| 1 | device name | device type | product id | shortname | fullname | type [options...] \| (min/max) | uom | writeable | discovery entityid v3.4 | discovery entityid |
|---|---|---|---|---|---|---|---|---|---|---|
| 2 | CS6800i/WLW176i | boiler | 8 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 3 | CS6800i/WLW176i | boiler | 8 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 4 | CS6800i/WLW176i | boiler | 8 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 5 | CS6800i/WLW176i | boiler | 8 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 6 | CS6800i/WLW176i | boiler | 8 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 7 | CS6800i/WLW176i | boiler | 8 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 8 | CS6800i/WLW176i | boiler | 8 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 9 | CS6800i/WLW176i | boiler | 8 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 10 | CS6800i/WLW176i | boiler | 8 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 11 | CS6800i/WLW176i | boiler | 8 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 12 | CS6800i/WLW176i | boiler | 8 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 13 | CS6800i/WLW176i | boiler | 8 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 14 | CS6800i/WLW176i | boiler | 8 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 15 | CS6800i/WLW176i | boiler | 8 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 16 | CS6800i/WLW176i | boiler | 8 | heatingtemp | heating temperature | uint (>=0<=90) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 17 | CS6800i/WLW176i | boiler | 8 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 18 | CS6800i/WLW176i | boiler | 8 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 19 | CS6800i/WLW176i | boiler | 8 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 20 | CS6800i/WLW176i | boiler | 8 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 21 | CS6800i/WLW176i | boiler | 8 | pumpdelay | pump delay | uint (>=0<=60) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 22 | CS6800i/WLW176i | boiler | 8 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 23 | CS6800i/WLW176i | boiler | 8 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 24 | CS6800i/WLW176i | boiler | 8 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 25 | CS6800i/WLW176i | boiler | 8 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 26 | CS6800i/WLW176i | boiler | 8 | burnstarts | burner starts | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 27 | CS6800i/WLW176i | boiler | 8 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 28 | CS6800i/WLW176i | boiler | 8 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 29 | CS6800i/WLW176i | boiler | 8 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 30 | CS6800i/WLW176i | boiler | 8 | heatstarts | burner starts heating | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 31 | CS6800i/WLW176i | boiler | 8 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 32 | CS6800i/WLW176i | boiler | 8 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 33 | CS6800i/WLW176i | boiler | 8 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 34 | CS6800i/WLW176i | boiler | 8 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 35 | CS6800i/WLW176i | boiler | 8 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 36 | CS6800i/WLW176i | boiler | 8 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 37 | CS6800i/WLW176i | boiler | 8 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 38 | CS6800i/WLW176i | boiler | 8 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 39 | CS6800i/WLW176i | boiler | 8 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 40 | CS6800i/WLW176i | boiler | 8 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 41 | CS6800i/WLW176i | boiler | 8 | nrgtotal | total energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
| 42 | CS6800i/WLW176i | boiler | 8 | nrgww | energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_energy | sensor.boiler_nrgww |
| 43 | CS6800i/WLW176i | boiler | 8 | nrgheat | energy heating | ulong (>=0<=167772) | kWh | false | sensor.boiler_energy_heating | sensor.boiler_nrgheat |
| 44 | CS6800i/WLW176i | boiler | 8 | metertotal | meter total | ulong (>=0<=167772) | kWh | false | sensor.boiler_meter_total | sensor.boiler_metertotal |
| 45 | CS6800i/WLW176i | boiler | 8 | metercomp | meter compressor | ulong (>=0<=167772) | kWh | false | sensor.boiler_meter_compressor | sensor.boiler_metercomp |
| 46 | CS6800i/WLW176i | boiler | 8 | metereheat | meter e-heater | ulong (>=0<=167772) | kWh | false | sensor.boiler_meter_e-heater | sensor.boiler_metereheat |
| 47 | CS6800i/WLW176i | boiler | 8 | uptimetotal | heatpump total uptime | time (>=0<=279620) | minutes | false | sensor.boiler_heatpump_total_uptime | sensor.boiler_uptimetotal |
| 48 | CS6800i/WLW176i | boiler | 8 | uptimecontrol | total operating time heat | time (>=0<=279620) | minutes | false | sensor.boiler_total_operating_time_heat | sensor.boiler_uptimecontrol |
| 49 | CS6800i/WLW176i | boiler | 8 | uptimecompheating | operating time compressor heating | time (>=0<=279620) | minutes | false | sensor.boiler_operating_time_compressor_heating | sensor.boiler_uptimecompheating |
| 50 | CS6800i/WLW176i | boiler | 8 | uptimecompcooling | operating time compressor cooling | time (>=0<=279620) | minutes | false | sensor.boiler_operating_time_compressor_cooling | sensor.boiler_uptimecompcooling |
| 51 | CS6800i/WLW176i | boiler | 8 | uptimecompww | operating time compressor | time (>=0<=279620) | minutes | false | sensor.boiler_operating_time_compressor | sensor.boiler_uptimecompww |
| 52 | CS6800i/WLW176i | boiler | 8 | uptimecomppool | operating time compressor pool | time (>=0<=279620) | minutes | false | sensor.boiler_operating_time_compressor_pool | sensor.boiler_uptimecomppool |
| 53 | CS6800i/WLW176i | boiler | 8 | totalcompstarts | total compressor control starts | ulong (>=0<=16777213) | false | sensor.boiler_total_compressor_control_starts | sensor.boiler_totalcompstarts | |
| 54 | CS6800i/WLW176i | boiler | 8 | heatingstarts | heating control starts | ulong (>=0<=16777213) | false | sensor.boiler_heating_control_starts | sensor.boiler_heatingstarts | |
| 55 | CS6800i/WLW176i | boiler | 8 | coolingstarts | cooling control starts | ulong (>=0<=16777213) | false | sensor.boiler_cooling_control_starts | sensor.boiler_coolingstarts | |
| 56 | CS6800i/WLW176i | boiler | 8 | wwstarts2 | control starts2 | ulong (>=0<=16777213) | false | sensor.boiler_control_starts2 | sensor.boiler_wwstarts2 | |
| 57 | CS6800i/WLW176i | boiler | 8 | poolstarts | pool control starts | ulong (>=0<=16777213) | false | sensor.boiler_pool_control_starts | sensor.boiler_poolstarts | |
| 58 | CS6800i/WLW176i | boiler | 8 | nrgconstotal | total energy consumption | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_energy_consumption | sensor.boiler_nrgconstotal |
| 59 | CS6800i/WLW176i | boiler | 8 | nrgconscomptotal | total energy consumption compressor | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_energy_consumption_compressor | sensor.boiler_nrgconscomptotal |
| 60 | CS6800i/WLW176i | boiler | 8 | nrgconscompheating | energy consumption compressor heating | ulong (>=0<=16777213) | kWh | false | sensor.boiler_energy_consumption_compressor_heating | sensor.boiler_nrgconscompheating |
| 61 | CS6800i/WLW176i | boiler | 8 | nrgconscompww | energy consumption compressor | ulong (>=0<=16777213) | kWh | false | sensor.boiler_energy_consumption_compressor | sensor.boiler_nrgconscompww |
| 62 | CS6800i/WLW176i | boiler | 8 | nrgconscompcooling | energy consumption compressor cooling | ulong (>=0<=16777213) | kWh | false | sensor.boiler_energy_consumption_compressor_cooling | sensor.boiler_nrgconscompcooling |
| 63 | CS6800i/WLW176i | boiler | 8 | nrgconscomppool | energy consumption compressor pool | ulong (>=0<=16777213) | kWh | false | sensor.boiler_energy_consumption_compressor_pool | sensor.boiler_nrgconscomppool |
| 64 | CS6800i/WLW176i | boiler | 8 | auxelecheatnrgconstotal | total aux elec. heater energy consumption | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_aux_elec._heater_energy_consumption | sensor.boiler_auxelecheatnrgconstotal |
| 65 | CS6800i/WLW176i | boiler | 8 | auxelecheatnrgconsheating | aux elec. heater energy consumption heating | ulong (>=0<=16777213) | kWh | false | sensor.boiler_aux_elec._heater_energy_consumption_heating | sensor.boiler_auxelecheatnrgconsheating |
| 66 | CS6800i/WLW176i | boiler | 8 | auxelecheatnrgconsww | aux elec. heater energy consumption | ulong (>=0<=16777213) | kWh | false | sensor.boiler_aux_elec._heater_energy_consumption | sensor.boiler_auxelecheatnrgconsww |
| 67 | CS6800i/WLW176i | boiler | 8 | auxelecheatnrgconspool | aux elec. heater energy consumption pool | ulong (>=0<=16777213) | kWh | false | sensor.boiler_aux_elec._heater_energy_consumption_pool | sensor.boiler_auxelecheatnrgconspool |
| 68 | CS6800i/WLW176i | boiler | 8 | nrgsupptotal | total energy supplied | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_energy_supplied | sensor.boiler_nrgsupptotal |
| 69 | CS6800i/WLW176i | boiler | 8 | nrgsuppheating | total energy supplied heating | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_energy_supplied_heating | sensor.boiler_nrgsuppheating |
| 70 | CS6800i/WLW176i | boiler | 8 | nrgsuppww | total energy warm supplied | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_energy_warm_supplied | sensor.boiler_nrgsuppww |
| 71 | CS6800i/WLW176i | boiler | 8 | nrgsuppcooling | total energy supplied cooling | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_energy_supplied_cooling | sensor.boiler_nrgsuppcooling |
| 72 | CS6800i/WLW176i | boiler | 8 | nrgsupppool | total energy supplied pool | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_energy_supplied_pool | sensor.boiler_nrgsupppool |
| 73 | CS6800i/WLW176i | boiler | 8 | hppower | compressor power output | uint (>=0<=25) | kW | false | sensor.boiler_compressor_power_output | sensor.boiler_hppower |
| 74 | CS6800i/WLW176i | boiler | 8 | hpcompon | hp compressor | boolean | false | binary_sensor.boiler_hp_compressor | binary_sensor.boiler_hpcompon | |
| 75 | CS6800i/WLW176i | boiler | 8 | hpactivity | compressor activity | enum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost] | false | sensor.boiler_compressor_activity | sensor.boiler_hpactivity | |
| 76 | CS6800i/WLW176i | boiler | 8 | hpbrinepumpspd | brine pump speed | uint (>=0<=100) | % | false | sensor.boiler_brine_pump_speed | sensor.boiler_hpbrinepumpspd |
| 77 | CS6800i/WLW176i | boiler | 8 | hpswitchvalve | switch valve | boolean | false | binary_sensor.boiler_switch_valve | binary_sensor.boiler_hpswitchvalve | |
| 78 | CS6800i/WLW176i | boiler | 8 | hpcompspd | compressor speed | uint (>=0<=100) | % | false | sensor.boiler_compressor_speed | sensor.boiler_hpcompspd |
| 79 | CS6800i/WLW176i | boiler | 8 | hpcircspd | circulation pump speed | uint (>=0<=100) | % | false | sensor.boiler_circulation_pump_speed | sensor.boiler_hpcircspd |
| 80 | CS6800i/WLW176i | boiler | 8 | hpbrinein | brine in/evaporator | short (>=-3199<=3199) | C | false | sensor.boiler_brine_in/evaporator | sensor.boiler_hpbrinein |
| 81 | CS6800i/WLW176i | boiler | 8 | hpbrineout | brine out/condenser | short (>=-3199<=3199) | C | false | sensor.boiler_brine_out/condenser | sensor.boiler_hpbrineout |
| 82 | CS6800i/WLW176i | boiler | 8 | hptc0 | heat carrier return (TC0) | short (>=-3199<=3199) | C | false | sensor.boiler_heat_carrier_return_(TC0) | sensor.boiler_hptc0 |
| 83 | CS6800i/WLW176i | boiler | 8 | hptc1 | heat carrier forward (TC1) | short (>=-3199<=3199) | C | false | sensor.boiler_heat_carrier_forward_(TC1) | sensor.boiler_hptc1 |
| 84 | CS6800i/WLW176i | boiler | 8 | hptc3 | condenser temperature (TC3) | short (>=-3199<=3199) | C | false | sensor.boiler_condenser_temperature_(TC3) | sensor.boiler_hptc3 |
| 85 | CS6800i/WLW176i | boiler | 8 | hptr1 | compressor temperature (TR1) | short (>=-3199<=3199) | C | false | sensor.boiler_compressor_temperature_(TR1) | sensor.boiler_hptr1 |
| 86 | CS6800i/WLW176i | boiler | 8 | hptr3 | refrigerant temperature liquid side (condenser output) (TR3) | short (>=-3199<=3199) | C | false | sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) | sensor.boiler_hptr3 |
| 87 | CS6800i/WLW176i | boiler | 8 | hptr4 | evaporator inlet temperature (TR4) | short (>=-3199<=3199) | C | false | sensor.boiler_evaporator_inlet_temperature_(TR4) | sensor.boiler_hptr4 |
| 88 | CS6800i/WLW176i | boiler | 8 | hptr5 | compressor inlet temperature (TR5) | short (>=-3199<=3199) | C | false | sensor.boiler_compressor_inlet_temperature_(TR5) | sensor.boiler_hptr5 |
| 89 | CS6800i/WLW176i | boiler | 8 | hptr6 | compressor outlet temperature (TR6) | short (>=-3199<=3199) | C | false | sensor.boiler_compressor_outlet_temperature_(TR6) | sensor.boiler_hptr6 |
| 90 | CS6800i/WLW176i | boiler | 8 | hptr7 | refrigerant temperature gas side (condenser input) (TR7) | short (>=-3199<=3199) | C | false | sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7) | sensor.boiler_hptr7 |
| 91 | CS6800i/WLW176i | boiler | 8 | hptl2 | air inlet temperature (TL2) | short (>=-3199<=3199) | C | false | sensor.boiler_air_inlet_temperature_(TL2) | sensor.boiler_hptl2 |
| 92 | CS6800i/WLW176i | boiler | 8 | hppl1 | low pressure side temperature (PL1) | short (>=-3199<=3199) | C | false | sensor.boiler_low_pressure_side_temperature_(PL1) | sensor.boiler_hppl1 |
| 93 | CS6800i/WLW176i | boiler | 8 | hpph1 | high pressure side temperature (PH1) | short (>=-3199<=3199) | C | false | sensor.boiler_high_pressure_side_temperature_(PH1) | sensor.boiler_hpph1 |
| 94 | CS6800i/WLW176i | boiler | 8 | hpta4 | drain pan temp (TA4) | short (>=-3199<=3199) | C | false | sensor.boiler_drain_pan_temp_(TA4) | sensor.boiler_hpta4 |
| 95 | CS6800i/WLW176i | boiler | 8 | hptw1 | reservoir temp (TW1) | short (>=-3199<=3199) | C | false | sensor.boiler_reservoir_temp_(TW1) | sensor.boiler_hptw1 |
| 96 | CS6800i/WLW176i | boiler | 8 | poolsettemp | pool set temperature | uint (>=0<=127) | C | true | number.boiler_pool_set_temperature | number.boiler_poolsettemp |
| 97 | CS6800i/WLW176i | boiler | 8 | hp4way | 4-way valve (VR4) | enum [cooling & defrost\|heating & dhw] | false | sensor.boiler_4-way_valve_(VR4) | sensor.boiler_hp4way | |
| 98 | CS6800i/WLW176i | boiler | 8 | hpin1opt | input 1 options | string | true | sensor.boiler_input_1_options | sensor.boiler_hpin1opt | |
| 99 | CS6800i/WLW176i | boiler | 8 | hpin2opt | input 2 options | string | true | sensor.boiler_input_2_options | sensor.boiler_hpin2opt | |
| 100 | CS6800i/WLW176i | boiler | 8 | hpin3opt | input 3 options | string | true | sensor.boiler_input_3_options | sensor.boiler_hpin3opt | |
| 101 | CS6800i/WLW176i | boiler | 8 | hpin4opt | input 4 options | string | true | sensor.boiler_input_4_options | sensor.boiler_hpin4opt | |
| 102 | CS6800i/WLW176i | boiler | 8 | maxheatcomp | heat limit compressor | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | true | select.boiler_heat_limit_compressor | select.boiler_maxheatcomp | |
| 103 | CS6800i/WLW176i | boiler | 8 | maxheatheat | heat limit heating | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | true | select.boiler_heat_limit_heating | select.boiler_maxheatheat | |
| 104 | CS6800i/WLW176i | boiler | 8 | maxheatdhw | heat limit | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | true | select.boiler_heat_limit | select.boiler_maxheatdhw | |
| 105 | CS6800i/WLW176i | boiler | 8 | mandefrost | manual defrost | boolean | true | switch.boiler_manual_defrost | switch.boiler_mandefrost | |
| 106 | CS6800i/WLW176i | boiler | 8 | pvcooling | Cooling only with PV | boolean | true | switch.boiler_Cooling_only_with_PV | switch.boiler_pvcooling | |
| 107 | CS6800i/WLW176i | boiler | 8 | auxheateronly | aux heater only | boolean | true | switch.boiler_aux_heater_only | switch.boiler_auxheateronly | |
| 108 | CS6800i/WLW176i | boiler | 8 | auxheateroff | disable aux heater | boolean | true | switch.boiler_disable_aux_heater | switch.boiler_auxheateroff | |
| 109 | CS6800i/WLW176i | boiler | 8 | auxheaterstatus | aux heater status | boolean | false | binary_sensor.boiler_aux_heater_status | binary_sensor.boiler_auxheaterstatus | |
| 110 | CS6800i/WLW176i | boiler | 8 | auxheaterdelay | aux heater on delay | ushort (>=10<=1000) | K*min | true | number.boiler_aux_heater_on_delay | number.boiler_auxheaterdelay |
| 111 | CS6800i/WLW176i | boiler | 8 | auxmaxlimit | aux heater max limit | uint (>=0<=10) | K | true | number.boiler_aux_heater_max_limit | number.boiler_auxmaxlimit |
| 112 | CS6800i/WLW176i | boiler | 8 | auxlimitstart | aux heater limit start | uint (>=0<=10) | K | true | number.boiler_aux_heater_limit_start | number.boiler_auxlimitstart |
| 113 | CS6800i/WLW176i | boiler | 8 | auxheatrmode | aux heater mode | enum [eco\|comfort] | true | select.boiler_aux_heater_mode | select.boiler_auxheatrmode | |
| 114 | CS6800i/WLW176i | boiler | 8 | hphystheat | on/off hyst heat | ushort (>=50<=1500) | K*min | true | number.boiler_on/off_hyst_heat | number.boiler_hphystheat |
| 115 | CS6800i/WLW176i | boiler | 8 | hphystcool | on/off hyst cool | ushort (>=50<=1500) | K*min | true | number.boiler_on/off_hyst_cool | number.boiler_hphystcool |
| 116 | CS6800i/WLW176i | boiler | 8 | hphystpool | on/off hyst pool | ushort (>=50<=1500) | K*min | true | number.boiler_on/off_hyst_pool | number.boiler_hphystpool |
| 117 | CS6800i/WLW176i | boiler | 8 | silentmode | silent mode | enum [off\|auto\|on] | true | select.boiler_silent_mode | select.boiler_silentmode | |
| 118 | CS6800i/WLW176i | boiler | 8 | silentfrom | silent mode from | uint (>=0<=3810) | minutes | true | number.boiler_silent_mode_from | number.boiler_silentfrom |
| 119 | CS6800i/WLW176i | boiler | 8 | silentto | silent mode to | uint (>=0<=3810) | minutes | true | number.boiler_silent_mode_to | number.boiler_silentto |
| 120 | CS6800i/WLW176i | boiler | 8 | mintempsilent | min outside temp for silent mode | int (>=-126<=126) | C | true | number.boiler_min_outside_temp_for_silent_mode | number.boiler_mintempsilent |
| 121 | CS6800i/WLW176i | boiler | 8 | tempparmode | outside temp parallel mode | int (>=-126<=126) | C | true | number.boiler_outside_temp_parallel_mode | number.boiler_tempparmode |
| 122 | CS6800i/WLW176i | boiler | 8 | auxheatmix | aux heater mixing valve | int (>=-100<=100) | % | false | sensor.boiler_aux_heater_mixing_valve | sensor.boiler_auxheatmix |
| 123 | CS6800i/WLW176i | boiler | 8 | tempdiffheat | temp diff TC3/TC0 heat | uint (>=2<=10) | K | true | number.boiler_temp_diff_TC3/TC0_heat | number.boiler_tempdiffheat |
| 124 | CS6800i/WLW176i | boiler | 8 | tempdiffcool | temp diff TC3/TC0 cool | uint (>=2<=10) | K | true | number.boiler_temp_diff_TC3/TC0_cool | number.boiler_tempdiffcool |
| 125 | CS6800i/WLW176i | boiler | 8 | vpcooling | valve/pump cooling | boolean | true | switch.boiler_valve/pump_cooling | switch.boiler_vpcooling | |
| 126 | CS6800i/WLW176i | boiler | 8 | heatcable | heating cable | boolean | true | switch.boiler_heating_cable | switch.boiler_heatcable | |
| 127 | CS6800i/WLW176i | boiler | 8 | vc0valve | VC0 valve | boolean | true | switch.boiler_VC0_valve | switch.boiler_vc0valve | |
| 128 | CS6800i/WLW176i | boiler | 8 | primepump | primary heatpump | boolean | true | switch.boiler_primary_heatpump | switch.boiler_primepump | |
| 129 | CS6800i/WLW176i | boiler | 8 | primepumpmod | primary heatpump modulation | uint (>=0<=100) | % | true | number.boiler_primary_heatpump_modulation | number.boiler_primepumpmod |
| 130 | CS6800i/WLW176i | boiler | 8 | hp3way | 3-way valve | boolean | true | switch.boiler_3-way_valve | switch.boiler_hp3way | |
| 131 | CS6800i/WLW176i | boiler | 8 | elheatstep1 | el. heater step 1 | boolean | true | switch.boiler_el._heater_step_1 | switch.boiler_elheatstep1 | |
| 132 | CS6800i/WLW176i | boiler | 8 | elheatstep2 | el. heater step 2 | boolean | true | switch.boiler_el._heater_step_2 | switch.boiler_elheatstep2 | |
| 133 | CS6800i/WLW176i | boiler | 8 | elheatstep3 | el. heater step 3 | boolean | true | switch.boiler_el._heater_step_3 | switch.boiler_elheatstep3 | |
| 134 | CS6800i/WLW176i | boiler | 8 | hpea0 | condensate reservoir heating (EA0) | boolean | false | binary_sensor.boiler_condensate_reservoir_heating_(EA0) | binary_sensor.boiler_hpea0 | |
| 135 | CS6800i/WLW176i | boiler | 8 | wwalternatingop | alternating operation | boolean | true | switch.boiler_alternating_operation | switch.boiler_wwalternatingop | |
| 136 | CS6800i/WLW176i | boiler | 8 | wwaltopprioheat | prioritise heating during dhw | uint (>=20<=120) | minutes | true | number.boiler_prioritise_heating_during_dhw | number.boiler_wwaltopprioheat |
| 137 | CS6800i/WLW176i | boiler | 8 | wwaltopprioww | prioritise dhw during heating | uint (>=30<=120) | minutes | true | number.boiler_prioritise_dhw_during_heating | number.boiler_wwaltopprioww |
| 138 | CS6800i/WLW176i | boiler | 8 | wwcomfoff | comfort switch off | uint (>=15<=65) | C | true | number.boiler_comfort_switch_off | number.boiler_wwcomfoff |
| 139 | CS6800i/WLW176i | boiler | 8 | wwecooff | eco switch off | uint (>=15<=65) | C | true | number.boiler_eco_switch_off | number.boiler_wwecooff |
| 140 | CS6800i/WLW176i | boiler | 8 | wwecoplusoff | eco+ switch off | uint (>=48<=63) | C | true | number.boiler_eco+_switch_off | number.boiler_wwecoplusoff |
| 141 | CS6800i/WLW176i | boiler | 8 | hpcircpumpww | circulation pump available during dhw | boolean | true | switch.boiler_circulation_pump_available_during_dhw | switch.boiler_hpcircpumpww | |
| 142 | CS6800i/WLW176i | boiler | 8 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 143 | CS6800i/WLW176i | boiler | 8 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 144 | CS6800i/WLW176i | boiler | 8 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 145 | CS6800i/WLW176i | boiler | 8 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 146 | CS6800i/WLW176i | boiler | 8 | wwtempecoplus | selected eco+ temperature | uint (>=0<=254) | C | true | number.boiler_selected_eco+_temperature | number.boiler_wwtempecoplus |
| 147 | CS6800i/WLW176i | boiler | 8 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 148 | CS6800i/WLW176i | boiler | 8 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 149 | CS6800i/WLW176i | boiler | 8 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 150 | CS6800i/WLW176i | boiler | 8 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 151 | CS6800i/WLW176i | boiler | 8 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 152 | CS6800i/WLW176i | boiler | 8 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 153 | CS6800i/WLW176i | boiler | 8 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 154 | CS6800i/WLW176i | boiler | 8 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 155 | CS6800i/WLW176i | boiler | 8 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 156 | CS6800i/WLW176i | boiler | 8 | wwmaxtemp | maximum temperature | uint (>=0<=80) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 157 | CS6800i/WLW176i | boiler | 8 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 158 | CS6800i/WLW176i | boiler | 8 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 159 | CS6800i/WLW176i | boiler | 8 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 160 | CS6800i/WLW176i | boiler | 8 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 161 | CS6800i/WLW176i | boiler | 8 | wwdisinfectiontemp | disinfection temperature | uint (>=60<=80) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 162 | CS6800i/WLW176i | boiler | 8 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 163 | CS6800i/WLW176i | boiler | 8 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 164 | CS6800i/WLW176i | boiler | 8 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 165 | CS6800i/WLW176i | boiler | 8 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 166 | CS6800i/WLW176i | boiler | 8 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 167 | CS6800i/WLW176i | boiler | 8 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 168 | CS6800i/WLW176i | boiler | 8 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 169 | CS6800i/WLW176i | boiler | 8 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 170 | CS6800i/WLW176i | boiler | 8 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 171 | CS6800i/WLW176i | boiler | 8 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 172 | CS6800i/WLW176i | boiler | 8 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 173 | CS6800i/WLW176i | boiler | 8 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 174 | CS6800i/WLW176i | boiler | 8 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 175 | CS6800i/WLW176i | boiler | 8 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 176 | CS6800i/WLW176i | boiler | 8 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 177 | CS6800i/WLW176i | boiler | 8 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 178 | CS6800i/WLW176i | boiler | 8 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 179 | CS6800i/WLW176i | boiler | 8 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 180 | CS6800i/WLW176i | boiler | 8 | wwstarts | starts | ulong (>=0<=16777213) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 181 | CS6800i/WLW176i | boiler | 8 | wwworkm | active time | time (>=0<=16777213) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 182 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 183 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 184 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 185 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 186 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 187 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 188 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 189 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 190 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 191 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 192 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 193 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 194 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 195 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 196 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 197 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 198 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 199 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 200 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 201 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 202 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 203 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 204 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | burnminperiod | burner min period | uint (>=0<=120) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 205 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 206 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatblock | heating block | ushort (>=0<=3199) | C | false | sensor.boiler_heating_block | sensor.boiler_heatblock |
| 207 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | boilhyston | hysteresis on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 208 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | boilhystoff | hysteresis off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 209 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 210 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatingtemp | heating temperature | uint (>=0<=90) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 211 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 212 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 213 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 214 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 215 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | pumpdelay | pump delay | uint (>=0<=60) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 216 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 217 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 218 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 219 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 220 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | burnstarts | burner starts | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 221 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 222 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 223 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 224 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatstarts | burner starts heating | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 225 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 226 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 227 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 228 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 229 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 230 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 231 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 232 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 233 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 234 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 235 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 236 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 237 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 238 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 239 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwtempecoplus | selected eco+ temperature | uint (>=0<=254) | C | true | number.boiler_selected_eco+_temperature | number.boiler_wwtempecoplus |
| 240 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 241 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 242 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 243 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 244 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 245 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 246 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 247 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 248 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 249 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwmaxtemp | maximum temperature | uint (>=0<=80) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 250 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 251 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 252 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 253 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 254 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwdisinfectiontemp | disinfection temperature | uint (>=60<=80) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 255 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 256 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 257 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 258 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 259 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 260 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 261 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 262 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 263 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 264 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 265 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 266 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 267 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 268 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 269 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 270 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 271 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 272 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 273 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwstarts | starts | ulong (>=0<=16777213) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 274 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwworkm | active time | time (>=0<=16777213) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 275 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | nompower | nominal Power | uint (>=0<=254) | kW | true | number.boiler_nominal_Power | number.boiler_nompower |
| 276 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | nrgtotal | total energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
| 277 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | nrgheat | energy heating | ulong (>=0<=10000000) | kWh | true | number.boiler_energy_heating | number.boiler_nrgheat |
| 278 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | nrgww | energy | ulong (>=0<=10000000) | kWh | true | number.boiler_energy | number.boiler_nrgww |
| 279 | GB125/GB135/MC10 | boiler | 72 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 280 | GB125/GB135/MC10 | boiler | 72 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 281 | GB125/GB135/MC10 | boiler | 72 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 282 | GB125/GB135/MC10 | boiler | 72 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 283 | GB125/GB135/MC10 | boiler | 72 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 284 | GB125/GB135/MC10 | boiler | 72 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 285 | GB125/GB135/MC10 | boiler | 72 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 286 | GB125/GB135/MC10 | boiler | 72 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 287 | GB125/GB135/MC10 | boiler | 72 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 288 | GB125/GB135/MC10 | boiler | 72 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 289 | GB125/GB135/MC10 | boiler | 72 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 290 | GB125/GB135/MC10 | boiler | 72 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 291 | GB125/GB135/MC10 | boiler | 72 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 292 | GB125/GB135/MC10 | boiler | 72 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 293 | GB125/GB135/MC10 | boiler | 72 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 294 | GB125/GB135/MC10 | boiler | 72 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 295 | GB125/GB135/MC10 | boiler | 72 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 296 | GB125/GB135/MC10 | boiler | 72 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 297 | GB125/GB135/MC10 | boiler | 72 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 298 | GB125/GB135/MC10 | boiler | 72 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 299 | GB125/GB135/MC10 | boiler | 72 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 300 | GB125/GB135/MC10 | boiler | 72 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 301 | GB125/GB135/MC10 | boiler | 72 | burnminperiod | burner min period | uint (>=0<=120) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 302 | GB125/GB135/MC10 | boiler | 72 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 303 | GB125/GB135/MC10 | boiler | 72 | heatblock | heating block | ushort (>=0<=3199) | C | false | sensor.boiler_heating_block | sensor.boiler_heatblock |
| 304 | GB125/GB135/MC10 | boiler | 72 | boilhyston | hysteresis on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 305 | GB125/GB135/MC10 | boiler | 72 | boilhystoff | hysteresis off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 306 | GB125/GB135/MC10 | boiler | 72 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 307 | GB125/GB135/MC10 | boiler | 72 | heatingtemp | heating temperature | uint (>=0<=90) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 308 | GB125/GB135/MC10 | boiler | 72 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 309 | GB125/GB135/MC10 | boiler | 72 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 310 | GB125/GB135/MC10 | boiler | 72 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 311 | GB125/GB135/MC10 | boiler | 72 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 312 | GB125/GB135/MC10 | boiler | 72 | pumpdelay | pump delay | uint (>=0<=60) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 313 | GB125/GB135/MC10 | boiler | 72 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 314 | GB125/GB135/MC10 | boiler | 72 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 315 | GB125/GB135/MC10 | boiler | 72 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 316 | GB125/GB135/MC10 | boiler | 72 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 317 | GB125/GB135/MC10 | boiler | 72 | burnstarts | burner starts | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 318 | GB125/GB135/MC10 | boiler | 72 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 319 | GB125/GB135/MC10 | boiler | 72 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 320 | GB125/GB135/MC10 | boiler | 72 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 321 | GB125/GB135/MC10 | boiler | 72 | heatstarts | burner starts heating | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 322 | GB125/GB135/MC10 | boiler | 72 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 323 | GB125/GB135/MC10 | boiler | 72 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 324 | GB125/GB135/MC10 | boiler | 72 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 325 | GB125/GB135/MC10 | boiler | 72 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 326 | GB125/GB135/MC10 | boiler | 72 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 327 | GB125/GB135/MC10 | boiler | 72 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 328 | GB125/GB135/MC10 | boiler | 72 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 329 | GB125/GB135/MC10 | boiler | 72 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 330 | GB125/GB135/MC10 | boiler | 72 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 331 | GB125/GB135/MC10 | boiler | 72 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 332 | GB125/GB135/MC10 | boiler | 72 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 333 | GB125/GB135/MC10 | boiler | 72 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 334 | GB125/GB135/MC10 | boiler | 72 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 335 | GB125/GB135/MC10 | boiler | 72 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 336 | GB125/GB135/MC10 | boiler | 72 | wwtempecoplus | selected eco+ temperature | uint (>=0<=254) | C | true | number.boiler_selected_eco+_temperature | number.boiler_wwtempecoplus |
| 337 | GB125/GB135/MC10 | boiler | 72 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 338 | GB125/GB135/MC10 | boiler | 72 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 339 | GB125/GB135/MC10 | boiler | 72 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 340 | GB125/GB135/MC10 | boiler | 72 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 341 | GB125/GB135/MC10 | boiler | 72 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 342 | GB125/GB135/MC10 | boiler | 72 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 343 | GB125/GB135/MC10 | boiler | 72 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 344 | GB125/GB135/MC10 | boiler | 72 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 345 | GB125/GB135/MC10 | boiler | 72 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 346 | GB125/GB135/MC10 | boiler | 72 | wwmaxtemp | maximum temperature | uint (>=0<=80) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 347 | GB125/GB135/MC10 | boiler | 72 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 348 | GB125/GB135/MC10 | boiler | 72 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 349 | GB125/GB135/MC10 | boiler | 72 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 350 | GB125/GB135/MC10 | boiler | 72 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 351 | GB125/GB135/MC10 | boiler | 72 | wwdisinfectiontemp | disinfection temperature | uint (>=60<=80) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 352 | GB125/GB135/MC10 | boiler | 72 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 353 | GB125/GB135/MC10 | boiler | 72 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 354 | GB125/GB135/MC10 | boiler | 72 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 355 | GB125/GB135/MC10 | boiler | 72 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 356 | GB125/GB135/MC10 | boiler | 72 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 357 | GB125/GB135/MC10 | boiler | 72 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 358 | GB125/GB135/MC10 | boiler | 72 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 359 | GB125/GB135/MC10 | boiler | 72 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 360 | GB125/GB135/MC10 | boiler | 72 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 361 | GB125/GB135/MC10 | boiler | 72 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 362 | GB125/GB135/MC10 | boiler | 72 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 363 | GB125/GB135/MC10 | boiler | 72 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 364 | GB125/GB135/MC10 | boiler | 72 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 365 | GB125/GB135/MC10 | boiler | 72 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 366 | GB125/GB135/MC10 | boiler | 72 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 367 | GB125/GB135/MC10 | boiler | 72 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 368 | GB125/GB135/MC10 | boiler | 72 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 369 | GB125/GB135/MC10 | boiler | 72 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 370 | GB125/GB135/MC10 | boiler | 72 | wwstarts | starts | ulong (>=0<=16777213) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 371 | GB125/GB135/MC10 | boiler | 72 | wwworkm | active time | time (>=0<=16777213) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 372 | GB125/GB135/MC10 | boiler | 72 | nompower | nominal Power | uint (>=0<=254) | kW | true | number.boiler_nominal_Power | number.boiler_nompower |
| 373 | GB125/GB135/MC10 | boiler | 72 | nrgtotal | total energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
| 374 | GB125/GB135/MC10 | boiler | 72 | nrgheat | energy heating | ulong (>=0<=10000000) | kWh | true | number.boiler_energy_heating | number.boiler_nrgheat |
| 375 | GB125/GB135/MC10 | boiler | 72 | nrgww | energy | ulong (>=0<=10000000) | kWh | true | number.boiler_energy | number.boiler_nrgww |
| 376 | Cascade CM10 | boiler | 81 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 377 | Cascade CM10 | boiler | 81 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 378 | Cascade CM10 | boiler | 81 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 379 | Cascade CM10 | boiler | 81 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 380 | Cascade CM10 | boiler | 81 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 381 | Cascade CM10 | boiler | 81 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 382 | Cascade CM10 | boiler | 81 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 383 | Cascade CM10 | boiler | 81 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 384 | Cascade CM10 | boiler | 81 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 385 | Cascade CM10 | boiler | 81 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 386 | Cascade CM10 | boiler | 81 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 387 | Cascade CM10 | boiler | 81 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 388 | Cascade CM10 | boiler | 81 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 389 | Cascade CM10 | boiler | 81 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 390 | Cascade CM10 | boiler | 81 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 391 | Cascade CM10 | boiler | 81 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 392 | Cascade CM10 | boiler | 81 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 393 | Cascade CM10 | boiler | 81 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 394 | Cascade CM10 | boiler | 81 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 395 | Cascade CM10 | boiler | 81 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 396 | Cascade CM10 | boiler | 81 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 397 | Cascade CM10 | boiler | 81 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 398 | Cascade CM10 | boiler | 81 | burnminperiod | burner min period | uint (>=0<=120) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 399 | Cascade CM10 | boiler | 81 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 400 | Cascade CM10 | boiler | 81 | heatblock | heating block | ushort (>=0<=3199) | C | false | sensor.boiler_heating_block | sensor.boiler_heatblock |
| 401 | Cascade CM10 | boiler | 81 | boilhyston | hysteresis on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 402 | Cascade CM10 | boiler | 81 | boilhystoff | hysteresis off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 403 | Cascade CM10 | boiler | 81 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 404 | Cascade CM10 | boiler | 81 | heatingtemp | heating temperature | uint (>=0<=90) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 405 | Cascade CM10 | boiler | 81 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 406 | Cascade CM10 | boiler | 81 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 407 | Cascade CM10 | boiler | 81 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 408 | Cascade CM10 | boiler | 81 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 409 | Cascade CM10 | boiler | 81 | pumpdelay | pump delay | uint (>=0<=60) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 410 | Cascade CM10 | boiler | 81 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 411 | Cascade CM10 | boiler | 81 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 412 | Cascade CM10 | boiler | 81 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 413 | Cascade CM10 | boiler | 81 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 414 | Cascade CM10 | boiler | 81 | burnstarts | burner starts | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 415 | Cascade CM10 | boiler | 81 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 416 | Cascade CM10 | boiler | 81 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 417 | Cascade CM10 | boiler | 81 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 418 | Cascade CM10 | boiler | 81 | heatstarts | burner starts heating | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 419 | Cascade CM10 | boiler | 81 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 420 | Cascade CM10 | boiler | 81 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 421 | Cascade CM10 | boiler | 81 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 422 | Cascade CM10 | boiler | 81 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 423 | Cascade CM10 | boiler | 81 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 424 | Cascade CM10 | boiler | 81 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 425 | Cascade CM10 | boiler | 81 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 426 | Cascade CM10 | boiler | 81 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 427 | Cascade CM10 | boiler | 81 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 428 | Cascade CM10 | boiler | 81 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 429 | Cascade CM10 | boiler | 81 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 430 | Cascade CM10 | boiler | 81 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 431 | Cascade CM10 | boiler | 81 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 432 | Cascade CM10 | boiler | 81 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 433 | Cascade CM10 | boiler | 81 | wwtempecoplus | selected eco+ temperature | uint (>=0<=254) | C | true | number.boiler_selected_eco+_temperature | number.boiler_wwtempecoplus |
| 434 | Cascade CM10 | boiler | 81 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 435 | Cascade CM10 | boiler | 81 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 436 | Cascade CM10 | boiler | 81 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 437 | Cascade CM10 | boiler | 81 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 438 | Cascade CM10 | boiler | 81 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 439 | Cascade CM10 | boiler | 81 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 440 | Cascade CM10 | boiler | 81 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 441 | Cascade CM10 | boiler | 81 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 442 | Cascade CM10 | boiler | 81 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 443 | Cascade CM10 | boiler | 81 | wwmaxtemp | maximum temperature | uint (>=0<=80) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 444 | Cascade CM10 | boiler | 81 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 445 | Cascade CM10 | boiler | 81 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 446 | Cascade CM10 | boiler | 81 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 447 | Cascade CM10 | boiler | 81 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 448 | Cascade CM10 | boiler | 81 | wwdisinfectiontemp | disinfection temperature | uint (>=60<=80) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 449 | Cascade CM10 | boiler | 81 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 450 | Cascade CM10 | boiler | 81 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 451 | Cascade CM10 | boiler | 81 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 452 | Cascade CM10 | boiler | 81 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 453 | Cascade CM10 | boiler | 81 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 454 | Cascade CM10 | boiler | 81 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 455 | Cascade CM10 | boiler | 81 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 456 | Cascade CM10 | boiler | 81 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 457 | Cascade CM10 | boiler | 81 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 458 | Cascade CM10 | boiler | 81 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 459 | Cascade CM10 | boiler | 81 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 460 | Cascade CM10 | boiler | 81 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 461 | Cascade CM10 | boiler | 81 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 462 | Cascade CM10 | boiler | 81 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 463 | Cascade CM10 | boiler | 81 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 464 | Cascade CM10 | boiler | 81 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 465 | Cascade CM10 | boiler | 81 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 466 | Cascade CM10 | boiler | 81 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 467 | Cascade CM10 | boiler | 81 | wwstarts | starts | ulong (>=0<=16777213) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 468 | Cascade CM10 | boiler | 81 | wwworkm | active time | time (>=0<=16777213) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 469 | Cascade CM10 | boiler | 81 | nompower | nominal Power | uint (>=0<=254) | kW | true | number.boiler_nominal_Power | number.boiler_nompower |
| 470 | Cascade CM10 | boiler | 81 | nrgtotal | total energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
| 471 | Cascade CM10 | boiler | 81 | nrgheat | energy heating | ulong (>=0<=10000000) | kWh | true | number.boiler_energy_heating | number.boiler_nrgheat |
| 472 | Cascade CM10 | boiler | 81 | nrgww | energy | ulong (>=0<=10000000) | kWh | true | number.boiler_energy | number.boiler_nrgww |
| 473 | Logamax Plus GB022 | boiler | 84 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 474 | Logamax Plus GB022 | boiler | 84 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 475 | Logamax Plus GB022 | boiler | 84 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 476 | Logamax Plus GB022 | boiler | 84 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 477 | Logamax Plus GB022 | boiler | 84 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 478 | Logamax Plus GB022 | boiler | 84 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 479 | Logamax Plus GB022 | boiler | 84 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 480 | Logamax Plus GB022 | boiler | 84 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 481 | Logamax Plus GB022 | boiler | 84 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 482 | Logamax Plus GB022 | boiler | 84 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 483 | Logamax Plus GB022 | boiler | 84 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 484 | Logamax Plus GB022 | boiler | 84 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 485 | Logamax Plus GB022 | boiler | 84 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 486 | Logamax Plus GB022 | boiler | 84 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 487 | Logamax Plus GB022 | boiler | 84 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 488 | Logamax Plus GB022 | boiler | 84 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 489 | Logamax Plus GB022 | boiler | 84 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 490 | Logamax Plus GB022 | boiler | 84 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 491 | Logamax Plus GB022 | boiler | 84 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 492 | Logamax Plus GB022 | boiler | 84 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 493 | Logamax Plus GB022 | boiler | 84 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 494 | Logamax Plus GB022 | boiler | 84 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 495 | Logamax Plus GB022 | boiler | 84 | burnminperiod | burner min period | uint (>=0<=120) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 496 | Logamax Plus GB022 | boiler | 84 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 497 | Logamax Plus GB022 | boiler | 84 | heatblock | heating block | ushort (>=0<=3199) | C | false | sensor.boiler_heating_block | sensor.boiler_heatblock |
| 498 | Logamax Plus GB022 | boiler | 84 | boilhyston | hysteresis on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 499 | Logamax Plus GB022 | boiler | 84 | boilhystoff | hysteresis off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 500 | Logamax Plus GB022 | boiler | 84 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 501 | Logamax Plus GB022 | boiler | 84 | heatingtemp | heating temperature | uint (>=0<=90) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 502 | Logamax Plus GB022 | boiler | 84 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 503 | Logamax Plus GB022 | boiler | 84 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 504 | Logamax Plus GB022 | boiler | 84 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 505 | Logamax Plus GB022 | boiler | 84 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 506 | Logamax Plus GB022 | boiler | 84 | pumpdelay | pump delay | uint (>=0<=60) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 507 | Logamax Plus GB022 | boiler | 84 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 508 | Logamax Plus GB022 | boiler | 84 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 509 | Logamax Plus GB022 | boiler | 84 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 510 | Logamax Plus GB022 | boiler | 84 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 511 | Logamax Plus GB022 | boiler | 84 | burnstarts | burner starts | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 512 | Logamax Plus GB022 | boiler | 84 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 513 | Logamax Plus GB022 | boiler | 84 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 514 | Logamax Plus GB022 | boiler | 84 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 515 | Logamax Plus GB022 | boiler | 84 | heatstarts | burner starts heating | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 516 | Logamax Plus GB022 | boiler | 84 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 517 | Logamax Plus GB022 | boiler | 84 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 518 | Logamax Plus GB022 | boiler | 84 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 519 | Logamax Plus GB022 | boiler | 84 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 520 | Logamax Plus GB022 | boiler | 84 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 521 | Logamax Plus GB022 | boiler | 84 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 522 | Logamax Plus GB022 | boiler | 84 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 523 | Logamax Plus GB022 | boiler | 84 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 524 | Logamax Plus GB022 | boiler | 84 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 525 | Logamax Plus GB022 | boiler | 84 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 526 | Logamax Plus GB022 | boiler | 84 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 527 | Logamax Plus GB022 | boiler | 84 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 528 | Logamax Plus GB022 | boiler | 84 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 529 | Logamax Plus GB022 | boiler | 84 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 530 | Logamax Plus GB022 | boiler | 84 | wwtempecoplus | selected eco+ temperature | uint (>=0<=254) | C | true | number.boiler_selected_eco+_temperature | number.boiler_wwtempecoplus |
| 531 | Logamax Plus GB022 | boiler | 84 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 532 | Logamax Plus GB022 | boiler | 84 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 533 | Logamax Plus GB022 | boiler | 84 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 534 | Logamax Plus GB022 | boiler | 84 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 535 | Logamax Plus GB022 | boiler | 84 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 536 | Logamax Plus GB022 | boiler | 84 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 537 | Logamax Plus GB022 | boiler | 84 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 538 | Logamax Plus GB022 | boiler | 84 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 539 | Logamax Plus GB022 | boiler | 84 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 540 | Logamax Plus GB022 | boiler | 84 | wwmaxtemp | maximum temperature | uint (>=0<=80) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 541 | Logamax Plus GB022 | boiler | 84 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 542 | Logamax Plus GB022 | boiler | 84 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 543 | Logamax Plus GB022 | boiler | 84 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 544 | Logamax Plus GB022 | boiler | 84 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 545 | Logamax Plus GB022 | boiler | 84 | wwdisinfectiontemp | disinfection temperature | uint (>=60<=80) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 546 | Logamax Plus GB022 | boiler | 84 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 547 | Logamax Plus GB022 | boiler | 84 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 548 | Logamax Plus GB022 | boiler | 84 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 549 | Logamax Plus GB022 | boiler | 84 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 550 | Logamax Plus GB022 | boiler | 84 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 551 | Logamax Plus GB022 | boiler | 84 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 552 | Logamax Plus GB022 | boiler | 84 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 553 | Logamax Plus GB022 | boiler | 84 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 554 | Logamax Plus GB022 | boiler | 84 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 555 | Logamax Plus GB022 | boiler | 84 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 556 | Logamax Plus GB022 | boiler | 84 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 557 | Logamax Plus GB022 | boiler | 84 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 558 | Logamax Plus GB022 | boiler | 84 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 559 | Logamax Plus GB022 | boiler | 84 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 560 | Logamax Plus GB022 | boiler | 84 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 561 | Logamax Plus GB022 | boiler | 84 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 562 | Logamax Plus GB022 | boiler | 84 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 563 | Logamax Plus GB022 | boiler | 84 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 564 | Logamax Plus GB022 | boiler | 84 | wwstarts | starts | ulong (>=0<=16777213) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 565 | Logamax Plus GB022 | boiler | 84 | wwworkm | active time | time (>=0<=16777213) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 566 | Logamax Plus GB022 | boiler | 84 | nompower | nominal Power | uint (>=0<=254) | kW | true | number.boiler_nominal_Power | number.boiler_nompower |
| 567 | Logamax Plus GB022 | boiler | 84 | nrgtotal | total energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
| 568 | Logamax Plus GB022 | boiler | 84 | nrgheat | energy heating | ulong (>=0<=10000000) | kWh | true | number.boiler_energy_heating | number.boiler_nrgheat |
| 569 | Logamax Plus GB022 | boiler | 84 | nrgww | energy | ulong (>=0<=10000000) | kWh | true | number.boiler_energy | number.boiler_nrgww |
| 570 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 571 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 572 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 573 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 574 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 575 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 576 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 577 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 578 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 579 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 580 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 581 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 582 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 583 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 584 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 585 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 586 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 587 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 588 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 589 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 590 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 591 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 592 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burnminperiod | burner min period | uint (>=0<=120) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 593 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 594 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatblock | heating block | ushort (>=0<=3199) | C | false | sensor.boiler_heating_block | sensor.boiler_heatblock |
| 595 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | boilhyston | hysteresis on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 596 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | boilhystoff | hysteresis off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 597 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 598 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatingtemp | heating temperature | uint (>=0<=90) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 599 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 600 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 601 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 602 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 603 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | pumpdelay | pump delay | uint (>=0<=60) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 604 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 605 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 606 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 607 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 608 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burnstarts | burner starts | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 609 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 610 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 611 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 612 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatstarts | burner starts heating | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 613 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 614 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 615 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 616 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 617 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 618 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 619 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 620 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 621 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 622 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 623 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 624 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 625 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 626 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 627 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwtempecoplus | selected eco+ temperature | uint (>=0<=254) | C | true | number.boiler_selected_eco+_temperature | number.boiler_wwtempecoplus |
| 628 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 629 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 630 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 631 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 632 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 633 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 634 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 635 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 636 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 637 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwmaxtemp | maximum temperature | uint (>=0<=80) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 638 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 639 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 640 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 641 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 642 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwdisinfectiontemp | disinfection temperature | uint (>=60<=80) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 643 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 644 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 645 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 646 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 647 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 648 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 649 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 650 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 651 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 652 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 653 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 654 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 655 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 656 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 657 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 658 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 659 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 660 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 661 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwstarts | starts | ulong (>=0<=16777213) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 662 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwworkm | active time | time (>=0<=16777213) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 663 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | nompower | nominal Power | uint (>=0<=254) | kW | true | number.boiler_nominal_Power | number.boiler_nompower |
| 664 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | nrgtotal | total energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
| 665 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | nrgheat | energy heating | ulong (>=0<=10000000) | kWh | true | number.boiler_energy_heating | number.boiler_nrgheat |
| 666 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | nrgww | energy | ulong (>=0<=10000000) | kWh | true | number.boiler_energy | number.boiler_nrgww |
| 667 | Topline/GB162 | boiler | 115 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 668 | Topline/GB162 | boiler | 115 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 669 | Topline/GB162 | boiler | 115 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 670 | Topline/GB162 | boiler | 115 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 671 | Topline/GB162 | boiler | 115 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 672 | Topline/GB162 | boiler | 115 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 673 | Topline/GB162 | boiler | 115 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 674 | Topline/GB162 | boiler | 115 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 675 | Topline/GB162 | boiler | 115 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 676 | Topline/GB162 | boiler | 115 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 677 | Topline/GB162 | boiler | 115 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 678 | Topline/GB162 | boiler | 115 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 679 | Topline/GB162 | boiler | 115 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 680 | Topline/GB162 | boiler | 115 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 681 | Topline/GB162 | boiler | 115 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 682 | Topline/GB162 | boiler | 115 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 683 | Topline/GB162 | boiler | 115 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 684 | Topline/GB162 | boiler | 115 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 685 | Topline/GB162 | boiler | 115 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 686 | Topline/GB162 | boiler | 115 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 687 | Topline/GB162 | boiler | 115 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 688 | Topline/GB162 | boiler | 115 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 689 | Topline/GB162 | boiler | 115 | burnminperiod | burner min period | uint (>=0<=120) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 690 | Topline/GB162 | boiler | 115 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 691 | Topline/GB162 | boiler | 115 | heatblock | heating block | ushort (>=0<=3199) | C | false | sensor.boiler_heating_block | sensor.boiler_heatblock |
| 692 | Topline/GB162 | boiler | 115 | boilhyston | hysteresis on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 693 | Topline/GB162 | boiler | 115 | boilhystoff | hysteresis off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 694 | Topline/GB162 | boiler | 115 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 695 | Topline/GB162 | boiler | 115 | heatingtemp | heating temperature | uint (>=0<=90) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 696 | Topline/GB162 | boiler | 115 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 697 | Topline/GB162 | boiler | 115 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 698 | Topline/GB162 | boiler | 115 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 699 | Topline/GB162 | boiler | 115 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 700 | Topline/GB162 | boiler | 115 | pumpdelay | pump delay | uint (>=0<=60) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 701 | Topline/GB162 | boiler | 115 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 702 | Topline/GB162 | boiler | 115 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 703 | Topline/GB162 | boiler | 115 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 704 | Topline/GB162 | boiler | 115 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 705 | Topline/GB162 | boiler | 115 | burnstarts | burner starts | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 706 | Topline/GB162 | boiler | 115 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 707 | Topline/GB162 | boiler | 115 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 708 | Topline/GB162 | boiler | 115 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 709 | Topline/GB162 | boiler | 115 | heatstarts | burner starts heating | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 710 | Topline/GB162 | boiler | 115 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 711 | Topline/GB162 | boiler | 115 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 712 | Topline/GB162 | boiler | 115 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 713 | Topline/GB162 | boiler | 115 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 714 | Topline/GB162 | boiler | 115 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 715 | Topline/GB162 | boiler | 115 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 716 | Topline/GB162 | boiler | 115 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 717 | Topline/GB162 | boiler | 115 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 718 | Topline/GB162 | boiler | 115 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 719 | Topline/GB162 | boiler | 115 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 720 | Topline/GB162 | boiler | 115 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 721 | Topline/GB162 | boiler | 115 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 722 | Topline/GB162 | boiler | 115 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 723 | Topline/GB162 | boiler | 115 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 724 | Topline/GB162 | boiler | 115 | wwtempecoplus | selected eco+ temperature | uint (>=0<=254) | C | true | number.boiler_selected_eco+_temperature | number.boiler_wwtempecoplus |
| 725 | Topline/GB162 | boiler | 115 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 726 | Topline/GB162 | boiler | 115 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 727 | Topline/GB162 | boiler | 115 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 728 | Topline/GB162 | boiler | 115 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 729 | Topline/GB162 | boiler | 115 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 730 | Topline/GB162 | boiler | 115 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 731 | Topline/GB162 | boiler | 115 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 732 | Topline/GB162 | boiler | 115 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 733 | Topline/GB162 | boiler | 115 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 734 | Topline/GB162 | boiler | 115 | wwmaxtemp | maximum temperature | uint (>=0<=80) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 735 | Topline/GB162 | boiler | 115 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 736 | Topline/GB162 | boiler | 115 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 737 | Topline/GB162 | boiler | 115 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 738 | Topline/GB162 | boiler | 115 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 739 | Topline/GB162 | boiler | 115 | wwdisinfectiontemp | disinfection temperature | uint (>=60<=80) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 740 | Topline/GB162 | boiler | 115 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 741 | Topline/GB162 | boiler | 115 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 742 | Topline/GB162 | boiler | 115 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 743 | Topline/GB162 | boiler | 115 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 744 | Topline/GB162 | boiler | 115 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 745 | Topline/GB162 | boiler | 115 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 746 | Topline/GB162 | boiler | 115 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 747 | Topline/GB162 | boiler | 115 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 748 | Topline/GB162 | boiler | 115 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 749 | Topline/GB162 | boiler | 115 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 750 | Topline/GB162 | boiler | 115 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 751 | Topline/GB162 | boiler | 115 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 752 | Topline/GB162 | boiler | 115 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 753 | Topline/GB162 | boiler | 115 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 754 | Topline/GB162 | boiler | 115 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 755 | Topline/GB162 | boiler | 115 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 756 | Topline/GB162 | boiler | 115 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 757 | Topline/GB162 | boiler | 115 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 758 | Topline/GB162 | boiler | 115 | wwstarts | starts | ulong (>=0<=16777213) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 759 | Topline/GB162 | boiler | 115 | wwworkm | active time | time (>=0<=16777213) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 760 | Topline/GB162 | boiler | 115 | nompower | nominal Power | uint (>=0<=254) | kW | true | number.boiler_nominal_Power | number.boiler_nompower |
| 761 | Topline/GB162 | boiler | 115 | nrgtotal | total energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
| 762 | Topline/GB162 | boiler | 115 | nrgheat | energy heating | ulong (>=0<=10000000) | kWh | true | number.boiler_energy_heating | number.boiler_nrgheat |
| 763 | Topline/GB162 | boiler | 115 | nrgww | energy | ulong (>=0<=10000000) | kWh | true | number.boiler_energy | number.boiler_nrgww |
| 764 | Cascade MCM10 | boiler | 121 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 765 | Cascade MCM10 | boiler | 121 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 766 | Cascade MCM10 | boiler | 121 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 767 | Cascade MCM10 | boiler | 121 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 768 | Cascade MCM10 | boiler | 121 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 769 | Cascade MCM10 | boiler | 121 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 770 | Cascade MCM10 | boiler | 121 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 771 | Cascade MCM10 | boiler | 121 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 772 | Cascade MCM10 | boiler | 121 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 773 | Cascade MCM10 | boiler | 121 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 774 | Cascade MCM10 | boiler | 121 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 775 | Cascade MCM10 | boiler | 121 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 776 | Cascade MCM10 | boiler | 121 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 777 | Cascade MCM10 | boiler | 121 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 778 | Cascade MCM10 | boiler | 121 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 779 | Cascade MCM10 | boiler | 121 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 780 | Cascade MCM10 | boiler | 121 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 781 | Cascade MCM10 | boiler | 121 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 782 | Cascade MCM10 | boiler | 121 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 783 | Cascade MCM10 | boiler | 121 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 784 | Cascade MCM10 | boiler | 121 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 785 | Cascade MCM10 | boiler | 121 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 786 | Cascade MCM10 | boiler | 121 | burnminperiod | burner min period | uint (>=0<=120) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 787 | Cascade MCM10 | boiler | 121 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 788 | Cascade MCM10 | boiler | 121 | heatblock | heating block | ushort (>=0<=3199) | C | false | sensor.boiler_heating_block | sensor.boiler_heatblock |
| 789 | Cascade MCM10 | boiler | 121 | boilhyston | hysteresis on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 790 | Cascade MCM10 | boiler | 121 | boilhystoff | hysteresis off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 791 | Cascade MCM10 | boiler | 121 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 792 | Cascade MCM10 | boiler | 121 | heatingtemp | heating temperature | uint (>=0<=90) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 793 | Cascade MCM10 | boiler | 121 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 794 | Cascade MCM10 | boiler | 121 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 795 | Cascade MCM10 | boiler | 121 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 796 | Cascade MCM10 | boiler | 121 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 797 | Cascade MCM10 | boiler | 121 | pumpdelay | pump delay | uint (>=0<=60) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 798 | Cascade MCM10 | boiler | 121 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 799 | Cascade MCM10 | boiler | 121 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 800 | Cascade MCM10 | boiler | 121 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 801 | Cascade MCM10 | boiler | 121 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 802 | Cascade MCM10 | boiler | 121 | burnstarts | burner starts | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 803 | Cascade MCM10 | boiler | 121 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 804 | Cascade MCM10 | boiler | 121 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 805 | Cascade MCM10 | boiler | 121 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 806 | Cascade MCM10 | boiler | 121 | heatstarts | burner starts heating | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 807 | Cascade MCM10 | boiler | 121 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 808 | Cascade MCM10 | boiler | 121 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 809 | Cascade MCM10 | boiler | 121 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 810 | Cascade MCM10 | boiler | 121 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 811 | Cascade MCM10 | boiler | 121 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 812 | Cascade MCM10 | boiler | 121 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 813 | Cascade MCM10 | boiler | 121 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 814 | Cascade MCM10 | boiler | 121 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 815 | Cascade MCM10 | boiler | 121 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 816 | Cascade MCM10 | boiler | 121 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 817 | Cascade MCM10 | boiler | 121 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 818 | Cascade MCM10 | boiler | 121 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 819 | Cascade MCM10 | boiler | 121 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 820 | Cascade MCM10 | boiler | 121 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 821 | Cascade MCM10 | boiler | 121 | wwtempecoplus | selected eco+ temperature | uint (>=0<=254) | C | true | number.boiler_selected_eco+_temperature | number.boiler_wwtempecoplus |
| 822 | Cascade MCM10 | boiler | 121 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 823 | Cascade MCM10 | boiler | 121 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 824 | Cascade MCM10 | boiler | 121 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 825 | Cascade MCM10 | boiler | 121 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 826 | Cascade MCM10 | boiler | 121 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 827 | Cascade MCM10 | boiler | 121 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 828 | Cascade MCM10 | boiler | 121 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 829 | Cascade MCM10 | boiler | 121 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 830 | Cascade MCM10 | boiler | 121 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 831 | Cascade MCM10 | boiler | 121 | wwmaxtemp | maximum temperature | uint (>=0<=80) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 832 | Cascade MCM10 | boiler | 121 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 833 | Cascade MCM10 | boiler | 121 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 834 | Cascade MCM10 | boiler | 121 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 835 | Cascade MCM10 | boiler | 121 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 836 | Cascade MCM10 | boiler | 121 | wwdisinfectiontemp | disinfection temperature | uint (>=60<=80) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 837 | Cascade MCM10 | boiler | 121 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 838 | Cascade MCM10 | boiler | 121 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 839 | Cascade MCM10 | boiler | 121 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 840 | Cascade MCM10 | boiler | 121 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 841 | Cascade MCM10 | boiler | 121 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 842 | Cascade MCM10 | boiler | 121 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 843 | Cascade MCM10 | boiler | 121 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 844 | Cascade MCM10 | boiler | 121 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 845 | Cascade MCM10 | boiler | 121 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 846 | Cascade MCM10 | boiler | 121 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 847 | Cascade MCM10 | boiler | 121 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 848 | Cascade MCM10 | boiler | 121 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 849 | Cascade MCM10 | boiler | 121 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 850 | Cascade MCM10 | boiler | 121 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 851 | Cascade MCM10 | boiler | 121 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 852 | Cascade MCM10 | boiler | 121 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 853 | Cascade MCM10 | boiler | 121 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 854 | Cascade MCM10 | boiler | 121 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 855 | Cascade MCM10 | boiler | 121 | wwstarts | starts | ulong (>=0<=16777213) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 856 | Cascade MCM10 | boiler | 121 | wwworkm | active time | time (>=0<=16777213) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 857 | Cascade MCM10 | boiler | 121 | nompower | nominal Power | uint (>=0<=254) | kW | true | number.boiler_nominal_Power | number.boiler_nompower |
| 858 | Cascade MCM10 | boiler | 121 | nrgtotal | total energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
| 859 | Cascade MCM10 | boiler | 121 | nrgheat | energy heating | ulong (>=0<=10000000) | kWh | true | number.boiler_energy_heating | number.boiler_nrgheat |
| 860 | Cascade MCM10 | boiler | 121 | nrgww | energy | ulong (>=0<=10000000) | kWh | true | number.boiler_energy | number.boiler_nrgww |
| 861 | Proline | boiler | 122 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 862 | Proline | boiler | 122 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 863 | Proline | boiler | 122 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 864 | Proline | boiler | 122 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 865 | Proline | boiler | 122 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 866 | Proline | boiler | 122 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 867 | Proline | boiler | 122 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 868 | Proline | boiler | 122 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 869 | Proline | boiler | 122 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 870 | Proline | boiler | 122 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 871 | Proline | boiler | 122 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 872 | Proline | boiler | 122 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 873 | Proline | boiler | 122 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 874 | Proline | boiler | 122 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 875 | Proline | boiler | 122 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 876 | Proline | boiler | 122 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 877 | Proline | boiler | 122 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 878 | Proline | boiler | 122 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 879 | Proline | boiler | 122 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 880 | Proline | boiler | 122 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 881 | Proline | boiler | 122 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 882 | Proline | boiler | 122 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 883 | Proline | boiler | 122 | burnminperiod | burner min period | uint (>=0<=120) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 884 | Proline | boiler | 122 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 885 | Proline | boiler | 122 | heatblock | heating block | ushort (>=0<=3199) | C | false | sensor.boiler_heating_block | sensor.boiler_heatblock |
| 886 | Proline | boiler | 122 | boilhyston | hysteresis on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 887 | Proline | boiler | 122 | boilhystoff | hysteresis off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 888 | Proline | boiler | 122 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 889 | Proline | boiler | 122 | heatingtemp | heating temperature | uint (>=0<=90) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 890 | Proline | boiler | 122 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 891 | Proline | boiler | 122 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 892 | Proline | boiler | 122 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 893 | Proline | boiler | 122 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 894 | Proline | boiler | 122 | pumpdelay | pump delay | uint (>=0<=60) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 895 | Proline | boiler | 122 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 896 | Proline | boiler | 122 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 897 | Proline | boiler | 122 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 898 | Proline | boiler | 122 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 899 | Proline | boiler | 122 | burnstarts | burner starts | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 900 | Proline | boiler | 122 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 901 | Proline | boiler | 122 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 902 | Proline | boiler | 122 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 903 | Proline | boiler | 122 | heatstarts | burner starts heating | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 904 | Proline | boiler | 122 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 905 | Proline | boiler | 122 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 906 | Proline | boiler | 122 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 907 | Proline | boiler | 122 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 908 | Proline | boiler | 122 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 909 | Proline | boiler | 122 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 910 | Proline | boiler | 122 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 911 | Proline | boiler | 122 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 912 | Proline | boiler | 122 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 913 | Proline | boiler | 122 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 914 | Proline | boiler | 122 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 915 | Proline | boiler | 122 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 916 | Proline | boiler | 122 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 917 | Proline | boiler | 122 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 918 | Proline | boiler | 122 | wwtempecoplus | selected eco+ temperature | uint (>=0<=254) | C | true | number.boiler_selected_eco+_temperature | number.boiler_wwtempecoplus |
| 919 | Proline | boiler | 122 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 920 | Proline | boiler | 122 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 921 | Proline | boiler | 122 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 922 | Proline | boiler | 122 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 923 | Proline | boiler | 122 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 924 | Proline | boiler | 122 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 925 | Proline | boiler | 122 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 926 | Proline | boiler | 122 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 927 | Proline | boiler | 122 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 928 | Proline | boiler | 122 | wwmaxtemp | maximum temperature | uint (>=0<=80) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 929 | Proline | boiler | 122 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 930 | Proline | boiler | 122 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 931 | Proline | boiler | 122 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 932 | Proline | boiler | 122 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 933 | Proline | boiler | 122 | wwdisinfectiontemp | disinfection temperature | uint (>=60<=80) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 934 | Proline | boiler | 122 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 935 | Proline | boiler | 122 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 936 | Proline | boiler | 122 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 937 | Proline | boiler | 122 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 938 | Proline | boiler | 122 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 939 | Proline | boiler | 122 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 940 | Proline | boiler | 122 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 941 | Proline | boiler | 122 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 942 | Proline | boiler | 122 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 943 | Proline | boiler | 122 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 944 | Proline | boiler | 122 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 945 | Proline | boiler | 122 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 946 | Proline | boiler | 122 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 947 | Proline | boiler | 122 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 948 | Proline | boiler | 122 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 949 | Proline | boiler | 122 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 950 | Proline | boiler | 122 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 951 | Proline | boiler | 122 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 952 | Proline | boiler | 122 | wwstarts | starts | ulong (>=0<=16777213) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 953 | Proline | boiler | 122 | wwworkm | active time | time (>=0<=16777213) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 954 | Proline | boiler | 122 | nompower | nominal Power | uint (>=0<=254) | kW | true | number.boiler_nominal_Power | number.boiler_nompower |
| 955 | Proline | boiler | 122 | nrgtotal | total energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
| 956 | Proline | boiler | 122 | nrgheat | energy heating | ulong (>=0<=10000000) | kWh | true | number.boiler_energy_heating | number.boiler_nrgheat |
| 957 | Proline | boiler | 122 | nrgww | energy | ulong (>=0<=10000000) | kWh | true | number.boiler_energy | number.boiler_nrgww |
| 958 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 959 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 960 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 961 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 962 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 963 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 964 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 965 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 966 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 967 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 968 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 969 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 970 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 971 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 972 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 973 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 974 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 975 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 976 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 977 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 978 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 979 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 980 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burnminperiod | burner min period | uint (>=0<=120) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 981 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 982 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatblock | heating block | ushort (>=0<=3199) | C | false | sensor.boiler_heating_block | sensor.boiler_heatblock |
| 983 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | boilhyston | hysteresis on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 984 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | boilhystoff | hysteresis off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 985 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 986 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatingtemp | heating temperature | uint (>=0<=90) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 987 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 988 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 989 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 990 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 991 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | pumpdelay | pump delay | uint (>=0<=60) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 992 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 993 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 994 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 995 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 996 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burnstarts | burner starts | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 997 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 998 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 999 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 1000 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatstarts | burner starts heating | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 1001 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 1002 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 1003 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 1004 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 1005 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 1006 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 1007 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 1008 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 1009 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 1010 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 1011 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 1012 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 1013 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 1014 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 1015 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwtempecoplus | selected eco+ temperature | uint (>=0<=254) | C | true | number.boiler_selected_eco+_temperature | number.boiler_wwtempecoplus |
| 1016 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 1017 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 1018 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 1019 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 1020 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 1021 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 1022 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 1023 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 1024 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 1025 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwmaxtemp | maximum temperature | uint (>=0<=80) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 1026 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 1027 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 1028 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 1029 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 1030 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwdisinfectiontemp | disinfection temperature | uint (>=60<=80) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 1031 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 1032 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 1033 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 1034 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 1035 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 1036 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 1037 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 1038 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 1039 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 1040 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 1041 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 1042 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 1043 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 1044 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 1045 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 1046 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 1047 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 1048 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 1049 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwstarts | starts | ulong (>=0<=16777213) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 1050 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwworkm | active time | time (>=0<=16777213) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 1051 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | nompower | nominal Power | uint (>=0<=254) | kW | true | number.boiler_nominal_Power | number.boiler_nompower |
| 1052 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | nrgtotal | total energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
| 1053 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | nrgheat | energy heating | ulong (>=0<=10000000) | kWh | true | number.boiler_energy_heating | number.boiler_nrgheat |
| 1054 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | nrgww | energy | ulong (>=0<=10000000) | kWh | true | number.boiler_energy | number.boiler_nrgww |
| 1055 | GB212 | boiler | 131 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 1056 | GB212 | boiler | 131 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 1057 | GB212 | boiler | 131 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 1058 | GB212 | boiler | 131 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 1059 | GB212 | boiler | 131 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 1060 | GB212 | boiler | 131 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 1061 | GB212 | boiler | 131 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 1062 | GB212 | boiler | 131 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 1063 | GB212 | boiler | 131 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 1064 | GB212 | boiler | 131 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 1065 | GB212 | boiler | 131 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 1066 | GB212 | boiler | 131 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 1067 | GB212 | boiler | 131 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 1068 | GB212 | boiler | 131 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 1069 | GB212 | boiler | 131 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 1070 | GB212 | boiler | 131 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 1071 | GB212 | boiler | 131 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 1072 | GB212 | boiler | 131 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 1073 | GB212 | boiler | 131 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 1074 | GB212 | boiler | 131 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 1075 | GB212 | boiler | 131 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 1076 | GB212 | boiler | 131 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 1077 | GB212 | boiler | 131 | burnminperiod | burner min period | uint (>=0<=120) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 1078 | GB212 | boiler | 131 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 1079 | GB212 | boiler | 131 | heatblock | heating block | ushort (>=0<=3199) | C | false | sensor.boiler_heating_block | sensor.boiler_heatblock |
| 1080 | GB212 | boiler | 131 | boilhyston | hysteresis on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 1081 | GB212 | boiler | 131 | boilhystoff | hysteresis off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 1082 | GB212 | boiler | 131 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 1083 | GB212 | boiler | 131 | heatingtemp | heating temperature | uint (>=0<=90) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 1084 | GB212 | boiler | 131 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 1085 | GB212 | boiler | 131 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 1086 | GB212 | boiler | 131 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 1087 | GB212 | boiler | 131 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 1088 | GB212 | boiler | 131 | pumpdelay | pump delay | uint (>=0<=60) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 1089 | GB212 | boiler | 131 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 1090 | GB212 | boiler | 131 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 1091 | GB212 | boiler | 131 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 1092 | GB212 | boiler | 131 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 1093 | GB212 | boiler | 131 | burnstarts | burner starts | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 1094 | GB212 | boiler | 131 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 1095 | GB212 | boiler | 131 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 1096 | GB212 | boiler | 131 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 1097 | GB212 | boiler | 131 | heatstarts | burner starts heating | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 1098 | GB212 | boiler | 131 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 1099 | GB212 | boiler | 131 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 1100 | GB212 | boiler | 131 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 1101 | GB212 | boiler | 131 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 1102 | GB212 | boiler | 131 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 1103 | GB212 | boiler | 131 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 1104 | GB212 | boiler | 131 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 1105 | GB212 | boiler | 131 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 1106 | GB212 | boiler | 131 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 1107 | GB212 | boiler | 131 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 1108 | GB212 | boiler | 131 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 1109 | GB212 | boiler | 131 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 1110 | GB212 | boiler | 131 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 1111 | GB212 | boiler | 131 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 1112 | GB212 | boiler | 131 | wwtempecoplus | selected eco+ temperature | uint (>=0<=254) | C | true | number.boiler_selected_eco+_temperature | number.boiler_wwtempecoplus |
| 1113 | GB212 | boiler | 131 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 1114 | GB212 | boiler | 131 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 1115 | GB212 | boiler | 131 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 1116 | GB212 | boiler | 131 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 1117 | GB212 | boiler | 131 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 1118 | GB212 | boiler | 131 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 1119 | GB212 | boiler | 131 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 1120 | GB212 | boiler | 131 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 1121 | GB212 | boiler | 131 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 1122 | GB212 | boiler | 131 | wwmaxtemp | maximum temperature | uint (>=0<=80) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 1123 | GB212 | boiler | 131 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 1124 | GB212 | boiler | 131 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 1125 | GB212 | boiler | 131 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 1126 | GB212 | boiler | 131 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 1127 | GB212 | boiler | 131 | wwdisinfectiontemp | disinfection temperature | uint (>=60<=80) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 1128 | GB212 | boiler | 131 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 1129 | GB212 | boiler | 131 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 1130 | GB212 | boiler | 131 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 1131 | GB212 | boiler | 131 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 1132 | GB212 | boiler | 131 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 1133 | GB212 | boiler | 131 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 1134 | GB212 | boiler | 131 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 1135 | GB212 | boiler | 131 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 1136 | GB212 | boiler | 131 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 1137 | GB212 | boiler | 131 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 1138 | GB212 | boiler | 131 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 1139 | GB212 | boiler | 131 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 1140 | GB212 | boiler | 131 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 1141 | GB212 | boiler | 131 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 1142 | GB212 | boiler | 131 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 1143 | GB212 | boiler | 131 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 1144 | GB212 | boiler | 131 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 1145 | GB212 | boiler | 131 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 1146 | GB212 | boiler | 131 | wwstarts | starts | ulong (>=0<=16777213) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 1147 | GB212 | boiler | 131 | wwworkm | active time | time (>=0<=16777213) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 1148 | GB212 | boiler | 131 | nompower | nominal Power | uint (>=0<=254) | kW | true | number.boiler_nominal_Power | number.boiler_nompower |
| 1149 | GB212 | boiler | 131 | nrgtotal | total energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
| 1150 | GB212 | boiler | 131 | nrgheat | energy heating | ulong (>=0<=10000000) | kWh | true | number.boiler_energy_heating | number.boiler_nrgheat |
| 1151 | GB212 | boiler | 131 | nrgww | energy | ulong (>=0<=10000000) | kWh | true | number.boiler_energy | number.boiler_nrgww |
| 1152 | GC7000F | boiler | 132 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 1153 | GC7000F | boiler | 132 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 1154 | GC7000F | boiler | 132 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 1155 | GC7000F | boiler | 132 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 1156 | GC7000F | boiler | 132 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 1157 | GC7000F | boiler | 132 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 1158 | GC7000F | boiler | 132 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 1159 | GC7000F | boiler | 132 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 1160 | GC7000F | boiler | 132 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 1161 | GC7000F | boiler | 132 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 1162 | GC7000F | boiler | 132 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 1163 | GC7000F | boiler | 132 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 1164 | GC7000F | boiler | 132 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 1165 | GC7000F | boiler | 132 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 1166 | GC7000F | boiler | 132 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 1167 | GC7000F | boiler | 132 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 1168 | GC7000F | boiler | 132 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 1169 | GC7000F | boiler | 132 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 1170 | GC7000F | boiler | 132 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 1171 | GC7000F | boiler | 132 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 1172 | GC7000F | boiler | 132 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 1173 | GC7000F | boiler | 132 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 1174 | GC7000F | boiler | 132 | burnminperiod | burner min period | uint (>=0<=120) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 1175 | GC7000F | boiler | 132 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 1176 | GC7000F | boiler | 132 | heatblock | heating block | ushort (>=0<=3199) | C | false | sensor.boiler_heating_block | sensor.boiler_heatblock |
| 1177 | GC7000F | boiler | 132 | boilhyston | hysteresis on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 1178 | GC7000F | boiler | 132 | boilhystoff | hysteresis off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 1179 | GC7000F | boiler | 132 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 1180 | GC7000F | boiler | 132 | heatingtemp | heating temperature | uint (>=0<=90) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 1181 | GC7000F | boiler | 132 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 1182 | GC7000F | boiler | 132 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 1183 | GC7000F | boiler | 132 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 1184 | GC7000F | boiler | 132 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 1185 | GC7000F | boiler | 132 | pumpdelay | pump delay | uint (>=0<=60) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 1186 | GC7000F | boiler | 132 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 1187 | GC7000F | boiler | 132 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 1188 | GC7000F | boiler | 132 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 1189 | GC7000F | boiler | 132 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 1190 | GC7000F | boiler | 132 | burnstarts | burner starts | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 1191 | GC7000F | boiler | 132 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 1192 | GC7000F | boiler | 132 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 1193 | GC7000F | boiler | 132 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 1194 | GC7000F | boiler | 132 | heatstarts | burner starts heating | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 1195 | GC7000F | boiler | 132 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 1196 | GC7000F | boiler | 132 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 1197 | GC7000F | boiler | 132 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 1198 | GC7000F | boiler | 132 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 1199 | GC7000F | boiler | 132 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 1200 | GC7000F | boiler | 132 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 1201 | GC7000F | boiler | 132 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 1202 | GC7000F | boiler | 132 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 1203 | GC7000F | boiler | 132 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 1204 | GC7000F | boiler | 132 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 1205 | GC7000F | boiler | 132 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 1206 | GC7000F | boiler | 132 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 1207 | GC7000F | boiler | 132 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 1208 | GC7000F | boiler | 132 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 1209 | GC7000F | boiler | 132 | wwtempecoplus | selected eco+ temperature | uint (>=0<=254) | C | true | number.boiler_selected_eco+_temperature | number.boiler_wwtempecoplus |
| 1210 | GC7000F | boiler | 132 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 1211 | GC7000F | boiler | 132 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 1212 | GC7000F | boiler | 132 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 1213 | GC7000F | boiler | 132 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 1214 | GC7000F | boiler | 132 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 1215 | GC7000F | boiler | 132 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 1216 | GC7000F | boiler | 132 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 1217 | GC7000F | boiler | 132 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 1218 | GC7000F | boiler | 132 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 1219 | GC7000F | boiler | 132 | wwmaxtemp | maximum temperature | uint (>=0<=80) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 1220 | GC7000F | boiler | 132 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 1221 | GC7000F | boiler | 132 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 1222 | GC7000F | boiler | 132 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 1223 | GC7000F | boiler | 132 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 1224 | GC7000F | boiler | 132 | wwdisinfectiontemp | disinfection temperature | uint (>=60<=80) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 1225 | GC7000F | boiler | 132 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 1226 | GC7000F | boiler | 132 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 1227 | GC7000F | boiler | 132 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 1228 | GC7000F | boiler | 132 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 1229 | GC7000F | boiler | 132 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 1230 | GC7000F | boiler | 132 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 1231 | GC7000F | boiler | 132 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 1232 | GC7000F | boiler | 132 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 1233 | GC7000F | boiler | 132 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 1234 | GC7000F | boiler | 132 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 1235 | GC7000F | boiler | 132 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 1236 | GC7000F | boiler | 132 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 1237 | GC7000F | boiler | 132 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 1238 | GC7000F | boiler | 132 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 1239 | GC7000F | boiler | 132 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 1240 | GC7000F | boiler | 132 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 1241 | GC7000F | boiler | 132 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 1242 | GC7000F | boiler | 132 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 1243 | GC7000F | boiler | 132 | wwstarts | starts | ulong (>=0<=16777213) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 1244 | GC7000F | boiler | 132 | wwworkm | active time | time (>=0<=16777213) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 1245 | GC7000F | boiler | 132 | nompower | nominal Power | uint (>=0<=254) | kW | true | number.boiler_nominal_Power | number.boiler_nompower |
| 1246 | GC7000F | boiler | 132 | nrgtotal | total energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
| 1247 | GC7000F | boiler | 132 | nrgheat | energy heating | ulong (>=0<=10000000) | kWh | true | number.boiler_energy_heating | number.boiler_nrgheat |
| 1248 | GC7000F | boiler | 132 | nrgww | energy | ulong (>=0<=10000000) | kWh | true | number.boiler_energy | number.boiler_nrgww |
| 1249 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 1250 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 1251 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 1252 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 1253 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 1254 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 1255 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 1256 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 1257 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 1258 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 1259 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 1260 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 1261 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 1262 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 1263 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 1264 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 1265 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 1266 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 1267 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 1268 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 1269 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 1270 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 1271 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burnminperiod | burner min period | uint (>=0<=120) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 1272 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 1273 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatblock | heating block | ushort (>=0<=3199) | C | false | sensor.boiler_heating_block | sensor.boiler_heatblock |
| 1274 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | boilhyston | hysteresis on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 1275 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | boilhystoff | hysteresis off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 1276 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 1277 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatingtemp | heating temperature | uint (>=0<=90) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 1278 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 1279 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 1280 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 1281 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 1282 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | pumpdelay | pump delay | uint (>=0<=60) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 1283 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 1284 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 1285 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 1286 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 1287 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burnstarts | burner starts | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 1288 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 1289 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 1290 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 1291 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatstarts | burner starts heating | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 1292 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 1293 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 1294 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 1295 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 1296 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 1297 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 1298 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 1299 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 1300 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 1301 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 1302 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 1303 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 1304 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 1305 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 1306 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwtempecoplus | selected eco+ temperature | uint (>=0<=254) | C | true | number.boiler_selected_eco+_temperature | number.boiler_wwtempecoplus |
| 1307 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 1308 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 1309 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 1310 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 1311 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 1312 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 1313 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 1314 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 1315 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 1316 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwmaxtemp | maximum temperature | uint (>=0<=80) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 1317 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 1318 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 1319 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 1320 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 1321 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwdisinfectiontemp | disinfection temperature | uint (>=60<=80) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 1322 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 1323 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 1324 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 1325 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 1326 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 1327 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 1328 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 1329 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 1330 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 1331 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 1332 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 1333 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 1334 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 1335 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 1336 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 1337 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 1338 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 1339 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 1340 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwstarts | starts | ulong (>=0<=16777213) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 1341 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwworkm | active time | time (>=0<=16777213) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 1342 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | nompower | nominal Power | uint (>=0<=254) | kW | true | number.boiler_nominal_Power | number.boiler_nompower |
| 1343 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | nrgtotal | total energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
| 1344 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | nrgheat | energy heating | ulong (>=0<=10000000) | kWh | true | number.boiler_energy_heating | number.boiler_nrgheat |
| 1345 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | nrgww | energy | ulong (>=0<=10000000) | kWh | true | number.boiler_energy | number.boiler_nrgww |
| 1346 | Greenstar 30Ri Compact | boiler | 154 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 1347 | Greenstar 30Ri Compact | boiler | 154 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 1348 | Greenstar 30Ri Compact | boiler | 154 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 1349 | Greenstar 30Ri Compact | boiler | 154 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 1350 | Greenstar 30Ri Compact | boiler | 154 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 1351 | Greenstar 30Ri Compact | boiler | 154 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 1352 | Greenstar 30Ri Compact | boiler | 154 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 1353 | Greenstar 30Ri Compact | boiler | 154 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 1354 | Greenstar 30Ri Compact | boiler | 154 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 1355 | Greenstar 30Ri Compact | boiler | 154 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 1356 | Greenstar 30Ri Compact | boiler | 154 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 1357 | Greenstar 30Ri Compact | boiler | 154 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 1358 | Greenstar 30Ri Compact | boiler | 154 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 1359 | Greenstar 30Ri Compact | boiler | 154 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 1360 | Greenstar 30Ri Compact | boiler | 154 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 1361 | Greenstar 30Ri Compact | boiler | 154 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 1362 | Greenstar 30Ri Compact | boiler | 154 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 1363 | Greenstar 30Ri Compact | boiler | 154 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 1364 | Greenstar 30Ri Compact | boiler | 154 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 1365 | Greenstar 30Ri Compact | boiler | 154 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 1366 | Greenstar 30Ri Compact | boiler | 154 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 1367 | Greenstar 30Ri Compact | boiler | 154 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 1368 | Greenstar 30Ri Compact | boiler | 154 | burnminperiod | burner min period | uint (>=0<=120) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 1369 | Greenstar 30Ri Compact | boiler | 154 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 1370 | Greenstar 30Ri Compact | boiler | 154 | heatblock | heating block | ushort (>=0<=3199) | C | false | sensor.boiler_heating_block | sensor.boiler_heatblock |
| 1371 | Greenstar 30Ri Compact | boiler | 154 | boilhyston | hysteresis on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 1372 | Greenstar 30Ri Compact | boiler | 154 | boilhystoff | hysteresis off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 1373 | Greenstar 30Ri Compact | boiler | 154 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 1374 | Greenstar 30Ri Compact | boiler | 154 | heatingtemp | heating temperature | uint (>=0<=90) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 1375 | Greenstar 30Ri Compact | boiler | 154 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 1376 | Greenstar 30Ri Compact | boiler | 154 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 1377 | Greenstar 30Ri Compact | boiler | 154 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 1378 | Greenstar 30Ri Compact | boiler | 154 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 1379 | Greenstar 30Ri Compact | boiler | 154 | pumpdelay | pump delay | uint (>=0<=60) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 1380 | Greenstar 30Ri Compact | boiler | 154 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 1381 | Greenstar 30Ri Compact | boiler | 154 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 1382 | Greenstar 30Ri Compact | boiler | 154 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 1383 | Greenstar 30Ri Compact | boiler | 154 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 1384 | Greenstar 30Ri Compact | boiler | 154 | burnstarts | burner starts | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 1385 | Greenstar 30Ri Compact | boiler | 154 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 1386 | Greenstar 30Ri Compact | boiler | 154 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 1387 | Greenstar 30Ri Compact | boiler | 154 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 1388 | Greenstar 30Ri Compact | boiler | 154 | heatstarts | burner starts heating | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 1389 | Greenstar 30Ri Compact | boiler | 154 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 1390 | Greenstar 30Ri Compact | boiler | 154 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 1391 | Greenstar 30Ri Compact | boiler | 154 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 1392 | Greenstar 30Ri Compact | boiler | 154 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 1393 | Greenstar 30Ri Compact | boiler | 154 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 1394 | Greenstar 30Ri Compact | boiler | 154 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 1395 | Greenstar 30Ri Compact | boiler | 154 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 1396 | Greenstar 30Ri Compact | boiler | 154 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 1397 | Greenstar 30Ri Compact | boiler | 154 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 1398 | Greenstar 30Ri Compact | boiler | 154 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 1399 | Greenstar 30Ri Compact | boiler | 154 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 1400 | Greenstar 30Ri Compact | boiler | 154 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 1401 | Greenstar 30Ri Compact | boiler | 154 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 1402 | Greenstar 30Ri Compact | boiler | 154 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 1403 | Greenstar 30Ri Compact | boiler | 154 | wwtempecoplus | selected eco+ temperature | uint (>=0<=254) | C | true | number.boiler_selected_eco+_temperature | number.boiler_wwtempecoplus |
| 1404 | Greenstar 30Ri Compact | boiler | 154 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 1405 | Greenstar 30Ri Compact | boiler | 154 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 1406 | Greenstar 30Ri Compact | boiler | 154 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 1407 | Greenstar 30Ri Compact | boiler | 154 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 1408 | Greenstar 30Ri Compact | boiler | 154 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 1409 | Greenstar 30Ri Compact | boiler | 154 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 1410 | Greenstar 30Ri Compact | boiler | 154 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 1411 | Greenstar 30Ri Compact | boiler | 154 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 1412 | Greenstar 30Ri Compact | boiler | 154 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 1413 | Greenstar 30Ri Compact | boiler | 154 | wwmaxtemp | maximum temperature | uint (>=0<=80) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 1414 | Greenstar 30Ri Compact | boiler | 154 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 1415 | Greenstar 30Ri Compact | boiler | 154 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 1416 | Greenstar 30Ri Compact | boiler | 154 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 1417 | Greenstar 30Ri Compact | boiler | 154 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 1418 | Greenstar 30Ri Compact | boiler | 154 | wwdisinfectiontemp | disinfection temperature | uint (>=60<=80) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 1419 | Greenstar 30Ri Compact | boiler | 154 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 1420 | Greenstar 30Ri Compact | boiler | 154 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 1421 | Greenstar 30Ri Compact | boiler | 154 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 1422 | Greenstar 30Ri Compact | boiler | 154 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 1423 | Greenstar 30Ri Compact | boiler | 154 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 1424 | Greenstar 30Ri Compact | boiler | 154 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 1425 | Greenstar 30Ri Compact | boiler | 154 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 1426 | Greenstar 30Ri Compact | boiler | 154 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 1427 | Greenstar 30Ri Compact | boiler | 154 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 1428 | Greenstar 30Ri Compact | boiler | 154 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 1429 | Greenstar 30Ri Compact | boiler | 154 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 1430 | Greenstar 30Ri Compact | boiler | 154 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 1431 | Greenstar 30Ri Compact | boiler | 154 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 1432 | Greenstar 30Ri Compact | boiler | 154 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 1433 | Greenstar 30Ri Compact | boiler | 154 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 1434 | Greenstar 30Ri Compact | boiler | 154 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 1435 | Greenstar 30Ri Compact | boiler | 154 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 1436 | Greenstar 30Ri Compact | boiler | 154 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 1437 | Greenstar 30Ri Compact | boiler | 154 | wwstarts | starts | ulong (>=0<=16777213) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 1438 | Greenstar 30Ri Compact | boiler | 154 | wwworkm | active time | time (>=0<=16777213) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 1439 | Greenstar 30Ri Compact | boiler | 154 | nompower | nominal Power | uint (>=0<=254) | kW | true | number.boiler_nominal_Power | number.boiler_nompower |
| 1440 | Greenstar 30Ri Compact | boiler | 154 | nrgtotal | total energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
| 1441 | Greenstar 30Ri Compact | boiler | 154 | nrgheat | energy heating | ulong (>=0<=10000000) | kWh | true | number.boiler_energy_heating | number.boiler_nrgheat |
| 1442 | Greenstar 30Ri Compact | boiler | 154 | nrgww | energy | ulong (>=0<=10000000) | kWh | true | number.boiler_energy | number.boiler_nrgww |
| 1443 | Cerapur Aero | boiler | 167 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 1444 | Cerapur Aero | boiler | 167 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 1445 | Cerapur Aero | boiler | 167 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 1446 | Cerapur Aero | boiler | 167 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 1447 | Cerapur Aero | boiler | 167 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 1448 | Cerapur Aero | boiler | 167 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 1449 | Cerapur Aero | boiler | 167 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 1450 | Cerapur Aero | boiler | 167 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 1451 | Cerapur Aero | boiler | 167 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 1452 | Cerapur Aero | boiler | 167 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 1453 | Cerapur Aero | boiler | 167 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 1454 | Cerapur Aero | boiler | 167 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 1455 | Cerapur Aero | boiler | 167 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 1456 | Cerapur Aero | boiler | 167 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 1457 | Cerapur Aero | boiler | 167 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 1458 | Cerapur Aero | boiler | 167 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 1459 | Cerapur Aero | boiler | 167 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 1460 | Cerapur Aero | boiler | 167 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 1461 | Cerapur Aero | boiler | 167 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 1462 | Cerapur Aero | boiler | 167 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 1463 | Cerapur Aero | boiler | 167 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 1464 | Cerapur Aero | boiler | 167 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 1465 | Cerapur Aero | boiler | 167 | burnminperiod | burner min period | uint (>=0<=120) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 1466 | Cerapur Aero | boiler | 167 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 1467 | Cerapur Aero | boiler | 167 | heatblock | heating block | ushort (>=0<=3199) | C | false | sensor.boiler_heating_block | sensor.boiler_heatblock |
| 1468 | Cerapur Aero | boiler | 167 | boilhyston | hysteresis on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 1469 | Cerapur Aero | boiler | 167 | boilhystoff | hysteresis off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 1470 | Cerapur Aero | boiler | 167 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 1471 | Cerapur Aero | boiler | 167 | heatingtemp | heating temperature | uint (>=0<=90) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 1472 | Cerapur Aero | boiler | 167 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 1473 | Cerapur Aero | boiler | 167 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 1474 | Cerapur Aero | boiler | 167 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 1475 | Cerapur Aero | boiler | 167 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 1476 | Cerapur Aero | boiler | 167 | pumpdelay | pump delay | uint (>=0<=60) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 1477 | Cerapur Aero | boiler | 167 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 1478 | Cerapur Aero | boiler | 167 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 1479 | Cerapur Aero | boiler | 167 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 1480 | Cerapur Aero | boiler | 167 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 1481 | Cerapur Aero | boiler | 167 | burnstarts | burner starts | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 1482 | Cerapur Aero | boiler | 167 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 1483 | Cerapur Aero | boiler | 167 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 1484 | Cerapur Aero | boiler | 167 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 1485 | Cerapur Aero | boiler | 167 | heatstarts | burner starts heating | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 1486 | Cerapur Aero | boiler | 167 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 1487 | Cerapur Aero | boiler | 167 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 1488 | Cerapur Aero | boiler | 167 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 1489 | Cerapur Aero | boiler | 167 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 1490 | Cerapur Aero | boiler | 167 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 1491 | Cerapur Aero | boiler | 167 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 1492 | Cerapur Aero | boiler | 167 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 1493 | Cerapur Aero | boiler | 167 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 1494 | Cerapur Aero | boiler | 167 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 1495 | Cerapur Aero | boiler | 167 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 1496 | Cerapur Aero | boiler | 167 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 1497 | Cerapur Aero | boiler | 167 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 1498 | Cerapur Aero | boiler | 167 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 1499 | Cerapur Aero | boiler | 167 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 1500 | Cerapur Aero | boiler | 167 | wwtempecoplus | selected eco+ temperature | uint (>=0<=254) | C | true | number.boiler_selected_eco+_temperature | number.boiler_wwtempecoplus |
| 1501 | Cerapur Aero | boiler | 167 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 1502 | Cerapur Aero | boiler | 167 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 1503 | Cerapur Aero | boiler | 167 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 1504 | Cerapur Aero | boiler | 167 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 1505 | Cerapur Aero | boiler | 167 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 1506 | Cerapur Aero | boiler | 167 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 1507 | Cerapur Aero | boiler | 167 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 1508 | Cerapur Aero | boiler | 167 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 1509 | Cerapur Aero | boiler | 167 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 1510 | Cerapur Aero | boiler | 167 | wwmaxtemp | maximum temperature | uint (>=0<=80) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 1511 | Cerapur Aero | boiler | 167 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 1512 | Cerapur Aero | boiler | 167 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 1513 | Cerapur Aero | boiler | 167 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 1514 | Cerapur Aero | boiler | 167 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 1515 | Cerapur Aero | boiler | 167 | wwdisinfectiontemp | disinfection temperature | uint (>=60<=80) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 1516 | Cerapur Aero | boiler | 167 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 1517 | Cerapur Aero | boiler | 167 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 1518 | Cerapur Aero | boiler | 167 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 1519 | Cerapur Aero | boiler | 167 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 1520 | Cerapur Aero | boiler | 167 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 1521 | Cerapur Aero | boiler | 167 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 1522 | Cerapur Aero | boiler | 167 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 1523 | Cerapur Aero | boiler | 167 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 1524 | Cerapur Aero | boiler | 167 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 1525 | Cerapur Aero | boiler | 167 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 1526 | Cerapur Aero | boiler | 167 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 1527 | Cerapur Aero | boiler | 167 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 1528 | Cerapur Aero | boiler | 167 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 1529 | Cerapur Aero | boiler | 167 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 1530 | Cerapur Aero | boiler | 167 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 1531 | Cerapur Aero | boiler | 167 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 1532 | Cerapur Aero | boiler | 167 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 1533 | Cerapur Aero | boiler | 167 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 1534 | Cerapur Aero | boiler | 167 | wwstarts | starts | ulong (>=0<=16777213) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 1535 | Cerapur Aero | boiler | 167 | wwworkm | active time | time (>=0<=16777213) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 1536 | Cerapur Aero | boiler | 167 | nompower | nominal Power | uint (>=0<=254) | kW | true | number.boiler_nominal_Power | number.boiler_nompower |
| 1537 | Cerapur Aero | boiler | 167 | nrgtotal | total energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
| 1538 | Cerapur Aero | boiler | 167 | nrgheat | energy heating | ulong (>=0<=10000000) | kWh | true | number.boiler_energy_heating | number.boiler_nrgheat |
| 1539 | Cerapur Aero | boiler | 167 | nrgww | energy | ulong (>=0<=10000000) | kWh | true | number.boiler_energy | number.boiler_nrgww |
| 1540 | Hybrid Heatpump | boiler | 168 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 1541 | Hybrid Heatpump | boiler | 168 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 1542 | Hybrid Heatpump | boiler | 168 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 1543 | Hybrid Heatpump | boiler | 168 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 1544 | Hybrid Heatpump | boiler | 168 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 1545 | Hybrid Heatpump | boiler | 168 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 1546 | Hybrid Heatpump | boiler | 168 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 1547 | Hybrid Heatpump | boiler | 168 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 1548 | Hybrid Heatpump | boiler | 168 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 1549 | Hybrid Heatpump | boiler | 168 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 1550 | Hybrid Heatpump | boiler | 168 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 1551 | Hybrid Heatpump | boiler | 168 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 1552 | Hybrid Heatpump | boiler | 168 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 1553 | Hybrid Heatpump | boiler | 168 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 1554 | Hybrid Heatpump | boiler | 168 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 1555 | Hybrid Heatpump | boiler | 168 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 1556 | Hybrid Heatpump | boiler | 168 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 1557 | Hybrid Heatpump | boiler | 168 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 1558 | Hybrid Heatpump | boiler | 168 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 1559 | Hybrid Heatpump | boiler | 168 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 1560 | Hybrid Heatpump | boiler | 168 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 1561 | Hybrid Heatpump | boiler | 168 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 1562 | Hybrid Heatpump | boiler | 168 | burnminperiod | burner min period | uint (>=0<=120) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 1563 | Hybrid Heatpump | boiler | 168 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 1564 | Hybrid Heatpump | boiler | 168 | heatblock | heating block | ushort (>=0<=3199) | C | false | sensor.boiler_heating_block | sensor.boiler_heatblock |
| 1565 | Hybrid Heatpump | boiler | 168 | boilhyston | hysteresis on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 1566 | Hybrid Heatpump | boiler | 168 | boilhystoff | hysteresis off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 1567 | Hybrid Heatpump | boiler | 168 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 1568 | Hybrid Heatpump | boiler | 168 | heatingtemp | heating temperature | uint (>=0<=90) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 1569 | Hybrid Heatpump | boiler | 168 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 1570 | Hybrid Heatpump | boiler | 168 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 1571 | Hybrid Heatpump | boiler | 168 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 1572 | Hybrid Heatpump | boiler | 168 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 1573 | Hybrid Heatpump | boiler | 168 | pumpdelay | pump delay | uint (>=0<=60) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 1574 | Hybrid Heatpump | boiler | 168 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 1575 | Hybrid Heatpump | boiler | 168 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 1576 | Hybrid Heatpump | boiler | 168 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 1577 | Hybrid Heatpump | boiler | 168 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 1578 | Hybrid Heatpump | boiler | 168 | burnstarts | burner starts | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 1579 | Hybrid Heatpump | boiler | 168 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 1580 | Hybrid Heatpump | boiler | 168 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 1581 | Hybrid Heatpump | boiler | 168 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 1582 | Hybrid Heatpump | boiler | 168 | heatstarts | burner starts heating | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 1583 | Hybrid Heatpump | boiler | 168 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 1584 | Hybrid Heatpump | boiler | 168 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 1585 | Hybrid Heatpump | boiler | 168 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 1586 | Hybrid Heatpump | boiler | 168 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 1587 | Hybrid Heatpump | boiler | 168 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 1588 | Hybrid Heatpump | boiler | 168 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 1589 | Hybrid Heatpump | boiler | 168 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 1590 | Hybrid Heatpump | boiler | 168 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 1591 | Hybrid Heatpump | boiler | 168 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 1592 | Hybrid Heatpump | boiler | 168 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 1593 | Hybrid Heatpump | boiler | 168 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 1594 | Hybrid Heatpump | boiler | 168 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 1595 | Hybrid Heatpump | boiler | 168 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 1596 | Hybrid Heatpump | boiler | 168 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 1597 | Hybrid Heatpump | boiler | 168 | wwtempecoplus | selected eco+ temperature | uint (>=0<=254) | C | true | number.boiler_selected_eco+_temperature | number.boiler_wwtempecoplus |
| 1598 | Hybrid Heatpump | boiler | 168 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 1599 | Hybrid Heatpump | boiler | 168 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 1600 | Hybrid Heatpump | boiler | 168 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 1601 | Hybrid Heatpump | boiler | 168 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 1602 | Hybrid Heatpump | boiler | 168 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 1603 | Hybrid Heatpump | boiler | 168 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 1604 | Hybrid Heatpump | boiler | 168 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 1605 | Hybrid Heatpump | boiler | 168 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 1606 | Hybrid Heatpump | boiler | 168 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 1607 | Hybrid Heatpump | boiler | 168 | wwmaxtemp | maximum temperature | uint (>=0<=80) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 1608 | Hybrid Heatpump | boiler | 168 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 1609 | Hybrid Heatpump | boiler | 168 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 1610 | Hybrid Heatpump | boiler | 168 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 1611 | Hybrid Heatpump | boiler | 168 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 1612 | Hybrid Heatpump | boiler | 168 | wwdisinfectiontemp | disinfection temperature | uint (>=60<=80) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 1613 | Hybrid Heatpump | boiler | 168 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 1614 | Hybrid Heatpump | boiler | 168 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 1615 | Hybrid Heatpump | boiler | 168 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 1616 | Hybrid Heatpump | boiler | 168 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 1617 | Hybrid Heatpump | boiler | 168 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 1618 | Hybrid Heatpump | boiler | 168 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 1619 | Hybrid Heatpump | boiler | 168 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 1620 | Hybrid Heatpump | boiler | 168 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 1621 | Hybrid Heatpump | boiler | 168 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 1622 | Hybrid Heatpump | boiler | 168 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 1623 | Hybrid Heatpump | boiler | 168 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 1624 | Hybrid Heatpump | boiler | 168 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 1625 | Hybrid Heatpump | boiler | 168 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 1626 | Hybrid Heatpump | boiler | 168 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 1627 | Hybrid Heatpump | boiler | 168 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 1628 | Hybrid Heatpump | boiler | 168 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 1629 | Hybrid Heatpump | boiler | 168 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 1630 | Hybrid Heatpump | boiler | 168 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 1631 | Hybrid Heatpump | boiler | 168 | wwstarts | starts | ulong (>=0<=16777213) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 1632 | Hybrid Heatpump | boiler | 168 | wwworkm | active time | time (>=0<=16777213) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 1633 | Hybrid Heatpump | boiler | 168 | nompower | nominal Power | uint (>=0<=254) | kW | true | number.boiler_nominal_Power | number.boiler_nompower |
| 1634 | Hybrid Heatpump | boiler | 168 | nrgtotal | total energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
| 1635 | Hybrid Heatpump | boiler | 168 | nrgheat | energy heating | ulong (>=0<=10000000) | kWh | true | number.boiler_energy_heating | number.boiler_nrgheat |
| 1636 | Hybrid Heatpump | boiler | 168 | nrgww | energy | ulong (>=0<=10000000) | kWh | true | number.boiler_energy | number.boiler_nrgww |
| 1637 | Logano GB212 | boiler | 170 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 1638 | Logano GB212 | boiler | 170 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 1639 | Logano GB212 | boiler | 170 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 1640 | Logano GB212 | boiler | 170 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 1641 | Logano GB212 | boiler | 170 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 1642 | Logano GB212 | boiler | 170 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 1643 | Logano GB212 | boiler | 170 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 1644 | Logano GB212 | boiler | 170 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 1645 | Logano GB212 | boiler | 170 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 1646 | Logano GB212 | boiler | 170 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 1647 | Logano GB212 | boiler | 170 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 1648 | Logano GB212 | boiler | 170 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 1649 | Logano GB212 | boiler | 170 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 1650 | Logano GB212 | boiler | 170 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 1651 | Logano GB212 | boiler | 170 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 1652 | Logano GB212 | boiler | 170 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 1653 | Logano GB212 | boiler | 170 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 1654 | Logano GB212 | boiler | 170 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 1655 | Logano GB212 | boiler | 170 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 1656 | Logano GB212 | boiler | 170 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 1657 | Logano GB212 | boiler | 170 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 1658 | Logano GB212 | boiler | 170 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 1659 | Logano GB212 | boiler | 170 | burnminperiod | burner min period | uint (>=0<=120) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 1660 | Logano GB212 | boiler | 170 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 1661 | Logano GB212 | boiler | 170 | heatblock | heating block | ushort (>=0<=3199) | C | false | sensor.boiler_heating_block | sensor.boiler_heatblock |
| 1662 | Logano GB212 | boiler | 170 | boilhyston | hysteresis on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 1663 | Logano GB212 | boiler | 170 | boilhystoff | hysteresis off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 1664 | Logano GB212 | boiler | 170 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 1665 | Logano GB212 | boiler | 170 | heatingtemp | heating temperature | uint (>=0<=90) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 1666 | Logano GB212 | boiler | 170 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 1667 | Logano GB212 | boiler | 170 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 1668 | Logano GB212 | boiler | 170 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 1669 | Logano GB212 | boiler | 170 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 1670 | Logano GB212 | boiler | 170 | pumpdelay | pump delay | uint (>=0<=60) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 1671 | Logano GB212 | boiler | 170 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 1672 | Logano GB212 | boiler | 170 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 1673 | Logano GB212 | boiler | 170 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 1674 | Logano GB212 | boiler | 170 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 1675 | Logano GB212 | boiler | 170 | burnstarts | burner starts | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 1676 | Logano GB212 | boiler | 170 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 1677 | Logano GB212 | boiler | 170 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 1678 | Logano GB212 | boiler | 170 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 1679 | Logano GB212 | boiler | 170 | heatstarts | burner starts heating | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 1680 | Logano GB212 | boiler | 170 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 1681 | Logano GB212 | boiler | 170 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 1682 | Logano GB212 | boiler | 170 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 1683 | Logano GB212 | boiler | 170 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 1684 | Logano GB212 | boiler | 170 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 1685 | Logano GB212 | boiler | 170 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 1686 | Logano GB212 | boiler | 170 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 1687 | Logano GB212 | boiler | 170 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 1688 | Logano GB212 | boiler | 170 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 1689 | Logano GB212 | boiler | 170 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 1690 | Logano GB212 | boiler | 170 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 1691 | Logano GB212 | boiler | 170 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 1692 | Logano GB212 | boiler | 170 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 1693 | Logano GB212 | boiler | 170 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 1694 | Logano GB212 | boiler | 170 | wwtempecoplus | selected eco+ temperature | uint (>=0<=254) | C | true | number.boiler_selected_eco+_temperature | number.boiler_wwtempecoplus |
| 1695 | Logano GB212 | boiler | 170 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 1696 | Logano GB212 | boiler | 170 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 1697 | Logano GB212 | boiler | 170 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 1698 | Logano GB212 | boiler | 170 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 1699 | Logano GB212 | boiler | 170 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 1700 | Logano GB212 | boiler | 170 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 1701 | Logano GB212 | boiler | 170 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 1702 | Logano GB212 | boiler | 170 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 1703 | Logano GB212 | boiler | 170 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 1704 | Logano GB212 | boiler | 170 | wwmaxtemp | maximum temperature | uint (>=0<=80) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 1705 | Logano GB212 | boiler | 170 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 1706 | Logano GB212 | boiler | 170 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 1707 | Logano GB212 | boiler | 170 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 1708 | Logano GB212 | boiler | 170 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 1709 | Logano GB212 | boiler | 170 | wwdisinfectiontemp | disinfection temperature | uint (>=60<=80) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 1710 | Logano GB212 | boiler | 170 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 1711 | Logano GB212 | boiler | 170 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 1712 | Logano GB212 | boiler | 170 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 1713 | Logano GB212 | boiler | 170 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 1714 | Logano GB212 | boiler | 170 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 1715 | Logano GB212 | boiler | 170 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 1716 | Logano GB212 | boiler | 170 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 1717 | Logano GB212 | boiler | 170 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 1718 | Logano GB212 | boiler | 170 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 1719 | Logano GB212 | boiler | 170 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 1720 | Logano GB212 | boiler | 170 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 1721 | Logano GB212 | boiler | 170 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 1722 | Logano GB212 | boiler | 170 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 1723 | Logano GB212 | boiler | 170 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 1724 | Logano GB212 | boiler | 170 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 1725 | Logano GB212 | boiler | 170 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 1726 | Logano GB212 | boiler | 170 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 1727 | Logano GB212 | boiler | 170 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 1728 | Logano GB212 | boiler | 170 | wwstarts | starts | ulong (>=0<=16777213) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 1729 | Logano GB212 | boiler | 170 | wwworkm | active time | time (>=0<=16777213) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 1730 | Logano GB212 | boiler | 170 | nompower | nominal Power | uint (>=0<=254) | kW | true | number.boiler_nominal_Power | number.boiler_nompower |
| 1731 | Logano GB212 | boiler | 170 | nrgtotal | total energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
| 1732 | Logano GB212 | boiler | 170 | nrgheat | energy heating | ulong (>=0<=10000000) | kWh | true | number.boiler_energy_heating | number.boiler_nrgheat |
| 1733 | Logano GB212 | boiler | 170 | nrgww | energy | ulong (>=0<=10000000) | kWh | true | number.boiler_energy | number.boiler_nrgww |
| 1734 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 1735 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 1736 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 1737 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 1738 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 1739 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 1740 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 1741 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 1742 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 1743 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 1744 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 1745 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 1746 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 1747 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 1748 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingtemp | heating temperature | uint (>=0<=90) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 1749 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 1750 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 1751 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 1752 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 1753 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | pumpdelay | pump delay | uint (>=0<=60) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 1754 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 1755 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 1756 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 1757 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 1758 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | burnstarts | burner starts | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 1759 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 1760 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 1761 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 1762 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatstarts | burner starts heating | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 1763 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 1764 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 1765 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 1766 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 1767 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 1768 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 1769 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 1770 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 1771 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 1772 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 1773 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgtotal | total energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
| 1774 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgww | energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_energy | sensor.boiler_nrgww |
| 1775 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgheat | energy heating | ulong (>=0<=167772) | kWh | false | sensor.boiler_energy_heating | sensor.boiler_nrgheat |
| 1776 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | metertotal | meter total | ulong (>=0<=167772) | kWh | false | sensor.boiler_meter_total | sensor.boiler_metertotal |
| 1777 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | metercomp | meter compressor | ulong (>=0<=167772) | kWh | false | sensor.boiler_meter_compressor | sensor.boiler_metercomp |
| 1778 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | metereheat | meter e-heater | ulong (>=0<=167772) | kWh | false | sensor.boiler_meter_e-heater | sensor.boiler_metereheat |
| 1779 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | uptimetotal | heatpump total uptime | time (>=0<=279620) | minutes | false | sensor.boiler_heatpump_total_uptime | sensor.boiler_uptimetotal |
| 1780 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | uptimecontrol | total operating time heat | time (>=0<=279620) | minutes | false | sensor.boiler_total_operating_time_heat | sensor.boiler_uptimecontrol |
| 1781 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | uptimecompheating | operating time compressor heating | time (>=0<=279620) | minutes | false | sensor.boiler_operating_time_compressor_heating | sensor.boiler_uptimecompheating |
| 1782 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | uptimecompcooling | operating time compressor cooling | time (>=0<=279620) | minutes | false | sensor.boiler_operating_time_compressor_cooling | sensor.boiler_uptimecompcooling |
| 1783 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | uptimecompww | operating time compressor | time (>=0<=279620) | minutes | false | sensor.boiler_operating_time_compressor | sensor.boiler_uptimecompww |
| 1784 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | uptimecomppool | operating time compressor pool | time (>=0<=279620) | minutes | false | sensor.boiler_operating_time_compressor_pool | sensor.boiler_uptimecomppool |
| 1785 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | totalcompstarts | total compressor control starts | ulong (>=0<=16777213) | false | sensor.boiler_total_compressor_control_starts | sensor.boiler_totalcompstarts | |
| 1786 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingstarts | heating control starts | ulong (>=0<=16777213) | false | sensor.boiler_heating_control_starts | sensor.boiler_heatingstarts | |
| 1787 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | coolingstarts | cooling control starts | ulong (>=0<=16777213) | false | sensor.boiler_cooling_control_starts | sensor.boiler_coolingstarts | |
| 1788 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwstarts2 | control starts2 | ulong (>=0<=16777213) | false | sensor.boiler_control_starts2 | sensor.boiler_wwstarts2 | |
| 1789 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | poolstarts | pool control starts | ulong (>=0<=16777213) | false | sensor.boiler_pool_control_starts | sensor.boiler_poolstarts | |
| 1790 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconstotal | total energy consumption | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_energy_consumption | sensor.boiler_nrgconstotal |
| 1791 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconscomptotal | total energy consumption compressor | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_energy_consumption_compressor | sensor.boiler_nrgconscomptotal |
| 1792 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconscompheating | energy consumption compressor heating | ulong (>=0<=16777213) | kWh | false | sensor.boiler_energy_consumption_compressor_heating | sensor.boiler_nrgconscompheating |
| 1793 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconscompww | energy consumption compressor | ulong (>=0<=16777213) | kWh | false | sensor.boiler_energy_consumption_compressor | sensor.boiler_nrgconscompww |
| 1794 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconscompcooling | energy consumption compressor cooling | ulong (>=0<=16777213) | kWh | false | sensor.boiler_energy_consumption_compressor_cooling | sensor.boiler_nrgconscompcooling |
| 1795 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconscomppool | energy consumption compressor pool | ulong (>=0<=16777213) | kWh | false | sensor.boiler_energy_consumption_compressor_pool | sensor.boiler_nrgconscomppool |
| 1796 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxelecheatnrgconstotal | total aux elec. heater energy consumption | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_aux_elec._heater_energy_consumption | sensor.boiler_auxelecheatnrgconstotal |
| 1797 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxelecheatnrgconsheating | aux elec. heater energy consumption heating | ulong (>=0<=16777213) | kWh | false | sensor.boiler_aux_elec._heater_energy_consumption_heating | sensor.boiler_auxelecheatnrgconsheating |
| 1798 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxelecheatnrgconsww | aux elec. heater energy consumption | ulong (>=0<=16777213) | kWh | false | sensor.boiler_aux_elec._heater_energy_consumption | sensor.boiler_auxelecheatnrgconsww |
| 1799 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxelecheatnrgconspool | aux elec. heater energy consumption pool | ulong (>=0<=16777213) | kWh | false | sensor.boiler_aux_elec._heater_energy_consumption_pool | sensor.boiler_auxelecheatnrgconspool |
| 1800 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgsupptotal | total energy supplied | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_energy_supplied | sensor.boiler_nrgsupptotal |
| 1801 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgsuppheating | total energy supplied heating | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_energy_supplied_heating | sensor.boiler_nrgsuppheating |
| 1802 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgsuppww | total energy warm supplied | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_energy_warm_supplied | sensor.boiler_nrgsuppww |
| 1803 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgsuppcooling | total energy supplied cooling | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_energy_supplied_cooling | sensor.boiler_nrgsuppcooling |
| 1804 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgsupppool | total energy supplied pool | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_energy_supplied_pool | sensor.boiler_nrgsupppool |
| 1805 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hppower | compressor power output | uint (>=0<=25) | kW | false | sensor.boiler_compressor_power_output | sensor.boiler_hppower |
| 1806 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpcompon | hp compressor | boolean | false | binary_sensor.boiler_hp_compressor | binary_sensor.boiler_hpcompon | |
| 1807 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpactivity | compressor activity | enum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost] | false | sensor.boiler_compressor_activity | sensor.boiler_hpactivity | |
| 1808 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpbrinepumpspd | brine pump speed | uint (>=0<=100) | % | false | sensor.boiler_brine_pump_speed | sensor.boiler_hpbrinepumpspd |
| 1809 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpswitchvalve | switch valve | boolean | false | binary_sensor.boiler_switch_valve | binary_sensor.boiler_hpswitchvalve | |
| 1810 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpcompspd | compressor speed | uint (>=0<=100) | % | false | sensor.boiler_compressor_speed | sensor.boiler_hpcompspd |
| 1811 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpcircspd | circulation pump speed | uint (>=0<=100) | % | false | sensor.boiler_circulation_pump_speed | sensor.boiler_hpcircspd |
| 1812 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpbrinein | brine in/evaporator | short (>=-3199<=3199) | C | false | sensor.boiler_brine_in/evaporator | sensor.boiler_hpbrinein |
| 1813 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpbrineout | brine out/condenser | short (>=-3199<=3199) | C | false | sensor.boiler_brine_out/condenser | sensor.boiler_hpbrineout |
| 1814 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptc0 | heat carrier return (TC0) | short (>=-3199<=3199) | C | false | sensor.boiler_heat_carrier_return_(TC0) | sensor.boiler_hptc0 |
| 1815 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptc1 | heat carrier forward (TC1) | short (>=-3199<=3199) | C | false | sensor.boiler_heat_carrier_forward_(TC1) | sensor.boiler_hptc1 |
| 1816 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptc3 | condenser temperature (TC3) | short (>=-3199<=3199) | C | false | sensor.boiler_condenser_temperature_(TC3) | sensor.boiler_hptc3 |
| 1817 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr1 | compressor temperature (TR1) | short (>=-3199<=3199) | C | false | sensor.boiler_compressor_temperature_(TR1) | sensor.boiler_hptr1 |
| 1818 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr3 | refrigerant temperature liquid side (condenser output) (TR3) | short (>=-3199<=3199) | C | false | sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) | sensor.boiler_hptr3 |
| 1819 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr4 | evaporator inlet temperature (TR4) | short (>=-3199<=3199) | C | false | sensor.boiler_evaporator_inlet_temperature_(TR4) | sensor.boiler_hptr4 |
| 1820 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr5 | compressor inlet temperature (TR5) | short (>=-3199<=3199) | C | false | sensor.boiler_compressor_inlet_temperature_(TR5) | sensor.boiler_hptr5 |
| 1821 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr6 | compressor outlet temperature (TR6) | short (>=-3199<=3199) | C | false | sensor.boiler_compressor_outlet_temperature_(TR6) | sensor.boiler_hptr6 |
| 1822 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr7 | refrigerant temperature gas side (condenser input) (TR7) | short (>=-3199<=3199) | C | false | sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7) | sensor.boiler_hptr7 |
| 1823 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptl2 | air inlet temperature (TL2) | short (>=-3199<=3199) | C | false | sensor.boiler_air_inlet_temperature_(TL2) | sensor.boiler_hptl2 |
| 1824 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hppl1 | low pressure side temperature (PL1) | short (>=-3199<=3199) | C | false | sensor.boiler_low_pressure_side_temperature_(PL1) | sensor.boiler_hppl1 |
| 1825 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpph1 | high pressure side temperature (PH1) | short (>=-3199<=3199) | C | false | sensor.boiler_high_pressure_side_temperature_(PH1) | sensor.boiler_hpph1 |
| 1826 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpta4 | drain pan temp (TA4) | short (>=-3199<=3199) | C | false | sensor.boiler_drain_pan_temp_(TA4) | sensor.boiler_hpta4 |
| 1827 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptw1 | reservoir temp (TW1) | short (>=-3199<=3199) | C | false | sensor.boiler_reservoir_temp_(TW1) | sensor.boiler_hptw1 |
| 1828 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | poolsettemp | pool set temperature | uint (>=0<=127) | C | true | number.boiler_pool_set_temperature | number.boiler_poolsettemp |
| 1829 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hp4way | 4-way valve (VR4) | enum [cooling & defrost\|heating & dhw] | false | sensor.boiler_4-way_valve_(VR4) | sensor.boiler_hp4way | |
| 1830 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpin1opt | input 1 options | string | true | sensor.boiler_input_1_options | sensor.boiler_hpin1opt | |
| 1831 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpin2opt | input 2 options | string | true | sensor.boiler_input_2_options | sensor.boiler_hpin2opt | |
| 1832 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpin3opt | input 3 options | string | true | sensor.boiler_input_3_options | sensor.boiler_hpin3opt | |
| 1833 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpin4opt | input 4 options | string | true | sensor.boiler_input_4_options | sensor.boiler_hpin4opt | |
| 1834 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maxheatcomp | heat limit compressor | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | true | select.boiler_heat_limit_compressor | select.boiler_maxheatcomp | |
| 1835 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maxheatheat | heat limit heating | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | true | select.boiler_heat_limit_heating | select.boiler_maxheatheat | |
| 1836 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maxheatdhw | heat limit | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | true | select.boiler_heat_limit | select.boiler_maxheatdhw | |
| 1837 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | mandefrost | manual defrost | boolean | true | switch.boiler_manual_defrost | switch.boiler_mandefrost | |
| 1838 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | pvcooling | Cooling only with PV | boolean | true | switch.boiler_Cooling_only_with_PV | switch.boiler_pvcooling | |
| 1839 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheateronly | aux heater only | boolean | true | switch.boiler_aux_heater_only | switch.boiler_auxheateronly | |
| 1840 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheateroff | disable aux heater | boolean | true | switch.boiler_disable_aux_heater | switch.boiler_auxheateroff | |
| 1841 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheaterstatus | aux heater status | boolean | false | binary_sensor.boiler_aux_heater_status | binary_sensor.boiler_auxheaterstatus | |
| 1842 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheaterdelay | aux heater on delay | ushort (>=10<=1000) | K*min | true | number.boiler_aux_heater_on_delay | number.boiler_auxheaterdelay |
| 1843 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxmaxlimit | aux heater max limit | uint (>=0<=10) | K | true | number.boiler_aux_heater_max_limit | number.boiler_auxmaxlimit |
| 1844 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxlimitstart | aux heater limit start | uint (>=0<=10) | K | true | number.boiler_aux_heater_limit_start | number.boiler_auxlimitstart |
| 1845 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheatrmode | aux heater mode | enum [eco\|comfort] | true | select.boiler_aux_heater_mode | select.boiler_auxheatrmode | |
| 1846 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hphystheat | on/off hyst heat | ushort (>=50<=1500) | K*min | true | number.boiler_on/off_hyst_heat | number.boiler_hphystheat |
| 1847 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hphystcool | on/off hyst cool | ushort (>=50<=1500) | K*min | true | number.boiler_on/off_hyst_cool | number.boiler_hphystcool |
| 1848 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hphystpool | on/off hyst pool | ushort (>=50<=1500) | K*min | true | number.boiler_on/off_hyst_pool | number.boiler_hphystpool |
| 1849 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | silentmode | silent mode | enum [off\|auto\|on] | true | select.boiler_silent_mode | select.boiler_silentmode | |
| 1850 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | silentfrom | silent mode from | uint (>=0<=3810) | minutes | true | number.boiler_silent_mode_from | number.boiler_silentfrom |
| 1851 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | silentto | silent mode to | uint (>=0<=3810) | minutes | true | number.boiler_silent_mode_to | number.boiler_silentto |
| 1852 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | mintempsilent | min outside temp for silent mode | int (>=-126<=126) | C | true | number.boiler_min_outside_temp_for_silent_mode | number.boiler_mintempsilent |
| 1853 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | tempparmode | outside temp parallel mode | int (>=-126<=126) | C | true | number.boiler_outside_temp_parallel_mode | number.boiler_tempparmode |
| 1854 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheatmix | aux heater mixing valve | int (>=-100<=100) | % | false | sensor.boiler_aux_heater_mixing_valve | sensor.boiler_auxheatmix |
| 1855 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | tempdiffheat | temp diff TC3/TC0 heat | uint (>=2<=10) | K | true | number.boiler_temp_diff_TC3/TC0_heat | number.boiler_tempdiffheat |
| 1856 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | tempdiffcool | temp diff TC3/TC0 cool | uint (>=2<=10) | K | true | number.boiler_temp_diff_TC3/TC0_cool | number.boiler_tempdiffcool |
| 1857 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | vpcooling | valve/pump cooling | boolean | true | switch.boiler_valve/pump_cooling | switch.boiler_vpcooling | |
| 1858 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatcable | heating cable | boolean | true | switch.boiler_heating_cable | switch.boiler_heatcable | |
| 1859 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | vc0valve | VC0 valve | boolean | true | switch.boiler_VC0_valve | switch.boiler_vc0valve | |
| 1860 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | primepump | primary heatpump | boolean | true | switch.boiler_primary_heatpump | switch.boiler_primepump | |
| 1861 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | primepumpmod | primary heatpump modulation | uint (>=0<=100) | % | true | number.boiler_primary_heatpump_modulation | number.boiler_primepumpmod |
| 1862 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hp3way | 3-way valve | boolean | true | switch.boiler_3-way_valve | switch.boiler_hp3way | |
| 1863 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | elheatstep1 | el. heater step 1 | boolean | true | switch.boiler_el._heater_step_1 | switch.boiler_elheatstep1 | |
| 1864 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | elheatstep2 | el. heater step 2 | boolean | true | switch.boiler_el._heater_step_2 | switch.boiler_elheatstep2 | |
| 1865 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | elheatstep3 | el. heater step 3 | boolean | true | switch.boiler_el._heater_step_3 | switch.boiler_elheatstep3 | |
| 1866 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpea0 | condensate reservoir heating (EA0) | boolean | false | binary_sensor.boiler_condensate_reservoir_heating_(EA0) | binary_sensor.boiler_hpea0 | |
| 1867 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwalternatingop | alternating operation | boolean | true | switch.boiler_alternating_operation | switch.boiler_wwalternatingop | |
| 1868 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwaltopprioheat | prioritise heating during dhw | uint (>=20<=120) | minutes | true | number.boiler_prioritise_heating_during_dhw | number.boiler_wwaltopprioheat |
| 1869 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwaltopprioww | prioritise dhw during heating | uint (>=30<=120) | minutes | true | number.boiler_prioritise_dhw_during_heating | number.boiler_wwaltopprioww |
| 1870 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcomfoff | comfort switch off | uint (>=15<=65) | C | true | number.boiler_comfort_switch_off | number.boiler_wwcomfoff |
| 1871 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwecooff | eco switch off | uint (>=15<=65) | C | true | number.boiler_eco_switch_off | number.boiler_wwecooff |
| 1872 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwecoplusoff | eco+ switch off | uint (>=48<=63) | C | true | number.boiler_eco+_switch_off | number.boiler_wwecoplusoff |
| 1873 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpcircpumpww | circulation pump available during dhw | boolean | true | switch.boiler_circulation_pump_available_during_dhw | switch.boiler_hpcircpumpww | |
| 1874 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 1875 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 1876 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 1877 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 1878 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwtempecoplus | selected eco+ temperature | uint (>=0<=254) | C | true | number.boiler_selected_eco+_temperature | number.boiler_wwtempecoplus |
| 1879 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 1880 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 1881 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 1882 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 1883 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 1884 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 1885 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 1886 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 1887 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 1888 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwmaxtemp | maximum temperature | uint (>=0<=80) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 1889 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 1890 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 1891 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 1892 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 1893 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwdisinfectiontemp | disinfection temperature | uint (>=60<=80) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 1894 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 1895 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 1896 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 1897 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 1898 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 1899 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 1900 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 1901 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 1902 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 1903 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 1904 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 1905 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 1906 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 1907 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 1908 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 1909 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 1910 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 1911 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 1912 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwstarts | starts | ulong (>=0<=16777213) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 1913 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwworkm | active time | time (>=0<=16777213) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 1914 | Geo 5xx | boiler | 173 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 1915 | Geo 5xx | boiler | 173 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 1916 | Geo 5xx | boiler | 173 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 1917 | Geo 5xx | boiler | 173 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 1918 | Geo 5xx | boiler | 173 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 1919 | Geo 5xx | boiler | 173 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 1920 | Geo 5xx | boiler | 173 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 1921 | Geo 5xx | boiler | 173 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 1922 | Geo 5xx | boiler | 173 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 1923 | Geo 5xx | boiler | 173 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 1924 | Geo 5xx | boiler | 173 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 1925 | Geo 5xx | boiler | 173 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 1926 | Geo 5xx | boiler | 173 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 1927 | Geo 5xx | boiler | 173 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 1928 | Geo 5xx | boiler | 173 | heatingtemp | heating temperature | uint (>=0<=90) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 1929 | Geo 5xx | boiler | 173 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 1930 | Geo 5xx | boiler | 173 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 1931 | Geo 5xx | boiler | 173 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 1932 | Geo 5xx | boiler | 173 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 1933 | Geo 5xx | boiler | 173 | pumpdelay | pump delay | uint (>=0<=60) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 1934 | Geo 5xx | boiler | 173 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 1935 | Geo 5xx | boiler | 173 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 1936 | Geo 5xx | boiler | 173 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 1937 | Geo 5xx | boiler | 173 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 1938 | Geo 5xx | boiler | 173 | burnstarts | burner starts | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 1939 | Geo 5xx | boiler | 173 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 1940 | Geo 5xx | boiler | 173 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 1941 | Geo 5xx | boiler | 173 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 1942 | Geo 5xx | boiler | 173 | heatstarts | burner starts heating | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 1943 | Geo 5xx | boiler | 173 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 1944 | Geo 5xx | boiler | 173 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 1945 | Geo 5xx | boiler | 173 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 1946 | Geo 5xx | boiler | 173 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 1947 | Geo 5xx | boiler | 173 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 1948 | Geo 5xx | boiler | 173 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 1949 | Geo 5xx | boiler | 173 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 1950 | Geo 5xx | boiler | 173 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 1951 | Geo 5xx | boiler | 173 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 1952 | Geo 5xx | boiler | 173 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 1953 | Geo 5xx | boiler | 173 | nrgtotal | total energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
| 1954 | Geo 5xx | boiler | 173 | nrgww | energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_energy | sensor.boiler_nrgww |
| 1955 | Geo 5xx | boiler | 173 | nrgheat | energy heating | ulong (>=0<=167772) | kWh | false | sensor.boiler_energy_heating | sensor.boiler_nrgheat |
| 1956 | Geo 5xx | boiler | 173 | metertotal | meter total | ulong (>=0<=167772) | kWh | false | sensor.boiler_meter_total | sensor.boiler_metertotal |
| 1957 | Geo 5xx | boiler | 173 | metercomp | meter compressor | ulong (>=0<=167772) | kWh | false | sensor.boiler_meter_compressor | sensor.boiler_metercomp |
| 1958 | Geo 5xx | boiler | 173 | metereheat | meter e-heater | ulong (>=0<=167772) | kWh | false | sensor.boiler_meter_e-heater | sensor.boiler_metereheat |
| 1959 | Geo 5xx | boiler | 173 | uptimetotal | heatpump total uptime | time (>=0<=279620) | minutes | false | sensor.boiler_heatpump_total_uptime | sensor.boiler_uptimetotal |
| 1960 | Geo 5xx | boiler | 173 | uptimecontrol | total operating time heat | time (>=0<=279620) | minutes | false | sensor.boiler_total_operating_time_heat | sensor.boiler_uptimecontrol |
| 1961 | Geo 5xx | boiler | 173 | uptimecompheating | operating time compressor heating | time (>=0<=279620) | minutes | false | sensor.boiler_operating_time_compressor_heating | sensor.boiler_uptimecompheating |
| 1962 | Geo 5xx | boiler | 173 | uptimecompcooling | operating time compressor cooling | time (>=0<=279620) | minutes | false | sensor.boiler_operating_time_compressor_cooling | sensor.boiler_uptimecompcooling |
| 1963 | Geo 5xx | boiler | 173 | uptimecompww | operating time compressor | time (>=0<=279620) | minutes | false | sensor.boiler_operating_time_compressor | sensor.boiler_uptimecompww |
| 1964 | Geo 5xx | boiler | 173 | uptimecomppool | operating time compressor pool | time (>=0<=279620) | minutes | false | sensor.boiler_operating_time_compressor_pool | sensor.boiler_uptimecomppool |
| 1965 | Geo 5xx | boiler | 173 | totalcompstarts | total compressor control starts | ulong (>=0<=16777213) | false | sensor.boiler_total_compressor_control_starts | sensor.boiler_totalcompstarts | |
| 1966 | Geo 5xx | boiler | 173 | heatingstarts | heating control starts | ulong (>=0<=16777213) | false | sensor.boiler_heating_control_starts | sensor.boiler_heatingstarts | |
| 1967 | Geo 5xx | boiler | 173 | coolingstarts | cooling control starts | ulong (>=0<=16777213) | false | sensor.boiler_cooling_control_starts | sensor.boiler_coolingstarts | |
| 1968 | Geo 5xx | boiler | 173 | wwstarts2 | control starts2 | ulong (>=0<=16777213) | false | sensor.boiler_control_starts2 | sensor.boiler_wwstarts2 | |
| 1969 | Geo 5xx | boiler | 173 | poolstarts | pool control starts | ulong (>=0<=16777213) | false | sensor.boiler_pool_control_starts | sensor.boiler_poolstarts | |
| 1970 | Geo 5xx | boiler | 173 | nrgconstotal | total energy consumption | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_energy_consumption | sensor.boiler_nrgconstotal |
| 1971 | Geo 5xx | boiler | 173 | nrgconscomptotal | total energy consumption compressor | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_energy_consumption_compressor | sensor.boiler_nrgconscomptotal |
| 1972 | Geo 5xx | boiler | 173 | nrgconscompheating | energy consumption compressor heating | ulong (>=0<=16777213) | kWh | false | sensor.boiler_energy_consumption_compressor_heating | sensor.boiler_nrgconscompheating |
| 1973 | Geo 5xx | boiler | 173 | nrgconscompww | energy consumption compressor | ulong (>=0<=16777213) | kWh | false | sensor.boiler_energy_consumption_compressor | sensor.boiler_nrgconscompww |
| 1974 | Geo 5xx | boiler | 173 | nrgconscompcooling | energy consumption compressor cooling | ulong (>=0<=16777213) | kWh | false | sensor.boiler_energy_consumption_compressor_cooling | sensor.boiler_nrgconscompcooling |
| 1975 | Geo 5xx | boiler | 173 | nrgconscomppool | energy consumption compressor pool | ulong (>=0<=16777213) | kWh | false | sensor.boiler_energy_consumption_compressor_pool | sensor.boiler_nrgconscomppool |
| 1976 | Geo 5xx | boiler | 173 | auxelecheatnrgconstotal | total aux elec. heater energy consumption | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_aux_elec._heater_energy_consumption | sensor.boiler_auxelecheatnrgconstotal |
| 1977 | Geo 5xx | boiler | 173 | auxelecheatnrgconsheating | aux elec. heater energy consumption heating | ulong (>=0<=16777213) | kWh | false | sensor.boiler_aux_elec._heater_energy_consumption_heating | sensor.boiler_auxelecheatnrgconsheating |
| 1978 | Geo 5xx | boiler | 173 | auxelecheatnrgconsww | aux elec. heater energy consumption | ulong (>=0<=16777213) | kWh | false | sensor.boiler_aux_elec._heater_energy_consumption | sensor.boiler_auxelecheatnrgconsww |
| 1979 | Geo 5xx | boiler | 173 | auxelecheatnrgconspool | aux elec. heater energy consumption pool | ulong (>=0<=16777213) | kWh | false | sensor.boiler_aux_elec._heater_energy_consumption_pool | sensor.boiler_auxelecheatnrgconspool |
| 1980 | Geo 5xx | boiler | 173 | nrgsupptotal | total energy supplied | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_energy_supplied | sensor.boiler_nrgsupptotal |
| 1981 | Geo 5xx | boiler | 173 | nrgsuppheating | total energy supplied heating | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_energy_supplied_heating | sensor.boiler_nrgsuppheating |
| 1982 | Geo 5xx | boiler | 173 | nrgsuppww | total energy warm supplied | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_energy_warm_supplied | sensor.boiler_nrgsuppww |
| 1983 | Geo 5xx | boiler | 173 | nrgsuppcooling | total energy supplied cooling | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_energy_supplied_cooling | sensor.boiler_nrgsuppcooling |
| 1984 | Geo 5xx | boiler | 173 | nrgsupppool | total energy supplied pool | ulong (>=0<=16777213) | kWh | false | sensor.boiler_total_energy_supplied_pool | sensor.boiler_nrgsupppool |
| 1985 | Geo 5xx | boiler | 173 | hppower | compressor power output | uint (>=0<=25) | kW | false | sensor.boiler_compressor_power_output | sensor.boiler_hppower |
| 1986 | Geo 5xx | boiler | 173 | hpcompon | hp compressor | boolean | false | binary_sensor.boiler_hp_compressor | binary_sensor.boiler_hpcompon | |
| 1987 | Geo 5xx | boiler | 173 | hpactivity | compressor activity | enum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost] | false | sensor.boiler_compressor_activity | sensor.boiler_hpactivity | |
| 1988 | Geo 5xx | boiler | 173 | hpbrinepumpspd | brine pump speed | uint (>=0<=100) | % | false | sensor.boiler_brine_pump_speed | sensor.boiler_hpbrinepumpspd |
| 1989 | Geo 5xx | boiler | 173 | hpswitchvalve | switch valve | boolean | false | binary_sensor.boiler_switch_valve | binary_sensor.boiler_hpswitchvalve | |
| 1990 | Geo 5xx | boiler | 173 | hpcompspd | compressor speed | uint (>=0<=100) | % | false | sensor.boiler_compressor_speed | sensor.boiler_hpcompspd |
| 1991 | Geo 5xx | boiler | 173 | hpcircspd | circulation pump speed | uint (>=0<=100) | % | false | sensor.boiler_circulation_pump_speed | sensor.boiler_hpcircspd |
| 1992 | Geo 5xx | boiler | 173 | hpbrinein | brine in/evaporator | short (>=-3199<=3199) | C | false | sensor.boiler_brine_in/evaporator | sensor.boiler_hpbrinein |
| 1993 | Geo 5xx | boiler | 173 | hpbrineout | brine out/condenser | short (>=-3199<=3199) | C | false | sensor.boiler_brine_out/condenser | sensor.boiler_hpbrineout |
| 1994 | Geo 5xx | boiler | 173 | hptc0 | heat carrier return (TC0) | short (>=-3199<=3199) | C | false | sensor.boiler_heat_carrier_return_(TC0) | sensor.boiler_hptc0 |
| 1995 | Geo 5xx | boiler | 173 | hptc1 | heat carrier forward (TC1) | short (>=-3199<=3199) | C | false | sensor.boiler_heat_carrier_forward_(TC1) | sensor.boiler_hptc1 |
| 1996 | Geo 5xx | boiler | 173 | hptc3 | condenser temperature (TC3) | short (>=-3199<=3199) | C | false | sensor.boiler_condenser_temperature_(TC3) | sensor.boiler_hptc3 |
| 1997 | Geo 5xx | boiler | 173 | hptr1 | compressor temperature (TR1) | short (>=-3199<=3199) | C | false | sensor.boiler_compressor_temperature_(TR1) | sensor.boiler_hptr1 |
| 1998 | Geo 5xx | boiler | 173 | hptr3 | refrigerant temperature liquid side (condenser output) (TR3) | short (>=-3199<=3199) | C | false | sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) | sensor.boiler_hptr3 |
| 1999 | Geo 5xx | boiler | 173 | hptr4 | evaporator inlet temperature (TR4) | short (>=-3199<=3199) | C | false | sensor.boiler_evaporator_inlet_temperature_(TR4) | sensor.boiler_hptr4 |
| 2000 | Geo 5xx | boiler | 173 | hptr5 | compressor inlet temperature (TR5) | short (>=-3199<=3199) | C | false | sensor.boiler_compressor_inlet_temperature_(TR5) | sensor.boiler_hptr5 |
| 2001 | Geo 5xx | boiler | 173 | hptr6 | compressor outlet temperature (TR6) | short (>=-3199<=3199) | C | false | sensor.boiler_compressor_outlet_temperature_(TR6) | sensor.boiler_hptr6 |
| 2002 | Geo 5xx | boiler | 173 | hptr7 | refrigerant temperature gas side (condenser input) (TR7) | short (>=-3199<=3199) | C | false | sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7) | sensor.boiler_hptr7 |
| 2003 | Geo 5xx | boiler | 173 | hptl2 | air inlet temperature (TL2) | short (>=-3199<=3199) | C | false | sensor.boiler_air_inlet_temperature_(TL2) | sensor.boiler_hptl2 |
| 2004 | Geo 5xx | boiler | 173 | hppl1 | low pressure side temperature (PL1) | short (>=-3199<=3199) | C | false | sensor.boiler_low_pressure_side_temperature_(PL1) | sensor.boiler_hppl1 |
| 2005 | Geo 5xx | boiler | 173 | hpph1 | high pressure side temperature (PH1) | short (>=-3199<=3199) | C | false | sensor.boiler_high_pressure_side_temperature_(PH1) | sensor.boiler_hpph1 |
| 2006 | Geo 5xx | boiler | 173 | hpta4 | drain pan temp (TA4) | short (>=-3199<=3199) | C | false | sensor.boiler_drain_pan_temp_(TA4) | sensor.boiler_hpta4 |
| 2007 | Geo 5xx | boiler | 173 | hptw1 | reservoir temp (TW1) | short (>=-3199<=3199) | C | false | sensor.boiler_reservoir_temp_(TW1) | sensor.boiler_hptw1 |
| 2008 | Geo 5xx | boiler | 173 | poolsettemp | pool set temperature | uint (>=0<=127) | C | true | number.boiler_pool_set_temperature | number.boiler_poolsettemp |
| 2009 | Geo 5xx | boiler | 173 | hp4way | 4-way valve (VR4) | enum [cooling & defrost\|heating & dhw] | false | sensor.boiler_4-way_valve_(VR4) | sensor.boiler_hp4way | |
| 2010 | Geo 5xx | boiler | 173 | hpin1opt | input 1 options | string | true | sensor.boiler_input_1_options | sensor.boiler_hpin1opt | |
| 2011 | Geo 5xx | boiler | 173 | hpin2opt | input 2 options | string | true | sensor.boiler_input_2_options | sensor.boiler_hpin2opt | |
| 2012 | Geo 5xx | boiler | 173 | hpin3opt | input 3 options | string | true | sensor.boiler_input_3_options | sensor.boiler_hpin3opt | |
| 2013 | Geo 5xx | boiler | 173 | hpin4opt | input 4 options | string | true | sensor.boiler_input_4_options | sensor.boiler_hpin4opt | |
| 2014 | Geo 5xx | boiler | 173 | maxheatcomp | heat limit compressor | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | true | select.boiler_heat_limit_compressor | select.boiler_maxheatcomp | |
| 2015 | Geo 5xx | boiler | 173 | maxheatheat | heat limit heating | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | true | select.boiler_heat_limit_heating | select.boiler_maxheatheat | |
| 2016 | Geo 5xx | boiler | 173 | maxheatdhw | heat limit | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | true | select.boiler_heat_limit | select.boiler_maxheatdhw | |
| 2017 | Geo 5xx | boiler | 173 | mandefrost | manual defrost | boolean | true | switch.boiler_manual_defrost | switch.boiler_mandefrost | |
| 2018 | Geo 5xx | boiler | 173 | pvcooling | Cooling only with PV | boolean | true | switch.boiler_Cooling_only_with_PV | switch.boiler_pvcooling | |
| 2019 | Geo 5xx | boiler | 173 | auxheateronly | aux heater only | boolean | true | switch.boiler_aux_heater_only | switch.boiler_auxheateronly | |
| 2020 | Geo 5xx | boiler | 173 | auxheateroff | disable aux heater | boolean | true | switch.boiler_disable_aux_heater | switch.boiler_auxheateroff | |
| 2021 | Geo 5xx | boiler | 173 | auxheaterstatus | aux heater status | boolean | false | binary_sensor.boiler_aux_heater_status | binary_sensor.boiler_auxheaterstatus | |
| 2022 | Geo 5xx | boiler | 173 | auxheaterdelay | aux heater on delay | ushort (>=10<=1000) | K*min | true | number.boiler_aux_heater_on_delay | number.boiler_auxheaterdelay |
| 2023 | Geo 5xx | boiler | 173 | auxmaxlimit | aux heater max limit | uint (>=0<=10) | K | true | number.boiler_aux_heater_max_limit | number.boiler_auxmaxlimit |
| 2024 | Geo 5xx | boiler | 173 | auxlimitstart | aux heater limit start | uint (>=0<=10) | K | true | number.boiler_aux_heater_limit_start | number.boiler_auxlimitstart |
| 2025 | Geo 5xx | boiler | 173 | auxheatrmode | aux heater mode | enum [eco\|comfort] | true | select.boiler_aux_heater_mode | select.boiler_auxheatrmode | |
| 2026 | Geo 5xx | boiler | 173 | hphystheat | on/off hyst heat | ushort (>=50<=1500) | K*min | true | number.boiler_on/off_hyst_heat | number.boiler_hphystheat |
| 2027 | Geo 5xx | boiler | 173 | hphystcool | on/off hyst cool | ushort (>=50<=1500) | K*min | true | number.boiler_on/off_hyst_cool | number.boiler_hphystcool |
| 2028 | Geo 5xx | boiler | 173 | hphystpool | on/off hyst pool | ushort (>=50<=1500) | K*min | true | number.boiler_on/off_hyst_pool | number.boiler_hphystpool |
| 2029 | Geo 5xx | boiler | 173 | silentmode | silent mode | enum [off\|auto\|on] | true | select.boiler_silent_mode | select.boiler_silentmode | |
| 2030 | Geo 5xx | boiler | 173 | silentfrom | silent mode from | uint (>=0<=3810) | minutes | true | number.boiler_silent_mode_from | number.boiler_silentfrom |
| 2031 | Geo 5xx | boiler | 173 | silentto | silent mode to | uint (>=0<=3810) | minutes | true | number.boiler_silent_mode_to | number.boiler_silentto |
| 2032 | Geo 5xx | boiler | 173 | mintempsilent | min outside temp for silent mode | int (>=-126<=126) | C | true | number.boiler_min_outside_temp_for_silent_mode | number.boiler_mintempsilent |
| 2033 | Geo 5xx | boiler | 173 | tempparmode | outside temp parallel mode | int (>=-126<=126) | C | true | number.boiler_outside_temp_parallel_mode | number.boiler_tempparmode |
| 2034 | Geo 5xx | boiler | 173 | auxheatmix | aux heater mixing valve | int (>=-100<=100) | % | false | sensor.boiler_aux_heater_mixing_valve | sensor.boiler_auxheatmix |
| 2035 | Geo 5xx | boiler | 173 | tempdiffheat | temp diff TC3/TC0 heat | uint (>=2<=10) | K | true | number.boiler_temp_diff_TC3/TC0_heat | number.boiler_tempdiffheat |
| 2036 | Geo 5xx | boiler | 173 | tempdiffcool | temp diff TC3/TC0 cool | uint (>=2<=10) | K | true | number.boiler_temp_diff_TC3/TC0_cool | number.boiler_tempdiffcool |
| 2037 | Geo 5xx | boiler | 173 | vpcooling | valve/pump cooling | boolean | true | switch.boiler_valve/pump_cooling | switch.boiler_vpcooling | |
| 2038 | Geo 5xx | boiler | 173 | heatcable | heating cable | boolean | true | switch.boiler_heating_cable | switch.boiler_heatcable | |
| 2039 | Geo 5xx | boiler | 173 | vc0valve | VC0 valve | boolean | true | switch.boiler_VC0_valve | switch.boiler_vc0valve | |
| 2040 | Geo 5xx | boiler | 173 | primepump | primary heatpump | boolean | true | switch.boiler_primary_heatpump | switch.boiler_primepump | |
| 2041 | Geo 5xx | boiler | 173 | primepumpmod | primary heatpump modulation | uint (>=0<=100) | % | true | number.boiler_primary_heatpump_modulation | number.boiler_primepumpmod |
| 2042 | Geo 5xx | boiler | 173 | hp3way | 3-way valve | boolean | true | switch.boiler_3-way_valve | switch.boiler_hp3way | |
| 2043 | Geo 5xx | boiler | 173 | elheatstep1 | el. heater step 1 | boolean | true | switch.boiler_el._heater_step_1 | switch.boiler_elheatstep1 | |
| 2044 | Geo 5xx | boiler | 173 | elheatstep2 | el. heater step 2 | boolean | true | switch.boiler_el._heater_step_2 | switch.boiler_elheatstep2 | |
| 2045 | Geo 5xx | boiler | 173 | elheatstep3 | el. heater step 3 | boolean | true | switch.boiler_el._heater_step_3 | switch.boiler_elheatstep3 | |
| 2046 | Geo 5xx | boiler | 173 | hpea0 | condensate reservoir heating (EA0) | boolean | false | binary_sensor.boiler_condensate_reservoir_heating_(EA0) | binary_sensor.boiler_hpea0 | |
| 2047 | Geo 5xx | boiler | 173 | wwalternatingop | alternating operation | boolean | true | switch.boiler_alternating_operation | switch.boiler_wwalternatingop | |
| 2048 | Geo 5xx | boiler | 173 | wwaltopprioheat | prioritise heating during dhw | uint (>=20<=120) | minutes | true | number.boiler_prioritise_heating_during_dhw | number.boiler_wwaltopprioheat |
| 2049 | Geo 5xx | boiler | 173 | wwaltopprioww | prioritise dhw during heating | uint (>=30<=120) | minutes | true | number.boiler_prioritise_dhw_during_heating | number.boiler_wwaltopprioww |
| 2050 | Geo 5xx | boiler | 173 | wwcomfoff | comfort switch off | uint (>=15<=65) | C | true | number.boiler_comfort_switch_off | number.boiler_wwcomfoff |
| 2051 | Geo 5xx | boiler | 173 | wwecooff | eco switch off | uint (>=15<=65) | C | true | number.boiler_eco_switch_off | number.boiler_wwecooff |
| 2052 | Geo 5xx | boiler | 173 | wwecoplusoff | eco+ switch off | uint (>=48<=63) | C | true | number.boiler_eco+_switch_off | number.boiler_wwecoplusoff |
| 2053 | Geo 5xx | boiler | 173 | hpcircpumpww | circulation pump available during dhw | boolean | true | switch.boiler_circulation_pump_available_during_dhw | switch.boiler_hpcircpumpww | |
| 2054 | Geo 5xx | boiler | 173 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 2055 | Geo 5xx | boiler | 173 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 2056 | Geo 5xx | boiler | 173 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 2057 | Geo 5xx | boiler | 173 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 2058 | Geo 5xx | boiler | 173 | wwtempecoplus | selected eco+ temperature | uint (>=0<=254) | C | true | number.boiler_selected_eco+_temperature | number.boiler_wwtempecoplus |
| 2059 | Geo 5xx | boiler | 173 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 2060 | Geo 5xx | boiler | 173 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 2061 | Geo 5xx | boiler | 173 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 2062 | Geo 5xx | boiler | 173 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 2063 | Geo 5xx | boiler | 173 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 2064 | Geo 5xx | boiler | 173 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 2065 | Geo 5xx | boiler | 173 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 2066 | Geo 5xx | boiler | 173 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 2067 | Geo 5xx | boiler | 173 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 2068 | Geo 5xx | boiler | 173 | wwmaxtemp | maximum temperature | uint (>=0<=80) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 2069 | Geo 5xx | boiler | 173 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 2070 | Geo 5xx | boiler | 173 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 2071 | Geo 5xx | boiler | 173 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 2072 | Geo 5xx | boiler | 173 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 2073 | Geo 5xx | boiler | 173 | wwdisinfectiontemp | disinfection temperature | uint (>=60<=80) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 2074 | Geo 5xx | boiler | 173 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 2075 | Geo 5xx | boiler | 173 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 2076 | Geo 5xx | boiler | 173 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 2077 | Geo 5xx | boiler | 173 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 2078 | Geo 5xx | boiler | 173 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 2079 | Geo 5xx | boiler | 173 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 2080 | Geo 5xx | boiler | 173 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 2081 | Geo 5xx | boiler | 173 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 2082 | Geo 5xx | boiler | 173 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 2083 | Geo 5xx | boiler | 173 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 2084 | Geo 5xx | boiler | 173 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 2085 | Geo 5xx | boiler | 173 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 2086 | Geo 5xx | boiler | 173 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 2087 | Geo 5xx | boiler | 173 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 2088 | Geo 5xx | boiler | 173 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 2089 | Geo 5xx | boiler | 173 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 2090 | Geo 5xx | boiler | 173 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 2091 | Geo 5xx | boiler | 173 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 2092 | Geo 5xx | boiler | 173 | wwstarts | starts | ulong (>=0<=16777213) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 2093 | Geo 5xx | boiler | 173 | wwworkm | active time | time (>=0<=16777213) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 2094 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 2095 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 2096 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 2097 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 2098 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 2099 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 2100 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 2101 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 2102 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 2103 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 2104 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 2105 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 2106 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 2107 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 2108 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 2109 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 2110 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 2111 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 2112 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 2113 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 2114 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 2115 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 2116 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | burnminperiod | burner min period | uint (>=0<=120) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 2117 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 2118 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | heatblock | heating block | ushort (>=0<=3199) | C | false | sensor.boiler_heating_block | sensor.boiler_heatblock |
| 2119 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | boilhyston | hysteresis on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 2120 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | boilhystoff | hysteresis off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 2121 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 2122 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | heatingtemp | heating temperature | uint (>=0<=90) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 2123 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 2124 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 2125 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 2126 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 2127 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | pumpdelay | pump delay | uint (>=0<=60) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 2128 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 2129 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 2130 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 2131 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 2132 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | burnstarts | burner starts | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 2133 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 2134 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 2135 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 2136 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | heatstarts | burner starts heating | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 2137 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 2138 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 2139 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 2140 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 2141 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 2142 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 2143 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 2144 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 2145 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 2146 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 2147 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 2148 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 2149 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 2150 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 2151 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwtempecoplus | selected eco+ temperature | uint (>=0<=254) | C | true | number.boiler_selected_eco+_temperature | number.boiler_wwtempecoplus |
| 2152 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 2153 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 2154 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 2155 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 2156 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 2157 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 2158 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 2159 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 2160 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 2161 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwmaxtemp | maximum temperature | uint (>=0<=80) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 2162 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 2163 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 2164 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 2165 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 2166 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwdisinfectiontemp | disinfection temperature | uint (>=60<=80) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 2167 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 2168 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 2169 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 2170 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 2171 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 2172 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 2173 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 2174 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 2175 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 2176 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 2177 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 2178 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 2179 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 2180 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 2181 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 2182 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 2183 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 2184 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 2185 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwstarts | starts | ulong (>=0<=16777213) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 2186 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | wwworkm | active time | time (>=0<=16777213) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 2187 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | nompower | nominal Power | uint (>=0<=254) | kW | true | number.boiler_nominal_Power | number.boiler_nompower |
| 2188 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | nrgtotal | total energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
| 2189 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | nrgheat | energy heating | ulong (>=0<=10000000) | kWh | true | number.boiler_energy_heating | number.boiler_nrgheat |
| 2190 | Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2 | boiler | 195 | nrgww | energy | ulong (>=0<=10000000) | kWh | true | number.boiler_energy | number.boiler_nrgww |
| 2191 | Logamax U122/Cerapur | boiler | 203 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 2192 | Logamax U122/Cerapur | boiler | 203 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 2193 | Logamax U122/Cerapur | boiler | 203 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 2194 | Logamax U122/Cerapur | boiler | 203 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 2195 | Logamax U122/Cerapur | boiler | 203 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 2196 | Logamax U122/Cerapur | boiler | 203 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 2197 | Logamax U122/Cerapur | boiler | 203 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 2198 | Logamax U122/Cerapur | boiler | 203 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 2199 | Logamax U122/Cerapur | boiler | 203 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 2200 | Logamax U122/Cerapur | boiler | 203 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 2201 | Logamax U122/Cerapur | boiler | 203 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 2202 | Logamax U122/Cerapur | boiler | 203 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 2203 | Logamax U122/Cerapur | boiler | 203 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 2204 | Logamax U122/Cerapur | boiler | 203 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 2205 | Logamax U122/Cerapur | boiler | 203 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 2206 | Logamax U122/Cerapur | boiler | 203 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 2207 | Logamax U122/Cerapur | boiler | 203 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 2208 | Logamax U122/Cerapur | boiler | 203 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 2209 | Logamax U122/Cerapur | boiler | 203 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 2210 | Logamax U122/Cerapur | boiler | 203 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 2211 | Logamax U122/Cerapur | boiler | 203 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 2212 | Logamax U122/Cerapur | boiler | 203 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 2213 | Logamax U122/Cerapur | boiler | 203 | burnminperiod | burner min period | uint (>=0<=120) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 2214 | Logamax U122/Cerapur | boiler | 203 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 2215 | Logamax U122/Cerapur | boiler | 203 | heatblock | heating block | ushort (>=0<=3199) | C | false | sensor.boiler_heating_block | sensor.boiler_heatblock |
| 2216 | Logamax U122/Cerapur | boiler | 203 | boilhyston | hysteresis on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 2217 | Logamax U122/Cerapur | boiler | 203 | boilhystoff | hysteresis off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 2218 | Logamax U122/Cerapur | boiler | 203 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 2219 | Logamax U122/Cerapur | boiler | 203 | heatingtemp | heating temperature | uint (>=0<=90) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 2220 | Logamax U122/Cerapur | boiler | 203 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 2221 | Logamax U122/Cerapur | boiler | 203 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 2222 | Logamax U122/Cerapur | boiler | 203 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 2223 | Logamax U122/Cerapur | boiler | 203 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 2224 | Logamax U122/Cerapur | boiler | 203 | pumpdelay | pump delay | uint (>=0<=60) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 2225 | Logamax U122/Cerapur | boiler | 203 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 2226 | Logamax U122/Cerapur | boiler | 203 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 2227 | Logamax U122/Cerapur | boiler | 203 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 2228 | Logamax U122/Cerapur | boiler | 203 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 2229 | Logamax U122/Cerapur | boiler | 203 | burnstarts | burner starts | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 2230 | Logamax U122/Cerapur | boiler | 203 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 2231 | Logamax U122/Cerapur | boiler | 203 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 2232 | Logamax U122/Cerapur | boiler | 203 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 2233 | Logamax U122/Cerapur | boiler | 203 | heatstarts | burner starts heating | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 2234 | Logamax U122/Cerapur | boiler | 203 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 2235 | Logamax U122/Cerapur | boiler | 203 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 2236 | Logamax U122/Cerapur | boiler | 203 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 2237 | Logamax U122/Cerapur | boiler | 203 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 2238 | Logamax U122/Cerapur | boiler | 203 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 2239 | Logamax U122/Cerapur | boiler | 203 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 2240 | Logamax U122/Cerapur | boiler | 203 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 2241 | Logamax U122/Cerapur | boiler | 203 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 2242 | Logamax U122/Cerapur | boiler | 203 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 2243 | Logamax U122/Cerapur | boiler | 203 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 2244 | Logamax U122/Cerapur | boiler | 203 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 2245 | Logamax U122/Cerapur | boiler | 203 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 2246 | Logamax U122/Cerapur | boiler | 203 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 2247 | Logamax U122/Cerapur | boiler | 203 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 2248 | Logamax U122/Cerapur | boiler | 203 | wwtempecoplus | selected eco+ temperature | uint (>=0<=254) | C | true | number.boiler_selected_eco+_temperature | number.boiler_wwtempecoplus |
| 2249 | Logamax U122/Cerapur | boiler | 203 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 2250 | Logamax U122/Cerapur | boiler | 203 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 2251 | Logamax U122/Cerapur | boiler | 203 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 2252 | Logamax U122/Cerapur | boiler | 203 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 2253 | Logamax U122/Cerapur | boiler | 203 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 2254 | Logamax U122/Cerapur | boiler | 203 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 2255 | Logamax U122/Cerapur | boiler | 203 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 2256 | Logamax U122/Cerapur | boiler | 203 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 2257 | Logamax U122/Cerapur | boiler | 203 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 2258 | Logamax U122/Cerapur | boiler | 203 | wwmaxtemp | maximum temperature | uint (>=0<=80) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 2259 | Logamax U122/Cerapur | boiler | 203 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 2260 | Logamax U122/Cerapur | boiler | 203 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 2261 | Logamax U122/Cerapur | boiler | 203 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 2262 | Logamax U122/Cerapur | boiler | 203 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 2263 | Logamax U122/Cerapur | boiler | 203 | wwdisinfectiontemp | disinfection temperature | uint (>=60<=80) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 2264 | Logamax U122/Cerapur | boiler | 203 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 2265 | Logamax U122/Cerapur | boiler | 203 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 2266 | Logamax U122/Cerapur | boiler | 203 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 2267 | Logamax U122/Cerapur | boiler | 203 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 2268 | Logamax U122/Cerapur | boiler | 203 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 2269 | Logamax U122/Cerapur | boiler | 203 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 2270 | Logamax U122/Cerapur | boiler | 203 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 2271 | Logamax U122/Cerapur | boiler | 203 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 2272 | Logamax U122/Cerapur | boiler | 203 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 2273 | Logamax U122/Cerapur | boiler | 203 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 2274 | Logamax U122/Cerapur | boiler | 203 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 2275 | Logamax U122/Cerapur | boiler | 203 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 2276 | Logamax U122/Cerapur | boiler | 203 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 2277 | Logamax U122/Cerapur | boiler | 203 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 2278 | Logamax U122/Cerapur | boiler | 203 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 2279 | Logamax U122/Cerapur | boiler | 203 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 2280 | Logamax U122/Cerapur | boiler | 203 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 2281 | Logamax U122/Cerapur | boiler | 203 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 2282 | Logamax U122/Cerapur | boiler | 203 | wwstarts | starts | ulong (>=0<=16777213) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 2283 | Logamax U122/Cerapur | boiler | 203 | wwworkm | active time | time (>=0<=16777213) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 2284 | Logamax U122/Cerapur | boiler | 203 | nompower | nominal Power | uint (>=0<=254) | kW | true | number.boiler_nominal_Power | number.boiler_nompower |
| 2285 | Logamax U122/Cerapur | boiler | 203 | nrgtotal | total energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
| 2286 | Logamax U122/Cerapur | boiler | 203 | nrgheat | energy heating | ulong (>=0<=10000000) | kWh | true | number.boiler_energy_heating | number.boiler_nrgheat |
| 2287 | Logamax U122/Cerapur | boiler | 203 | nrgww | energy | ulong (>=0<=10000000) | kWh | true | number.boiler_energy | number.boiler_nrgww |
| 2288 | Ecomline Excellent | boiler | 206 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 2289 | Ecomline Excellent | boiler | 206 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 2290 | Ecomline Excellent | boiler | 206 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 2291 | Ecomline Excellent | boiler | 206 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 2292 | Ecomline Excellent | boiler | 206 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 2293 | Ecomline Excellent | boiler | 206 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 2294 | Ecomline Excellent | boiler | 206 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 2295 | Ecomline Excellent | boiler | 206 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 2296 | Ecomline Excellent | boiler | 206 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 2297 | Ecomline Excellent | boiler | 206 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 2298 | Ecomline Excellent | boiler | 206 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 2299 | Ecomline Excellent | boiler | 206 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 2300 | Ecomline Excellent | boiler | 206 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 2301 | Ecomline Excellent | boiler | 206 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 2302 | Ecomline Excellent | boiler | 206 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 2303 | Ecomline Excellent | boiler | 206 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 2304 | Ecomline Excellent | boiler | 206 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 2305 | Ecomline Excellent | boiler | 206 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 2306 | Ecomline Excellent | boiler | 206 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 2307 | Ecomline Excellent | boiler | 206 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 2308 | Ecomline Excellent | boiler | 206 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 2309 | Ecomline Excellent | boiler | 206 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 2310 | Ecomline Excellent | boiler | 206 | burnminperiod | burner min period | uint (>=0<=120) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 2311 | Ecomline Excellent | boiler | 206 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 2312 | Ecomline Excellent | boiler | 206 | heatblock | heating block | ushort (>=0<=3199) | C | false | sensor.boiler_heating_block | sensor.boiler_heatblock |
| 2313 | Ecomline Excellent | boiler | 206 | boilhyston | hysteresis on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 2314 | Ecomline Excellent | boiler | 206 | boilhystoff | hysteresis off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 2315 | Ecomline Excellent | boiler | 206 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 2316 | Ecomline Excellent | boiler | 206 | heatingtemp | heating temperature | uint (>=0<=90) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 2317 | Ecomline Excellent | boiler | 206 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 2318 | Ecomline Excellent | boiler | 206 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 2319 | Ecomline Excellent | boiler | 206 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 2320 | Ecomline Excellent | boiler | 206 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 2321 | Ecomline Excellent | boiler | 206 | pumpdelay | pump delay | uint (>=0<=60) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 2322 | Ecomline Excellent | boiler | 206 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 2323 | Ecomline Excellent | boiler | 206 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 2324 | Ecomline Excellent | boiler | 206 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 2325 | Ecomline Excellent | boiler | 206 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 2326 | Ecomline Excellent | boiler | 206 | burnstarts | burner starts | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 2327 | Ecomline Excellent | boiler | 206 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 2328 | Ecomline Excellent | boiler | 206 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 2329 | Ecomline Excellent | boiler | 206 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 2330 | Ecomline Excellent | boiler | 206 | heatstarts | burner starts heating | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 2331 | Ecomline Excellent | boiler | 206 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 2332 | Ecomline Excellent | boiler | 206 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 2333 | Ecomline Excellent | boiler | 206 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 2334 | Ecomline Excellent | boiler | 206 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 2335 | Ecomline Excellent | boiler | 206 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 2336 | Ecomline Excellent | boiler | 206 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 2337 | Ecomline Excellent | boiler | 206 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 2338 | Ecomline Excellent | boiler | 206 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 2339 | Ecomline Excellent | boiler | 206 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 2340 | Ecomline Excellent | boiler | 206 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 2341 | Ecomline Excellent | boiler | 206 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 2342 | Ecomline Excellent | boiler | 206 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 2343 | Ecomline Excellent | boiler | 206 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 2344 | Ecomline Excellent | boiler | 206 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 2345 | Ecomline Excellent | boiler | 206 | wwtempecoplus | selected eco+ temperature | uint (>=0<=254) | C | true | number.boiler_selected_eco+_temperature | number.boiler_wwtempecoplus |
| 2346 | Ecomline Excellent | boiler | 206 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 2347 | Ecomline Excellent | boiler | 206 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 2348 | Ecomline Excellent | boiler | 206 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 2349 | Ecomline Excellent | boiler | 206 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 2350 | Ecomline Excellent | boiler | 206 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 2351 | Ecomline Excellent | boiler | 206 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 2352 | Ecomline Excellent | boiler | 206 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 2353 | Ecomline Excellent | boiler | 206 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 2354 | Ecomline Excellent | boiler | 206 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 2355 | Ecomline Excellent | boiler | 206 | wwmaxtemp | maximum temperature | uint (>=0<=80) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 2356 | Ecomline Excellent | boiler | 206 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 2357 | Ecomline Excellent | boiler | 206 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 2358 | Ecomline Excellent | boiler | 206 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 2359 | Ecomline Excellent | boiler | 206 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 2360 | Ecomline Excellent | boiler | 206 | wwdisinfectiontemp | disinfection temperature | uint (>=60<=80) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 2361 | Ecomline Excellent | boiler | 206 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 2362 | Ecomline Excellent | boiler | 206 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 2363 | Ecomline Excellent | boiler | 206 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 2364 | Ecomline Excellent | boiler | 206 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 2365 | Ecomline Excellent | boiler | 206 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 2366 | Ecomline Excellent | boiler | 206 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 2367 | Ecomline Excellent | boiler | 206 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 2368 | Ecomline Excellent | boiler | 206 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 2369 | Ecomline Excellent | boiler | 206 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 2370 | Ecomline Excellent | boiler | 206 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 2371 | Ecomline Excellent | boiler | 206 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 2372 | Ecomline Excellent | boiler | 206 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 2373 | Ecomline Excellent | boiler | 206 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 2374 | Ecomline Excellent | boiler | 206 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 2375 | Ecomline Excellent | boiler | 206 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 2376 | Ecomline Excellent | boiler | 206 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 2377 | Ecomline Excellent | boiler | 206 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 2378 | Ecomline Excellent | boiler | 206 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 2379 | Ecomline Excellent | boiler | 206 | wwstarts | starts | ulong (>=0<=16777213) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 2380 | Ecomline Excellent | boiler | 206 | wwworkm | active time | time (>=0<=16777213) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 2381 | Ecomline Excellent | boiler | 206 | nompower | nominal Power | uint (>=0<=254) | kW | true | number.boiler_nominal_Power | number.boiler_nompower |
| 2382 | Ecomline Excellent | boiler | 206 | nrgtotal | total energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
| 2383 | Ecomline Excellent | boiler | 206 | nrgheat | energy heating | ulong (>=0<=10000000) | kWh | true | number.boiler_energy_heating | number.boiler_nrgheat |
| 2384 | Ecomline Excellent | boiler | 206 | nrgww | energy | ulong (>=0<=10000000) | kWh | true | number.boiler_energy | number.boiler_nrgww |
| 2385 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 2386 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 2387 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 2388 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 2389 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 2390 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 2391 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 2392 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 2393 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 2394 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 2395 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 2396 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 2397 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 2398 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 2399 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 2400 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 2401 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 2402 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 2403 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 2404 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 2405 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 2406 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 2407 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burnminperiod | burner min period | uint (>=0<=120) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 2408 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 2409 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatblock | heating block | ushort (>=0<=3199) | C | false | sensor.boiler_heating_block | sensor.boiler_heatblock |
| 2410 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | boilhyston | hysteresis on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 2411 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | boilhystoff | hysteresis off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 2412 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 2413 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatingtemp | heating temperature | uint (>=0<=90) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 2414 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 2415 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 2416 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 2417 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 2418 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | pumpdelay | pump delay | uint (>=0<=60) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 2419 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 2420 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 2421 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 2422 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 2423 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burnstarts | burner starts | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 2424 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burnworkmin | total burner operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 2425 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burn2workmin | burner stage 2 operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 2426 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatworkmin | total heat operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 2427 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatstarts | burner starts heating | ulong (>=0<=16777213) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 2428 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | ubauptime | total UBA operating time | time (>=0<=16777213) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 2429 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 2430 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 2431 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 2432 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 2433 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 2434 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 2435 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 2436 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 2437 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 2438 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 2439 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 2440 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 2441 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 2442 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwtempecoplus | selected eco+ temperature | uint (>=0<=254) | C | true | number.boiler_selected_eco+_temperature | number.boiler_wwtempecoplus |
| 2443 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 2444 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 2445 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 2446 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 2447 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 2448 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 2449 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 2450 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 2451 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 2452 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwmaxtemp | maximum temperature | uint (>=0<=80) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 2453 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 2454 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 2455 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 2456 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 2457 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwdisinfectiontemp | disinfection temperature | uint (>=60<=80) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 2458 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 2459 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 2460 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 2461 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 2462 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 2463 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 2464 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 2465 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 2466 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 2467 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 2468 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 2469 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 2470 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 2471 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 2472 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 2473 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 2474 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 2475 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 2476 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwstarts | starts | ulong (>=0<=16777213) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 2477 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwworkm | active time | time (>=0<=16777213) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 2478 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | nompower | nominal Power | uint (>=0<=254) | kW | true | number.boiler_nominal_Power | number.boiler_nompower |
| 2479 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | nrgtotal | total energy | ulong (>=0<=167772) | kWh | false | sensor.boiler_total_energy | sensor.boiler_nrgtotal |
| 2480 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | nrgheat | energy heating | ulong (>=0<=10000000) | kWh | true | number.boiler_energy_heating | number.boiler_nrgheat |
| 2481 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | nrgww | energy | ulong (>=0<=10000000) | kWh | true | number.boiler_energy | number.boiler_nrgww |
| 2482 | Cascade MC400 | boiler | 210 | reset | reset | cmd [-\|maintenance\|error] | true | sensor.boiler_reset | sensor.boiler_reset | |
| 2483 | Cascade MC400 | boiler | 210 | heatingoff | force heating off | boolean | true | switch.boiler_force_heating_off | switch.boiler_heatingoff | |
| 2484 | Cascade MC400 | boiler | 210 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 2485 | Cascade MC400 | boiler | 210 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 2486 | Cascade MC400 | boiler | 210 | selflowtemp | selected flow temperature | uint (>=0<=90) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 2487 | Cascade MC400 | boiler | 210 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 2488 | Cascade MC400 | boiler | 210 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 2489 | Cascade MC400 | boiler | 210 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 2490 | Cascade MC400 | boiler | 210 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 2491 | Cascade MC400 | boiler | 210 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 2492 | Cascade MC400 | boiler | 210 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 2493 | Cascade MC400 | boiler | 210 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 2494 | Cascade MC400 | boiler | 210 | headertemp | low loss header | ushort (>=0<=3199) | C | false | sensor.boiler_low_loss_header | sensor.boiler_headertemp |
| 2495 | Cascade MC400 | boiler | 210 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 2496 | Cascade MC400 | boiler | 210 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 2497 | Cascade MC400 | boiler | 210 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 2498 | Cascade MC400 | boiler | 210 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 2499 | Cascade MC400 | boiler | 210 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 2500 | Cascade MC400 | boiler | 210 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork |