MQTT commands
All commands must be written as {"cmd":<cmd> ,"data":<data>, "id":<n>}.
The id can be replaced with hc for some devices that use heating circuits, and represented either as a string or a number. cmd is a string, data can be a string or number.
topic = boiler_cmd
comfort <hot, eco, intelligent>
flowtemp <degrees>
wwtemp <degrees>
boilhyston <degrees> (negative value)
boilhystoff <degrees> (positive value)
burnperiod <minutes>
burnminpower <%>
burnmaxpower <%>
pumpdelay <minutes>
topic = thermostat_cmd
--- without hc ---
wwmode <off | on | auto>
calinttemp <degrees>
minexttemp <degrees>
building <light | medium | heavy>
language <n> (0=de, 1=nl, 2=fr, 3=it) only RC30
display <n> (0=int temp, 1= int set, 2=ext. temp, 3=burner, 4=ww, 5=mode, 6=time, 7=date, 8=smoke) only RC30
clockoffset <seconds> (only RC30)
--- with hc ---
mode <auto | night | day | nofrost | heat | eco>
temp <degrees>
nighttemp <degrees>
daytemp <degrees>
nofrosttemp <degrees>
ecotemp <degrees>
heattemp <degrees>
summertemp <degrees>
designtemp <degrees>
offsettemp <degrees>
holidaytemp <degrees>
remotetemp <degrees>
control <0 | 1 | 2>
pause <hours>
party <hours>
holiday <dd.mm.yyyy-dd.mm.yyyy>
date <NTP | hh:mm:ss-dd.mm.yyyy-dw-dst>
topic = system_cmd
send <"0B XX XX ..">
pin <gpio> <on|off|1|0|true|false>