# Changelog
## [3.6.5]
## **IMPORTANT! BREAKING CHANGES**
- new device WATER shows dhw entities from MM100 and SM100 in dhw setting
## Added
- some more entities for dhw with SM100 module
- thermostat boost mode and boost time [#1446](https://github.com/emsesp/EMS-ESP32/issues/1446)
- heatpump energy meters [#1463](https://github.com/emsesp/EMS-ESP32/issues/1463)
- heatpump max power [#1475](https://github.com/emsesp/EMS-ESP32/issues/1475)
- checkbox for MQTT-TLS enable [#1474](https://github.com/emsesp/EMS-ESP32/issues/1474)
- added SK (Slovencina) language. Thanks @misa1515
- CPU info [#1497](https://github.com/emsesp/EMS-ESP32/pull/1497)
## Fixed
- exhaust temperature for some boilers
- add back boil2hyst [#1477](https://github.com/emsesp/EMS-ESP32/issues/1477)
- subscribed MQTT topics not detecting changes by EMS-ESP [#1494](https://github.com/emsesp/EMS-ESP32/issues/1494)
## Changed
- use flag for BC400 compatible thermostats, manage different mode settings
- HA don't set entity_category to Diagnostic/Configuration for EMS entities [#1459](https://github.com/emsesp/EMS-ESP32/discussions/1459)