapur/Greenstar Siboiler123wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
812GBx72/Trendline/Cerapur/Greenstar Siboiler123wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
813GBx72/Trendline/Cerapur/Greenstar Siboiler123wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
814GBx72/Trendline/Cerapur/Greenstar Siboiler123wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
815GBx72/Trendline/Cerapur/Greenstar Siboiler123ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
816GBx72/Trendline/Cerapur/Greenstar Siboiler123wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
817GBx72/Trendline/Cerapur/Greenstar Siboiler123wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
818GBx72/Trendline/Cerapur/Greenstar Siboiler123wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
819GBx72/Trendline/Cerapur/Greenstar Siboiler123wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
820GBx72/Trendline/Cerapur/Greenstar Siboiler123wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
821GB212boiler131resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
822GB212boiler131heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
823GB212boiler131tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
824GB212boiler131selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
825GB212boiler131heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
826GB212boiler131outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
827GB212boiler131curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
828GB212boiler131rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
829GB212boiler131switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
830GB212boiler131syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
831GB212boiler131boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
832GB212boiler131exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
833GB212boiler131burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
834GB212boiler131burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
835GB212boiler131flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
836GB212boiler131heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
837GB212boiler131fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
838GB212boiler131ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
839GB212boiler131oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
840GB212boiler131heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
841GB212boiler131heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
842GB212boiler131pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
843GB212boiler131pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
844GB212boiler131pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
845GB212boiler131pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
846GB212boiler131burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
847GB212boiler131burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
848GB212boiler131burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
849GB212boiler131boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
850GB212boiler131boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
851GB212boiler131boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
852GB212boiler131boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
853GB212boiler131setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
854GB212boiler131setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
855GB212boiler131absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
856GB212boiler131selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
857GB212boiler131curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
858GB212boiler131burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
859GB212boiler131burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
860GB212boiler131burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
861GB212boiler131heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
862GB212boiler131heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
863GB212boiler131ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
864GB212boiler131lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
865GB212boiler131servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
866GB212boiler131servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
867GB212boiler131maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
868GB212boiler131maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
869GB212boiler131maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
870GB212boiler131maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
871GB212boiler131emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
872GB212boiler131emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
873GB212boiler131wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
874GB212boiler131wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
875GB212boiler131wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
876GB212boiler131wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
877GB212boiler131wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
878GB212boiler131wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
879GB212boiler131wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
880GB212boiler131wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
881GB212boiler131wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
882GB212boiler131wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
883GB212boiler131wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
884GB212boiler131wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
885GB212boiler131wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
886GB212boiler131wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
887GB212boiler131wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
888GB212boiler131wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
889GB212boiler131wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
890GB212boiler131wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
891GB212boiler131wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
892GB212boiler131wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
893GB212boiler131wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
894GB212boiler131wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
895GB212boiler131wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
896GB212boiler131wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
897GB212boiler131wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
898GB212boiler131wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
899GB212boiler131wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
900GB212boiler131wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
901GB212boiler131wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
902GB212boiler131wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
903GB212boiler131wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
904GB212boiler131wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
905GB212boiler131wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
906GB212boiler131ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
907GB212boiler131wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
908GB212boiler131wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
909GB212boiler131wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
910GB212boiler131wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
911GB212boiler131wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
912GC7000Fboiler132resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
913GC7000Fboiler132heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
914GC7000Fboiler132tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
915GC7000Fboiler132selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
916GC7000Fboiler132heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
917GC7000Fboiler132outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
918GC7000Fboiler132curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
919GC7000Fboiler132rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
920GC7000Fboiler132switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
921GC7000Fboiler132syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
922GC7000Fboiler132boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
923GC7000Fboiler132exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
924GC7000Fboiler132burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
925GC7000Fboiler132burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
926GC7000Fboiler132flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
927GC7000Fboiler132heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
928GC7000Fboiler132fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
929GC7000Fboiler132ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
930GC7000Fboiler132oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
931GC7000Fboiler132heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
932GC7000Fboiler132heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
933GC7000Fboiler132pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
934GC7000Fboiler132pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
935GC7000Fboiler132pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
936GC7000Fboiler132pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
937GC7000Fboiler132burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
938GC7000Fboiler132burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
939GC7000Fboiler132burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
940GC7000Fboiler132boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
941GC7000Fboiler132boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
942GC7000Fboiler132boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
943GC7000Fboiler132boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
944GC7000Fboiler132setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
945GC7000Fboiler132setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
946GC7000Fboiler132absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
947GC7000Fboiler132selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
948GC7000Fboiler132curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
949GC7000Fboiler132burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
950GC7000Fboiler132burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
951GC7000Fboiler132burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
952GC7000Fboiler132heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
953GC7000Fboiler132heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
954GC7000Fboiler132ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
955GC7000Fboiler132lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
956GC7000Fboiler132servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
957GC7000Fboiler132servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
958GC7000Fboiler132maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
959GC7000Fboiler132maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
960GC7000Fboiler132maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
961GC7000Fboiler132maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
962GC7000Fboiler132emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
963GC7000Fboiler132emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
964GC7000Fboiler132wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
965GC7000Fboiler132wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
966GC7000Fboiler132wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
967GC7000Fboiler132wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
968GC7000Fboiler132wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
969GC7000Fboiler132wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
970GC7000Fboiler132wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
971GC7000Fboiler132wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
972GC7000Fboiler132wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
973GC7000Fboiler132wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
974GC7000Fboiler132wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
975GC7000Fboiler132wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
976GC7000Fboiler132wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
977GC7000Fboiler132wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
978GC7000Fboiler132wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
979GC7000Fboiler132wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
980GC7000Fboiler132wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
981GC7000Fboiler132wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
982GC7000Fboiler132wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
983GC7000Fboiler132wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
984GC7000Fboiler132wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
985GC7000Fboiler132wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
986GC7000Fboiler132wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
987GC7000Fboiler132wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
988GC7000Fboiler132wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
989GC7000Fboiler132wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
990GC7000Fboiler132wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
991GC7000Fboiler132wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
992GC7000Fboiler132wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
993GC7000Fboiler132wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
994GC7000Fboiler132wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
995GC7000Fboiler132wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
996GC7000Fboiler132wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
997GC7000Fboiler132ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
998GC7000Fboiler132wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
999GC7000Fboiler132wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
1000GC7000Fboiler132wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
1001GC7000Fboiler132wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
1002GC7000Fboiler132wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
1003Logano GB125/KB195i/Logamatic MC110boiler133resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
1004Logano GB125/KB195i/Logamatic MC110boiler133heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
1005Logano GB125/KB195i/Logamatic MC110boiler133tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
1006Logano GB125/KB195i/Logamatic MC110boiler133selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
1007Logano GB125/KB195i/Logamatic MC110boiler133heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
1008Logano GB125/KB195i/Logamatic MC110boiler133outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
1009Logano GB125/KB195i/Logamatic MC110boiler133curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
1010Logano GB125/KB195i/Logamatic MC110boiler133rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
1011Logano GB125/KB195i/Logamatic MC110boiler133switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
1012Logano GB125/KB195i/Logamatic MC110boiler133syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
1013Logano GB125/KB195i/Logamatic MC110boiler133boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
1014Logano GB125/KB195i/Logamatic MC110boiler133exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
1015Logano GB125/KB195i/Logamatic MC110boiler133burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
1016Logano GB125/KB195i/Logamatic MC110boiler133burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
1017Logano GB125/KB195i/Logamatic MC110boiler133flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
1018Logano GB125/KB195i/Logamatic MC110boiler133heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
1019Logano GB125/KB195i/Logamatic MC110boiler133fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
1020Logano GB125/KB195i/Logamatic MC110boiler133ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
1021Logano GB125/KB195i/Logamatic MC110boiler133oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
1022Logano GB125/KB195i/Logamatic MC110boiler133heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
1023Logano GB125/KB195i/Logamatic MC110boiler133heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
1024Logano GB125/KB195i/Logamatic MC110boiler133pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
1025Logano GB125/KB195i/Logamatic MC110boiler133pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
1026Logano GB125/KB195i/Logamatic MC110boiler133pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
1027Logano GB125/KB195i/Logamatic MC110boiler133pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
1028Logano GB125/KB195i/Logamatic MC110boiler133burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
1029Logano GB125/KB195i/Logamatic MC110boiler133burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
1030Logano GB125/KB195i/Logamatic MC110boiler133burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
1031Logano GB125/KB195i/Logamatic MC110boiler133boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
1032Logano GB125/KB195i/Logamatic MC110boiler133boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
1033Logano GB125/KB195i/Logamatic MC110boiler133boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
1034Logano GB125/KB195i/Logamatic MC110boiler133boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
1035Logano GB125/KB195i/Logamatic MC110boiler133setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
1036Logano GB125/KB195i/Logamatic MC110boiler133setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
1037Logano GB125/KB195i/Logamatic MC110boiler133absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
1038Logano GB125/KB195i/Logamatic MC110boiler133selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
1039Logano GB125/KB195i/Logamatic MC110boiler133curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
1040Logano GB125/KB195i/Logamatic MC110boiler133burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
1041Logano GB125/KB195i/Logamatic MC110boiler133burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
1042Logano GB125/KB195i/Logamatic MC110boiler133burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
1043Logano GB125/KB195i/Logamatic MC110boiler133heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
1044Logano GB125/KB195i/Logamatic MC110boiler133heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
1045Logano GB125/KB195i/Logamatic MC110boiler133ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
1046Logano GB125/KB195i/Logamatic MC110boiler133lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
1047Logano GB125/KB195i/Logamatic MC110boiler133servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
1048Logano GB125/KB195i/Logamatic MC110boiler133servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
1049Logano GB125/KB195i/Logamatic MC110boiler133maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
1050Logano GB125/KB195i/Logamatic MC110boiler133maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
1051Logano GB125/KB195i/Logamatic MC110boiler133maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
1052Logano GB125/KB195i/Logamatic MC110boiler133maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
1053Logano GB125/KB195i/Logamatic MC110boiler133emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
1054Logano GB125/KB195i/Logamatic MC110boiler133emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
1055Logano GB125/KB195i/Logamatic MC110boiler133wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
1056Logano GB125/KB195i/Logamatic MC110boiler133wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
1057Logano GB125/KB195i/Logamatic MC110boiler133wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
1058Logano GB125/KB195i/Logamatic MC110boiler133wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
1059Logano GB125/KB195i/Logamatic MC110boiler133wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
1060Logano GB125/KB195i/Logamatic MC110boiler133wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
1061Logano GB125/KB195i/Logamatic MC110boiler133wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
1062Logano GB125/KB195i/Logamatic MC110boiler133wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
1063Logano GB125/KB195i/Logamatic MC110boiler133wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
1064Logano GB125/KB195i/Logamatic MC110boiler133wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
1065Logano GB125/KB195i/Logamatic MC110boiler133wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
1066Logano GB125/KB195i/Logamatic MC110boiler133wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
1067Logano GB125/KB195i/Logamatic MC110boiler133wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
1068Logano GB125/KB195i/Logamatic MC110boiler133wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
1069Logano GB125/KB195i/Logamatic MC110boiler133wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
1070Logano GB125/KB195i/Logamatic MC110boiler133wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
1071Logano GB125/KB195i/Logamatic MC110boiler133wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
1072Logano GB125/KB195i/Logamatic MC110boiler133wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
1073Logano GB125/KB195i/Logamatic MC110boiler133wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
1074Logano GB125/KB195i/Logamatic MC110boiler133wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
1075Logano GB125/KB195i/Logamatic MC110boiler133wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
1076Logano GB125/KB195i/Logamatic MC110boiler133wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
1077Logano GB125/KB195i/Logamatic MC110boiler133wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
1078Logano GB125/KB195i/Logamatic MC110boiler133wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
1079Logano GB125/KB195i/Logamatic MC110boiler133wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
1080Logano GB125/KB195i/Logamatic MC110boiler133wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
1081Logano GB125/KB195i/Logamatic MC110boiler133wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
1082Logano GB125/KB195i/Logamatic MC110boiler133wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
1083Logano GB125/KB195i/Logamatic MC110boiler133wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
1084Logano GB125/KB195i/Logamatic MC110boiler133wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
1085Logano GB125/KB195i/Logamatic MC110boiler133wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
1086Logano GB125/KB195i/Logamatic MC110boiler133wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
1087Logano GB125/KB195i/Logamatic MC110boiler133wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
1088Logano GB125/KB195i/Logamatic MC110boiler133ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
1089Logano GB125/KB195i/Logamatic MC110boiler133wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
1090Logano GB125/KB195i/Logamatic MC110boiler133wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
1091Logano GB125/KB195i/Logamatic MC110boiler133wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
1092Logano GB125/KB195i/Logamatic MC110boiler133wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
1093Logano GB125/KB195i/Logamatic MC110boiler133wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
1094Greenstar 30Ri Compactboiler154resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
1095Greenstar 30Ri Compactboiler154heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
1096Greenstar 30Ri Compactboiler154tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
1097Greenstar 30Ri Compactboiler154selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
1098Greenstar 30Ri Compactboiler154heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
1099Greenstar 30Ri Compactboiler154outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
1100Greenstar 30Ri Compactboiler154curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
1101Greenstar 30Ri Compactboiler154rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
1102Greenstar 30Ri Compactboiler154switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
1103Greenstar 30Ri Compactboiler154syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
1104Greenstar 30Ri Compactboiler154boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
1105Greenstar 30Ri Compactboiler154exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
1106Greenstar 30Ri Compactboiler154burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
1107Greenstar 30Ri Compactboiler154burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
1108Greenstar 30Ri Compactboiler154flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
1109Greenstar 30Ri Compactboiler154heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
1110Greenstar 30Ri Compactboiler154fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
1111Greenstar 30Ri Compactboiler154ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
1112Greenstar 30Ri Compactboiler154oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
1113Greenstar 30Ri Compactboiler154heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
1114Greenstar 30Ri Compactboiler154heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
1115Greenstar 30Ri Compactboiler154pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
1116Greenstar 30Ri Compactboiler154pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
1117Greenstar 30Ri Compactboiler154pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
1118Greenstar 30Ri Compactboiler154pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
1119Greenstar 30Ri Compactboiler154burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
1120Greenstar 30Ri Compactboiler154burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
1121Greenstar 30Ri Compactboiler154burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
1122Greenstar 30Ri Compactboiler154boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
1123Greenstar 30Ri Compactboiler154boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
1124Greenstar 30Ri Compactboiler154boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
1125Greenstar 30Ri Compactboiler154boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
1126Greenstar 30Ri Compactboiler154setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
1127Greenstar 30Ri Compactboiler154setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
1128Greenstar 30Ri Compactboiler154absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
1129Greenstar 30Ri Compactboiler154selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
1130Greenstar 30Ri Compactboiler154curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
1131Greenstar 30Ri Compactboiler154burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
1132Greenstar 30Ri Compactboiler154burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
1133Greenstar 30Ri Compactboiler154burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
1134Greenstar 30Ri Compactboiler154heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
1135Greenstar 30Ri Compactboiler154heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
1136Greenstar 30Ri Compactboiler154ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
1137Greenstar 30Ri Compactboiler154lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
1138Greenstar 30Ri Compactboiler154servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
1139Greenstar 30Ri Compactboiler154servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
1140Greenstar 30Ri Compactboiler154maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
1141Greenstar 30Ri Compactboiler154maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
1142Greenstar 30Ri Compactboiler154maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
1143Greenstar 30Ri Compactboiler154maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
1144Greenstar 30Ri Compactboiler154emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
1145Greenstar 30Ri Compactboiler154emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
1146Greenstar 30Ri Compactboiler154wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
1147Greenstar 30Ri Compactboiler154wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
1148Greenstar 30Ri Compactboiler154wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
1149Greenstar 30Ri Compactboiler154wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
1150Greenstar 30Ri Compactboiler154wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
1151Greenstar 30Ri Compactboiler154wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
1152Greenstar 30Ri Compactboiler154wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
1153Greenstar 30Ri Compactboiler154wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
1154Greenstar 30Ri Compactboiler154wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
1155Greenstar 30Ri Compactboiler154wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
1156Greenstar 30Ri Compactboiler154wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
1157Greenstar 30Ri Compactboiler154wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
1158Greenstar 30Ri Compactboiler154wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
1159Greenstar 30Ri Compactboiler154wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
1160Greenstar 30Ri Compactboiler154wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
1161Greenstar 30Ri Compactboiler154wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
1162Greenstar 30Ri Compactboiler154wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
1163Greenstar 30Ri Compactboiler154wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
1164Greenstar 30Ri Compactboiler154wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
1165Greenstar 30Ri Compactboiler154wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
1166Greenstar 30Ri Compactboiler154wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
1167Greenstar 30Ri Compactboiler154wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
1168Greenstar 30Ri Compactboiler154wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
1169Greenstar 30Ri Compactboiler154wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
1170Greenstar 30Ri Compactboiler154wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
1171Greenstar 30Ri Compactboiler154wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
1172Greenstar 30Ri Compactboiler154wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
1173Greenstar 30Ri Compactboiler154wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
1174Greenstar 30Ri Compactboiler154wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
1175Greenstar 30Ri Compactboiler154wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
1176Greenstar 30Ri Compactboiler154wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
1177Greenstar 30Ri Compactboiler154wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
1178Greenstar 30Ri Compactboiler154wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
1179Greenstar 30Ri Compactboiler154ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
1180Greenstar 30Ri Compactboiler154wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
1181Greenstar 30Ri Compactboiler154wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
1182Greenstar 30Ri Compactboiler154wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
1183Greenstar 30Ri Compactboiler154wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
1184Greenstar 30Ri Compactboiler154wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
1185Cerapur Aeroboiler167resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
1186Cerapur Aeroboiler167heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
1187Cerapur Aeroboiler167tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
1188Cerapur Aeroboiler167selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
1189Cerapur Aeroboiler167heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
1190Cerapur Aeroboiler167outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
1191Cerapur Aeroboiler167curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
1192Cerapur Aeroboiler167rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
1193Cerapur Aeroboiler167switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
1194Cerapur Aeroboiler167syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
1195Cerapur Aeroboiler167boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
1196Cerapur Aeroboiler167exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
1197Cerapur Aeroboiler167burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
1198Cerapur Aeroboiler167burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
1199Cerapur Aeroboiler167flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
1200Cerapur Aeroboiler167heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
1201Cerapur Aeroboiler167fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
1202Cerapur Aeroboiler167ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
1203Cerapur Aeroboiler167oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
1204Cerapur Aeroboiler167heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
1205Cerapur Aeroboiler167heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
1206Cerapur Aeroboiler167pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
1207Cerapur Aeroboiler167pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
1208Cerapur Aeroboiler167pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
1209Cerapur Aeroboiler167pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
1210Cerapur Aeroboiler167burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
1211Cerapur Aeroboiler167burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
1212Cerapur Aeroboiler167burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
1213Cerapur Aeroboiler167boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
1214Cerapur Aeroboiler167boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
1215Cerapur Aeroboiler167boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
1216Cerapur Aeroboiler167boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
1217Cerapur Aeroboiler167setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
1218Cerapur Aeroboiler167setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
1219Cerapur Aeroboiler167absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
1220Cerapur Aeroboiler167selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
1221Cerapur Aeroboiler167curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
1222Cerapur Aeroboiler167burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
1223Cerapur Aeroboiler167burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
1224Cerapur Aeroboiler167burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
1225Cerapur Aeroboiler167heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
1226Cerapur Aeroboiler167heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
1227Cerapur Aeroboiler167ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
1228Cerapur Aeroboiler167lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
1229Cerapur Aeroboiler167servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
1230Cerapur Aeroboiler167servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
1231Cerapur Aeroboiler167maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
1232Cerapur Aeroboiler167maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
1233Cerapur Aeroboiler167maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
1234Cerapur Aeroboiler167maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
1235Cerapur Aeroboiler167emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
1236Cerapur Aeroboiler167emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
1237Cerapur Aeroboiler167wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
1238Cerapur Aeroboiler167wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
1239Cerapur Aeroboiler167wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
1240Cerapur Aeroboiler167wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
1241Cerapur Aeroboiler167wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
1242Cerapur Aeroboiler167wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
1243Cerapur Aeroboiler167wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
1244Cerapur Aeroboiler167wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
1245Cerapur Aeroboiler167wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
1246Cerapur Aeroboiler167wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
1247Cerapur Aeroboiler167wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
1248Cerapur Aeroboiler167wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
1249Cerapur Aeroboiler167wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
1250Cerapur Aeroboiler167wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
1251Cerapur Aeroboiler167wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
1252Cerapur Aeroboiler167wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
1253Cerapur Aeroboiler167wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
1254Cerapur Aeroboiler167wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
1255Cerapur Aeroboiler167wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
1256Cerapur Aeroboiler167wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
1257Cerapur Aeroboiler167wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
1258Cerapur Aeroboiler167wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
1259Cerapur Aeroboiler167wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
1260Cerapur Aeroboiler167wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
1261Cerapur Aeroboiler167wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
1262Cerapur Aeroboiler167wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
1263Cerapur Aeroboiler167wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
1264Cerapur Aeroboiler167wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
1265Cerapur Aeroboiler167wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
1266Cerapur Aeroboiler167wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
1267Cerapur Aeroboiler167wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
1268Cerapur Aeroboiler167wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
1269Cerapur Aeroboiler167wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
1270Cerapur Aeroboiler167ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
1271Cerapur Aeroboiler167wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
1272Cerapur Aeroboiler167wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
1273Cerapur Aeroboiler167wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
1274Cerapur Aeroboiler167wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
1275Cerapur Aeroboiler167wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
1276Hybrid Heatpumpboiler168resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
1277Hybrid Heatpumpboiler168heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
1278Hybrid Heatpumpboiler168tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
1279Hybrid Heatpumpboiler168selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
1280Hybrid Heatpumpboiler168heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
1281Hybrid Heatpumpboiler168outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
1282Hybrid Heatpumpboiler168curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
1283Hybrid Heatpumpboiler168rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
1284Hybrid Heatpumpboiler168switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
1285Hybrid Heatpumpboiler168syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
1286Hybrid Heatpumpboiler168boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
1287Hybrid Heatpumpboiler168exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
1288Hybrid Heatpumpboiler168burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
1289Hybrid Heatpumpboiler168burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
1290Hybrid Heatpumpboiler168flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
1291Hybrid Heatpumpboiler168heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
1292Hybrid Heatpumpboiler168fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
1293Hybrid Heatpumpboiler168ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
1294Hybrid Heatpumpboiler168oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
1295Hybrid Heatpumpboiler168heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
1296Hybrid Heatpumpboiler168heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
1297Hybrid Heatpumpboiler168pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
1298Hybrid Heatpumpboiler168pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
1299Hybrid Heatpumpboiler168pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
1300Hybrid Heatpumpboiler168pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
1301Hybrid Heatpumpboiler168burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
1302Hybrid Heatpumpboiler168burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
1303Hybrid Heatpumpboiler168burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
1304Hybrid Heatpumpboiler168boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
1305Hybrid Heatpumpboiler168boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
1306Hybrid Heatpumpboiler168boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
1307Hybrid Heatpumpboiler168boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
1308Hybrid Heatpumpboiler168setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
1309Hybrid Heatpumpboiler168setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
1310Hybrid Heatpumpboiler168absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
1311Hybrid Heatpumpboiler168selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
1312Hybrid Heatpumpboiler168curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
1313Hybrid Heatpumpboiler168burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
1314Hybrid Heatpumpboiler168burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
1315Hybrid Heatpumpboiler168burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
1316Hybrid Heatpumpboiler168heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
1317Hybrid Heatpumpboiler168heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
1318Hybrid Heatpumpboiler168ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
1319Hybrid Heatpumpboiler168lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
1320Hybrid Heatpumpboiler168servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
1321Hybrid Heatpumpboiler168servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
1322Hybrid Heatpumpboiler168maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
1323Hybrid Heatpumpboiler168maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
1324Hybrid Heatpumpboiler168maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
1325Hybrid Heatpumpboiler168maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
1326Hybrid Heatpumpboiler168emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
1327Hybrid Heatpumpboiler168emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
1328Hybrid Heatpumpboiler168wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
1329Hybrid Heatpumpboiler168wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
1330Hybrid Heatpumpboiler168wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
1331Hybrid Heatpumpboiler168wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
1332Hybrid Heatpumpboiler168wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
1333Hybrid Heatpumpboiler168wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
1334Hybrid Heatpumpboiler168wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
1335Hybrid Heatpumpboiler168wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
1336Hybrid Heatpumpboiler168wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
1337Hybrid Heatpumpboiler168wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
1338Hybrid Heatpumpboiler168wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
1339Hybrid Heatpumpboiler168wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
1340Hybrid Heatpumpboiler168wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
1341Hybrid Heatpumpboiler168wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
1342Hybrid Heatpumpboiler168wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
1343Hybrid Heatpumpboiler168wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
1344Hybrid Heatpumpboiler168wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
1345Hybrid Heatpumpboiler168wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
1346Hybrid Heatpumpboiler168wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
1347Hybrid Heatpumpboiler168wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
1348Hybrid Heatpumpboiler168wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
1349Hybrid Heatpumpboiler168wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
1350Hybrid Heatpumpboiler168wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
1351Hybrid Heatpumpboiler168wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
1352Hybrid Heatpumpboiler168wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
1353Hybrid Heatpumpboiler168wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
1354Hybrid Heatpumpboiler168wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
1355Hybrid Heatpumpboiler168wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
1356Hybrid Heatpumpboiler168wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
1357Hybrid Heatpumpboiler168wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
1358Hybrid Heatpumpboiler168wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
1359Hybrid Heatpumpboiler168wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
1360Hybrid Heatpumpboiler168wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
1361Hybrid Heatpumpboiler168ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
1362Hybrid Heatpumpboiler168wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
1363Hybrid Heatpumpboiler168wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
1364Hybrid Heatpumpboiler168wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
1365Hybrid Heatpumpboiler168wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
1366Hybrid Heatpumpboiler168wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
1367Logano GB212boiler170resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
1368Logano GB212boiler170heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
1369Logano GB212boiler170tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
1370Logano GB212boiler170selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
1371Logano GB212boiler170heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
1372Logano GB212boiler170outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
1373Logano GB212boiler170curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
1374Logano GB212boiler170rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
1375Logano GB212boiler170switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
1376Logano GB212boiler170syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
1377Logano GB212boiler170boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
1378Logano GB212boiler170exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
1379Logano GB212boiler170burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
1380Logano GB212boiler170burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
1381Logano GB212boiler170flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
1382Logano GB212boiler170heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
1383Logano GB212boiler170fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
1384Logano GB212boiler170ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
1385Logano GB212boiler170oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
1386Logano GB212boiler170heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
1387Logano GB212boiler170heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
1388Logano GB212boiler170pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
1389Logano GB212boiler170pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
1390Logano GB212boiler170pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
1391Logano GB212boiler170pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
1392Logano GB212boiler170burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
1393Logano GB212boiler170burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
1394Logano GB212boiler170burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
1395Logano GB212boiler170boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
1396Logano GB212boiler170boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
1397Logano GB212boiler170boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
1398Logano GB212boiler170boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
1399Logano GB212boiler170setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
1400Logano GB212boiler170setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
1401Logano GB212boiler170absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
1402Logano GB212boiler170selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
1403Logano GB212boiler170curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
1404Logano GB212boiler170burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
1405Logano GB212boiler170burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
1406Logano GB212boiler170burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
1407Logano GB212boiler170heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
1408Logano GB212boiler170heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
1409Logano GB212boiler170ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
1410Logano GB212boiler170lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
1411Logano GB212boiler170servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
1412Logano GB212boiler170servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
1413Logano GB212boiler170maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
1414Logano GB212boiler170maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
1415Logano GB212boiler170maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
1416Logano GB212boiler170maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
1417Logano GB212boiler170emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
1418Logano GB212boiler170emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
1419Logano GB212boiler170wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
1420Logano GB212boiler170wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
1421Logano GB212boiler170wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
1422Logano GB212boiler170wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
1423Logano GB212boiler170wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
1424Logano GB212boiler170wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
1425Logano GB212boiler170wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
1426Logano GB212boiler170wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
1427Logano GB212boiler170wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
1428Logano GB212boiler170wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
1429Logano GB212boiler170wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
1430Logano GB212boiler170wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
1431Logano GB212boiler170wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
1432Logano GB212boiler170wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
1433Logano GB212boiler170wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
1434Logano GB212boiler170wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
1435Logano GB212boiler170wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
1436Logano GB212boiler170wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
1437Logano GB212boiler170wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
1438Logano GB212boiler170wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
1439Logano GB212boiler170wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
1440Logano GB212boiler170wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
1441Logano GB212boiler170wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
1442Logano GB212boiler170wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
1443Logano GB212boiler170wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
1444Logano GB212boiler170wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
1445Logano GB212boiler170wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
1446Logano GB212boiler170wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
1447Logano GB212boiler170wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
1448Logano GB212boiler170wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
1449Logano GB212boiler170wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
1450Logano GB212boiler170wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
1451Logano GB212boiler170wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
1452Logano GB212boiler170ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
1453Logano GB212boiler170wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
1454Logano GB212boiler170wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
1455Logano GB212boiler170wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
1456Logano GB212boiler170wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
1457Logano GB212boiler170wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
1458Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
1459Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
1460Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
1461Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
1462Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
1463Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
1464Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
1465Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
1466Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
1467Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
1468Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
1469Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
1470Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
1471Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
1472Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
1473Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
1474Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
1475Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
1476Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
1477Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
1478Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
1479Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
1480Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
1481Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
1482Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
1483Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
1484Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
1485Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
1486Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
1487Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
1488Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
1489Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
1490Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
1491Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
1492Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
1493Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
1494Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
1495Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
1496Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
1497Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
1498Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
1499Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
1500Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
1501Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
1502Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
1503Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
1504Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
1505Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
1506Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
1507Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
1508Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
1509Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
1510Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172uptimecontroltotal operating time heattime (>=0<=17476)minutesfalsesensor.boiler_total_operating_time_heatsensor.boiler_uptimecontrol
1511Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172uptimecompheatingoperating time compressor heatingtime (>=0<=17476)minutesfalsesensor.boiler_operating_time_compressor_heatingsensor.boiler_uptimecompheating
1512Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172uptimecompcoolingoperating time compressor coolingtime (>=0<=17476)minutesfalsesensor.boiler_operating_time_compressor_coolingsensor.boiler_uptimecompcooling
1513Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172uptimecompwwoperating time compressor dhwtime (>=0<=17476)minutesfalsesensor.boiler_operating_time_compressor_dhwsensor.boiler_uptimecompww
1514Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172uptimecomppooloperating time compressor pooltime (>=0<=17476)minutesfalsesensor.boiler_operating_time_compressor_poolsensor.boiler_uptimecomppool
1515Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172totalcompstartstotal compressor control startsulong (>=0<=65533)falsesensor.boiler_total_compressor_control_startssensor.boiler_totalcompstarts
1516Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatingstartsheating control startsulong (>=0<=65533)falsesensor.boiler_heating_control_startssensor.boiler_heatingstarts
1517Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172coolingstartscooling control startsulong (>=0<=65533)falsesensor.boiler_cooling_control_startssensor.boiler_coolingstarts
1518Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwstarts2control starts2ulong (>=0<=65533)falsesensor.boiler_control_starts2sensor.boiler_wwstarts2
1519Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172poolstartspool control startsulong (>=0<=65533)falsesensor.boiler_pool_control_startssensor.boiler_poolstarts
1520Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgconstotaltotal energy consumptionulong (>=0<=65533)kWhfalsesensor.boiler_total_energy_consumptionsensor.boiler_nrgconstotal
1521Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgconscomptotaltotal energy consumption compressorulong (>=0<=65533)kWhfalsesensor.boiler_total_energy_consumption_compressorsensor.boiler_nrgconscomptotal
1522Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgconscompheatingenergy consumption compressor heatingulong (>=0<=65533)kWhfalsesensor.boiler_energy_consumption_compressor_heatingsensor.boiler_nrgconscompheating
1523Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgconscompwwenergy consumption compressor dhwulong (>=0<=65533)kWhfalsesensor.boiler_energy_consumption_compressor_dhwsensor.boiler_nrgconscompww
1524Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgconscompcoolingenergy consumption compressor coolingulong (>=0<=65533)kWhfalsesensor.boiler_energy_consumption_compressor_coolingsensor.boiler_nrgconscompcooling
1525Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgconscomppoolenergy consumption compressor poolulong (>=0<=65533)kWhfalsesensor.boiler_energy_consumption_compressor_poolsensor.boiler_nrgconscomppool
1526Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxelecheatnrgconstotaltotal aux elec. heater energy consumptionulong (>=0<=65533)kWhfalsesensor.boiler_total_aux_elec._heater_energy_consumptionsensor.boiler_auxelecheatnrgconstotal
1527Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxelecheatnrgconsheatingaux elec. heater energy consumption heatingulong (>=0<=65533)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_heatingsensor.boiler_auxelecheatnrgconsheating
1528Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxelecheatnrgconswwaux elec. heater energy consumption dhwulong (>=0<=65533)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_dhwsensor.boiler_auxelecheatnrgconsww
1529Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxelecheatnrgconspoolaux elec. heater energy consumption poolulong (>=0<=65533)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_poolsensor.boiler_auxelecheatnrgconspool
1530Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgsupptotaltotal energy suppliedulong (>=0<=65533)kWhfalsesensor.boiler_total_energy_suppliedsensor.boiler_nrgsupptotal
1531Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgsuppheatingtotal energy supplied heatingulong (>=0<=65533)kWhfalsesensor.boiler_total_energy_supplied_heatingsensor.boiler_nrgsuppheating
1532Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgsuppwwtotal energy warm supplied dhwulong (>=0<=65533)kWhfalsesensor.boiler_total_energy_warm_supplied_dhwsensor.boiler_nrgsuppww
1533Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgsuppcoolingtotal energy supplied coolingulong (>=0<=65533)kWhfalsesensor.boiler_total_energy_supplied_coolingsensor.boiler_nrgsuppcooling
1534Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgsupppooltotal energy supplied poolulong (>=0<=65533)kWhfalsesensor.boiler_total_energy_supplied_poolsensor.boiler_nrgsupppool
1535Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hppowercompressor power outputuint (>=0<=25)kWfalsesensor.boiler_compressor_power_outputsensor.boiler_hppower
1536Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpcomponhp compressorbooleanfalsebinary_sensor.boiler_hp_compressorbinary_sensor.boiler_hpcompon
1537Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpactivitycompressor activityenum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost]falsesensor.boiler_compressor_activitysensor.boiler_hpactivity
1538Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpheatingonhp heatingbooleanfalsebinary_sensor.boiler_hp_heatingbinary_sensor.boiler_hpheatingon
1539Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpcoolingonhp coolingbooleanfalsebinary_sensor.boiler_hp_coolingbinary_sensor.boiler_hpcoolingon
1540Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpwwonhp dhwbooleanfalsebinary_sensor.boiler_hp_dhwbinary_sensor.boiler_hpwwon
1541Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hppoolonhp poolbooleanfalsebinary_sensor.boiler_hp_poolbinary_sensor.boiler_hppoolon
1542Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpbrinepumpspdbrine pump speeduint (>=0<=100)%falsesensor.boiler_brine_pump_speedsensor.boiler_hpbrinepumpspd
1543Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpswitchvalveswitch valvebooleanfalsebinary_sensor.boiler_switch_valvebinary_sensor.boiler_hpswitchvalve
1544Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpcompspdcompressor speeduint (>=0<=100)%falsesensor.boiler_compressor_speedsensor.boiler_hpcompspd
1545Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpcircspdcirculation pump speeduint (>=0<=100)%falsesensor.boiler_circulation_pump_speedsensor.boiler_hpcircspd
1546Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpbrineinbrine in/evaporatorshort (>=-3199<=3199)Cfalsesensor.boiler_brine_in/evaporatorsensor.boiler_hpbrinein
1547Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpbrineoutbrine out/condensershort (>=-3199<=3199)Cfalsesensor.boiler_brine_out/condensersensor.boiler_hpbrineout
1548Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptc0heat carrier return (TC0)short (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_return_(TC0)sensor.boiler_hptc0
1549Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptc1heat carrier forward (TC1)short (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_forward_(TC1)sensor.boiler_hptc1
1550Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptc3condenser temperature (TC3)short (>=-3199<=3199)Cfalsesensor.boiler_condenser_temperature_(TC3)sensor.boiler_hptc3
1551Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptr1compressor temperature (TR1)short (>=-3199<=3199)Cfalsesensor.boiler_compressor_temperature_(TR1)sensor.boiler_hptr1
1552Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptr3refrigerant temperature liquid side (condenser output) (TR3)short (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3)sensor.boiler_hptr3
1553Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptr4evaporator inlet temperature (TR4)short (>=-3199<=3199)Cfalsesensor.boiler_evaporator_inlet_temperature_(TR4)sensor.boiler_hptr4
1554Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptr5compressor inlet temperature (TR5)short (>=-3199<=3199)Cfalsesensor.boiler_compressor_inlet_temperature_(TR5)sensor.boiler_hptr5
1555Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptr6compressor outlet temperature (TR6)short (>=-3199<=3199)Cfalsesensor.boiler_compressor_outlet_temperature_(TR6)sensor.boiler_hptr6
1556Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptr7refrigerant temperature gas side (condenser input) (TR7)short (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7)sensor.boiler_hptr7
1557Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptl2air inlet temperature (TL2)short (>=-3199<=3199)Cfalsesensor.boiler_air_inlet_temperature_(TL2)sensor.boiler_hptl2
1558Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hppl1low pressure side temperature (PL1)short (>=-3199<=3199)Cfalsesensor.boiler_low_pressure_side_temperature_(PL1)sensor.boiler_hppl1
1559Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpph1high pressure side temperature (PH1)short (>=-3199<=3199)Cfalsesensor.boiler_high_pressure_side_temperature_(PH1)sensor.boiler_hpph1
1560Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172poolsettemppool set temperatureuint (>=0<=127)Ctruenumber.boiler_pool_set_temperaturenumber.boiler_poolsettemp
1561Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpin1optinput 1 optionsstringtruesensor.boiler_input_1_optionssensor.boiler_hpin1opt
1562Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpin2optinput 2 optionsstringtruesensor.boiler_input_2_optionssensor.boiler_hpin2opt
1563Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpin3optinput 3 optionsstringtruesensor.boiler_input_3_optionssensor.boiler_hpin3opt
1564Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpin4optinput 4 optionsstringtruesensor.boiler_input_4_optionssensor.boiler_hpin4opt
1565Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maxheatcompheat limit compressorenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_compressorselect.boiler_maxheatcomp
1566Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maxheatheatheat limit heatingenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_heatingselect.boiler_maxheatheat
1567Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maxheatdhwheat limit dhwenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_dhwselect.boiler_maxheatdhw
1568Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172mandefrostmanual defrostbooleantrueswitch.boiler_manual_defrostswitch.boiler_mandefrost
1569Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172pvcoolingCooling only with PVbooleantrueswitch.boiler_Cooling_only_with_PVswitch.boiler_pvcooling
1570Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxheateronlyaux heater onlybooleantrueswitch.boiler_aux_heater_onlyswitch.boiler_auxheateronly
1571Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxheateroffdisable aux heaterbooleantrueswitch.boiler_disable_aux_heaterswitch.boiler_auxheateroff
1572Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxheaterstatusaux heater statusbooleanfalsebinary_sensor.boiler_aux_heater_statusbinary_sensor.boiler_auxheaterstatus
1573Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxheaterdelayaux heater on delayushort (>=10<=1000)K*mintruenumber.boiler_aux_heater_on_delaynumber.boiler_auxheaterdelay
1574Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxmaxlimitaux heater max limituint (>=0<=10)Ktruenumber.boiler_aux_heater_max_limitnumber.boiler_auxmaxlimit
1575Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxlimitstartaux heater limit startuint (>=0<=10)Ktruenumber.boiler_aux_heater_limit_startnumber.boiler_auxlimitstart
1576Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxheatrmodeaux heater modeenum [eco\|comfort]trueselect.boiler_aux_heater_modeselect.boiler_auxheatrmode
1577Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hphystheaton/off hyst heatushort (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_heatnumber.boiler_hphystheat
1578Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hphystcoolon/off hyst coolushort (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_coolnumber.boiler_hphystcool
1579Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hphystpoolon/off hyst poolushort (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_poolnumber.boiler_hphystpool
1580Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172silentmodesilent modeenum [off\|auto\|on]trueselect.boiler_silent_modeselect.boiler_silentmode
1581Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172silentfromsilent mode fromuint (>=0<=3810)minutestruenumber.boiler_silent_mode_fromnumber.boiler_silentfrom
1582Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172silenttosilent mode touint (>=0<=3810)minutestruenumber.boiler_silent_mode_tonumber.boiler_silentto
1583Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172mintempsilentmin outside temp for silent modeint (>=-126<=126)Ctruenumber.boiler_min_outside_temp_for_silent_modenumber.boiler_mintempsilent
1584Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172tempparmodeoutside temp parallel modeint (>=-126<=126)Ctruenumber.boiler_outside_temp_parallel_modenumber.boiler_tempparmode
1585Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxheatmixaux heater mixing valveint (>=-100<=100)%falsesensor.boiler_aux_heater_mixing_valvesensor.boiler_auxheatmix
1586Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172tempdiffheattemp diff TC3/TC0 heatuint (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_heatnumber.boiler_tempdiffheat
1587Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172tempdiffcooltemp diff TC3/TC0 cooluint (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_coolnumber.boiler_tempdiffcool
1588Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172vpcoolingvalve/pump coolingbooleantrueswitch.boiler_valve/pump_coolingswitch.boiler_vpcooling
1589Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatcableheating cablebooleantrueswitch.boiler_heating_cableswitch.boiler_heatcable
1590Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172vc0valveVC0 valvebooleantrueswitch.boiler_VC0_valveswitch.boiler_vc0valve
1591Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172primepumpprimary heatpumpbooleantrueswitch.boiler_primary_heatpumpswitch.boiler_primepump
1592Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172primepumpmodprimary heatpump modulationuint (>=0<=100)%truenumber.boiler_primary_heatpump_modulationnumber.boiler_primepumpmod
1593Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hp3way3-way valvebooleantrueswitch.boiler_3-way_valveswitch.boiler_hp3way
1594Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172elheatstep1el. heater step 1booleantrueswitch.boiler_el._heater_step_1switch.boiler_elheatstep1
1595Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172elheatstep2el. heater step 2booleantrueswitch.boiler_el._heater_step_2switch.boiler_elheatstep2
1596Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172elheatstep3el. heater step 3booleantrueswitch.boiler_el._heater_step_3switch.boiler_elheatstep3
1597Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwalternatingopalternating operationbooleantrueswitch.boiler_alternating_operationswitch.boiler_wwalternatingop
1598Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwaltopprioheatprioritise heating during dhwuint (>=20<=120)minutestruenumber.boiler_prioritise_heating_during_dhwnumber.boiler_wwaltopprioheat
1599Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwaltoppriowwprioritise dhw during heatinguint (>=30<=120)minutestruenumber.boiler_prioritise_dhw_during_heatingnumber.boiler_wwaltopprioww
1600Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwcomfoffcomfort switch offuint (>=15<=65)Ctruenumber.boiler_comfort_switch_offnumber.boiler_wwcomfoff
1601Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwecooffeco switch offuint (>=15<=65)Ctruenumber.boiler_eco_switch_offnumber.boiler_wwecooff
1602Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwecoplusoffeco+ switch offuint (>=48<=63)Ctruenumber.boiler_eco+_switch_offnumber.boiler_wwecoplusoff
1603Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpcircpumpwwcirculation pump available during dhwbooleantrueswitch.boiler_circulation_pump_available_during_dhwswitch.boiler_hpcircpumpww
1604Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
1605Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
1606Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
1607Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
1608Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
1609Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
1610Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
1611Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
1612Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
1613Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
1614Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
1615Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
1616Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
1617Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
1618Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
1619Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
1620Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
1621Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
1622Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
1623Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
1624Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
1625Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
1626Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
1627Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
1628Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
1629Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
1630Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
1631Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
1632Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
1633Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
1634Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
1635Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
1636Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
1637Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
1638Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
1639Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
1640Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
1641Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
1642Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
1643Geo 5xxboiler173resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
1644Geo 5xxboiler173heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
1645Geo 5xxboiler173tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
1646Geo 5xxboiler173selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
1647Geo 5xxboiler173heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
1648Geo 5xxboiler173outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
1649Geo 5xxboiler173curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
1650Geo 5xxboiler173rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
1651Geo 5xxboiler173switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
1652Geo 5xxboiler173syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
1653Geo 5xxboiler173boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
1654Geo 5xxboiler173exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
1655Geo 5xxboiler173burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
1656Geo 5xxboiler173burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
1657Geo 5xxboiler173flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
1658Geo 5xxboiler173heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
1659Geo 5xxboiler173fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
1660Geo 5xxboiler173ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
1661Geo 5xxboiler173oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
1662Geo 5xxboiler173heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
1663Geo 5xxboiler173heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
1664Geo 5xxboiler173pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
1665Geo 5xxboiler173pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
1666Geo 5xxboiler173pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
1667Geo 5xxboiler173pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
1668Geo 5xxboiler173burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
1669Geo 5xxboiler173burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
1670Geo 5xxboiler173burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
1671Geo 5xxboiler173boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
1672Geo 5xxboiler173boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
1673Geo 5xxboiler173boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
1674Geo 5xxboiler173boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
1675Geo 5xxboiler173setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
1676Geo 5xxboiler173setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
1677Geo 5xxboiler173absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
1678Geo 5xxboiler173selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
1679Geo 5xxboiler173curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
1680Geo 5xxboiler173burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
1681Geo 5xxboiler173burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
1682Geo 5xxboiler173burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
1683Geo 5xxboiler173heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
1684Geo 5xxboiler173heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
1685Geo 5xxboiler173ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
1686Geo 5xxboiler173lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
1687Geo 5xxboiler173servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
1688Geo 5xxboiler173servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
1689Geo 5xxboiler173maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
1690Geo 5xxboiler173maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
1691Geo 5xxboiler173maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
1692Geo 5xxboiler173maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
1693Geo 5xxboiler173emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
1694Geo 5xxboiler173emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
1695Geo 5xxboiler173uptimecontroltotal operating time heattime (>=0<=17476)minutesfalsesensor.boiler_total_operating_time_heatsensor.boiler_uptimecontrol
1696Geo 5xxboiler173uptimecompheatingoperating time compressor heatingtime (>=0<=17476)minutesfalsesensor.boiler_operating_time_compressor_heatingsensor.boiler_uptimecompheating
1697Geo 5xxboiler173uptimecompcoolingoperating time compressor coolingtime (>=0<=17476)minutesfalsesensor.boiler_operating_time_compressor_coolingsensor.boiler_uptimecompcooling
1698Geo 5xxboiler173uptimecompwwoperating time compressor dhwtime (>=0<=17476)minutesfalsesensor.boiler_operating_time_compressor_dhwsensor.boiler_uptimecompww
1699Geo 5xxboiler173uptimecomppooloperating time compressor pooltime (>=0<=17476)minutesfalsesensor.boiler_operating_time_compressor_poolsensor.boiler_uptimecomppool
1700Geo 5xxboiler173totalcompstartstotal compressor control startsulong (>=0<=65533)falsesensor.boiler_total_compressor_control_startssensor.boiler_totalcompstarts
1701Geo 5xxboiler173heatingstartsheating control startsulong (>=0<=65533)falsesensor.boiler_heating_control_startssensor.boiler_heatingstarts
1702Geo 5xxboiler173coolingstartscooling control startsulong (>=0<=65533)falsesensor.boiler_cooling_control_startssensor.boiler_coolingstarts
1703Geo 5xxboiler173wwstarts2control starts2ulong (>=0<=65533)falsesensor.boiler_control_starts2sensor.boiler_wwstarts2
1704Geo 5xxboiler173poolstartspool control startsulong (>=0<=65533)falsesensor.boiler_pool_control_startssensor.boiler_poolstarts
1705Geo 5xxboiler173nrgconstotaltotal energy consumptionulong (>=0<=65533)kWhfalsesensor.boiler_total_energy_consumptionsensor.boiler_nrgconstotal
1706Geo 5xxboiler173nrgconscomptotaltotal energy consumption compressorulong (>=0<=65533)kWhfalsesensor.boiler_total_energy_consumption_compressorsensor.boiler_nrgconscomptotal
1707Geo 5xxboiler173nrgconscompheatingenergy consumption compressor heatingulong (>=0<=65533)kWhfalsesensor.boiler_energy_consumption_compressor_heatingsensor.boiler_nrgconscompheating
1708Geo 5xxboiler173nrgconscompwwenergy consumption compressor dhwulong (>=0<=65533)kWhfalsesensor.boiler_energy_consumption_compressor_dhwsensor.boiler_nrgconscompww
1709Geo 5xxboiler173nrgconscompcoolingenergy consumption compressor coolingulong (>=0<=65533)kWhfalsesensor.boiler_energy_consumption_compressor_coolingsensor.boiler_nrgconscompcooling
1710Geo 5xxboiler173nrgconscomppoolenergy consumption compressor poolulong (>=0<=65533)kWhfalsesensor.boiler_energy_consumption_compressor_poolsensor.boiler_nrgconscomppool
1711Geo 5xxboiler173auxelecheatnrgconstotaltotal aux elec. heater energy consumptionulong (>=0<=65533)kWhfalsesensor.boiler_total_aux_elec._heater_energy_consumptionsensor.boiler_auxelecheatnrgconstotal
1712Geo 5xxboiler173auxelecheatnrgconsheatingaux elec. heater energy consumption heatingulong (>=0<=65533)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_heatingsensor.boiler_auxelecheatnrgconsheating
1713Geo 5xxboiler173auxelecheatnrgconswwaux elec. heater energy consumption dhwulong (>=0<=65533)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_dhwsensor.boiler_auxelecheatnrgconsww
1714Geo 5xxboiler173auxelecheatnrgconspoolaux elec. heater energy consumption poolulong (>=0<=65533)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_poolsensor.boiler_auxelecheatnrgconspool
1715Geo 5xxboiler173nrgsupptotaltotal energy suppliedulong (>=0<=65533)kWhfalsesensor.boiler_total_energy_suppliedsensor.boiler_nrgsupptotal
1716Geo 5xxboiler173nrgsuppheatingtotal energy supplied heatingulong (>=0<=65533)kWhfalsesensor.boiler_total_energy_supplied_heatingsensor.boiler_nrgsuppheating
1717Geo 5xxboiler173nrgsuppwwtotal energy warm supplied dhwulong (>=0<=65533)kWhfalsesensor.boiler_total_energy_warm_supplied_dhwsensor.boiler_nrgsuppww
1718Geo 5xxboiler173nrgsuppcoolingtotal energy supplied coolingulong (>=0<=65533)kWhfalsesensor.boiler_total_energy_supplied_coolingsensor.boiler_nrgsuppcooling
1719Geo 5xxboiler173nrgsupppooltotal energy supplied poolulong (>=0<=65533)kWhfalsesensor.boiler_total_energy_supplied_poolsensor.boiler_nrgsupppool
1720Geo 5xxboiler173hppowercompressor power outputuint (>=0<=25)kWfalsesensor.boiler_compressor_power_outputsensor.boiler_hppower
1721Geo 5xxboiler173hpcomponhp compressorbooleanfalsebinary_sensor.boiler_hp_compressorbinary_sensor.boiler_hpcompon
1722Geo 5xxboiler173hpactivitycompressor activityenum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost]falsesensor.boiler_compressor_activitysensor.boiler_hpactivity
1723Geo 5xxboiler173hpheatingonhp heatingbooleanfalsebinary_sensor.boiler_hp_heatingbinary_sensor.boiler_hpheatingon
1724Geo 5xxboiler173hpcoolingonhp coolingbooleanfalsebinary_sensor.boiler_hp_coolingbinary_sensor.boiler_hpcoolingon
1725Geo 5xxboiler173hpwwonhp dhwbooleanfalsebinary_sensor.boiler_hp_dhwbinary_sensor.boiler_hpwwon
1726Geo 5xxboiler173hppoolonhp poolbooleanfalsebinary_sensor.boiler_hp_poolbinary_sensor.boiler_hppoolon
1727Geo 5xxboiler173hpbrinepumpspdbrine pump speeduint (>=0<=100)%falsesensor.boiler_brine_pump_speedsensor.boiler_hpbrinepumpspd
1728Geo 5xxboiler173hpswitchvalveswitch valvebooleanfalsebinary_sensor.boiler_switch_valvebinary_sensor.boiler_hpswitchvalve
1729Geo 5xxboiler173hpcompspdcompressor speeduint (>=0<=100)%falsesensor.boiler_compressor_speedsensor.boiler_hpcompspd
1730Geo 5xxboiler173hpcircspdcirculation pump speeduint (>=0<=100)%falsesensor.boiler_circulation_pump_speedsensor.boiler_hpcircspd
1731Geo 5xxboiler173hpbrineinbrine in/evaporatorshort (>=-3199<=3199)Cfalsesensor.boiler_brine_in/evaporatorsensor.boiler_hpbrinein
1732Geo 5xxboiler173hpbrineoutbrine out/condensershort (>=-3199<=3199)Cfalsesensor.boiler_brine_out/condensersensor.boiler_hpbrineout
1733Geo 5xxboiler173hptc0heat carrier return (TC0)short (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_return_(TC0)sensor.boiler_hptc0
1734Geo 5xxboiler173hptc1heat carrier forward (TC1)short (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_forward_(TC1)sensor.boiler_hptc1
1735Geo 5xxboiler173hptc3condenser temperature (TC3)short (>=-3199<=3199)Cfalsesensor.boiler_condenser_temperature_(TC3)sensor.boiler_hptc3
1736Geo 5xxboiler173hptr1compressor temperature (TR1)short (>=-3199<=3199)Cfalsesensor.boiler_compressor_temperature_(TR1)sensor.boiler_hptr1
1737Geo 5xxboiler173hptr3refrigerant temperature liquid side (condenser output) (TR3)short (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3)sensor.boiler_hptr3
1738Geo 5xxboiler173hptr4evaporator inlet temperature (TR4)short (>=-3199<=3199)Cfalsesensor.boiler_evaporator_inlet_temperature_(TR4)sensor.boiler_hptr4
1739Geo 5xxboiler173hptr5compressor inlet temperature (TR5)short (>=-3199<=3199)Cfalsesensor.boiler_compressor_inlet_temperature_(TR5)sensor.boiler_hptr5
1740Geo 5xxboiler173hptr6compressor outlet temperature (TR6)short (>=-3199<=3199)Cfalsesensor.boiler_compressor_outlet_temperature_(TR6)sensor.boiler_hptr6
1741Geo 5xxboiler173hptr7refrigerant temperature gas side (condenser input) (TR7)short (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7)sensor.boiler_hptr7
1742Geo 5xxboiler173hptl2air inlet temperature (TL2)short (>=-3199<=3199)Cfalsesensor.boiler_air_inlet_temperature_(TL2)sensor.boiler_hptl2
1743Geo 5xxboiler173hppl1low pressure side temperature (PL1)short (>=-3199<=3199)Cfalsesensor.boiler_low_pressure_side_temperature_(PL1)sensor.boiler_hppl1
1744Geo 5xxboiler173hpph1high pressure side temperature (PH1)short (>=-3199<=3199)Cfalsesensor.boiler_high_pressure_side_temperature_(PH1)sensor.boiler_hpph1
1745Geo 5xxboiler173poolsettemppool set temperatureuint (>=0<=127)Ctruenumber.boiler_pool_set_temperaturenumber.boiler_poolsettemp
1746Geo 5xxboiler173hpin1optinput 1 optionsstringtruesensor.boiler_input_1_optionssensor.boiler_hpin1opt
1747Geo 5xxboiler173hpin2optinput 2 optionsstringtruesensor.boiler_input_2_optionssensor.boiler_hpin2opt
1748Geo 5xxboiler173hpin3optinput 3 optionsstringtruesensor.boiler_input_3_optionssensor.boiler_hpin3opt
1749Geo 5xxboiler173hpin4optinput 4 optionsstringtruesensor.boiler_input_4_optionssensor.boiler_hpin4opt
1750Geo 5xxboiler173maxheatcompheat limit compressorenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_compressorselect.boiler_maxheatcomp
1751Geo 5xxboiler173maxheatheatheat limit heatingenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_heatingselect.boiler_maxheatheat
1752Geo 5xxboiler173maxheatdhwheat limit dhwenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_dhwselect.boiler_maxheatdhw
1753Geo 5xxboiler173mandefrostmanual defrostbooleantrueswitch.boiler_manual_defrostswitch.boiler_mandefrost
1754Geo 5xxboiler173pvcoolingCooling only with PVbooleantrueswitch.boiler_Cooling_only_with_PVswitch.boiler_pvcooling
1755Geo 5xxboiler173auxheateronlyaux heater onlybooleantrueswitch.boiler_aux_heater_onlyswitch.boiler_auxheateronly
1756Geo 5xxboiler173auxheateroffdisable aux heaterbooleantrueswitch.boiler_disable_aux_heaterswitch.boiler_auxheateroff
1757Geo 5xxboiler173auxheaterstatusaux heater statusbooleanfalsebinary_sensor.boiler_aux_heater_statusbinary_sensor.boiler_auxheaterstatus
1758Geo 5xxboiler173auxheaterdelayaux heater on delayushort (>=10<=1000)K*mintruenumber.boiler_aux_heater_on_delaynumber.boiler_auxheaterdelay
1759Geo 5xxboiler173auxmaxlimitaux heater max limituint (>=0<=10)Ktruenumber.boiler_aux_heater_max_limitnumber.boiler_auxmaxlimit
1760Geo 5xxboiler173auxlimitstartaux heater limit startuint (>=0<=10)Ktruenumber.boiler_aux_heater_limit_startnumber.boiler_auxlimitstart
1761Geo 5xxboiler173auxheatrmodeaux heater modeenum [eco\|comfort]trueselect.boiler_aux_heater_modeselect.boiler_auxheatrmode
1762Geo 5xxboiler173hphystheaton/off hyst heatushort (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_heatnumber.boiler_hphystheat
1763Geo 5xxboiler173hphystcoolon/off hyst coolushort (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_coolnumber.boiler_hphystcool
1764Geo 5xxboiler173hphystpoolon/off hyst poolushort (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_poolnumber.boiler_hphystpool
1765Geo 5xxboiler173silentmodesilent modeenum [off\|auto\|on]trueselect.boiler_silent_modeselect.boiler_silentmode
1766Geo 5xxboiler173silentfromsilent mode fromuint (>=0<=3810)minutestruenumber.boiler_silent_mode_fromnumber.boiler_silentfrom
1767Geo 5xxboiler173silenttosilent mode touint (>=0<=3810)minutestruenumber.boiler_silent_mode_tonumber.boiler_silentto
1768Geo 5xxboiler173mintempsilentmin outside temp for silent modeint (>=-126<=126)Ctruenumber.boiler_min_outside_temp_for_silent_modenumber.boiler_mintempsilent
1769Geo 5xxboiler173tempparmodeoutside temp parallel modeint (>=-126<=126)Ctruenumber.boiler_outside_temp_parallel_modenumber.boiler_tempparmode
1770Geo 5xxboiler173auxheatmixaux heater mixing valveint (>=-100<=100)%falsesensor.boiler_aux_heater_mixing_valvesensor.boiler_auxheatmix
1771Geo 5xxboiler173tempdiffheattemp diff TC3/TC0 heatuint (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_heatnumber.boiler_tempdiffheat
1772Geo 5xxboiler173tempdiffcooltemp diff TC3/TC0 cooluint (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_coolnumber.boiler_tempdiffcool
1773Geo 5xxboiler173vpcoolingvalve/pump coolingbooleantrueswitch.boiler_valve/pump_coolingswitch.boiler_vpcooling
1774Geo 5xxboiler173heatcableheating cablebooleantrueswitch.boiler_heating_cableswitch.boiler_heatcable
1775Geo 5xxboiler173vc0valveVC0 valvebooleantrueswitch.boiler_VC0_valveswitch.boiler_vc0valve
1776Geo 5xxboiler173primepumpprimary heatpumpbooleantrueswitch.boiler_primary_heatpumpswitch.boiler_primepump
1777Geo 5xxboiler173primepumpmodprimary heatpump modulationuint (>=0<=100)%truenumber.boiler_primary_heatpump_modulationnumber.boiler_primepumpmod
1778Geo 5xxboiler173hp3way3-way valvebooleantrueswitch.boiler_3-way_valveswitch.boiler_hp3way
1779Geo 5xxboiler173elheatstep1el. heater step 1booleantrueswitch.boiler_el._heater_step_1switch.boiler_elheatstep1
1780Geo 5xxboiler173elheatstep2el. heater step 2booleantrueswitch.boiler_el._heater_step_2switch.boiler_elheatstep2
1781Geo 5xxboiler173elheatstep3el. heater step 3booleantrueswitch.boiler_el._heater_step_3switch.boiler_elheatstep3
1782Geo 5xxboiler173wwalternatingopalternating operationbooleantrueswitch.boiler_alternating_operationswitch.boiler_wwalternatingop
1783Geo 5xxboiler173wwaltopprioheatprioritise heating during dhwuint (>=20<=120)minutestruenumber.boiler_prioritise_heating_during_dhwnumber.boiler_wwaltopprioheat
1784Geo 5xxboiler173wwaltoppriowwprioritise dhw during heatinguint (>=30<=120)minutestruenumber.boiler_prioritise_dhw_during_heatingnumber.boiler_wwaltopprioww
1785Geo 5xxboiler173wwcomfoffcomfort switch offuint (>=15<=65)Ctruenumber.boiler_comfort_switch_offnumber.boiler_wwcomfoff
1786Geo 5xxboiler173wwecooffeco switch offuint (>=15<=65)Ctruenumber.boiler_eco_switch_offnumber.boiler_wwecooff
1787Geo 5xxboiler173wwecoplusoffeco+ switch offuint (>=48<=63)Ctruenumber.boiler_eco+_switch_offnumber.boiler_wwecoplusoff
1788Geo 5xxboiler173hpcircpumpwwcirculation pump available during dhwbooleantrueswitch.boiler_circulation_pump_available_during_dhwswitch.boiler_hpcircpumpww
1789Geo 5xxboiler173wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
1790Geo 5xxboiler173wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
1791Geo 5xxboiler173wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
1792Geo 5xxboiler173wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
1793Geo 5xxboiler173wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
1794Geo 5xxboiler173wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
1795Geo 5xxboiler173wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
1796Geo 5xxboiler173wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
1797Geo 5xxboiler173wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
1798Geo 5xxboiler173wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
1799Geo 5xxboiler173wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
1800Geo 5xxboiler173wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
1801Geo 5xxboiler173wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
1802Geo 5xxboiler173wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
1803Geo 5xxboiler173wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
1804Geo 5xxboiler173wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
1805Geo 5xxboiler173wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
1806Geo 5xxboiler173wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
1807Geo 5xxboiler173wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
1808Geo 5xxboiler173wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
1809Geo 5xxboiler173wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
1810Geo 5xxboiler173wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
1811Geo 5xxboiler173wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
1812Geo 5xxboiler173wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
1813Geo 5xxboiler173wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
1814Geo 5xxboiler173wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
1815Geo 5xxboiler173wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
1816Geo 5xxboiler173wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
1817Geo 5xxboiler173wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
1818Geo 5xxboiler173wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
1819Geo 5xxboiler173wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
1820Geo 5xxboiler173wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
1821Geo 5xxboiler173wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
1822Geo 5xxboiler173ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
1823Geo 5xxboiler173wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
1824Geo 5xxboiler173wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
1825Geo 5xxboiler173wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
1826Geo 5xxboiler173wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
1827Geo 5xxboiler173wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
1828Condens 5000i/Greenstar 8000/GC9800IWboiler195resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
1829Condens 5000i/Greenstar 8000/GC9800IWboiler195heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
1830Condens 5000i/Greenstar 8000/GC9800IWboiler195tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
1831Condens 5000i/Greenstar 8000/GC9800IWboiler195selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
1832Condens 5000i/Greenstar 8000/GC9800IWboiler195heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
1833Condens 5000i/Greenstar 8000/GC9800IWboiler195outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
1834Condens 5000i/Greenstar 8000/GC9800IWboiler195curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
1835Condens 5000i/Greenstar 8000/GC9800IWboiler195rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
1836Condens 5000i/Greenstar 8000/GC9800IWboiler195switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
1837Condens 5000i/Greenstar 8000/GC9800IWboiler195syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
1838Condens 5000i/Greenstar 8000/GC9800IWboiler195boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
1839Condens 5000i/Greenstar 8000/GC9800IWboiler195exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
1840Condens 5000i/Greenstar 8000/GC9800IWboiler195burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
1841Condens 5000i/Greenstar 8000/GC9800IWboiler195burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
1842Condens 5000i/Greenstar 8000/GC9800IWboiler195flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
1843Condens 5000i/Greenstar 8000/GC9800IWboiler195heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
1844Condens 5000i/Greenstar 8000/GC9800IWboiler195fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
1845Condens 5000i/Greenstar 8000/GC9800IWboiler195ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
1846Condens 5000i/Greenstar 8000/GC9800IWboiler195oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
1847Condens 5000i/Greenstar 8000/GC9800IWboiler195heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
1848Condens 5000i/Greenstar 8000/GC9800IWboiler195heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
1849Condens 5000i/Greenstar 8000/GC9800IWboiler195pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
1850Condens 5000i/Greenstar 8000/GC9800IWboiler195pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
1851Condens 5000i/Greenstar 8000/GC9800IWboiler195pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
1852Condens 5000i/Greenstar 8000/GC9800IWboiler195pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
1853Condens 5000i/Greenstar 8000/GC9800IWboiler195burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
1854Condens 5000i/Greenstar 8000/GC9800IWboiler195burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
1855Condens 5000i/Greenstar 8000/GC9800IWboiler195burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
1856Condens 5000i/Greenstar 8000/GC9800IWboiler195boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
1857Condens 5000i/Greenstar 8000/GC9800IWboiler195boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
1858Condens 5000i/Greenstar 8000/GC9800IWboiler195boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
1859Condens 5000i/Greenstar 8000/GC9800IWboiler195boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
1860Condens 5000i/Greenstar 8000/GC9800IWboiler195setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
1861Condens 5000i/Greenstar 8000/GC9800IWboiler195setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
1862Condens 5000i/Greenstar 8000/GC9800IWboiler195absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
1863Condens 5000i/Greenstar 8000/GC9800IWboiler195selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
1864Condens 5000i/Greenstar 8000/GC9800IWboiler195curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
1865Condens 5000i/Greenstar 8000/GC9800IWboiler195burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
1866Condens 5000i/Greenstar 8000/GC9800IWboiler195burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
1867Condens 5000i/Greenstar 8000/GC9800IWboiler195burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
1868Condens 5000i/Greenstar 8000/GC9800IWboiler195heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
1869Condens 5000i/Greenstar 8000/GC9800IWboiler195heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
1870Condens 5000i/Greenstar 8000/GC9800IWboiler195ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
1871Condens 5000i/Greenstar 8000/GC9800IWboiler195lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
1872Condens 5000i/Greenstar 8000/GC9800IWboiler195servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
1873Condens 5000i/Greenstar 8000/GC9800IWboiler195servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
1874Condens 5000i/Greenstar 8000/GC9800IWboiler195maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
1875Condens 5000i/Greenstar 8000/GC9800IWboiler195maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
1876Condens 5000i/Greenstar 8000/GC9800IWboiler195maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
1877Condens 5000i/Greenstar 8000/GC9800IWboiler195maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
1878Condens 5000i/Greenstar 8000/GC9800IWboiler195emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
1879Condens 5000i/Greenstar 8000/GC9800IWboiler195emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
1880Condens 5000i/Greenstar 8000/GC9800IWboiler195wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
1881Condens 5000i/Greenstar 8000/GC9800IWboiler195wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
1882Condens 5000i/Greenstar 8000/GC9800IWboiler195wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
1883Condens 5000i/Greenstar 8000/GC9800IWboiler195wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
1884Condens 5000i/Greenstar 8000/GC9800IWboiler195wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
1885Condens 5000i/Greenstar 8000/GC9800IWboiler195wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
1886Condens 5000i/Greenstar 8000/GC9800IWboiler195wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
1887Condens 5000i/Greenstar 8000/GC9800IWboiler195wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
1888Condens 5000i/Greenstar 8000/GC9800IWboiler195wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
1889Condens 5000i/Greenstar 8000/GC9800IWboiler195wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
1890Condens 5000i/Greenstar 8000/GC9800IWboiler195wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
1891Condens 5000i/Greenstar 8000/GC9800IWboiler195wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
1892Condens 5000i/Greenstar 8000/GC9800IWboiler195wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
1893Condens 5000i/Greenstar 8000/GC9800IWboiler195wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
1894Condens 5000i/Greenstar 8000/GC9800IWboiler195wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
1895Condens 5000i/Greenstar 8000/GC9800IWboiler195wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
1896Condens 5000i/Greenstar 8000/GC9800IWboiler195wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
1897Condens 5000i/Greenstar 8000/GC9800IWboiler195wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
1898Condens 5000i/Greenstar 8000/GC9800IWboiler195wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
1899Condens 5000i/Greenstar 8000/GC9800IWboiler195wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
1900Condens 5000i/Greenstar 8000/GC9800IWboiler195wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
1901Condens 5000i/Greenstar 8000/GC9800IWboiler195wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
1902Condens 5000i/Greenstar 8000/GC9800IWboiler195wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
1903Condens 5000i/Greenstar 8000/GC9800IWboiler195wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
1904Condens 5000i/Greenstar 8000/GC9800IWboiler195wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
1905Condens 5000i/Greenstar 8000/GC9800IWboiler195wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
1906Condens 5000i/Greenstar 8000/GC9800IWboiler195wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
1907Condens 5000i/Greenstar 8000/GC9800IWboiler195wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
1908Condens 5000i/Greenstar 8000/GC9800IWboiler195wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
1909Condens 5000i/Greenstar 8000/GC9800IWboiler195wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
1910Condens 5000i/Greenstar 8000/GC9800IWboiler195wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
1911Condens 5000i/Greenstar 8000/GC9800IWboiler195wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
1912Condens 5000i/Greenstar 8000/GC9800IWboiler195wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
1913Condens 5000i/Greenstar 8000/GC9800IWboiler195ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
1914Condens 5000i/Greenstar 8000/GC9800IWboiler195wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
1915Condens 5000i/Greenstar 8000/GC9800IWboiler195wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
1916Condens 5000i/Greenstar 8000/GC9800IWboiler195wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
1917Condens 5000i/Greenstar 8000/GC9800IWboiler195wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
1918Condens 5000i/Greenstar 8000/GC9800IWboiler195wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
1919Logamax U122/Cerapurboiler203resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
1920Logamax U122/Cerapurboiler203heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
1921Logamax U122/Cerapurboiler203tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
1922Logamax U122/Cerapurboiler203selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
1923Logamax U122/Cerapurboiler203heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
1924Logamax U122/Cerapurboiler203outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
1925Logamax U122/Cerapurboiler203curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
1926Logamax U122/Cerapurboiler203rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
1927Logamax U122/Cerapurboiler203switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
1928Logamax U122/Cerapurboiler203syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
1929Logamax U122/Cerapurboiler203boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
1930Logamax U122/Cerapurboiler203exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
1931Logamax U122/Cerapurboiler203burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
1932Logamax U122/Cerapurboiler203burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
1933Logamax U122/Cerapurboiler203flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
1934Logamax U122/Cerapurboiler203heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
1935Logamax U122/Cerapurboiler203fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
1936Logamax U122/Cerapurboiler203ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
1937Logamax U122/Cerapurboiler203oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
1938Logamax U122/Cerapurboiler203heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
1939Logamax U122/Cerapurboiler203heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
1940Logamax U122/Cerapurboiler203pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
1941Logamax U122/Cerapurboiler203pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
1942Logamax U122/Cerapurboiler203pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
1943Logamax U122/Cerapurboiler203pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
1944Logamax U122/Cerapurboiler203burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
1945Logamax U122/Cerapurboiler203burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
1946Logamax U122/Cerapurboiler203burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
1947Logamax U122/Cerapurboiler203boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
1948Logamax U122/Cerapurboiler203boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
1949Logamax U122/Cerapurboiler203boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
1950Logamax U122/Cerapurboiler203boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
1951Logamax U122/Cerapurboiler203setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
1952Logamax U122/Cerapurboiler203setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
1953Logamax U122/Cerapurboiler203absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
1954Logamax U122/Cerapurboiler203selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
1955Logamax U122/Cerapurboiler203curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
1956Logamax U122/Cerapurboiler203burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
1957Logamax U122/Cerapurboiler203burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
1958Logamax U122/Cerapurboiler203burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
1959Logamax U122/Cerapurboiler203heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
1960Logamax U122/Cerapurboiler203heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
1961Logamax U122/Cerapurboiler203ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
1962Logamax U122/Cerapurboiler203lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
1963Logamax U122/Cerapurboiler203servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
1964Logamax U122/Cerapurboiler203servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
1965Logamax U122/Cerapurboiler203maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
1966Logamax U122/Cerapurboiler203maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
1967Logamax U122/Cerapurboiler203maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
1968Logamax U122/Cerapurboiler203maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
1969Logamax U122/Cerapurboiler203emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
1970Logamax U122/Cerapurboiler203emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
1971Logamax U122/Cerapurboiler203wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
1972Logamax U122/Cerapurboiler203wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
1973Logamax U122/Cerapurboiler203wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
1974Logamax U122/Cerapurboiler203wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
1975Logamax U122/Cerapurboiler203wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
1976Logamax U122/Cerapurboiler203wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
1977Logamax U122/Cerapurboiler203wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
1978Logamax U122/Cerapurboiler203wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
1979Logamax U122/Cerapurboiler203wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
1980Logamax U122/Cerapurboiler203wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
1981Logamax U122/Cerapurboiler203wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
1982Logamax U122/Cerapurboiler203wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
1983Logamax U122/Cerapurboiler203wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
1984Logamax U122/Cerapurboiler203wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
1985Logamax U122/Cerapurboiler203wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
1986Logamax U122/Cerapurboiler203wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
1987Logamax U122/Cerapurboiler203wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
1988Logamax U122/Cerapurboiler203wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
1989Logamax U122/Cerapurboiler203wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
1990Logamax U122/Cerapurboiler203wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
1991Logamax U122/Cerapurboiler203wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
1992Logamax U122/Cerapurboiler203wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
1993Logamax U122/Cerapurboiler203wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
1994Logamax U122/Cerapurboiler203wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
1995Logamax U122/Cerapurboiler203wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
1996Logamax U122/Cerapurboiler203wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
1997Logamax U122/Cerapurboiler203wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
1998Logamax U122/Cerapurboiler203wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
1999Logamax U122/Cerapurboiler203wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
2000Logamax U122/Cerapurboiler203wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
2001Logamax U122/Cerapurboiler203wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
2002Logamax U122/Cerapurboiler203wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
2003Logamax U122/Cerapurboiler203wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
2004Logamax U122/Cerapurboiler203ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
2005Logamax U122/Cerapurboiler203wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
2006Logamax U122/Cerapurboiler203wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
2007Logamax U122/Cerapurboiler203wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
2008Logamax U122/Cerapurboiler203wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
2009Logamax U122/Cerapurboiler203wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
2010Ecomline Excellentboiler206resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
2011Ecomline Excellentboiler206heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
2012Ecomline Excellentboiler206tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
2013Ecomline Excellentboiler206selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
2014Ecomline Excellentboiler206heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
2015Ecomline Excellentboiler206outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
2016Ecomline Excellentboiler206curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
2017Ecomline Excellentboiler206rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
2018Ecomline Excellentboiler206switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
2019Ecomline Excellentboiler206syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
2020Ecomline Excellentboiler206boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
2021Ecomline Excellentboiler206exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
2022Ecomline Excellentboiler206burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
2023Ecomline Excellentboiler206burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
2024Ecomline Excellentboiler206flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
2025Ecomline Excellentboiler206heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
2026Ecomline Excellentboiler206fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
2027Ecomline Excellentboiler206ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
2028Ecomline Excellentboiler206oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
2029Ecomline Excellentboiler206heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
2030Ecomline Excellentboiler206heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
2031Ecomline Excellentboiler206pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
2032Ecomline Excellentboiler206pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
2033Ecomline Excellentboiler206pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
2034Ecomline Excellentboiler206pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
2035Ecomline Excellentboiler206burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
2036Ecomline Excellentboiler206burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
2037Ecomline Excellentboiler206burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
2038Ecomline Excellentboiler206boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
2039Ecomline Excellentboiler206boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
2040Ecomline Excellentboiler206boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
2041Ecomline Excellentboiler206boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
2042Ecomline Excellentboiler206setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
2043Ecomline Excellentboiler206setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
2044Ecomline Excellentboiler206absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
2045Ecomline Excellentboiler206selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
2046Ecomline Excellentboiler206curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
2047Ecomline Excellentboiler206burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
2048Ecomline Excellentboiler206burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
2049Ecomline Excellentboiler206burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
2050Ecomline Excellentboiler206heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
2051Ecomline Excellentboiler206heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
2052Ecomline Excellentboiler206ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
2053Ecomline Excellentboiler206lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
2054Ecomline Excellentboiler206servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
2055Ecomline Excellentboiler206servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
2056Ecomline Excellentboiler206maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
2057Ecomline Excellentboiler206maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
2058Ecomline Excellentboiler206maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
2059Ecomline Excellentboiler206maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
2060Ecomline Excellentboiler206emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
2061Ecomline Excellentboiler206emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
2062Ecomline Excellentboiler206wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
2063Ecomline Excellentboiler206wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
2064Ecomline Excellentboiler206wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
2065Ecomline Excellentboiler206wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
2066Ecomline Excellentboiler206wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
2067Ecomline Excellentboiler206wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
2068Ecomline Excellentboiler206wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
2069Ecomline Excellentboiler206wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
2070Ecomline Excellentboiler206wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
2071Ecomline Excellentboiler206wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
2072Ecomline Excellentboiler206wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
2073Ecomline Excellentboiler206wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
2074Ecomline Excellentboiler206wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
2075Ecomline Excellentboiler206wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
2076Ecomline Excellentboiler206wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
2077Ecomline Excellentboiler206wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
2078Ecomline Excellentboiler206wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
2079Ecomline Excellentboiler206wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
2080Ecomline Excellentboiler206wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
2081Ecomline Excellentboiler206wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
2082Ecomline Excellentboiler206wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
2083Ecomline Excellentboiler206wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
2084Ecomline Excellentboiler206wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
2085Ecomline Excellentboiler206wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
2086Ecomline Excellentboiler206wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
2087Ecomline Excellentboiler206wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
2088Ecomline Excellentboiler206wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
2089Ecomline Excellentboiler206wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
2090Ecomline Excellentboiler206wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
2091Ecomline Excellentboiler206wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
2092Ecomline Excellentboiler206wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
2093Ecomline Excellentboiler206wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
2094Ecomline Excellentboiler206wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
2095Ecomline Excellentboiler206ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
2096Ecomline Excellentboiler206wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
2097Ecomline Excellentboiler206wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
2098Ecomline Excellentboiler206wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
2099Ecomline Excellentboiler206wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
2100Ecomline Excellentboiler206wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
2101Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
2102Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
2103Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
2104Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
2105Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
2106Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
2107Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
2108Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
2109Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
2110Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
2111Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
2112Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
2113Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
2114Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
2115Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
2116Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
2117Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
2118Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
2119Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
2120Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
2121Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
2122Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
2123Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
2124Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
2125Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
2126Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
2127Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
2128Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
2129Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
2130Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
2131Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
2132Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
2133Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
2134Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
2135Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
2136Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
2137Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
2138Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
2139Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
2140Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
2141Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
2142Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
2143Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
2144Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
2145Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
2146Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
2147Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
2148Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
2149Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
2150Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
2151Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
2152Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
2153Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
2154Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
2155Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
2156Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
2157Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
2158Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
2159Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
2160Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
2161Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
2162Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
2163Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
2164Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
2165Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
2166Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
2167Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
2168Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
2169Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
2170Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
2171Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
2172Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
2173Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
2174Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
2175Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
2176Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
2177Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
2178Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
2179Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
2180Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
2181Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
2182Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
2183Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
2184Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
2185Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
2186Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
2187Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
2188Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
2189Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
2190Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
2191Logamax Plus/GB192/Condens GC9000/Greenstar ErPboiler208wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
2192Cascade MC400boiler210resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
2193Cascade MC400boiler210heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
2194Cascade MC400boiler210tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
2195Cascade MC400boiler210selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
2196Cascade MC400boiler210heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
2197Cascade MC400boiler210outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
2198Cascade MC400boiler210curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
2199Cascade MC400boiler210rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
2200Cascade MC400boiler210switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
2201Cascade MC400boiler210syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
2202Cascade MC400boiler210boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
2203Cascade MC400boiler210exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
2204Cascade MC400boiler210burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
2205Cascade MC400boiler210burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
2206Cascade MC400boiler210flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
2207Cascade MC400boiler210heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
2208Cascade MC400boiler210fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
2209Cascade MC400boiler210ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
2210Cascade MC400boiler210oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
2211Cascade MC400boiler210heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
2212Cascade MC400boiler210heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
2213Cascade MC400boiler210pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
2214Cascade MC400boiler210pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
2215Cascade MC400boiler210pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
2216Cascade MC400boiler210pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
2217Cascade MC400boiler210burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
2218Cascade MC400boiler210burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
2219Cascade MC400boiler210burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
2220Cascade MC400boiler210boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
2221Cascade MC400boiler210boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
2222Cascade MC400boiler210boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
2223Cascade MC400boiler210boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
2224Cascade MC400boiler210setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
2225Cascade MC400boiler210setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
2226Cascade MC400boiler210absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
2227Cascade MC400boiler210selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
2228Cascade MC400boiler210curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
2229Cascade MC400boiler210burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
2230Cascade MC400boiler210burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
2231Cascade MC400boiler210burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
2232Cascade MC400boiler210heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
2233Cascade MC400boiler210heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
2234Cascade MC400boiler210ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
2235Cascade MC400boiler210lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
2236Cascade MC400boiler210servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
2237Cascade MC400boiler210servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
2238Cascade MC400boiler210maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
2239Cascade MC400boiler210maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
2240Cascade MC400boiler210maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
2241Cascade MC400boiler210maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
2242Cascade MC400boiler210emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
2243Cascade MC400boiler210emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
2244Cascade MC400boiler210wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
2245Cascade MC400boiler210wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
2246Cascade MC400boiler210wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
2247Cascade MC400boiler210wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
2248Cascade MC400boiler210wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
2249Cascade MC400boiler210wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
2250Cascade MC400boiler210wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
2251Cascade MC400boiler210wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
2252Cascade MC400boiler210wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
2253Cascade MC400boiler210wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
2254Cascade MC400boiler210wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
2255Cascade MC400boiler210wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
2256Cascade MC400boiler210wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
2257Cascade MC400boiler210wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
2258Cascade MC400boiler210wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
2259Cascade MC400boiler210wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
2260Cascade MC400boiler210wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
2261Cascade MC400boiler210wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
2262Cascade MC400boiler210wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
2263Cascade MC400boiler210wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
2264Cascade MC400boiler210wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
2265Cascade MC400boiler210wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
2266Cascade MC400boiler210wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
2267Cascade MC400boiler210wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
2268Cascade MC400boiler210wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
2269Cascade MC400boiler210wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
2270Cascade MC400boiler210wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
2271Cascade MC400boiler210wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
2272Cascade MC400boiler210wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
2273Cascade MC400boiler210wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
2274Cascade MC400boiler210wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
2275Cascade MC400boiler210wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
2276Cascade MC400boiler210wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
2277Cascade MC400boiler210ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
2278Cascade MC400boiler210wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
2279Cascade MC400boiler210wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
2280Cascade MC400boiler210wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
2281Cascade MC400boiler210wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
2282Cascade MC400boiler210wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
2283EasyControl Adapterboiler211resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
2284EasyControl Adapterboiler211heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
2285EasyControl Adapterboiler211tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
2286EasyControl Adapterboiler211selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
2287EasyControl Adapterboiler211heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
2288EasyControl Adapterboiler211outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
2289EasyControl Adapterboiler211curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
2290EasyControl Adapterboiler211rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
2291EasyControl Adapterboiler211switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
2292EasyControl Adapterboiler211syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
2293EasyControl Adapterboiler211boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
2294EasyControl Adapterboiler211exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
2295EasyControl Adapterboiler211burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
2296EasyControl Adapterboiler211burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
2297EasyControl Adapterboiler211flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
2298EasyControl Adapterboiler211heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
2299EasyControl Adapterboiler211fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
2300EasyControl Adapterboiler211ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
2301EasyControl Adapterboiler211oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
2302EasyControl Adapterboiler211heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
2303EasyControl Adapterboiler211heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
2304EasyControl Adapterboiler211pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
2305EasyControl Adapterboiler211pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
2306EasyControl Adapterboiler211pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
2307EasyControl Adapterboiler211pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
2308EasyControl Adapterboiler211burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
2309EasyControl Adapterboiler211burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
2310EasyControl Adapterboiler211burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
2311EasyControl Adapterboiler211boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
2312EasyControl Adapterboiler211boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
2313EasyControl Adapterboiler211boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
2314EasyControl Adapterboiler211boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
2315EasyControl Adapterboiler211setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
2316EasyControl Adapterboiler211setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
2317EasyControl Adapterboiler211absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
2318EasyControl Adapterboiler211selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
2319EasyControl Adapterboiler211curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
2320EasyControl Adapterboiler211burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
2321EasyControl Adapterboiler211burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
2322EasyControl Adapterboiler211burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
2323EasyControl Adapterboiler211heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
2324EasyControl Adapterboiler211heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
2325EasyControl Adapterboiler211ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
2326EasyControl Adapterboiler211lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
2327EasyControl Adapterboiler211servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
2328EasyControl Adapterboiler211servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
2329EasyControl Adapterboiler211maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
2330EasyControl Adapterboiler211maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
2331EasyControl Adapterboiler211maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
2332EasyControl Adapterboiler211maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
2333EasyControl Adapterboiler211emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
2334EasyControl Adapterboiler211emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
2335EasyControl Adapterboiler211wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
2336EasyControl Adapterboiler211wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
2337EasyControl Adapterboiler211wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
2338EasyControl Adapterboiler211wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
2339EasyControl Adapterboiler211wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
2340EasyControl Adapterboiler211wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
2341EasyControl Adapterboiler211wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
2342EasyControl Adapterboiler211wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
2343EasyControl Adapterboiler211wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
2344EasyControl Adapterboiler211wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
2345EasyControl Adapterboiler211wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
2346EasyControl Adapterboiler211wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
2347EasyControl Adapterboiler211wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
2348EasyControl Adapterboiler211wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
2349EasyControl Adapterboiler211wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
2350EasyControl Adapterboiler211wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
2351EasyControl Adapterboiler211wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
2352EasyControl Adapterboiler211wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
2353EasyControl Adapterboiler211wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
2354EasyControl Adapterboiler211wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
2355EasyControl Adapterboiler211wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
2356EasyControl Adapterboiler211wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
2357EasyControl Adapterboiler211wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
2358EasyControl Adapterboiler211wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
2359EasyControl Adapterboiler211wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
2360EasyControl Adapterboiler211wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
2361EasyControl Adapterboiler211wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
2362EasyControl Adapterboiler211wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
2363EasyControl Adapterboiler211wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
2364EasyControl Adapterboiler211wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
2365EasyControl Adapterboiler211wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
2366EasyControl Adapterboiler211wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
2367EasyControl Adapterboiler211wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
2368EasyControl Adapterboiler211ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
2369EasyControl Adapterboiler211wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
2370EasyControl Adapterboiler211wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
2371EasyControl Adapterboiler211wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
2372EasyControl Adapterboiler211wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
2373EasyControl Adapterboiler211wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
2374Greenstar HIUboiler219keepwarmtempkeep warm temperatureuint (>=0<=254)Ctruenumber.boiler_keep_warm_temperaturenumber.boiler_keepwarmtemp
2375Greenstar HIUboiler219setreturntempset temp returnuint (>=0<=254)Ctruenumber.boiler_set_temp_returnnumber.boiler_setreturntemp
2376Greenstar HIUboiler219cwflowratecold water flow rateushort (>=0<=31999)l/minfalsesensor.boiler_cold_water_flow_ratesensor.boiler_cwflowrate
2377Greenstar HIUboiler219netflowtempheat network flow tempushort (>=0<=31999)Cfalsesensor.boiler_heat_network_flow_tempsensor.boiler_netflowtemp
2378Greenstar HIUboiler219resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
2379Greenstar HIUboiler219heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
2380Greenstar HIUboiler219tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
2381Greenstar HIUboiler219selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
2382Greenstar HIUboiler219heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
2383Greenstar HIUboiler219outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
2384Greenstar HIUboiler219curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
2385Greenstar HIUboiler219rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
2386Greenstar HIUboiler219switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
2387Greenstar HIUboiler219syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
2388Greenstar HIUboiler219boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
2389Greenstar HIUboiler219exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
2390Greenstar HIUboiler219burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
2391Greenstar HIUboiler219burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
2392Greenstar HIUboiler219flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
2393Greenstar HIUboiler219heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
2394Greenstar HIUboiler219fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
2395Greenstar HIUboiler219ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
2396Greenstar HIUboiler219oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
2397Greenstar HIUboiler219heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
2398Greenstar HIUboiler219heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
2399Greenstar HIUboiler219pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
2400Greenstar HIUboiler219pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
2401Greenstar HIUboiler219pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
2402Greenstar HIUboiler219pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
2403Greenstar HIUboiler219burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
2404Greenstar HIUboiler219burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
2405Greenstar HIUboiler219burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
2406Greenstar HIUboiler219boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
2407Greenstar HIUboiler219boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
2408Greenstar HIUboiler219boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
2409Greenstar HIUboiler219boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
2410Greenstar HIUboiler219setflowtempset flow temperatureuint (>=0<=254)Cfalsesensor.boiler_set_flow_temperaturesensor.boiler_setflowtemp
2411Greenstar HIUboiler219setburnpowburner set poweruint (>=0<=100)%falsesensor.boiler_burner_set_powersensor.boiler_setburnpow
2412Greenstar HIUboiler219absburnpowburner current power (absolute)uint (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow
2413Greenstar HIUboiler219selburnpowburner selected max poweruint (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow
2414Greenstar HIUboiler219curburnpowburner current poweruint (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow
2415Greenstar HIUboiler219burnstartsburner startsulong (>=0<=65533)falsesensor.boiler_burner_startssensor.boiler_burnstarts
2416Greenstar HIUboiler219burnworkmintotal burner operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin
2417Greenstar HIUboiler219burn2workminburner stage 2 operating timetime (>=0<=65533)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin
2418Greenstar HIUboiler219heatworkmintotal heat operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin
2419Greenstar HIUboiler219heatstartsburner starts heatingulong (>=0<=65533)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts
2420Greenstar HIUboiler219ubauptimetotal UBA operating timetime (>=0<=65533)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime
2421Greenstar HIUboiler219lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode
2422Greenstar HIUboiler219servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode
2423Greenstar HIUboiler219servicecodenumberservice code numberushort (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber
2424Greenstar HIUboiler219maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage
2425Greenstar HIUboiler219maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance
2426Greenstar HIUboiler219maintenancetimetime to next maintenanceushort (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime
2427Greenstar HIUboiler219maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate
2428Greenstar HIUboiler219emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops
2429Greenstar HIUboiler219emergencytempemergency temperatureuint (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp
2430Greenstar HIUboiler219wwtapactivatedturn on/offbooleantrueswitch.boiler_turn_on/offswitch.boiler_wwtapactivated
2431Greenstar HIUboiler219wwsettempset temperatureuint (>=0<=254)Cfalsesensor.boiler_set_temperaturesensor.boiler_wwsettemp
2432Greenstar HIUboiler219wwseltempselected temperatureuint (>=0<=254)Ctruenumber.boiler_selected_temperaturenumber.boiler_wwseltemp
2433Greenstar HIUboiler219wwseltemplowselected lower temperatureuint (>=0<=254)Ctruenumber.boiler_selected_lower_temperaturenumber.boiler_wwseltemplow
2434Greenstar HIUboiler219wwseltempoffselected temperature for offuint (>=0<=254)Cfalsesensor.boiler_selected_temperature_for_offsensor.boiler_wwseltempoff
2435Greenstar HIUboiler219wwseltempsinglesingle charge temperatureuint (>=0<=254)Ctruenumber.boiler_single_charge_temperaturenumber.boiler_wwseltempsingle
2436Greenstar HIUboiler219wwsolartempsolar boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_solar_boiler_temperaturesensor.boiler_wwsolartemp
2437Greenstar HIUboiler219wwtypetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_typesensor.boiler_wwtype
2438Greenstar HIUboiler219wwcomfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_comfortselect.boiler_wwcomfort
2439Greenstar HIUboiler219wwcomfort1comfort modeenum [high comfort\|eco]trueselect.boiler_comfort_modeselect.boiler_wwcomfort1
2440Greenstar HIUboiler219wwflowtempoffsetflow temperature offsetuint (>=0<=100)Ctruenumber.boiler_flow_temperature_offsetnumber.boiler_wwflowtempoffset
2441Greenstar HIUboiler219wwchargeoptimizationcharge optimizationbooleantrueswitch.boiler_charge_optimizationswitch.boiler_wwchargeoptimization
2442Greenstar HIUboiler219wwmaxpowermax poweruint (>=0<=254)%truenumber.boiler_max_powernumber.boiler_wwmaxpower
2443Greenstar HIUboiler219wwmaxtempmaximum temperatureuint (>=0<=70)Ctruenumber.boiler_maximum_temperaturenumber.boiler_wwmaxtemp
2444Greenstar HIUboiler219wwcircpumpcirculation pump availablebooleantrueswitch.boiler_circulation_pump_availableswitch.boiler_wwcircpump
2445Greenstar HIUboiler219wwchargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_charging_typesensor.boiler_wwchargetype
2446Greenstar HIUboiler219wwhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_wwhyston
2447Greenstar HIUboiler219wwhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_wwhystoff
2448Greenstar HIUboiler219wwdisinfectiontempdisinfection temperatureuint (>=0<=254)Ctruenumber.boiler_disinfection_temperaturenumber.boiler_wwdisinfectiontemp
2449Greenstar HIUboiler219wwcircmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_circulation_pump_modeselect.boiler_wwcircmode
2450Greenstar HIUboiler219wwcirccirculation activebooleantrueswitch.boiler_circulation_activeswitch.boiler_wwcirc
2451Greenstar HIUboiler219wwcurtempcurrent intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_intern_temperaturesensor.boiler_wwcurtemp
2452Greenstar HIUboiler219wwcurtemp2current extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_extern_temperaturesensor.boiler_wwcurtemp2
2453Greenstar HIUboiler219wwcurflowcurrent tap water flowuint (>=0<=25)l/minfalsesensor.boiler_current_tap_water_flowsensor.boiler_wwcurflow
2454Greenstar HIUboiler219wwstoragetemp1storage intern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_intern_temperaturesensor.boiler_wwstoragetemp1
2455Greenstar HIUboiler219wwstoragetemp2storage extern temperatureushort (>=0<=3199)Cfalsesensor.boiler_storage_extern_temperaturesensor.boiler_wwstoragetemp2
2456Greenstar HIUboiler219wwactivatedactivatedbooleantrueswitch.boiler_activatedswitch.boiler_wwactivated
2457Greenstar HIUboiler219wwonetimeone time chargingbooleantrueswitch.boiler_one_time_chargingswitch.boiler_wwonetime
2458Greenstar HIUboiler219wwdisinfectingdisinfectingbooleantrueswitch.boiler_disinfectingswitch.boiler_wwdisinfecting
2459Greenstar HIUboiler219wwchargingchargingbooleanfalsebinary_sensor.boiler_chargingbinary_sensor.boiler_wwcharging
2460Greenstar HIUboiler219wwrechargingrechargingbooleanfalsebinary_sensor.boiler_rechargingbinary_sensor.boiler_wwrecharging
2461Greenstar HIUboiler219wwtempoktemperature okbooleanfalsebinary_sensor.boiler_temperature_okbinary_sensor.boiler_wwtempok
2462Greenstar HIUboiler219wwactiveactivebooleanfalsebinary_sensor.boiler_activebinary_sensor.boiler_wwactive
2463Greenstar HIUboiler219ww3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_3-way_valve_activebinary_sensor.boiler_ww3wayvalve
2464Greenstar HIUboiler219wwsetpumppowerset pump poweruint (>=0<=100)%falsesensor.boiler_set_pump_powersensor.boiler_wwsetpumppower
2465Greenstar HIUboiler219wwmixertempmixer temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixer_temperaturesensor.boiler_wwmixertemp
2466Greenstar HIUboiler219wwcylmiddletempcylinder middle temperature (TS3)ushort (>=0<=3199)Cfalsesensor.boiler_cylinder_middle_temperature_(TS3)sensor.boiler_wwcylmiddletemp
2467Greenstar HIUboiler219wwstartsstartsulong (>=0<=65533)falsesensor.boiler_startssensor.boiler_wwstarts
2468Greenstar HIUboiler219wwworkmactive timetime (>=0<=65533)minutesfalsesensor.boiler_active_timesensor.boiler_wwworkm
2469Logamax Plus GB122/Condense 2300boiler234resetResetcmd [-\|maintenance\|error]truesensor.boiler_Resetsensor.boiler_reset
2470Logamax Plus GB122/Condense 2300boiler234heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive
2471Logamax Plus GB122/Condense 2300boiler234tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive
2472Logamax Plus GB122/Condense 2300boiler234selflowtempselected flow temperatureuint (>=0<=254)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp
2473Logamax Plus GB122/Condense 2300boiler234heatingpumpmodheating pump modulationuint (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod
2474Logamax Plus GB122/Condense 2300boiler234outdoortempoutside temperatureshort (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp
2475Logamax Plus GB122/Condense 2300boiler234curflowtempcurrent flow temperatureushort (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp
2476Logamax Plus GB122/Condense 2300boiler234rettempreturn temperatureushort (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp
2477Logamax Plus GB122/Condense 2300boiler234switchtempmixing switch temperatureushort (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp
2478Logamax Plus GB122/Condense 2300boiler234syspresssystem pressureuint (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress
2479Logamax Plus GB122/Condense 2300boiler234boiltempactual boiler temperatureushort (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp
2480Logamax Plus GB122/Condense 2300boiler234exhausttempexhaust temperatureushort (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp
2481Logamax Plus GB122/Condense 2300boiler234burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas
2482Logamax Plus GB122/Condense 2300boiler234burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas2
2483Logamax Plus GB122/Condense 2300boiler234flamecurrflame currentushort (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr
2484Logamax Plus GB122/Condense 2300boiler234heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump
2485Logamax Plus GB122/Condense 2300boiler234fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork
2486Logamax Plus GB122/Condense 2300boiler234ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork
2487Logamax Plus GB122/Condense 2300boiler234oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat
2488Logamax Plus GB122/Condense 2300boiler234heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated
2489Logamax Plus GB122/Condense 2300boiler234heatingtempheating temperatureuint (>=0<=254)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp
2490Logamax Plus GB122/Condense 2300boiler234pumpmodmaxboiler pump max poweruint (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax
2491Logamax Plus GB122/Condense 2300boiler234pumpmodminboiler pump min poweruint (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin
2492Logamax Plus GB122/Condense 2300boiler234pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode
2493Logamax Plus GB122/Condense 2300boiler234pumpdelaypump delayuint (>=0<=254)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay
2494Logamax Plus GB122/Condense 2300boiler234burnminperiodburner min perioduint (>=0<=254)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod
2495Logamax Plus GB122/Condense 2300boiler234burnminpowerburner min poweruint (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower
2496Logamax Plus GB122/Condense 2300boiler234burnmaxpowerburner max poweruint (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower
2497Logamax Plus GB122/Condense 2300boiler234boilhystonhysteresis on temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston
2498Logamax Plus GB122/Condense 2300boiler234boilhystoffhysteresis off temperatureint (>=-126<=126)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff
2499Logamax Plus GB122/Condense 2300boiler234boil2hystonhysteresis stage 2 on temperatureint (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston
2500Logamax Plus GB122/Condense 2300boiler234boil2hystoffhysteresis stage 2 off temperatureint (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff
The file is too large to be shown. View Raw