1device namedevice typeproduct idshortnamefullnametype [options...] \| (min/max)uomwriteablediscovery entityid v3.4discovery entityidmodbus unit identifiermodbus blockmodbus scale factormodbus offsetmodbus count
2CS5800i/CS6800i/WLW1x6iboiler8resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
3CS5800i/CS6800i/WLW1x6iboiler8heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
4CS5800i/CS6800i/WLW1x6iboiler8heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
5CS5800i/CS6800i/WLW1x6iboiler8tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
6CS5800i/CS6800i/WLW1x6iboiler8selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
7CS5800i/CS6800i/WLW1x6iboiler8heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
8CS5800i/CS6800i/WLW1x6iboiler8outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
9CS5800i/CS6800i/WLW1x6iboiler8curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
10CS5800i/CS6800i/WLW1x6iboiler8rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
11CS5800i/CS6800i/WLW1x6iboiler8switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
12CS5800i/CS6800i/WLW1x6iboiler8syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
13CS5800i/CS6800i/WLW1x6iboiler8boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
14CS5800i/CS6800i/WLW1x6iboiler8headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
15CS5800i/CS6800i/WLW1x6iboiler8heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
16CS5800i/CS6800i/WLW1x6iboiler8heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
17CS5800i/CS6800i/WLW1x6iboiler8heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
18CS5800i/CS6800i/WLW1x6iboiler8pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
19CS5800i/CS6800i/WLW1x6iboiler8pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
20CS5800i/CS6800i/WLW1x6iboiler8pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
21CS5800i/CS6800i/WLW1x6iboiler8pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
22CS5800i/CS6800i/WLW1x6iboiler8pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
23CS5800i/CS6800i/WLW1x6iboiler8selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
24CS5800i/CS6800i/WLW1x6iboiler8curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
25CS5800i/CS6800i/WLW1x6iboiler8burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
26CS5800i/CS6800i/WLW1x6iboiler8burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
27CS5800i/CS6800i/WLW1x6iboiler8burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
28CS5800i/CS6800i/WLW1x6iboiler8heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
29CS5800i/CS6800i/WLW1x6iboiler8heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
30CS5800i/CS6800i/WLW1x6iboiler8ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
31CS5800i/CS6800i/WLW1x6iboiler8lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
32CS5800i/CS6800i/WLW1x6iboiler8servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
33CS5800i/CS6800i/WLW1x6iboiler8servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
34CS5800i/CS6800i/WLW1x6iboiler8maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
35CS5800i/CS6800i/WLW1x6iboiler8maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
36CS5800i/CS6800i/WLW1x6iboiler8maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
37CS5800i/CS6800i/WLW1x6iboiler8maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
38CS5800i/CS6800i/WLW1x6iboiler8emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
39CS5800i/CS6800i/WLW1x6iboiler8emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
40CS5800i/CS6800i/WLW1x6iboiler8nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
41CS5800i/CS6800i/WLW1x6iboiler8nrgenergyuint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_energysensor.boiler_dhw_nrg591/10002
42CS5800i/CS6800i/WLW1x6iboiler8nrgheatenergy heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_heatingsensor.boiler_nrgheat501/100822
43CS5800i/CS6800i/WLW1x6iboiler8nrgcoolenergy coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_coolingsensor.boiler_nrgcool501/1002642
44CS5800i/CS6800i/WLW1x6iboiler8metertotalmeter totaluint24 (>=0<=167772)kWhfalsesensor.boiler_meter_totalsensor.boiler_metertotal501/100842
45CS5800i/CS6800i/WLW1x6iboiler8metercompmeter compressoruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_compressorsensor.boiler_metercomp501/100862
46CS5800i/CS6800i/WLW1x6iboiler8metereheatmeter e-heateruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_e-heatersensor.boiler_metereheat501/100882
47CS5800i/CS6800i/WLW1x6iboiler8meterheatmeter heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/100902
48CS5800i/CS6800i/WLW1x6iboiler8metercoolmeter coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_coolingsensor.boiler_metercool501/1002662
49CS5800i/CS6800i/WLW1x6iboiler8metermeteruint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/10022
50CS5800i/CS6800i/WLW1x6iboiler8uptimetotalheatpump total uptimetime (>=0<=279620)minutesfalsesensor.boiler_heatpump_total_uptimesensor.boiler_uptimetotal501/60922
51CS5800i/CS6800i/WLW1x6iboiler8uptimecontroltotal operating time heattime (>=0<=279620)minutesfalsesensor.boiler_total_operating_time_heatsensor.boiler_uptimecontrol501/60942
52CS5800i/CS6800i/WLW1x6iboiler8uptimecompheatingoperating time compressor heatingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_heatingsensor.boiler_uptimecompheating501/60962
53CS5800i/CS6800i/WLW1x6iboiler8uptimecompcoolingoperating time compressor coolingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_coolingsensor.boiler_uptimecompcooling501/60982
54CS5800i/CS6800i/WLW1x6iboiler8uptimecompoperating time compressortime (>=0<=279620)minutesfalsesensor.boiler_dhw_operating_time_compressorsensor.boiler_dhw_uptimecomp591/6042
55CS5800i/CS6800i/WLW1x6iboiler8uptimecomppooloperating time compressor pooltime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_poolsensor.boiler_uptimecomppool501/601002
56CS5800i/CS6800i/WLW1x6iboiler8totalcompstartstotal compressor control startsuint24 (>=0<=16777213)falsesensor.boiler_total_compressor_control_startssensor.boiler_totalcompstarts5011022
57CS5800i/CS6800i/WLW1x6iboiler8heatingstartsheating control startsuint24 (>=0<=16777213)falsesensor.boiler_heating_control_startssensor.boiler_heatingstarts5011042
58CS5800i/CS6800i/WLW1x6iboiler8coolingstartscooling control startsuint24 (>=0<=16777213)falsesensor.boiler_cooling_control_startssensor.boiler_coolingstarts5011062
59CS5800i/CS6800i/WLW1x6iboiler8starts2control starts2uint24 (>=0<=16777213)falsesensor.boiler_dhw_control_starts2sensor.boiler_dhw_starts259162
60CS5800i/CS6800i/WLW1x6iboiler8poolstartspool control startsuint24 (>=0<=16777213)falsesensor.boiler_pool_control_startssensor.boiler_poolstarts5011082
61CS5800i/CS6800i/WLW1x6iboiler8nrgconstotaltotal energy consumptionuint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_consumptionsensor.boiler_nrgconstotal5011102
62CS5800i/CS6800i/WLW1x6iboiler8nrgconscomptotaltotal energy consumption compressoruint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_consumption_compressorsensor.boiler_nrgconscomptotal5011122
63CS5800i/CS6800i/WLW1x6iboiler8nrgconscompheatingenergy consumption compressor heatinguint24 (>=0<=16777213)kWhfalsesensor.boiler_energy_consumption_compressor_heatingsensor.boiler_nrgconscompheating5011142
64CS5800i/CS6800i/WLW1x6iboiler8nrgconscompenergy consumption compressoruint24 (>=0<=16777213)kWhfalsesensor.boiler_dhw_energy_consumption_compressorsensor.boiler_dhw_nrgconscomp59182
65CS5800i/CS6800i/WLW1x6iboiler8nrgconscompcoolingenergy consumption compressor coolinguint24 (>=0<=16777213)kWhfalsesensor.boiler_energy_consumption_compressor_coolingsensor.boiler_nrgconscompcooling5011162
66CS5800i/CS6800i/WLW1x6iboiler8nrgconscomppoolenergy consumption compressor pooluint24 (>=0<=16777213)kWhfalsesensor.boiler_energy_consumption_compressor_poolsensor.boiler_nrgconscomppool5011182
67CS5800i/CS6800i/WLW1x6iboiler8auxelecheatnrgconstotaltotal aux elec. heater energy consumptionuint24 (>=0<=16777213)kWhfalsesensor.boiler_total_aux_elec._heater_energy_consumptionsensor.boiler_auxelecheatnrgconstotal5011202
68CS5800i/CS6800i/WLW1x6iboiler8auxelecheatnrgconsheatingaux elec. heater energy consumption heatinguint24 (>=0<=16777213)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_heatingsensor.boiler_auxelecheatnrgconsheating5011222
69CS5800i/CS6800i/WLW1x6iboiler8auxelecheatnrgconsaux elec. heater energy consumptionuint24 (>=0<=16777213)kWhfalsesensor.boiler_dhw_aux_elec._heater_energy_consumptionsensor.boiler_dhw_auxelecheatnrgcons591102
70CS5800i/CS6800i/WLW1x6iboiler8auxelecheatnrgconspoolaux elec. heater energy consumption pooluint24 (>=0<=16777213)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_poolsensor.boiler_auxelecheatnrgconspool5011242
71CS5800i/CS6800i/WLW1x6iboiler8nrgsupptotaltotal energy supplieduint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_suppliedsensor.boiler_nrgsupptotal5011262
72CS5800i/CS6800i/WLW1x6iboiler8nrgsuppheatingtotal energy supplied heatinguint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_supplied_heatingsensor.boiler_nrgsuppheating5011282
73CS5800i/CS6800i/WLW1x6iboiler8nrgsupptotal energy warm supplieduint24 (>=0<=16777213)kWhfalsesensor.boiler_dhw_total_energy_warm_suppliedsensor.boiler_dhw_nrgsupp591122
74CS5800i/CS6800i/WLW1x6iboiler8nrgsuppcoolingtotal energy supplied coolinguint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_supplied_coolingsensor.boiler_nrgsuppcooling5011302
75CS5800i/CS6800i/WLW1x6iboiler8nrgsupppooltotal energy supplied pooluint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_supplied_poolsensor.boiler_nrgsupppool5011322
76CS5800i/CS6800i/WLW1x6iboiler8hppowercompressor power outputuint8 (>=0<=25)kWfalsesensor.boiler_compressor_power_outputsensor.boiler_hppower501/101341
77CS5800i/CS6800i/WLW1x6iboiler8hpmaxpowercompressor max poweruint8 (>=0<=100)%truenumber.boiler_compressor_max_powernumber.boiler_hpmaxpower5011351
78CS5800i/CS6800i/WLW1x6iboiler8hpsetdiffpressset differental pressureuint8 (>=150<=750)mbartruenumber.boiler_set_differental_pressurenumber.boiler_hpsetdiffpress50501361
79CS5800i/CS6800i/WLW1x6iboiler8hpcomponhp compressorbooleanfalsebinary_sensor.boiler_hp_compressorbinary_sensor.boiler_hpcompon5011371
80CS5800i/CS6800i/WLW1x6iboiler8hpactivitycompressor activityenum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost]falsesensor.boiler_compressor_activitysensor.boiler_hpactivity5011381
81CS5800i/CS6800i/WLW1x6iboiler8hpbrinepumpspdbrine pump speeduint8 (>=0<=100)%falsesensor.boiler_brine_pump_speedsensor.boiler_hpbrinepumpspd5011391
82CS5800i/CS6800i/WLW1x6iboiler8hpswitchvalveswitch valvebooleanfalsebinary_sensor.boiler_switch_valvebinary_sensor.boiler_hpswitchvalve5011401
83CS5800i/CS6800i/WLW1x6iboiler8hpcompspdcompressor speeduint8 (>=0<=100)%falsesensor.boiler_compressor_speedsensor.boiler_hpcompspd5011411
84CS5800i/CS6800i/WLW1x6iboiler8hpcircspdcirculation pump speeduint8 (>=0<=100)%falsesensor.boiler_circulation_pump_speedsensor.boiler_hpcircspd5011421
85CS5800i/CS6800i/WLW1x6iboiler8hpbrineinbrine in/evaporatorint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_in/evaporatorsensor.boiler_hpbrinein501/101431
86CS5800i/CS6800i/WLW1x6iboiler8hpbrineoutbrine out/condenserint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_out/condensersensor.boiler_hpbrineout501/101441
87CS5800i/CS6800i/WLW1x6iboiler8hptc0heat carrier return (TC0)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_return_(TC0)sensor.boiler_hptc0501/101451
88CS5800i/CS6800i/WLW1x6iboiler8hptc1heat carrier forward (TC1)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_forward_(TC1)sensor.boiler_hptc1501/101461
89CS5800i/CS6800i/WLW1x6iboiler8hptc3condenser temperature (TC3)int16 (>=-3199<=3199)Cfalsesensor.boiler_condenser_temperature_(TC3)sensor.boiler_hptc3501/101471
90CS5800i/CS6800i/WLW1x6iboiler8hptr1compressor temperature (TR1)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_temperature_(TR1)sensor.boiler_hptr1501/101481
91CS5800i/CS6800i/WLW1x6iboiler8hptr3refrigerant temperature liquid side (condenser output) (TR3)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3)sensor.boiler_hptr3501/101491
92CS5800i/CS6800i/WLW1x6iboiler8hptr4evaporator inlet temperature (TR4)int16 (>=-3199<=3199)Cfalsesensor.boiler_evaporator_inlet_temperature_(TR4)sensor.boiler_hptr4501/101501
93CS5800i/CS6800i/WLW1x6iboiler8hptr5compressor inlet temperature (TR5)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_inlet_temperature_(TR5)sensor.boiler_hptr5501/101511
94CS5800i/CS6800i/WLW1x6iboiler8hptr6compressor outlet temperature (TR6)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_outlet_temperature_(TR6)sensor.boiler_hptr6501/101521
95CS5800i/CS6800i/WLW1x6iboiler8hptr7refrigerant temperature gas side (condenser input) (TR7)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7)sensor.boiler_hptr7501/101531
96CS5800i/CS6800i/WLW1x6iboiler8hptl2air inlet temperature (TL2)int16 (>=-3199<=3199)Cfalsesensor.boiler_air_inlet_temperature_(TL2)sensor.boiler_hptl2501/101541
97CS5800i/CS6800i/WLW1x6iboiler8hppl1low pressure side temperature (PL1)int16 (>=-3199<=3199)Cfalsesensor.boiler_low_pressure_side_temperature_(PL1)sensor.boiler_hppl1501/101551
98CS5800i/CS6800i/WLW1x6iboiler8hpph1high pressure side temperature (PH1)int16 (>=-3199<=3199)Cfalsesensor.boiler_high_pressure_side_temperature_(PH1)sensor.boiler_hpph1501/101561
99CS5800i/CS6800i/WLW1x6iboiler8hpta4drain pan temp (TA4)int16 (>=-3199<=3199)Cfalsesensor.boiler_drain_pan_temp_(TA4)sensor.boiler_hpta4501/101571
100CS5800i/CS6800i/WLW1x6iboiler8hptw1reservoir temp (TW1)int16 (>=-3199<=3199)Cfalsesensor.boiler_reservoir_temp_(TW1)sensor.boiler_hptw1501/101581
101CS5800i/CS6800i/WLW1x6iboiler8poolsettemppool set temperatureuint8 (>=0<=127)Ctruenumber.boiler_pool_set_temperaturenumber.boiler_poolsettemp501/21591
102CS5800i/CS6800i/WLW1x6iboiler8hp4way4-way valve (VR4)enum [cooling & defrost\|heating & dhw]falsesensor.boiler_4-way_valve_(VR4)sensor.boiler_hp4way5011601
103CS5800i/CS6800i/WLW1x6iboiler8hpin1input 1 statebooleanfalsebinary_sensor.boiler_input_1_statebinary_sensor.boiler_hpin15011611
104CS5800i/CS6800i/WLW1x6iboiler8hpin1optinput 1 optionsstringtruesensor.boiler_input_1_optionssensor.boiler_hpin1opt5011628
105CS5800i/CS6800i/WLW1x6iboiler8hpin2input 2 statebooleanfalsebinary_sensor.boiler_input_2_statebinary_sensor.boiler_hpin25011701
106CS5800i/CS6800i/WLW1x6iboiler8hpin2optinput 2 optionsstringtruesensor.boiler_input_2_optionssensor.boiler_hpin2opt5011718
107CS5800i/CS6800i/WLW1x6iboiler8hpin3input 3 statebooleanfalsebinary_sensor.boiler_input_3_statebinary_sensor.boiler_hpin35011791
108CS5800i/CS6800i/WLW1x6iboiler8hpin3optinput 3 optionsstringtruesensor.boiler_input_3_optionssensor.boiler_hpin3opt5011808
109CS5800i/CS6800i/WLW1x6iboiler8hpin4input 4 statebooleanfalsebinary_sensor.boiler_input_4_statebinary_sensor.boiler_hpin45011881
110CS5800i/CS6800i/WLW1x6iboiler8hpin4optinput 4 optionsstringtruesensor.boiler_input_4_optionssensor.boiler_hpin4opt5011898
111CS5800i/CS6800i/WLW1x6iboiler8maxheatcompheat limit compressorenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_compressorselect.boiler_maxheatcomp5011971
112CS5800i/CS6800i/WLW1x6iboiler8maxheatheatheat limit heatingenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_heatingselect.boiler_maxheatheat5011981
113CS5800i/CS6800i/WLW1x6iboiler8maxheatheat limitenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_dhw_heat_limitselect.boiler_dhw_maxheat591141
114CS5800i/CS6800i/WLW1x6iboiler8mandefrostmanual defrostbooleantrueswitch.boiler_manual_defrostswitch.boiler_mandefrost5011991
115CS5800i/CS6800i/WLW1x6iboiler8pvcoolingcooling only with PVbooleantrueswitch.boiler_cooling_only_with_PVswitch.boiler_pvcooling5012001
116CS5800i/CS6800i/WLW1x6iboiler8auxheateronlyaux heater onlybooleantrueswitch.boiler_aux_heater_onlyswitch.boiler_auxheateronly5012011
117CS5800i/CS6800i/WLW1x6iboiler8auxheateroffdisable aux heaterbooleantrueswitch.boiler_disable_aux_heaterswitch.boiler_auxheateroff5012021
118CS5800i/CS6800i/WLW1x6iboiler8auxheaterstatusaux heater statusuint8 (>=0<=100)%falsesensor.boiler_aux_heater_statussensor.boiler_auxheaterstatus5012031
119CS5800i/CS6800i/WLW1x6iboiler8auxheaterdelayaux heater on delayuint16 (>=10<=1000)K*mintruenumber.boiler_aux_heater_on_delaynumber.boiler_auxheaterdelay50102041
120CS5800i/CS6800i/WLW1x6iboiler8auxmaxlimitaux heater max limituint8 (>=0<=10)Ktruenumber.boiler_aux_heater_max_limitnumber.boiler_auxmaxlimit501/102051
121CS5800i/CS6800i/WLW1x6iboiler8auxlimitstartaux heater limit startuint8 (>=0<=10)Ktruenumber.boiler_aux_heater_limit_startnumber.boiler_auxlimitstart501/102061
122CS5800i/CS6800i/WLW1x6iboiler8auxheatrmodeaux heater modeenum [eco\|comfort]trueselect.boiler_aux_heater_modeselect.boiler_auxheatrmode5012071
123CS5800i/CS6800i/WLW1x6iboiler8hphystheaton/off hyst heatuint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_heatnumber.boiler_hphystheat5052081
124CS5800i/CS6800i/WLW1x6iboiler8hphystcoolon/off hyst cooluint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_coolnumber.boiler_hphystcool5052091
125CS5800i/CS6800i/WLW1x6iboiler8hphystpoolon/off hyst pooluint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_poolnumber.boiler_hphystpool5052101
126CS5800i/CS6800i/WLW1x6iboiler8silentmodesilent modeenum [off\|auto\|on]trueselect.boiler_silent_modeselect.boiler_silentmode5012111
127CS5800i/CS6800i/WLW1x6iboiler8silentfromsilent mode fromuint8 (>=0<=3810)minutestruenumber.boiler_silent_mode_fromnumber.boiler_silentfrom50152121
128CS5800i/CS6800i/WLW1x6iboiler8silenttosilent mode touint8 (>=0<=3810)minutestruenumber.boiler_silent_mode_tonumber.boiler_silentto50152131
129CS5800i/CS6800i/WLW1x6iboiler8mintempsilentmin outside temp for silent modeint8 (>=-126<=126)Ctruenumber.boiler_min_outside_temp_for_silent_modenumber.boiler_mintempsilent5012141
130CS5800i/CS6800i/WLW1x6iboiler8tempparmodeoutside temp parallel modeint8 (>=-126<=126)Ctruenumber.boiler_outside_temp_parallel_modenumber.boiler_tempparmode5012151
131CS5800i/CS6800i/WLW1x6iboiler8auxheatmixaux heater mixing valveint8 (>=-100<=100)%falsesensor.boiler_aux_heater_mixing_valvesensor.boiler_auxheatmix5012161
132CS5800i/CS6800i/WLW1x6iboiler8tempdiffheattemp diff TC3/TC0 heatuint8 (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_heatnumber.boiler_tempdiffheat501/102171
133CS5800i/CS6800i/WLW1x6iboiler8tempdiffcooltemp diff TC3/TC0 cooluint8 (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_coolnumber.boiler_tempdiffcool501/102181
134CS5800i/CS6800i/WLW1x6iboiler8vpcoolingvalve/pump coolingbooleantrueswitch.boiler_valve/pump_coolingswitch.boiler_vpcooling5012191
135CS5800i/CS6800i/WLW1x6iboiler8heatcableheating cablebooleantrueswitch.boiler_heating_cableswitch.boiler_heatcable5012201
136CS5800i/CS6800i/WLW1x6iboiler8vc0valveVC0 valvebooleantrueswitch.boiler_VC0_valveswitch.boiler_vc0valve5012211
137CS5800i/CS6800i/WLW1x6iboiler8primepumpprimary heatpumpbooleantrueswitch.boiler_primary_heatpumpswitch.boiler_primepump5012221
138CS5800i/CS6800i/WLW1x6iboiler8primepumpmodprimary heatpump modulationuint8 (>=0<=100)%truenumber.boiler_primary_heatpump_modulationnumber.boiler_primepumpmod5012231
139CS5800i/CS6800i/WLW1x6iboiler8hp3way3-way valvebooleantrueswitch.boiler_3-way_valveswitch.boiler_hp3way5012241
140CS5800i/CS6800i/WLW1x6iboiler8elheatstep1el. heater step 1booleantrueswitch.boiler_el._heater_step_1switch.boiler_elheatstep15012251
141CS5800i/CS6800i/WLW1x6iboiler8elheatstep2el. heater step 2booleantrueswitch.boiler_el._heater_step_2switch.boiler_elheatstep25012261
142CS5800i/CS6800i/WLW1x6iboiler8elheatstep3el. heater step 3booleantrueswitch.boiler_el._heater_step_3switch.boiler_elheatstep35012271
143CS5800i/CS6800i/WLW1x6iboiler8hpea0condensate reservoir heating (EA0)booleanfalsebinary_sensor.boiler_condensate_reservoir_heating_(EA0)binary_sensor.boiler_hpea05012281
144CS5800i/CS6800i/WLW1x6iboiler8hppumpmodeprimary heatpump modeenum [auto\|continuous]trueselect.boiler_primary_heatpump_modeselect.boiler_hppumpmode5012291
145CS5800i/CS6800i/WLW1x6iboiler8fanfanuint8 (>=20<=100)%truenumber.boiler_fannumber.boiler_fan5012301
146CS5800i/CS6800i/WLW1x6iboiler8shutdownshutdowncmd [off\|on]truesensor.boiler_shutdownsensor.boiler_shutdown5012311
147CS5800i/CS6800i/WLW1x6iboiler8hpcurrpowercompressor current poweruint16 (>=0<=31999)Wfalsesensor.boiler_compressor_current_powersensor.boiler_hpcurrpower5012681
148CS5800i/CS6800i/WLW1x6iboiler8hppowerlimitpower limituint16 (>=0<=31999)Wtruenumber.boiler_power_limitnumber.boiler_hppowerlimit5012691
149CS5800i/CS6800i/WLW1x6iboiler8pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow5012701
150CS5800i/CS6800i/WLW1x6iboiler8pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow5012711
151CS5800i/CS6800i/WLW1x6iboiler8pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on5012721
152CS5800i/CS6800i/WLW1x6iboiler8pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate5012731
153CS5800i/CS6800i/WLW1x6iboiler8alternatingopalternating operationbooleantrueswitch.boiler_dhw_alternating_operationswitch.boiler_dhw_alternatingop591151
154CS5800i/CS6800i/WLW1x6iboiler8altopprioheatprioritise heating during dhwuint8 (>=20<=120)minutestruenumber.boiler_dhw_prioritise_heating_during_dhwnumber.boiler_dhw_altopprioheat591161
155CS5800i/CS6800i/WLW1x6iboiler8altopprioprioritise dhw during heatinguint8 (>=30<=120)minutestruenumber.boiler_dhw_prioritise_dhw_during_heatingnumber.boiler_dhw_altopprio591171
156CS5800i/CS6800i/WLW1x6iboiler8comfoffcomfort switch offuint8 (>=15<=65)Ctruenumber.boiler_dhw_comfort_switch_offnumber.boiler_dhw_comfoff591181
157CS5800i/CS6800i/WLW1x6iboiler8ecooffeco switch offuint8 (>=15<=65)Ctruenumber.boiler_dhw_eco_switch_offnumber.boiler_dhw_ecooff591191
158CS5800i/CS6800i/WLW1x6iboiler8ecoplusoffeco+ switch offuint8 (>=48<=63)Ctruenumber.boiler_dhw_eco+_switch_offnumber.boiler_dhw_ecoplusoff591201
159CS5800i/CS6800i/WLW1x6iboiler8comfdiffcomfort diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_comfort_diffnumber.boiler_dhw_comfdiff591211
160CS5800i/CS6800i/WLW1x6iboiler8ecodiffeco diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_eco_diffnumber.boiler_dhw_ecodiff591221
161CS5800i/CS6800i/WLW1x6iboiler8ecoplusdiffeco+ diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_eco+_diffnumber.boiler_dhw_ecoplusdiff591231
162CS5800i/CS6800i/WLW1x6iboiler8comfstopcomfort stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_comfort_stop_tempnumber.boiler_dhw_comfstop591241
163CS5800i/CS6800i/WLW1x6iboiler8ecostopeco stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_eco_stop_tempnumber.boiler_dhw_ecostop591251
164CS5800i/CS6800i/WLW1x6iboiler8ecoplusstopeco+ stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_eco+_stop_tempnumber.boiler_dhw_ecoplusstop591261
165CS5800i/CS6800i/WLW1x6iboiler8hpcircpumpcirculation pump available during dhwbooleantrueswitch.boiler_dhw_circulation_pump_available_during_dhwswitch.boiler_dhw_hpcircpump591271
166CS5800i/CS6800i/WLW1x6iboiler8tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
167CS5800i/CS6800i/WLW1x6iboiler8settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
168CS5800i/CS6800i/WLW1x6iboiler8seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
169CS5800i/CS6800i/WLW1x6iboiler8seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
170CS5800i/CS6800i/WLW1x6iboiler8tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
171CS5800i/CS6800i/WLW1x6iboiler8seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
172CS5800i/CS6800i/WLW1x6iboiler8seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
173CS5800i/CS6800i/WLW1x6iboiler8solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
174CS5800i/CS6800i/WLW1x6iboiler8typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
175CS5800i/CS6800i/WLW1x6iboiler8comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
176CS5800i/CS6800i/WLW1x6iboiler8comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
177CS5800i/CS6800i/WLW1x6iboiler8flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
178CS5800i/CS6800i/WLW1x6iboiler8chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
179CS5800i/CS6800i/WLW1x6iboiler8maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
180CS5800i/CS6800i/WLW1x6iboiler8maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
181CS5800i/CS6800i/WLW1x6iboiler8circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
182CS5800i/CS6800i/WLW1x6iboiler8chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
183CS5800i/CS6800i/WLW1x6iboiler8hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
184CS5800i/CS6800i/WLW1x6iboiler8hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
185CS5800i/CS6800i/WLW1x6iboiler8disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
186CS5800i/CS6800i/WLW1x6iboiler8circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
187CS5800i/CS6800i/WLW1x6iboiler8circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
188CS5800i/CS6800i/WLW1x6iboiler8curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
189CS5800i/CS6800i/WLW1x6iboiler8curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
190CS5800i/CS6800i/WLW1x6iboiler8curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
191CS5800i/CS6800i/WLW1x6iboiler8storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
192CS5800i/CS6800i/WLW1x6iboiler8storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
193CS5800i/CS6800i/WLW1x6iboiler8activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
194CS5800i/CS6800i/WLW1x6iboiler8onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
195CS5800i/CS6800i/WLW1x6iboiler8disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
196CS5800i/CS6800i/WLW1x6iboiler8chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
197CS5800i/CS6800i/WLW1x6iboiler8rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
198CS5800i/CS6800i/WLW1x6iboiler8tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
199CS5800i/CS6800i/WLW1x6iboiler8activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
200CS5800i/CS6800i/WLW1x6iboiler83wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
201CS5800i/CS6800i/WLW1x6iboiler8mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
202CS5800i/CS6800i/WLW1x6iboiler8cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
203CS5800i/CS6800i/WLW1x6iboiler8startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
204CS5800i/CS6800i/WLW1x6iboiler8workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
205C1200Wboiler12resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
206C1200Wboiler12heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
207C1200Wboiler12heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
208C1200Wboiler12tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
209C1200Wboiler12selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
210C1200Wboiler12heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
211C1200Wboiler12outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
212C1200Wboiler12curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
213C1200Wboiler12rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
214C1200Wboiler12switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
215C1200Wboiler12syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
216C1200Wboiler12boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
217C1200Wboiler12headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
218C1200Wboiler12exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
219C1200Wboiler12burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
220C1200Wboiler12burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
221C1200Wboiler12flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
222C1200Wboiler12fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
223C1200Wboiler12ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
224C1200Wboiler12oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
225C1200Wboiler12burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
226C1200Wboiler12burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
227C1200Wboiler12burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
228C1200Wboiler12absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
229C1200Wboiler12heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
230C1200Wboiler12boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
231C1200Wboiler12boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
232C1200Wboiler12boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
233C1200Wboiler12boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
234C1200Wboiler12curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
235C1200Wboiler12curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
236C1200Wboiler12curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
237C1200Wboiler12summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
238C1200Wboiler12nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
239C1200Wboiler12nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
240C1200Wboiler12heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
241C1200Wboiler12heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
242C1200Wboiler12heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
243C1200Wboiler12pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
244C1200Wboiler12pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
245C1200Wboiler12pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
246C1200Wboiler12pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
247C1200Wboiler12pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
248C1200Wboiler12selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
249C1200Wboiler12curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
250C1200Wboiler12burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
251C1200Wboiler12burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
252C1200Wboiler12burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
253C1200Wboiler12heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
254C1200Wboiler12heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
255C1200Wboiler12ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
256C1200Wboiler12lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
257C1200Wboiler12servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
258C1200Wboiler12servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
259C1200Wboiler12maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
260C1200Wboiler12maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
261C1200Wboiler12maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
262C1200Wboiler12maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
263C1200Wboiler12emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
264C1200Wboiler12emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
265C1200Wboiler12meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
266C1200Wboiler12metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
267C1200Wboiler12gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
268C1200Wboiler12gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
269C1200Wboiler12nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
270C1200Wboiler12nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
271C1200Wboiler12tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
272C1200Wboiler12settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
273C1200Wboiler12seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
274C1200Wboiler12seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
275C1200Wboiler12tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
276C1200Wboiler12seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
277C1200Wboiler12seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
278C1200Wboiler12solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
279C1200Wboiler12typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
280C1200Wboiler12comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
281C1200Wboiler12comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
282C1200Wboiler12flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
283C1200Wboiler12chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
284C1200Wboiler12maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
285C1200Wboiler12maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
286C1200Wboiler12circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
287C1200Wboiler12chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
288C1200Wboiler12hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
289C1200Wboiler12hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
290C1200Wboiler12disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
291C1200Wboiler12circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
292C1200Wboiler12circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
293C1200Wboiler12curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
294C1200Wboiler12curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
295C1200Wboiler12curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
296C1200Wboiler12storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
297C1200Wboiler12storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
298C1200Wboiler12activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
299C1200Wboiler12onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
300C1200Wboiler12disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
301C1200Wboiler12chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
302C1200Wboiler12rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
303C1200Wboiler12tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
304C1200Wboiler12activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
305C1200Wboiler123wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
306C1200Wboiler12mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
307C1200Wboiler12cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
308C1200Wboiler12startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
309C1200Wboiler12workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
310C1200Wboiler12nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
311C1200Wboiler12nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
312C1200Wboiler12nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
313C1200Wboiler12nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
314BK13/BK15/Smartline/GB1x2boiler64resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
315BK13/BK15/Smartline/GB1x2boiler64heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
316BK13/BK15/Smartline/GB1x2boiler64heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
317BK13/BK15/Smartline/GB1x2boiler64tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
318BK13/BK15/Smartline/GB1x2boiler64selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
319BK13/BK15/Smartline/GB1x2boiler64heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
320BK13/BK15/Smartline/GB1x2boiler64outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
321BK13/BK15/Smartline/GB1x2boiler64curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
322BK13/BK15/Smartline/GB1x2boiler64rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
323BK13/BK15/Smartline/GB1x2boiler64switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
324BK13/BK15/Smartline/GB1x2boiler64syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
325BK13/BK15/Smartline/GB1x2boiler64boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
326BK13/BK15/Smartline/GB1x2boiler64headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
327BK13/BK15/Smartline/GB1x2boiler64exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
328BK13/BK15/Smartline/GB1x2boiler64burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
329BK13/BK15/Smartline/GB1x2boiler64burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
330BK13/BK15/Smartline/GB1x2boiler64flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
331BK13/BK15/Smartline/GB1x2boiler64fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
332BK13/BK15/Smartline/GB1x2boiler64ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
333BK13/BK15/Smartline/GB1x2boiler64oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
334BK13/BK15/Smartline/GB1x2boiler64burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
335BK13/BK15/Smartline/GB1x2boiler64burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
336BK13/BK15/Smartline/GB1x2boiler64burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
337BK13/BK15/Smartline/GB1x2boiler64absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
338BK13/BK15/Smartline/GB1x2boiler64heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
339BK13/BK15/Smartline/GB1x2boiler64boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
340BK13/BK15/Smartline/GB1x2boiler64boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
341BK13/BK15/Smartline/GB1x2boiler64boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
342BK13/BK15/Smartline/GB1x2boiler64boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
343BK13/BK15/Smartline/GB1x2boiler64curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
344BK13/BK15/Smartline/GB1x2boiler64curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
345BK13/BK15/Smartline/GB1x2boiler64curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
346BK13/BK15/Smartline/GB1x2boiler64summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
347BK13/BK15/Smartline/GB1x2boiler64nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
348BK13/BK15/Smartline/GB1x2boiler64nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
349BK13/BK15/Smartline/GB1x2boiler64heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
350BK13/BK15/Smartline/GB1x2boiler64heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
351BK13/BK15/Smartline/GB1x2boiler64heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
352BK13/BK15/Smartline/GB1x2boiler64pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
353BK13/BK15/Smartline/GB1x2boiler64pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
354BK13/BK15/Smartline/GB1x2boiler64pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
355BK13/BK15/Smartline/GB1x2boiler64pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
356BK13/BK15/Smartline/GB1x2boiler64pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
357BK13/BK15/Smartline/GB1x2boiler64selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
358BK13/BK15/Smartline/GB1x2boiler64curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
359BK13/BK15/Smartline/GB1x2boiler64burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
360BK13/BK15/Smartline/GB1x2boiler64burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
361BK13/BK15/Smartline/GB1x2boiler64burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
362BK13/BK15/Smartline/GB1x2boiler64heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
363BK13/BK15/Smartline/GB1x2boiler64heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
364BK13/BK15/Smartline/GB1x2boiler64ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
365BK13/BK15/Smartline/GB1x2boiler64lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
366BK13/BK15/Smartline/GB1x2boiler64servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
367BK13/BK15/Smartline/GB1x2boiler64servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
368BK13/BK15/Smartline/GB1x2boiler64maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
369BK13/BK15/Smartline/GB1x2boiler64maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
370BK13/BK15/Smartline/GB1x2boiler64maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
371BK13/BK15/Smartline/GB1x2boiler64maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
372BK13/BK15/Smartline/GB1x2boiler64emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
373BK13/BK15/Smartline/GB1x2boiler64emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
374BK13/BK15/Smartline/GB1x2boiler64meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
375BK13/BK15/Smartline/GB1x2boiler64metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
376BK13/BK15/Smartline/GB1x2boiler64gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
377BK13/BK15/Smartline/GB1x2boiler64gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
378BK13/BK15/Smartline/GB1x2boiler64nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
379BK13/BK15/Smartline/GB1x2boiler64nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
380BK13/BK15/Smartline/GB1x2boiler64tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
381BK13/BK15/Smartline/GB1x2boiler64settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
382BK13/BK15/Smartline/GB1x2boiler64seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
383BK13/BK15/Smartline/GB1x2boiler64seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
384BK13/BK15/Smartline/GB1x2boiler64tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
385BK13/BK15/Smartline/GB1x2boiler64seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
386BK13/BK15/Smartline/GB1x2boiler64seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
387BK13/BK15/Smartline/GB1x2boiler64solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
388BK13/BK15/Smartline/GB1x2boiler64typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
389BK13/BK15/Smartline/GB1x2boiler64comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
390BK13/BK15/Smartline/GB1x2boiler64comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
391BK13/BK15/Smartline/GB1x2boiler64flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
392BK13/BK15/Smartline/GB1x2boiler64chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
393BK13/BK15/Smartline/GB1x2boiler64maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
394BK13/BK15/Smartline/GB1x2boiler64maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
395BK13/BK15/Smartline/GB1x2boiler64circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
396BK13/BK15/Smartline/GB1x2boiler64chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
397BK13/BK15/Smartline/GB1x2boiler64hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
398BK13/BK15/Smartline/GB1x2boiler64hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
399BK13/BK15/Smartline/GB1x2boiler64disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
400BK13/BK15/Smartline/GB1x2boiler64circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
401BK13/BK15/Smartline/GB1x2boiler64circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
402BK13/BK15/Smartline/GB1x2boiler64curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
403BK13/BK15/Smartline/GB1x2boiler64curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
404BK13/BK15/Smartline/GB1x2boiler64curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
405BK13/BK15/Smartline/GB1x2boiler64storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
406BK13/BK15/Smartline/GB1x2boiler64storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
407BK13/BK15/Smartline/GB1x2boiler64activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
408BK13/BK15/Smartline/GB1x2boiler64onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
409BK13/BK15/Smartline/GB1x2boiler64disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
410BK13/BK15/Smartline/GB1x2boiler64chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
411BK13/BK15/Smartline/GB1x2boiler64rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
412BK13/BK15/Smartline/GB1x2boiler64tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
413BK13/BK15/Smartline/GB1x2boiler64activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
414BK13/BK15/Smartline/GB1x2boiler643wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
415BK13/BK15/Smartline/GB1x2boiler64mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
416BK13/BK15/Smartline/GB1x2boiler64cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
417BK13/BK15/Smartline/GB1x2boiler64startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
418BK13/BK15/Smartline/GB1x2boiler64workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
419BK13/BK15/Smartline/GB1x2boiler64nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
420BK13/BK15/Smartline/GB1x2boiler64nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
421BK13/BK15/Smartline/GB1x2boiler64nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
422BK13/BK15/Smartline/GB1x2boiler64nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
423GB125/GB135/MC10boiler72resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
424GB125/GB135/MC10boiler72heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
425GB125/GB135/MC10boiler72heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
426GB125/GB135/MC10boiler72tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
427GB125/GB135/MC10boiler72selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
428GB125/GB135/MC10boiler72heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
429GB125/GB135/MC10boiler72outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
430GB125/GB135/MC10boiler72curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
431GB125/GB135/MC10boiler72rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
432GB125/GB135/MC10boiler72switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
433GB125/GB135/MC10boiler72syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
434GB125/GB135/MC10boiler72boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
435GB125/GB135/MC10boiler72headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
436GB125/GB135/MC10boiler72exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
437GB125/GB135/MC10boiler72burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
438GB125/GB135/MC10boiler72burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
439GB125/GB135/MC10boiler72flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
440GB125/GB135/MC10boiler72fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
441GB125/GB135/MC10boiler72ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
442GB125/GB135/MC10boiler72oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
443GB125/GB135/MC10boiler72burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
444GB125/GB135/MC10boiler72burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
445GB125/GB135/MC10boiler72burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
446GB125/GB135/MC10boiler72absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
447GB125/GB135/MC10boiler72heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
448GB125/GB135/MC10boiler72boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
449GB125/GB135/MC10boiler72boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
450GB125/GB135/MC10boiler72boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
451GB125/GB135/MC10boiler72boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
452GB125/GB135/MC10boiler72curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
453GB125/GB135/MC10boiler72curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
454GB125/GB135/MC10boiler72curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
455GB125/GB135/MC10boiler72summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
456GB125/GB135/MC10boiler72nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
457GB125/GB135/MC10boiler72nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
458GB125/GB135/MC10boiler72heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
459GB125/GB135/MC10boiler72heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
460GB125/GB135/MC10boiler72heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
461GB125/GB135/MC10boiler72pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
462GB125/GB135/MC10boiler72pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
463GB125/GB135/MC10boiler72pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
464GB125/GB135/MC10boiler72pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
465GB125/GB135/MC10boiler72pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
466GB125/GB135/MC10boiler72selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
467GB125/GB135/MC10boiler72curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
468GB125/GB135/MC10boiler72burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
469GB125/GB135/MC10boiler72burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
470GB125/GB135/MC10boiler72burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
471GB125/GB135/MC10boiler72heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
472GB125/GB135/MC10boiler72heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
473GB125/GB135/MC10boiler72ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
474GB125/GB135/MC10boiler72lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
475GB125/GB135/MC10boiler72servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
476GB125/GB135/MC10boiler72servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
477GB125/GB135/MC10boiler72maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
478GB125/GB135/MC10boiler72maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
479GB125/GB135/MC10boiler72maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
480GB125/GB135/MC10boiler72maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
481GB125/GB135/MC10boiler72emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
482GB125/GB135/MC10boiler72emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
483GB125/GB135/MC10boiler72meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
484GB125/GB135/MC10boiler72metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
485GB125/GB135/MC10boiler72gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
486GB125/GB135/MC10boiler72gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
487GB125/GB135/MC10boiler72nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
488GB125/GB135/MC10boiler72nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
489GB125/GB135/MC10boiler72tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
490GB125/GB135/MC10boiler72settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
491GB125/GB135/MC10boiler72seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
492GB125/GB135/MC10boiler72seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
493GB125/GB135/MC10boiler72tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
494GB125/GB135/MC10boiler72seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
495GB125/GB135/MC10boiler72seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
496GB125/GB135/MC10boiler72solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
497GB125/GB135/MC10boiler72typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
498GB125/GB135/MC10boiler72comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
499GB125/GB135/MC10boiler72comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
500GB125/GB135/MC10boiler72flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
501GB125/GB135/MC10boiler72chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
502GB125/GB135/MC10boiler72maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
503GB125/GB135/MC10boiler72maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
504GB125/GB135/MC10boiler72circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
505GB125/GB135/MC10boiler72chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
506GB125/GB135/MC10boiler72hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
507GB125/GB135/MC10boiler72hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
508GB125/GB135/MC10boiler72disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
509GB125/GB135/MC10boiler72circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
510GB125/GB135/MC10boiler72circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
511GB125/GB135/MC10boiler72curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
512GB125/GB135/MC10boiler72curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
513GB125/GB135/MC10boiler72curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
514GB125/GB135/MC10boiler72storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
515GB125/GB135/MC10boiler72storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
516GB125/GB135/MC10boiler72activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
517GB125/GB135/MC10boiler72onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
518GB125/GB135/MC10boiler72disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
519GB125/GB135/MC10boiler72chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
520GB125/GB135/MC10boiler72rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
521GB125/GB135/MC10boiler72tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
522GB125/GB135/MC10boiler72activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
523GB125/GB135/MC10boiler723wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
524GB125/GB135/MC10boiler72mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
525GB125/GB135/MC10boiler72cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
526GB125/GB135/MC10boiler72startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
527GB125/GB135/MC10boiler72workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
528GB125/GB135/MC10boiler72nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
529GB125/GB135/MC10boiler72nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
530GB125/GB135/MC10boiler72nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
531GB125/GB135/MC10boiler72nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
532Cascade CM10boiler81resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
533Cascade CM10boiler81heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
534Cascade CM10boiler81heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
535Cascade CM10boiler81tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
536Cascade CM10boiler81selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
537Cascade CM10boiler81heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
538Cascade CM10boiler81outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
539Cascade CM10boiler81curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
540Cascade CM10boiler81rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
541Cascade CM10boiler81switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
542Cascade CM10boiler81syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
543Cascade CM10boiler81boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
544Cascade CM10boiler81headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
545Cascade CM10boiler81exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
546Cascade CM10boiler81burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
547Cascade CM10boiler81burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
548Cascade CM10boiler81flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
549Cascade CM10boiler81fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
550Cascade CM10boiler81ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
551Cascade CM10boiler81oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
552Cascade CM10boiler81burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
553Cascade CM10boiler81burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
554Cascade CM10boiler81burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
555Cascade CM10boiler81absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
556Cascade CM10boiler81heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
557Cascade CM10boiler81boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
558Cascade CM10boiler81boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
559Cascade CM10boiler81boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
560Cascade CM10boiler81boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
561Cascade CM10boiler81curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
562Cascade CM10boiler81curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
563Cascade CM10boiler81curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
564Cascade CM10boiler81summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
565Cascade CM10boiler81nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
566Cascade CM10boiler81nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
567Cascade CM10boiler81heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
568Cascade CM10boiler81heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
569Cascade CM10boiler81heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
570Cascade CM10boiler81pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
571Cascade CM10boiler81pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
572Cascade CM10boiler81pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
573Cascade CM10boiler81pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
574Cascade CM10boiler81pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
575Cascade CM10boiler81selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
576Cascade CM10boiler81curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
577Cascade CM10boiler81burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
578Cascade CM10boiler81burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
579Cascade CM10boiler81burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
580Cascade CM10boiler81heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
581Cascade CM10boiler81heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
582Cascade CM10boiler81ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
583Cascade CM10boiler81lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
584Cascade CM10boiler81servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
585Cascade CM10boiler81servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
586Cascade CM10boiler81maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
587Cascade CM10boiler81maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
588Cascade CM10boiler81maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
589Cascade CM10boiler81maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
590Cascade CM10boiler81emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
591Cascade CM10boiler81emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
592Cascade CM10boiler81meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
593Cascade CM10boiler81metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
594Cascade CM10boiler81gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
595Cascade CM10boiler81gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
596Cascade CM10boiler81nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
597Cascade CM10boiler81nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
598Cascade CM10boiler81tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
599Cascade CM10boiler81settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
600Cascade CM10boiler81seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
601Cascade CM10boiler81seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
602Cascade CM10boiler81tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
603Cascade CM10boiler81seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
604Cascade CM10boiler81seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
605Cascade CM10boiler81solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
606Cascade CM10boiler81typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
607Cascade CM10boiler81comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
608Cascade CM10boiler81comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
609Cascade CM10boiler81flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
610Cascade CM10boiler81chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
611Cascade CM10boiler81maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
612Cascade CM10boiler81maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
613Cascade CM10boiler81circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
614Cascade CM10boiler81chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
615Cascade CM10boiler81hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
616Cascade CM10boiler81hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
617Cascade CM10boiler81disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
618Cascade CM10boiler81circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
619Cascade CM10boiler81circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
620Cascade CM10boiler81curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
621Cascade CM10boiler81curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
622Cascade CM10boiler81curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
623Cascade CM10boiler81storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
624Cascade CM10boiler81storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
625Cascade CM10boiler81activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
626Cascade CM10boiler81onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
627Cascade CM10boiler81disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
628Cascade CM10boiler81chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
629Cascade CM10boiler81rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
630Cascade CM10boiler81tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
631Cascade CM10boiler81activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
632Cascade CM10boiler813wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
633Cascade CM10boiler81mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
634Cascade CM10boiler81cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
635Cascade CM10boiler81startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
636Cascade CM10boiler81workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
637Cascade CM10boiler81nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
638Cascade CM10boiler81nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
639Cascade CM10boiler81nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
640Cascade CM10boiler81nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
641Logamax Plus GB022boiler84resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
642Logamax Plus GB022boiler84heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
643Logamax Plus GB022boiler84heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
644Logamax Plus GB022boiler84tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
645Logamax Plus GB022boiler84selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
646Logamax Plus GB022boiler84heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
647Logamax Plus GB022boiler84outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
648Logamax Plus GB022boiler84curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
649Logamax Plus GB022boiler84rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
650Logamax Plus GB022boiler84switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
651Logamax Plus GB022boiler84syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
652Logamax Plus GB022boiler84boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
653Logamax Plus GB022boiler84headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
654Logamax Plus GB022boiler84exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
655Logamax Plus GB022boiler84burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
656Logamax Plus GB022boiler84burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
657Logamax Plus GB022boiler84flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
658Logamax Plus GB022boiler84fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
659Logamax Plus GB022boiler84ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
660Logamax Plus GB022boiler84oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
661Logamax Plus GB022boiler84burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
662Logamax Plus GB022boiler84burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
663Logamax Plus GB022boiler84burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
664Logamax Plus GB022boiler84absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
665Logamax Plus GB022boiler84heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
666Logamax Plus GB022boiler84boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
667Logamax Plus GB022boiler84boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
668Logamax Plus GB022boiler84boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
669Logamax Plus GB022boiler84boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
670Logamax Plus GB022boiler84curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
671Logamax Plus GB022boiler84curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
672Logamax Plus GB022boiler84curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
673Logamax Plus GB022boiler84summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
674Logamax Plus GB022boiler84nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
675Logamax Plus GB022boiler84nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
676Logamax Plus GB022boiler84heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
677Logamax Plus GB022boiler84heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
678Logamax Plus GB022boiler84heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
679Logamax Plus GB022boiler84pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
680Logamax Plus GB022boiler84pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
681Logamax Plus GB022boiler84pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
682Logamax Plus GB022boiler84pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
683Logamax Plus GB022boiler84pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
684Logamax Plus GB022boiler84selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
685Logamax Plus GB022boiler84curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
686Logamax Plus GB022boiler84burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
687Logamax Plus GB022boiler84burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
688Logamax Plus GB022boiler84burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
689Logamax Plus GB022boiler84heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
690Logamax Plus GB022boiler84heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
691Logamax Plus GB022boiler84ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
692Logamax Plus GB022boiler84lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
693Logamax Plus GB022boiler84servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
694Logamax Plus GB022boiler84servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
695Logamax Plus GB022boiler84maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
696Logamax Plus GB022boiler84maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
697Logamax Plus GB022boiler84maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
698Logamax Plus GB022boiler84maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
699Logamax Plus GB022boiler84emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
700Logamax Plus GB022boiler84emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
701Logamax Plus GB022boiler84meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
702Logamax Plus GB022boiler84metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
703Logamax Plus GB022boiler84gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
704Logamax Plus GB022boiler84gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
705Logamax Plus GB022boiler84nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
706Logamax Plus GB022boiler84nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
707Logamax Plus GB022boiler84tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
708Logamax Plus GB022boiler84settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
709Logamax Plus GB022boiler84seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
710Logamax Plus GB022boiler84seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
711Logamax Plus GB022boiler84tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
712Logamax Plus GB022boiler84seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
713Logamax Plus GB022boiler84seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
714Logamax Plus GB022boiler84solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
715Logamax Plus GB022boiler84typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
716Logamax Plus GB022boiler84comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
717Logamax Plus GB022boiler84comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
718Logamax Plus GB022boiler84flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
719Logamax Plus GB022boiler84chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
720Logamax Plus GB022boiler84maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
721Logamax Plus GB022boiler84maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
722Logamax Plus GB022boiler84circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
723Logamax Plus GB022boiler84chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
724Logamax Plus GB022boiler84hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
725Logamax Plus GB022boiler84hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
726Logamax Plus GB022boiler84disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
727Logamax Plus GB022boiler84circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
728Logamax Plus GB022boiler84circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
729Logamax Plus GB022boiler84curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
730Logamax Plus GB022boiler84curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
731Logamax Plus GB022boiler84curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
732Logamax Plus GB022boiler84storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
733Logamax Plus GB022boiler84storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
734Logamax Plus GB022boiler84activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
735Logamax Plus GB022boiler84onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
736Logamax Plus GB022boiler84disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
737Logamax Plus GB022boiler84chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
738Logamax Plus GB022boiler84rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
739Logamax Plus GB022boiler84tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
740Logamax Plus GB022boiler84activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
741Logamax Plus GB022boiler843wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
742Logamax Plus GB022boiler84mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
743Logamax Plus GB022boiler84cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
744Logamax Plus GB022boiler84startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
745Logamax Plus GB022boiler84workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
746Logamax Plus GB022boiler84nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
747Logamax Plus GB022boiler84nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
748Logamax Plus GB022boiler84nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
749Logamax Plus GB022boiler84nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
750Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
751Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
752Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
753Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
754Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
755Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
756Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
757Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
758Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
759Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
760Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
761Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
762Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
763Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
764Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
765Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
766Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
767Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
768Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
769Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
770Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
771Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
772Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
773Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
774Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
775Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
776Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
777Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
778Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
779Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
780Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
781Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
782Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
783Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
784Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
785Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
786Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
787Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
788Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
789Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
790Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
791Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
792Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
793Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
794Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
795Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
796Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
797Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
798Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
799Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
800Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
801Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
802Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
803Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
804Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
805Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
806Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
807Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
808Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
809Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
810Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
811Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
812Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
813Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
814Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
815Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
816Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
817Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
818Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
819Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
820Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
821Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
822Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
823Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
824Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
825Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
826Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
827Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
828Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
829Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
830Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
831Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
832Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
833Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
834Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
835Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
836Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
837Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
838Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
839Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
840Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
841Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
842Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
843Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
844Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
845Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
846Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
847Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
848Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
849Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
850Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler953wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
851Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
852Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
853Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
854Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
855Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
856Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
857Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
858Condens 2500/5000W/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
859Topline/GB162boiler115resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
860Topline/GB162boiler115heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
861Topline/GB162boiler115heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
862Topline/GB162boiler115tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
863Topline/GB162boiler115selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
864Topline/GB162boiler115heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
865Topline/GB162boiler115outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
866Topline/GB162boiler115curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
867Topline/GB162boiler115rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
868Topline/GB162boiler115switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
869Topline/GB162boiler115syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
870Topline/GB162boiler115boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
871Topline/GB162boiler115headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
872Topline/GB162boiler115exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
873Topline/GB162boiler115burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
874Topline/GB162boiler115burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
875Topline/GB162boiler115flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
876Topline/GB162boiler115fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
877Topline/GB162boiler115ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
878Topline/GB162boiler115oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
879Topline/GB162boiler115burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
880Topline/GB162boiler115burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
881Topline/GB162boiler115burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
882Topline/GB162boiler115absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
883Topline/GB162boiler115heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
884Topline/GB162boiler115boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
885Topline/GB162boiler115boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
886Topline/GB162boiler115boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
887Topline/GB162boiler115boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
888Topline/GB162boiler115curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
889Topline/GB162boiler115curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
890Topline/GB162boiler115curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
891Topline/GB162boiler115summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
892Topline/GB162boiler115nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
893Topline/GB162boiler115nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
894Topline/GB162boiler115heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
895Topline/GB162boiler115heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
896Topline/GB162boiler115heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
897Topline/GB162boiler115pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
898Topline/GB162boiler115pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
899Topline/GB162boiler115pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
900Topline/GB162boiler115pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
901Topline/GB162boiler115pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
902Topline/GB162boiler115selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
903Topline/GB162boiler115curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
904Topline/GB162boiler115burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
905Topline/GB162boiler115burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
906Topline/GB162boiler115burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
907Topline/GB162boiler115heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
908Topline/GB162boiler115heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
909Topline/GB162boiler115ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
910Topline/GB162boiler115lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
911Topline/GB162boiler115servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
912Topline/GB162boiler115servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
913Topline/GB162boiler115maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
914Topline/GB162boiler115maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
915Topline/GB162boiler115maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
916Topline/GB162boiler115maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
917Topline/GB162boiler115emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
918Topline/GB162boiler115emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
919Topline/GB162boiler115meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
920Topline/GB162boiler115metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
921Topline/GB162boiler115gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
922Topline/GB162boiler115gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
923Topline/GB162boiler115nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
924Topline/GB162boiler115nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
925Topline/GB162boiler115tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
926Topline/GB162boiler115settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
927Topline/GB162boiler115seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
928Topline/GB162boiler115seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
929Topline/GB162boiler115tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
930Topline/GB162boiler115seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
931Topline/GB162boiler115seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
932Topline/GB162boiler115solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
933Topline/GB162boiler115typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
934Topline/GB162boiler115comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
935Topline/GB162boiler115comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
936Topline/GB162boiler115flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
937Topline/GB162boiler115chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
938Topline/GB162boiler115maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
939Topline/GB162boiler115maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
940Topline/GB162boiler115circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
941Topline/GB162boiler115chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
942Topline/GB162boiler115hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
943Topline/GB162boiler115hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
944Topline/GB162boiler115disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
945Topline/GB162boiler115circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
946Topline/GB162boiler115circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
947Topline/GB162boiler115curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
948Topline/GB162boiler115curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
949Topline/GB162boiler115curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
950Topline/GB162boiler115storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
951Topline/GB162boiler115storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
952Topline/GB162boiler115activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
953Topline/GB162boiler115onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
954Topline/GB162boiler115disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
955Topline/GB162boiler115chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
956Topline/GB162boiler115rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
957Topline/GB162boiler115tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
958Topline/GB162boiler115activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
959Topline/GB162boiler1153wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
960Topline/GB162boiler115mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
961Topline/GB162boiler115cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
962Topline/GB162boiler115startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
963Topline/GB162boiler115workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
964Topline/GB162boiler115nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
965Topline/GB162boiler115nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
966Topline/GB162boiler115nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
967Topline/GB162boiler115nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
968Cascade MCM10boiler121resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
969Cascade MCM10boiler121heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
970Cascade MCM10boiler121heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
971Cascade MCM10boiler121tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
972Cascade MCM10boiler121selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
973Cascade MCM10boiler121heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
974Cascade MCM10boiler121outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
975Cascade MCM10boiler121curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
976Cascade MCM10boiler121rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
977Cascade MCM10boiler121switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
978Cascade MCM10boiler121syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
979Cascade MCM10boiler121boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
980Cascade MCM10boiler121headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
981Cascade MCM10boiler121exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
982Cascade MCM10boiler121burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
983Cascade MCM10boiler121burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
984Cascade MCM10boiler121flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
985Cascade MCM10boiler121fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
986Cascade MCM10boiler121ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
987Cascade MCM10boiler121oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
988Cascade MCM10boiler121burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
989Cascade MCM10boiler121burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
990Cascade MCM10boiler121burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
991Cascade MCM10boiler121absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
992Cascade MCM10boiler121heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
993Cascade MCM10boiler121boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
994Cascade MCM10boiler121boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
995Cascade MCM10boiler121boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
996Cascade MCM10boiler121boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
997Cascade MCM10boiler121curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
998Cascade MCM10boiler121curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
999Cascade MCM10boiler121curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
1000Cascade MCM10boiler121summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
1001Cascade MCM10boiler121nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
1002Cascade MCM10boiler121nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
1003Cascade MCM10boiler121heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1004Cascade MCM10boiler121heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1005Cascade MCM10boiler121heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1006Cascade MCM10boiler121pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1007Cascade MCM10boiler121pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1008Cascade MCM10boiler121pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1009Cascade MCM10boiler121pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1010Cascade MCM10boiler121pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1011Cascade MCM10boiler121selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
1012Cascade MCM10boiler121curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
1013Cascade MCM10boiler121burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
1014Cascade MCM10boiler121burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
1015Cascade MCM10boiler121burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
1016Cascade MCM10boiler121heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
1017Cascade MCM10boiler121heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
1018Cascade MCM10boiler121ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
1019Cascade MCM10boiler121lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
1020Cascade MCM10boiler121servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
1021Cascade MCM10boiler121servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
1022Cascade MCM10boiler121maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
1023Cascade MCM10boiler121maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
1024Cascade MCM10boiler121maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
1025Cascade MCM10boiler121maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
1026Cascade MCM10boiler121emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
1027Cascade MCM10boiler121emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
1028Cascade MCM10boiler121meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
1029Cascade MCM10boiler121metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1030Cascade MCM10boiler121gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
1031Cascade MCM10boiler121gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1032Cascade MCM10boiler121nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
1033Cascade MCM10boiler121nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1034Cascade MCM10boiler121tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1035Cascade MCM10boiler121settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1036Cascade MCM10boiler121seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1037Cascade MCM10boiler121seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1038Cascade MCM10boiler121tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1039Cascade MCM10boiler121seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1040Cascade MCM10boiler121seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1041Cascade MCM10boiler121solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1042Cascade MCM10boiler121typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1043Cascade MCM10boiler121comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1044Cascade MCM10boiler121comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1045Cascade MCM10boiler121flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1046Cascade MCM10boiler121chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1047Cascade MCM10boiler121maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1048Cascade MCM10boiler121maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1049Cascade MCM10boiler121circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1050Cascade MCM10boiler121chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1051Cascade MCM10boiler121hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1052Cascade MCM10boiler121hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1053Cascade MCM10boiler121disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1054Cascade MCM10boiler121circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1055Cascade MCM10boiler121circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1056Cascade MCM10boiler121curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1057Cascade MCM10boiler121curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1058Cascade MCM10boiler121curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1059Cascade MCM10boiler121storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1060Cascade MCM10boiler121storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1061Cascade MCM10boiler121activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1062Cascade MCM10boiler121onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1063Cascade MCM10boiler121disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1064Cascade MCM10boiler121chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1065Cascade MCM10boiler121rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1066Cascade MCM10boiler121tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1067Cascade MCM10boiler121activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1068Cascade MCM10boiler1213wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1069Cascade MCM10boiler121mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1070Cascade MCM10boiler121cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1071Cascade MCM10boiler121startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1072Cascade MCM10boiler121workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1073Cascade MCM10boiler121nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
1074Cascade MCM10boiler121nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
1075Cascade MCM10boiler121nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
1076Cascade MCM10boiler121nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1077Prolineboiler122resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1078Prolineboiler122heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1079Prolineboiler122heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1080Prolineboiler122tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1081Prolineboiler122selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1082Prolineboiler122heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1083Prolineboiler122outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1084Prolineboiler122curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1085Prolineboiler122rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1086Prolineboiler122switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1087Prolineboiler122syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1088Prolineboiler122boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1089Prolineboiler122headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1090Prolineboiler122exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
1091Prolineboiler122burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
1092Prolineboiler122burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
1093Prolineboiler122flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
1094Prolineboiler122fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
1095Prolineboiler122ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
1096Prolineboiler122oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
1097Prolineboiler122burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
1098Prolineboiler122burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
1099Prolineboiler122burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
1100Prolineboiler122absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
1101Prolineboiler122heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
1102Prolineboiler122boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
1103Prolineboiler122boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
1104Prolineboiler122boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
1105Prolineboiler122boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
1106Prolineboiler122curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
1107Prolineboiler122curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
1108Prolineboiler122curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
1109Prolineboiler122summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
1110Prolineboiler122nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
1111Prolineboiler122nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
1112Prolineboiler122heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1113Prolineboiler122heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1114Prolineboiler122heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1115Prolineboiler122pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1116Prolineboiler122pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1117Prolineboiler122pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1118Prolineboiler122pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1119Prolineboiler122pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1120Prolineboiler122selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
1121Prolineboiler122curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
1122Prolineboiler122burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
1123Prolineboiler122burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
1124Prolineboiler122burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
1125Prolineboiler122heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
1126Prolineboiler122heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
1127Prolineboiler122ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
1128Prolineboiler122lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
1129Prolineboiler122servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
1130Prolineboiler122servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
1131Prolineboiler122maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
1132Prolineboiler122maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
1133Prolineboiler122maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
1134Prolineboiler122maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
1135Prolineboiler122emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
1136Prolineboiler122emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
1137Prolineboiler122meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
1138Prolineboiler122metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1139Prolineboiler122gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
1140Prolineboiler122gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1141Prolineboiler122nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
1142Prolineboiler122nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1143Prolineboiler122tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1144Prolineboiler122settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1145Prolineboiler122seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1146Prolineboiler122seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1147Prolineboiler122tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1148Prolineboiler122seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1149Prolineboiler122seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1150Prolineboiler122solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1151Prolineboiler122typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1152Prolineboiler122comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1153Prolineboiler122comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1154Prolineboiler122flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1155Prolineboiler122chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1156Prolineboiler122maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1157Prolineboiler122maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1158Prolineboiler122circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1159Prolineboiler122chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1160Prolineboiler122hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1161Prolineboiler122hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1162Prolineboiler122disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1163Prolineboiler122circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1164Prolineboiler122circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1165Prolineboiler122curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1166Prolineboiler122curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1167Prolineboiler122curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1168Prolineboiler122storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1169Prolineboiler122storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1170Prolineboiler122activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1171Prolineboiler122onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1172Prolineboiler122disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1173Prolineboiler122chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1174Prolineboiler122rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1175Prolineboiler122tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1176Prolineboiler122activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1177Prolineboiler1223wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1178Prolineboiler122mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1179Prolineboiler122cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1180Prolineboiler122startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1181Prolineboiler122workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1182Prolineboiler122nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
1183Prolineboiler122nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
1184Prolineboiler122nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
1185Prolineboiler122nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1186GBx72/Trendline/Cerapur/Greenstar Siboiler123resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1187GBx72/Trendline/Cerapur/Greenstar Siboiler123heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1188GBx72/Trendline/Cerapur/Greenstar Siboiler123heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1189GBx72/Trendline/Cerapur/Greenstar Siboiler123tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1190GBx72/Trendline/Cerapur/Greenstar Siboiler123selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1191GBx72/Trendline/Cerapur/Greenstar Siboiler123heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1192GBx72/Trendline/Cerapur/Greenstar Siboiler123outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1193GBx72/Trendline/Cerapur/Greenstar Siboiler123curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1194GBx72/Trendline/Cerapur/Greenstar Siboiler123rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1195GBx72/Trendline/Cerapur/Greenstar Siboiler123switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1196GBx72/Trendline/Cerapur/Greenstar Siboiler123syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1197GBx72/Trendline/Cerapur/Greenstar Siboiler123boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1198GBx72/Trendline/Cerapur/Greenstar Siboiler123headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1199GBx72/Trendline/Cerapur/Greenstar Siboiler123exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
1200GBx72/Trendline/Cerapur/Greenstar Siboiler123burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
1201GBx72/Trendline/Cerapur/Greenstar Siboiler123burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
1202GBx72/Trendline/Cerapur/Greenstar Siboiler123flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
1203GBx72/Trendline/Cerapur/Greenstar Siboiler123fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
1204GBx72/Trendline/Cerapur/Greenstar Siboiler123ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
1205GBx72/Trendline/Cerapur/Greenstar Siboiler123oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
1206GBx72/Trendline/Cerapur/Greenstar Siboiler123burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
1207GBx72/Trendline/Cerapur/Greenstar Siboiler123burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
1208GBx72/Trendline/Cerapur/Greenstar Siboiler123burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
1209GBx72/Trendline/Cerapur/Greenstar Siboiler123absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
1210GBx72/Trendline/Cerapur/Greenstar Siboiler123heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
1211GBx72/Trendline/Cerapur/Greenstar Siboiler123boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
1212GBx72/Trendline/Cerapur/Greenstar Siboiler123boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
1213GBx72/Trendline/Cerapur/Greenstar Siboiler123boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
1214GBx72/Trendline/Cerapur/Greenstar Siboiler123boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
1215GBx72/Trendline/Cerapur/Greenstar Siboiler123curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
1216GBx72/Trendline/Cerapur/Greenstar Siboiler123curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
1217GBx72/Trendline/Cerapur/Greenstar Siboiler123curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
1218GBx72/Trendline/Cerapur/Greenstar Siboiler123summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
1219GBx72/Trendline/Cerapur/Greenstar Siboiler123nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
1220GBx72/Trendline/Cerapur/Greenstar Siboiler123nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
1221GBx72/Trendline/Cerapur/Greenstar Siboiler123heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1222GBx72/Trendline/Cerapur/Greenstar Siboiler123heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1223GBx72/Trendline/Cerapur/Greenstar Siboiler123heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1224GBx72/Trendline/Cerapur/Greenstar Siboiler123pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1225GBx72/Trendline/Cerapur/Greenstar Siboiler123pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1226GBx72/Trendline/Cerapur/Greenstar Siboiler123pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1227GBx72/Trendline/Cerapur/Greenstar Siboiler123pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1228GBx72/Trendline/Cerapur/Greenstar Siboiler123pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1229GBx72/Trendline/Cerapur/Greenstar Siboiler123selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
1230GBx72/Trendline/Cerapur/Greenstar Siboiler123curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
1231GBx72/Trendline/Cerapur/Greenstar Siboiler123burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
1232GBx72/Trendline/Cerapur/Greenstar Siboiler123burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
1233GBx72/Trendline/Cerapur/Greenstar Siboiler123burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
1234GBx72/Trendline/Cerapur/Greenstar Siboiler123heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
1235GBx72/Trendline/Cerapur/Greenstar Siboiler123heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
1236GBx72/Trendline/Cerapur/Greenstar Siboiler123ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
1237GBx72/Trendline/Cerapur/Greenstar Siboiler123lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
1238GBx72/Trendline/Cerapur/Greenstar Siboiler123servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
1239GBx72/Trendline/Cerapur/Greenstar Siboiler123servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
1240GBx72/Trendline/Cerapur/Greenstar Siboiler123maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
1241GBx72/Trendline/Cerapur/Greenstar Siboiler123maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
1242GBx72/Trendline/Cerapur/Greenstar Siboiler123maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
1243GBx72/Trendline/Cerapur/Greenstar Siboiler123maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
1244GBx72/Trendline/Cerapur/Greenstar Siboiler123emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
1245GBx72/Trendline/Cerapur/Greenstar Siboiler123emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
1246GBx72/Trendline/Cerapur/Greenstar Siboiler123meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
1247GBx72/Trendline/Cerapur/Greenstar Siboiler123metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1248GBx72/Trendline/Cerapur/Greenstar Siboiler123gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
1249GBx72/Trendline/Cerapur/Greenstar Siboiler123gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1250GBx72/Trendline/Cerapur/Greenstar Siboiler123nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
1251GBx72/Trendline/Cerapur/Greenstar Siboiler123nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1252GBx72/Trendline/Cerapur/Greenstar Siboiler123tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1253GBx72/Trendline/Cerapur/Greenstar Siboiler123settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1254GBx72/Trendline/Cerapur/Greenstar Siboiler123seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1255GBx72/Trendline/Cerapur/Greenstar Siboiler123seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1256GBx72/Trendline/Cerapur/Greenstar Siboiler123tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1257GBx72/Trendline/Cerapur/Greenstar Siboiler123seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1258GBx72/Trendline/Cerapur/Greenstar Siboiler123seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1259GBx72/Trendline/Cerapur/Greenstar Siboiler123solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1260GBx72/Trendline/Cerapur/Greenstar Siboiler123typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1261GBx72/Trendline/Cerapur/Greenstar Siboiler123comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1262GBx72/Trendline/Cerapur/Greenstar Siboiler123comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1263GBx72/Trendline/Cerapur/Greenstar Siboiler123flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1264GBx72/Trendline/Cerapur/Greenstar Siboiler123chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1265GBx72/Trendline/Cerapur/Greenstar Siboiler123maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1266GBx72/Trendline/Cerapur/Greenstar Siboiler123maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1267GBx72/Trendline/Cerapur/Greenstar Siboiler123circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1268GBx72/Trendline/Cerapur/Greenstar Siboiler123chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1269GBx72/Trendline/Cerapur/Greenstar Siboiler123hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1270GBx72/Trendline/Cerapur/Greenstar Siboiler123hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1271GBx72/Trendline/Cerapur/Greenstar Siboiler123disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1272GBx72/Trendline/Cerapur/Greenstar Siboiler123circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1273GBx72/Trendline/Cerapur/Greenstar Siboiler123circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1274GBx72/Trendline/Cerapur/Greenstar Siboiler123curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1275GBx72/Trendline/Cerapur/Greenstar Siboiler123curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1276GBx72/Trendline/Cerapur/Greenstar Siboiler123curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1277GBx72/Trendline/Cerapur/Greenstar Siboiler123storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1278GBx72/Trendline/Cerapur/Greenstar Siboiler123storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1279GBx72/Trendline/Cerapur/Greenstar Siboiler123activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1280GBx72/Trendline/Cerapur/Greenstar Siboiler123onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1281GBx72/Trendline/Cerapur/Greenstar Siboiler123disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1282GBx72/Trendline/Cerapur/Greenstar Siboiler123chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1283GBx72/Trendline/Cerapur/Greenstar Siboiler123rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1284GBx72/Trendline/Cerapur/Greenstar Siboiler123tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1285GBx72/Trendline/Cerapur/Greenstar Siboiler123activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1286GBx72/Trendline/Cerapur/Greenstar Siboiler1233wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1287GBx72/Trendline/Cerapur/Greenstar Siboiler123mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1288GBx72/Trendline/Cerapur/Greenstar Siboiler123cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1289GBx72/Trendline/Cerapur/Greenstar Siboiler123startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1290GBx72/Trendline/Cerapur/Greenstar Siboiler123workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1291GBx72/Trendline/Cerapur/Greenstar Siboiler123nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
1292GBx72/Trendline/Cerapur/Greenstar Siboiler123nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
1293GBx72/Trendline/Cerapur/Greenstar Siboiler123nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
1294GBx72/Trendline/Cerapur/Greenstar Siboiler123nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1295GB212boiler131resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1296GB212boiler131heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1297GB212boiler131heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1298GB212boiler131tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1299GB212boiler131selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1300GB212boiler131heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1301GB212boiler131outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1302GB212boiler131curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1303GB212boiler131rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1304GB212boiler131switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1305GB212boiler131syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1306GB212boiler131boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1307GB212boiler131headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1308GB212boiler131exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
1309GB212boiler131burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
1310GB212boiler131burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
1311GB212boiler131flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
1312GB212boiler131fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
1313GB212boiler131ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
1314GB212boiler131oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
1315GB212boiler131burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
1316GB212boiler131burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
1317GB212boiler131burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
1318GB212boiler131absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
1319GB212boiler131heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
1320GB212boiler131boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
1321GB212boiler131boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
1322GB212boiler131boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
1323GB212boiler131boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
1324GB212boiler131curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
1325GB212boiler131curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
1326GB212boiler131curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
1327GB212boiler131summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
1328GB212boiler131nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
1329GB212boiler131nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
1330GB212boiler131heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1331GB212boiler131heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1332GB212boiler131heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1333GB212boiler131pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1334GB212boiler131pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1335GB212boiler131pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1336GB212boiler131pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1337GB212boiler131pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1338GB212boiler131selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
1339GB212boiler131curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
1340GB212boiler131burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
1341GB212boiler131burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
1342GB212boiler131burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
1343GB212boiler131heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
1344GB212boiler131heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
1345GB212boiler131ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
1346GB212boiler131lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
1347GB212boiler131servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
1348GB212boiler131servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
1349GB212boiler131maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
1350GB212boiler131maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
1351GB212boiler131maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
1352GB212boiler131maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
1353GB212boiler131emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
1354GB212boiler131emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
1355GB212boiler131meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
1356GB212boiler131metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1357GB212boiler131gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
1358GB212boiler131gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1359GB212boiler131nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
1360GB212boiler131nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1361GB212boiler131tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1362GB212boiler131settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1363GB212boiler131seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1364GB212boiler131seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1365GB212boiler131tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1366GB212boiler131seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1367GB212boiler131seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1368GB212boiler131solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1369GB212boiler131typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1370GB212boiler131comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1371GB212boiler131comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1372GB212boiler131flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1373GB212boiler131chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1374GB212boiler131maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1375GB212boiler131maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1376GB212boiler131circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1377GB212boiler131chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1378GB212boiler131hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1379GB212boiler131hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1380GB212boiler131disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1381GB212boiler131circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1382GB212boiler131circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1383GB212boiler131curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1384GB212boiler131curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1385GB212boiler131curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1386GB212boiler131storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1387GB212boiler131storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1388GB212boiler131activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1389GB212boiler131onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1390GB212boiler131disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1391GB212boiler131chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1392GB212boiler131rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1393GB212boiler131tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1394GB212boiler131activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1395GB212boiler1313wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1396GB212boiler131mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1397GB212boiler131cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1398GB212boiler131startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1399GB212boiler131workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1400GB212boiler131nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
1401GB212boiler131nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
1402GB212boiler131nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
1403GB212boiler131nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1404GC7000Fboiler132resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1405GC7000Fboiler132heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1406GC7000Fboiler132heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1407GC7000Fboiler132tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1408GC7000Fboiler132selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1409GC7000Fboiler132heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1410GC7000Fboiler132outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1411GC7000Fboiler132curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1412GC7000Fboiler132rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1413GC7000Fboiler132switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1414GC7000Fboiler132syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1415GC7000Fboiler132boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1416GC7000Fboiler132headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1417GC7000Fboiler132exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
1418GC7000Fboiler132burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
1419GC7000Fboiler132burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
1420GC7000Fboiler132flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
1421GC7000Fboiler132fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
1422GC7000Fboiler132ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
1423GC7000Fboiler132oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
1424GC7000Fboiler132burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
1425GC7000Fboiler132burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
1426GC7000Fboiler132burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
1427GC7000Fboiler132absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
1428GC7000Fboiler132heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
1429GC7000Fboiler132boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
1430GC7000Fboiler132boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
1431GC7000Fboiler132boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
1432GC7000Fboiler132boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
1433GC7000Fboiler132curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
1434GC7000Fboiler132curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
1435GC7000Fboiler132curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
1436GC7000Fboiler132summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
1437GC7000Fboiler132nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
1438GC7000Fboiler132nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
1439GC7000Fboiler132heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1440GC7000Fboiler132heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1441GC7000Fboiler132heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1442GC7000Fboiler132pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1443GC7000Fboiler132pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1444GC7000Fboiler132pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1445GC7000Fboiler132pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1446GC7000Fboiler132pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1447GC7000Fboiler132selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
1448GC7000Fboiler132curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
1449GC7000Fboiler132burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
1450GC7000Fboiler132burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
1451GC7000Fboiler132burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
1452GC7000Fboiler132heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
1453GC7000Fboiler132heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
1454GC7000Fboiler132ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
1455GC7000Fboiler132lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
1456GC7000Fboiler132servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
1457GC7000Fboiler132servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
1458GC7000Fboiler132maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
1459GC7000Fboiler132maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
1460GC7000Fboiler132maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
1461GC7000Fboiler132maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
1462GC7000Fboiler132emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
1463GC7000Fboiler132emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
1464GC7000Fboiler132meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
1465GC7000Fboiler132metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1466GC7000Fboiler132gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
1467GC7000Fboiler132gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1468GC7000Fboiler132nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
1469GC7000Fboiler132nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1470GC7000Fboiler132tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1471GC7000Fboiler132settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1472GC7000Fboiler132seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1473GC7000Fboiler132seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1474GC7000Fboiler132tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1475GC7000Fboiler132seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1476GC7000Fboiler132seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1477GC7000Fboiler132solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1478GC7000Fboiler132typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1479GC7000Fboiler132comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1480GC7000Fboiler132comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1481GC7000Fboiler132flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1482GC7000Fboiler132chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1483GC7000Fboiler132maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1484GC7000Fboiler132maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1485GC7000Fboiler132circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1486GC7000Fboiler132chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1487GC7000Fboiler132hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1488GC7000Fboiler132hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1489GC7000Fboiler132disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1490GC7000Fboiler132circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1491GC7000Fboiler132circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1492GC7000Fboiler132curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1493GC7000Fboiler132curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1494GC7000Fboiler132curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1495GC7000Fboiler132storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1496GC7000Fboiler132storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1497GC7000Fboiler132activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1498GC7000Fboiler132onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1499GC7000Fboiler132disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1500GC7000Fboiler132chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1501GC7000Fboiler132rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1502GC7000Fboiler132tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1503GC7000Fboiler132activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1504GC7000Fboiler1323wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1505GC7000Fboiler132mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1506GC7000Fboiler132cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1507GC7000Fboiler132startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1508GC7000Fboiler132workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1509GC7000Fboiler132nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
1510GC7000Fboiler132nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
1511GC7000Fboiler132nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
1512GC7000Fboiler132nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1513Logano GB125/KB195i/Logamatic MC110boiler133resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1514Logano GB125/KB195i/Logamatic MC110boiler133heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1515Logano GB125/KB195i/Logamatic MC110boiler133heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1516Logano GB125/KB195i/Logamatic MC110boiler133tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1517Logano GB125/KB195i/Logamatic MC110boiler133selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1518Logano GB125/KB195i/Logamatic MC110boiler133heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1519Logano GB125/KB195i/Logamatic MC110boiler133outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1520Logano GB125/KB195i/Logamatic MC110boiler133curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1521Logano GB125/KB195i/Logamatic MC110boiler133rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1522Logano GB125/KB195i/Logamatic MC110boiler133switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1523Logano GB125/KB195i/Logamatic MC110boiler133syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1524Logano GB125/KB195i/Logamatic MC110boiler133boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1525Logano GB125/KB195i/Logamatic MC110boiler133headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1526Logano GB125/KB195i/Logamatic MC110boiler133exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
1527Logano GB125/KB195i/Logamatic MC110boiler133burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
1528Logano GB125/KB195i/Logamatic MC110boiler133burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
1529Logano GB125/KB195i/Logamatic MC110boiler133flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
1530Logano GB125/KB195i/Logamatic MC110boiler133fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
1531Logano GB125/KB195i/Logamatic MC110boiler133ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
1532Logano GB125/KB195i/Logamatic MC110boiler133oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
1533Logano GB125/KB195i/Logamatic MC110boiler133burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
1534Logano GB125/KB195i/Logamatic MC110boiler133burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
1535Logano GB125/KB195i/Logamatic MC110boiler133burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
1536Logano GB125/KB195i/Logamatic MC110boiler133absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
1537Logano GB125/KB195i/Logamatic MC110boiler133heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
1538Logano GB125/KB195i/Logamatic MC110boiler133boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
1539Logano GB125/KB195i/Logamatic MC110boiler133boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
1540Logano GB125/KB195i/Logamatic MC110boiler133boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
1541Logano GB125/KB195i/Logamatic MC110boiler133boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
1542Logano GB125/KB195i/Logamatic MC110boiler133curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
1543Logano GB125/KB195i/Logamatic MC110boiler133curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
1544Logano GB125/KB195i/Logamatic MC110boiler133curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
1545Logano GB125/KB195i/Logamatic MC110boiler133summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
1546Logano GB125/KB195i/Logamatic MC110boiler133nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
1547Logano GB125/KB195i/Logamatic MC110boiler133nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
1548Logano GB125/KB195i/Logamatic MC110boiler133heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1549Logano GB125/KB195i/Logamatic MC110boiler133heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1550Logano GB125/KB195i/Logamatic MC110boiler133heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1551Logano GB125/KB195i/Logamatic MC110boiler133pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1552Logano GB125/KB195i/Logamatic MC110boiler133pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1553Logano GB125/KB195i/Logamatic MC110boiler133pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1554Logano GB125/KB195i/Logamatic MC110boiler133pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1555Logano GB125/KB195i/Logamatic MC110boiler133pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1556Logano GB125/KB195i/Logamatic MC110boiler133selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
1557Logano GB125/KB195i/Logamatic MC110boiler133curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
1558Logano GB125/KB195i/Logamatic MC110boiler133burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
1559Logano GB125/KB195i/Logamatic MC110boiler133burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
1560Logano GB125/KB195i/Logamatic MC110boiler133burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
1561Logano GB125/KB195i/Logamatic MC110boiler133heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
1562Logano GB125/KB195i/Logamatic MC110boiler133heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
1563Logano GB125/KB195i/Logamatic MC110boiler133ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
1564Logano GB125/KB195i/Logamatic MC110boiler133lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
1565Logano GB125/KB195i/Logamatic MC110boiler133servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
1566Logano GB125/KB195i/Logamatic MC110boiler133servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
1567Logano GB125/KB195i/Logamatic MC110boiler133maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
1568Logano GB125/KB195i/Logamatic MC110boiler133maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
1569Logano GB125/KB195i/Logamatic MC110boiler133maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
1570Logano GB125/KB195i/Logamatic MC110boiler133maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
1571Logano GB125/KB195i/Logamatic MC110boiler133emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
1572Logano GB125/KB195i/Logamatic MC110boiler133emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
1573Logano GB125/KB195i/Logamatic MC110boiler133meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
1574Logano GB125/KB195i/Logamatic MC110boiler133metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1575Logano GB125/KB195i/Logamatic MC110boiler133gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
1576Logano GB125/KB195i/Logamatic MC110boiler133gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1577Logano GB125/KB195i/Logamatic MC110boiler133nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
1578Logano GB125/KB195i/Logamatic MC110boiler133nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1579Logano GB125/KB195i/Logamatic MC110boiler133tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1580Logano GB125/KB195i/Logamatic MC110boiler133settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1581Logano GB125/KB195i/Logamatic MC110boiler133seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1582Logano GB125/KB195i/Logamatic MC110boiler133seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1583Logano GB125/KB195i/Logamatic MC110boiler133tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1584Logano GB125/KB195i/Logamatic MC110boiler133seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1585Logano GB125/KB195i/Logamatic MC110boiler133seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1586Logano GB125/KB195i/Logamatic MC110boiler133solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1587Logano GB125/KB195i/Logamatic MC110boiler133typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1588Logano GB125/KB195i/Logamatic MC110boiler133comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1589Logano GB125/KB195i/Logamatic MC110boiler133comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1590Logano GB125/KB195i/Logamatic MC110boiler133flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1591Logano GB125/KB195i/Logamatic MC110boiler133chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1592Logano GB125/KB195i/Logamatic MC110boiler133maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1593Logano GB125/KB195i/Logamatic MC110boiler133maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1594Logano GB125/KB195i/Logamatic MC110boiler133circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1595Logano GB125/KB195i/Logamatic MC110boiler133chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1596Logano GB125/KB195i/Logamatic MC110boiler133hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1597Logano GB125/KB195i/Logamatic MC110boiler133hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1598Logano GB125/KB195i/Logamatic MC110boiler133disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1599Logano GB125/KB195i/Logamatic MC110boiler133circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1600Logano GB125/KB195i/Logamatic MC110boiler133circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1601Logano GB125/KB195i/Logamatic MC110boiler133curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1602Logano GB125/KB195i/Logamatic MC110boiler133curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1603Logano GB125/KB195i/Logamatic MC110boiler133curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1604Logano GB125/KB195i/Logamatic MC110boiler133storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1605Logano GB125/KB195i/Logamatic MC110boiler133storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1606Logano GB125/KB195i/Logamatic MC110boiler133activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1607Logano GB125/KB195i/Logamatic MC110boiler133onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1608Logano GB125/KB195i/Logamatic MC110boiler133disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1609Logano GB125/KB195i/Logamatic MC110boiler133chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1610Logano GB125/KB195i/Logamatic MC110boiler133rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1611Logano GB125/KB195i/Logamatic MC110boiler133tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1612Logano GB125/KB195i/Logamatic MC110boiler133activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1613Logano GB125/KB195i/Logamatic MC110boiler1333wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1614Logano GB125/KB195i/Logamatic MC110boiler133mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1615Logano GB125/KB195i/Logamatic MC110boiler133cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1616Logano GB125/KB195i/Logamatic MC110boiler133startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1617Logano GB125/KB195i/Logamatic MC110boiler133workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1618Logano GB125/KB195i/Logamatic MC110boiler133nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
1619Logano GB125/KB195i/Logamatic MC110boiler133nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
1620Logano GB125/KB195i/Logamatic MC110boiler133nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
1621Logano GB125/KB195i/Logamatic MC110boiler133nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1622Greenstar 30Ri Compactboiler154resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1623Greenstar 30Ri Compactboiler154heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1624Greenstar 30Ri Compactboiler154heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1625Greenstar 30Ri Compactboiler154tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1626Greenstar 30Ri Compactboiler154selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1627Greenstar 30Ri Compactboiler154heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1628Greenstar 30Ri Compactboiler154outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1629Greenstar 30Ri Compactboiler154curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1630Greenstar 30Ri Compactboiler154rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1631Greenstar 30Ri Compactboiler154switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1632Greenstar 30Ri Compactboiler154syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1633Greenstar 30Ri Compactboiler154boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1634Greenstar 30Ri Compactboiler154headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1635Greenstar 30Ri Compactboiler154exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
1636Greenstar 30Ri Compactboiler154burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
1637Greenstar 30Ri Compactboiler154burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
1638Greenstar 30Ri Compactboiler154flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
1639Greenstar 30Ri Compactboiler154fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
1640Greenstar 30Ri Compactboiler154ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
1641Greenstar 30Ri Compactboiler154oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
1642Greenstar 30Ri Compactboiler154burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
1643Greenstar 30Ri Compactboiler154burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
1644Greenstar 30Ri Compactboiler154burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
1645Greenstar 30Ri Compactboiler154absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
1646Greenstar 30Ri Compactboiler154heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
1647Greenstar 30Ri Compactboiler154boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
1648Greenstar 30Ri Compactboiler154boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
1649Greenstar 30Ri Compactboiler154boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
1650Greenstar 30Ri Compactboiler154boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
1651Greenstar 30Ri Compactboiler154curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
1652Greenstar 30Ri Compactboiler154curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
1653Greenstar 30Ri Compactboiler154curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
1654Greenstar 30Ri Compactboiler154summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
1655Greenstar 30Ri Compactboiler154nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
1656Greenstar 30Ri Compactboiler154nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
1657Greenstar 30Ri Compactboiler154heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1658Greenstar 30Ri Compactboiler154heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1659Greenstar 30Ri Compactboiler154heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1660Greenstar 30Ri Compactboiler154pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1661Greenstar 30Ri Compactboiler154pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1662Greenstar 30Ri Compactboiler154pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1663Greenstar 30Ri Compactboiler154pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1664Greenstar 30Ri Compactboiler154pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1665Greenstar 30Ri Compactboiler154selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
1666Greenstar 30Ri Compactboiler154curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
1667Greenstar 30Ri Compactboiler154burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
1668Greenstar 30Ri Compactboiler154burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
1669Greenstar 30Ri Compactboiler154burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
1670Greenstar 30Ri Compactboiler154heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
1671Greenstar 30Ri Compactboiler154heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
1672Greenstar 30Ri Compactboiler154ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
1673Greenstar 30Ri Compactboiler154lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
1674Greenstar 30Ri Compactboiler154servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
1675Greenstar 30Ri Compactboiler154servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
1676Greenstar 30Ri Compactboiler154maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
1677Greenstar 30Ri Compactboiler154maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
1678Greenstar 30Ri Compactboiler154maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
1679Greenstar 30Ri Compactboiler154maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
1680Greenstar 30Ri Compactboiler154emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
1681Greenstar 30Ri Compactboiler154emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
1682Greenstar 30Ri Compactboiler154meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
1683Greenstar 30Ri Compactboiler154metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1684Greenstar 30Ri Compactboiler154gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
1685Greenstar 30Ri Compactboiler154gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1686Greenstar 30Ri Compactboiler154nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
1687Greenstar 30Ri Compactboiler154nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1688Greenstar 30Ri Compactboiler154tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1689Greenstar 30Ri Compactboiler154settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1690Greenstar 30Ri Compactboiler154seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1691Greenstar 30Ri Compactboiler154seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1692Greenstar 30Ri Compactboiler154tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1693Greenstar 30Ri Compactboiler154seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1694Greenstar 30Ri Compactboiler154seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1695Greenstar 30Ri Compactboiler154solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1696Greenstar 30Ri Compactboiler154typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1697Greenstar 30Ri Compactboiler154comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1698Greenstar 30Ri Compactboiler154comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1699Greenstar 30Ri Compactboiler154flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1700Greenstar 30Ri Compactboiler154chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1701Greenstar 30Ri Compactboiler154maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1702Greenstar 30Ri Compactboiler154maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1703Greenstar 30Ri Compactboiler154circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1704Greenstar 30Ri Compactboiler154chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1705Greenstar 30Ri Compactboiler154hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1706Greenstar 30Ri Compactboiler154hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1707Greenstar 30Ri Compactboiler154disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1708Greenstar 30Ri Compactboiler154circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1709Greenstar 30Ri Compactboiler154circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1710Greenstar 30Ri Compactboiler154curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1711Greenstar 30Ri Compactboiler154curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1712Greenstar 30Ri Compactboiler154curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1713Greenstar 30Ri Compactboiler154storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1714Greenstar 30Ri Compactboiler154storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1715Greenstar 30Ri Compactboiler154activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1716Greenstar 30Ri Compactboiler154onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1717Greenstar 30Ri Compactboiler154disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1718Greenstar 30Ri Compactboiler154chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1719Greenstar 30Ri Compactboiler154rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1720Greenstar 30Ri Compactboiler154tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1721Greenstar 30Ri Compactboiler154activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1722Greenstar 30Ri Compactboiler1543wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1723Greenstar 30Ri Compactboiler154mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1724Greenstar 30Ri Compactboiler154cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1725Greenstar 30Ri Compactboiler154startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1726Greenstar 30Ri Compactboiler154workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1727Greenstar 30Ri Compactboiler154nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
1728Greenstar 30Ri Compactboiler154nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
1729Greenstar 30Ri Compactboiler154nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
1730Greenstar 30Ri Compactboiler154nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1731Cerapur Aeroboiler167resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1732Cerapur Aeroboiler167heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1733Cerapur Aeroboiler167heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1734Cerapur Aeroboiler167tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1735Cerapur Aeroboiler167selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1736Cerapur Aeroboiler167heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1737Cerapur Aeroboiler167outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1738Cerapur Aeroboiler167curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1739Cerapur Aeroboiler167rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1740Cerapur Aeroboiler167switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1741Cerapur Aeroboiler167syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1742Cerapur Aeroboiler167boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1743Cerapur Aeroboiler167headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1744Cerapur Aeroboiler167exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
1745Cerapur Aeroboiler167burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
1746Cerapur Aeroboiler167burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
1747Cerapur Aeroboiler167flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
1748Cerapur Aeroboiler167fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
1749Cerapur Aeroboiler167ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
1750Cerapur Aeroboiler167oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
1751Cerapur Aeroboiler167burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
1752Cerapur Aeroboiler167burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
1753Cerapur Aeroboiler167burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
1754Cerapur Aeroboiler167absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
1755Cerapur Aeroboiler167heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
1756Cerapur Aeroboiler167boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
1757Cerapur Aeroboiler167boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
1758Cerapur Aeroboiler167boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
1759Cerapur Aeroboiler167boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
1760Cerapur Aeroboiler167curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
1761Cerapur Aeroboiler167curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
1762Cerapur Aeroboiler167curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
1763Cerapur Aeroboiler167summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
1764Cerapur Aeroboiler167nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
1765Cerapur Aeroboiler167nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
1766Cerapur Aeroboiler167heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1767Cerapur Aeroboiler167heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1768Cerapur Aeroboiler167heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1769Cerapur Aeroboiler167pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1770Cerapur Aeroboiler167pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1771Cerapur Aeroboiler167pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1772Cerapur Aeroboiler167pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1773Cerapur Aeroboiler167pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1774Cerapur Aeroboiler167selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
1775Cerapur Aeroboiler167curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
1776Cerapur Aeroboiler167burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
1777Cerapur Aeroboiler167burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
1778Cerapur Aeroboiler167burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
1779Cerapur Aeroboiler167heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
1780Cerapur Aeroboiler167heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
1781Cerapur Aeroboiler167ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
1782Cerapur Aeroboiler167lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
1783Cerapur Aeroboiler167servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
1784Cerapur Aeroboiler167servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
1785Cerapur Aeroboiler167maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
1786Cerapur Aeroboiler167maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
1787Cerapur Aeroboiler167maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
1788Cerapur Aeroboiler167maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
1789Cerapur Aeroboiler167emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
1790Cerapur Aeroboiler167emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
1791Cerapur Aeroboiler167meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
1792Cerapur Aeroboiler167metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1793Cerapur Aeroboiler167gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
1794Cerapur Aeroboiler167gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1795Cerapur Aeroboiler167nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
1796Cerapur Aeroboiler167nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1797Cerapur Aeroboiler167tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1798Cerapur Aeroboiler167settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1799Cerapur Aeroboiler167seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1800Cerapur Aeroboiler167seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1801Cerapur Aeroboiler167tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1802Cerapur Aeroboiler167seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1803Cerapur Aeroboiler167seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1804Cerapur Aeroboiler167solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1805Cerapur Aeroboiler167typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1806Cerapur Aeroboiler167comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1807Cerapur Aeroboiler167comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1808Cerapur Aeroboiler167flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1809Cerapur Aeroboiler167chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1810Cerapur Aeroboiler167maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1811Cerapur Aeroboiler167maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1812Cerapur Aeroboiler167circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1813Cerapur Aeroboiler167chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1814Cerapur Aeroboiler167hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1815Cerapur Aeroboiler167hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1816Cerapur Aeroboiler167disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1817Cerapur Aeroboiler167circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1818Cerapur Aeroboiler167circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1819Cerapur Aeroboiler167curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1820Cerapur Aeroboiler167curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1821Cerapur Aeroboiler167curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1822Cerapur Aeroboiler167storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1823Cerapur Aeroboiler167storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1824Cerapur Aeroboiler167activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1825Cerapur Aeroboiler167onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1826Cerapur Aeroboiler167disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1827Cerapur Aeroboiler167chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1828Cerapur Aeroboiler167rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1829Cerapur Aeroboiler167tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1830Cerapur Aeroboiler167activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1831Cerapur Aeroboiler1673wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1832Cerapur Aeroboiler167mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1833Cerapur Aeroboiler167cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1834Cerapur Aeroboiler167startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1835Cerapur Aeroboiler167workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1836Cerapur Aeroboiler167nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
1837Cerapur Aeroboiler167nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
1838Cerapur Aeroboiler167nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
1839Cerapur Aeroboiler167nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1840Hybrid Heatpumpboiler168resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1841Hybrid Heatpumpboiler168heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1842Hybrid Heatpumpboiler168heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1843Hybrid Heatpumpboiler168tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1844Hybrid Heatpumpboiler168selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1845Hybrid Heatpumpboiler168heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1846Hybrid Heatpumpboiler168outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1847Hybrid Heatpumpboiler168curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1848Hybrid Heatpumpboiler168rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1849Hybrid Heatpumpboiler168switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1850Hybrid Heatpumpboiler168syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1851Hybrid Heatpumpboiler168boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1852Hybrid Heatpumpboiler168headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1853Hybrid Heatpumpboiler168exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
1854Hybrid Heatpumpboiler168burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
1855Hybrid Heatpumpboiler168burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
1856Hybrid Heatpumpboiler168flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
1857Hybrid Heatpumpboiler168fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
1858Hybrid Heatpumpboiler168ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
1859Hybrid Heatpumpboiler168oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
1860Hybrid Heatpumpboiler168burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
1861Hybrid Heatpumpboiler168burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
1862Hybrid Heatpumpboiler168burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
1863Hybrid Heatpumpboiler168absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
1864Hybrid Heatpumpboiler168heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
1865Hybrid Heatpumpboiler168boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
1866Hybrid Heatpumpboiler168boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
1867Hybrid Heatpumpboiler168boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
1868Hybrid Heatpumpboiler168boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
1869Hybrid Heatpumpboiler168curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
1870Hybrid Heatpumpboiler168curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
1871Hybrid Heatpumpboiler168curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
1872Hybrid Heatpumpboiler168summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
1873Hybrid Heatpumpboiler168nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
1874Hybrid Heatpumpboiler168nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
1875Hybrid Heatpumpboiler168heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1876Hybrid Heatpumpboiler168heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1877Hybrid Heatpumpboiler168heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1878Hybrid Heatpumpboiler168pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1879Hybrid Heatpumpboiler168pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1880Hybrid Heatpumpboiler168pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1881Hybrid Heatpumpboiler168pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1882Hybrid Heatpumpboiler168pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1883Hybrid Heatpumpboiler168selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
1884Hybrid Heatpumpboiler168curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
1885Hybrid Heatpumpboiler168burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
1886Hybrid Heatpumpboiler168burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
1887Hybrid Heatpumpboiler168burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
1888Hybrid Heatpumpboiler168heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
1889Hybrid Heatpumpboiler168heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
1890Hybrid Heatpumpboiler168ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
1891Hybrid Heatpumpboiler168lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
1892Hybrid Heatpumpboiler168servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
1893Hybrid Heatpumpboiler168servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
1894Hybrid Heatpumpboiler168maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
1895Hybrid Heatpumpboiler168maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
1896Hybrid Heatpumpboiler168maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
1897Hybrid Heatpumpboiler168maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
1898Hybrid Heatpumpboiler168emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
1899Hybrid Heatpumpboiler168emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
1900Hybrid Heatpumpboiler168meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
1901Hybrid Heatpumpboiler168metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1902Hybrid Heatpumpboiler168gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
1903Hybrid Heatpumpboiler168gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1904Hybrid Heatpumpboiler168nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
1905Hybrid Heatpumpboiler168nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1906Hybrid Heatpumpboiler168tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1907Hybrid Heatpumpboiler168settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1908Hybrid Heatpumpboiler168seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1909Hybrid Heatpumpboiler168seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1910Hybrid Heatpumpboiler168tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1911Hybrid Heatpumpboiler168seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1912Hybrid Heatpumpboiler168seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1913Hybrid Heatpumpboiler168solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1914Hybrid Heatpumpboiler168typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1915Hybrid Heatpumpboiler168comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1916Hybrid Heatpumpboiler168comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1917Hybrid Heatpumpboiler168flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1918Hybrid Heatpumpboiler168chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1919Hybrid Heatpumpboiler168maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1920Hybrid Heatpumpboiler168maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1921Hybrid Heatpumpboiler168circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1922Hybrid Heatpumpboiler168chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1923Hybrid Heatpumpboiler168hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1924Hybrid Heatpumpboiler168hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1925Hybrid Heatpumpboiler168disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1926Hybrid Heatpumpboiler168circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1927Hybrid Heatpumpboiler168circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1928Hybrid Heatpumpboiler168curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1929Hybrid Heatpumpboiler168curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1930Hybrid Heatpumpboiler168curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1931Hybrid Heatpumpboiler168storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1932Hybrid Heatpumpboiler168storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1933Hybrid Heatpumpboiler168activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1934Hybrid Heatpumpboiler168onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1935Hybrid Heatpumpboiler168disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1936Hybrid Heatpumpboiler168chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1937Hybrid Heatpumpboiler168rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1938Hybrid Heatpumpboiler168tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1939Hybrid Heatpumpboiler168activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1940Hybrid Heatpumpboiler1683wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1941Hybrid Heatpumpboiler168mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1942Hybrid Heatpumpboiler168cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1943Hybrid Heatpumpboiler168startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1944Hybrid Heatpumpboiler168workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1945Hybrid Heatpumpboiler168nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
1946Hybrid Heatpumpboiler168nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
1947Hybrid Heatpumpboiler168nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
1948Hybrid Heatpumpboiler168nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1949Logano GB212boiler170resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1950Logano GB212boiler170heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1951Logano GB212boiler170heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1952Logano GB212boiler170tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1953Logano GB212boiler170selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1954Logano GB212boiler170heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1955Logano GB212boiler170outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1956Logano GB212boiler170curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1957Logano GB212boiler170rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1958Logano GB212boiler170switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1959Logano GB212boiler170syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1960Logano GB212boiler170boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1961Logano GB212boiler170headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1962Logano GB212boiler170exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
1963Logano GB212boiler170burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
1964Logano GB212boiler170burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
1965Logano GB212boiler170flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
1966Logano GB212boiler170fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
1967Logano GB212boiler170ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
1968Logano GB212boiler170oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
1969Logano GB212boiler170burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
1970Logano GB212boiler170burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
1971Logano GB212boiler170burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
1972Logano GB212boiler170absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
1973Logano GB212boiler170heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
1974Logano GB212boiler170boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
1975Logano GB212boiler170boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
1976Logano GB212boiler170boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
1977Logano GB212boiler170boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
1978Logano GB212boiler170curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
1979Logano GB212boiler170curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
1980Logano GB212boiler170curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
1981Logano GB212boiler170summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
1982Logano GB212boiler170nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
1983Logano GB212boiler170nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
1984Logano GB212boiler170heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1985Logano GB212boiler170heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1986Logano GB212boiler170heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1987Logano GB212boiler170pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1988Logano GB212boiler170pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1989Logano GB212boiler170pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1990Logano GB212boiler170pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1991Logano GB212boiler170pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1992Logano GB212boiler170selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
1993Logano GB212boiler170curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
1994Logano GB212boiler170burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
1995Logano GB212boiler170burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
1996Logano GB212boiler170burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
1997Logano GB212boiler170heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
1998Logano GB212boiler170heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
1999Logano GB212boiler170ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
2000Logano GB212boiler170lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
2001Logano GB212boiler170servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
2002Logano GB212boiler170servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
2003Logano GB212boiler170maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
2004Logano GB212boiler170maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
2005Logano GB212boiler170maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
2006Logano GB212boiler170maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
2007Logano GB212boiler170emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
2008Logano GB212boiler170emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
2009Logano GB212boiler170meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
2010Logano GB212boiler170metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
2011Logano GB212boiler170gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
2012Logano GB212boiler170gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
2013Logano GB212boiler170nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
2014Logano GB212boiler170nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
2015Logano GB212boiler170tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
2016Logano GB212boiler170settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
2017Logano GB212boiler170seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
2018Logano GB212boiler170seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
2019Logano GB212boiler170tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
2020Logano GB212boiler170seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
2021Logano GB212boiler170seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
2022Logano GB212boiler170solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
2023Logano GB212boiler170typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
2024Logano GB212boiler170comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
2025Logano GB212boiler170comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
2026Logano GB212boiler170flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
2027Logano GB212boiler170chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
2028Logano GB212boiler170maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
2029Logano GB212boiler170maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
2030Logano GB212boiler170circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
2031Logano GB212boiler170chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
2032Logano GB212boiler170hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
2033Logano GB212boiler170hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
2034Logano GB212boiler170disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
2035Logano GB212boiler170circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
2036Logano GB212boiler170circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
2037Logano GB212boiler170curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
2038Logano GB212boiler170curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
2039Logano GB212boiler170curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
2040Logano GB212boiler170storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
2041Logano GB212boiler170storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
2042Logano GB212boiler170activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
2043Logano GB212boiler170onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
2044Logano GB212boiler170disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
2045Logano GB212boiler170chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
2046Logano GB212boiler170rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
2047Logano GB212boiler170tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
2048Logano GB212boiler170activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
2049Logano GB212boiler1703wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
2050Logano GB212boiler170mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
2051Logano GB212boiler170cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
2052Logano GB212boiler170startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
2053Logano GB212boiler170workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
2054Logano GB212boiler170nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
2055Logano GB212boiler170nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
2056Logano GB212boiler170nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
2057Logano GB212boiler170nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
2058Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
2059Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
2060Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
2061Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
2062Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
2063Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
2064Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
2065Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
2066Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
2067Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
2068Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
2069Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
2070Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
2071Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
2072Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
2073Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
2074Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
2075Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
2076Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
2077Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
2078Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
2079Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
2080Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
2081Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
2082Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
2083Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
2084Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
2085Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
2086Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
2087Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
2088Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
2089Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
2090Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
2091Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
2092Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
2093Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
2094Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
2095Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
2096Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
2097Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgenergyuint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_energysensor.boiler_dhw_nrg591/10002
2098Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgheatenergy heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_heatingsensor.boiler_nrgheat501/100822
2099Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgcoolenergy coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_coolingsensor.boiler_nrgcool501/1002642
2100Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172metertotalmeter totaluint24 (>=0<=167772)kWhfalsesensor.boiler_meter_totalsensor.boiler_metertotal501/100842
2101Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172metercompmeter compressoruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_compressorsensor.boiler_metercomp501/100862
2102Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172metereheatmeter e-heateruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_e-heatersensor.boiler_metereheat501/100882
2103Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172meterheatmeter heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/100902
2104Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172metercoolmeter coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_coolingsensor.boiler_metercool501/1002662
2105Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172metermeteruint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/10022
2106Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172uptimetotalheatpump total uptimetime (>=0<=279620)minutesfalsesensor.boiler_heatpump_total_uptimesensor.boiler_uptimetotal501/60922
2107Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172uptimecontroltotal operating time heattime (>=0<=279620)minutesfalsesensor.boiler_total_operating_time_heatsensor.boiler_uptimecontrol501/60942
2108Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172uptimecompheatingoperating time compressor heatingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_heatingsensor.boiler_uptimecompheating501/60962
2109Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172uptimecompcoolingoperating time compressor coolingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_coolingsensor.boiler_uptimecompcooling501/60982
2110Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172uptimecompoperating time compressortime (>=0<=279620)minutesfalsesensor.boiler_dhw_operating_time_compressorsensor.boiler_dhw_uptimecomp591/6042
2111Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172uptimecomppooloperating time compressor pooltime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_poolsensor.boiler_uptimecomppool501/601002
2112Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172totalcompstartstotal compressor control startsuint24 (>=0<=16777213)falsesensor.boiler_total_compressor_control_startssensor.boiler_totalcompstarts5011022
2113Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatingstartsheating control startsuint24 (>=0<=16777213)falsesensor.boiler_heating_control_startssensor.boiler_heatingstarts5011042
2114Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172coolingstartscooling control startsuint24 (>=0<=16777213)falsesensor.boiler_cooling_control_startssensor.boiler_coolingstarts5011062
2115Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172starts2control starts2uint24 (>=0<=16777213)falsesensor.boiler_dhw_control_starts2sensor.boiler_dhw_starts259162
2116Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172poolstartspool control startsuint24 (>=0<=16777213)falsesensor.boiler_pool_control_startssensor.boiler_poolstarts5011082
2117Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgconstotaltotal energy consumptionuint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_consumptionsensor.boiler_nrgconstotal5011102
2118Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgconscomptotaltotal energy consumption compressoruint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_consumption_compressorsensor.boiler_nrgconscomptotal5011122
2119Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgconscompheatingenergy consumption compressor heatinguint24 (>=0<=16777213)kWhfalsesensor.boiler_energy_consumption_compressor_heatingsensor.boiler_nrgconscompheating5011142
2120Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgconscompenergy consumption compressoruint24 (>=0<=16777213)kWhfalsesensor.boiler_dhw_energy_consumption_compressorsensor.boiler_dhw_nrgconscomp59182
2121Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgconscompcoolingenergy consumption compressor coolinguint24 (>=0<=16777213)kWhfalsesensor.boiler_energy_consumption_compressor_coolingsensor.boiler_nrgconscompcooling5011162
2122Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgconscomppoolenergy consumption compressor pooluint24 (>=0<=16777213)kWhfalsesensor.boiler_energy_consumption_compressor_poolsensor.boiler_nrgconscomppool5011182
2123Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxelecheatnrgconstotaltotal aux elec. heater energy consumptionuint24 (>=0<=16777213)kWhfalsesensor.boiler_total_aux_elec._heater_energy_consumptionsensor.boiler_auxelecheatnrgconstotal5011202
2124Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxelecheatnrgconsheatingaux elec. heater energy consumption heatinguint24 (>=0<=16777213)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_heatingsensor.boiler_auxelecheatnrgconsheating5011222
2125Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxelecheatnrgconsaux elec. heater energy consumptionuint24 (>=0<=16777213)kWhfalsesensor.boiler_dhw_aux_elec._heater_energy_consumptionsensor.boiler_dhw_auxelecheatnrgcons591102
2126Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxelecheatnrgconspoolaux elec. heater energy consumption pooluint24 (>=0<=16777213)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_poolsensor.boiler_auxelecheatnrgconspool5011242
2127Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgsupptotaltotal energy supplieduint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_suppliedsensor.boiler_nrgsupptotal5011262
2128Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgsuppheatingtotal energy supplied heatinguint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_supplied_heatingsensor.boiler_nrgsuppheating5011282
2129Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgsupptotal energy warm supplieduint24 (>=0<=16777213)kWhfalsesensor.boiler_dhw_total_energy_warm_suppliedsensor.boiler_dhw_nrgsupp591122
2130Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgsuppcoolingtotal energy supplied coolinguint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_supplied_coolingsensor.boiler_nrgsuppcooling5011302
2131Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgsupppooltotal energy supplied pooluint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_supplied_poolsensor.boiler_nrgsupppool5011322
2132Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hppowercompressor power outputuint8 (>=0<=25)kWfalsesensor.boiler_compressor_power_outputsensor.boiler_hppower501/101341
2133Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpmaxpowercompressor max poweruint8 (>=0<=100)%truenumber.boiler_compressor_max_powernumber.boiler_hpmaxpower5011351
2134Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpsetdiffpressset differental pressureuint8 (>=150<=750)mbartruenumber.boiler_set_differental_pressurenumber.boiler_hpsetdiffpress50501361
2135Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpcomponhp compressorbooleanfalsebinary_sensor.boiler_hp_compressorbinary_sensor.boiler_hpcompon5011371
2136Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpactivitycompressor activityenum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost]falsesensor.boiler_compressor_activitysensor.boiler_hpactivity5011381
2137Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpbrinepumpspdbrine pump speeduint8 (>=0<=100)%falsesensor.boiler_brine_pump_speedsensor.boiler_hpbrinepumpspd5011391
2138Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpswitchvalveswitch valvebooleanfalsebinary_sensor.boiler_switch_valvebinary_sensor.boiler_hpswitchvalve5011401
2139Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpcompspdcompressor speeduint8 (>=0<=100)%falsesensor.boiler_compressor_speedsensor.boiler_hpcompspd5011411
2140Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpcircspdcirculation pump speeduint8 (>=0<=100)%falsesensor.boiler_circulation_pump_speedsensor.boiler_hpcircspd5011421
2141Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpbrineinbrine in/evaporatorint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_in/evaporatorsensor.boiler_hpbrinein501/101431
2142Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpbrineoutbrine out/condenserint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_out/condensersensor.boiler_hpbrineout501/101441
2143Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptc0heat carrier return (TC0)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_return_(TC0)sensor.boiler_hptc0501/101451
2144Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptc1heat carrier forward (TC1)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_forward_(TC1)sensor.boiler_hptc1501/101461
2145Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptc3condenser temperature (TC3)int16 (>=-3199<=3199)Cfalsesensor.boiler_condenser_temperature_(TC3)sensor.boiler_hptc3501/101471
2146Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptr1compressor temperature (TR1)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_temperature_(TR1)sensor.boiler_hptr1501/101481
2147Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptr3refrigerant temperature liquid side (condenser output) (TR3)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3)sensor.boiler_hptr3501/101491
2148Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptr4evaporator inlet temperature (TR4)int16 (>=-3199<=3199)Cfalsesensor.boiler_evaporator_inlet_temperature_(TR4)sensor.boiler_hptr4501/101501
2149Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptr5compressor inlet temperature (TR5)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_inlet_temperature_(TR5)sensor.boiler_hptr5501/101511
2150Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptr6compressor outlet temperature (TR6)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_outlet_temperature_(TR6)sensor.boiler_hptr6501/101521
2151Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptr7refrigerant temperature gas side (condenser input) (TR7)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7)sensor.boiler_hptr7501/101531
2152Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptl2air inlet temperature (TL2)int16 (>=-3199<=3199)Cfalsesensor.boiler_air_inlet_temperature_(TL2)sensor.boiler_hptl2501/101541
2153Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hppl1low pressure side temperature (PL1)int16 (>=-3199<=3199)Cfalsesensor.boiler_low_pressure_side_temperature_(PL1)sensor.boiler_hppl1501/101551
2154Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpph1high pressure side temperature (PH1)int16 (>=-3199<=3199)Cfalsesensor.boiler_high_pressure_side_temperature_(PH1)sensor.boiler_hpph1501/101561
2155Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpta4drain pan temp (TA4)int16 (>=-3199<=3199)Cfalsesensor.boiler_drain_pan_temp_(TA4)sensor.boiler_hpta4501/101571
2156Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptw1reservoir temp (TW1)int16 (>=-3199<=3199)Cfalsesensor.boiler_reservoir_temp_(TW1)sensor.boiler_hptw1501/101581
2157Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172poolsettemppool set temperatureuint8 (>=0<=127)Ctruenumber.boiler_pool_set_temperaturenumber.boiler_poolsettemp501/21591
2158Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hp4way4-way valve (VR4)enum [cooling & defrost\|heating & dhw]falsesensor.boiler_4-way_valve_(VR4)sensor.boiler_hp4way5011601
2159Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpin1input 1 statebooleanfalsebinary_sensor.boiler_input_1_statebinary_sensor.boiler_hpin15011611
2160Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpin1optinput 1 optionsstringtruesensor.boiler_input_1_optionssensor.boiler_hpin1opt5011628
2161Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpin2input 2 statebooleanfalsebinary_sensor.boiler_input_2_statebinary_sensor.boiler_hpin25011701
2162Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpin2optinput 2 optionsstringtruesensor.boiler_input_2_optionssensor.boiler_hpin2opt5011718
2163Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpin3input 3 statebooleanfalsebinary_sensor.boiler_input_3_statebinary_sensor.boiler_hpin35011791
2164Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpin3optinput 3 optionsstringtruesensor.boiler_input_3_optionssensor.boiler_hpin3opt5011808
2165Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpin4input 4 statebooleanfalsebinary_sensor.boiler_input_4_statebinary_sensor.boiler_hpin45011881
2166Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpin4optinput 4 optionsstringtruesensor.boiler_input_4_optionssensor.boiler_hpin4opt5011898
2167Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maxheatcompheat limit compressorenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_compressorselect.boiler_maxheatcomp5011971
2168Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maxheatheatheat limit heatingenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_heatingselect.boiler_maxheatheat5011981
2169Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maxheatheat limitenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_dhw_heat_limitselect.boiler_dhw_maxheat591141
2170Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172mandefrostmanual defrostbooleantrueswitch.boiler_manual_defrostswitch.boiler_mandefrost5011991
2171Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172pvcoolingcooling only with PVbooleantrueswitch.boiler_cooling_only_with_PVswitch.boiler_pvcooling5012001
2172Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxheateronlyaux heater onlybooleantrueswitch.boiler_aux_heater_onlyswitch.boiler_auxheateronly5012011
2173Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxheateroffdisable aux heaterbooleantrueswitch.boiler_disable_aux_heaterswitch.boiler_auxheateroff5012021
2174Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxheaterstatusaux heater statusuint8 (>=0<=100)%falsesensor.boiler_aux_heater_statussensor.boiler_auxheaterstatus5012031
2175Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxheaterdelayaux heater on delayuint16 (>=10<=1000)K*mintruenumber.boiler_aux_heater_on_delaynumber.boiler_auxheaterdelay50102041
2176Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxmaxlimitaux heater max limituint8 (>=0<=10)Ktruenumber.boiler_aux_heater_max_limitnumber.boiler_auxmaxlimit501/102051
2177Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxlimitstartaux heater limit startuint8 (>=0<=10)Ktruenumber.boiler_aux_heater_limit_startnumber.boiler_auxlimitstart501/102061
2178Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxheatrmodeaux heater modeenum [eco\|comfort]trueselect.boiler_aux_heater_modeselect.boiler_auxheatrmode5012071
2179Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hphystheaton/off hyst heatuint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_heatnumber.boiler_hphystheat5052081
2180Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hphystcoolon/off hyst cooluint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_coolnumber.boiler_hphystcool5052091
2181Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hphystpoolon/off hyst pooluint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_poolnumber.boiler_hphystpool5052101
2182Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172silentmodesilent modeenum [off\|auto\|on]trueselect.boiler_silent_modeselect.boiler_silentmode5012111
2183Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172silentfromsilent mode fromuint8 (>=0<=3810)minutestruenumber.boiler_silent_mode_fromnumber.boiler_silentfrom50152121
2184Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172silenttosilent mode touint8 (>=0<=3810)minutestruenumber.boiler_silent_mode_tonumber.boiler_silentto50152131
2185Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172mintempsilentmin outside temp for silent modeint8 (>=-126<=126)Ctruenumber.boiler_min_outside_temp_for_silent_modenumber.boiler_mintempsilent5012141
2186Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172tempparmodeoutside temp parallel modeint8 (>=-126<=126)Ctruenumber.boiler_outside_temp_parallel_modenumber.boiler_tempparmode5012151
2187Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxheatmixaux heater mixing valveint8 (>=-100<=100)%falsesensor.boiler_aux_heater_mixing_valvesensor.boiler_auxheatmix5012161
2188Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172tempdiffheattemp diff TC3/TC0 heatuint8 (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_heatnumber.boiler_tempdiffheat501/102171
2189Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172tempdiffcooltemp diff TC3/TC0 cooluint8 (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_coolnumber.boiler_tempdiffcool501/102181
2190Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172vpcoolingvalve/pump coolingbooleantrueswitch.boiler_valve/pump_coolingswitch.boiler_vpcooling5012191
2191Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatcableheating cablebooleantrueswitch.boiler_heating_cableswitch.boiler_heatcable5012201
2192Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172vc0valveVC0 valvebooleantrueswitch.boiler_VC0_valveswitch.boiler_vc0valve5012211
2193Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172primepumpprimary heatpumpbooleantrueswitch.boiler_primary_heatpumpswitch.boiler_primepump5012221
2194Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172primepumpmodprimary heatpump modulationuint8 (>=0<=100)%truenumber.boiler_primary_heatpump_modulationnumber.boiler_primepumpmod5012231
2195Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hp3way3-way valvebooleantrueswitch.boiler_3-way_valveswitch.boiler_hp3way5012241
2196Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172elheatstep1el. heater step 1booleantrueswitch.boiler_el._heater_step_1switch.boiler_elheatstep15012251
2197Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172elheatstep2el. heater step 2booleantrueswitch.boiler_el._heater_step_2switch.boiler_elheatstep25012261
2198Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172elheatstep3el. heater step 3booleantrueswitch.boiler_el._heater_step_3switch.boiler_elheatstep35012271
2199Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpea0condensate reservoir heating (EA0)booleanfalsebinary_sensor.boiler_condensate_reservoir_heating_(EA0)binary_sensor.boiler_hpea05012281
2200Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hppumpmodeprimary heatpump modeenum [auto\|continuous]trueselect.boiler_primary_heatpump_modeselect.boiler_hppumpmode5012291
2201Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172fanfanuint8 (>=20<=100)%truenumber.boiler_fannumber.boiler_fan5012301
2202Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172shutdownshutdowncmd [off\|on]truesensor.boiler_shutdownsensor.boiler_shutdown5012311
2203Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpcurrpowercompressor current poweruint16 (>=0<=31999)Wfalsesensor.boiler_compressor_current_powersensor.boiler_hpcurrpower5012681
2204Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hppowerlimitpower limituint16 (>=0<=31999)Wtruenumber.boiler_power_limitnumber.boiler_hppowerlimit5012691
2205Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow5012701
2206Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow5012711
2207Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on5012721
2208Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate5012731
2209Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172alternatingopalternating operationbooleantrueswitch.boiler_dhw_alternating_operationswitch.boiler_dhw_alternatingop591151
2210Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172altopprioheatprioritise heating during dhwuint8 (>=20<=120)minutestruenumber.boiler_dhw_prioritise_heating_during_dhwnumber.boiler_dhw_altopprioheat591161
2211Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172altopprioprioritise dhw during heatinguint8 (>=30<=120)minutestruenumber.boiler_dhw_prioritise_dhw_during_heatingnumber.boiler_dhw_altopprio591171
2212Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172comfoffcomfort switch offuint8 (>=15<=65)Ctruenumber.boiler_dhw_comfort_switch_offnumber.boiler_dhw_comfoff591181
2213Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172ecooffeco switch offuint8 (>=15<=65)Ctruenumber.boiler_dhw_eco_switch_offnumber.boiler_dhw_ecooff591191
2214Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172ecoplusoffeco+ switch offuint8 (>=48<=63)Ctruenumber.boiler_dhw_eco+_switch_offnumber.boiler_dhw_ecoplusoff591201
2215Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172comfdiffcomfort diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_comfort_diffnumber.boiler_dhw_comfdiff591211
2216Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172ecodiffeco diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_eco_diffnumber.boiler_dhw_ecodiff591221
2217Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172ecoplusdiffeco+ diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_eco+_diffnumber.boiler_dhw_ecoplusdiff591231
2218Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172comfstopcomfort stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_comfort_stop_tempnumber.boiler_dhw_comfstop591241
2219Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172ecostopeco stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_eco_stop_tempnumber.boiler_dhw_ecostop591251
2220Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172ecoplusstopeco+ stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_eco+_stop_tempnumber.boiler_dhw_ecoplusstop591261
2221Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpcircpumpcirculation pump available during dhwbooleantrueswitch.boiler_dhw_circulation_pump_available_during_dhwswitch.boiler_dhw_hpcircpump591271
2222Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
2223Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
2224Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
2225Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
2226Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
2227Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
2228Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
2229Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
2230Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
2231Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
2232Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
2233Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
2234Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
2235Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
2236Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
2237Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
2238Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
2239Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
2240Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
2241Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
2242Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
2243Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
2244Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
2245Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
2246Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
2247Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
2248Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
2249Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
2250Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
2251Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
2252Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
2253Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
2254Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
2255Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
2256Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler1723wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
2257Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
2258Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
2259Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
2260Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
2261Geo 5xxboiler173resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
2262Geo 5xxboiler173heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
2263Geo 5xxboiler173heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
2264Geo 5xxboiler173tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
2265Geo 5xxboiler173selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
2266Geo 5xxboiler173heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
2267Geo 5xxboiler173outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
2268Geo 5xxboiler173curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
2269Geo 5xxboiler173rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
2270Geo 5xxboiler173switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
2271Geo 5xxboiler173syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
2272Geo 5xxboiler173boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
2273Geo 5xxboiler173headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
2274Geo 5xxboiler173heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
2275Geo 5xxboiler173heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
2276Geo 5xxboiler173heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
2277Geo 5xxboiler173pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
2278Geo 5xxboiler173pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
2279Geo 5xxboiler173pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
2280Geo 5xxboiler173pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
2281Geo 5xxboiler173pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
2282Geo 5xxboiler173selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
2283Geo 5xxboiler173curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
2284Geo 5xxboiler173burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
2285Geo 5xxboiler173burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
2286Geo 5xxboiler173burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
2287Geo 5xxboiler173heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
2288Geo 5xxboiler173heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
2289Geo 5xxboiler173ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
2290Geo 5xxboiler173lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
2291Geo 5xxboiler173servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
2292Geo 5xxboiler173servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
2293Geo 5xxboiler173maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
2294Geo 5xxboiler173maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
2295Geo 5xxboiler173maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
2296Geo 5xxboiler173maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
2297Geo 5xxboiler173emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
2298Geo 5xxboiler173emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
2299Geo 5xxboiler173nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
2300Geo 5xxboiler173nrgenergyuint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_energysensor.boiler_dhw_nrg591/10002
2301Geo 5xxboiler173nrgheatenergy heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_heatingsensor.boiler_nrgheat501/100822
2302Geo 5xxboiler173nrgcoolenergy coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_coolingsensor.boiler_nrgcool501/1002642
2303Geo 5xxboiler173metertotalmeter totaluint24 (>=0<=167772)kWhfalsesensor.boiler_meter_totalsensor.boiler_metertotal501/100842
2304Geo 5xxboiler173metercompmeter compressoruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_compressorsensor.boiler_metercomp501/100862
2305Geo 5xxboiler173metereheatmeter e-heateruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_e-heatersensor.boiler_metereheat501/100882
2306Geo 5xxboiler173meterheatmeter heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/100902
2307Geo 5xxboiler173metercoolmeter coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_coolingsensor.boiler_metercool501/1002662
2308Geo 5xxboiler173metermeteruint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/10022
2309Geo 5xxboiler173uptimetotalheatpump total uptimetime (>=0<=279620)minutesfalsesensor.boiler_heatpump_total_uptimesensor.boiler_uptimetotal501/60922
2310Geo 5xxboiler173uptimecontroltotal operating time heattime (>=0<=279620)minutesfalsesensor.boiler_total_operating_time_heatsensor.boiler_uptimecontrol501/60942
2311Geo 5xxboiler173uptimecompheatingoperating time compressor heatingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_heatingsensor.boiler_uptimecompheating501/60962
2312Geo 5xxboiler173uptimecompcoolingoperating time compressor coolingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_coolingsensor.boiler_uptimecompcooling501/60982
2313Geo 5xxboiler173uptimecompoperating time compressortime (>=0<=279620)minutesfalsesensor.boiler_dhw_operating_time_compressorsensor.boiler_dhw_uptimecomp591/6042
2314Geo 5xxboiler173uptimecomppooloperating time compressor pooltime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_poolsensor.boiler_uptimecomppool501/601002
2315Geo 5xxboiler173totalcompstartstotal compressor control startsuint24 (>=0<=16777213)falsesensor.boiler_total_compressor_control_startssensor.boiler_totalcompstarts5011022
2316Geo 5xxboiler173heatingstartsheating control startsuint24 (>=0<=16777213)falsesensor.boiler_heating_control_startssensor.boiler_heatingstarts5011042
2317Geo 5xxboiler173coolingstartscooling control startsuint24 (>=0<=16777213)falsesensor.boiler_cooling_control_startssensor.boiler_coolingstarts5011062
2318Geo 5xxboiler173starts2control starts2uint24 (>=0<=16777213)falsesensor.boiler_dhw_control_starts2sensor.boiler_dhw_starts259162
2319Geo 5xxboiler173poolstartspool control startsuint24 (>=0<=16777213)falsesensor.boiler_pool_control_startssensor.boiler_poolstarts5011082
2320Geo 5xxboiler173nrgconstotaltotal energy consumptionuint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_consumptionsensor.boiler_nrgconstotal5011102
2321Geo 5xxboiler173nrgconscomptotaltotal energy consumption compressoruint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_consumption_compressorsensor.boiler_nrgconscomptotal5011122
2322Geo 5xxboiler173nrgconscompheatingenergy consumption compressor heatinguint24 (>=0<=16777213)kWhfalsesensor.boiler_energy_consumption_compressor_heatingsensor.boiler_nrgconscompheating5011142
2323Geo 5xxboiler173nrgconscompenergy consumption compressoruint24 (>=0<=16777213)kWhfalsesensor.boiler_dhw_energy_consumption_compressorsensor.boiler_dhw_nrgconscomp59182
2324Geo 5xxboiler173nrgconscompcoolingenergy consumption compressor coolinguint24 (>=0<=16777213)kWhfalsesensor.boiler_energy_consumption_compressor_coolingsensor.boiler_nrgconscompcooling5011162
2325Geo 5xxboiler173nrgconscomppoolenergy consumption compressor pooluint24 (>=0<=16777213)kWhfalsesensor.boiler_energy_consumption_compressor_poolsensor.boiler_nrgconscomppool5011182
2326Geo 5xxboiler173auxelecheatnrgconstotaltotal aux elec. heater energy consumptionuint24 (>=0<=16777213)kWhfalsesensor.boiler_total_aux_elec._heater_energy_consumptionsensor.boiler_auxelecheatnrgconstotal5011202
2327Geo 5xxboiler173auxelecheatnrgconsheatingaux elec. heater energy consumption heatinguint24 (>=0<=16777213)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_heatingsensor.boiler_auxelecheatnrgconsheating5011222
2328Geo 5xxboiler173auxelecheatnrgconsaux elec. heater energy consumptionuint24 (>=0<=16777213)kWhfalsesensor.boiler_dhw_aux_elec._heater_energy_consumptionsensor.boiler_dhw_auxelecheatnrgcons591102
2329Geo 5xxboiler173auxelecheatnrgconspoolaux elec. heater energy consumption pooluint24 (>=0<=16777213)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_poolsensor.boiler_auxelecheatnrgconspool5011242
2330Geo 5xxboiler173nrgsupptotaltotal energy supplieduint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_suppliedsensor.boiler_nrgsupptotal5011262
2331Geo 5xxboiler173nrgsuppheatingtotal energy supplied heatinguint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_supplied_heatingsensor.boiler_nrgsuppheating5011282
2332Geo 5xxboiler173nrgsupptotal energy warm supplieduint24 (>=0<=16777213)kWhfalsesensor.boiler_dhw_total_energy_warm_suppliedsensor.boiler_dhw_nrgsupp591122
2333Geo 5xxboiler173nrgsuppcoolingtotal energy supplied coolinguint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_supplied_coolingsensor.boiler_nrgsuppcooling5011302
2334Geo 5xxboiler173nrgsupppooltotal energy supplied pooluint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_supplied_poolsensor.boiler_nrgsupppool5011322
2335Geo 5xxboiler173hppowercompressor power outputuint8 (>=0<=25)kWfalsesensor.boiler_compressor_power_outputsensor.boiler_hppower501/101341
2336Geo 5xxboiler173hpmaxpowercompressor max poweruint8 (>=0<=100)%truenumber.boiler_compressor_max_powernumber.boiler_hpmaxpower5011351
2337Geo 5xxboiler173hpsetdiffpressset differental pressureuint8 (>=150<=750)mbartruenumber.boiler_set_differental_pressurenumber.boiler_hpsetdiffpress50501361
2338Geo 5xxboiler173hpcomponhp compressorbooleanfalsebinary_sensor.boiler_hp_compressorbinary_sensor.boiler_hpcompon5011371
2339Geo 5xxboiler173hpactivitycompressor activityenum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost]falsesensor.boiler_compressor_activitysensor.boiler_hpactivity5011381
2340Geo 5xxboiler173hpbrinepumpspdbrine pump speeduint8 (>=0<=100)%falsesensor.boiler_brine_pump_speedsensor.boiler_hpbrinepumpspd5011391
2341Geo 5xxboiler173hpswitchvalveswitch valvebooleanfalsebinary_sensor.boiler_switch_valvebinary_sensor.boiler_hpswitchvalve5011401
2342Geo 5xxboiler173hpcompspdcompressor speeduint8 (>=0<=100)%falsesensor.boiler_compressor_speedsensor.boiler_hpcompspd5011411
2343Geo 5xxboiler173hpcircspdcirculation pump speeduint8 (>=0<=100)%falsesensor.boiler_circulation_pump_speedsensor.boiler_hpcircspd5011421
2344Geo 5xxboiler173hpbrineinbrine in/evaporatorint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_in/evaporatorsensor.boiler_hpbrinein501/101431
2345Geo 5xxboiler173hpbrineoutbrine out/condenserint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_out/condensersensor.boiler_hpbrineout501/101441
2346Geo 5xxboiler173hptc0heat carrier return (TC0)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_return_(TC0)sensor.boiler_hptc0501/101451
2347Geo 5xxboiler173hptc1heat carrier forward (TC1)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_forward_(TC1)sensor.boiler_hptc1501/101461
2348Geo 5xxboiler173hptc3condenser temperature (TC3)int16 (>=-3199<=3199)Cfalsesensor.boiler_condenser_temperature_(TC3)sensor.boiler_hptc3501/101471
2349Geo 5xxboiler173hptr1compressor temperature (TR1)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_temperature_(TR1)sensor.boiler_hptr1501/101481
2350Geo 5xxboiler173hptr3refrigerant temperature liquid side (condenser output) (TR3)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3)sensor.boiler_hptr3501/101491
2351Geo 5xxboiler173hptr4evaporator inlet temperature (TR4)int16 (>=-3199<=3199)Cfalsesensor.boiler_evaporator_inlet_temperature_(TR4)sensor.boiler_hptr4501/101501
2352Geo 5xxboiler173hptr5compressor inlet temperature (TR5)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_inlet_temperature_(TR5)sensor.boiler_hptr5501/101511
2353Geo 5xxboiler173hptr6compressor outlet temperature (TR6)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_outlet_temperature_(TR6)sensor.boiler_hptr6501/101521
2354Geo 5xxboiler173hptr7refrigerant temperature gas side (condenser input) (TR7)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7)sensor.boiler_hptr7501/101531
2355Geo 5xxboiler173hptl2air inlet temperature (TL2)int16 (>=-3199<=3199)Cfalsesensor.boiler_air_inlet_temperature_(TL2)sensor.boiler_hptl2501/101541
2356Geo 5xxboiler173hppl1low pressure side temperature (PL1)int16 (>=-3199<=3199)Cfalsesensor.boiler_low_pressure_side_temperature_(PL1)sensor.boiler_hppl1501/101551
2357Geo 5xxboiler173hpph1high pressure side temperature (PH1)int16 (>=-3199<=3199)Cfalsesensor.boiler_high_pressure_side_temperature_(PH1)sensor.boiler_hpph1501/101561
2358Geo 5xxboiler173hpta4drain pan temp (TA4)int16 (>=-3199<=3199)Cfalsesensor.boiler_drain_pan_temp_(TA4)sensor.boiler_hpta4501/101571
2359Geo 5xxboiler173hptw1reservoir temp (TW1)int16 (>=-3199<=3199)Cfalsesensor.boiler_reservoir_temp_(TW1)sensor.boiler_hptw1501/101581
2360Geo 5xxboiler173poolsettemppool set temperatureuint8 (>=0<=127)Ctruenumber.boiler_pool_set_temperaturenumber.boiler_poolsettemp501/21591
2361Geo 5xxboiler173hp4way4-way valve (VR4)enum [cooling & defrost\|heating & dhw]falsesensor.boiler_4-way_valve_(VR4)sensor.boiler_hp4way5011601
2362Geo 5xxboiler173hpin1input 1 statebooleanfalsebinary_sensor.boiler_input_1_statebinary_sensor.boiler_hpin15011611
2363Geo 5xxboiler173hpin1optinput 1 optionsstringtruesensor.boiler_input_1_optionssensor.boiler_hpin1opt5011628
2364Geo 5xxboiler173hpin2input 2 statebooleanfalsebinary_sensor.boiler_input_2_statebinary_sensor.boiler_hpin25011701
2365Geo 5xxboiler173hpin2optinput 2 optionsstringtruesensor.boiler_input_2_optionssensor.boiler_hpin2opt5011718
2366Geo 5xxboiler173hpin3input 3 statebooleanfalsebinary_sensor.boiler_input_3_statebinary_sensor.boiler_hpin35011791
2367Geo 5xxboiler173hpin3optinput 3 optionsstringtruesensor.boiler_input_3_optionssensor.boiler_hpin3opt5011808
2368Geo 5xxboiler173hpin4input 4 statebooleanfalsebinary_sensor.boiler_input_4_statebinary_sensor.boiler_hpin45011881
2369Geo 5xxboiler173hpin4optinput 4 optionsstringtruesensor.boiler_input_4_optionssensor.boiler_hpin4opt5011898
2370Geo 5xxboiler173maxheatcompheat limit compressorenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_compressorselect.boiler_maxheatcomp5011971
2371Geo 5xxboiler173maxheatheatheat limit heatingenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_heatingselect.boiler_maxheatheat5011981
2372Geo 5xxboiler173maxheatheat limitenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_dhw_heat_limitselect.boiler_dhw_maxheat591141
2373Geo 5xxboiler173mandefrostmanual defrostbooleantrueswitch.boiler_manual_defrostswitch.boiler_mandefrost5011991
2374Geo 5xxboiler173pvcoolingcooling only with PVbooleantrueswitch.boiler_cooling_only_with_PVswitch.boiler_pvcooling5012001
2375Geo 5xxboiler173auxheateronlyaux heater onlybooleantrueswitch.boiler_aux_heater_onlyswitch.boiler_auxheateronly5012011
2376Geo 5xxboiler173auxheateroffdisable aux heaterbooleantrueswitch.boiler_disable_aux_heaterswitch.boiler_auxheateroff5012021
2377Geo 5xxboiler173auxheaterstatusaux heater statusuint8 (>=0<=100)%falsesensor.boiler_aux_heater_statussensor.boiler_auxheaterstatus5012031
2378Geo 5xxboiler173auxheaterdelayaux heater on delayuint16 (>=10<=1000)K*mintruenumber.boiler_aux_heater_on_delaynumber.boiler_auxheaterdelay50102041
2379Geo 5xxboiler173auxmaxlimitaux heater max limituint8 (>=0<=10)Ktruenumber.boiler_aux_heater_max_limitnumber.boiler_auxmaxlimit501/102051
2380Geo 5xxboiler173auxlimitstartaux heater limit startuint8 (>=0<=10)Ktruenumber.boiler_aux_heater_limit_startnumber.boiler_auxlimitstart501/102061
2381Geo 5xxboiler173auxheatrmodeaux heater modeenum [eco\|comfort]trueselect.boiler_aux_heater_modeselect.boiler_auxheatrmode5012071
2382Geo 5xxboiler173hphystheaton/off hyst heatuint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_heatnumber.boiler_hphystheat5052081
2383Geo 5xxboiler173hphystcoolon/off hyst cooluint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_coolnumber.boiler_hphystcool5052091
2384Geo 5xxboiler173hphystpoolon/off hyst pooluint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_poolnumber.boiler_hphystpool5052101
2385Geo 5xxboiler173silentmodesilent modeenum [off\|auto\|on]trueselect.boiler_silent_modeselect.boiler_silentmode5012111
2386Geo 5xxboiler173silentfromsilent mode fromuint8 (>=0<=3810)minutestruenumber.boiler_silent_mode_fromnumber.boiler_silentfrom50152121
2387Geo 5xxboiler173silenttosilent mode touint8 (>=0<=3810)minutestruenumber.boiler_silent_mode_tonumber.boiler_silentto50152131
2388Geo 5xxboiler173mintempsilentmin outside temp for silent modeint8 (>=-126<=126)Ctruenumber.boiler_min_outside_temp_for_silent_modenumber.boiler_mintempsilent5012141
2389Geo 5xxboiler173tempparmodeoutside temp parallel modeint8 (>=-126<=126)Ctruenumber.boiler_outside_temp_parallel_modenumber.boiler_tempparmode5012151
2390Geo 5xxboiler173auxheatmixaux heater mixing valveint8 (>=-100<=100)%falsesensor.boiler_aux_heater_mixing_valvesensor.boiler_auxheatmix5012161
2391Geo 5xxboiler173tempdiffheattemp diff TC3/TC0 heatuint8 (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_heatnumber.boiler_tempdiffheat501/102171
2392Geo 5xxboiler173tempdiffcooltemp diff TC3/TC0 cooluint8 (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_coolnumber.boiler_tempdiffcool501/102181
2393Geo 5xxboiler173vpcoolingvalve/pump coolingbooleantrueswitch.boiler_valve/pump_coolingswitch.boiler_vpcooling5012191
2394Geo 5xxboiler173heatcableheating cablebooleantrueswitch.boiler_heating_cableswitch.boiler_heatcable5012201
2395Geo 5xxboiler173vc0valveVC0 valvebooleantrueswitch.boiler_VC0_valveswitch.boiler_vc0valve5012211
2396Geo 5xxboiler173primepumpprimary heatpumpbooleantrueswitch.boiler_primary_heatpumpswitch.boiler_primepump5012221
2397Geo 5xxboiler173primepumpmodprimary heatpump modulationuint8 (>=0<=100)%truenumber.boiler_primary_heatpump_modulationnumber.boiler_primepumpmod5012231
2398Geo 5xxboiler173hp3way3-way valvebooleantrueswitch.boiler_3-way_valveswitch.boiler_hp3way5012241
2399Geo 5xxboiler173elheatstep1el. heater step 1booleantrueswitch.boiler_el._heater_step_1switch.boiler_elheatstep15012251
2400Geo 5xxboiler173elheatstep2el. heater step 2booleantrueswitch.boiler_el._heater_step_2switch.boiler_elheatstep25012261
2401Geo 5xxboiler173elheatstep3el. heater step 3booleantrueswitch.boiler_el._heater_step_3switch.boiler_elheatstep35012271
2402Geo 5xxboiler173hpea0condensate reservoir heating (EA0)booleanfalsebinary_sensor.boiler_condensate_reservoir_heating_(EA0)binary_sensor.boiler_hpea05012281
2403Geo 5xxboiler173hppumpmodeprimary heatpump modeenum [auto\|continuous]trueselect.boiler_primary_heatpump_modeselect.boiler_hppumpmode5012291
2404Geo 5xxboiler173fanfanuint8 (>=20<=100)%truenumber.boiler_fannumber.boiler_fan5012301
2405Geo 5xxboiler173shutdownshutdowncmd [off\|on]truesensor.boiler_shutdownsensor.boiler_shutdown5012311
2406Geo 5xxboiler173hpcurrpowercompressor current poweruint16 (>=0<=31999)Wfalsesensor.boiler_compressor_current_powersensor.boiler_hpcurrpower5012681
2407Geo 5xxboiler173hppowerlimitpower limituint16 (>=0<=31999)Wtruenumber.boiler_power_limitnumber.boiler_hppowerlimit5012691
2408Geo 5xxboiler173pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow5012701
2409Geo 5xxboiler173pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow5012711
2410Geo 5xxboiler173pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on5012721
2411Geo 5xxboiler173pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate5012731
2412Geo 5xxboiler173alternatingopalternating operationbooleantrueswitch.boiler_dhw_alternating_operationswitch.boiler_dhw_alternatingop591151
2413Geo 5xxboiler173altopprioheatprioritise heating during dhwuint8 (>=20<=120)minutestruenumber.boiler_dhw_prioritise_heating_during_dhwnumber.boiler_dhw_altopprioheat591161
2414Geo 5xxboiler173altopprioprioritise dhw during heatinguint8 (>=30<=120)minutestruenumber.boiler_dhw_prioritise_dhw_during_heatingnumber.boiler_dhw_altopprio591171
2415Geo 5xxboiler173comfoffcomfort switch offuint8 (>=15<=65)Ctruenumber.boiler_dhw_comfort_switch_offnumber.boiler_dhw_comfoff591181
2416Geo 5xxboiler173ecooffeco switch offuint8 (>=15<=65)Ctruenumber.boiler_dhw_eco_switch_offnumber.boiler_dhw_ecooff591191
2417Geo 5xxboiler173ecoplusoffeco+ switch offuint8 (>=48<=63)Ctruenumber.boiler_dhw_eco+_switch_offnumber.boiler_dhw_ecoplusoff591201
2418Geo 5xxboiler173comfdiffcomfort diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_comfort_diffnumber.boiler_dhw_comfdiff591211
2419Geo 5xxboiler173ecodiffeco diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_eco_diffnumber.boiler_dhw_ecodiff591221
2420Geo 5xxboiler173ecoplusdiffeco+ diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_eco+_diffnumber.boiler_dhw_ecoplusdiff591231
2421Geo 5xxboiler173comfstopcomfort stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_comfort_stop_tempnumber.boiler_dhw_comfstop591241
2422Geo 5xxboiler173ecostopeco stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_eco_stop_tempnumber.boiler_dhw_ecostop591251
2423Geo 5xxboiler173ecoplusstopeco+ stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_eco+_stop_tempnumber.boiler_dhw_ecoplusstop591261
2424Geo 5xxboiler173hpcircpumpcirculation pump available during dhwbooleantrueswitch.boiler_dhw_circulation_pump_available_during_dhwswitch.boiler_dhw_hpcircpump591271
2425Geo 5xxboiler173tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
2426Geo 5xxboiler173settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
2427Geo 5xxboiler173seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
2428Geo 5xxboiler173seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
2429Geo 5xxboiler173tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
2430Geo 5xxboiler173seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
2431Geo 5xxboiler173seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
2432Geo 5xxboiler173solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
2433Geo 5xxboiler173typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
2434Geo 5xxboiler173comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
2435Geo 5xxboiler173comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
2436Geo 5xxboiler173flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
2437Geo 5xxboiler173chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
2438Geo 5xxboiler173maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
2439Geo 5xxboiler173maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
2440Geo 5xxboiler173circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
2441Geo 5xxboiler173chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
2442Geo 5xxboiler173hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
2443Geo 5xxboiler173hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
2444Geo 5xxboiler173disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
2445Geo 5xxboiler173circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
2446Geo 5xxboiler173circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
2447Geo 5xxboiler173curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
2448Geo 5xxboiler173curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
2449Geo 5xxboiler173curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
2450Geo 5xxboiler173storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
2451Geo 5xxboiler173storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
2452Geo 5xxboiler173activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
2453Geo 5xxboiler173onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
2454Geo 5xxboiler173disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
2455Geo 5xxboiler173chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
2456Geo 5xxboiler173rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
2457Geo 5xxboiler173tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
2458Geo 5xxboiler173activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
2459Geo 5xxboiler1733wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
2460Geo 5xxboiler173mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
2461Geo 5xxboiler173cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
2462Geo 5xxboiler173startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
2463Geo 5xxboiler173workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
2464Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
2465Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
2466Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
2467Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
2468Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
2469Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
2470Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
2471Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
2472Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
2473Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
2474Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
2475Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
2476Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
2477Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
2478Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
2479Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
2480Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
2481Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
2482Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
2483Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
2484Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
2485Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
2486Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
2487Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
2488Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
2489Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
2490Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
2491Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
2492Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
2493Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
2494Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
2495Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
2496Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
2497Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
2498Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
2499Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
2500Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141