The heat limit registers on heat pumps using EMS_DEVICE_FLAG_HEATPUMP
(product 172/173) are bytes 2/3/4 of telegram 0x0492, read as a direct
index into enum_maxHeat. That table has only six entries, so any unit
whose auxiliary electric heater goes above 9 kW reports an index the
table cannot resolve.
Nothing bounds-checks the raw byte on the way in, and every render path
guards on `value < options_size`, so an out-of-range index is dropped
silently: no value is published to MQTT, the API omits the field, Home
Assistant shows `unknown`, and nothing appears in the log. Helpers::
value2enum stops at the same boundary, so the value cannot be written
back from EMS-ESP either, leaving the entity permanently stuck.
Measured on a Bosch Compress 7000i AW (CS7000iAW 13 OR-T, product 172)
with a 15 kW auxiliary heater, by setting each limit from the unit's own
display and reading telegram 0x0492 back:
display 12 / 9 / 6 kW -> 0x0492 data: 03 00 06 05 04
raw kW note
0 0 agrees with the existing table
1 2 not offered by this heater
2 3 not offered by this heater
3 4 not offered by this heater
4 6 agrees with the existing table
5 9 agrees with the existing table
6 12 new
7 15 new
Indices 0, 4 and 5 match what EMS-ESP already decodes, which confirms the
existing entries and their ordering; the table was correct, just short.
The 2 kW and 4 kW entries belong to the 4-stufig (2/4/6/9 kW) heater
variant described in the HPC 410 service manual section 4.2.2, so a
3 kW-stepped heater simply skips them and walks 0, 3, 6, 9, 12, 15 kW,
i.e. raw 0, 2, 4, 5, 6, 7. The same sparse pattern is already encoded for
CS6800 devices in Boiler::process_HpHeaterConfig, which maps raw
{0, 2, 4, 5} onto {0, 3, 6, 9} kW.
Only devices carrying EMS_DEVICE_FLAG_HEATPUMP are affected; CS6800
devices use enum_maxHeat1/enum_maxHeat2 and are unchanged. Verified with
the standalone build: `test entity_dump` differs from the committed
docs/dump_entities.csv in exactly the six maxheat rows of products 172
and 173, and nowhere else.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
47 lines
3.4 KiB
Markdown
47 lines
3.4 KiB
Markdown
# Changelog
|
||
|
||
For more details go to [emsesp.org](https://emsesp.org/).
|
||
|
||
## [3.9.0]
|
||
|
||
This release is based on the latest Espressif/Arduino core version 3. It brings in many memory and performance optimizations. Note it does require the user to manually migrate settings from 3.8.x to 3.9.0.
|
||
|
||
## Added
|
||
|
||
- user-requested LED blink [#3063](https://github.com/emsesp/EMS-ESP32/issues/3063)
|
||
- Commands Service that can be called via MQTT or API or used in the Scheduler Service
|
||
- option to disable factory reset [#3150](https://github.com/emsesp/EMS-ESP32/issues/3150)
|
||
- TLS support with 4MB boards without PSRAM
|
||
- added eth_10mbit to Network Settings, which forces 10BASE-T half-duplex & autonegotiation off, halving the PHY’s power draw. It’s off by default as it will cause issues on managed switches with a port forced to 100Mb [#3213](https://github.com/emsesp/EMS-ESP32/pull/3213)
|
||
- cleaner MD5 and firmware uploading in WebUI [#3222](https://github.com/emsesp/EMS-ESP32/issues/3222)
|
||
- pc0Flow in l/min [#3224](https://github.com/emsesp/EMS-ESP32/issues/3224)
|
||
- remove HA config for excluded entities [#3229](https://github.com/emsesp/EMS-ESP32/issues/3229)
|
||
|
||
## Fixed
|
||
|
||
- shunting yard show json
|
||
- `system/sendmail` called from a Command or the Scheduler computed its value twice, which stripped the quotes from literal text and then failed on characters like `!`. Also shunting yard treated a `?` inside a quoted string as a ternary, so text like `"too hot?"` returned nothing
|
||
- memory leak when using different timezones for ems-esp and thermostat[#3184](https://github.com/emsesp/EMS-ESP32/issues/3184)
|
||
- LED stayed off on a healthy system when "Disable LED" was unchecked
|
||
- Ethernet MAC address changed with the new SDK, breaking DHCP reservations (currently disabled)
|
||
- "IPv4 nameserver" showed an IPv6 address when IPv6 was in use
|
||
- HA Discovery warning on Uptime after EMS-ESP boot due to NTP not ready
|
||
- hc/control setting for UI800 thermostats [#3181](https://github.com/emsesp/EMS-ESP32/discussions/3181)
|
||
- solar module switches [#3223](https://github.com/emsesp/EMS-ESP32/issues/3223)
|
||
- heat limit entities (`maxheatcomp`, `maxheatheat`, `dhw.maxheat`) read as unknown on heat pumps with an auxiliary heater larger than 9 kW - `enum_maxHeat` was missing the 12 kW and 15 kW steps
|
||
|
||
## Changed
|
||
|
||
- various memory optimizations [#3083](https://github.com/emsesp/EMS-ESP32/issues/3083)
|
||
- Scheduler name is now mandatory
|
||
- network fallback to AP only after start [#3090](https://github.com/emsesp/EMS-ESP32/issues/3090)
|
||
- replaced Web async-validator with custom validator and toast with native snackbar to reduce bundle size
|
||
- Gateway and Connect devices are shown in the Devices page, but disabled [3126](https://github.com/emsesp/EMS-ESP32/discussions/3126)
|
||
- show control setting only for master thermostats (0x10) [#3173](https://github.com/emsesp/EMS-ESP32/issues/3173)
|
||
- remove devices without entities not listed in 0x07 telegram
|
||
- changes to the Dialogs in Dashboard page, removed the run icon in the Commands page. Renamed Execute to Run.
|
||
- set `None` for undefined values in HA `val_tpl`
|
||
- changes in WebUI - remove multiple calls systemInfo endpoint, Vewrsion pages checks for internet connection [#3195](https://github.com/emsesp/EMS-ESP32/pull/3195)
|
||
- multiple optimization in network, power down WiFi when Ethernet and WiFi nosleep is instant when selected [#3213](https://github.com/emsesp/EMS-ESP32/pull/3213)
|
||
|