[3.6.1] September 9 2023
IMPORTANT! BREAKING CHANGES
shower_dataMQTT topic shows duration is seconds (was previously a full english sentence)
Added
- Show WiFi rssi in Network Status Page, show quality as color
Fixed
- Issue in espMqttClient causing a memory leak when MQTT broker is disconnected due to network unavailability #1264
- Using MQTT enum values correctly formatted in MQTT Discovery #1280
Changed
- MQTT free mem check set to 60 kb
- Small cosmetic changes to Searching in Customization web page
- Updated to espressif32@6.4.0
[3.6.0] August 13 2023
IMPORTANT! BREAKING CHANGES
There are breaking changes between 3.5.x and earlier versions of 3.6.0. Please read carefully before applying the update.
- The sensors have been renamed.
dallassensoris nowtemperaturesensorin the MQTT topic and namedtsin the Customizations file. Likewiseanalogsis nowanalogsensorin MQTT and calledasin the Customizations file. If you have previous customizations you will need to manually update by downloading, changing the JSON file and uploading. It's also recommended cleaning up any old MQTT topics from your broker using an application like MQTTExplorer.
Added
- Workaround for better Domoticz MQTT integration? #904
- Show MAC address without connecting to network enhancement #933
- Warn user in WebUI of unsaved changes #911
- Detect old Tado thermostat, device-id 0x19, no entities
- Some more HM200 entities #500
- Added Scheduler #701
- Added Custom Entities read/write from EMS bus
- Build S3 binary with github actions
- Greenstar HIU #1158
- AM200 code 10 #1161
- Ventilation device (Logavent HRV176) #1172
- Turn ETH off on wifi connect #1167
- Support for multiple EMS-ESPs with HA #1196
- Italian translation #1199
- Turkish language support #1076
- Buderus GB182 - HC1 mode change not work bug #1193
- Minimal flow temperature enhancement #1192
- Roomtemperature Switching Difference enhancement #1191
- Dew Point Temperature Difference enhancement #1190
- Control of heating circuit mode enhancement #1187
- Warn user in WebUI of unsaved changes enhancement #911
- Create safebuild app to fit into factory partition to give ESP32 more flash memory enhancement #608
- Support ESP32 S2, C3 mini and S3 #605
- Support Buderus AM200 #1161
- Custom telegram handler #1155
- Added support for TLS in MQTT (ESP32-S3 only) #1178
- Boardprofile BBQKees Gateway S3
- Custom entity type RAW #1212
- API command response #1212
Fixed
- HA-discovery for analog sensor commands #1035
- Enum order of RC3x nofrost mode
- Heartbeat interval
- Exhaust temperature always zero on GB125/MC110/RC310 bug #1147
- thermostat modetype is not changing when mode changes (e.g. to night) bugSomething isn't working #1098
- NTP: cant apply changed timezone #1182
- Missing Status of VS1 for Buderus SM200 enhancement #1034
- Allowed gpios for S3
Changed
- Optional upgrade to platform-espressif32 6.3.0 (after 5.3.0) #862
- Use byte 3 for detection RC30 active heatingcircuit #786
- Write repeated selflowtemp if tx-queue is empty without verify #954
- HA discovery recreate after disconnect by device #1067
- File upload: check flash size (overflow) instead of filesize
- Improved HA Discovery so previous configs no longer need to be removed when starting #1077 (thanks @pswid)
- Enlarge UART-Stack to 2,5k
- Retry timeout for Mqtt-QOS1/2 10seconds
- Optimize WebUI rendering when using Dialog Boxes #1116
- Optimize Web libraries to reduce bundle size (3.6.x) #1112
- Use espMqttClient with integrated queue #1178
- Move Sensors from Web dashboard to it's own tab enhancement #1170
- Optimize WebUI dashboard data #1169
- Replace React core library with Preact to save on memory footprint
- Response to
system/sendraw reads gives combined data for telegrams with more parts
[3.5.0] February 6 2023
IMPORTANT! BREAKING CHANGES
- When upgrading to v3.5 for the first time from v3.4 on a BBQKees Gateway board you will need to use the EMS-EPS Flasher to correctly re-partition the flash. Make sure you backup the settings and customizations from the WebUI (System->Upload/Download) and restore after the upgrade.
Added
- Translations in Web UI and all device entity names (DE, NL, SV, PL, NO, FR) #22
- Add support for Lolin C3 mini #620
- Add support for ESP32-S2 #667
- Add devices: Greenstar 30Ri boiler, Junkers FW500 thermostat, Buderus BC30 controller
- Add program memory info
- Add mqtt queue and connection infos
- Adapt min/max if ems-value is not in this range
- Add heat pump settings for inputs and limits #600
- Add hybrid heatpump #500
- Add translated tags
- Add min/max to customization table #686
- Add MD5 check #637
- Add more bus-ids #673
- Use HA connectivity device class for Status, added boot time #751
- Add commands for analog sensors outputs
- Support for multiple EMS-ESPs with MQTT and HA [#759]
- Settings for heatpump silent mode and additional heater [#802] [#803]
- Zone module MZ100 #826
- Default MQTT hostname is blank #829
- wwCurFlow for ems+ devices #829
- Add Rego 3000, TR120RF thermostats #917
- Add config for ESP32-S3
- Add heatpump silent mode and other entities #896
- Allow reboot to other partition (factory or asymetric OTA)
- Blacklist entities to remove from memory #891
- Add boiler pump operating mode #944
Fixed
- Factory Reset not working #628
- Valid 4 byte values #820
- Commands for multiple thermostats #826
- API queries for multiple devices #865
- Console crash when using call with command
hcxonly. #841 heatingPump2Modwas wrong, changed to absBurnPow [#908- Rounding of web input values
- Analog sensor with single gpio number #915
- HA dallas and analog configs: remove/rebuild on change #888
- Modes and set seltemp for RC30 and RC20 #932
Changed
- Discovery in HomeAssistant don't work with custom base topic. #596 Base topic containing
/are changed to_ - RF room temperature sensor are shown as thermostat
- Render mqtt float json values with trailing zero
- Removed flash strings, to increase available heap memory
- Reload page after restart button is pressed
- Analog/dallas values command as list like ems-devices
- Analog/dallas HA-entities based on id
- MQTT Base is a mandatory field. Removed MQTT topic length from settings
- HA duration class for time entities [#822
- AM200 alternative heatsource as class heatsource [#857
[3.4.2] September 18 2022
Added
- RC310 additions #520
- damping
- wwprio for RC310 heating circuits
- switchonoptimization for RC310 heating circuits
- enum_controlmode for RC310 (new enum list)
- nofrostmode, reducemode, reducetemp & noreducetemp for RC310
- emergencyops and emergencytemp, wwmaxtemp, wwflowtempoffset and wwcomfort1 for RC310
- HM200 hybrid module #500
- AM200 alternative heatsource module #573
- EM10 error module as gateway #575
Fixed
- fix Table resizing in WebUI #519
- allow larger customization files #570
- losing entitiy wwcomfort #581
Changed
- Shorten "friendly names" in Home Assistant #555
- platformio 2.3.0 (IDF 4, Arduino 2)
- remove master-thermostat, support multiple thermostats
- merge up- and download in webui #577
[3.4.1] May 29 2022
Fixed
- Fix memory leak in api #524
Changed
- Controller data in web-ui only for IVT #522
- Rename hidden
climateto a more explaining name #523 - Minor changes to the Customizations web page #527
[3.4.0] May 23 2022
Added
- WebUI optimizations, updated look&feel and better performance #124
- Auto refresh of WebUI after successful firmware upload #178
- New Customization Service in WebUI. First feature is the ability to enable/disabled Entities (device values) from EMS devices #206
- Option to disable Telnet Console #209
- Added Hide SSID, Max Clients and Preferred Channel to Access Point
- Merged in MichaelDvP's changes like Fahrenheit conversion, publish single (for IOBroker) and a few other critical optimizations
- Enabled bi-directional read/write with Home Assistant, so values can be changed automatically from the UI without scripting #265
- Added GC7000F Boiler #270
- Revised LED flash sequence on boot up to show system health (1 flash=no ems, 2 flashes=no wifi) #224
- Analog Sensor support #271
- Solar cylinder priority #247
- Read only mode in Settings, where EMS Tx/Write commands are blocked #286
- Added 8700i Boiler device
- Added Cascade CM10 Controller device
- Add Olimex ESP32-POE-ISO to board profiles plus settings to customize Ethernet modules #301
- Help text for string commands in WebUI #320
- Germany translations (at compile time)
- #entities added to system/info` endpoint #322
- analog outputs digital/pwm/dac
- remove MQTT retained configs if discovery is disabled
- timeout 10 min for MQTT-QoS wait
- Moduline 300 auto-temperatures T1-T4, RC300 romminfluencefactor
- RC35 parameters #392, #398
- sync time with thermostat #386, #408
- set mode has immediate effect #395
- min/max in web value setting
- Extend customization to select if an entity is to be shown in the WebUI or forced as read-only #317
- Added Moduline 400 installation parameters PR #449 by @kwertie01
- Read time from IVT-controller #439
- Hybrid Heatpump product-id 168 #459, thermostat settings
- Junkers ISM2 and IPM in warm water mode #437
- Added Shower Alert trigger time and cold shot time #436
- Improved Table layout in Web UI (searching, filtering, sorting, exporting to CSV)
- API fetch individual attributes from an entity #462
- Option to disable mDNS
- Option for rendering booleans on dashboard #456
- Upload customization settings from a file #256
Fixed
- lastcode broke MQTT JSON structure #228
- fixed issue with overlapping while reading sequence of EMS1.0 telegrams
- fixed redundant telegram readings (because of offset overflow)
- added missing RC30/Moduline 400 #243
- Correct modes for RC25 #106
- Clean up old HA config's in MQTT before publishing data. This will prevent HA giving the 'dict' warnings #229
- RC25 temperature setting #272
- Buderus RC25 - "hc1 mode type" incorrect value #273
- Increased number of Mixers and Heating Circuits #294
- Check receive status before removing a telegram fetch #268, #282
- Fix uploading firmware on OSX #345
- Non-nested MQTT would corrupt the json #354
- Burner selected max power can have a value higher than 100% #314
- some missing fahrenheit calculations
- limited number of exclusions #339
- MQTT sometimes would not reconnect after a WiFi outage
Changed
- Use flash system to show system health (1 flash=no ems, 2 flashes=no wifi) #224
- Renamed Dallas Sensor to Temperature Sensor in UI
- Dallas Format removed. Use the name to give each sensor an alias
- No longer MQTT subscribes to topic
/thermostat_hc<n>as it supports a path similar to the API endpoint construct - Show Sensors quality in WebUI
- Controller not shown in WebUI dashboard
- renamed "Home Assistant Integration" to "MQTT Discovery" in MQTT Settings #290
- Show ems tx reads and writes separately
- Show ems device handlers separated for received, fetched and pending handlers.
- Wired renamed to Ethernet
- removed system/pin command, new commands in analogsensors
- system/info device-info split to name/version/brand
- exclude list uses short-names, possible flags for web/api/mqtt excludes, readonly and favorite (selection not yet implemented)
- thermostat clock formate date-time: dd.mm.yyyy hh:mm
- RC300 summermode as other thermostats
winter/summerinstead ofoff/on
BREAKING CHANGES:
- Settings:
- order of Boolean Format has changed in Application Settings - check your settings
- Dallas Format setting removed. Now customize name of each Dallas sensor via the UI
- MQTT/API
- Boiler
wwheatrenamed toww3wayon#211 - Boiler
wwtag renamed todhw. Any custom Home Assistant lovelace dashboards will need updating. - Renamed description of
wwtapactivatedto "turn on/off DHW". Otherwise would have looked like "boiler_dhw_turn_on_off_dhw" in HA. /api/system/infoendpoint has updated keys. Now lowercase, no underscores and not capitalized. Replace "handlers" with "handlers received", "handlers fetched" and "handlers pending".
- Boiler
[3.3.1] January 20 2022
- lastcode broke MQTT JSON structure #228
- overlapping while reading sequence of EMS1.0 telegrams
- redundant telegram readings (because of offset overflow)
- added missing RC30/Moduline400 #243
- check received status before toggling fetch on empty telegram [#268][#282]
[3.3.0] November 28 2021
Added
- Add system commands for syslog level and watch #98
- Added pool data to telegrams 0x494 & 0x495 #102
- Add RC300 second summermode telegram #108
- Add support for the RC25 thermostat #106
- Add new command 'entities' for a device, e.g. http://ems-esp/api/boiler/entities to show the shortname, description and HA Entity name (if HA enabled) #116
- Support for Junkers program and remote (fb10/fb110) temperature
- Home Assistant
state_classattribute for Wh, kWh, W and KW #129 - Add current room influence for RC300 #136
- Added Home Assistant device_class to sensor entities
- Added another Buderus RC10 thermostat with Product ID 65 #160
- Added support for mDNS #161
- Added last system ESP32 reset code to log (and
system infooutput) - Firmware Checker in WebUI #168
- Added new MQTT setting for enabling 'response' topic
- Support for non-standard Thermostats like Tado #174
- Include MQTT connection status in 'api/system/info'
- Include Network status in 'api/system/info' and also the MQTT topic
info#202 - Added Ethernet PHY module as an option in the Board Profile #210
Fixed
- MQTT reconnecting after WiFi reconnect #99
- Manually Controlling Solar Circuit #107
- Fix thermostat commands not defaulting to the master thermostat #110
- Enlarge parse-buffer for long names like
cylinderpumpmodulation - MQTT not subscribing to all device entities #166
- Help fix issues with WebUI unable to fully load UI over Ethernet #177
- Shower alert never reset after limit reached when enabled [(PR #185)]
- Remove HA entity entries when a device value goes dormant #196
- deciphering last error code dates on 0xC2 telegram #204
Changed
- Syslog BOM only for utf-8 messages #91
- Check for KM200 by device-id 0x48, remove tx-delay #90
- rename
fastheatupfactortofastheatupand add percent #122 - "unit" renamed to "uom" in API call to recall a Device Value
- initial backend React changes to replace the class components (HOCs) with React Hooks
- Use program-names instead of numbers
- Boiler's maintenancemessage always published in MQTT (to prevent HA missing entity)
- Unit of Measure 'times' added to MQTT Fails, Rx fails, Rx received, Tx fails, Tx reads & Tx writes
- Improved API. Restful HTTP API works in the same way as MQTT calls
- Removed settings for MQTT subscribe format #173
- Improve Nefit Moduline 200 functionality #183
statusin the MQTT heartbeat renamed tobus_status- Layout changes in the WebUI, showing stripped table rows in Dashboard
- Alternative font for log window #219
BREAKING CHANGES
- API: "unit" renamed to "uom" in API call to recall a Device Value
- HA:
sensor.boiler_boiler_temperaturerenamed tosensor.actual_boiler_temperature - HA:
binary_sensor.boiler_ww_disinfectingrenamed tobinary_sensor.boiler_ww_disinfection - HA: # removed from counts in MQTT Fails, Rx fails, Rx received, Tx fails, Tx reads & Tx writes
txreadrenamed totxreadsandtxwriterenamed totxwritesin MQTT heartbeat payload- 'dallas sensors' in api/system/info moved to the "System" section. Renamed "uptime (seconds)" and "reset reason"
statusin the MQTT heartbeat renamed tobus_status
[3.2.1] August 8 2021
Added
- json body in API can now take device, name, cmd, hc and id
- added example of how to use API directly to control values from Home Assistant
- API calls are shown in debug log (For troubleshooting)
Fixed
- fixed issue with Home Assistant entity naming where boiler's ww was duplicated in entity name
- fixed issue where wwSetTemp was written too instead of wwSelTemp
Changed
- fixed case on mqtt names, like 'wwtankmiddletemp'
- renamed Product ID to 'EMS Product ID' in Home Assistant
- removed brackets around tags, e.g. (hc1) selected room temperature" is now just "hc1 selected room temperature"
[3.2.0] August 6 2021
Added
- support for IPv6 (web/api/mqtt, not syslog yet) #83
- System Log in Web UI will show current time if the NTP Service is enabled #82
- Network settings for Tx-power, WiFi-bandwidth, WiFi-sleepmode #83
- optional low CPU clockrate (160 MHz) #83
- select format for enumerated values in web
- settings for water hysteresis on/off
- dallas sensor name editable.
sensornameconsole-command, replace sensorid with a unique name #84 - 'restart' system command. Can be invoked via API with authentication. #87
- add Download button in Web UI for log
Fixed
- set mode allow numbers
- Junkers thermostat shows mode as selected by set_mode
- HA thermostat mode if bool-format: numbers is selected
- Web UI System Log sometimes skipped a few log messages when watching real-time
- fix wwactivated #89
- don't show commands (like reset) as Device values in the Web or Console
Changed
- removed Rx echo failures counting as incomplete telegrams. Bad telegrams show as Warning and not Errors. #80
- add upload_sec to
api/system/infoand removed # from some names to keep consistent with MQTT heartbeat - added debug target to PlatformIO build to help hunt down system crashes
- enumerated values always start at zero
- maintenance settings for time/date as extra setting
- move api/mqtt formats to
settings, addenum format - UI improvements for editing Dallas Sensor details
- RESTful GET commands can also require authentication (via bearer access token) for better security
- Updated AsyncMqttClient to 0.9.0 and ArduinoJson to 6.18.3
- Download buttons for settings and info under the Help tab
[3.1.1] June 26 2021
Added
- new command called
commandswhich lists all available commands.ems-esp/api/{device}/commands - More Home Assistant icons to match the UOMs
- new API. Using secure access tokens and OpenAPI standard. See
doc/EMS-ESP32 API.mdand #50 - show log messages in Web UI #71
Fixed
- HA thermostat mode was not in sync with actual mode #66
- Don't publish rssi if Wifi is disabled and ethernet is being used
- Booleans are shown as true/false in API GETs
Changed
infocommand always shows full names in API. For short names query the device or name directly, e.g.http://ems-esp/api/boiler- free memory is shown in kilobytes
- boiler's warm water entities have ww added to the Home Assistant entity name #67
- improved layout and rendering of device values in the WebUI, also the edit value screen
[3.1.0] May 4 2021
Added
- Mock API to simulate an ESP, for testing web
- Able to write values from the Web UI
- check values with
"cmd":<valuename>and data empty or? - set hc for values and commands by id or prefix
hc<x>+separator, separator can be any char
Fixed
- Don't create Home Assistant MQTT discovery entries for device values that don't exists (#756 on EMS-ESP repo)
- Update shower MQTT when a shower start is detected
- S32 board profile
Changed
- Icon for Network
- MQTT Formatting payload (nested vs single) is a pull-down option
- moved mqtt-topics and texts to local_EN, all topics lower case
- Re-enabled Shower Alert (still experimental)
- lowercased Flow temp in commands
- system console commands to main
[3.0.1] March 30 2021
Added
- individual mqtt commands (#31)
- board Profiles (#11)
Fixed
- Rx and Tx quality % would sometimes show > 100
Changed
- invert LED changed to Hide LED. Default is off.
- renamed Scan Network to Scan WiFi Network
- added version to cmd=settings
- Allow both WiFi and Ethernet together, fall back to AP when Ethernet disconnects
Removed
- Shower Alert (disabled for now)
[3.0.0] March 18 2021
Added
- Power settings, disabling BLE and turning off Wifi sleep
- Rx and Tx counts to Heartbeat MQTT payload
- Ethernet support
- id to info command to show only a heatingcircuit
- add sending devices that are not listed to 0x07
- extra MQTT boolean option for "ON" and "OFF"
- Support for chunked MQTT payloads to allow large data sets > 2kb
- External Button support (#708) for resetting to factory defaults and other actions
- new console set command in
system,set ethernet <profile>for quickly enabling cabled ethernet connections without using the captive wifi portal - Added in MQTT nested mode, for thermostat and mixer, like we had back in v2
- Cascade MC400 (product-id 210) (3.0.0b6)
- values for wwMaxPower, wwFlowtempOffset
- RC300
thermostat temp -1to clear temporary setpoint in auto mode - Syslog port selectable (#744)
Fixed
- telegrams matched to masterthermostat 0x18
- multiple roomcontrollers
- readback after write with delay (give ems-devices time to set the value)
- Thermostat ES72/RC20 device 66 to command-set RC20_2
- MQTT payloads not adding to queue when MQTT is re-connecting (fixes #369)
- fix for HA topics with invalid command formats (#728)
- wrong position of values #723, #732
- OTA Upload via Web on OSX
Changed
- changed how telegram parameters are rendered for mqtt, console and web (#632)
- split
show valuesin smaller packages (edited) - extended length of IP/hostname from 32 to 48 chars (#676)
- check flowsensor for
tap_water_active - mqtt prefixed with
Base - count Dallas sensor fails
- switch from SPIFFS to LITTLEFS
- Added ID to MQTT payloads which is the Device's product ID and used in HA to identify a unique HA device
- Increased MQTT buffer and reduced wait time between publishes
- Updated to the latest ArduinoJson library
- some names of mqtt-tags like in v2.2.1
- new ESP32 partition side to allow for smoother OTA and fallback
- Network Gateway IP is optional (#682)emsesp/EMS-ESP
- moved to a new GitHub repo https://github.com/emsesp/EMS-ESP32