Files
EMS-ESP32/CHANGELOG_LATEST.md
2024-07-30 15:07:45 +02:00

3.8 KiB

Changelog

[3.7.0]

IMPORTANT! BREAKING CHANGES with 3.6.5

  • new device WATER shows dhw entities from MM100 and SM100 in dhw setting
  • renamed WWC to DHW, always create DHW nests/topics, remove ww prefix from mqtt names #1634
  • change temperaturesensor id to underscore
  • system/info API command has it's JSON keys and names changed to camelCase

Added

  • some more entities for dhw with SM100 module
  • thermostat second dhw circuit #1634
  • remote thermostat emulation for RC100H, RC200 and FB10 #1287, #1602, #1551
  • heatpump dhw stop temperatures #1624
  • reset history #1695
  • heatpump entities fan and shutdown #1690
  • mqtt HA-mode 3 for v3.6 compatible HA entities, set on update v3.6->v3.7
  • HP input states #1723
  • holiday settings for rego 3000 #1735
  • Added scripts for OTA (scripts/upload.py and upload_cli.py) #1738
  • timeout for remote thermostat emulation #1680, #1774
  • CR120 thermostat as own model() #1779
  • modules - external linkable module library #1778
  • scheduler onChange and Conditions #1806
  • make remote control timeout editable #1774
  • added extra pump characteristics (mode and pressure for EMS+) by @SLTKA #1802
  • allow device name to be customized #1174
  • Modbus support by @mheyse #1744
  • System Message command #1854
  • scheduler can use web get/post for values and commands #1806
  • RT800 remote emulation #1867
  • RC310 cooling parameters #1857
  • command api/device/entities #1897

Fixed

  • remote thermostat emulation for RC200 on Rego2000/3000 thermostats #1691
  • log shows data for F7/F9 requests

Changed

  • use flag for BC400 compatible thermostats, manage different mode settings
  • use factory partition for 16M flash
  • store digital out states to nvs
  • Refresh UI - moving settings to one location #1665
  • rename DeviceValueTypes, add UINT32 for custom entities
  • dynamic register dhw circuits for thermostat
  • removed OTA feature #1738
  • added shower min duration #1801
  • Include TXT file along with the generated CSV for Device Data export/download
  • thermostat/remotetemp as command #1835
  • temperaturesensor id notation with underscore #1794
  • Change key-names in JSON to be compliant and consistent #1860