| 1 | device name | device type | product id | shortname | fullname | type [options...] \| (min/max) | uom | writeable | discovery entityid v3.4 | discovery entityid |
|---|---|---|---|---|---|---|---|---|---|---|
| 2 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 3 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 4 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 5 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 6 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 7 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 8 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 9 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 10 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 11 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 12 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 13 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 14 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 15 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 16 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 17 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 18 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 19 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 20 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 21 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 22 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 23 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 24 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 25 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 26 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 27 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 28 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 29 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 30 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 31 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 32 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 33 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 34 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 35 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 36 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 37 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 38 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 39 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 40 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 41 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 42 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 43 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 44 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 45 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 46 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 47 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 48 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 49 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 50 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 51 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 52 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 53 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 54 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 55 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 56 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 57 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 58 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 59 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 60 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 61 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 62 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 63 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 64 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 65 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 66 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 67 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 68 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 69 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 70 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 71 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 72 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 73 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 74 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 75 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 76 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 77 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 78 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 79 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 80 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 81 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 82 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 83 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 84 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 85 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 86 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 87 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 88 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 89 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 90 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 91 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 92 | BK13/BK15/Smartline/GB1x2 | boiler | 64 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 93 | GB125/GB135/MC10 | boiler | 72 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 94 | GB125/GB135/MC10 | boiler | 72 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 95 | GB125/GB135/MC10 | boiler | 72 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 96 | GB125/GB135/MC10 | boiler | 72 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 97 | GB125/GB135/MC10 | boiler | 72 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 98 | GB125/GB135/MC10 | boiler | 72 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 99 | GB125/GB135/MC10 | boiler | 72 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 100 | GB125/GB135/MC10 | boiler | 72 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 101 | GB125/GB135/MC10 | boiler | 72 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 102 | GB125/GB135/MC10 | boiler | 72 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 103 | GB125/GB135/MC10 | boiler | 72 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 104 | GB125/GB135/MC10 | boiler | 72 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 105 | GB125/GB135/MC10 | boiler | 72 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 106 | GB125/GB135/MC10 | boiler | 72 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 107 | GB125/GB135/MC10 | boiler | 72 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 108 | GB125/GB135/MC10 | boiler | 72 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 109 | GB125/GB135/MC10 | boiler | 72 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 110 | GB125/GB135/MC10 | boiler | 72 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 111 | GB125/GB135/MC10 | boiler | 72 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 112 | GB125/GB135/MC10 | boiler | 72 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 113 | GB125/GB135/MC10 | boiler | 72 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 114 | GB125/GB135/MC10 | boiler | 72 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 115 | GB125/GB135/MC10 | boiler | 72 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 116 | GB125/GB135/MC10 | boiler | 72 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 117 | GB125/GB135/MC10 | boiler | 72 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 118 | GB125/GB135/MC10 | boiler | 72 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 119 | GB125/GB135/MC10 | boiler | 72 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 120 | GB125/GB135/MC10 | boiler | 72 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 121 | GB125/GB135/MC10 | boiler | 72 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 122 | GB125/GB135/MC10 | boiler | 72 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 123 | GB125/GB135/MC10 | boiler | 72 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 124 | GB125/GB135/MC10 | boiler | 72 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 125 | GB125/GB135/MC10 | boiler | 72 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 126 | GB125/GB135/MC10 | boiler | 72 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 127 | GB125/GB135/MC10 | boiler | 72 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 128 | GB125/GB135/MC10 | boiler | 72 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 129 | GB125/GB135/MC10 | boiler | 72 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 130 | GB125/GB135/MC10 | boiler | 72 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 131 | GB125/GB135/MC10 | boiler | 72 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 132 | GB125/GB135/MC10 | boiler | 72 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 133 | GB125/GB135/MC10 | boiler | 72 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 134 | GB125/GB135/MC10 | boiler | 72 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 135 | GB125/GB135/MC10 | boiler | 72 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 136 | GB125/GB135/MC10 | boiler | 72 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 137 | GB125/GB135/MC10 | boiler | 72 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 138 | GB125/GB135/MC10 | boiler | 72 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 139 | GB125/GB135/MC10 | boiler | 72 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 140 | GB125/GB135/MC10 | boiler | 72 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 141 | GB125/GB135/MC10 | boiler | 72 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 142 | GB125/GB135/MC10 | boiler | 72 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 143 | GB125/GB135/MC10 | boiler | 72 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 144 | GB125/GB135/MC10 | boiler | 72 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 145 | GB125/GB135/MC10 | boiler | 72 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 146 | GB125/GB135/MC10 | boiler | 72 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 147 | GB125/GB135/MC10 | boiler | 72 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 148 | GB125/GB135/MC10 | boiler | 72 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 149 | GB125/GB135/MC10 | boiler | 72 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 150 | GB125/GB135/MC10 | boiler | 72 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 151 | GB125/GB135/MC10 | boiler | 72 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 152 | GB125/GB135/MC10 | boiler | 72 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 153 | GB125/GB135/MC10 | boiler | 72 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 154 | GB125/GB135/MC10 | boiler | 72 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 155 | GB125/GB135/MC10 | boiler | 72 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 156 | GB125/GB135/MC10 | boiler | 72 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 157 | GB125/GB135/MC10 | boiler | 72 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 158 | GB125/GB135/MC10 | boiler | 72 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 159 | GB125/GB135/MC10 | boiler | 72 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 160 | GB125/GB135/MC10 | boiler | 72 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 161 | GB125/GB135/MC10 | boiler | 72 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 162 | GB125/GB135/MC10 | boiler | 72 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 163 | GB125/GB135/MC10 | boiler | 72 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 164 | GB125/GB135/MC10 | boiler | 72 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 165 | GB125/GB135/MC10 | boiler | 72 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 166 | GB125/GB135/MC10 | boiler | 72 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 167 | GB125/GB135/MC10 | boiler | 72 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 168 | GB125/GB135/MC10 | boiler | 72 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 169 | GB125/GB135/MC10 | boiler | 72 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 170 | GB125/GB135/MC10 | boiler | 72 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 171 | GB125/GB135/MC10 | boiler | 72 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 172 | GB125/GB135/MC10 | boiler | 72 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 173 | GB125/GB135/MC10 | boiler | 72 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 174 | GB125/GB135/MC10 | boiler | 72 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 175 | GB125/GB135/MC10 | boiler | 72 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 176 | GB125/GB135/MC10 | boiler | 72 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 177 | GB125/GB135/MC10 | boiler | 72 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 178 | GB125/GB135/MC10 | boiler | 72 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 179 | GB125/GB135/MC10 | boiler | 72 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 180 | GB125/GB135/MC10 | boiler | 72 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 181 | GB125/GB135/MC10 | boiler | 72 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 182 | GB125/GB135/MC10 | boiler | 72 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 183 | GB125/GB135/MC10 | boiler | 72 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 184 | Cascade CM10 | boiler | 81 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 185 | Cascade CM10 | boiler | 81 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 186 | Cascade CM10 | boiler | 81 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 187 | Cascade CM10 | boiler | 81 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 188 | Cascade CM10 | boiler | 81 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 189 | Cascade CM10 | boiler | 81 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 190 | Cascade CM10 | boiler | 81 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 191 | Cascade CM10 | boiler | 81 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 192 | Cascade CM10 | boiler | 81 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 193 | Cascade CM10 | boiler | 81 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 194 | Cascade CM10 | boiler | 81 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 195 | Cascade CM10 | boiler | 81 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 196 | Cascade CM10 | boiler | 81 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 197 | Cascade CM10 | boiler | 81 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 198 | Cascade CM10 | boiler | 81 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 199 | Cascade CM10 | boiler | 81 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 200 | Cascade CM10 | boiler | 81 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 201 | Cascade CM10 | boiler | 81 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 202 | Cascade CM10 | boiler | 81 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 203 | Cascade CM10 | boiler | 81 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 204 | Cascade CM10 | boiler | 81 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 205 | Cascade CM10 | boiler | 81 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 206 | Cascade CM10 | boiler | 81 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 207 | Cascade CM10 | boiler | 81 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 208 | Cascade CM10 | boiler | 81 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 209 | Cascade CM10 | boiler | 81 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 210 | Cascade CM10 | boiler | 81 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 211 | Cascade CM10 | boiler | 81 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 212 | Cascade CM10 | boiler | 81 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 213 | Cascade CM10 | boiler | 81 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 214 | Cascade CM10 | boiler | 81 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 215 | Cascade CM10 | boiler | 81 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 216 | Cascade CM10 | boiler | 81 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 217 | Cascade CM10 | boiler | 81 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 218 | Cascade CM10 | boiler | 81 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 219 | Cascade CM10 | boiler | 81 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 220 | Cascade CM10 | boiler | 81 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 221 | Cascade CM10 | boiler | 81 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 222 | Cascade CM10 | boiler | 81 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 223 | Cascade CM10 | boiler | 81 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 224 | Cascade CM10 | boiler | 81 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 225 | Cascade CM10 | boiler | 81 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 226 | Cascade CM10 | boiler | 81 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 227 | Cascade CM10 | boiler | 81 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 228 | Cascade CM10 | boiler | 81 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 229 | Cascade CM10 | boiler | 81 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 230 | Cascade CM10 | boiler | 81 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 231 | Cascade CM10 | boiler | 81 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 232 | Cascade CM10 | boiler | 81 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 233 | Cascade CM10 | boiler | 81 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 234 | Cascade CM10 | boiler | 81 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 235 | Cascade CM10 | boiler | 81 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 236 | Cascade CM10 | boiler | 81 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 237 | Cascade CM10 | boiler | 81 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 238 | Cascade CM10 | boiler | 81 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 239 | Cascade CM10 | boiler | 81 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 240 | Cascade CM10 | boiler | 81 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 241 | Cascade CM10 | boiler | 81 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 242 | Cascade CM10 | boiler | 81 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 243 | Cascade CM10 | boiler | 81 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 244 | Cascade CM10 | boiler | 81 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 245 | Cascade CM10 | boiler | 81 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 246 | Cascade CM10 | boiler | 81 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 247 | Cascade CM10 | boiler | 81 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 248 | Cascade CM10 | boiler | 81 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 249 | Cascade CM10 | boiler | 81 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 250 | Cascade CM10 | boiler | 81 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 251 | Cascade CM10 | boiler | 81 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 252 | Cascade CM10 | boiler | 81 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 253 | Cascade CM10 | boiler | 81 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 254 | Cascade CM10 | boiler | 81 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 255 | Cascade CM10 | boiler | 81 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 256 | Cascade CM10 | boiler | 81 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 257 | Cascade CM10 | boiler | 81 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 258 | Cascade CM10 | boiler | 81 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 259 | Cascade CM10 | boiler | 81 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 260 | Cascade CM10 | boiler | 81 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 261 | Cascade CM10 | boiler | 81 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 262 | Cascade CM10 | boiler | 81 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 263 | Cascade CM10 | boiler | 81 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 264 | Cascade CM10 | boiler | 81 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 265 | Cascade CM10 | boiler | 81 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 266 | Cascade CM10 | boiler | 81 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 267 | Cascade CM10 | boiler | 81 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 268 | Cascade CM10 | boiler | 81 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 269 | Cascade CM10 | boiler | 81 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 270 | Cascade CM10 | boiler | 81 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 271 | Cascade CM10 | boiler | 81 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 272 | Cascade CM10 | boiler | 81 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 273 | Cascade CM10 | boiler | 81 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 274 | Cascade CM10 | boiler | 81 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 275 | Logamax Plus GB022 | boiler | 84 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 276 | Logamax Plus GB022 | boiler | 84 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 277 | Logamax Plus GB022 | boiler | 84 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 278 | Logamax Plus GB022 | boiler | 84 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 279 | Logamax Plus GB022 | boiler | 84 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 280 | Logamax Plus GB022 | boiler | 84 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 281 | Logamax Plus GB022 | boiler | 84 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 282 | Logamax Plus GB022 | boiler | 84 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 283 | Logamax Plus GB022 | boiler | 84 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 284 | Logamax Plus GB022 | boiler | 84 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 285 | Logamax Plus GB022 | boiler | 84 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 286 | Logamax Plus GB022 | boiler | 84 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 287 | Logamax Plus GB022 | boiler | 84 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 288 | Logamax Plus GB022 | boiler | 84 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 289 | Logamax Plus GB022 | boiler | 84 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 290 | Logamax Plus GB022 | boiler | 84 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 291 | Logamax Plus GB022 | boiler | 84 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 292 | Logamax Plus GB022 | boiler | 84 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 293 | Logamax Plus GB022 | boiler | 84 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 294 | Logamax Plus GB022 | boiler | 84 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 295 | Logamax Plus GB022 | boiler | 84 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 296 | Logamax Plus GB022 | boiler | 84 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 297 | Logamax Plus GB022 | boiler | 84 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 298 | Logamax Plus GB022 | boiler | 84 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 299 | Logamax Plus GB022 | boiler | 84 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 300 | Logamax Plus GB022 | boiler | 84 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 301 | Logamax Plus GB022 | boiler | 84 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 302 | Logamax Plus GB022 | boiler | 84 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 303 | Logamax Plus GB022 | boiler | 84 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 304 | Logamax Plus GB022 | boiler | 84 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 305 | Logamax Plus GB022 | boiler | 84 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 306 | Logamax Plus GB022 | boiler | 84 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 307 | Logamax Plus GB022 | boiler | 84 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 308 | Logamax Plus GB022 | boiler | 84 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 309 | Logamax Plus GB022 | boiler | 84 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 310 | Logamax Plus GB022 | boiler | 84 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 311 | Logamax Plus GB022 | boiler | 84 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 312 | Logamax Plus GB022 | boiler | 84 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 313 | Logamax Plus GB022 | boiler | 84 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 314 | Logamax Plus GB022 | boiler | 84 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 315 | Logamax Plus GB022 | boiler | 84 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 316 | Logamax Plus GB022 | boiler | 84 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 317 | Logamax Plus GB022 | boiler | 84 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 318 | Logamax Plus GB022 | boiler | 84 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 319 | Logamax Plus GB022 | boiler | 84 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 320 | Logamax Plus GB022 | boiler | 84 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 321 | Logamax Plus GB022 | boiler | 84 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 322 | Logamax Plus GB022 | boiler | 84 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 323 | Logamax Plus GB022 | boiler | 84 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 324 | Logamax Plus GB022 | boiler | 84 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 325 | Logamax Plus GB022 | boiler | 84 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 326 | Logamax Plus GB022 | boiler | 84 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 327 | Logamax Plus GB022 | boiler | 84 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 328 | Logamax Plus GB022 | boiler | 84 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 329 | Logamax Plus GB022 | boiler | 84 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 330 | Logamax Plus GB022 | boiler | 84 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 331 | Logamax Plus GB022 | boiler | 84 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 332 | Logamax Plus GB022 | boiler | 84 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 333 | Logamax Plus GB022 | boiler | 84 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 334 | Logamax Plus GB022 | boiler | 84 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 335 | Logamax Plus GB022 | boiler | 84 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 336 | Logamax Plus GB022 | boiler | 84 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 337 | Logamax Plus GB022 | boiler | 84 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 338 | Logamax Plus GB022 | boiler | 84 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 339 | Logamax Plus GB022 | boiler | 84 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 340 | Logamax Plus GB022 | boiler | 84 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 341 | Logamax Plus GB022 | boiler | 84 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 342 | Logamax Plus GB022 | boiler | 84 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 343 | Logamax Plus GB022 | boiler | 84 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 344 | Logamax Plus GB022 | boiler | 84 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 345 | Logamax Plus GB022 | boiler | 84 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 346 | Logamax Plus GB022 | boiler | 84 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 347 | Logamax Plus GB022 | boiler | 84 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 348 | Logamax Plus GB022 | boiler | 84 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 349 | Logamax Plus GB022 | boiler | 84 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 350 | Logamax Plus GB022 | boiler | 84 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 351 | Logamax Plus GB022 | boiler | 84 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 352 | Logamax Plus GB022 | boiler | 84 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 353 | Logamax Plus GB022 | boiler | 84 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 354 | Logamax Plus GB022 | boiler | 84 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 355 | Logamax Plus GB022 | boiler | 84 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 356 | Logamax Plus GB022 | boiler | 84 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 357 | Logamax Plus GB022 | boiler | 84 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 358 | Logamax Plus GB022 | boiler | 84 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 359 | Logamax Plus GB022 | boiler | 84 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 360 | Logamax Plus GB022 | boiler | 84 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 361 | Logamax Plus GB022 | boiler | 84 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 362 | Logamax Plus GB022 | boiler | 84 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 363 | Logamax Plus GB022 | boiler | 84 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 364 | Logamax Plus GB022 | boiler | 84 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 365 | Logamax Plus GB022 | boiler | 84 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 366 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 367 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 368 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 369 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 370 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 371 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 372 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 373 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 374 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 375 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 376 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 377 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 378 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 379 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 380 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 381 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 382 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 383 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 384 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 385 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 386 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 387 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 388 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 389 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 390 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 391 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 392 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 393 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 394 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 395 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 396 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 397 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 398 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 399 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 400 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 401 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 402 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 403 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 404 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 405 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 406 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 407 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 408 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 409 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 410 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 411 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 412 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 413 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 414 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 415 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 416 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 417 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 418 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 419 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 420 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 421 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 422 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 423 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 424 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 425 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 426 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 427 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 428 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 429 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 430 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 431 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 432 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 433 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 434 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 435 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 436 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 437 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 438 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 439 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 440 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 441 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 442 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 443 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 444 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 445 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 446 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 447 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 448 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 449 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 450 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 451 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 452 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 453 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 454 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 455 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 456 | Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3 | boiler | 95 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 457 | Topline/GB162 | boiler | 115 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 458 | Topline/GB162 | boiler | 115 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 459 | Topline/GB162 | boiler | 115 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 460 | Topline/GB162 | boiler | 115 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 461 | Topline/GB162 | boiler | 115 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 462 | Topline/GB162 | boiler | 115 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 463 | Topline/GB162 | boiler | 115 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 464 | Topline/GB162 | boiler | 115 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 465 | Topline/GB162 | boiler | 115 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 466 | Topline/GB162 | boiler | 115 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 467 | Topline/GB162 | boiler | 115 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 468 | Topline/GB162 | boiler | 115 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 469 | Topline/GB162 | boiler | 115 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 470 | Topline/GB162 | boiler | 115 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 471 | Topline/GB162 | boiler | 115 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 472 | Topline/GB162 | boiler | 115 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 473 | Topline/GB162 | boiler | 115 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 474 | Topline/GB162 | boiler | 115 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 475 | Topline/GB162 | boiler | 115 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 476 | Topline/GB162 | boiler | 115 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 477 | Topline/GB162 | boiler | 115 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 478 | Topline/GB162 | boiler | 115 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 479 | Topline/GB162 | boiler | 115 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 480 | Topline/GB162 | boiler | 115 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 481 | Topline/GB162 | boiler | 115 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 482 | Topline/GB162 | boiler | 115 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 483 | Topline/GB162 | boiler | 115 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 484 | Topline/GB162 | boiler | 115 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 485 | Topline/GB162 | boiler | 115 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 486 | Topline/GB162 | boiler | 115 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 487 | Topline/GB162 | boiler | 115 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 488 | Topline/GB162 | boiler | 115 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 489 | Topline/GB162 | boiler | 115 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 490 | Topline/GB162 | boiler | 115 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 491 | Topline/GB162 | boiler | 115 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 492 | Topline/GB162 | boiler | 115 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 493 | Topline/GB162 | boiler | 115 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 494 | Topline/GB162 | boiler | 115 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 495 | Topline/GB162 | boiler | 115 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 496 | Topline/GB162 | boiler | 115 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 497 | Topline/GB162 | boiler | 115 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 498 | Topline/GB162 | boiler | 115 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 499 | Topline/GB162 | boiler | 115 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 500 | Topline/GB162 | boiler | 115 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 501 | Topline/GB162 | boiler | 115 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 502 | Topline/GB162 | boiler | 115 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 503 | Topline/GB162 | boiler | 115 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 504 | Topline/GB162 | boiler | 115 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 505 | Topline/GB162 | boiler | 115 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 506 | Topline/GB162 | boiler | 115 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 507 | Topline/GB162 | boiler | 115 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 508 | Topline/GB162 | boiler | 115 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 509 | Topline/GB162 | boiler | 115 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 510 | Topline/GB162 | boiler | 115 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 511 | Topline/GB162 | boiler | 115 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 512 | Topline/GB162 | boiler | 115 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 513 | Topline/GB162 | boiler | 115 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 514 | Topline/GB162 | boiler | 115 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 515 | Topline/GB162 | boiler | 115 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 516 | Topline/GB162 | boiler | 115 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 517 | Topline/GB162 | boiler | 115 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 518 | Topline/GB162 | boiler | 115 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 519 | Topline/GB162 | boiler | 115 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 520 | Topline/GB162 | boiler | 115 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 521 | Topline/GB162 | boiler | 115 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 522 | Topline/GB162 | boiler | 115 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 523 | Topline/GB162 | boiler | 115 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 524 | Topline/GB162 | boiler | 115 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 525 | Topline/GB162 | boiler | 115 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 526 | Topline/GB162 | boiler | 115 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 527 | Topline/GB162 | boiler | 115 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 528 | Topline/GB162 | boiler | 115 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 529 | Topline/GB162 | boiler | 115 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 530 | Topline/GB162 | boiler | 115 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 531 | Topline/GB162 | boiler | 115 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 532 | Topline/GB162 | boiler | 115 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 533 | Topline/GB162 | boiler | 115 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 534 | Topline/GB162 | boiler | 115 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 535 | Topline/GB162 | boiler | 115 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 536 | Topline/GB162 | boiler | 115 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 537 | Topline/GB162 | boiler | 115 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 538 | Topline/GB162 | boiler | 115 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 539 | Topline/GB162 | boiler | 115 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 540 | Topline/GB162 | boiler | 115 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 541 | Topline/GB162 | boiler | 115 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 542 | Topline/GB162 | boiler | 115 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 543 | Topline/GB162 | boiler | 115 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 544 | Topline/GB162 | boiler | 115 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 545 | Topline/GB162 | boiler | 115 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 546 | Topline/GB162 | boiler | 115 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 547 | Topline/GB162 | boiler | 115 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 548 | Cascade MCM10 | boiler | 121 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 549 | Cascade MCM10 | boiler | 121 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 550 | Cascade MCM10 | boiler | 121 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 551 | Cascade MCM10 | boiler | 121 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 552 | Cascade MCM10 | boiler | 121 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 553 | Cascade MCM10 | boiler | 121 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 554 | Cascade MCM10 | boiler | 121 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 555 | Cascade MCM10 | boiler | 121 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 556 | Cascade MCM10 | boiler | 121 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 557 | Cascade MCM10 | boiler | 121 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 558 | Cascade MCM10 | boiler | 121 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 559 | Cascade MCM10 | boiler | 121 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 560 | Cascade MCM10 | boiler | 121 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 561 | Cascade MCM10 | boiler | 121 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 562 | Cascade MCM10 | boiler | 121 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 563 | Cascade MCM10 | boiler | 121 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 564 | Cascade MCM10 | boiler | 121 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 565 | Cascade MCM10 | boiler | 121 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 566 | Cascade MCM10 | boiler | 121 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 567 | Cascade MCM10 | boiler | 121 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 568 | Cascade MCM10 | boiler | 121 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 569 | Cascade MCM10 | boiler | 121 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 570 | Cascade MCM10 | boiler | 121 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 571 | Cascade MCM10 | boiler | 121 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 572 | Cascade MCM10 | boiler | 121 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 573 | Cascade MCM10 | boiler | 121 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 574 | Cascade MCM10 | boiler | 121 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 575 | Cascade MCM10 | boiler | 121 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 576 | Cascade MCM10 | boiler | 121 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 577 | Cascade MCM10 | boiler | 121 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 578 | Cascade MCM10 | boiler | 121 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 579 | Cascade MCM10 | boiler | 121 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 580 | Cascade MCM10 | boiler | 121 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 581 | Cascade MCM10 | boiler | 121 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 582 | Cascade MCM10 | boiler | 121 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 583 | Cascade MCM10 | boiler | 121 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 584 | Cascade MCM10 | boiler | 121 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 585 | Cascade MCM10 | boiler | 121 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 586 | Cascade MCM10 | boiler | 121 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 587 | Cascade MCM10 | boiler | 121 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 588 | Cascade MCM10 | boiler | 121 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 589 | Cascade MCM10 | boiler | 121 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 590 | Cascade MCM10 | boiler | 121 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 591 | Cascade MCM10 | boiler | 121 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 592 | Cascade MCM10 | boiler | 121 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 593 | Cascade MCM10 | boiler | 121 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 594 | Cascade MCM10 | boiler | 121 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 595 | Cascade MCM10 | boiler | 121 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 596 | Cascade MCM10 | boiler | 121 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 597 | Cascade MCM10 | boiler | 121 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 598 | Cascade MCM10 | boiler | 121 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 599 | Cascade MCM10 | boiler | 121 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 600 | Cascade MCM10 | boiler | 121 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 601 | Cascade MCM10 | boiler | 121 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 602 | Cascade MCM10 | boiler | 121 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 603 | Cascade MCM10 | boiler | 121 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 604 | Cascade MCM10 | boiler | 121 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 605 | Cascade MCM10 | boiler | 121 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 606 | Cascade MCM10 | boiler | 121 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 607 | Cascade MCM10 | boiler | 121 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 608 | Cascade MCM10 | boiler | 121 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 609 | Cascade MCM10 | boiler | 121 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 610 | Cascade MCM10 | boiler | 121 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 611 | Cascade MCM10 | boiler | 121 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 612 | Cascade MCM10 | boiler | 121 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 613 | Cascade MCM10 | boiler | 121 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 614 | Cascade MCM10 | boiler | 121 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 615 | Cascade MCM10 | boiler | 121 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 616 | Cascade MCM10 | boiler | 121 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 617 | Cascade MCM10 | boiler | 121 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 618 | Cascade MCM10 | boiler | 121 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 619 | Cascade MCM10 | boiler | 121 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 620 | Cascade MCM10 | boiler | 121 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 621 | Cascade MCM10 | boiler | 121 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 622 | Cascade MCM10 | boiler | 121 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 623 | Cascade MCM10 | boiler | 121 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 624 | Cascade MCM10 | boiler | 121 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 625 | Cascade MCM10 | boiler | 121 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 626 | Cascade MCM10 | boiler | 121 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 627 | Cascade MCM10 | boiler | 121 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 628 | Cascade MCM10 | boiler | 121 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 629 | Cascade MCM10 | boiler | 121 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 630 | Cascade MCM10 | boiler | 121 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 631 | Cascade MCM10 | boiler | 121 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 632 | Cascade MCM10 | boiler | 121 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 633 | Cascade MCM10 | boiler | 121 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 634 | Cascade MCM10 | boiler | 121 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 635 | Cascade MCM10 | boiler | 121 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 636 | Cascade MCM10 | boiler | 121 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 637 | Cascade MCM10 | boiler | 121 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 638 | Cascade MCM10 | boiler | 121 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 639 | Proline | boiler | 122 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 640 | Proline | boiler | 122 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 641 | Proline | boiler | 122 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 642 | Proline | boiler | 122 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 643 | Proline | boiler | 122 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 644 | Proline | boiler | 122 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 645 | Proline | boiler | 122 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 646 | Proline | boiler | 122 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 647 | Proline | boiler | 122 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 648 | Proline | boiler | 122 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 649 | Proline | boiler | 122 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 650 | Proline | boiler | 122 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 651 | Proline | boiler | 122 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 652 | Proline | boiler | 122 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 653 | Proline | boiler | 122 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 654 | Proline | boiler | 122 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 655 | Proline | boiler | 122 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 656 | Proline | boiler | 122 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 657 | Proline | boiler | 122 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 658 | Proline | boiler | 122 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 659 | Proline | boiler | 122 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 660 | Proline | boiler | 122 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 661 | Proline | boiler | 122 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 662 | Proline | boiler | 122 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 663 | Proline | boiler | 122 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 664 | Proline | boiler | 122 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 665 | Proline | boiler | 122 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 666 | Proline | boiler | 122 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 667 | Proline | boiler | 122 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 668 | Proline | boiler | 122 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 669 | Proline | boiler | 122 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 670 | Proline | boiler | 122 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 671 | Proline | boiler | 122 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 672 | Proline | boiler | 122 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 673 | Proline | boiler | 122 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 674 | Proline | boiler | 122 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 675 | Proline | boiler | 122 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 676 | Proline | boiler | 122 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 677 | Proline | boiler | 122 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 678 | Proline | boiler | 122 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 679 | Proline | boiler | 122 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 680 | Proline | boiler | 122 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 681 | Proline | boiler | 122 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 682 | Proline | boiler | 122 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 683 | Proline | boiler | 122 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 684 | Proline | boiler | 122 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 685 | Proline | boiler | 122 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 686 | Proline | boiler | 122 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 687 | Proline | boiler | 122 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 688 | Proline | boiler | 122 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 689 | Proline | boiler | 122 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 690 | Proline | boiler | 122 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 691 | Proline | boiler | 122 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 692 | Proline | boiler | 122 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 693 | Proline | boiler | 122 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 694 | Proline | boiler | 122 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 695 | Proline | boiler | 122 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 696 | Proline | boiler | 122 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 697 | Proline | boiler | 122 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 698 | Proline | boiler | 122 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 699 | Proline | boiler | 122 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 700 | Proline | boiler | 122 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 701 | Proline | boiler | 122 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 702 | Proline | boiler | 122 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 703 | Proline | boiler | 122 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 704 | Proline | boiler | 122 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 705 | Proline | boiler | 122 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 706 | Proline | boiler | 122 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 707 | Proline | boiler | 122 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 708 | Proline | boiler | 122 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 709 | Proline | boiler | 122 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 710 | Proline | boiler | 122 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 711 | Proline | boiler | 122 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 712 | Proline | boiler | 122 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 713 | Proline | boiler | 122 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 714 | Proline | boiler | 122 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 715 | Proline | boiler | 122 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 716 | Proline | boiler | 122 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 717 | Proline | boiler | 122 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 718 | Proline | boiler | 122 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 719 | Proline | boiler | 122 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 720 | Proline | boiler | 122 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 721 | Proline | boiler | 122 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 722 | Proline | boiler | 122 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 723 | Proline | boiler | 122 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 724 | Proline | boiler | 122 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 725 | Proline | boiler | 122 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 726 | Proline | boiler | 122 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 727 | Proline | boiler | 122 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 728 | Proline | boiler | 122 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 729 | Proline | boiler | 122 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 730 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 731 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 732 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 733 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 734 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 735 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 736 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 737 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 738 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 739 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 740 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 741 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 742 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 743 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 744 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 745 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 746 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 747 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 748 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 749 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 750 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 751 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 752 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 753 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 754 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 755 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 756 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 757 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 758 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 759 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 760 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 761 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 762 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 763 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 764 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 765 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 766 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 767 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 768 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 769 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 770 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 771 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 772 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 773 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 774 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 775 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 776 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 777 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 778 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 779 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 780 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 781 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 782 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 783 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 784 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 785 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 786 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 787 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 788 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 789 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 790 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 791 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 792 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 793 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 794 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 795 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 796 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 797 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 798 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 799 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 800 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 801 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 802 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 803 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 804 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 805 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 806 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 807 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 808 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 809 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 810 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 811 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 812 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 813 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 814 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 815 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 816 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 817 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 818 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 819 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 820 | GBx72/Trendline/Cerapur/Greenstar Si | boiler | 123 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 821 | GB212 | boiler | 131 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 822 | GB212 | boiler | 131 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 823 | GB212 | boiler | 131 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 824 | GB212 | boiler | 131 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 825 | GB212 | boiler | 131 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 826 | GB212 | boiler | 131 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 827 | GB212 | boiler | 131 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 828 | GB212 | boiler | 131 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 829 | GB212 | boiler | 131 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 830 | GB212 | boiler | 131 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 831 | GB212 | boiler | 131 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 832 | GB212 | boiler | 131 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 833 | GB212 | boiler | 131 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 834 | GB212 | boiler | 131 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 835 | GB212 | boiler | 131 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 836 | GB212 | boiler | 131 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 837 | GB212 | boiler | 131 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 838 | GB212 | boiler | 131 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 839 | GB212 | boiler | 131 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 840 | GB212 | boiler | 131 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 841 | GB212 | boiler | 131 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 842 | GB212 | boiler | 131 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 843 | GB212 | boiler | 131 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 844 | GB212 | boiler | 131 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 845 | GB212 | boiler | 131 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 846 | GB212 | boiler | 131 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 847 | GB212 | boiler | 131 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 848 | GB212 | boiler | 131 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 849 | GB212 | boiler | 131 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 850 | GB212 | boiler | 131 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 851 | GB212 | boiler | 131 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 852 | GB212 | boiler | 131 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 853 | GB212 | boiler | 131 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 854 | GB212 | boiler | 131 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 855 | GB212 | boiler | 131 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 856 | GB212 | boiler | 131 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 857 | GB212 | boiler | 131 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 858 | GB212 | boiler | 131 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 859 | GB212 | boiler | 131 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 860 | GB212 | boiler | 131 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 861 | GB212 | boiler | 131 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 862 | GB212 | boiler | 131 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 863 | GB212 | boiler | 131 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 864 | GB212 | boiler | 131 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 865 | GB212 | boiler | 131 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 866 | GB212 | boiler | 131 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 867 | GB212 | boiler | 131 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 868 | GB212 | boiler | 131 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 869 | GB212 | boiler | 131 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 870 | GB212 | boiler | 131 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 871 | GB212 | boiler | 131 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 872 | GB212 | boiler | 131 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 873 | GB212 | boiler | 131 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 874 | GB212 | boiler | 131 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 875 | GB212 | boiler | 131 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 876 | GB212 | boiler | 131 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 877 | GB212 | boiler | 131 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 878 | GB212 | boiler | 131 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 879 | GB212 | boiler | 131 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 880 | GB212 | boiler | 131 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 881 | GB212 | boiler | 131 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 882 | GB212 | boiler | 131 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 883 | GB212 | boiler | 131 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 884 | GB212 | boiler | 131 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 885 | GB212 | boiler | 131 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 886 | GB212 | boiler | 131 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 887 | GB212 | boiler | 131 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 888 | GB212 | boiler | 131 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 889 | GB212 | boiler | 131 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 890 | GB212 | boiler | 131 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 891 | GB212 | boiler | 131 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 892 | GB212 | boiler | 131 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 893 | GB212 | boiler | 131 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 894 | GB212 | boiler | 131 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 895 | GB212 | boiler | 131 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 896 | GB212 | boiler | 131 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 897 | GB212 | boiler | 131 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 898 | GB212 | boiler | 131 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 899 | GB212 | boiler | 131 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 900 | GB212 | boiler | 131 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 901 | GB212 | boiler | 131 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 902 | GB212 | boiler | 131 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 903 | GB212 | boiler | 131 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 904 | GB212 | boiler | 131 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 905 | GB212 | boiler | 131 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 906 | GB212 | boiler | 131 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 907 | GB212 | boiler | 131 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 908 | GB212 | boiler | 131 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 909 | GB212 | boiler | 131 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 910 | GB212 | boiler | 131 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 911 | GB212 | boiler | 131 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 912 | GC7000F | boiler | 132 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 913 | GC7000F | boiler | 132 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 914 | GC7000F | boiler | 132 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 915 | GC7000F | boiler | 132 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 916 | GC7000F | boiler | 132 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 917 | GC7000F | boiler | 132 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 918 | GC7000F | boiler | 132 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 919 | GC7000F | boiler | 132 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 920 | GC7000F | boiler | 132 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 921 | GC7000F | boiler | 132 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 922 | GC7000F | boiler | 132 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 923 | GC7000F | boiler | 132 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 924 | GC7000F | boiler | 132 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 925 | GC7000F | boiler | 132 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 926 | GC7000F | boiler | 132 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 927 | GC7000F | boiler | 132 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 928 | GC7000F | boiler | 132 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 929 | GC7000F | boiler | 132 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 930 | GC7000F | boiler | 132 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 931 | GC7000F | boiler | 132 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 932 | GC7000F | boiler | 132 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 933 | GC7000F | boiler | 132 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 934 | GC7000F | boiler | 132 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 935 | GC7000F | boiler | 132 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 936 | GC7000F | boiler | 132 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 937 | GC7000F | boiler | 132 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 938 | GC7000F | boiler | 132 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 939 | GC7000F | boiler | 132 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 940 | GC7000F | boiler | 132 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 941 | GC7000F | boiler | 132 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 942 | GC7000F | boiler | 132 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 943 | GC7000F | boiler | 132 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 944 | GC7000F | boiler | 132 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 945 | GC7000F | boiler | 132 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 946 | GC7000F | boiler | 132 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 947 | GC7000F | boiler | 132 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 948 | GC7000F | boiler | 132 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 949 | GC7000F | boiler | 132 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 950 | GC7000F | boiler | 132 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 951 | GC7000F | boiler | 132 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 952 | GC7000F | boiler | 132 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 953 | GC7000F | boiler | 132 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 954 | GC7000F | boiler | 132 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 955 | GC7000F | boiler | 132 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 956 | GC7000F | boiler | 132 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 957 | GC7000F | boiler | 132 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 958 | GC7000F | boiler | 132 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 959 | GC7000F | boiler | 132 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 960 | GC7000F | boiler | 132 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 961 | GC7000F | boiler | 132 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 962 | GC7000F | boiler | 132 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 963 | GC7000F | boiler | 132 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 964 | GC7000F | boiler | 132 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 965 | GC7000F | boiler | 132 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 966 | GC7000F | boiler | 132 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 967 | GC7000F | boiler | 132 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 968 | GC7000F | boiler | 132 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 969 | GC7000F | boiler | 132 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 970 | GC7000F | boiler | 132 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 971 | GC7000F | boiler | 132 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 972 | GC7000F | boiler | 132 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 973 | GC7000F | boiler | 132 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 974 | GC7000F | boiler | 132 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 975 | GC7000F | boiler | 132 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 976 | GC7000F | boiler | 132 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 977 | GC7000F | boiler | 132 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 978 | GC7000F | boiler | 132 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 979 | GC7000F | boiler | 132 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 980 | GC7000F | boiler | 132 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 981 | GC7000F | boiler | 132 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 982 | GC7000F | boiler | 132 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 983 | GC7000F | boiler | 132 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 984 | GC7000F | boiler | 132 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 985 | GC7000F | boiler | 132 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 986 | GC7000F | boiler | 132 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 987 | GC7000F | boiler | 132 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 988 | GC7000F | boiler | 132 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 989 | GC7000F | boiler | 132 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 990 | GC7000F | boiler | 132 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 991 | GC7000F | boiler | 132 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 992 | GC7000F | boiler | 132 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 993 | GC7000F | boiler | 132 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 994 | GC7000F | boiler | 132 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 995 | GC7000F | boiler | 132 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 996 | GC7000F | boiler | 132 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 997 | GC7000F | boiler | 132 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 998 | GC7000F | boiler | 132 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 999 | GC7000F | boiler | 132 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 1000 | GC7000F | boiler | 132 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 1001 | GC7000F | boiler | 132 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 1002 | GC7000F | boiler | 132 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 1003 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 1004 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 1005 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 1006 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 1007 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 1008 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 1009 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 1010 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 1011 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 1012 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 1013 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 1014 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 1015 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 1016 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 1017 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 1018 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 1019 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 1020 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 1021 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 1022 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 1023 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 1024 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 1025 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 1026 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 1027 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 1028 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 1029 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 1030 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 1031 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 1032 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 1033 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 1034 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 1035 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 1036 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 1037 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 1038 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 1039 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 1040 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 1041 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 1042 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 1043 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 1044 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 1045 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 1046 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 1047 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 1048 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 1049 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 1050 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 1051 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 1052 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 1053 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 1054 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 1055 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 1056 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 1057 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 1058 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 1059 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 1060 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 1061 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 1062 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 1063 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 1064 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 1065 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 1066 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 1067 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 1068 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 1069 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 1070 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 1071 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 1072 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 1073 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 1074 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 1075 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 1076 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 1077 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 1078 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 1079 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 1080 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 1081 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 1082 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 1083 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 1084 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 1085 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 1086 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 1087 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 1088 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 1089 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 1090 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 1091 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 1092 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 1093 | Logano GB125/KB195i/Logamatic MC110 | boiler | 133 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 1094 | Greenstar 30Ri Compact | boiler | 154 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 1095 | Greenstar 30Ri Compact | boiler | 154 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 1096 | Greenstar 30Ri Compact | boiler | 154 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 1097 | Greenstar 30Ri Compact | boiler | 154 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 1098 | Greenstar 30Ri Compact | boiler | 154 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 1099 | Greenstar 30Ri Compact | boiler | 154 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 1100 | Greenstar 30Ri Compact | boiler | 154 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 1101 | Greenstar 30Ri Compact | boiler | 154 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 1102 | Greenstar 30Ri Compact | boiler | 154 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 1103 | Greenstar 30Ri Compact | boiler | 154 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 1104 | Greenstar 30Ri Compact | boiler | 154 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 1105 | Greenstar 30Ri Compact | boiler | 154 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 1106 | Greenstar 30Ri Compact | boiler | 154 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 1107 | Greenstar 30Ri Compact | boiler | 154 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 1108 | Greenstar 30Ri Compact | boiler | 154 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 1109 | Greenstar 30Ri Compact | boiler | 154 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 1110 | Greenstar 30Ri Compact | boiler | 154 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 1111 | Greenstar 30Ri Compact | boiler | 154 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 1112 | Greenstar 30Ri Compact | boiler | 154 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 1113 | Greenstar 30Ri Compact | boiler | 154 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 1114 | Greenstar 30Ri Compact | boiler | 154 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 1115 | Greenstar 30Ri Compact | boiler | 154 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 1116 | Greenstar 30Ri Compact | boiler | 154 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 1117 | Greenstar 30Ri Compact | boiler | 154 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 1118 | Greenstar 30Ri Compact | boiler | 154 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 1119 | Greenstar 30Ri Compact | boiler | 154 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 1120 | Greenstar 30Ri Compact | boiler | 154 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 1121 | Greenstar 30Ri Compact | boiler | 154 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 1122 | Greenstar 30Ri Compact | boiler | 154 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 1123 | Greenstar 30Ri Compact | boiler | 154 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 1124 | Greenstar 30Ri Compact | boiler | 154 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 1125 | Greenstar 30Ri Compact | boiler | 154 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 1126 | Greenstar 30Ri Compact | boiler | 154 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 1127 | Greenstar 30Ri Compact | boiler | 154 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 1128 | Greenstar 30Ri Compact | boiler | 154 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 1129 | Greenstar 30Ri Compact | boiler | 154 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 1130 | Greenstar 30Ri Compact | boiler | 154 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 1131 | Greenstar 30Ri Compact | boiler | 154 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 1132 | Greenstar 30Ri Compact | boiler | 154 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 1133 | Greenstar 30Ri Compact | boiler | 154 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 1134 | Greenstar 30Ri Compact | boiler | 154 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 1135 | Greenstar 30Ri Compact | boiler | 154 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 1136 | Greenstar 30Ri Compact | boiler | 154 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 1137 | Greenstar 30Ri Compact | boiler | 154 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 1138 | Greenstar 30Ri Compact | boiler | 154 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 1139 | Greenstar 30Ri Compact | boiler | 154 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 1140 | Greenstar 30Ri Compact | boiler | 154 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 1141 | Greenstar 30Ri Compact | boiler | 154 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 1142 | Greenstar 30Ri Compact | boiler | 154 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 1143 | Greenstar 30Ri Compact | boiler | 154 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 1144 | Greenstar 30Ri Compact | boiler | 154 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 1145 | Greenstar 30Ri Compact | boiler | 154 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 1146 | Greenstar 30Ri Compact | boiler | 154 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 1147 | Greenstar 30Ri Compact | boiler | 154 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 1148 | Greenstar 30Ri Compact | boiler | 154 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 1149 | Greenstar 30Ri Compact | boiler | 154 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 1150 | Greenstar 30Ri Compact | boiler | 154 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 1151 | Greenstar 30Ri Compact | boiler | 154 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 1152 | Greenstar 30Ri Compact | boiler | 154 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 1153 | Greenstar 30Ri Compact | boiler | 154 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 1154 | Greenstar 30Ri Compact | boiler | 154 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 1155 | Greenstar 30Ri Compact | boiler | 154 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 1156 | Greenstar 30Ri Compact | boiler | 154 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 1157 | Greenstar 30Ri Compact | boiler | 154 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 1158 | Greenstar 30Ri Compact | boiler | 154 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 1159 | Greenstar 30Ri Compact | boiler | 154 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 1160 | Greenstar 30Ri Compact | boiler | 154 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 1161 | Greenstar 30Ri Compact | boiler | 154 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 1162 | Greenstar 30Ri Compact | boiler | 154 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 1163 | Greenstar 30Ri Compact | boiler | 154 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 1164 | Greenstar 30Ri Compact | boiler | 154 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 1165 | Greenstar 30Ri Compact | boiler | 154 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 1166 | Greenstar 30Ri Compact | boiler | 154 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 1167 | Greenstar 30Ri Compact | boiler | 154 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 1168 | Greenstar 30Ri Compact | boiler | 154 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 1169 | Greenstar 30Ri Compact | boiler | 154 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 1170 | Greenstar 30Ri Compact | boiler | 154 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 1171 | Greenstar 30Ri Compact | boiler | 154 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 1172 | Greenstar 30Ri Compact | boiler | 154 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 1173 | Greenstar 30Ri Compact | boiler | 154 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 1174 | Greenstar 30Ri Compact | boiler | 154 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 1175 | Greenstar 30Ri Compact | boiler | 154 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 1176 | Greenstar 30Ri Compact | boiler | 154 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 1177 | Greenstar 30Ri Compact | boiler | 154 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 1178 | Greenstar 30Ri Compact | boiler | 154 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 1179 | Greenstar 30Ri Compact | boiler | 154 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 1180 | Greenstar 30Ri Compact | boiler | 154 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 1181 | Greenstar 30Ri Compact | boiler | 154 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 1182 | Greenstar 30Ri Compact | boiler | 154 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 1183 | Greenstar 30Ri Compact | boiler | 154 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 1184 | Greenstar 30Ri Compact | boiler | 154 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 1185 | Cerapur Aero | boiler | 167 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 1186 | Cerapur Aero | boiler | 167 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 1187 | Cerapur Aero | boiler | 167 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 1188 | Cerapur Aero | boiler | 167 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 1189 | Cerapur Aero | boiler | 167 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 1190 | Cerapur Aero | boiler | 167 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 1191 | Cerapur Aero | boiler | 167 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 1192 | Cerapur Aero | boiler | 167 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 1193 | Cerapur Aero | boiler | 167 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 1194 | Cerapur Aero | boiler | 167 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 1195 | Cerapur Aero | boiler | 167 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 1196 | Cerapur Aero | boiler | 167 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 1197 | Cerapur Aero | boiler | 167 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 1198 | Cerapur Aero | boiler | 167 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 1199 | Cerapur Aero | boiler | 167 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 1200 | Cerapur Aero | boiler | 167 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 1201 | Cerapur Aero | boiler | 167 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 1202 | Cerapur Aero | boiler | 167 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 1203 | Cerapur Aero | boiler | 167 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 1204 | Cerapur Aero | boiler | 167 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 1205 | Cerapur Aero | boiler | 167 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 1206 | Cerapur Aero | boiler | 167 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 1207 | Cerapur Aero | boiler | 167 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 1208 | Cerapur Aero | boiler | 167 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 1209 | Cerapur Aero | boiler | 167 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 1210 | Cerapur Aero | boiler | 167 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 1211 | Cerapur Aero | boiler | 167 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 1212 | Cerapur Aero | boiler | 167 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 1213 | Cerapur Aero | boiler | 167 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 1214 | Cerapur Aero | boiler | 167 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 1215 | Cerapur Aero | boiler | 167 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 1216 | Cerapur Aero | boiler | 167 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 1217 | Cerapur Aero | boiler | 167 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 1218 | Cerapur Aero | boiler | 167 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 1219 | Cerapur Aero | boiler | 167 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 1220 | Cerapur Aero | boiler | 167 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 1221 | Cerapur Aero | boiler | 167 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 1222 | Cerapur Aero | boiler | 167 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 1223 | Cerapur Aero | boiler | 167 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 1224 | Cerapur Aero | boiler | 167 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 1225 | Cerapur Aero | boiler | 167 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 1226 | Cerapur Aero | boiler | 167 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 1227 | Cerapur Aero | boiler | 167 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 1228 | Cerapur Aero | boiler | 167 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 1229 | Cerapur Aero | boiler | 167 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 1230 | Cerapur Aero | boiler | 167 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 1231 | Cerapur Aero | boiler | 167 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 1232 | Cerapur Aero | boiler | 167 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 1233 | Cerapur Aero | boiler | 167 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 1234 | Cerapur Aero | boiler | 167 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 1235 | Cerapur Aero | boiler | 167 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 1236 | Cerapur Aero | boiler | 167 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 1237 | Cerapur Aero | boiler | 167 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 1238 | Cerapur Aero | boiler | 167 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 1239 | Cerapur Aero | boiler | 167 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 1240 | Cerapur Aero | boiler | 167 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 1241 | Cerapur Aero | boiler | 167 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 1242 | Cerapur Aero | boiler | 167 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 1243 | Cerapur Aero | boiler | 167 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 1244 | Cerapur Aero | boiler | 167 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 1245 | Cerapur Aero | boiler | 167 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 1246 | Cerapur Aero | boiler | 167 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 1247 | Cerapur Aero | boiler | 167 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 1248 | Cerapur Aero | boiler | 167 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 1249 | Cerapur Aero | boiler | 167 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 1250 | Cerapur Aero | boiler | 167 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 1251 | Cerapur Aero | boiler | 167 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 1252 | Cerapur Aero | boiler | 167 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 1253 | Cerapur Aero | boiler | 167 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 1254 | Cerapur Aero | boiler | 167 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 1255 | Cerapur Aero | boiler | 167 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 1256 | Cerapur Aero | boiler | 167 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 1257 | Cerapur Aero | boiler | 167 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 1258 | Cerapur Aero | boiler | 167 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 1259 | Cerapur Aero | boiler | 167 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 1260 | Cerapur Aero | boiler | 167 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 1261 | Cerapur Aero | boiler | 167 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 1262 | Cerapur Aero | boiler | 167 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 1263 | Cerapur Aero | boiler | 167 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 1264 | Cerapur Aero | boiler | 167 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 1265 | Cerapur Aero | boiler | 167 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 1266 | Cerapur Aero | boiler | 167 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 1267 | Cerapur Aero | boiler | 167 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 1268 | Cerapur Aero | boiler | 167 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 1269 | Cerapur Aero | boiler | 167 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 1270 | Cerapur Aero | boiler | 167 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 1271 | Cerapur Aero | boiler | 167 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 1272 | Cerapur Aero | boiler | 167 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 1273 | Cerapur Aero | boiler | 167 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 1274 | Cerapur Aero | boiler | 167 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 1275 | Cerapur Aero | boiler | 167 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 1276 | Hybrid Heatpump | boiler | 168 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 1277 | Hybrid Heatpump | boiler | 168 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 1278 | Hybrid Heatpump | boiler | 168 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 1279 | Hybrid Heatpump | boiler | 168 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 1280 | Hybrid Heatpump | boiler | 168 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 1281 | Hybrid Heatpump | boiler | 168 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 1282 | Hybrid Heatpump | boiler | 168 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 1283 | Hybrid Heatpump | boiler | 168 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 1284 | Hybrid Heatpump | boiler | 168 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 1285 | Hybrid Heatpump | boiler | 168 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 1286 | Hybrid Heatpump | boiler | 168 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 1287 | Hybrid Heatpump | boiler | 168 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 1288 | Hybrid Heatpump | boiler | 168 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 1289 | Hybrid Heatpump | boiler | 168 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 1290 | Hybrid Heatpump | boiler | 168 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 1291 | Hybrid Heatpump | boiler | 168 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 1292 | Hybrid Heatpump | boiler | 168 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 1293 | Hybrid Heatpump | boiler | 168 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 1294 | Hybrid Heatpump | boiler | 168 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 1295 | Hybrid Heatpump | boiler | 168 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 1296 | Hybrid Heatpump | boiler | 168 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 1297 | Hybrid Heatpump | boiler | 168 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 1298 | Hybrid Heatpump | boiler | 168 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 1299 | Hybrid Heatpump | boiler | 168 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 1300 | Hybrid Heatpump | boiler | 168 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 1301 | Hybrid Heatpump | boiler | 168 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 1302 | Hybrid Heatpump | boiler | 168 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 1303 | Hybrid Heatpump | boiler | 168 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 1304 | Hybrid Heatpump | boiler | 168 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 1305 | Hybrid Heatpump | boiler | 168 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 1306 | Hybrid Heatpump | boiler | 168 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 1307 | Hybrid Heatpump | boiler | 168 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 1308 | Hybrid Heatpump | boiler | 168 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 1309 | Hybrid Heatpump | boiler | 168 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 1310 | Hybrid Heatpump | boiler | 168 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 1311 | Hybrid Heatpump | boiler | 168 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 1312 | Hybrid Heatpump | boiler | 168 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 1313 | Hybrid Heatpump | boiler | 168 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 1314 | Hybrid Heatpump | boiler | 168 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 1315 | Hybrid Heatpump | boiler | 168 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 1316 | Hybrid Heatpump | boiler | 168 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 1317 | Hybrid Heatpump | boiler | 168 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 1318 | Hybrid Heatpump | boiler | 168 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 1319 | Hybrid Heatpump | boiler | 168 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 1320 | Hybrid Heatpump | boiler | 168 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 1321 | Hybrid Heatpump | boiler | 168 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 1322 | Hybrid Heatpump | boiler | 168 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 1323 | Hybrid Heatpump | boiler | 168 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 1324 | Hybrid Heatpump | boiler | 168 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 1325 | Hybrid Heatpump | boiler | 168 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 1326 | Hybrid Heatpump | boiler | 168 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 1327 | Hybrid Heatpump | boiler | 168 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 1328 | Hybrid Heatpump | boiler | 168 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 1329 | Hybrid Heatpump | boiler | 168 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 1330 | Hybrid Heatpump | boiler | 168 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 1331 | Hybrid Heatpump | boiler | 168 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 1332 | Hybrid Heatpump | boiler | 168 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 1333 | Hybrid Heatpump | boiler | 168 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 1334 | Hybrid Heatpump | boiler | 168 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 1335 | Hybrid Heatpump | boiler | 168 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 1336 | Hybrid Heatpump | boiler | 168 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 1337 | Hybrid Heatpump | boiler | 168 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 1338 | Hybrid Heatpump | boiler | 168 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 1339 | Hybrid Heatpump | boiler | 168 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 1340 | Hybrid Heatpump | boiler | 168 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 1341 | Hybrid Heatpump | boiler | 168 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 1342 | Hybrid Heatpump | boiler | 168 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 1343 | Hybrid Heatpump | boiler | 168 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 1344 | Hybrid Heatpump | boiler | 168 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 1345 | Hybrid Heatpump | boiler | 168 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 1346 | Hybrid Heatpump | boiler | 168 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 1347 | Hybrid Heatpump | boiler | 168 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 1348 | Hybrid Heatpump | boiler | 168 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 1349 | Hybrid Heatpump | boiler | 168 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 1350 | Hybrid Heatpump | boiler | 168 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 1351 | Hybrid Heatpump | boiler | 168 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 1352 | Hybrid Heatpump | boiler | 168 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 1353 | Hybrid Heatpump | boiler | 168 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 1354 | Hybrid Heatpump | boiler | 168 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 1355 | Hybrid Heatpump | boiler | 168 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 1356 | Hybrid Heatpump | boiler | 168 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 1357 | Hybrid Heatpump | boiler | 168 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 1358 | Hybrid Heatpump | boiler | 168 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 1359 | Hybrid Heatpump | boiler | 168 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 1360 | Hybrid Heatpump | boiler | 168 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 1361 | Hybrid Heatpump | boiler | 168 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 1362 | Hybrid Heatpump | boiler | 168 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 1363 | Hybrid Heatpump | boiler | 168 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 1364 | Hybrid Heatpump | boiler | 168 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 1365 | Hybrid Heatpump | boiler | 168 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 1366 | Hybrid Heatpump | boiler | 168 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 1367 | Logano GB212 | boiler | 170 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 1368 | Logano GB212 | boiler | 170 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 1369 | Logano GB212 | boiler | 170 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 1370 | Logano GB212 | boiler | 170 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 1371 | Logano GB212 | boiler | 170 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 1372 | Logano GB212 | boiler | 170 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 1373 | Logano GB212 | boiler | 170 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 1374 | Logano GB212 | boiler | 170 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 1375 | Logano GB212 | boiler | 170 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 1376 | Logano GB212 | boiler | 170 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 1377 | Logano GB212 | boiler | 170 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 1378 | Logano GB212 | boiler | 170 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 1379 | Logano GB212 | boiler | 170 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 1380 | Logano GB212 | boiler | 170 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 1381 | Logano GB212 | boiler | 170 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 1382 | Logano GB212 | boiler | 170 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 1383 | Logano GB212 | boiler | 170 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 1384 | Logano GB212 | boiler | 170 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 1385 | Logano GB212 | boiler | 170 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 1386 | Logano GB212 | boiler | 170 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 1387 | Logano GB212 | boiler | 170 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 1388 | Logano GB212 | boiler | 170 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 1389 | Logano GB212 | boiler | 170 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 1390 | Logano GB212 | boiler | 170 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 1391 | Logano GB212 | boiler | 170 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 1392 | Logano GB212 | boiler | 170 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 1393 | Logano GB212 | boiler | 170 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 1394 | Logano GB212 | boiler | 170 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 1395 | Logano GB212 | boiler | 170 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 1396 | Logano GB212 | boiler | 170 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 1397 | Logano GB212 | boiler | 170 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 1398 | Logano GB212 | boiler | 170 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 1399 | Logano GB212 | boiler | 170 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 1400 | Logano GB212 | boiler | 170 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 1401 | Logano GB212 | boiler | 170 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 1402 | Logano GB212 | boiler | 170 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 1403 | Logano GB212 | boiler | 170 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 1404 | Logano GB212 | boiler | 170 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 1405 | Logano GB212 | boiler | 170 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 1406 | Logano GB212 | boiler | 170 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 1407 | Logano GB212 | boiler | 170 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 1408 | Logano GB212 | boiler | 170 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 1409 | Logano GB212 | boiler | 170 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 1410 | Logano GB212 | boiler | 170 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 1411 | Logano GB212 | boiler | 170 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 1412 | Logano GB212 | boiler | 170 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 1413 | Logano GB212 | boiler | 170 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 1414 | Logano GB212 | boiler | 170 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 1415 | Logano GB212 | boiler | 170 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 1416 | Logano GB212 | boiler | 170 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 1417 | Logano GB212 | boiler | 170 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 1418 | Logano GB212 | boiler | 170 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 1419 | Logano GB212 | boiler | 170 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 1420 | Logano GB212 | boiler | 170 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 1421 | Logano GB212 | boiler | 170 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 1422 | Logano GB212 | boiler | 170 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 1423 | Logano GB212 | boiler | 170 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 1424 | Logano GB212 | boiler | 170 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 1425 | Logano GB212 | boiler | 170 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 1426 | Logano GB212 | boiler | 170 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 1427 | Logano GB212 | boiler | 170 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 1428 | Logano GB212 | boiler | 170 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 1429 | Logano GB212 | boiler | 170 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 1430 | Logano GB212 | boiler | 170 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 1431 | Logano GB212 | boiler | 170 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 1432 | Logano GB212 | boiler | 170 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 1433 | Logano GB212 | boiler | 170 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 1434 | Logano GB212 | boiler | 170 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 1435 | Logano GB212 | boiler | 170 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 1436 | Logano GB212 | boiler | 170 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 1437 | Logano GB212 | boiler | 170 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 1438 | Logano GB212 | boiler | 170 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 1439 | Logano GB212 | boiler | 170 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 1440 | Logano GB212 | boiler | 170 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 1441 | Logano GB212 | boiler | 170 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 1442 | Logano GB212 | boiler | 170 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 1443 | Logano GB212 | boiler | 170 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 1444 | Logano GB212 | boiler | 170 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 1445 | Logano GB212 | boiler | 170 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 1446 | Logano GB212 | boiler | 170 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 1447 | Logano GB212 | boiler | 170 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 1448 | Logano GB212 | boiler | 170 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 1449 | Logano GB212 | boiler | 170 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 1450 | Logano GB212 | boiler | 170 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 1451 | Logano GB212 | boiler | 170 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 1452 | Logano GB212 | boiler | 170 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 1453 | Logano GB212 | boiler | 170 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 1454 | Logano GB212 | boiler | 170 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 1455 | Logano GB212 | boiler | 170 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 1456 | Logano GB212 | boiler | 170 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 1457 | Logano GB212 | boiler | 170 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 1458 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 1459 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 1460 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 1461 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 1462 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 1463 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 1464 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 1465 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 1466 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 1467 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 1468 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 1469 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 1470 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 1471 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 1472 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 1473 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 1474 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 1475 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 1476 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 1477 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 1478 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 1479 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 1480 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 1481 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 1482 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 1483 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 1484 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 1485 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 1486 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 1487 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 1488 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 1489 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 1490 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 1491 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 1492 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 1493 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 1494 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 1495 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 1496 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 1497 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 1498 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 1499 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 1500 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 1501 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 1502 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 1503 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 1504 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 1505 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 1506 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 1507 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 1508 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 1509 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 1510 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | uptimecontrol | total operating time heat | time (>=0<=17476) | minutes | false | sensor.boiler_total_operating_time_heat | sensor.boiler_uptimecontrol |
| 1511 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | uptimecompheating | operating time compressor heating | time (>=0<=17476) | minutes | false | sensor.boiler_operating_time_compressor_heating | sensor.boiler_uptimecompheating |
| 1512 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | uptimecompcooling | operating time compressor cooling | time (>=0<=17476) | minutes | false | sensor.boiler_operating_time_compressor_cooling | sensor.boiler_uptimecompcooling |
| 1513 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | uptimecompww | operating time compressor dhw | time (>=0<=17476) | minutes | false | sensor.boiler_operating_time_compressor_dhw | sensor.boiler_uptimecompww |
| 1514 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | uptimecomppool | operating time compressor pool | time (>=0<=17476) | minutes | false | sensor.boiler_operating_time_compressor_pool | sensor.boiler_uptimecomppool |
| 1515 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | totalcompstarts | total compressor control starts | ulong (>=0<=65533) | false | sensor.boiler_total_compressor_control_starts | sensor.boiler_totalcompstarts | |
| 1516 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatingstarts | heating control starts | ulong (>=0<=65533) | false | sensor.boiler_heating_control_starts | sensor.boiler_heatingstarts | |
| 1517 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | coolingstarts | cooling control starts | ulong (>=0<=65533) | false | sensor.boiler_cooling_control_starts | sensor.boiler_coolingstarts | |
| 1518 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwstarts2 | control starts2 | ulong (>=0<=65533) | false | sensor.boiler_control_starts2 | sensor.boiler_wwstarts2 | |
| 1519 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | poolstarts | pool control starts | ulong (>=0<=65533) | false | sensor.boiler_pool_control_starts | sensor.boiler_poolstarts | |
| 1520 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconstotal | total energy consumption | ulong (>=0<=65533) | kWh | false | sensor.boiler_total_energy_consumption | sensor.boiler_nrgconstotal |
| 1521 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconscomptotal | total energy consumption compressor | ulong (>=0<=65533) | kWh | false | sensor.boiler_total_energy_consumption_compressor | sensor.boiler_nrgconscomptotal |
| 1522 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconscompheating | energy consumption compressor heating | ulong (>=0<=65533) | kWh | false | sensor.boiler_energy_consumption_compressor_heating | sensor.boiler_nrgconscompheating |
| 1523 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconscompww | energy consumption compressor dhw | ulong (>=0<=65533) | kWh | false | sensor.boiler_energy_consumption_compressor_dhw | sensor.boiler_nrgconscompww |
| 1524 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconscompcooling | energy consumption compressor cooling | ulong (>=0<=65533) | kWh | false | sensor.boiler_energy_consumption_compressor_cooling | sensor.boiler_nrgconscompcooling |
| 1525 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgconscomppool | energy consumption compressor pool | ulong (>=0<=65533) | kWh | false | sensor.boiler_energy_consumption_compressor_pool | sensor.boiler_nrgconscomppool |
| 1526 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxelecheatnrgconstotal | total aux elec. heater energy consumption | ulong (>=0<=65533) | kWh | false | sensor.boiler_total_aux_elec._heater_energy_consumption | sensor.boiler_auxelecheatnrgconstotal |
| 1527 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxelecheatnrgconsheating | aux elec. heater energy consumption heating | ulong (>=0<=65533) | kWh | false | sensor.boiler_aux_elec._heater_energy_consumption_heating | sensor.boiler_auxelecheatnrgconsheating |
| 1528 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxelecheatnrgconsww | aux elec. heater energy consumption dhw | ulong (>=0<=65533) | kWh | false | sensor.boiler_aux_elec._heater_energy_consumption_dhw | sensor.boiler_auxelecheatnrgconsww |
| 1529 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxelecheatnrgconspool | aux elec. heater energy consumption pool | ulong (>=0<=65533) | kWh | false | sensor.boiler_aux_elec._heater_energy_consumption_pool | sensor.boiler_auxelecheatnrgconspool |
| 1530 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgsupptotal | total energy supplied | ulong (>=0<=65533) | kWh | false | sensor.boiler_total_energy_supplied | sensor.boiler_nrgsupptotal |
| 1531 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgsuppheating | total energy supplied heating | ulong (>=0<=65533) | kWh | false | sensor.boiler_total_energy_supplied_heating | sensor.boiler_nrgsuppheating |
| 1532 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgsuppww | total energy warm supplied dhw | ulong (>=0<=65533) | kWh | false | sensor.boiler_total_energy_warm_supplied_dhw | sensor.boiler_nrgsuppww |
| 1533 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgsuppcooling | total energy supplied cooling | ulong (>=0<=65533) | kWh | false | sensor.boiler_total_energy_supplied_cooling | sensor.boiler_nrgsuppcooling |
| 1534 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | nrgsupppool | total energy supplied pool | ulong (>=0<=65533) | kWh | false | sensor.boiler_total_energy_supplied_pool | sensor.boiler_nrgsupppool |
| 1535 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hppower | compressor power output | uint (>=0<=25) | kW | false | sensor.boiler_compressor_power_output | sensor.boiler_hppower |
| 1536 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpcompon | hp compressor | boolean | false | binary_sensor.boiler_hp_compressor | binary_sensor.boiler_hpcompon | |
| 1537 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpactivity | compressor activity | enum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost] | false | sensor.boiler_compressor_activity | sensor.boiler_hpactivity | |
| 1538 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpheatingon | hp heating | boolean | false | binary_sensor.boiler_hp_heating | binary_sensor.boiler_hpheatingon | |
| 1539 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpcoolingon | hp cooling | boolean | false | binary_sensor.boiler_hp_cooling | binary_sensor.boiler_hpcoolingon | |
| 1540 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpwwon | hp dhw | boolean | false | binary_sensor.boiler_hp_dhw | binary_sensor.boiler_hpwwon | |
| 1541 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hppoolon | hp pool | boolean | false | binary_sensor.boiler_hp_pool | binary_sensor.boiler_hppoolon | |
| 1542 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpbrinepumpspd | brine pump speed | uint (>=0<=100) | % | false | sensor.boiler_brine_pump_speed | sensor.boiler_hpbrinepumpspd |
| 1543 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpswitchvalve | switch valve | boolean | false | binary_sensor.boiler_switch_valve | binary_sensor.boiler_hpswitchvalve | |
| 1544 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpcompspd | compressor speed | uint (>=0<=100) | % | false | sensor.boiler_compressor_speed | sensor.boiler_hpcompspd |
| 1545 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpcircspd | circulation pump speed | uint (>=0<=100) | % | false | sensor.boiler_circulation_pump_speed | sensor.boiler_hpcircspd |
| 1546 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpbrinein | brine in/evaporator | short (>=-3199<=3199) | C | false | sensor.boiler_brine_in/evaporator | sensor.boiler_hpbrinein |
| 1547 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpbrineout | brine out/condenser | short (>=-3199<=3199) | C | false | sensor.boiler_brine_out/condenser | sensor.boiler_hpbrineout |
| 1548 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptc0 | heat carrier return (TC0) | short (>=-3199<=3199) | C | false | sensor.boiler_heat_carrier_return_(TC0) | sensor.boiler_hptc0 |
| 1549 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptc1 | heat carrier forward (TC1) | short (>=-3199<=3199) | C | false | sensor.boiler_heat_carrier_forward_(TC1) | sensor.boiler_hptc1 |
| 1550 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptc3 | condenser temperature (TC3) | short (>=-3199<=3199) | C | false | sensor.boiler_condenser_temperature_(TC3) | sensor.boiler_hptc3 |
| 1551 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr1 | compressor temperature (TR1) | short (>=-3199<=3199) | C | false | sensor.boiler_compressor_temperature_(TR1) | sensor.boiler_hptr1 |
| 1552 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr3 | refrigerant temperature liquid side (condenser output) (TR3) | short (>=-3199<=3199) | C | false | sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) | sensor.boiler_hptr3 |
| 1553 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr4 | evaporator inlet temperature (TR4) | short (>=-3199<=3199) | C | false | sensor.boiler_evaporator_inlet_temperature_(TR4) | sensor.boiler_hptr4 |
| 1554 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr5 | compressor inlet temperature (TR5) | short (>=-3199<=3199) | C | false | sensor.boiler_compressor_inlet_temperature_(TR5) | sensor.boiler_hptr5 |
| 1555 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr6 | compressor outlet temperature (TR6) | short (>=-3199<=3199) | C | false | sensor.boiler_compressor_outlet_temperature_(TR6) | sensor.boiler_hptr6 |
| 1556 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptr7 | refrigerant temperature gas side (condenser input) (TR7) | short (>=-3199<=3199) | C | false | sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7) | sensor.boiler_hptr7 |
| 1557 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hptl2 | air inlet temperature (TL2) | short (>=-3199<=3199) | C | false | sensor.boiler_air_inlet_temperature_(TL2) | sensor.boiler_hptl2 |
| 1558 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hppl1 | low pressure side temperature (PL1) | short (>=-3199<=3199) | C | false | sensor.boiler_low_pressure_side_temperature_(PL1) | sensor.boiler_hppl1 |
| 1559 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpph1 | high pressure side temperature (PH1) | short (>=-3199<=3199) | C | false | sensor.boiler_high_pressure_side_temperature_(PH1) | sensor.boiler_hpph1 |
| 1560 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | poolsettemp | pool set temperature | uint (>=0<=127) | C | true | number.boiler_pool_set_temperature | number.boiler_poolsettemp |
| 1561 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpin1opt | input 1 options | string | true | sensor.boiler_input_1_options | sensor.boiler_hpin1opt | |
| 1562 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpin2opt | input 2 options | string | true | sensor.boiler_input_2_options | sensor.boiler_hpin2opt | |
| 1563 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpin3opt | input 3 options | string | true | sensor.boiler_input_3_options | sensor.boiler_hpin3opt | |
| 1564 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpin4opt | input 4 options | string | true | sensor.boiler_input_4_options | sensor.boiler_hpin4opt | |
| 1565 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maxheatcomp | heat limit compressor | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | true | select.boiler_heat_limit_compressor | select.boiler_maxheatcomp | |
| 1566 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maxheatheat | heat limit heating | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | true | select.boiler_heat_limit_heating | select.boiler_maxheatheat | |
| 1567 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | maxheatdhw | heat limit dhw | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | true | select.boiler_heat_limit_dhw | select.boiler_maxheatdhw | |
| 1568 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | mandefrost | manual defrost | boolean | true | switch.boiler_manual_defrost | switch.boiler_mandefrost | |
| 1569 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | pvcooling | Cooling only with PV | boolean | true | switch.boiler_Cooling_only_with_PV | switch.boiler_pvcooling | |
| 1570 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheateronly | aux heater only | boolean | true | switch.boiler_aux_heater_only | switch.boiler_auxheateronly | |
| 1571 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheateroff | disable aux heater | boolean | true | switch.boiler_disable_aux_heater | switch.boiler_auxheateroff | |
| 1572 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheaterstatus | aux heater status | boolean | false | binary_sensor.boiler_aux_heater_status | binary_sensor.boiler_auxheaterstatus | |
| 1573 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheaterdelay | aux heater on delay | ushort (>=10<=1000) | K*min | true | number.boiler_aux_heater_on_delay | number.boiler_auxheaterdelay |
| 1574 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxmaxlimit | aux heater max limit | uint (>=0<=10) | K | true | number.boiler_aux_heater_max_limit | number.boiler_auxmaxlimit |
| 1575 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxlimitstart | aux heater limit start | uint (>=0<=10) | K | true | number.boiler_aux_heater_limit_start | number.boiler_auxlimitstart |
| 1576 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheatrmode | aux heater mode | enum [eco\|comfort] | true | select.boiler_aux_heater_mode | select.boiler_auxheatrmode | |
| 1577 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hphystheat | on/off hyst heat | ushort (>=50<=1500) | K*min | true | number.boiler_on/off_hyst_heat | number.boiler_hphystheat |
| 1578 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hphystcool | on/off hyst cool | ushort (>=50<=1500) | K*min | true | number.boiler_on/off_hyst_cool | number.boiler_hphystcool |
| 1579 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hphystpool | on/off hyst pool | ushort (>=50<=1500) | K*min | true | number.boiler_on/off_hyst_pool | number.boiler_hphystpool |
| 1580 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | silentmode | silent mode | enum [off\|auto\|on] | true | select.boiler_silent_mode | select.boiler_silentmode | |
| 1581 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | silentfrom | silent mode from | uint (>=0<=3810) | minutes | true | number.boiler_silent_mode_from | number.boiler_silentfrom |
| 1582 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | silentto | silent mode to | uint (>=0<=3810) | minutes | true | number.boiler_silent_mode_to | number.boiler_silentto |
| 1583 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | mintempsilent | min outside temp for silent mode | int (>=-126<=126) | C | true | number.boiler_min_outside_temp_for_silent_mode | number.boiler_mintempsilent |
| 1584 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | tempparmode | outside temp parallel mode | int (>=-126<=126) | C | true | number.boiler_outside_temp_parallel_mode | number.boiler_tempparmode |
| 1585 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | auxheatmix | aux heater mixing valve | int (>=-100<=100) | % | false | sensor.boiler_aux_heater_mixing_valve | sensor.boiler_auxheatmix |
| 1586 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | tempdiffheat | temp diff TC3/TC0 heat | uint (>=2<=10) | K | true | number.boiler_temp_diff_TC3/TC0_heat | number.boiler_tempdiffheat |
| 1587 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | tempdiffcool | temp diff TC3/TC0 cool | uint (>=2<=10) | K | true | number.boiler_temp_diff_TC3/TC0_cool | number.boiler_tempdiffcool |
| 1588 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | vpcooling | valve/pump cooling | boolean | true | switch.boiler_valve/pump_cooling | switch.boiler_vpcooling | |
| 1589 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | heatcable | heating cable | boolean | true | switch.boiler_heating_cable | switch.boiler_heatcable | |
| 1590 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | vc0valve | VC0 valve | boolean | true | switch.boiler_VC0_valve | switch.boiler_vc0valve | |
| 1591 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | primepump | primary heatpump | boolean | true | switch.boiler_primary_heatpump | switch.boiler_primepump | |
| 1592 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | primepumpmod | primary heatpump modulation | uint (>=0<=100) | % | true | number.boiler_primary_heatpump_modulation | number.boiler_primepumpmod |
| 1593 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hp3way | 3-way valve | boolean | true | switch.boiler_3-way_valve | switch.boiler_hp3way | |
| 1594 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | elheatstep1 | el. heater step 1 | boolean | true | switch.boiler_el._heater_step_1 | switch.boiler_elheatstep1 | |
| 1595 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | elheatstep2 | el. heater step 2 | boolean | true | switch.boiler_el._heater_step_2 | switch.boiler_elheatstep2 | |
| 1596 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | elheatstep3 | el. heater step 3 | boolean | true | switch.boiler_el._heater_step_3 | switch.boiler_elheatstep3 | |
| 1597 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwalternatingop | alternating operation | boolean | true | switch.boiler_alternating_operation | switch.boiler_wwalternatingop | |
| 1598 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwaltopprioheat | prioritise heating during dhw | uint (>=20<=120) | minutes | true | number.boiler_prioritise_heating_during_dhw | number.boiler_wwaltopprioheat |
| 1599 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwaltopprioww | prioritise dhw during heating | uint (>=30<=120) | minutes | true | number.boiler_prioritise_dhw_during_heating | number.boiler_wwaltopprioww |
| 1600 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcomfoff | comfort switch off | uint (>=15<=65) | C | true | number.boiler_comfort_switch_off | number.boiler_wwcomfoff |
| 1601 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwecooff | eco switch off | uint (>=15<=65) | C | true | number.boiler_eco_switch_off | number.boiler_wwecooff |
| 1602 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwecoplusoff | eco+ switch off | uint (>=48<=63) | C | true | number.boiler_eco+_switch_off | number.boiler_wwecoplusoff |
| 1603 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | hpcircpumpww | circulation pump available during dhw | boolean | true | switch.boiler_circulation_pump_available_during_dhw | switch.boiler_hpcircpumpww | |
| 1604 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 1605 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 1606 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 1607 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 1608 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 1609 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 1610 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 1611 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 1612 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 1613 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 1614 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 1615 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 1616 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 1617 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 1618 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 1619 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 1620 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 1621 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 1622 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 1623 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 1624 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 1625 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 1626 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 1627 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 1628 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 1629 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 1630 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 1631 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 1632 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 1633 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 1634 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 1635 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 1636 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 1637 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 1638 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 1639 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 1640 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 1641 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 1642 | Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i | boiler | 172 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 1643 | Geo 5xx | boiler | 173 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 1644 | Geo 5xx | boiler | 173 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 1645 | Geo 5xx | boiler | 173 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 1646 | Geo 5xx | boiler | 173 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 1647 | Geo 5xx | boiler | 173 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 1648 | Geo 5xx | boiler | 173 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 1649 | Geo 5xx | boiler | 173 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 1650 | Geo 5xx | boiler | 173 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 1651 | Geo 5xx | boiler | 173 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 1652 | Geo 5xx | boiler | 173 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 1653 | Geo 5xx | boiler | 173 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 1654 | Geo 5xx | boiler | 173 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 1655 | Geo 5xx | boiler | 173 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 1656 | Geo 5xx | boiler | 173 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 1657 | Geo 5xx | boiler | 173 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 1658 | Geo 5xx | boiler | 173 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 1659 | Geo 5xx | boiler | 173 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 1660 | Geo 5xx | boiler | 173 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 1661 | Geo 5xx | boiler | 173 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 1662 | Geo 5xx | boiler | 173 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 1663 | Geo 5xx | boiler | 173 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 1664 | Geo 5xx | boiler | 173 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 1665 | Geo 5xx | boiler | 173 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 1666 | Geo 5xx | boiler | 173 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 1667 | Geo 5xx | boiler | 173 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 1668 | Geo 5xx | boiler | 173 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 1669 | Geo 5xx | boiler | 173 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 1670 | Geo 5xx | boiler | 173 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 1671 | Geo 5xx | boiler | 173 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 1672 | Geo 5xx | boiler | 173 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 1673 | Geo 5xx | boiler | 173 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 1674 | Geo 5xx | boiler | 173 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 1675 | Geo 5xx | boiler | 173 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 1676 | Geo 5xx | boiler | 173 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 1677 | Geo 5xx | boiler | 173 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 1678 | Geo 5xx | boiler | 173 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 1679 | Geo 5xx | boiler | 173 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 1680 | Geo 5xx | boiler | 173 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 1681 | Geo 5xx | boiler | 173 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 1682 | Geo 5xx | boiler | 173 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 1683 | Geo 5xx | boiler | 173 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 1684 | Geo 5xx | boiler | 173 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 1685 | Geo 5xx | boiler | 173 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 1686 | Geo 5xx | boiler | 173 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 1687 | Geo 5xx | boiler | 173 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 1688 | Geo 5xx | boiler | 173 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 1689 | Geo 5xx | boiler | 173 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 1690 | Geo 5xx | boiler | 173 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 1691 | Geo 5xx | boiler | 173 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 1692 | Geo 5xx | boiler | 173 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 1693 | Geo 5xx | boiler | 173 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 1694 | Geo 5xx | boiler | 173 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 1695 | Geo 5xx | boiler | 173 | uptimecontrol | total operating time heat | time (>=0<=17476) | minutes | false | sensor.boiler_total_operating_time_heat | sensor.boiler_uptimecontrol |
| 1696 | Geo 5xx | boiler | 173 | uptimecompheating | operating time compressor heating | time (>=0<=17476) | minutes | false | sensor.boiler_operating_time_compressor_heating | sensor.boiler_uptimecompheating |
| 1697 | Geo 5xx | boiler | 173 | uptimecompcooling | operating time compressor cooling | time (>=0<=17476) | minutes | false | sensor.boiler_operating_time_compressor_cooling | sensor.boiler_uptimecompcooling |
| 1698 | Geo 5xx | boiler | 173 | uptimecompww | operating time compressor dhw | time (>=0<=17476) | minutes | false | sensor.boiler_operating_time_compressor_dhw | sensor.boiler_uptimecompww |
| 1699 | Geo 5xx | boiler | 173 | uptimecomppool | operating time compressor pool | time (>=0<=17476) | minutes | false | sensor.boiler_operating_time_compressor_pool | sensor.boiler_uptimecomppool |
| 1700 | Geo 5xx | boiler | 173 | totalcompstarts | total compressor control starts | ulong (>=0<=65533) | false | sensor.boiler_total_compressor_control_starts | sensor.boiler_totalcompstarts | |
| 1701 | Geo 5xx | boiler | 173 | heatingstarts | heating control starts | ulong (>=0<=65533) | false | sensor.boiler_heating_control_starts | sensor.boiler_heatingstarts | |
| 1702 | Geo 5xx | boiler | 173 | coolingstarts | cooling control starts | ulong (>=0<=65533) | false | sensor.boiler_cooling_control_starts | sensor.boiler_coolingstarts | |
| 1703 | Geo 5xx | boiler | 173 | wwstarts2 | control starts2 | ulong (>=0<=65533) | false | sensor.boiler_control_starts2 | sensor.boiler_wwstarts2 | |
| 1704 | Geo 5xx | boiler | 173 | poolstarts | pool control starts | ulong (>=0<=65533) | false | sensor.boiler_pool_control_starts | sensor.boiler_poolstarts | |
| 1705 | Geo 5xx | boiler | 173 | nrgconstotal | total energy consumption | ulong (>=0<=65533) | kWh | false | sensor.boiler_total_energy_consumption | sensor.boiler_nrgconstotal |
| 1706 | Geo 5xx | boiler | 173 | nrgconscomptotal | total energy consumption compressor | ulong (>=0<=65533) | kWh | false | sensor.boiler_total_energy_consumption_compressor | sensor.boiler_nrgconscomptotal |
| 1707 | Geo 5xx | boiler | 173 | nrgconscompheating | energy consumption compressor heating | ulong (>=0<=65533) | kWh | false | sensor.boiler_energy_consumption_compressor_heating | sensor.boiler_nrgconscompheating |
| 1708 | Geo 5xx | boiler | 173 | nrgconscompww | energy consumption compressor dhw | ulong (>=0<=65533) | kWh | false | sensor.boiler_energy_consumption_compressor_dhw | sensor.boiler_nrgconscompww |
| 1709 | Geo 5xx | boiler | 173 | nrgconscompcooling | energy consumption compressor cooling | ulong (>=0<=65533) | kWh | false | sensor.boiler_energy_consumption_compressor_cooling | sensor.boiler_nrgconscompcooling |
| 1710 | Geo 5xx | boiler | 173 | nrgconscomppool | energy consumption compressor pool | ulong (>=0<=65533) | kWh | false | sensor.boiler_energy_consumption_compressor_pool | sensor.boiler_nrgconscomppool |
| 1711 | Geo 5xx | boiler | 173 | auxelecheatnrgconstotal | total aux elec. heater energy consumption | ulong (>=0<=65533) | kWh | false | sensor.boiler_total_aux_elec._heater_energy_consumption | sensor.boiler_auxelecheatnrgconstotal |
| 1712 | Geo 5xx | boiler | 173 | auxelecheatnrgconsheating | aux elec. heater energy consumption heating | ulong (>=0<=65533) | kWh | false | sensor.boiler_aux_elec._heater_energy_consumption_heating | sensor.boiler_auxelecheatnrgconsheating |
| 1713 | Geo 5xx | boiler | 173 | auxelecheatnrgconsww | aux elec. heater energy consumption dhw | ulong (>=0<=65533) | kWh | false | sensor.boiler_aux_elec._heater_energy_consumption_dhw | sensor.boiler_auxelecheatnrgconsww |
| 1714 | Geo 5xx | boiler | 173 | auxelecheatnrgconspool | aux elec. heater energy consumption pool | ulong (>=0<=65533) | kWh | false | sensor.boiler_aux_elec._heater_energy_consumption_pool | sensor.boiler_auxelecheatnrgconspool |
| 1715 | Geo 5xx | boiler | 173 | nrgsupptotal | total energy supplied | ulong (>=0<=65533) | kWh | false | sensor.boiler_total_energy_supplied | sensor.boiler_nrgsupptotal |
| 1716 | Geo 5xx | boiler | 173 | nrgsuppheating | total energy supplied heating | ulong (>=0<=65533) | kWh | false | sensor.boiler_total_energy_supplied_heating | sensor.boiler_nrgsuppheating |
| 1717 | Geo 5xx | boiler | 173 | nrgsuppww | total energy warm supplied dhw | ulong (>=0<=65533) | kWh | false | sensor.boiler_total_energy_warm_supplied_dhw | sensor.boiler_nrgsuppww |
| 1718 | Geo 5xx | boiler | 173 | nrgsuppcooling | total energy supplied cooling | ulong (>=0<=65533) | kWh | false | sensor.boiler_total_energy_supplied_cooling | sensor.boiler_nrgsuppcooling |
| 1719 | Geo 5xx | boiler | 173 | nrgsupppool | total energy supplied pool | ulong (>=0<=65533) | kWh | false | sensor.boiler_total_energy_supplied_pool | sensor.boiler_nrgsupppool |
| 1720 | Geo 5xx | boiler | 173 | hppower | compressor power output | uint (>=0<=25) | kW | false | sensor.boiler_compressor_power_output | sensor.boiler_hppower |
| 1721 | Geo 5xx | boiler | 173 | hpcompon | hp compressor | boolean | false | binary_sensor.boiler_hp_compressor | binary_sensor.boiler_hpcompon | |
| 1722 | Geo 5xx | boiler | 173 | hpactivity | compressor activity | enum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost] | false | sensor.boiler_compressor_activity | sensor.boiler_hpactivity | |
| 1723 | Geo 5xx | boiler | 173 | hpheatingon | hp heating | boolean | false | binary_sensor.boiler_hp_heating | binary_sensor.boiler_hpheatingon | |
| 1724 | Geo 5xx | boiler | 173 | hpcoolingon | hp cooling | boolean | false | binary_sensor.boiler_hp_cooling | binary_sensor.boiler_hpcoolingon | |
| 1725 | Geo 5xx | boiler | 173 | hpwwon | hp dhw | boolean | false | binary_sensor.boiler_hp_dhw | binary_sensor.boiler_hpwwon | |
| 1726 | Geo 5xx | boiler | 173 | hppoolon | hp pool | boolean | false | binary_sensor.boiler_hp_pool | binary_sensor.boiler_hppoolon | |
| 1727 | Geo 5xx | boiler | 173 | hpbrinepumpspd | brine pump speed | uint (>=0<=100) | % | false | sensor.boiler_brine_pump_speed | sensor.boiler_hpbrinepumpspd |
| 1728 | Geo 5xx | boiler | 173 | hpswitchvalve | switch valve | boolean | false | binary_sensor.boiler_switch_valve | binary_sensor.boiler_hpswitchvalve | |
| 1729 | Geo 5xx | boiler | 173 | hpcompspd | compressor speed | uint (>=0<=100) | % | false | sensor.boiler_compressor_speed | sensor.boiler_hpcompspd |
| 1730 | Geo 5xx | boiler | 173 | hpcircspd | circulation pump speed | uint (>=0<=100) | % | false | sensor.boiler_circulation_pump_speed | sensor.boiler_hpcircspd |
| 1731 | Geo 5xx | boiler | 173 | hpbrinein | brine in/evaporator | short (>=-3199<=3199) | C | false | sensor.boiler_brine_in/evaporator | sensor.boiler_hpbrinein |
| 1732 | Geo 5xx | boiler | 173 | hpbrineout | brine out/condenser | short (>=-3199<=3199) | C | false | sensor.boiler_brine_out/condenser | sensor.boiler_hpbrineout |
| 1733 | Geo 5xx | boiler | 173 | hptc0 | heat carrier return (TC0) | short (>=-3199<=3199) | C | false | sensor.boiler_heat_carrier_return_(TC0) | sensor.boiler_hptc0 |
| 1734 | Geo 5xx | boiler | 173 | hptc1 | heat carrier forward (TC1) | short (>=-3199<=3199) | C | false | sensor.boiler_heat_carrier_forward_(TC1) | sensor.boiler_hptc1 |
| 1735 | Geo 5xx | boiler | 173 | hptc3 | condenser temperature (TC3) | short (>=-3199<=3199) | C | false | sensor.boiler_condenser_temperature_(TC3) | sensor.boiler_hptc3 |
| 1736 | Geo 5xx | boiler | 173 | hptr1 | compressor temperature (TR1) | short (>=-3199<=3199) | C | false | sensor.boiler_compressor_temperature_(TR1) | sensor.boiler_hptr1 |
| 1737 | Geo 5xx | boiler | 173 | hptr3 | refrigerant temperature liquid side (condenser output) (TR3) | short (>=-3199<=3199) | C | false | sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) | sensor.boiler_hptr3 |
| 1738 | Geo 5xx | boiler | 173 | hptr4 | evaporator inlet temperature (TR4) | short (>=-3199<=3199) | C | false | sensor.boiler_evaporator_inlet_temperature_(TR4) | sensor.boiler_hptr4 |
| 1739 | Geo 5xx | boiler | 173 | hptr5 | compressor inlet temperature (TR5) | short (>=-3199<=3199) | C | false | sensor.boiler_compressor_inlet_temperature_(TR5) | sensor.boiler_hptr5 |
| 1740 | Geo 5xx | boiler | 173 | hptr6 | compressor outlet temperature (TR6) | short (>=-3199<=3199) | C | false | sensor.boiler_compressor_outlet_temperature_(TR6) | sensor.boiler_hptr6 |
| 1741 | Geo 5xx | boiler | 173 | hptr7 | refrigerant temperature gas side (condenser input) (TR7) | short (>=-3199<=3199) | C | false | sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7) | sensor.boiler_hptr7 |
| 1742 | Geo 5xx | boiler | 173 | hptl2 | air inlet temperature (TL2) | short (>=-3199<=3199) | C | false | sensor.boiler_air_inlet_temperature_(TL2) | sensor.boiler_hptl2 |
| 1743 | Geo 5xx | boiler | 173 | hppl1 | low pressure side temperature (PL1) | short (>=-3199<=3199) | C | false | sensor.boiler_low_pressure_side_temperature_(PL1) | sensor.boiler_hppl1 |
| 1744 | Geo 5xx | boiler | 173 | hpph1 | high pressure side temperature (PH1) | short (>=-3199<=3199) | C | false | sensor.boiler_high_pressure_side_temperature_(PH1) | sensor.boiler_hpph1 |
| 1745 | Geo 5xx | boiler | 173 | poolsettemp | pool set temperature | uint (>=0<=127) | C | true | number.boiler_pool_set_temperature | number.boiler_poolsettemp |
| 1746 | Geo 5xx | boiler | 173 | hpin1opt | input 1 options | string | true | sensor.boiler_input_1_options | sensor.boiler_hpin1opt | |
| 1747 | Geo 5xx | boiler | 173 | hpin2opt | input 2 options | string | true | sensor.boiler_input_2_options | sensor.boiler_hpin2opt | |
| 1748 | Geo 5xx | boiler | 173 | hpin3opt | input 3 options | string | true | sensor.boiler_input_3_options | sensor.boiler_hpin3opt | |
| 1749 | Geo 5xx | boiler | 173 | hpin4opt | input 4 options | string | true | sensor.boiler_input_4_options | sensor.boiler_hpin4opt | |
| 1750 | Geo 5xx | boiler | 173 | maxheatcomp | heat limit compressor | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | true | select.boiler_heat_limit_compressor | select.boiler_maxheatcomp | |
| 1751 | Geo 5xx | boiler | 173 | maxheatheat | heat limit heating | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | true | select.boiler_heat_limit_heating | select.boiler_maxheatheat | |
| 1752 | Geo 5xx | boiler | 173 | maxheatdhw | heat limit dhw | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | true | select.boiler_heat_limit_dhw | select.boiler_maxheatdhw | |
| 1753 | Geo 5xx | boiler | 173 | mandefrost | manual defrost | boolean | true | switch.boiler_manual_defrost | switch.boiler_mandefrost | |
| 1754 | Geo 5xx | boiler | 173 | pvcooling | Cooling only with PV | boolean | true | switch.boiler_Cooling_only_with_PV | switch.boiler_pvcooling | |
| 1755 | Geo 5xx | boiler | 173 | auxheateronly | aux heater only | boolean | true | switch.boiler_aux_heater_only | switch.boiler_auxheateronly | |
| 1756 | Geo 5xx | boiler | 173 | auxheateroff | disable aux heater | boolean | true | switch.boiler_disable_aux_heater | switch.boiler_auxheateroff | |
| 1757 | Geo 5xx | boiler | 173 | auxheaterstatus | aux heater status | boolean | false | binary_sensor.boiler_aux_heater_status | binary_sensor.boiler_auxheaterstatus | |
| 1758 | Geo 5xx | boiler | 173 | auxheaterdelay | aux heater on delay | ushort (>=10<=1000) | K*min | true | number.boiler_aux_heater_on_delay | number.boiler_auxheaterdelay |
| 1759 | Geo 5xx | boiler | 173 | auxmaxlimit | aux heater max limit | uint (>=0<=10) | K | true | number.boiler_aux_heater_max_limit | number.boiler_auxmaxlimit |
| 1760 | Geo 5xx | boiler | 173 | auxlimitstart | aux heater limit start | uint (>=0<=10) | K | true | number.boiler_aux_heater_limit_start | number.boiler_auxlimitstart |
| 1761 | Geo 5xx | boiler | 173 | auxheatrmode | aux heater mode | enum [eco\|comfort] | true | select.boiler_aux_heater_mode | select.boiler_auxheatrmode | |
| 1762 | Geo 5xx | boiler | 173 | hphystheat | on/off hyst heat | ushort (>=50<=1500) | K*min | true | number.boiler_on/off_hyst_heat | number.boiler_hphystheat |
| 1763 | Geo 5xx | boiler | 173 | hphystcool | on/off hyst cool | ushort (>=50<=1500) | K*min | true | number.boiler_on/off_hyst_cool | number.boiler_hphystcool |
| 1764 | Geo 5xx | boiler | 173 | hphystpool | on/off hyst pool | ushort (>=50<=1500) | K*min | true | number.boiler_on/off_hyst_pool | number.boiler_hphystpool |
| 1765 | Geo 5xx | boiler | 173 | silentmode | silent mode | enum [off\|auto\|on] | true | select.boiler_silent_mode | select.boiler_silentmode | |
| 1766 | Geo 5xx | boiler | 173 | silentfrom | silent mode from | uint (>=0<=3810) | minutes | true | number.boiler_silent_mode_from | number.boiler_silentfrom |
| 1767 | Geo 5xx | boiler | 173 | silentto | silent mode to | uint (>=0<=3810) | minutes | true | number.boiler_silent_mode_to | number.boiler_silentto |
| 1768 | Geo 5xx | boiler | 173 | mintempsilent | min outside temp for silent mode | int (>=-126<=126) | C | true | number.boiler_min_outside_temp_for_silent_mode | number.boiler_mintempsilent |
| 1769 | Geo 5xx | boiler | 173 | tempparmode | outside temp parallel mode | int (>=-126<=126) | C | true | number.boiler_outside_temp_parallel_mode | number.boiler_tempparmode |
| 1770 | Geo 5xx | boiler | 173 | auxheatmix | aux heater mixing valve | int (>=-100<=100) | % | false | sensor.boiler_aux_heater_mixing_valve | sensor.boiler_auxheatmix |
| 1771 | Geo 5xx | boiler | 173 | tempdiffheat | temp diff TC3/TC0 heat | uint (>=2<=10) | K | true | number.boiler_temp_diff_TC3/TC0_heat | number.boiler_tempdiffheat |
| 1772 | Geo 5xx | boiler | 173 | tempdiffcool | temp diff TC3/TC0 cool | uint (>=2<=10) | K | true | number.boiler_temp_diff_TC3/TC0_cool | number.boiler_tempdiffcool |
| 1773 | Geo 5xx | boiler | 173 | vpcooling | valve/pump cooling | boolean | true | switch.boiler_valve/pump_cooling | switch.boiler_vpcooling | |
| 1774 | Geo 5xx | boiler | 173 | heatcable | heating cable | boolean | true | switch.boiler_heating_cable | switch.boiler_heatcable | |
| 1775 | Geo 5xx | boiler | 173 | vc0valve | VC0 valve | boolean | true | switch.boiler_VC0_valve | switch.boiler_vc0valve | |
| 1776 | Geo 5xx | boiler | 173 | primepump | primary heatpump | boolean | true | switch.boiler_primary_heatpump | switch.boiler_primepump | |
| 1777 | Geo 5xx | boiler | 173 | primepumpmod | primary heatpump modulation | uint (>=0<=100) | % | true | number.boiler_primary_heatpump_modulation | number.boiler_primepumpmod |
| 1778 | Geo 5xx | boiler | 173 | hp3way | 3-way valve | boolean | true | switch.boiler_3-way_valve | switch.boiler_hp3way | |
| 1779 | Geo 5xx | boiler | 173 | elheatstep1 | el. heater step 1 | boolean | true | switch.boiler_el._heater_step_1 | switch.boiler_elheatstep1 | |
| 1780 | Geo 5xx | boiler | 173 | elheatstep2 | el. heater step 2 | boolean | true | switch.boiler_el._heater_step_2 | switch.boiler_elheatstep2 | |
| 1781 | Geo 5xx | boiler | 173 | elheatstep3 | el. heater step 3 | boolean | true | switch.boiler_el._heater_step_3 | switch.boiler_elheatstep3 | |
| 1782 | Geo 5xx | boiler | 173 | wwalternatingop | alternating operation | boolean | true | switch.boiler_alternating_operation | switch.boiler_wwalternatingop | |
| 1783 | Geo 5xx | boiler | 173 | wwaltopprioheat | prioritise heating during dhw | uint (>=20<=120) | minutes | true | number.boiler_prioritise_heating_during_dhw | number.boiler_wwaltopprioheat |
| 1784 | Geo 5xx | boiler | 173 | wwaltopprioww | prioritise dhw during heating | uint (>=30<=120) | minutes | true | number.boiler_prioritise_dhw_during_heating | number.boiler_wwaltopprioww |
| 1785 | Geo 5xx | boiler | 173 | wwcomfoff | comfort switch off | uint (>=15<=65) | C | true | number.boiler_comfort_switch_off | number.boiler_wwcomfoff |
| 1786 | Geo 5xx | boiler | 173 | wwecooff | eco switch off | uint (>=15<=65) | C | true | number.boiler_eco_switch_off | number.boiler_wwecooff |
| 1787 | Geo 5xx | boiler | 173 | wwecoplusoff | eco+ switch off | uint (>=48<=63) | C | true | number.boiler_eco+_switch_off | number.boiler_wwecoplusoff |
| 1788 | Geo 5xx | boiler | 173 | hpcircpumpww | circulation pump available during dhw | boolean | true | switch.boiler_circulation_pump_available_during_dhw | switch.boiler_hpcircpumpww | |
| 1789 | Geo 5xx | boiler | 173 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 1790 | Geo 5xx | boiler | 173 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 1791 | Geo 5xx | boiler | 173 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 1792 | Geo 5xx | boiler | 173 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 1793 | Geo 5xx | boiler | 173 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 1794 | Geo 5xx | boiler | 173 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 1795 | Geo 5xx | boiler | 173 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 1796 | Geo 5xx | boiler | 173 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 1797 | Geo 5xx | boiler | 173 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 1798 | Geo 5xx | boiler | 173 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 1799 | Geo 5xx | boiler | 173 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 1800 | Geo 5xx | boiler | 173 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 1801 | Geo 5xx | boiler | 173 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 1802 | Geo 5xx | boiler | 173 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 1803 | Geo 5xx | boiler | 173 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 1804 | Geo 5xx | boiler | 173 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 1805 | Geo 5xx | boiler | 173 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 1806 | Geo 5xx | boiler | 173 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 1807 | Geo 5xx | boiler | 173 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 1808 | Geo 5xx | boiler | 173 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 1809 | Geo 5xx | boiler | 173 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 1810 | Geo 5xx | boiler | 173 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 1811 | Geo 5xx | boiler | 173 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 1812 | Geo 5xx | boiler | 173 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 1813 | Geo 5xx | boiler | 173 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 1814 | Geo 5xx | boiler | 173 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 1815 | Geo 5xx | boiler | 173 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 1816 | Geo 5xx | boiler | 173 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 1817 | Geo 5xx | boiler | 173 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 1818 | Geo 5xx | boiler | 173 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 1819 | Geo 5xx | boiler | 173 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 1820 | Geo 5xx | boiler | 173 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 1821 | Geo 5xx | boiler | 173 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 1822 | Geo 5xx | boiler | 173 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 1823 | Geo 5xx | boiler | 173 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 1824 | Geo 5xx | boiler | 173 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 1825 | Geo 5xx | boiler | 173 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 1826 | Geo 5xx | boiler | 173 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 1827 | Geo 5xx | boiler | 173 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 1828 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 1829 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 1830 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 1831 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 1832 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 1833 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 1834 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 1835 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 1836 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 1837 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 1838 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 1839 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 1840 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 1841 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 1842 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 1843 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 1844 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 1845 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 1846 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 1847 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 1848 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 1849 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 1850 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 1851 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 1852 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 1853 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 1854 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 1855 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 1856 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 1857 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 1858 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 1859 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 1860 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 1861 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 1862 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 1863 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 1864 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 1865 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 1866 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 1867 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 1868 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 1869 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 1870 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 1871 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 1872 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 1873 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 1874 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 1875 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 1876 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 1877 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 1878 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 1879 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 1880 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 1881 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 1882 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 1883 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 1884 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 1885 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 1886 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 1887 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 1888 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 1889 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 1890 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 1891 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 1892 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 1893 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 1894 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 1895 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 1896 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 1897 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 1898 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 1899 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 1900 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 1901 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 1902 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 1903 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 1904 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 1905 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 1906 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 1907 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 1908 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 1909 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 1910 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 1911 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 1912 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 1913 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 1914 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 1915 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 1916 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 1917 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 1918 | Condens 5000i/Greenstar 8000/GC9800IW | boiler | 195 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 1919 | Logamax U122/Cerapur | boiler | 203 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 1920 | Logamax U122/Cerapur | boiler | 203 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 1921 | Logamax U122/Cerapur | boiler | 203 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 1922 | Logamax U122/Cerapur | boiler | 203 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 1923 | Logamax U122/Cerapur | boiler | 203 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 1924 | Logamax U122/Cerapur | boiler | 203 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 1925 | Logamax U122/Cerapur | boiler | 203 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 1926 | Logamax U122/Cerapur | boiler | 203 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 1927 | Logamax U122/Cerapur | boiler | 203 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 1928 | Logamax U122/Cerapur | boiler | 203 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 1929 | Logamax U122/Cerapur | boiler | 203 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 1930 | Logamax U122/Cerapur | boiler | 203 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 1931 | Logamax U122/Cerapur | boiler | 203 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 1932 | Logamax U122/Cerapur | boiler | 203 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 1933 | Logamax U122/Cerapur | boiler | 203 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 1934 | Logamax U122/Cerapur | boiler | 203 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 1935 | Logamax U122/Cerapur | boiler | 203 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 1936 | Logamax U122/Cerapur | boiler | 203 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 1937 | Logamax U122/Cerapur | boiler | 203 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 1938 | Logamax U122/Cerapur | boiler | 203 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 1939 | Logamax U122/Cerapur | boiler | 203 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 1940 | Logamax U122/Cerapur | boiler | 203 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 1941 | Logamax U122/Cerapur | boiler | 203 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 1942 | Logamax U122/Cerapur | boiler | 203 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 1943 | Logamax U122/Cerapur | boiler | 203 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 1944 | Logamax U122/Cerapur | boiler | 203 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 1945 | Logamax U122/Cerapur | boiler | 203 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 1946 | Logamax U122/Cerapur | boiler | 203 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 1947 | Logamax U122/Cerapur | boiler | 203 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 1948 | Logamax U122/Cerapur | boiler | 203 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 1949 | Logamax U122/Cerapur | boiler | 203 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 1950 | Logamax U122/Cerapur | boiler | 203 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 1951 | Logamax U122/Cerapur | boiler | 203 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 1952 | Logamax U122/Cerapur | boiler | 203 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 1953 | Logamax U122/Cerapur | boiler | 203 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 1954 | Logamax U122/Cerapur | boiler | 203 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 1955 | Logamax U122/Cerapur | boiler | 203 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 1956 | Logamax U122/Cerapur | boiler | 203 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 1957 | Logamax U122/Cerapur | boiler | 203 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 1958 | Logamax U122/Cerapur | boiler | 203 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 1959 | Logamax U122/Cerapur | boiler | 203 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 1960 | Logamax U122/Cerapur | boiler | 203 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 1961 | Logamax U122/Cerapur | boiler | 203 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 1962 | Logamax U122/Cerapur | boiler | 203 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 1963 | Logamax U122/Cerapur | boiler | 203 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 1964 | Logamax U122/Cerapur | boiler | 203 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 1965 | Logamax U122/Cerapur | boiler | 203 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 1966 | Logamax U122/Cerapur | boiler | 203 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 1967 | Logamax U122/Cerapur | boiler | 203 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 1968 | Logamax U122/Cerapur | boiler | 203 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 1969 | Logamax U122/Cerapur | boiler | 203 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 1970 | Logamax U122/Cerapur | boiler | 203 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 1971 | Logamax U122/Cerapur | boiler | 203 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 1972 | Logamax U122/Cerapur | boiler | 203 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 1973 | Logamax U122/Cerapur | boiler | 203 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 1974 | Logamax U122/Cerapur | boiler | 203 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 1975 | Logamax U122/Cerapur | boiler | 203 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 1976 | Logamax U122/Cerapur | boiler | 203 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 1977 | Logamax U122/Cerapur | boiler | 203 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 1978 | Logamax U122/Cerapur | boiler | 203 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 1979 | Logamax U122/Cerapur | boiler | 203 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 1980 | Logamax U122/Cerapur | boiler | 203 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 1981 | Logamax U122/Cerapur | boiler | 203 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 1982 | Logamax U122/Cerapur | boiler | 203 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 1983 | Logamax U122/Cerapur | boiler | 203 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 1984 | Logamax U122/Cerapur | boiler | 203 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 1985 | Logamax U122/Cerapur | boiler | 203 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 1986 | Logamax U122/Cerapur | boiler | 203 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 1987 | Logamax U122/Cerapur | boiler | 203 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 1988 | Logamax U122/Cerapur | boiler | 203 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 1989 | Logamax U122/Cerapur | boiler | 203 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 1990 | Logamax U122/Cerapur | boiler | 203 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 1991 | Logamax U122/Cerapur | boiler | 203 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 1992 | Logamax U122/Cerapur | boiler | 203 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 1993 | Logamax U122/Cerapur | boiler | 203 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 1994 | Logamax U122/Cerapur | boiler | 203 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 1995 | Logamax U122/Cerapur | boiler | 203 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 1996 | Logamax U122/Cerapur | boiler | 203 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 1997 | Logamax U122/Cerapur | boiler | 203 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 1998 | Logamax U122/Cerapur | boiler | 203 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 1999 | Logamax U122/Cerapur | boiler | 203 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 2000 | Logamax U122/Cerapur | boiler | 203 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 2001 | Logamax U122/Cerapur | boiler | 203 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 2002 | Logamax U122/Cerapur | boiler | 203 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 2003 | Logamax U122/Cerapur | boiler | 203 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 2004 | Logamax U122/Cerapur | boiler | 203 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 2005 | Logamax U122/Cerapur | boiler | 203 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 2006 | Logamax U122/Cerapur | boiler | 203 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 2007 | Logamax U122/Cerapur | boiler | 203 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 2008 | Logamax U122/Cerapur | boiler | 203 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 2009 | Logamax U122/Cerapur | boiler | 203 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 2010 | Ecomline Excellent | boiler | 206 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 2011 | Ecomline Excellent | boiler | 206 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 2012 | Ecomline Excellent | boiler | 206 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 2013 | Ecomline Excellent | boiler | 206 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 2014 | Ecomline Excellent | boiler | 206 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 2015 | Ecomline Excellent | boiler | 206 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 2016 | Ecomline Excellent | boiler | 206 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 2017 | Ecomline Excellent | boiler | 206 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 2018 | Ecomline Excellent | boiler | 206 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 2019 | Ecomline Excellent | boiler | 206 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 2020 | Ecomline Excellent | boiler | 206 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 2021 | Ecomline Excellent | boiler | 206 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 2022 | Ecomline Excellent | boiler | 206 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 2023 | Ecomline Excellent | boiler | 206 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 2024 | Ecomline Excellent | boiler | 206 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 2025 | Ecomline Excellent | boiler | 206 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 2026 | Ecomline Excellent | boiler | 206 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 2027 | Ecomline Excellent | boiler | 206 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 2028 | Ecomline Excellent | boiler | 206 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 2029 | Ecomline Excellent | boiler | 206 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 2030 | Ecomline Excellent | boiler | 206 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 2031 | Ecomline Excellent | boiler | 206 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 2032 | Ecomline Excellent | boiler | 206 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 2033 | Ecomline Excellent | boiler | 206 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 2034 | Ecomline Excellent | boiler | 206 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 2035 | Ecomline Excellent | boiler | 206 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 2036 | Ecomline Excellent | boiler | 206 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 2037 | Ecomline Excellent | boiler | 206 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 2038 | Ecomline Excellent | boiler | 206 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 2039 | Ecomline Excellent | boiler | 206 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 2040 | Ecomline Excellent | boiler | 206 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 2041 | Ecomline Excellent | boiler | 206 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 2042 | Ecomline Excellent | boiler | 206 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 2043 | Ecomline Excellent | boiler | 206 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 2044 | Ecomline Excellent | boiler | 206 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 2045 | Ecomline Excellent | boiler | 206 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 2046 | Ecomline Excellent | boiler | 206 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 2047 | Ecomline Excellent | boiler | 206 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 2048 | Ecomline Excellent | boiler | 206 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 2049 | Ecomline Excellent | boiler | 206 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 2050 | Ecomline Excellent | boiler | 206 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 2051 | Ecomline Excellent | boiler | 206 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 2052 | Ecomline Excellent | boiler | 206 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 2053 | Ecomline Excellent | boiler | 206 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 2054 | Ecomline Excellent | boiler | 206 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 2055 | Ecomline Excellent | boiler | 206 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 2056 | Ecomline Excellent | boiler | 206 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 2057 | Ecomline Excellent | boiler | 206 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 2058 | Ecomline Excellent | boiler | 206 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 2059 | Ecomline Excellent | boiler | 206 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 2060 | Ecomline Excellent | boiler | 206 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 2061 | Ecomline Excellent | boiler | 206 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 2062 | Ecomline Excellent | boiler | 206 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 2063 | Ecomline Excellent | boiler | 206 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 2064 | Ecomline Excellent | boiler | 206 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 2065 | Ecomline Excellent | boiler | 206 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 2066 | Ecomline Excellent | boiler | 206 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 2067 | Ecomline Excellent | boiler | 206 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 2068 | Ecomline Excellent | boiler | 206 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 2069 | Ecomline Excellent | boiler | 206 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 2070 | Ecomline Excellent | boiler | 206 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 2071 | Ecomline Excellent | boiler | 206 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 2072 | Ecomline Excellent | boiler | 206 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 2073 | Ecomline Excellent | boiler | 206 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 2074 | Ecomline Excellent | boiler | 206 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 2075 | Ecomline Excellent | boiler | 206 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 2076 | Ecomline Excellent | boiler | 206 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 2077 | Ecomline Excellent | boiler | 206 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 2078 | Ecomline Excellent | boiler | 206 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 2079 | Ecomline Excellent | boiler | 206 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 2080 | Ecomline Excellent | boiler | 206 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 2081 | Ecomline Excellent | boiler | 206 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 2082 | Ecomline Excellent | boiler | 206 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 2083 | Ecomline Excellent | boiler | 206 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 2084 | Ecomline Excellent | boiler | 206 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 2085 | Ecomline Excellent | boiler | 206 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 2086 | Ecomline Excellent | boiler | 206 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 2087 | Ecomline Excellent | boiler | 206 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 2088 | Ecomline Excellent | boiler | 206 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 2089 | Ecomline Excellent | boiler | 206 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 2090 | Ecomline Excellent | boiler | 206 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 2091 | Ecomline Excellent | boiler | 206 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 2092 | Ecomline Excellent | boiler | 206 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 2093 | Ecomline Excellent | boiler | 206 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 2094 | Ecomline Excellent | boiler | 206 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 2095 | Ecomline Excellent | boiler | 206 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 2096 | Ecomline Excellent | boiler | 206 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 2097 | Ecomline Excellent | boiler | 206 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 2098 | Ecomline Excellent | boiler | 206 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 2099 | Ecomline Excellent | boiler | 206 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 2100 | Ecomline Excellent | boiler | 206 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 2101 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 2102 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 2103 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 2104 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 2105 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 2106 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 2107 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 2108 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 2109 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 2110 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 2111 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 2112 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 2113 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 2114 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 2115 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 2116 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 2117 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 2118 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 2119 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 2120 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 2121 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 2122 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 2123 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 2124 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 2125 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 2126 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 2127 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 2128 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 2129 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 2130 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 2131 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 2132 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 2133 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 2134 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 2135 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 2136 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 2137 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 2138 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 2139 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 2140 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 2141 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 2142 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 2143 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 2144 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 2145 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 2146 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 2147 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 2148 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 2149 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 2150 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 2151 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 2152 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 2153 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 2154 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 2155 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 2156 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 2157 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 2158 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 2159 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 2160 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 2161 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 2162 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 2163 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 2164 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 2165 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 2166 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 2167 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 2168 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 2169 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 2170 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 2171 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 2172 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 2173 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 2174 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 2175 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 2176 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 2177 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 2178 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 2179 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 2180 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 2181 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 2182 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 2183 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 2184 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 2185 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 2186 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 2187 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 2188 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 2189 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 2190 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 2191 | Logamax Plus/GB192/Condens GC9000/Greenstar ErP | boiler | 208 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 2192 | Cascade MC400 | boiler | 210 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 2193 | Cascade MC400 | boiler | 210 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 2194 | Cascade MC400 | boiler | 210 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 2195 | Cascade MC400 | boiler | 210 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 2196 | Cascade MC400 | boiler | 210 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 2197 | Cascade MC400 | boiler | 210 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 2198 | Cascade MC400 | boiler | 210 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 2199 | Cascade MC400 | boiler | 210 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 2200 | Cascade MC400 | boiler | 210 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 2201 | Cascade MC400 | boiler | 210 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 2202 | Cascade MC400 | boiler | 210 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 2203 | Cascade MC400 | boiler | 210 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 2204 | Cascade MC400 | boiler | 210 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 2205 | Cascade MC400 | boiler | 210 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 2206 | Cascade MC400 | boiler | 210 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 2207 | Cascade MC400 | boiler | 210 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 2208 | Cascade MC400 | boiler | 210 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 2209 | Cascade MC400 | boiler | 210 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 2210 | Cascade MC400 | boiler | 210 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 2211 | Cascade MC400 | boiler | 210 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 2212 | Cascade MC400 | boiler | 210 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 2213 | Cascade MC400 | boiler | 210 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 2214 | Cascade MC400 | boiler | 210 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 2215 | Cascade MC400 | boiler | 210 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 2216 | Cascade MC400 | boiler | 210 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 2217 | Cascade MC400 | boiler | 210 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 2218 | Cascade MC400 | boiler | 210 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 2219 | Cascade MC400 | boiler | 210 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 2220 | Cascade MC400 | boiler | 210 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 2221 | Cascade MC400 | boiler | 210 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 2222 | Cascade MC400 | boiler | 210 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 2223 | Cascade MC400 | boiler | 210 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 2224 | Cascade MC400 | boiler | 210 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 2225 | Cascade MC400 | boiler | 210 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 2226 | Cascade MC400 | boiler | 210 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 2227 | Cascade MC400 | boiler | 210 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 2228 | Cascade MC400 | boiler | 210 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 2229 | Cascade MC400 | boiler | 210 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 2230 | Cascade MC400 | boiler | 210 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 2231 | Cascade MC400 | boiler | 210 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 2232 | Cascade MC400 | boiler | 210 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 2233 | Cascade MC400 | boiler | 210 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 2234 | Cascade MC400 | boiler | 210 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 2235 | Cascade MC400 | boiler | 210 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 2236 | Cascade MC400 | boiler | 210 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 2237 | Cascade MC400 | boiler | 210 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 2238 | Cascade MC400 | boiler | 210 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 2239 | Cascade MC400 | boiler | 210 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 2240 | Cascade MC400 | boiler | 210 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 2241 | Cascade MC400 | boiler | 210 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 2242 | Cascade MC400 | boiler | 210 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 2243 | Cascade MC400 | boiler | 210 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 2244 | Cascade MC400 | boiler | 210 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 2245 | Cascade MC400 | boiler | 210 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 2246 | Cascade MC400 | boiler | 210 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 2247 | Cascade MC400 | boiler | 210 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 2248 | Cascade MC400 | boiler | 210 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 2249 | Cascade MC400 | boiler | 210 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 2250 | Cascade MC400 | boiler | 210 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 2251 | Cascade MC400 | boiler | 210 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 2252 | Cascade MC400 | boiler | 210 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 2253 | Cascade MC400 | boiler | 210 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 2254 | Cascade MC400 | boiler | 210 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 2255 | Cascade MC400 | boiler | 210 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 2256 | Cascade MC400 | boiler | 210 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 2257 | Cascade MC400 | boiler | 210 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 2258 | Cascade MC400 | boiler | 210 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 2259 | Cascade MC400 | boiler | 210 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 2260 | Cascade MC400 | boiler | 210 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 2261 | Cascade MC400 | boiler | 210 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 2262 | Cascade MC400 | boiler | 210 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 2263 | Cascade MC400 | boiler | 210 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 2264 | Cascade MC400 | boiler | 210 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 2265 | Cascade MC400 | boiler | 210 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 2266 | Cascade MC400 | boiler | 210 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 2267 | Cascade MC400 | boiler | 210 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 2268 | Cascade MC400 | boiler | 210 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 2269 | Cascade MC400 | boiler | 210 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 2270 | Cascade MC400 | boiler | 210 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 2271 | Cascade MC400 | boiler | 210 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 2272 | Cascade MC400 | boiler | 210 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 2273 | Cascade MC400 | boiler | 210 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 2274 | Cascade MC400 | boiler | 210 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 2275 | Cascade MC400 | boiler | 210 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 2276 | Cascade MC400 | boiler | 210 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 2277 | Cascade MC400 | boiler | 210 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 2278 | Cascade MC400 | boiler | 210 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 2279 | Cascade MC400 | boiler | 210 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 2280 | Cascade MC400 | boiler | 210 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 2281 | Cascade MC400 | boiler | 210 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 2282 | Cascade MC400 | boiler | 210 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 2283 | EasyControl Adapter | boiler | 211 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 2284 | EasyControl Adapter | boiler | 211 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 2285 | EasyControl Adapter | boiler | 211 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 2286 | EasyControl Adapter | boiler | 211 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 2287 | EasyControl Adapter | boiler | 211 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 2288 | EasyControl Adapter | boiler | 211 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 2289 | EasyControl Adapter | boiler | 211 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 2290 | EasyControl Adapter | boiler | 211 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 2291 | EasyControl Adapter | boiler | 211 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 2292 | EasyControl Adapter | boiler | 211 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 2293 | EasyControl Adapter | boiler | 211 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 2294 | EasyControl Adapter | boiler | 211 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 2295 | EasyControl Adapter | boiler | 211 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 2296 | EasyControl Adapter | boiler | 211 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 2297 | EasyControl Adapter | boiler | 211 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 2298 | EasyControl Adapter | boiler | 211 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 2299 | EasyControl Adapter | boiler | 211 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 2300 | EasyControl Adapter | boiler | 211 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 2301 | EasyControl Adapter | boiler | 211 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 2302 | EasyControl Adapter | boiler | 211 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 2303 | EasyControl Adapter | boiler | 211 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 2304 | EasyControl Adapter | boiler | 211 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 2305 | EasyControl Adapter | boiler | 211 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 2306 | EasyControl Adapter | boiler | 211 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 2307 | EasyControl Adapter | boiler | 211 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 2308 | EasyControl Adapter | boiler | 211 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 2309 | EasyControl Adapter | boiler | 211 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 2310 | EasyControl Adapter | boiler | 211 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 2311 | EasyControl Adapter | boiler | 211 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 2312 | EasyControl Adapter | boiler | 211 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 2313 | EasyControl Adapter | boiler | 211 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 2314 | EasyControl Adapter | boiler | 211 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 2315 | EasyControl Adapter | boiler | 211 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 2316 | EasyControl Adapter | boiler | 211 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 2317 | EasyControl Adapter | boiler | 211 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 2318 | EasyControl Adapter | boiler | 211 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 2319 | EasyControl Adapter | boiler | 211 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 2320 | EasyControl Adapter | boiler | 211 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 2321 | EasyControl Adapter | boiler | 211 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 2322 | EasyControl Adapter | boiler | 211 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 2323 | EasyControl Adapter | boiler | 211 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 2324 | EasyControl Adapter | boiler | 211 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 2325 | EasyControl Adapter | boiler | 211 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 2326 | EasyControl Adapter | boiler | 211 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 2327 | EasyControl Adapter | boiler | 211 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 2328 | EasyControl Adapter | boiler | 211 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 2329 | EasyControl Adapter | boiler | 211 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 2330 | EasyControl Adapter | boiler | 211 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 2331 | EasyControl Adapter | boiler | 211 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 2332 | EasyControl Adapter | boiler | 211 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 2333 | EasyControl Adapter | boiler | 211 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 2334 | EasyControl Adapter | boiler | 211 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 2335 | EasyControl Adapter | boiler | 211 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 2336 | EasyControl Adapter | boiler | 211 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 2337 | EasyControl Adapter | boiler | 211 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 2338 | EasyControl Adapter | boiler | 211 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 2339 | EasyControl Adapter | boiler | 211 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 2340 | EasyControl Adapter | boiler | 211 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 2341 | EasyControl Adapter | boiler | 211 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 2342 | EasyControl Adapter | boiler | 211 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 2343 | EasyControl Adapter | boiler | 211 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 2344 | EasyControl Adapter | boiler | 211 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 2345 | EasyControl Adapter | boiler | 211 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 2346 | EasyControl Adapter | boiler | 211 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 2347 | EasyControl Adapter | boiler | 211 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 2348 | EasyControl Adapter | boiler | 211 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 2349 | EasyControl Adapter | boiler | 211 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 2350 | EasyControl Adapter | boiler | 211 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 2351 | EasyControl Adapter | boiler | 211 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 2352 | EasyControl Adapter | boiler | 211 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 2353 | EasyControl Adapter | boiler | 211 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 2354 | EasyControl Adapter | boiler | 211 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 2355 | EasyControl Adapter | boiler | 211 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 2356 | EasyControl Adapter | boiler | 211 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 2357 | EasyControl Adapter | boiler | 211 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 2358 | EasyControl Adapter | boiler | 211 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 2359 | EasyControl Adapter | boiler | 211 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 2360 | EasyControl Adapter | boiler | 211 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 2361 | EasyControl Adapter | boiler | 211 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 2362 | EasyControl Adapter | boiler | 211 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 2363 | EasyControl Adapter | boiler | 211 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 2364 | EasyControl Adapter | boiler | 211 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 2365 | EasyControl Adapter | boiler | 211 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 2366 | EasyControl Adapter | boiler | 211 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 2367 | EasyControl Adapter | boiler | 211 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 2368 | EasyControl Adapter | boiler | 211 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 2369 | EasyControl Adapter | boiler | 211 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 2370 | EasyControl Adapter | boiler | 211 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 2371 | EasyControl Adapter | boiler | 211 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 2372 | EasyControl Adapter | boiler | 211 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 2373 | EasyControl Adapter | boiler | 211 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 2374 | Greenstar HIU | boiler | 219 | keepwarmtemp | keep warm temperature | uint (>=0<=254) | C | true | number.boiler_keep_warm_temperature | number.boiler_keepwarmtemp |
| 2375 | Greenstar HIU | boiler | 219 | setreturntemp | set temp return | uint (>=0<=254) | C | true | number.boiler_set_temp_return | number.boiler_setreturntemp |
| 2376 | Greenstar HIU | boiler | 219 | cwflowrate | cold water flow rate | ushort (>=0<=31999) | l/min | false | sensor.boiler_cold_water_flow_rate | sensor.boiler_cwflowrate |
| 2377 | Greenstar HIU | boiler | 219 | netflowtemp | heat network flow temp | ushort (>=0<=31999) | C | false | sensor.boiler_heat_network_flow_temp | sensor.boiler_netflowtemp |
| 2378 | Greenstar HIU | boiler | 219 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 2379 | Greenstar HIU | boiler | 219 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 2380 | Greenstar HIU | boiler | 219 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 2381 | Greenstar HIU | boiler | 219 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 2382 | Greenstar HIU | boiler | 219 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 2383 | Greenstar HIU | boiler | 219 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 2384 | Greenstar HIU | boiler | 219 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 2385 | Greenstar HIU | boiler | 219 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 2386 | Greenstar HIU | boiler | 219 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 2387 | Greenstar HIU | boiler | 219 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 2388 | Greenstar HIU | boiler | 219 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 2389 | Greenstar HIU | boiler | 219 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 2390 | Greenstar HIU | boiler | 219 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 2391 | Greenstar HIU | boiler | 219 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 2392 | Greenstar HIU | boiler | 219 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 2393 | Greenstar HIU | boiler | 219 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 2394 | Greenstar HIU | boiler | 219 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 2395 | Greenstar HIU | boiler | 219 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 2396 | Greenstar HIU | boiler | 219 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 2397 | Greenstar HIU | boiler | 219 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 2398 | Greenstar HIU | boiler | 219 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 2399 | Greenstar HIU | boiler | 219 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 2400 | Greenstar HIU | boiler | 219 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 2401 | Greenstar HIU | boiler | 219 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 2402 | Greenstar HIU | boiler | 219 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 2403 | Greenstar HIU | boiler | 219 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 2404 | Greenstar HIU | boiler | 219 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 2405 | Greenstar HIU | boiler | 219 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 2406 | Greenstar HIU | boiler | 219 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 2407 | Greenstar HIU | boiler | 219 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 2408 | Greenstar HIU | boiler | 219 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 2409 | Greenstar HIU | boiler | 219 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| 2410 | Greenstar HIU | boiler | 219 | setflowtemp | set flow temperature | uint (>=0<=254) | C | false | sensor.boiler_set_flow_temperature | sensor.boiler_setflowtemp |
| 2411 | Greenstar HIU | boiler | 219 | setburnpow | burner set power | uint (>=0<=100) | % | false | sensor.boiler_burner_set_power | sensor.boiler_setburnpow |
| 2412 | Greenstar HIU | boiler | 219 | absburnpow | burner current power (absolute) | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power_(absolute) | sensor.boiler_absburnpow |
| 2413 | Greenstar HIU | boiler | 219 | selburnpow | burner selected max power | uint (>=0<=254) | % | true | number.boiler_burner_selected_max_power | number.boiler_selburnpow |
| 2414 | Greenstar HIU | boiler | 219 | curburnpow | burner current power | uint (>=0<=100) | % | false | sensor.boiler_burner_current_power | sensor.boiler_curburnpow |
| 2415 | Greenstar HIU | boiler | 219 | burnstarts | burner starts | ulong (>=0<=65533) | false | sensor.boiler_burner_starts | sensor.boiler_burnstarts | |
| 2416 | Greenstar HIU | boiler | 219 | burnworkmin | total burner operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_burner_operating_time | sensor.boiler_burnworkmin |
| 2417 | Greenstar HIU | boiler | 219 | burn2workmin | burner stage 2 operating time | time (>=0<=65533) | minutes | false | sensor.boiler_burner_stage_2_operating_time | sensor.boiler_burn2workmin |
| 2418 | Greenstar HIU | boiler | 219 | heatworkmin | total heat operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_heat_operating_time | sensor.boiler_heatworkmin |
| 2419 | Greenstar HIU | boiler | 219 | heatstarts | burner starts heating | ulong (>=0<=65533) | false | sensor.boiler_burner_starts_heating | sensor.boiler_heatstarts | |
| 2420 | Greenstar HIU | boiler | 219 | ubauptime | total UBA operating time | time (>=0<=65533) | minutes | false | sensor.boiler_total_UBA_operating_time | sensor.boiler_ubauptime |
| 2421 | Greenstar HIU | boiler | 219 | lastcode | last error code | string | false | sensor.boiler_last_error_code | sensor.boiler_lastcode | |
| 2422 | Greenstar HIU | boiler | 219 | servicecode | service code | string | false | sensor.boiler_service_code | sensor.boiler_servicecode | |
| 2423 | Greenstar HIU | boiler | 219 | servicecodenumber | service code number | ushort (>=0<=31999) | false | sensor.boiler_service_code_number | sensor.boiler_servicecodenumber | |
| 2424 | Greenstar HIU | boiler | 219 | maintenancemessage | maintenance message | string | false | sensor.boiler_maintenance_message | sensor.boiler_maintenancemessage | |
| 2425 | Greenstar HIU | boiler | 219 | maintenance | maintenance scheduled | enum [off\|time\|date\|manual] | true | select.boiler_maintenance_scheduled | select.boiler_maintenance | |
| 2426 | Greenstar HIU | boiler | 219 | maintenancetime | time to next maintenance | ushort (>=0<=31999) | hours | true | number.boiler_time_to_next_maintenance | number.boiler_maintenancetime |
| 2427 | Greenstar HIU | boiler | 219 | maintenancedate | next maintenance date | string | true | sensor.boiler_next_maintenance_date | sensor.boiler_maintenancedate | |
| 2428 | Greenstar HIU | boiler | 219 | emergencyops | emergency operation | boolean | true | switch.boiler_emergency_operation | switch.boiler_emergencyops | |
| 2429 | Greenstar HIU | boiler | 219 | emergencytemp | emergency temperature | uint (>=15<=70) | C | true | number.boiler_emergency_temperature | number.boiler_emergencytemp |
| 2430 | Greenstar HIU | boiler | 219 | wwtapactivated | turn on/off | boolean | true | switch.boiler_turn_on/off | switch.boiler_wwtapactivated | |
| 2431 | Greenstar HIU | boiler | 219 | wwsettemp | set temperature | uint (>=0<=254) | C | false | sensor.boiler_set_temperature | sensor.boiler_wwsettemp |
| 2432 | Greenstar HIU | boiler | 219 | wwseltemp | selected temperature | uint (>=0<=254) | C | true | number.boiler_selected_temperature | number.boiler_wwseltemp |
| 2433 | Greenstar HIU | boiler | 219 | wwseltemplow | selected lower temperature | uint (>=0<=254) | C | true | number.boiler_selected_lower_temperature | number.boiler_wwseltemplow |
| 2434 | Greenstar HIU | boiler | 219 | wwseltempoff | selected temperature for off | uint (>=0<=254) | C | false | sensor.boiler_selected_temperature_for_off | sensor.boiler_wwseltempoff |
| 2435 | Greenstar HIU | boiler | 219 | wwseltempsingle | single charge temperature | uint (>=0<=254) | C | true | number.boiler_single_charge_temperature | number.boiler_wwseltempsingle |
| 2436 | Greenstar HIU | boiler | 219 | wwsolartemp | solar boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_solar_boiler_temperature | sensor.boiler_wwsolartemp |
| 2437 | Greenstar HIU | boiler | 219 | wwtype | type | enum [off\|flow\|buffered flow\|buffer\|layered buffer] | false | sensor.boiler_type | sensor.boiler_wwtype | |
| 2438 | Greenstar HIU | boiler | 219 | wwcomfort | comfort | enum [hot\|eco\|intelligent] | true | select.boiler_comfort | select.boiler_wwcomfort | |
| 2439 | Greenstar HIU | boiler | 219 | wwcomfort1 | comfort mode | enum [high comfort\|eco] | true | select.boiler_comfort_mode | select.boiler_wwcomfort1 | |
| 2440 | Greenstar HIU | boiler | 219 | wwflowtempoffset | flow temperature offset | uint (>=0<=100) | C | true | number.boiler_flow_temperature_offset | number.boiler_wwflowtempoffset |
| 2441 | Greenstar HIU | boiler | 219 | wwchargeoptimization | charge optimization | boolean | true | switch.boiler_charge_optimization | switch.boiler_wwchargeoptimization | |
| 2442 | Greenstar HIU | boiler | 219 | wwmaxpower | max power | uint (>=0<=254) | % | true | number.boiler_max_power | number.boiler_wwmaxpower |
| 2443 | Greenstar HIU | boiler | 219 | wwmaxtemp | maximum temperature | uint (>=0<=70) | C | true | number.boiler_maximum_temperature | number.boiler_wwmaxtemp |
| 2444 | Greenstar HIU | boiler | 219 | wwcircpump | circulation pump available | boolean | true | switch.boiler_circulation_pump_available | switch.boiler_wwcircpump | |
| 2445 | Greenstar HIU | boiler | 219 | wwchargetype | charging type | enum [chargepump\|3-way valve] | false | sensor.boiler_charging_type | sensor.boiler_wwchargetype | |
| 2446 | Greenstar HIU | boiler | 219 | wwhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_wwhyston |
| 2447 | Greenstar HIU | boiler | 219 | wwhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_wwhystoff |
| 2448 | Greenstar HIU | boiler | 219 | wwdisinfectiontemp | disinfection temperature | uint (>=0<=254) | C | true | number.boiler_disinfection_temperature | number.boiler_wwdisinfectiontemp |
| 2449 | Greenstar HIU | boiler | 219 | wwcircmode | circulation pump mode | enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous] | true | select.boiler_circulation_pump_mode | select.boiler_wwcircmode | |
| 2450 | Greenstar HIU | boiler | 219 | wwcirc | circulation active | boolean | true | switch.boiler_circulation_active | switch.boiler_wwcirc | |
| 2451 | Greenstar HIU | boiler | 219 | wwcurtemp | current intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_intern_temperature | sensor.boiler_wwcurtemp |
| 2452 | Greenstar HIU | boiler | 219 | wwcurtemp2 | current extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_extern_temperature | sensor.boiler_wwcurtemp2 |
| 2453 | Greenstar HIU | boiler | 219 | wwcurflow | current tap water flow | uint (>=0<=25) | l/min | false | sensor.boiler_current_tap_water_flow | sensor.boiler_wwcurflow |
| 2454 | Greenstar HIU | boiler | 219 | wwstoragetemp1 | storage intern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_intern_temperature | sensor.boiler_wwstoragetemp1 |
| 2455 | Greenstar HIU | boiler | 219 | wwstoragetemp2 | storage extern temperature | ushort (>=0<=3199) | C | false | sensor.boiler_storage_extern_temperature | sensor.boiler_wwstoragetemp2 |
| 2456 | Greenstar HIU | boiler | 219 | wwactivated | activated | boolean | true | switch.boiler_activated | switch.boiler_wwactivated | |
| 2457 | Greenstar HIU | boiler | 219 | wwonetime | one time charging | boolean | true | switch.boiler_one_time_charging | switch.boiler_wwonetime | |
| 2458 | Greenstar HIU | boiler | 219 | wwdisinfecting | disinfecting | boolean | true | switch.boiler_disinfecting | switch.boiler_wwdisinfecting | |
| 2459 | Greenstar HIU | boiler | 219 | wwcharging | charging | boolean | false | binary_sensor.boiler_charging | binary_sensor.boiler_wwcharging | |
| 2460 | Greenstar HIU | boiler | 219 | wwrecharging | recharging | boolean | false | binary_sensor.boiler_recharging | binary_sensor.boiler_wwrecharging | |
| 2461 | Greenstar HIU | boiler | 219 | wwtempok | temperature ok | boolean | false | binary_sensor.boiler_temperature_ok | binary_sensor.boiler_wwtempok | |
| 2462 | Greenstar HIU | boiler | 219 | wwactive | active | boolean | false | binary_sensor.boiler_active | binary_sensor.boiler_wwactive | |
| 2463 | Greenstar HIU | boiler | 219 | ww3wayvalve | 3-way valve active | boolean | false | binary_sensor.boiler_3-way_valve_active | binary_sensor.boiler_ww3wayvalve | |
| 2464 | Greenstar HIU | boiler | 219 | wwsetpumppower | set pump power | uint (>=0<=100) | % | false | sensor.boiler_set_pump_power | sensor.boiler_wwsetpumppower |
| 2465 | Greenstar HIU | boiler | 219 | wwmixertemp | mixer temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixer_temperature | sensor.boiler_wwmixertemp |
| 2466 | Greenstar HIU | boiler | 219 | wwcylmiddletemp | cylinder middle temperature (TS3) | ushort (>=0<=3199) | C | false | sensor.boiler_cylinder_middle_temperature_(TS3) | sensor.boiler_wwcylmiddletemp |
| 2467 | Greenstar HIU | boiler | 219 | wwstarts | starts | ulong (>=0<=65533) | false | sensor.boiler_starts | sensor.boiler_wwstarts | |
| 2468 | Greenstar HIU | boiler | 219 | wwworkm | active time | time (>=0<=65533) | minutes | false | sensor.boiler_active_time | sensor.boiler_wwworkm |
| 2469 | Logamax Plus GB122/Condense 2300 | boiler | 234 | reset | Reset | cmd [-\|maintenance\|error] | true | sensor.boiler_Reset | sensor.boiler_reset | |
| 2470 | Logamax Plus GB122/Condense 2300 | boiler | 234 | heatingactive | heating active | boolean | false | binary_sensor.boiler_heating_active | binary_sensor.boiler_heatingactive | |
| 2471 | Logamax Plus GB122/Condense 2300 | boiler | 234 | tapwateractive | tapwater active | boolean | false | binary_sensor.boiler_tapwater_active | binary_sensor.boiler_tapwateractive | |
| 2472 | Logamax Plus GB122/Condense 2300 | boiler | 234 | selflowtemp | selected flow temperature | uint (>=0<=254) | C | true | number.boiler_selected_flow_temperature | number.boiler_selflowtemp |
| 2473 | Logamax Plus GB122/Condense 2300 | boiler | 234 | heatingpumpmod | heating pump modulation | uint (>=0<=100) | % | false | sensor.boiler_heating_pump_modulation | sensor.boiler_heatingpumpmod |
| 2474 | Logamax Plus GB122/Condense 2300 | boiler | 234 | outdoortemp | outside temperature | short (>=-3199<=3199) | C | false | sensor.boiler_outside_temperature | sensor.boiler_outdoortemp |
| 2475 | Logamax Plus GB122/Condense 2300 | boiler | 234 | curflowtemp | current flow temperature | ushort (>=0<=3199) | C | false | sensor.boiler_current_flow_temperature | sensor.boiler_curflowtemp |
| 2476 | Logamax Plus GB122/Condense 2300 | boiler | 234 | rettemp | return temperature | ushort (>=0<=3199) | C | false | sensor.boiler_return_temperature | sensor.boiler_rettemp |
| 2477 | Logamax Plus GB122/Condense 2300 | boiler | 234 | switchtemp | mixing switch temperature | ushort (>=0<=3199) | C | false | sensor.boiler_mixing_switch_temperature | sensor.boiler_switchtemp |
| 2478 | Logamax Plus GB122/Condense 2300 | boiler | 234 | syspress | system pressure | uint (>=0<=25) | bar | false | sensor.boiler_system_pressure | sensor.boiler_syspress |
| 2479 | Logamax Plus GB122/Condense 2300 | boiler | 234 | boiltemp | actual boiler temperature | ushort (>=0<=3199) | C | false | sensor.boiler_actual_boiler_temperature | sensor.boiler_boiltemp |
| 2480 | Logamax Plus GB122/Condense 2300 | boiler | 234 | exhausttemp | exhaust temperature | ushort (>=0<=3199) | C | false | sensor.boiler_exhaust_temperature | sensor.boiler_exhausttemp |
| 2481 | Logamax Plus GB122/Condense 2300 | boiler | 234 | burngas | gas | boolean | false | binary_sensor.boiler_gas | binary_sensor.boiler_burngas | |
| 2482 | Logamax Plus GB122/Condense 2300 | boiler | 234 | burngas2 | gas stage 2 | boolean | false | binary_sensor.boiler_gas_stage_2 | binary_sensor.boiler_burngas2 | |
| 2483 | Logamax Plus GB122/Condense 2300 | boiler | 234 | flamecurr | flame current | ushort (>=0<=3199) | µA | false | sensor.boiler_flame_current | sensor.boiler_flamecurr |
| 2484 | Logamax Plus GB122/Condense 2300 | boiler | 234 | heatingpump | heating pump | boolean | false | binary_sensor.boiler_heating_pump | binary_sensor.boiler_heatingpump | |
| 2485 | Logamax Plus GB122/Condense 2300 | boiler | 234 | fanwork | fan | boolean | false | binary_sensor.boiler_fan | binary_sensor.boiler_fanwork | |
| 2486 | Logamax Plus GB122/Condense 2300 | boiler | 234 | ignwork | ignition | boolean | false | binary_sensor.boiler_ignition | binary_sensor.boiler_ignwork | |
| 2487 | Logamax Plus GB122/Condense 2300 | boiler | 234 | oilpreheat | oil preheating | boolean | false | binary_sensor.boiler_oil_preheating | binary_sensor.boiler_oilpreheat | |
| 2488 | Logamax Plus GB122/Condense 2300 | boiler | 234 | heatingactivated | heating activated | boolean | true | switch.boiler_heating_activated | switch.boiler_heatingactivated | |
| 2489 | Logamax Plus GB122/Condense 2300 | boiler | 234 | heatingtemp | heating temperature | uint (>=0<=254) | C | true | number.boiler_heating_temperature | number.boiler_heatingtemp |
| 2490 | Logamax Plus GB122/Condense 2300 | boiler | 234 | pumpmodmax | boiler pump max power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_max_power | number.boiler_pumpmodmax |
| 2491 | Logamax Plus GB122/Condense 2300 | boiler | 234 | pumpmodmin | boiler pump min power | uint (>=0<=100) | % | true | number.boiler_boiler_pump_min_power | number.boiler_pumpmodmin |
| 2492 | Logamax Plus GB122/Condense 2300 | boiler | 234 | pumpmode | boiler pump mode | enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4] | true | select.boiler_boiler_pump_mode | select.boiler_pumpmode | |
| 2493 | Logamax Plus GB122/Condense 2300 | boiler | 234 | pumpdelay | pump delay | uint (>=0<=254) | minutes | true | number.boiler_pump_delay | number.boiler_pumpdelay |
| 2494 | Logamax Plus GB122/Condense 2300 | boiler | 234 | burnminperiod | burner min period | uint (>=0<=254) | minutes | true | number.boiler_burner_min_period | number.boiler_burnminperiod |
| 2495 | Logamax Plus GB122/Condense 2300 | boiler | 234 | burnminpower | burner min power | uint (>=0<=100) | % | true | number.boiler_burner_min_power | number.boiler_burnminpower |
| 2496 | Logamax Plus GB122/Condense 2300 | boiler | 234 | burnmaxpower | burner max power | uint (>=0<=254) | % | true | number.boiler_burner_max_power | number.boiler_burnmaxpower |
| 2497 | Logamax Plus GB122/Condense 2300 | boiler | 234 | boilhyston | hysteresis on temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_on_temperature | number.boiler_boilhyston |
| 2498 | Logamax Plus GB122/Condense 2300 | boiler | 234 | boilhystoff | hysteresis off temperature | int (>=-126<=126) | C | true | number.boiler_hysteresis_off_temperature | number.boiler_boilhystoff |
| 2499 | Logamax Plus GB122/Condense 2300 | boiler | 234 | boil2hyston | hysteresis stage 2 on temperature | int (>=-20<=0) | C | true | number.boiler_hysteresis_stage_2_on_temperature | number.boiler_boil2hyston |
| 2500 | Logamax Plus GB122/Condense 2300 | boiler | 234 | boil2hystoff | hysteresis stage 2 off temperature | int (>=0<=20) | C | true | number.boiler_hysteresis_stage_2_off_temperature | number.boiler_boil2hystoff |
| The file is too large to be shown. View Raw |