1device namedevice typeproduct idshortnamefullnametype [options...] \| (min/max)uomwriteablediscovery entityid v3.4discovery entityidmodbus unit identifiermodbus blockmodbus scale factormodbus offsetmodbus count
2CS6800i/WLW176iboiler8resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
3CS6800i/WLW176iboiler8heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
4CS6800i/WLW176iboiler8heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
5CS6800i/WLW176iboiler8tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
6CS6800i/WLW176iboiler8selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
7CS6800i/WLW176iboiler8heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
8CS6800i/WLW176iboiler8outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
9CS6800i/WLW176iboiler8curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
10CS6800i/WLW176iboiler8rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
11CS6800i/WLW176iboiler8switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
12CS6800i/WLW176iboiler8syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
13CS6800i/WLW176iboiler8boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
14CS6800i/WLW176iboiler8headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
15CS6800i/WLW176iboiler8heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
16CS6800i/WLW176iboiler8heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
17CS6800i/WLW176iboiler8heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
18CS6800i/WLW176iboiler8pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
19CS6800i/WLW176iboiler8pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
20CS6800i/WLW176iboiler8pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
21CS6800i/WLW176iboiler8pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
22CS6800i/WLW176iboiler8pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
23CS6800i/WLW176iboiler8selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
24CS6800i/WLW176iboiler8curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
25CS6800i/WLW176iboiler8burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
26CS6800i/WLW176iboiler8burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
27CS6800i/WLW176iboiler8burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
28CS6800i/WLW176iboiler8heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
29CS6800i/WLW176iboiler8heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
30CS6800i/WLW176iboiler8ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
31CS6800i/WLW176iboiler8lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
32CS6800i/WLW176iboiler8servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
33CS6800i/WLW176iboiler8servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
34CS6800i/WLW176iboiler8maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
35CS6800i/WLW176iboiler8maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
36CS6800i/WLW176iboiler8maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
37CS6800i/WLW176iboiler8maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
38CS6800i/WLW176iboiler8emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
39CS6800i/WLW176iboiler8emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
40CS6800i/WLW176iboiler8nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
41CS6800i/WLW176iboiler8nrgenergyuint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_energysensor.boiler_dhw_nrg591/10002
42CS6800i/WLW176iboiler8nrgheatenergy heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_heatingsensor.boiler_nrgheat501/100822
43CS6800i/WLW176iboiler8nrgcoolenergy coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_coolingsensor.boiler_nrgcool501/1002642
44CS6800i/WLW176iboiler8metertotalmeter totaluint24 (>=0<=167772)kWhfalsesensor.boiler_meter_totalsensor.boiler_metertotal501/100842
45CS6800i/WLW176iboiler8metercompmeter compressoruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_compressorsensor.boiler_metercomp501/100862
46CS6800i/WLW176iboiler8metereheatmeter e-heateruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_e-heatersensor.boiler_metereheat501/100882
47CS6800i/WLW176iboiler8meterheatmeter heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/100902
48CS6800i/WLW176iboiler8metercoolmeter coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_coolingsensor.boiler_metercool501/1002662
49CS6800i/WLW176iboiler8metermeteruint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/10022
50CS6800i/WLW176iboiler8uptimetotalheatpump total uptimetime (>=0<=279620)minutesfalsesensor.boiler_heatpump_total_uptimesensor.boiler_uptimetotal501/60922
51CS6800i/WLW176iboiler8uptimecontroltotal operating time heattime (>=0<=279620)minutesfalsesensor.boiler_total_operating_time_heatsensor.boiler_uptimecontrol501/60942
52CS6800i/WLW176iboiler8uptimecompheatingoperating time compressor heatingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_heatingsensor.boiler_uptimecompheating501/60962
53CS6800i/WLW176iboiler8uptimecompcoolingoperating time compressor coolingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_coolingsensor.boiler_uptimecompcooling501/60982
54CS6800i/WLW176iboiler8uptimecompoperating time compressortime (>=0<=279620)minutesfalsesensor.boiler_dhw_operating_time_compressorsensor.boiler_dhw_uptimecomp591/6042
55CS6800i/WLW176iboiler8uptimecomppooloperating time compressor pooltime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_poolsensor.boiler_uptimecomppool501/601002
56CS6800i/WLW176iboiler8totalcompstartstotal compressor control startsuint24 (>=0<=16777213)falsesensor.boiler_total_compressor_control_startssensor.boiler_totalcompstarts5011022
57CS6800i/WLW176iboiler8heatingstartsheating control startsuint24 (>=0<=16777213)falsesensor.boiler_heating_control_startssensor.boiler_heatingstarts5011042
58CS6800i/WLW176iboiler8coolingstartscooling control startsuint24 (>=0<=16777213)falsesensor.boiler_cooling_control_startssensor.boiler_coolingstarts5011062
59CS6800i/WLW176iboiler8starts2control starts2uint24 (>=0<=16777213)falsesensor.boiler_dhw_control_starts2sensor.boiler_dhw_starts259162
60CS6800i/WLW176iboiler8poolstartspool control startsuint24 (>=0<=16777213)falsesensor.boiler_pool_control_startssensor.boiler_poolstarts5011082
61CS6800i/WLW176iboiler8nrgconstotaltotal energy consumptionuint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_consumptionsensor.boiler_nrgconstotal5011102
62CS6800i/WLW176iboiler8nrgconscomptotaltotal energy consumption compressoruint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_consumption_compressorsensor.boiler_nrgconscomptotal5011122
63CS6800i/WLW176iboiler8nrgconscompheatingenergy consumption compressor heatinguint24 (>=0<=16777213)kWhfalsesensor.boiler_energy_consumption_compressor_heatingsensor.boiler_nrgconscompheating5011142
64CS6800i/WLW176iboiler8nrgconscompenergy consumption compressoruint24 (>=0<=16777213)kWhfalsesensor.boiler_dhw_energy_consumption_compressorsensor.boiler_dhw_nrgconscomp59182
65CS6800i/WLW176iboiler8nrgconscompcoolingenergy consumption compressor coolinguint24 (>=0<=16777213)kWhfalsesensor.boiler_energy_consumption_compressor_coolingsensor.boiler_nrgconscompcooling5011162
66CS6800i/WLW176iboiler8nrgconscomppoolenergy consumption compressor pooluint24 (>=0<=16777213)kWhfalsesensor.boiler_energy_consumption_compressor_poolsensor.boiler_nrgconscomppool5011182
67CS6800i/WLW176iboiler8auxelecheatnrgconstotaltotal aux elec. heater energy consumptionuint24 (>=0<=16777213)kWhfalsesensor.boiler_total_aux_elec._heater_energy_consumptionsensor.boiler_auxelecheatnrgconstotal5011202
68CS6800i/WLW176iboiler8auxelecheatnrgconsheatingaux elec. heater energy consumption heatinguint24 (>=0<=16777213)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_heatingsensor.boiler_auxelecheatnrgconsheating5011222
69CS6800i/WLW176iboiler8auxelecheatnrgconsaux elec. heater energy consumptionuint24 (>=0<=16777213)kWhfalsesensor.boiler_dhw_aux_elec._heater_energy_consumptionsensor.boiler_dhw_auxelecheatnrgcons591102
70CS6800i/WLW176iboiler8auxelecheatnrgconspoolaux elec. heater energy consumption pooluint24 (>=0<=16777213)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_poolsensor.boiler_auxelecheatnrgconspool5011242
71CS6800i/WLW176iboiler8nrgsupptotaltotal energy supplieduint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_suppliedsensor.boiler_nrgsupptotal5011262
72CS6800i/WLW176iboiler8nrgsuppheatingtotal energy supplied heatinguint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_supplied_heatingsensor.boiler_nrgsuppheating5011282
73CS6800i/WLW176iboiler8nrgsupptotal energy warm supplieduint24 (>=0<=16777213)kWhfalsesensor.boiler_dhw_total_energy_warm_suppliedsensor.boiler_dhw_nrgsupp591122
74CS6800i/WLW176iboiler8nrgsuppcoolingtotal energy supplied coolinguint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_supplied_coolingsensor.boiler_nrgsuppcooling5011302
75CS6800i/WLW176iboiler8nrgsupppooltotal energy supplied pooluint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_supplied_poolsensor.boiler_nrgsupppool5011322
76CS6800i/WLW176iboiler8hppowercompressor power outputuint8 (>=0<=25)kWfalsesensor.boiler_compressor_power_outputsensor.boiler_hppower501/101341
77CS6800i/WLW176iboiler8hpmaxpowercompressor max poweruint8 (>=0<=100)%truenumber.boiler_compressor_max_powernumber.boiler_hpmaxpower5011351
78CS6800i/WLW176iboiler8hpsetdiffpressset differental pressureuint8 (>=150<=750)mbartruenumber.boiler_set_differental_pressurenumber.boiler_hpsetdiffpress50501361
79CS6800i/WLW176iboiler8hpcomponhp compressorbooleanfalsebinary_sensor.boiler_hp_compressorbinary_sensor.boiler_hpcompon5011371
80CS6800i/WLW176iboiler8hpactivitycompressor activityenum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost]falsesensor.boiler_compressor_activitysensor.boiler_hpactivity5011381
81CS6800i/WLW176iboiler8hpbrinepumpspdbrine pump speeduint8 (>=0<=100)%falsesensor.boiler_brine_pump_speedsensor.boiler_hpbrinepumpspd5011391
82CS6800i/WLW176iboiler8hpswitchvalveswitch valvebooleanfalsebinary_sensor.boiler_switch_valvebinary_sensor.boiler_hpswitchvalve5011401
83CS6800i/WLW176iboiler8hpcompspdcompressor speeduint8 (>=0<=100)%falsesensor.boiler_compressor_speedsensor.boiler_hpcompspd5011411
84CS6800i/WLW176iboiler8hpcircspdcirculation pump speeduint8 (>=0<=100)%falsesensor.boiler_circulation_pump_speedsensor.boiler_hpcircspd5011421
85CS6800i/WLW176iboiler8hpbrineinbrine in/evaporatorint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_in/evaporatorsensor.boiler_hpbrinein501/101431
86CS6800i/WLW176iboiler8hpbrineoutbrine out/condenserint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_out/condensersensor.boiler_hpbrineout501/101441
87CS6800i/WLW176iboiler8hptc0heat carrier return (TC0)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_return_(TC0)sensor.boiler_hptc0501/101451
88CS6800i/WLW176iboiler8hptc1heat carrier forward (TC1)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_forward_(TC1)sensor.boiler_hptc1501/101461
89CS6800i/WLW176iboiler8hptc3condenser temperature (TC3)int16 (>=-3199<=3199)Cfalsesensor.boiler_condenser_temperature_(TC3)sensor.boiler_hptc3501/101471
90CS6800i/WLW176iboiler8hptr1compressor temperature (TR1)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_temperature_(TR1)sensor.boiler_hptr1501/101481
91CS6800i/WLW176iboiler8hptr3refrigerant temperature liquid side (condenser output) (TR3)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3)sensor.boiler_hptr3501/101491
92CS6800i/WLW176iboiler8hptr4evaporator inlet temperature (TR4)int16 (>=-3199<=3199)Cfalsesensor.boiler_evaporator_inlet_temperature_(TR4)sensor.boiler_hptr4501/101501
93CS6800i/WLW176iboiler8hptr5compressor inlet temperature (TR5)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_inlet_temperature_(TR5)sensor.boiler_hptr5501/101511
94CS6800i/WLW176iboiler8hptr6compressor outlet temperature (TR6)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_outlet_temperature_(TR6)sensor.boiler_hptr6501/101521
95CS6800i/WLW176iboiler8hptr7refrigerant temperature gas side (condenser input) (TR7)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7)sensor.boiler_hptr7501/101531
96CS6800i/WLW176iboiler8hptl2air inlet temperature (TL2)int16 (>=-3199<=3199)Cfalsesensor.boiler_air_inlet_temperature_(TL2)sensor.boiler_hptl2501/101541
97CS6800i/WLW176iboiler8hppl1low pressure side temperature (PL1)int16 (>=-3199<=3199)Cfalsesensor.boiler_low_pressure_side_temperature_(PL1)sensor.boiler_hppl1501/101551
98CS6800i/WLW176iboiler8hpph1high pressure side temperature (PH1)int16 (>=-3199<=3199)Cfalsesensor.boiler_high_pressure_side_temperature_(PH1)sensor.boiler_hpph1501/101561
99CS6800i/WLW176iboiler8hpta4drain pan temp (TA4)int16 (>=-3199<=3199)Cfalsesensor.boiler_drain_pan_temp_(TA4)sensor.boiler_hpta4501/101571
100CS6800i/WLW176iboiler8hptw1reservoir temp (TW1)int16 (>=-3199<=3199)Cfalsesensor.boiler_reservoir_temp_(TW1)sensor.boiler_hptw1501/101581
101CS6800i/WLW176iboiler8poolsettemppool set temperatureuint8 (>=0<=127)Ctruenumber.boiler_pool_set_temperaturenumber.boiler_poolsettemp501/21591
102CS6800i/WLW176iboiler8hp4way4-way valve (VR4)enum [cooling & defrost\|heating & dhw]falsesensor.boiler_4-way_valve_(VR4)sensor.boiler_hp4way5011601
103CS6800i/WLW176iboiler8hpin1input 1 statebooleanfalsebinary_sensor.boiler_input_1_statebinary_sensor.boiler_hpin15011611
104CS6800i/WLW176iboiler8hpin1optinput 1 optionsstringtruesensor.boiler_input_1_optionssensor.boiler_hpin1opt5011628
105CS6800i/WLW176iboiler8hpin2input 2 statebooleanfalsebinary_sensor.boiler_input_2_statebinary_sensor.boiler_hpin25011701
106CS6800i/WLW176iboiler8hpin2optinput 2 optionsstringtruesensor.boiler_input_2_optionssensor.boiler_hpin2opt5011718
107CS6800i/WLW176iboiler8hpin3input 3 statebooleanfalsebinary_sensor.boiler_input_3_statebinary_sensor.boiler_hpin35011791
108CS6800i/WLW176iboiler8hpin3optinput 3 optionsstringtruesensor.boiler_input_3_optionssensor.boiler_hpin3opt5011808
109CS6800i/WLW176iboiler8hpin4input 4 statebooleanfalsebinary_sensor.boiler_input_4_statebinary_sensor.boiler_hpin45011881
110CS6800i/WLW176iboiler8hpin4optinput 4 optionsstringtruesensor.boiler_input_4_optionssensor.boiler_hpin4opt5011898
111CS6800i/WLW176iboiler8maxheatcompheat limit compressorenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_compressorselect.boiler_maxheatcomp5011971
112CS6800i/WLW176iboiler8maxheatheatheat limit heatingenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_heatingselect.boiler_maxheatheat5011981
113CS6800i/WLW176iboiler8maxheatheat limitenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_dhw_heat_limitselect.boiler_dhw_maxheat591141
114CS6800i/WLW176iboiler8mandefrostmanual defrostbooleantrueswitch.boiler_manual_defrostswitch.boiler_mandefrost5011991
115CS6800i/WLW176iboiler8pvcoolingcooling only with PVbooleantrueswitch.boiler_cooling_only_with_PVswitch.boiler_pvcooling5012001
116CS6800i/WLW176iboiler8auxheateronlyaux heater onlybooleantrueswitch.boiler_aux_heater_onlyswitch.boiler_auxheateronly5012011
117CS6800i/WLW176iboiler8auxheateroffdisable aux heaterbooleantrueswitch.boiler_disable_aux_heaterswitch.boiler_auxheateroff5012021
118CS6800i/WLW176iboiler8auxheaterstatusaux heater statusuint8 (>=0<=100)%falsesensor.boiler_aux_heater_statussensor.boiler_auxheaterstatus5012031
119CS6800i/WLW176iboiler8auxheaterdelayaux heater on delayuint16 (>=10<=1000)K*mintruenumber.boiler_aux_heater_on_delaynumber.boiler_auxheaterdelay50102041
120CS6800i/WLW176iboiler8auxmaxlimitaux heater max limituint8 (>=0<=10)Ktruenumber.boiler_aux_heater_max_limitnumber.boiler_auxmaxlimit501/102051
121CS6800i/WLW176iboiler8auxlimitstartaux heater limit startuint8 (>=0<=10)Ktruenumber.boiler_aux_heater_limit_startnumber.boiler_auxlimitstart501/102061
122CS6800i/WLW176iboiler8auxheatrmodeaux heater modeenum [eco\|comfort]trueselect.boiler_aux_heater_modeselect.boiler_auxheatrmode5012071
123CS6800i/WLW176iboiler8hphystheaton/off hyst heatuint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_heatnumber.boiler_hphystheat5052081
124CS6800i/WLW176iboiler8hphystcoolon/off hyst cooluint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_coolnumber.boiler_hphystcool5052091
125CS6800i/WLW176iboiler8hphystpoolon/off hyst pooluint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_poolnumber.boiler_hphystpool5052101
126CS6800i/WLW176iboiler8silentmodesilent modeenum [off\|auto\|on]trueselect.boiler_silent_modeselect.boiler_silentmode5012111
127CS6800i/WLW176iboiler8silentfromsilent mode fromuint8 (>=0<=3810)minutestruenumber.boiler_silent_mode_fromnumber.boiler_silentfrom50152121
128CS6800i/WLW176iboiler8silenttosilent mode touint8 (>=0<=3810)minutestruenumber.boiler_silent_mode_tonumber.boiler_silentto50152131
129CS6800i/WLW176iboiler8mintempsilentmin outside temp for silent modeint8 (>=-126<=126)Ctruenumber.boiler_min_outside_temp_for_silent_modenumber.boiler_mintempsilent5012141
130CS6800i/WLW176iboiler8tempparmodeoutside temp parallel modeint8 (>=-126<=126)Ctruenumber.boiler_outside_temp_parallel_modenumber.boiler_tempparmode5012151
131CS6800i/WLW176iboiler8auxheatmixaux heater mixing valveint8 (>=-100<=100)%falsesensor.boiler_aux_heater_mixing_valvesensor.boiler_auxheatmix5012161
132CS6800i/WLW176iboiler8tempdiffheattemp diff TC3/TC0 heatuint8 (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_heatnumber.boiler_tempdiffheat501/102171
133CS6800i/WLW176iboiler8tempdiffcooltemp diff TC3/TC0 cooluint8 (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_coolnumber.boiler_tempdiffcool501/102181
134CS6800i/WLW176iboiler8vpcoolingvalve/pump coolingbooleantrueswitch.boiler_valve/pump_coolingswitch.boiler_vpcooling5012191
135CS6800i/WLW176iboiler8heatcableheating cablebooleantrueswitch.boiler_heating_cableswitch.boiler_heatcable5012201
136CS6800i/WLW176iboiler8vc0valveVC0 valvebooleantrueswitch.boiler_VC0_valveswitch.boiler_vc0valve5012211
137CS6800i/WLW176iboiler8primepumpprimary heatpumpbooleantrueswitch.boiler_primary_heatpumpswitch.boiler_primepump5012221
138CS6800i/WLW176iboiler8primepumpmodprimary heatpump modulationuint8 (>=0<=100)%truenumber.boiler_primary_heatpump_modulationnumber.boiler_primepumpmod5012231
139CS6800i/WLW176iboiler8hp3way3-way valvebooleantrueswitch.boiler_3-way_valveswitch.boiler_hp3way5012241
140CS6800i/WLW176iboiler8elheatstep1el. heater step 1booleantrueswitch.boiler_el._heater_step_1switch.boiler_elheatstep15012251
141CS6800i/WLW176iboiler8elheatstep2el. heater step 2booleantrueswitch.boiler_el._heater_step_2switch.boiler_elheatstep25012261
142CS6800i/WLW176iboiler8elheatstep3el. heater step 3booleantrueswitch.boiler_el._heater_step_3switch.boiler_elheatstep35012271
143CS6800i/WLW176iboiler8hpea0condensate reservoir heating (EA0)booleanfalsebinary_sensor.boiler_condensate_reservoir_heating_(EA0)binary_sensor.boiler_hpea05012281
144CS6800i/WLW176iboiler8hppumpmodeprimary heatpump modeenum [auto\|continuous]trueselect.boiler_primary_heatpump_modeselect.boiler_hppumpmode5012291
145CS6800i/WLW176iboiler8fanfanuint8 (>=20<=100)%truenumber.boiler_fannumber.boiler_fan5012301
146CS6800i/WLW176iboiler8shutdownshutdowncmd [off\|on]truesensor.boiler_shutdownsensor.boiler_shutdown5012311
147CS6800i/WLW176iboiler8alternatingopalternating operationbooleantrueswitch.boiler_dhw_alternating_operationswitch.boiler_dhw_alternatingop591151
148CS6800i/WLW176iboiler8altopprioheatprioritise heating during dhwuint8 (>=20<=120)minutestruenumber.boiler_dhw_prioritise_heating_during_dhwnumber.boiler_dhw_altopprioheat591161
149CS6800i/WLW176iboiler8altopprioprioritise dhw during heatinguint8 (>=30<=120)minutestruenumber.boiler_dhw_prioritise_dhw_during_heatingnumber.boiler_dhw_altopprio591171
150CS6800i/WLW176iboiler8comfoffcomfort switch offuint8 (>=15<=65)Ctruenumber.boiler_dhw_comfort_switch_offnumber.boiler_dhw_comfoff591181
151CS6800i/WLW176iboiler8ecooffeco switch offuint8 (>=15<=65)Ctruenumber.boiler_dhw_eco_switch_offnumber.boiler_dhw_ecooff591191
152CS6800i/WLW176iboiler8ecoplusoffeco+ switch offuint8 (>=48<=63)Ctruenumber.boiler_dhw_eco+_switch_offnumber.boiler_dhw_ecoplusoff591201
153CS6800i/WLW176iboiler8comfdiffcomfort diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_comfort_diffnumber.boiler_dhw_comfdiff591211
154CS6800i/WLW176iboiler8ecodiffeco diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_eco_diffnumber.boiler_dhw_ecodiff591221
155CS6800i/WLW176iboiler8ecoplusdiffeco+ diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_eco+_diffnumber.boiler_dhw_ecoplusdiff591231
156CS6800i/WLW176iboiler8comfstopcomfort stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_comfort_stop_tempnumber.boiler_dhw_comfstop591241
157CS6800i/WLW176iboiler8ecostopeco stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_eco_stop_tempnumber.boiler_dhw_ecostop591251
158CS6800i/WLW176iboiler8ecoplusstopeco+ stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_eco+_stop_tempnumber.boiler_dhw_ecoplusstop591261
159CS6800i/WLW176iboiler8hpcircpumpcirculation pump available during dhwbooleantrueswitch.boiler_dhw_circulation_pump_available_during_dhwswitch.boiler_dhw_hpcircpump591271
160CS6800i/WLW176iboiler8tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
161CS6800i/WLW176iboiler8settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
162CS6800i/WLW176iboiler8seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
163CS6800i/WLW176iboiler8seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
164CS6800i/WLW176iboiler8tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
165CS6800i/WLW176iboiler8seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
166CS6800i/WLW176iboiler8seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
167CS6800i/WLW176iboiler8solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
168CS6800i/WLW176iboiler8typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
169CS6800i/WLW176iboiler8comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
170CS6800i/WLW176iboiler8comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
171CS6800i/WLW176iboiler8flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
172CS6800i/WLW176iboiler8chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
173CS6800i/WLW176iboiler8maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
174CS6800i/WLW176iboiler8maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
175CS6800i/WLW176iboiler8circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
176CS6800i/WLW176iboiler8chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
177CS6800i/WLW176iboiler8hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
178CS6800i/WLW176iboiler8hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
179CS6800i/WLW176iboiler8disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
180CS6800i/WLW176iboiler8circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
181CS6800i/WLW176iboiler8circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
182CS6800i/WLW176iboiler8curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
183CS6800i/WLW176iboiler8curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
184CS6800i/WLW176iboiler8curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
185CS6800i/WLW176iboiler8storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
186CS6800i/WLW176iboiler8storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
187CS6800i/WLW176iboiler8activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
188CS6800i/WLW176iboiler8onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
189CS6800i/WLW176iboiler8disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
190CS6800i/WLW176iboiler8chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
191CS6800i/WLW176iboiler8rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
192CS6800i/WLW176iboiler8tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
193CS6800i/WLW176iboiler8activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
194CS6800i/WLW176iboiler83wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
195CS6800i/WLW176iboiler8mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
196CS6800i/WLW176iboiler8cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
197CS6800i/WLW176iboiler8startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
198CS6800i/WLW176iboiler8workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
199C1200Wboiler12resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
200C1200Wboiler12heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
201C1200Wboiler12heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
202C1200Wboiler12tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
203C1200Wboiler12selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
204C1200Wboiler12heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
205C1200Wboiler12outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
206C1200Wboiler12curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
207C1200Wboiler12rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
208C1200Wboiler12switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
209C1200Wboiler12syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
210C1200Wboiler12boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
211C1200Wboiler12headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
212C1200Wboiler12exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
213C1200Wboiler12burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
214C1200Wboiler12burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
215C1200Wboiler12flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
216C1200Wboiler12fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
217C1200Wboiler12ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
218C1200Wboiler12oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
219C1200Wboiler12burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
220C1200Wboiler12burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
221C1200Wboiler12burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
222C1200Wboiler12absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
223C1200Wboiler12heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
224C1200Wboiler12boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
225C1200Wboiler12boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
226C1200Wboiler12boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
227C1200Wboiler12boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
228C1200Wboiler12curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
229C1200Wboiler12curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
230C1200Wboiler12curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
231C1200Wboiler12summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
232C1200Wboiler12nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
233C1200Wboiler12nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
234C1200Wboiler12heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
235C1200Wboiler12heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
236C1200Wboiler12heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
237C1200Wboiler12pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
238C1200Wboiler12pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
239C1200Wboiler12pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
240C1200Wboiler12pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
241C1200Wboiler12pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
242C1200Wboiler12selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
243C1200Wboiler12curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
244C1200Wboiler12burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
245C1200Wboiler12burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
246C1200Wboiler12burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
247C1200Wboiler12heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
248C1200Wboiler12heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
249C1200Wboiler12ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
250C1200Wboiler12lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
251C1200Wboiler12servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
252C1200Wboiler12servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
253C1200Wboiler12maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
254C1200Wboiler12maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
255C1200Wboiler12maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
256C1200Wboiler12maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
257C1200Wboiler12emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
258C1200Wboiler12emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
259C1200Wboiler12meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
260C1200Wboiler12metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
261C1200Wboiler12gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
262C1200Wboiler12gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
263C1200Wboiler12nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
264C1200Wboiler12nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
265C1200Wboiler12tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
266C1200Wboiler12settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
267C1200Wboiler12seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
268C1200Wboiler12seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
269C1200Wboiler12tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
270C1200Wboiler12seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
271C1200Wboiler12seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
272C1200Wboiler12solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
273C1200Wboiler12typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
274C1200Wboiler12comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
275C1200Wboiler12comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
276C1200Wboiler12flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
277C1200Wboiler12chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
278C1200Wboiler12maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
279C1200Wboiler12maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
280C1200Wboiler12circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
281C1200Wboiler12chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
282C1200Wboiler12hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
283C1200Wboiler12hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
284C1200Wboiler12disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
285C1200Wboiler12circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
286C1200Wboiler12circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
287C1200Wboiler12curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
288C1200Wboiler12curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
289C1200Wboiler12curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
290C1200Wboiler12storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
291C1200Wboiler12storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
292C1200Wboiler12activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
293C1200Wboiler12onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
294C1200Wboiler12disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
295C1200Wboiler12chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
296C1200Wboiler12rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
297C1200Wboiler12tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
298C1200Wboiler12activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
299C1200Wboiler123wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
300C1200Wboiler12mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
301C1200Wboiler12cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
302C1200Wboiler12startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
303C1200Wboiler12workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
304C1200Wboiler12nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
305C1200Wboiler12nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
306C1200Wboiler12nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
307C1200Wboiler12nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
308BK13/BK15/Smartline/GB1x2boiler64resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
309BK13/BK15/Smartline/GB1x2boiler64heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
310BK13/BK15/Smartline/GB1x2boiler64heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
311BK13/BK15/Smartline/GB1x2boiler64tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
312BK13/BK15/Smartline/GB1x2boiler64selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
313BK13/BK15/Smartline/GB1x2boiler64heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
314BK13/BK15/Smartline/GB1x2boiler64outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
315BK13/BK15/Smartline/GB1x2boiler64curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
316BK13/BK15/Smartline/GB1x2boiler64rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
317BK13/BK15/Smartline/GB1x2boiler64switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
318BK13/BK15/Smartline/GB1x2boiler64syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
319BK13/BK15/Smartline/GB1x2boiler64boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
320BK13/BK15/Smartline/GB1x2boiler64headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
321BK13/BK15/Smartline/GB1x2boiler64exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
322BK13/BK15/Smartline/GB1x2boiler64burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
323BK13/BK15/Smartline/GB1x2boiler64burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
324BK13/BK15/Smartline/GB1x2boiler64flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
325BK13/BK15/Smartline/GB1x2boiler64fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
326BK13/BK15/Smartline/GB1x2boiler64ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
327BK13/BK15/Smartline/GB1x2boiler64oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
328BK13/BK15/Smartline/GB1x2boiler64burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
329BK13/BK15/Smartline/GB1x2boiler64burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
330BK13/BK15/Smartline/GB1x2boiler64burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
331BK13/BK15/Smartline/GB1x2boiler64absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
332BK13/BK15/Smartline/GB1x2boiler64heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
333BK13/BK15/Smartline/GB1x2boiler64boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
334BK13/BK15/Smartline/GB1x2boiler64boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
335BK13/BK15/Smartline/GB1x2boiler64boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
336BK13/BK15/Smartline/GB1x2boiler64boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
337BK13/BK15/Smartline/GB1x2boiler64curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
338BK13/BK15/Smartline/GB1x2boiler64curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
339BK13/BK15/Smartline/GB1x2boiler64curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
340BK13/BK15/Smartline/GB1x2boiler64summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
341BK13/BK15/Smartline/GB1x2boiler64nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
342BK13/BK15/Smartline/GB1x2boiler64nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
343BK13/BK15/Smartline/GB1x2boiler64heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
344BK13/BK15/Smartline/GB1x2boiler64heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
345BK13/BK15/Smartline/GB1x2boiler64heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
346BK13/BK15/Smartline/GB1x2boiler64pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
347BK13/BK15/Smartline/GB1x2boiler64pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
348BK13/BK15/Smartline/GB1x2boiler64pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
349BK13/BK15/Smartline/GB1x2boiler64pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
350BK13/BK15/Smartline/GB1x2boiler64pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
351BK13/BK15/Smartline/GB1x2boiler64selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
352BK13/BK15/Smartline/GB1x2boiler64curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
353BK13/BK15/Smartline/GB1x2boiler64burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
354BK13/BK15/Smartline/GB1x2boiler64burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
355BK13/BK15/Smartline/GB1x2boiler64burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
356BK13/BK15/Smartline/GB1x2boiler64heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
357BK13/BK15/Smartline/GB1x2boiler64heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
358BK13/BK15/Smartline/GB1x2boiler64ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
359BK13/BK15/Smartline/GB1x2boiler64lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
360BK13/BK15/Smartline/GB1x2boiler64servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
361BK13/BK15/Smartline/GB1x2boiler64servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
362BK13/BK15/Smartline/GB1x2boiler64maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
363BK13/BK15/Smartline/GB1x2boiler64maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
364BK13/BK15/Smartline/GB1x2boiler64maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
365BK13/BK15/Smartline/GB1x2boiler64maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
366BK13/BK15/Smartline/GB1x2boiler64emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
367BK13/BK15/Smartline/GB1x2boiler64emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
368BK13/BK15/Smartline/GB1x2boiler64meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
369BK13/BK15/Smartline/GB1x2boiler64metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
370BK13/BK15/Smartline/GB1x2boiler64gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
371BK13/BK15/Smartline/GB1x2boiler64gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
372BK13/BK15/Smartline/GB1x2boiler64nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
373BK13/BK15/Smartline/GB1x2boiler64nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
374BK13/BK15/Smartline/GB1x2boiler64tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
375BK13/BK15/Smartline/GB1x2boiler64settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
376BK13/BK15/Smartline/GB1x2boiler64seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
377BK13/BK15/Smartline/GB1x2boiler64seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
378BK13/BK15/Smartline/GB1x2boiler64tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
379BK13/BK15/Smartline/GB1x2boiler64seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
380BK13/BK15/Smartline/GB1x2boiler64seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
381BK13/BK15/Smartline/GB1x2boiler64solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
382BK13/BK15/Smartline/GB1x2boiler64typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
383BK13/BK15/Smartline/GB1x2boiler64comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
384BK13/BK15/Smartline/GB1x2boiler64comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
385BK13/BK15/Smartline/GB1x2boiler64flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
386BK13/BK15/Smartline/GB1x2boiler64chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
387BK13/BK15/Smartline/GB1x2boiler64maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
388BK13/BK15/Smartline/GB1x2boiler64maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
389BK13/BK15/Smartline/GB1x2boiler64circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
390BK13/BK15/Smartline/GB1x2boiler64chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
391BK13/BK15/Smartline/GB1x2boiler64hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
392BK13/BK15/Smartline/GB1x2boiler64hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
393BK13/BK15/Smartline/GB1x2boiler64disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
394BK13/BK15/Smartline/GB1x2boiler64circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
395BK13/BK15/Smartline/GB1x2boiler64circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
396BK13/BK15/Smartline/GB1x2boiler64curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
397BK13/BK15/Smartline/GB1x2boiler64curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
398BK13/BK15/Smartline/GB1x2boiler64curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
399BK13/BK15/Smartline/GB1x2boiler64storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
400BK13/BK15/Smartline/GB1x2boiler64storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
401BK13/BK15/Smartline/GB1x2boiler64activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
402BK13/BK15/Smartline/GB1x2boiler64onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
403BK13/BK15/Smartline/GB1x2boiler64disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
404BK13/BK15/Smartline/GB1x2boiler64chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
405BK13/BK15/Smartline/GB1x2boiler64rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
406BK13/BK15/Smartline/GB1x2boiler64tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
407BK13/BK15/Smartline/GB1x2boiler64activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
408BK13/BK15/Smartline/GB1x2boiler643wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
409BK13/BK15/Smartline/GB1x2boiler64mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
410BK13/BK15/Smartline/GB1x2boiler64cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
411BK13/BK15/Smartline/GB1x2boiler64startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
412BK13/BK15/Smartline/GB1x2boiler64workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
413BK13/BK15/Smartline/GB1x2boiler64nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
414BK13/BK15/Smartline/GB1x2boiler64nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
415BK13/BK15/Smartline/GB1x2boiler64nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
416BK13/BK15/Smartline/GB1x2boiler64nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
417GB125/GB135/MC10boiler72resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
418GB125/GB135/MC10boiler72heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
419GB125/GB135/MC10boiler72heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
420GB125/GB135/MC10boiler72tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
421GB125/GB135/MC10boiler72selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
422GB125/GB135/MC10boiler72heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
423GB125/GB135/MC10boiler72outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
424GB125/GB135/MC10boiler72curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
425GB125/GB135/MC10boiler72rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
426GB125/GB135/MC10boiler72switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
427GB125/GB135/MC10boiler72syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
428GB125/GB135/MC10boiler72boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
429GB125/GB135/MC10boiler72headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
430GB125/GB135/MC10boiler72exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
431GB125/GB135/MC10boiler72burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
432GB125/GB135/MC10boiler72burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
433GB125/GB135/MC10boiler72flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
434GB125/GB135/MC10boiler72fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
435GB125/GB135/MC10boiler72ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
436GB125/GB135/MC10boiler72oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
437GB125/GB135/MC10boiler72burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
438GB125/GB135/MC10boiler72burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
439GB125/GB135/MC10boiler72burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
440GB125/GB135/MC10boiler72absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
441GB125/GB135/MC10boiler72heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
442GB125/GB135/MC10boiler72boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
443GB125/GB135/MC10boiler72boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
444GB125/GB135/MC10boiler72boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
445GB125/GB135/MC10boiler72boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
446GB125/GB135/MC10boiler72curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
447GB125/GB135/MC10boiler72curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
448GB125/GB135/MC10boiler72curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
449GB125/GB135/MC10boiler72summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
450GB125/GB135/MC10boiler72nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
451GB125/GB135/MC10boiler72nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
452GB125/GB135/MC10boiler72heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
453GB125/GB135/MC10boiler72heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
454GB125/GB135/MC10boiler72heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
455GB125/GB135/MC10boiler72pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
456GB125/GB135/MC10boiler72pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
457GB125/GB135/MC10boiler72pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
458GB125/GB135/MC10boiler72pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
459GB125/GB135/MC10boiler72pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
460GB125/GB135/MC10boiler72selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
461GB125/GB135/MC10boiler72curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
462GB125/GB135/MC10boiler72burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
463GB125/GB135/MC10boiler72burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
464GB125/GB135/MC10boiler72burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
465GB125/GB135/MC10boiler72heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
466GB125/GB135/MC10boiler72heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
467GB125/GB135/MC10boiler72ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
468GB125/GB135/MC10boiler72lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
469GB125/GB135/MC10boiler72servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
470GB125/GB135/MC10boiler72servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
471GB125/GB135/MC10boiler72maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
472GB125/GB135/MC10boiler72maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
473GB125/GB135/MC10boiler72maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
474GB125/GB135/MC10boiler72maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
475GB125/GB135/MC10boiler72emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
476GB125/GB135/MC10boiler72emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
477GB125/GB135/MC10boiler72meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
478GB125/GB135/MC10boiler72metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
479GB125/GB135/MC10boiler72gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
480GB125/GB135/MC10boiler72gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
481GB125/GB135/MC10boiler72nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
482GB125/GB135/MC10boiler72nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
483GB125/GB135/MC10boiler72tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
484GB125/GB135/MC10boiler72settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
485GB125/GB135/MC10boiler72seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
486GB125/GB135/MC10boiler72seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
487GB125/GB135/MC10boiler72tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
488GB125/GB135/MC10boiler72seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
489GB125/GB135/MC10boiler72seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
490GB125/GB135/MC10boiler72solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
491GB125/GB135/MC10boiler72typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
492GB125/GB135/MC10boiler72comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
493GB125/GB135/MC10boiler72comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
494GB125/GB135/MC10boiler72flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
495GB125/GB135/MC10boiler72chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
496GB125/GB135/MC10boiler72maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
497GB125/GB135/MC10boiler72maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
498GB125/GB135/MC10boiler72circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
499GB125/GB135/MC10boiler72chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
500GB125/GB135/MC10boiler72hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
501GB125/GB135/MC10boiler72hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
502GB125/GB135/MC10boiler72disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
503GB125/GB135/MC10boiler72circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
504GB125/GB135/MC10boiler72circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
505GB125/GB135/MC10boiler72curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
506GB125/GB135/MC10boiler72curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
507GB125/GB135/MC10boiler72curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
508GB125/GB135/MC10boiler72storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
509GB125/GB135/MC10boiler72storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
510GB125/GB135/MC10boiler72activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
511GB125/GB135/MC10boiler72onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
512GB125/GB135/MC10boiler72disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
513GB125/GB135/MC10boiler72chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
514GB125/GB135/MC10boiler72rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
515GB125/GB135/MC10boiler72tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
516GB125/GB135/MC10boiler72activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
517GB125/GB135/MC10boiler723wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
518GB125/GB135/MC10boiler72mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
519GB125/GB135/MC10boiler72cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
520GB125/GB135/MC10boiler72startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
521GB125/GB135/MC10boiler72workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
522GB125/GB135/MC10boiler72nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
523GB125/GB135/MC10boiler72nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
524GB125/GB135/MC10boiler72nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
525GB125/GB135/MC10boiler72nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
526Cascade CM10boiler81resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
527Cascade CM10boiler81heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
528Cascade CM10boiler81heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
529Cascade CM10boiler81tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
530Cascade CM10boiler81selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
531Cascade CM10boiler81heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
532Cascade CM10boiler81outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
533Cascade CM10boiler81curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
534Cascade CM10boiler81rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
535Cascade CM10boiler81switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
536Cascade CM10boiler81syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
537Cascade CM10boiler81boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
538Cascade CM10boiler81headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
539Cascade CM10boiler81exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
540Cascade CM10boiler81burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
541Cascade CM10boiler81burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
542Cascade CM10boiler81flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
543Cascade CM10boiler81fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
544Cascade CM10boiler81ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
545Cascade CM10boiler81oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
546Cascade CM10boiler81burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
547Cascade CM10boiler81burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
548Cascade CM10boiler81burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
549Cascade CM10boiler81absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
550Cascade CM10boiler81heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
551Cascade CM10boiler81boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
552Cascade CM10boiler81boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
553Cascade CM10boiler81boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
554Cascade CM10boiler81boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
555Cascade CM10boiler81curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
556Cascade CM10boiler81curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
557Cascade CM10boiler81curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
558Cascade CM10boiler81summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
559Cascade CM10boiler81nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
560Cascade CM10boiler81nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
561Cascade CM10boiler81heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
562Cascade CM10boiler81heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
563Cascade CM10boiler81heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
564Cascade CM10boiler81pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
565Cascade CM10boiler81pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
566Cascade CM10boiler81pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
567Cascade CM10boiler81pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
568Cascade CM10boiler81pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
569Cascade CM10boiler81selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
570Cascade CM10boiler81curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
571Cascade CM10boiler81burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
572Cascade CM10boiler81burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
573Cascade CM10boiler81burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
574Cascade CM10boiler81heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
575Cascade CM10boiler81heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
576Cascade CM10boiler81ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
577Cascade CM10boiler81lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
578Cascade CM10boiler81servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
579Cascade CM10boiler81servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
580Cascade CM10boiler81maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
581Cascade CM10boiler81maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
582Cascade CM10boiler81maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
583Cascade CM10boiler81maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
584Cascade CM10boiler81emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
585Cascade CM10boiler81emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
586Cascade CM10boiler81meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
587Cascade CM10boiler81metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
588Cascade CM10boiler81gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
589Cascade CM10boiler81gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
590Cascade CM10boiler81nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
591Cascade CM10boiler81nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
592Cascade CM10boiler81tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
593Cascade CM10boiler81settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
594Cascade CM10boiler81seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
595Cascade CM10boiler81seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
596Cascade CM10boiler81tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
597Cascade CM10boiler81seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
598Cascade CM10boiler81seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
599Cascade CM10boiler81solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
600Cascade CM10boiler81typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
601Cascade CM10boiler81comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
602Cascade CM10boiler81comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
603Cascade CM10boiler81flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
604Cascade CM10boiler81chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
605Cascade CM10boiler81maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
606Cascade CM10boiler81maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
607Cascade CM10boiler81circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
608Cascade CM10boiler81chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
609Cascade CM10boiler81hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
610Cascade CM10boiler81hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
611Cascade CM10boiler81disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
612Cascade CM10boiler81circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
613Cascade CM10boiler81circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
614Cascade CM10boiler81curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
615Cascade CM10boiler81curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
616Cascade CM10boiler81curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
617Cascade CM10boiler81storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
618Cascade CM10boiler81storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
619Cascade CM10boiler81activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
620Cascade CM10boiler81onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
621Cascade CM10boiler81disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
622Cascade CM10boiler81chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
623Cascade CM10boiler81rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
624Cascade CM10boiler81tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
625Cascade CM10boiler81activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
626Cascade CM10boiler813wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
627Cascade CM10boiler81mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
628Cascade CM10boiler81cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
629Cascade CM10boiler81startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
630Cascade CM10boiler81workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
631Cascade CM10boiler81nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
632Cascade CM10boiler81nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
633Cascade CM10boiler81nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
634Cascade CM10boiler81nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
635Logamax Plus GB022boiler84resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
636Logamax Plus GB022boiler84heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
637Logamax Plus GB022boiler84heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
638Logamax Plus GB022boiler84tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
639Logamax Plus GB022boiler84selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
640Logamax Plus GB022boiler84heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
641Logamax Plus GB022boiler84outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
642Logamax Plus GB022boiler84curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
643Logamax Plus GB022boiler84rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
644Logamax Plus GB022boiler84switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
645Logamax Plus GB022boiler84syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
646Logamax Plus GB022boiler84boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
647Logamax Plus GB022boiler84headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
648Logamax Plus GB022boiler84exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
649Logamax Plus GB022boiler84burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
650Logamax Plus GB022boiler84burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
651Logamax Plus GB022boiler84flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
652Logamax Plus GB022boiler84fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
653Logamax Plus GB022boiler84ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
654Logamax Plus GB022boiler84oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
655Logamax Plus GB022boiler84burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
656Logamax Plus GB022boiler84burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
657Logamax Plus GB022boiler84burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
658Logamax Plus GB022boiler84absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
659Logamax Plus GB022boiler84heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
660Logamax Plus GB022boiler84boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
661Logamax Plus GB022boiler84boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
662Logamax Plus GB022boiler84boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
663Logamax Plus GB022boiler84boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
664Logamax Plus GB022boiler84curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
665Logamax Plus GB022boiler84curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
666Logamax Plus GB022boiler84curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
667Logamax Plus GB022boiler84summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
668Logamax Plus GB022boiler84nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
669Logamax Plus GB022boiler84nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
670Logamax Plus GB022boiler84heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
671Logamax Plus GB022boiler84heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
672Logamax Plus GB022boiler84heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
673Logamax Plus GB022boiler84pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
674Logamax Plus GB022boiler84pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
675Logamax Plus GB022boiler84pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
676Logamax Plus GB022boiler84pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
677Logamax Plus GB022boiler84pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
678Logamax Plus GB022boiler84selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
679Logamax Plus GB022boiler84curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
680Logamax Plus GB022boiler84burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
681Logamax Plus GB022boiler84burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
682Logamax Plus GB022boiler84burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
683Logamax Plus GB022boiler84heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
684Logamax Plus GB022boiler84heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
685Logamax Plus GB022boiler84ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
686Logamax Plus GB022boiler84lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
687Logamax Plus GB022boiler84servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
688Logamax Plus GB022boiler84servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
689Logamax Plus GB022boiler84maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
690Logamax Plus GB022boiler84maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
691Logamax Plus GB022boiler84maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
692Logamax Plus GB022boiler84maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
693Logamax Plus GB022boiler84emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
694Logamax Plus GB022boiler84emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
695Logamax Plus GB022boiler84meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
696Logamax Plus GB022boiler84metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
697Logamax Plus GB022boiler84gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
698Logamax Plus GB022boiler84gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
699Logamax Plus GB022boiler84nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
700Logamax Plus GB022boiler84nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
701Logamax Plus GB022boiler84tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
702Logamax Plus GB022boiler84settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
703Logamax Plus GB022boiler84seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
704Logamax Plus GB022boiler84seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
705Logamax Plus GB022boiler84tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
706Logamax Plus GB022boiler84seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
707Logamax Plus GB022boiler84seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
708Logamax Plus GB022boiler84solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
709Logamax Plus GB022boiler84typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
710Logamax Plus GB022boiler84comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
711Logamax Plus GB022boiler84comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
712Logamax Plus GB022boiler84flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
713Logamax Plus GB022boiler84chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
714Logamax Plus GB022boiler84maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
715Logamax Plus GB022boiler84maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
716Logamax Plus GB022boiler84circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
717Logamax Plus GB022boiler84chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
718Logamax Plus GB022boiler84hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
719Logamax Plus GB022boiler84hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
720Logamax Plus GB022boiler84disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
721Logamax Plus GB022boiler84circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
722Logamax Plus GB022boiler84circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
723Logamax Plus GB022boiler84curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
724Logamax Plus GB022boiler84curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
725Logamax Plus GB022boiler84curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
726Logamax Plus GB022boiler84storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
727Logamax Plus GB022boiler84storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
728Logamax Plus GB022boiler84activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
729Logamax Plus GB022boiler84onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
730Logamax Plus GB022boiler84disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
731Logamax Plus GB022boiler84chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
732Logamax Plus GB022boiler84rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
733Logamax Plus GB022boiler84tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
734Logamax Plus GB022boiler84activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
735Logamax Plus GB022boiler843wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
736Logamax Plus GB022boiler84mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
737Logamax Plus GB022boiler84cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
738Logamax Plus GB022boiler84startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
739Logamax Plus GB022boiler84workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
740Logamax Plus GB022boiler84nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
741Logamax Plus GB022boiler84nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
742Logamax Plus GB022boiler84nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
743Logamax Plus GB022boiler84nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
744Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
745Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
746Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
747Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
748Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
749Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
750Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
751Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
752Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
753Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
754Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
755Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
756Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
757Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
758Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
759Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
760Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
761Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
762Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
763Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
764Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
765Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
766Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
767Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
768Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
769Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
770Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
771Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
772Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
773Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
774Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
775Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
776Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
777Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
778Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
779Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
780Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
781Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
782Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
783Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
784Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
785Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
786Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
787Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
788Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
789Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
790Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
791Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
792Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
793Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
794Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
795Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
796Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
797Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
798Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
799Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
800Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
801Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
802Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
803Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
804Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
805Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
806Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
807Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
808Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
809Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
810Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
811Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
812Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
813Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
814Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
815Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
816Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
817Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
818Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
819Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
820Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
821Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
822Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
823Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
824Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
825Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
826Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
827Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
828Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
829Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
830Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
831Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
832Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
833Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
834Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
835Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
836Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
837Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
838Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
839Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
840Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
841Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
842Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
843Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
844Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler953wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
845Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
846Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
847Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
848Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
849Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
850Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
851Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
852Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3boiler95nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
853Topline/GB162boiler115resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
854Topline/GB162boiler115heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
855Topline/GB162boiler115heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
856Topline/GB162boiler115tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
857Topline/GB162boiler115selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
858Topline/GB162boiler115heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
859Topline/GB162boiler115outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
860Topline/GB162boiler115curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
861Topline/GB162boiler115rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
862Topline/GB162boiler115switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
863Topline/GB162boiler115syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
864Topline/GB162boiler115boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
865Topline/GB162boiler115headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
866Topline/GB162boiler115exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
867Topline/GB162boiler115burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
868Topline/GB162boiler115burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
869Topline/GB162boiler115flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
870Topline/GB162boiler115fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
871Topline/GB162boiler115ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
872Topline/GB162boiler115oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
873Topline/GB162boiler115burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
874Topline/GB162boiler115burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
875Topline/GB162boiler115burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
876Topline/GB162boiler115absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
877Topline/GB162boiler115heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
878Topline/GB162boiler115boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
879Topline/GB162boiler115boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
880Topline/GB162boiler115boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
881Topline/GB162boiler115boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
882Topline/GB162boiler115curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
883Topline/GB162boiler115curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
884Topline/GB162boiler115curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
885Topline/GB162boiler115summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
886Topline/GB162boiler115nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
887Topline/GB162boiler115nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
888Topline/GB162boiler115heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
889Topline/GB162boiler115heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
890Topline/GB162boiler115heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
891Topline/GB162boiler115pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
892Topline/GB162boiler115pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
893Topline/GB162boiler115pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
894Topline/GB162boiler115pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
895Topline/GB162boiler115pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
896Topline/GB162boiler115selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
897Topline/GB162boiler115curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
898Topline/GB162boiler115burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
899Topline/GB162boiler115burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
900Topline/GB162boiler115burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
901Topline/GB162boiler115heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
902Topline/GB162boiler115heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
903Topline/GB162boiler115ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
904Topline/GB162boiler115lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
905Topline/GB162boiler115servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
906Topline/GB162boiler115servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
907Topline/GB162boiler115maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
908Topline/GB162boiler115maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
909Topline/GB162boiler115maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
910Topline/GB162boiler115maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
911Topline/GB162boiler115emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
912Topline/GB162boiler115emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
913Topline/GB162boiler115meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
914Topline/GB162boiler115metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
915Topline/GB162boiler115gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
916Topline/GB162boiler115gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
917Topline/GB162boiler115nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
918Topline/GB162boiler115nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
919Topline/GB162boiler115tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
920Topline/GB162boiler115settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
921Topline/GB162boiler115seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
922Topline/GB162boiler115seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
923Topline/GB162boiler115tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
924Topline/GB162boiler115seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
925Topline/GB162boiler115seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
926Topline/GB162boiler115solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
927Topline/GB162boiler115typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
928Topline/GB162boiler115comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
929Topline/GB162boiler115comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
930Topline/GB162boiler115flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
931Topline/GB162boiler115chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
932Topline/GB162boiler115maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
933Topline/GB162boiler115maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
934Topline/GB162boiler115circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
935Topline/GB162boiler115chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
936Topline/GB162boiler115hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
937Topline/GB162boiler115hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
938Topline/GB162boiler115disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
939Topline/GB162boiler115circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
940Topline/GB162boiler115circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
941Topline/GB162boiler115curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
942Topline/GB162boiler115curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
943Topline/GB162boiler115curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
944Topline/GB162boiler115storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
945Topline/GB162boiler115storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
946Topline/GB162boiler115activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
947Topline/GB162boiler115onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
948Topline/GB162boiler115disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
949Topline/GB162boiler115chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
950Topline/GB162boiler115rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
951Topline/GB162boiler115tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
952Topline/GB162boiler115activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
953Topline/GB162boiler1153wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
954Topline/GB162boiler115mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
955Topline/GB162boiler115cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
956Topline/GB162boiler115startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
957Topline/GB162boiler115workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
958Topline/GB162boiler115nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
959Topline/GB162boiler115nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
960Topline/GB162boiler115nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
961Topline/GB162boiler115nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
962Cascade MCM10boiler121resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
963Cascade MCM10boiler121heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
964Cascade MCM10boiler121heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
965Cascade MCM10boiler121tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
966Cascade MCM10boiler121selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
967Cascade MCM10boiler121heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
968Cascade MCM10boiler121outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
969Cascade MCM10boiler121curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
970Cascade MCM10boiler121rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
971Cascade MCM10boiler121switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
972Cascade MCM10boiler121syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
973Cascade MCM10boiler121boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
974Cascade MCM10boiler121headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
975Cascade MCM10boiler121exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
976Cascade MCM10boiler121burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
977Cascade MCM10boiler121burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
978Cascade MCM10boiler121flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
979Cascade MCM10boiler121fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
980Cascade MCM10boiler121ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
981Cascade MCM10boiler121oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
982Cascade MCM10boiler121burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
983Cascade MCM10boiler121burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
984Cascade MCM10boiler121burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
985Cascade MCM10boiler121absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
986Cascade MCM10boiler121heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
987Cascade MCM10boiler121boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
988Cascade MCM10boiler121boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
989Cascade MCM10boiler121boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
990Cascade MCM10boiler121boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
991Cascade MCM10boiler121curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
992Cascade MCM10boiler121curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
993Cascade MCM10boiler121curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
994Cascade MCM10boiler121summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
995Cascade MCM10boiler121nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
996Cascade MCM10boiler121nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
997Cascade MCM10boiler121heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
998Cascade MCM10boiler121heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
999Cascade MCM10boiler121heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1000Cascade MCM10boiler121pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1001Cascade MCM10boiler121pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1002Cascade MCM10boiler121pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1003Cascade MCM10boiler121pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1004Cascade MCM10boiler121pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1005Cascade MCM10boiler121selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
1006Cascade MCM10boiler121curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
1007Cascade MCM10boiler121burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
1008Cascade MCM10boiler121burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
1009Cascade MCM10boiler121burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
1010Cascade MCM10boiler121heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
1011Cascade MCM10boiler121heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
1012Cascade MCM10boiler121ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
1013Cascade MCM10boiler121lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
1014Cascade MCM10boiler121servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
1015Cascade MCM10boiler121servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
1016Cascade MCM10boiler121maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
1017Cascade MCM10boiler121maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
1018Cascade MCM10boiler121maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
1019Cascade MCM10boiler121maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
1020Cascade MCM10boiler121emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
1021Cascade MCM10boiler121emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
1022Cascade MCM10boiler121meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
1023Cascade MCM10boiler121metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1024Cascade MCM10boiler121gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
1025Cascade MCM10boiler121gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1026Cascade MCM10boiler121nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
1027Cascade MCM10boiler121nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1028Cascade MCM10boiler121tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1029Cascade MCM10boiler121settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1030Cascade MCM10boiler121seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1031Cascade MCM10boiler121seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1032Cascade MCM10boiler121tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1033Cascade MCM10boiler121seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1034Cascade MCM10boiler121seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1035Cascade MCM10boiler121solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1036Cascade MCM10boiler121typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1037Cascade MCM10boiler121comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1038Cascade MCM10boiler121comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1039Cascade MCM10boiler121flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1040Cascade MCM10boiler121chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1041Cascade MCM10boiler121maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1042Cascade MCM10boiler121maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1043Cascade MCM10boiler121circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1044Cascade MCM10boiler121chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1045Cascade MCM10boiler121hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1046Cascade MCM10boiler121hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1047Cascade MCM10boiler121disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1048Cascade MCM10boiler121circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1049Cascade MCM10boiler121circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1050Cascade MCM10boiler121curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1051Cascade MCM10boiler121curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1052Cascade MCM10boiler121curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1053Cascade MCM10boiler121storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1054Cascade MCM10boiler121storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1055Cascade MCM10boiler121activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1056Cascade MCM10boiler121onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1057Cascade MCM10boiler121disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1058Cascade MCM10boiler121chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1059Cascade MCM10boiler121rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1060Cascade MCM10boiler121tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1061Cascade MCM10boiler121activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1062Cascade MCM10boiler1213wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1063Cascade MCM10boiler121mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1064Cascade MCM10boiler121cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1065Cascade MCM10boiler121startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1066Cascade MCM10boiler121workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1067Cascade MCM10boiler121nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
1068Cascade MCM10boiler121nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
1069Cascade MCM10boiler121nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
1070Cascade MCM10boiler121nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1071Prolineboiler122resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1072Prolineboiler122heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1073Prolineboiler122heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1074Prolineboiler122tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1075Prolineboiler122selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1076Prolineboiler122heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1077Prolineboiler122outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1078Prolineboiler122curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1079Prolineboiler122rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1080Prolineboiler122switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1081Prolineboiler122syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1082Prolineboiler122boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1083Prolineboiler122headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1084Prolineboiler122exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
1085Prolineboiler122burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
1086Prolineboiler122burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
1087Prolineboiler122flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
1088Prolineboiler122fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
1089Prolineboiler122ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
1090Prolineboiler122oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
1091Prolineboiler122burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
1092Prolineboiler122burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
1093Prolineboiler122burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
1094Prolineboiler122absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
1095Prolineboiler122heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
1096Prolineboiler122boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
1097Prolineboiler122boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
1098Prolineboiler122boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
1099Prolineboiler122boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
1100Prolineboiler122curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
1101Prolineboiler122curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
1102Prolineboiler122curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
1103Prolineboiler122summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
1104Prolineboiler122nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
1105Prolineboiler122nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
1106Prolineboiler122heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1107Prolineboiler122heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1108Prolineboiler122heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1109Prolineboiler122pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1110Prolineboiler122pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1111Prolineboiler122pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1112Prolineboiler122pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1113Prolineboiler122pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1114Prolineboiler122selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
1115Prolineboiler122curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
1116Prolineboiler122burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
1117Prolineboiler122burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
1118Prolineboiler122burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
1119Prolineboiler122heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
1120Prolineboiler122heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
1121Prolineboiler122ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
1122Prolineboiler122lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
1123Prolineboiler122servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
1124Prolineboiler122servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
1125Prolineboiler122maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
1126Prolineboiler122maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
1127Prolineboiler122maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
1128Prolineboiler122maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
1129Prolineboiler122emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
1130Prolineboiler122emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
1131Prolineboiler122meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
1132Prolineboiler122metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1133Prolineboiler122gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
1134Prolineboiler122gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1135Prolineboiler122nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
1136Prolineboiler122nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1137Prolineboiler122tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1138Prolineboiler122settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1139Prolineboiler122seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1140Prolineboiler122seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1141Prolineboiler122tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1142Prolineboiler122seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1143Prolineboiler122seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1144Prolineboiler122solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1145Prolineboiler122typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1146Prolineboiler122comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1147Prolineboiler122comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1148Prolineboiler122flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1149Prolineboiler122chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1150Prolineboiler122maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1151Prolineboiler122maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1152Prolineboiler122circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1153Prolineboiler122chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1154Prolineboiler122hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1155Prolineboiler122hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1156Prolineboiler122disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1157Prolineboiler122circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1158Prolineboiler122circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1159Prolineboiler122curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1160Prolineboiler122curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1161Prolineboiler122curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1162Prolineboiler122storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1163Prolineboiler122storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1164Prolineboiler122activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1165Prolineboiler122onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1166Prolineboiler122disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1167Prolineboiler122chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1168Prolineboiler122rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1169Prolineboiler122tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1170Prolineboiler122activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1171Prolineboiler1223wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1172Prolineboiler122mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1173Prolineboiler122cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1174Prolineboiler122startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1175Prolineboiler122workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1176Prolineboiler122nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
1177Prolineboiler122nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
1178Prolineboiler122nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
1179Prolineboiler122nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1180GBx72/Trendline/Cerapur/Greenstar Siboiler123resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1181GBx72/Trendline/Cerapur/Greenstar Siboiler123heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1182GBx72/Trendline/Cerapur/Greenstar Siboiler123heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1183GBx72/Trendline/Cerapur/Greenstar Siboiler123tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1184GBx72/Trendline/Cerapur/Greenstar Siboiler123selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1185GBx72/Trendline/Cerapur/Greenstar Siboiler123heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1186GBx72/Trendline/Cerapur/Greenstar Siboiler123outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1187GBx72/Trendline/Cerapur/Greenstar Siboiler123curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1188GBx72/Trendline/Cerapur/Greenstar Siboiler123rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1189GBx72/Trendline/Cerapur/Greenstar Siboiler123switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1190GBx72/Trendline/Cerapur/Greenstar Siboiler123syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1191GBx72/Trendline/Cerapur/Greenstar Siboiler123boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1192GBx72/Trendline/Cerapur/Greenstar Siboiler123headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1193GBx72/Trendline/Cerapur/Greenstar Siboiler123exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
1194GBx72/Trendline/Cerapur/Greenstar Siboiler123burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
1195GBx72/Trendline/Cerapur/Greenstar Siboiler123burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
1196GBx72/Trendline/Cerapur/Greenstar Siboiler123flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
1197GBx72/Trendline/Cerapur/Greenstar Siboiler123fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
1198GBx72/Trendline/Cerapur/Greenstar Siboiler123ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
1199GBx72/Trendline/Cerapur/Greenstar Siboiler123oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
1200GBx72/Trendline/Cerapur/Greenstar Siboiler123burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
1201GBx72/Trendline/Cerapur/Greenstar Siboiler123burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
1202GBx72/Trendline/Cerapur/Greenstar Siboiler123burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
1203GBx72/Trendline/Cerapur/Greenstar Siboiler123absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
1204GBx72/Trendline/Cerapur/Greenstar Siboiler123heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
1205GBx72/Trendline/Cerapur/Greenstar Siboiler123boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
1206GBx72/Trendline/Cerapur/Greenstar Siboiler123boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
1207GBx72/Trendline/Cerapur/Greenstar Siboiler123boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
1208GBx72/Trendline/Cerapur/Greenstar Siboiler123boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
1209GBx72/Trendline/Cerapur/Greenstar Siboiler123curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
1210GBx72/Trendline/Cerapur/Greenstar Siboiler123curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
1211GBx72/Trendline/Cerapur/Greenstar Siboiler123curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
1212GBx72/Trendline/Cerapur/Greenstar Siboiler123summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
1213GBx72/Trendline/Cerapur/Greenstar Siboiler123nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
1214GBx72/Trendline/Cerapur/Greenstar Siboiler123nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
1215GBx72/Trendline/Cerapur/Greenstar Siboiler123heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1216GBx72/Trendline/Cerapur/Greenstar Siboiler123heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1217GBx72/Trendline/Cerapur/Greenstar Siboiler123heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1218GBx72/Trendline/Cerapur/Greenstar Siboiler123pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1219GBx72/Trendline/Cerapur/Greenstar Siboiler123pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1220GBx72/Trendline/Cerapur/Greenstar Siboiler123pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1221GBx72/Trendline/Cerapur/Greenstar Siboiler123pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1222GBx72/Trendline/Cerapur/Greenstar Siboiler123pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1223GBx72/Trendline/Cerapur/Greenstar Siboiler123selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
1224GBx72/Trendline/Cerapur/Greenstar Siboiler123curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
1225GBx72/Trendline/Cerapur/Greenstar Siboiler123burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
1226GBx72/Trendline/Cerapur/Greenstar Siboiler123burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
1227GBx72/Trendline/Cerapur/Greenstar Siboiler123burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
1228GBx72/Trendline/Cerapur/Greenstar Siboiler123heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
1229GBx72/Trendline/Cerapur/Greenstar Siboiler123heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
1230GBx72/Trendline/Cerapur/Greenstar Siboiler123ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
1231GBx72/Trendline/Cerapur/Greenstar Siboiler123lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
1232GBx72/Trendline/Cerapur/Greenstar Siboiler123servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
1233GBx72/Trendline/Cerapur/Greenstar Siboiler123servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
1234GBx72/Trendline/Cerapur/Greenstar Siboiler123maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
1235GBx72/Trendline/Cerapur/Greenstar Siboiler123maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
1236GBx72/Trendline/Cerapur/Greenstar Siboiler123maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
1237GBx72/Trendline/Cerapur/Greenstar Siboiler123maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
1238GBx72/Trendline/Cerapur/Greenstar Siboiler123emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
1239GBx72/Trendline/Cerapur/Greenstar Siboiler123emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
1240GBx72/Trendline/Cerapur/Greenstar Siboiler123meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
1241GBx72/Trendline/Cerapur/Greenstar Siboiler123metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1242GBx72/Trendline/Cerapur/Greenstar Siboiler123gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
1243GBx72/Trendline/Cerapur/Greenstar Siboiler123gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1244GBx72/Trendline/Cerapur/Greenstar Siboiler123nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
1245GBx72/Trendline/Cerapur/Greenstar Siboiler123nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1246GBx72/Trendline/Cerapur/Greenstar Siboiler123tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1247GBx72/Trendline/Cerapur/Greenstar Siboiler123settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1248GBx72/Trendline/Cerapur/Greenstar Siboiler123seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1249GBx72/Trendline/Cerapur/Greenstar Siboiler123seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1250GBx72/Trendline/Cerapur/Greenstar Siboiler123tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1251GBx72/Trendline/Cerapur/Greenstar Siboiler123seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1252GBx72/Trendline/Cerapur/Greenstar Siboiler123seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1253GBx72/Trendline/Cerapur/Greenstar Siboiler123solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1254GBx72/Trendline/Cerapur/Greenstar Siboiler123typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1255GBx72/Trendline/Cerapur/Greenstar Siboiler123comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1256GBx72/Trendline/Cerapur/Greenstar Siboiler123comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1257GBx72/Trendline/Cerapur/Greenstar Siboiler123flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1258GBx72/Trendline/Cerapur/Greenstar Siboiler123chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1259GBx72/Trendline/Cerapur/Greenstar Siboiler123maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1260GBx72/Trendline/Cerapur/Greenstar Siboiler123maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1261GBx72/Trendline/Cerapur/Greenstar Siboiler123circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1262GBx72/Trendline/Cerapur/Greenstar Siboiler123chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1263GBx72/Trendline/Cerapur/Greenstar Siboiler123hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1264GBx72/Trendline/Cerapur/Greenstar Siboiler123hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1265GBx72/Trendline/Cerapur/Greenstar Siboiler123disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1266GBx72/Trendline/Cerapur/Greenstar Siboiler123circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1267GBx72/Trendline/Cerapur/Greenstar Siboiler123circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1268GBx72/Trendline/Cerapur/Greenstar Siboiler123curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1269GBx72/Trendline/Cerapur/Greenstar Siboiler123curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1270GBx72/Trendline/Cerapur/Greenstar Siboiler123curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1271GBx72/Trendline/Cerapur/Greenstar Siboiler123storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1272GBx72/Trendline/Cerapur/Greenstar Siboiler123storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1273GBx72/Trendline/Cerapur/Greenstar Siboiler123activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1274GBx72/Trendline/Cerapur/Greenstar Siboiler123onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1275GBx72/Trendline/Cerapur/Greenstar Siboiler123disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1276GBx72/Trendline/Cerapur/Greenstar Siboiler123chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1277GBx72/Trendline/Cerapur/Greenstar Siboiler123rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1278GBx72/Trendline/Cerapur/Greenstar Siboiler123tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1279GBx72/Trendline/Cerapur/Greenstar Siboiler123activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1280GBx72/Trendline/Cerapur/Greenstar Siboiler1233wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1281GBx72/Trendline/Cerapur/Greenstar Siboiler123mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1282GBx72/Trendline/Cerapur/Greenstar Siboiler123cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1283GBx72/Trendline/Cerapur/Greenstar Siboiler123startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1284GBx72/Trendline/Cerapur/Greenstar Siboiler123workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1285GBx72/Trendline/Cerapur/Greenstar Siboiler123nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
1286GBx72/Trendline/Cerapur/Greenstar Siboiler123nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
1287GBx72/Trendline/Cerapur/Greenstar Siboiler123nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
1288GBx72/Trendline/Cerapur/Greenstar Siboiler123nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1289GB212boiler131resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1290GB212boiler131heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1291GB212boiler131heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1292GB212boiler131tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1293GB212boiler131selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1294GB212boiler131heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1295GB212boiler131outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1296GB212boiler131curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1297GB212boiler131rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1298GB212boiler131switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1299GB212boiler131syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1300GB212boiler131boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1301GB212boiler131headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1302GB212boiler131exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
1303GB212boiler131burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
1304GB212boiler131burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
1305GB212boiler131flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
1306GB212boiler131fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
1307GB212boiler131ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
1308GB212boiler131oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
1309GB212boiler131burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
1310GB212boiler131burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
1311GB212boiler131burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
1312GB212boiler131absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
1313GB212boiler131heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
1314GB212boiler131boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
1315GB212boiler131boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
1316GB212boiler131boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
1317GB212boiler131boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
1318GB212boiler131curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
1319GB212boiler131curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
1320GB212boiler131curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
1321GB212boiler131summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
1322GB212boiler131nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
1323GB212boiler131nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
1324GB212boiler131heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1325GB212boiler131heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1326GB212boiler131heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1327GB212boiler131pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1328GB212boiler131pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1329GB212boiler131pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1330GB212boiler131pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1331GB212boiler131pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1332GB212boiler131selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
1333GB212boiler131curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
1334GB212boiler131burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
1335GB212boiler131burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
1336GB212boiler131burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
1337GB212boiler131heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
1338GB212boiler131heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
1339GB212boiler131ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
1340GB212boiler131lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
1341GB212boiler131servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
1342GB212boiler131servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
1343GB212boiler131maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
1344GB212boiler131maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
1345GB212boiler131maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
1346GB212boiler131maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
1347GB212boiler131emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
1348GB212boiler131emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
1349GB212boiler131meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
1350GB212boiler131metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1351GB212boiler131gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
1352GB212boiler131gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1353GB212boiler131nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
1354GB212boiler131nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1355GB212boiler131tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1356GB212boiler131settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1357GB212boiler131seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1358GB212boiler131seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1359GB212boiler131tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1360GB212boiler131seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1361GB212boiler131seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1362GB212boiler131solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1363GB212boiler131typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1364GB212boiler131comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1365GB212boiler131comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1366GB212boiler131flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1367GB212boiler131chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1368GB212boiler131maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1369GB212boiler131maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1370GB212boiler131circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1371GB212boiler131chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1372GB212boiler131hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1373GB212boiler131hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1374GB212boiler131disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1375GB212boiler131circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1376GB212boiler131circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1377GB212boiler131curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1378GB212boiler131curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1379GB212boiler131curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1380GB212boiler131storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1381GB212boiler131storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1382GB212boiler131activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1383GB212boiler131onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1384GB212boiler131disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1385GB212boiler131chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1386GB212boiler131rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1387GB212boiler131tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1388GB212boiler131activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1389GB212boiler1313wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1390GB212boiler131mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1391GB212boiler131cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1392GB212boiler131startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1393GB212boiler131workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1394GB212boiler131nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
1395GB212boiler131nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
1396GB212boiler131nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
1397GB212boiler131nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1398GC7000Fboiler132resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1399GC7000Fboiler132heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1400GC7000Fboiler132heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1401GC7000Fboiler132tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1402GC7000Fboiler132selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1403GC7000Fboiler132heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1404GC7000Fboiler132outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1405GC7000Fboiler132curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1406GC7000Fboiler132rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1407GC7000Fboiler132switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1408GC7000Fboiler132syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1409GC7000Fboiler132boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1410GC7000Fboiler132headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1411GC7000Fboiler132exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
1412GC7000Fboiler132burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
1413GC7000Fboiler132burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
1414GC7000Fboiler132flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
1415GC7000Fboiler132fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
1416GC7000Fboiler132ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
1417GC7000Fboiler132oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
1418GC7000Fboiler132burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
1419GC7000Fboiler132burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
1420GC7000Fboiler132burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
1421GC7000Fboiler132absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
1422GC7000Fboiler132heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
1423GC7000Fboiler132boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
1424GC7000Fboiler132boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
1425GC7000Fboiler132boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
1426GC7000Fboiler132boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
1427GC7000Fboiler132curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
1428GC7000Fboiler132curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
1429GC7000Fboiler132curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
1430GC7000Fboiler132summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
1431GC7000Fboiler132nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
1432GC7000Fboiler132nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
1433GC7000Fboiler132heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1434GC7000Fboiler132heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1435GC7000Fboiler132heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1436GC7000Fboiler132pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1437GC7000Fboiler132pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1438GC7000Fboiler132pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1439GC7000Fboiler132pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1440GC7000Fboiler132pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1441GC7000Fboiler132selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
1442GC7000Fboiler132curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
1443GC7000Fboiler132burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
1444GC7000Fboiler132burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
1445GC7000Fboiler132burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
1446GC7000Fboiler132heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
1447GC7000Fboiler132heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
1448GC7000Fboiler132ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
1449GC7000Fboiler132lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
1450GC7000Fboiler132servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
1451GC7000Fboiler132servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
1452GC7000Fboiler132maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
1453GC7000Fboiler132maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
1454GC7000Fboiler132maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
1455GC7000Fboiler132maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
1456GC7000Fboiler132emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
1457GC7000Fboiler132emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
1458GC7000Fboiler132meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
1459GC7000Fboiler132metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1460GC7000Fboiler132gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
1461GC7000Fboiler132gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1462GC7000Fboiler132nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
1463GC7000Fboiler132nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1464GC7000Fboiler132tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1465GC7000Fboiler132settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1466GC7000Fboiler132seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1467GC7000Fboiler132seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1468GC7000Fboiler132tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1469GC7000Fboiler132seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1470GC7000Fboiler132seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1471GC7000Fboiler132solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1472GC7000Fboiler132typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1473GC7000Fboiler132comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1474GC7000Fboiler132comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1475GC7000Fboiler132flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1476GC7000Fboiler132chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1477GC7000Fboiler132maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1478GC7000Fboiler132maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1479GC7000Fboiler132circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1480GC7000Fboiler132chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1481GC7000Fboiler132hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1482GC7000Fboiler132hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1483GC7000Fboiler132disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1484GC7000Fboiler132circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1485GC7000Fboiler132circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1486GC7000Fboiler132curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1487GC7000Fboiler132curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1488GC7000Fboiler132curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1489GC7000Fboiler132storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1490GC7000Fboiler132storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1491GC7000Fboiler132activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1492GC7000Fboiler132onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1493GC7000Fboiler132disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1494GC7000Fboiler132chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1495GC7000Fboiler132rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1496GC7000Fboiler132tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1497GC7000Fboiler132activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1498GC7000Fboiler1323wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1499GC7000Fboiler132mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1500GC7000Fboiler132cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1501GC7000Fboiler132startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1502GC7000Fboiler132workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1503GC7000Fboiler132nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
1504GC7000Fboiler132nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
1505GC7000Fboiler132nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
1506GC7000Fboiler132nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1507Logano GB125/KB195i/Logamatic MC110boiler133resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1508Logano GB125/KB195i/Logamatic MC110boiler133heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1509Logano GB125/KB195i/Logamatic MC110boiler133heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1510Logano GB125/KB195i/Logamatic MC110boiler133tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1511Logano GB125/KB195i/Logamatic MC110boiler133selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1512Logano GB125/KB195i/Logamatic MC110boiler133heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1513Logano GB125/KB195i/Logamatic MC110boiler133outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1514Logano GB125/KB195i/Logamatic MC110boiler133curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1515Logano GB125/KB195i/Logamatic MC110boiler133rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1516Logano GB125/KB195i/Logamatic MC110boiler133switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1517Logano GB125/KB195i/Logamatic MC110boiler133syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1518Logano GB125/KB195i/Logamatic MC110boiler133boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1519Logano GB125/KB195i/Logamatic MC110boiler133headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1520Logano GB125/KB195i/Logamatic MC110boiler133exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
1521Logano GB125/KB195i/Logamatic MC110boiler133burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
1522Logano GB125/KB195i/Logamatic MC110boiler133burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
1523Logano GB125/KB195i/Logamatic MC110boiler133flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
1524Logano GB125/KB195i/Logamatic MC110boiler133fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
1525Logano GB125/KB195i/Logamatic MC110boiler133ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
1526Logano GB125/KB195i/Logamatic MC110boiler133oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
1527Logano GB125/KB195i/Logamatic MC110boiler133burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
1528Logano GB125/KB195i/Logamatic MC110boiler133burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
1529Logano GB125/KB195i/Logamatic MC110boiler133burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
1530Logano GB125/KB195i/Logamatic MC110boiler133absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
1531Logano GB125/KB195i/Logamatic MC110boiler133heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
1532Logano GB125/KB195i/Logamatic MC110boiler133boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
1533Logano GB125/KB195i/Logamatic MC110boiler133boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
1534Logano GB125/KB195i/Logamatic MC110boiler133boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
1535Logano GB125/KB195i/Logamatic MC110boiler133boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
1536Logano GB125/KB195i/Logamatic MC110boiler133curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
1537Logano GB125/KB195i/Logamatic MC110boiler133curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
1538Logano GB125/KB195i/Logamatic MC110boiler133curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
1539Logano GB125/KB195i/Logamatic MC110boiler133summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
1540Logano GB125/KB195i/Logamatic MC110boiler133nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
1541Logano GB125/KB195i/Logamatic MC110boiler133nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
1542Logano GB125/KB195i/Logamatic MC110boiler133heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1543Logano GB125/KB195i/Logamatic MC110boiler133heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1544Logano GB125/KB195i/Logamatic MC110boiler133heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1545Logano GB125/KB195i/Logamatic MC110boiler133pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1546Logano GB125/KB195i/Logamatic MC110boiler133pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1547Logano GB125/KB195i/Logamatic MC110boiler133pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1548Logano GB125/KB195i/Logamatic MC110boiler133pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1549Logano GB125/KB195i/Logamatic MC110boiler133pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1550Logano GB125/KB195i/Logamatic MC110boiler133selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
1551Logano GB125/KB195i/Logamatic MC110boiler133curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
1552Logano GB125/KB195i/Logamatic MC110boiler133burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
1553Logano GB125/KB195i/Logamatic MC110boiler133burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
1554Logano GB125/KB195i/Logamatic MC110boiler133burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
1555Logano GB125/KB195i/Logamatic MC110boiler133heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
1556Logano GB125/KB195i/Logamatic MC110boiler133heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
1557Logano GB125/KB195i/Logamatic MC110boiler133ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
1558Logano GB125/KB195i/Logamatic MC110boiler133lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
1559Logano GB125/KB195i/Logamatic MC110boiler133servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
1560Logano GB125/KB195i/Logamatic MC110boiler133servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
1561Logano GB125/KB195i/Logamatic MC110boiler133maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
1562Logano GB125/KB195i/Logamatic MC110boiler133maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
1563Logano GB125/KB195i/Logamatic MC110boiler133maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
1564Logano GB125/KB195i/Logamatic MC110boiler133maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
1565Logano GB125/KB195i/Logamatic MC110boiler133emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
1566Logano GB125/KB195i/Logamatic MC110boiler133emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
1567Logano GB125/KB195i/Logamatic MC110boiler133meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
1568Logano GB125/KB195i/Logamatic MC110boiler133metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1569Logano GB125/KB195i/Logamatic MC110boiler133gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
1570Logano GB125/KB195i/Logamatic MC110boiler133gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1571Logano GB125/KB195i/Logamatic MC110boiler133nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
1572Logano GB125/KB195i/Logamatic MC110boiler133nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1573Logano GB125/KB195i/Logamatic MC110boiler133tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1574Logano GB125/KB195i/Logamatic MC110boiler133settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1575Logano GB125/KB195i/Logamatic MC110boiler133seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1576Logano GB125/KB195i/Logamatic MC110boiler133seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1577Logano GB125/KB195i/Logamatic MC110boiler133tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1578Logano GB125/KB195i/Logamatic MC110boiler133seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1579Logano GB125/KB195i/Logamatic MC110boiler133seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1580Logano GB125/KB195i/Logamatic MC110boiler133solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1581Logano GB125/KB195i/Logamatic MC110boiler133typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1582Logano GB125/KB195i/Logamatic MC110boiler133comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1583Logano GB125/KB195i/Logamatic MC110boiler133comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1584Logano GB125/KB195i/Logamatic MC110boiler133flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1585Logano GB125/KB195i/Logamatic MC110boiler133chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1586Logano GB125/KB195i/Logamatic MC110boiler133maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1587Logano GB125/KB195i/Logamatic MC110boiler133maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1588Logano GB125/KB195i/Logamatic MC110boiler133circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1589Logano GB125/KB195i/Logamatic MC110boiler133chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1590Logano GB125/KB195i/Logamatic MC110boiler133hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1591Logano GB125/KB195i/Logamatic MC110boiler133hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1592Logano GB125/KB195i/Logamatic MC110boiler133disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1593Logano GB125/KB195i/Logamatic MC110boiler133circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1594Logano GB125/KB195i/Logamatic MC110boiler133circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1595Logano GB125/KB195i/Logamatic MC110boiler133curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1596Logano GB125/KB195i/Logamatic MC110boiler133curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1597Logano GB125/KB195i/Logamatic MC110boiler133curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1598Logano GB125/KB195i/Logamatic MC110boiler133storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1599Logano GB125/KB195i/Logamatic MC110boiler133storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1600Logano GB125/KB195i/Logamatic MC110boiler133activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1601Logano GB125/KB195i/Logamatic MC110boiler133onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1602Logano GB125/KB195i/Logamatic MC110boiler133disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1603Logano GB125/KB195i/Logamatic MC110boiler133chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1604Logano GB125/KB195i/Logamatic MC110boiler133rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1605Logano GB125/KB195i/Logamatic MC110boiler133tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1606Logano GB125/KB195i/Logamatic MC110boiler133activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1607Logano GB125/KB195i/Logamatic MC110boiler1333wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1608Logano GB125/KB195i/Logamatic MC110boiler133mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1609Logano GB125/KB195i/Logamatic MC110boiler133cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1610Logano GB125/KB195i/Logamatic MC110boiler133startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1611Logano GB125/KB195i/Logamatic MC110boiler133workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1612Logano GB125/KB195i/Logamatic MC110boiler133nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
1613Logano GB125/KB195i/Logamatic MC110boiler133nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
1614Logano GB125/KB195i/Logamatic MC110boiler133nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
1615Logano GB125/KB195i/Logamatic MC110boiler133nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1616Greenstar 30Ri Compactboiler154resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1617Greenstar 30Ri Compactboiler154heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1618Greenstar 30Ri Compactboiler154heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1619Greenstar 30Ri Compactboiler154tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1620Greenstar 30Ri Compactboiler154selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1621Greenstar 30Ri Compactboiler154heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1622Greenstar 30Ri Compactboiler154outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1623Greenstar 30Ri Compactboiler154curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1624Greenstar 30Ri Compactboiler154rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1625Greenstar 30Ri Compactboiler154switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1626Greenstar 30Ri Compactboiler154syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1627Greenstar 30Ri Compactboiler154boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1628Greenstar 30Ri Compactboiler154headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1629Greenstar 30Ri Compactboiler154exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
1630Greenstar 30Ri Compactboiler154burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
1631Greenstar 30Ri Compactboiler154burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
1632Greenstar 30Ri Compactboiler154flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
1633Greenstar 30Ri Compactboiler154fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
1634Greenstar 30Ri Compactboiler154ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
1635Greenstar 30Ri Compactboiler154oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
1636Greenstar 30Ri Compactboiler154burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
1637Greenstar 30Ri Compactboiler154burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
1638Greenstar 30Ri Compactboiler154burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
1639Greenstar 30Ri Compactboiler154absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
1640Greenstar 30Ri Compactboiler154heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
1641Greenstar 30Ri Compactboiler154boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
1642Greenstar 30Ri Compactboiler154boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
1643Greenstar 30Ri Compactboiler154boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
1644Greenstar 30Ri Compactboiler154boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
1645Greenstar 30Ri Compactboiler154curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
1646Greenstar 30Ri Compactboiler154curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
1647Greenstar 30Ri Compactboiler154curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
1648Greenstar 30Ri Compactboiler154summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
1649Greenstar 30Ri Compactboiler154nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
1650Greenstar 30Ri Compactboiler154nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
1651Greenstar 30Ri Compactboiler154heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1652Greenstar 30Ri Compactboiler154heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1653Greenstar 30Ri Compactboiler154heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1654Greenstar 30Ri Compactboiler154pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1655Greenstar 30Ri Compactboiler154pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1656Greenstar 30Ri Compactboiler154pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1657Greenstar 30Ri Compactboiler154pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1658Greenstar 30Ri Compactboiler154pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1659Greenstar 30Ri Compactboiler154selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
1660Greenstar 30Ri Compactboiler154curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
1661Greenstar 30Ri Compactboiler154burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
1662Greenstar 30Ri Compactboiler154burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
1663Greenstar 30Ri Compactboiler154burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
1664Greenstar 30Ri Compactboiler154heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
1665Greenstar 30Ri Compactboiler154heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
1666Greenstar 30Ri Compactboiler154ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
1667Greenstar 30Ri Compactboiler154lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
1668Greenstar 30Ri Compactboiler154servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
1669Greenstar 30Ri Compactboiler154servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
1670Greenstar 30Ri Compactboiler154maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
1671Greenstar 30Ri Compactboiler154maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
1672Greenstar 30Ri Compactboiler154maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
1673Greenstar 30Ri Compactboiler154maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
1674Greenstar 30Ri Compactboiler154emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
1675Greenstar 30Ri Compactboiler154emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
1676Greenstar 30Ri Compactboiler154meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
1677Greenstar 30Ri Compactboiler154metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1678Greenstar 30Ri Compactboiler154gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
1679Greenstar 30Ri Compactboiler154gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1680Greenstar 30Ri Compactboiler154nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
1681Greenstar 30Ri Compactboiler154nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1682Greenstar 30Ri Compactboiler154tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1683Greenstar 30Ri Compactboiler154settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1684Greenstar 30Ri Compactboiler154seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1685Greenstar 30Ri Compactboiler154seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1686Greenstar 30Ri Compactboiler154tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1687Greenstar 30Ri Compactboiler154seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1688Greenstar 30Ri Compactboiler154seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1689Greenstar 30Ri Compactboiler154solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1690Greenstar 30Ri Compactboiler154typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1691Greenstar 30Ri Compactboiler154comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1692Greenstar 30Ri Compactboiler154comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1693Greenstar 30Ri Compactboiler154flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1694Greenstar 30Ri Compactboiler154chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1695Greenstar 30Ri Compactboiler154maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1696Greenstar 30Ri Compactboiler154maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1697Greenstar 30Ri Compactboiler154circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1698Greenstar 30Ri Compactboiler154chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1699Greenstar 30Ri Compactboiler154hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1700Greenstar 30Ri Compactboiler154hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1701Greenstar 30Ri Compactboiler154disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1702Greenstar 30Ri Compactboiler154circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1703Greenstar 30Ri Compactboiler154circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1704Greenstar 30Ri Compactboiler154curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1705Greenstar 30Ri Compactboiler154curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1706Greenstar 30Ri Compactboiler154curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1707Greenstar 30Ri Compactboiler154storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1708Greenstar 30Ri Compactboiler154storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1709Greenstar 30Ri Compactboiler154activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1710Greenstar 30Ri Compactboiler154onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1711Greenstar 30Ri Compactboiler154disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1712Greenstar 30Ri Compactboiler154chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1713Greenstar 30Ri Compactboiler154rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1714Greenstar 30Ri Compactboiler154tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1715Greenstar 30Ri Compactboiler154activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1716Greenstar 30Ri Compactboiler1543wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1717Greenstar 30Ri Compactboiler154mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1718Greenstar 30Ri Compactboiler154cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1719Greenstar 30Ri Compactboiler154startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1720Greenstar 30Ri Compactboiler154workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1721Greenstar 30Ri Compactboiler154nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
1722Greenstar 30Ri Compactboiler154nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
1723Greenstar 30Ri Compactboiler154nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
1724Greenstar 30Ri Compactboiler154nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1725Cerapur Aeroboiler167resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1726Cerapur Aeroboiler167heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1727Cerapur Aeroboiler167heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1728Cerapur Aeroboiler167tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1729Cerapur Aeroboiler167selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1730Cerapur Aeroboiler167heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1731Cerapur Aeroboiler167outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1732Cerapur Aeroboiler167curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1733Cerapur Aeroboiler167rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1734Cerapur Aeroboiler167switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1735Cerapur Aeroboiler167syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1736Cerapur Aeroboiler167boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1737Cerapur Aeroboiler167headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1738Cerapur Aeroboiler167exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
1739Cerapur Aeroboiler167burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
1740Cerapur Aeroboiler167burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
1741Cerapur Aeroboiler167flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
1742Cerapur Aeroboiler167fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
1743Cerapur Aeroboiler167ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
1744Cerapur Aeroboiler167oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
1745Cerapur Aeroboiler167burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
1746Cerapur Aeroboiler167burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
1747Cerapur Aeroboiler167burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
1748Cerapur Aeroboiler167absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
1749Cerapur Aeroboiler167heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
1750Cerapur Aeroboiler167boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
1751Cerapur Aeroboiler167boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
1752Cerapur Aeroboiler167boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
1753Cerapur Aeroboiler167boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
1754Cerapur Aeroboiler167curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
1755Cerapur Aeroboiler167curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
1756Cerapur Aeroboiler167curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
1757Cerapur Aeroboiler167summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
1758Cerapur Aeroboiler167nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
1759Cerapur Aeroboiler167nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
1760Cerapur Aeroboiler167heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1761Cerapur Aeroboiler167heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1762Cerapur Aeroboiler167heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1763Cerapur Aeroboiler167pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1764Cerapur Aeroboiler167pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1765Cerapur Aeroboiler167pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1766Cerapur Aeroboiler167pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1767Cerapur Aeroboiler167pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1768Cerapur Aeroboiler167selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
1769Cerapur Aeroboiler167curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
1770Cerapur Aeroboiler167burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
1771Cerapur Aeroboiler167burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
1772Cerapur Aeroboiler167burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
1773Cerapur Aeroboiler167heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
1774Cerapur Aeroboiler167heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
1775Cerapur Aeroboiler167ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
1776Cerapur Aeroboiler167lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
1777Cerapur Aeroboiler167servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
1778Cerapur Aeroboiler167servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
1779Cerapur Aeroboiler167maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
1780Cerapur Aeroboiler167maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
1781Cerapur Aeroboiler167maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
1782Cerapur Aeroboiler167maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
1783Cerapur Aeroboiler167emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
1784Cerapur Aeroboiler167emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
1785Cerapur Aeroboiler167meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
1786Cerapur Aeroboiler167metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1787Cerapur Aeroboiler167gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
1788Cerapur Aeroboiler167gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1789Cerapur Aeroboiler167nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
1790Cerapur Aeroboiler167nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1791Cerapur Aeroboiler167tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1792Cerapur Aeroboiler167settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1793Cerapur Aeroboiler167seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1794Cerapur Aeroboiler167seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1795Cerapur Aeroboiler167tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1796Cerapur Aeroboiler167seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1797Cerapur Aeroboiler167seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1798Cerapur Aeroboiler167solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1799Cerapur Aeroboiler167typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1800Cerapur Aeroboiler167comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1801Cerapur Aeroboiler167comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1802Cerapur Aeroboiler167flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1803Cerapur Aeroboiler167chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1804Cerapur Aeroboiler167maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1805Cerapur Aeroboiler167maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1806Cerapur Aeroboiler167circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1807Cerapur Aeroboiler167chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1808Cerapur Aeroboiler167hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1809Cerapur Aeroboiler167hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1810Cerapur Aeroboiler167disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1811Cerapur Aeroboiler167circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1812Cerapur Aeroboiler167circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1813Cerapur Aeroboiler167curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1814Cerapur Aeroboiler167curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1815Cerapur Aeroboiler167curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1816Cerapur Aeroboiler167storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1817Cerapur Aeroboiler167storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1818Cerapur Aeroboiler167activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1819Cerapur Aeroboiler167onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1820Cerapur Aeroboiler167disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1821Cerapur Aeroboiler167chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1822Cerapur Aeroboiler167rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1823Cerapur Aeroboiler167tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1824Cerapur Aeroboiler167activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1825Cerapur Aeroboiler1673wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1826Cerapur Aeroboiler167mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1827Cerapur Aeroboiler167cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1828Cerapur Aeroboiler167startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1829Cerapur Aeroboiler167workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1830Cerapur Aeroboiler167nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
1831Cerapur Aeroboiler167nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
1832Cerapur Aeroboiler167nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
1833Cerapur Aeroboiler167nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1834Hybrid Heatpumpboiler168resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1835Hybrid Heatpumpboiler168heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1836Hybrid Heatpumpboiler168heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1837Hybrid Heatpumpboiler168tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1838Hybrid Heatpumpboiler168selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1839Hybrid Heatpumpboiler168heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1840Hybrid Heatpumpboiler168outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1841Hybrid Heatpumpboiler168curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1842Hybrid Heatpumpboiler168rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1843Hybrid Heatpumpboiler168switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1844Hybrid Heatpumpboiler168syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1845Hybrid Heatpumpboiler168boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1846Hybrid Heatpumpboiler168headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1847Hybrid Heatpumpboiler168exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
1848Hybrid Heatpumpboiler168burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
1849Hybrid Heatpumpboiler168burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
1850Hybrid Heatpumpboiler168flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
1851Hybrid Heatpumpboiler168fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
1852Hybrid Heatpumpboiler168ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
1853Hybrid Heatpumpboiler168oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
1854Hybrid Heatpumpboiler168burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
1855Hybrid Heatpumpboiler168burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
1856Hybrid Heatpumpboiler168burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
1857Hybrid Heatpumpboiler168absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
1858Hybrid Heatpumpboiler168heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
1859Hybrid Heatpumpboiler168boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
1860Hybrid Heatpumpboiler168boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
1861Hybrid Heatpumpboiler168boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
1862Hybrid Heatpumpboiler168boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
1863Hybrid Heatpumpboiler168curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
1864Hybrid Heatpumpboiler168curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
1865Hybrid Heatpumpboiler168curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
1866Hybrid Heatpumpboiler168summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
1867Hybrid Heatpumpboiler168nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
1868Hybrid Heatpumpboiler168nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
1869Hybrid Heatpumpboiler168heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1870Hybrid Heatpumpboiler168heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1871Hybrid Heatpumpboiler168heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1872Hybrid Heatpumpboiler168pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1873Hybrid Heatpumpboiler168pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1874Hybrid Heatpumpboiler168pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1875Hybrid Heatpumpboiler168pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1876Hybrid Heatpumpboiler168pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1877Hybrid Heatpumpboiler168selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
1878Hybrid Heatpumpboiler168curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
1879Hybrid Heatpumpboiler168burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
1880Hybrid Heatpumpboiler168burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
1881Hybrid Heatpumpboiler168burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
1882Hybrid Heatpumpboiler168heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
1883Hybrid Heatpumpboiler168heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
1884Hybrid Heatpumpboiler168ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
1885Hybrid Heatpumpboiler168lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
1886Hybrid Heatpumpboiler168servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
1887Hybrid Heatpumpboiler168servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
1888Hybrid Heatpumpboiler168maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
1889Hybrid Heatpumpboiler168maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
1890Hybrid Heatpumpboiler168maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
1891Hybrid Heatpumpboiler168maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
1892Hybrid Heatpumpboiler168emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
1893Hybrid Heatpumpboiler168emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
1894Hybrid Heatpumpboiler168meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
1895Hybrid Heatpumpboiler168metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1896Hybrid Heatpumpboiler168gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
1897Hybrid Heatpumpboiler168gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1898Hybrid Heatpumpboiler168nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
1899Hybrid Heatpumpboiler168nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1900Hybrid Heatpumpboiler168tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1901Hybrid Heatpumpboiler168settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1902Hybrid Heatpumpboiler168seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1903Hybrid Heatpumpboiler168seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1904Hybrid Heatpumpboiler168tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1905Hybrid Heatpumpboiler168seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1906Hybrid Heatpumpboiler168seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1907Hybrid Heatpumpboiler168solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1908Hybrid Heatpumpboiler168typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1909Hybrid Heatpumpboiler168comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1910Hybrid Heatpumpboiler168comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1911Hybrid Heatpumpboiler168flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1912Hybrid Heatpumpboiler168chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1913Hybrid Heatpumpboiler168maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1914Hybrid Heatpumpboiler168maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1915Hybrid Heatpumpboiler168circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1916Hybrid Heatpumpboiler168chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1917Hybrid Heatpumpboiler168hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1918Hybrid Heatpumpboiler168hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1919Hybrid Heatpumpboiler168disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1920Hybrid Heatpumpboiler168circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1921Hybrid Heatpumpboiler168circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1922Hybrid Heatpumpboiler168curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1923Hybrid Heatpumpboiler168curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1924Hybrid Heatpumpboiler168curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1925Hybrid Heatpumpboiler168storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1926Hybrid Heatpumpboiler168storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1927Hybrid Heatpumpboiler168activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1928Hybrid Heatpumpboiler168onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1929Hybrid Heatpumpboiler168disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1930Hybrid Heatpumpboiler168chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1931Hybrid Heatpumpboiler168rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1932Hybrid Heatpumpboiler168tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1933Hybrid Heatpumpboiler168activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1934Hybrid Heatpumpboiler1683wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1935Hybrid Heatpumpboiler168mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1936Hybrid Heatpumpboiler168cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1937Hybrid Heatpumpboiler168startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1938Hybrid Heatpumpboiler168workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1939Hybrid Heatpumpboiler168nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
1940Hybrid Heatpumpboiler168nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
1941Hybrid Heatpumpboiler168nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
1942Hybrid Heatpumpboiler168nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1943Logano GB212boiler170resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1944Logano GB212boiler170heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1945Logano GB212boiler170heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1946Logano GB212boiler170tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1947Logano GB212boiler170selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1948Logano GB212boiler170heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1949Logano GB212boiler170outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1950Logano GB212boiler170curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1951Logano GB212boiler170rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1952Logano GB212boiler170switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1953Logano GB212boiler170syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1954Logano GB212boiler170boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1955Logano GB212boiler170headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1956Logano GB212boiler170exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
1957Logano GB212boiler170burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
1958Logano GB212boiler170burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
1959Logano GB212boiler170flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
1960Logano GB212boiler170fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
1961Logano GB212boiler170ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
1962Logano GB212boiler170oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
1963Logano GB212boiler170burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
1964Logano GB212boiler170burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
1965Logano GB212boiler170burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
1966Logano GB212boiler170absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
1967Logano GB212boiler170heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
1968Logano GB212boiler170boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
1969Logano GB212boiler170boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
1970Logano GB212boiler170boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
1971Logano GB212boiler170boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
1972Logano GB212boiler170curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
1973Logano GB212boiler170curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
1974Logano GB212boiler170curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
1975Logano GB212boiler170summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
1976Logano GB212boiler170nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
1977Logano GB212boiler170nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
1978Logano GB212boiler170heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1979Logano GB212boiler170heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1980Logano GB212boiler170heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1981Logano GB212boiler170pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1982Logano GB212boiler170pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1983Logano GB212boiler170pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1984Logano GB212boiler170pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1985Logano GB212boiler170pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1986Logano GB212boiler170selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
1987Logano GB212boiler170curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
1988Logano GB212boiler170burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
1989Logano GB212boiler170burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
1990Logano GB212boiler170burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
1991Logano GB212boiler170heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
1992Logano GB212boiler170heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
1993Logano GB212boiler170ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
1994Logano GB212boiler170lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
1995Logano GB212boiler170servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
1996Logano GB212boiler170servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
1997Logano GB212boiler170maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
1998Logano GB212boiler170maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
1999Logano GB212boiler170maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
2000Logano GB212boiler170maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
2001Logano GB212boiler170emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
2002Logano GB212boiler170emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
2003Logano GB212boiler170meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10902
2004Logano GB212boiler170metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
2005Logano GB212boiler170gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102542
2006Logano GB212boiler170gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
2007Logano GB212boiler170nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102562
2008Logano GB212boiler170nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
2009Logano GB212boiler170tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
2010Logano GB212boiler170settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
2011Logano GB212boiler170seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
2012Logano GB212boiler170seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
2013Logano GB212boiler170tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
2014Logano GB212boiler170seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
2015Logano GB212boiler170seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
2016Logano GB212boiler170solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
2017Logano GB212boiler170typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
2018Logano GB212boiler170comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
2019Logano GB212boiler170comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
2020Logano GB212boiler170flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
2021Logano GB212boiler170chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
2022Logano GB212boiler170maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
2023Logano GB212boiler170maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
2024Logano GB212boiler170circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
2025Logano GB212boiler170chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
2026Logano GB212boiler170hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
2027Logano GB212boiler170hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
2028Logano GB212boiler170disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
2029Logano GB212boiler170circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
2030Logano GB212boiler170circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
2031Logano GB212boiler170curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
2032Logano GB212boiler170curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
2033Logano GB212boiler170curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
2034Logano GB212boiler170storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
2035Logano GB212boiler170storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
2036Logano GB212boiler170activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
2037Logano GB212boiler170onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
2038Logano GB212boiler170disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
2039Logano GB212boiler170chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
2040Logano GB212boiler170rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
2041Logano GB212boiler170tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
2042Logano GB212boiler170activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
2043Logano GB212boiler1703wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
2044Logano GB212boiler170mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
2045Logano GB212boiler170cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
2046Logano GB212boiler170startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
2047Logano GB212boiler170workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
2048Logano GB212boiler170nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012581
2049Logano GB212boiler170nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
2050Logano GB212boiler170nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100822
2051Logano GB212boiler170nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
2052Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
2053Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
2054Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
2055Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
2056Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
2057Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
2058Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
2059Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
2060Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
2061Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
2062Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
2063Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
2064Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
2065Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
2066Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
2067Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
2068Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
2069Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
2070Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
2071Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
2072Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
2073Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
2074Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
2075Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
2076Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
2077Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
2078Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
2079Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
2080Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
2081Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
2082Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
2083Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
2084Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
2085Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
2086Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
2087Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
2088Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
2089Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
2090Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
2091Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgenergyuint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_energysensor.boiler_dhw_nrg591/10002
2092Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgheatenergy heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_heatingsensor.boiler_nrgheat501/100822
2093Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgcoolenergy coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_coolingsensor.boiler_nrgcool501/1002642
2094Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172metertotalmeter totaluint24 (>=0<=167772)kWhfalsesensor.boiler_meter_totalsensor.boiler_metertotal501/100842
2095Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172metercompmeter compressoruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_compressorsensor.boiler_metercomp501/100862
2096Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172metereheatmeter e-heateruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_e-heatersensor.boiler_metereheat501/100882
2097Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172meterheatmeter heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/100902
2098Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172metercoolmeter coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_coolingsensor.boiler_metercool501/1002662
2099Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172metermeteruint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/10022
2100Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172uptimetotalheatpump total uptimetime (>=0<=279620)minutesfalsesensor.boiler_heatpump_total_uptimesensor.boiler_uptimetotal501/60922
2101Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172uptimecontroltotal operating time heattime (>=0<=279620)minutesfalsesensor.boiler_total_operating_time_heatsensor.boiler_uptimecontrol501/60942
2102Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172uptimecompheatingoperating time compressor heatingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_heatingsensor.boiler_uptimecompheating501/60962
2103Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172uptimecompcoolingoperating time compressor coolingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_coolingsensor.boiler_uptimecompcooling501/60982
2104Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172uptimecompoperating time compressortime (>=0<=279620)minutesfalsesensor.boiler_dhw_operating_time_compressorsensor.boiler_dhw_uptimecomp591/6042
2105Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172uptimecomppooloperating time compressor pooltime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_poolsensor.boiler_uptimecomppool501/601002
2106Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172totalcompstartstotal compressor control startsuint24 (>=0<=16777213)falsesensor.boiler_total_compressor_control_startssensor.boiler_totalcompstarts5011022
2107Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatingstartsheating control startsuint24 (>=0<=16777213)falsesensor.boiler_heating_control_startssensor.boiler_heatingstarts5011042
2108Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172coolingstartscooling control startsuint24 (>=0<=16777213)falsesensor.boiler_cooling_control_startssensor.boiler_coolingstarts5011062
2109Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172starts2control starts2uint24 (>=0<=16777213)falsesensor.boiler_dhw_control_starts2sensor.boiler_dhw_starts259162
2110Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172poolstartspool control startsuint24 (>=0<=16777213)falsesensor.boiler_pool_control_startssensor.boiler_poolstarts5011082
2111Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgconstotaltotal energy consumptionuint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_consumptionsensor.boiler_nrgconstotal5011102
2112Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgconscomptotaltotal energy consumption compressoruint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_consumption_compressorsensor.boiler_nrgconscomptotal5011122
2113Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgconscompheatingenergy consumption compressor heatinguint24 (>=0<=16777213)kWhfalsesensor.boiler_energy_consumption_compressor_heatingsensor.boiler_nrgconscompheating5011142
2114Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgconscompenergy consumption compressoruint24 (>=0<=16777213)kWhfalsesensor.boiler_dhw_energy_consumption_compressorsensor.boiler_dhw_nrgconscomp59182
2115Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgconscompcoolingenergy consumption compressor coolinguint24 (>=0<=16777213)kWhfalsesensor.boiler_energy_consumption_compressor_coolingsensor.boiler_nrgconscompcooling5011162
2116Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgconscomppoolenergy consumption compressor pooluint24 (>=0<=16777213)kWhfalsesensor.boiler_energy_consumption_compressor_poolsensor.boiler_nrgconscomppool5011182
2117Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxelecheatnrgconstotaltotal aux elec. heater energy consumptionuint24 (>=0<=16777213)kWhfalsesensor.boiler_total_aux_elec._heater_energy_consumptionsensor.boiler_auxelecheatnrgconstotal5011202
2118Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxelecheatnrgconsheatingaux elec. heater energy consumption heatinguint24 (>=0<=16777213)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_heatingsensor.boiler_auxelecheatnrgconsheating5011222
2119Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxelecheatnrgconsaux elec. heater energy consumptionuint24 (>=0<=16777213)kWhfalsesensor.boiler_dhw_aux_elec._heater_energy_consumptionsensor.boiler_dhw_auxelecheatnrgcons591102
2120Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxelecheatnrgconspoolaux elec. heater energy consumption pooluint24 (>=0<=16777213)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_poolsensor.boiler_auxelecheatnrgconspool5011242
2121Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgsupptotaltotal energy supplieduint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_suppliedsensor.boiler_nrgsupptotal5011262
2122Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgsuppheatingtotal energy supplied heatinguint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_supplied_heatingsensor.boiler_nrgsuppheating5011282
2123Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgsupptotal energy warm supplieduint24 (>=0<=16777213)kWhfalsesensor.boiler_dhw_total_energy_warm_suppliedsensor.boiler_dhw_nrgsupp591122
2124Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgsuppcoolingtotal energy supplied coolinguint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_supplied_coolingsensor.boiler_nrgsuppcooling5011302
2125Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172nrgsupppooltotal energy supplied pooluint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_supplied_poolsensor.boiler_nrgsupppool5011322
2126Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hppowercompressor power outputuint8 (>=0<=25)kWfalsesensor.boiler_compressor_power_outputsensor.boiler_hppower501/101341
2127Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpmaxpowercompressor max poweruint8 (>=0<=100)%truenumber.boiler_compressor_max_powernumber.boiler_hpmaxpower5011351
2128Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpsetdiffpressset differental pressureuint8 (>=150<=750)mbartruenumber.boiler_set_differental_pressurenumber.boiler_hpsetdiffpress50501361
2129Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpcomponhp compressorbooleanfalsebinary_sensor.boiler_hp_compressorbinary_sensor.boiler_hpcompon5011371
2130Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpactivitycompressor activityenum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost]falsesensor.boiler_compressor_activitysensor.boiler_hpactivity5011381
2131Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpbrinepumpspdbrine pump speeduint8 (>=0<=100)%falsesensor.boiler_brine_pump_speedsensor.boiler_hpbrinepumpspd5011391
2132Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpswitchvalveswitch valvebooleanfalsebinary_sensor.boiler_switch_valvebinary_sensor.boiler_hpswitchvalve5011401
2133Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpcompspdcompressor speeduint8 (>=0<=100)%falsesensor.boiler_compressor_speedsensor.boiler_hpcompspd5011411
2134Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpcircspdcirculation pump speeduint8 (>=0<=100)%falsesensor.boiler_circulation_pump_speedsensor.boiler_hpcircspd5011421
2135Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpbrineinbrine in/evaporatorint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_in/evaporatorsensor.boiler_hpbrinein501/101431
2136Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpbrineoutbrine out/condenserint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_out/condensersensor.boiler_hpbrineout501/101441
2137Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptc0heat carrier return (TC0)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_return_(TC0)sensor.boiler_hptc0501/101451
2138Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptc1heat carrier forward (TC1)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_forward_(TC1)sensor.boiler_hptc1501/101461
2139Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptc3condenser temperature (TC3)int16 (>=-3199<=3199)Cfalsesensor.boiler_condenser_temperature_(TC3)sensor.boiler_hptc3501/101471
2140Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptr1compressor temperature (TR1)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_temperature_(TR1)sensor.boiler_hptr1501/101481
2141Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptr3refrigerant temperature liquid side (condenser output) (TR3)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3)sensor.boiler_hptr3501/101491
2142Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptr4evaporator inlet temperature (TR4)int16 (>=-3199<=3199)Cfalsesensor.boiler_evaporator_inlet_temperature_(TR4)sensor.boiler_hptr4501/101501
2143Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptr5compressor inlet temperature (TR5)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_inlet_temperature_(TR5)sensor.boiler_hptr5501/101511
2144Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptr6compressor outlet temperature (TR6)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_outlet_temperature_(TR6)sensor.boiler_hptr6501/101521
2145Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptr7refrigerant temperature gas side (condenser input) (TR7)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7)sensor.boiler_hptr7501/101531
2146Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptl2air inlet temperature (TL2)int16 (>=-3199<=3199)Cfalsesensor.boiler_air_inlet_temperature_(TL2)sensor.boiler_hptl2501/101541
2147Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hppl1low pressure side temperature (PL1)int16 (>=-3199<=3199)Cfalsesensor.boiler_low_pressure_side_temperature_(PL1)sensor.boiler_hppl1501/101551
2148Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpph1high pressure side temperature (PH1)int16 (>=-3199<=3199)Cfalsesensor.boiler_high_pressure_side_temperature_(PH1)sensor.boiler_hpph1501/101561
2149Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpta4drain pan temp (TA4)int16 (>=-3199<=3199)Cfalsesensor.boiler_drain_pan_temp_(TA4)sensor.boiler_hpta4501/101571
2150Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hptw1reservoir temp (TW1)int16 (>=-3199<=3199)Cfalsesensor.boiler_reservoir_temp_(TW1)sensor.boiler_hptw1501/101581
2151Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172poolsettemppool set temperatureuint8 (>=0<=127)Ctruenumber.boiler_pool_set_temperaturenumber.boiler_poolsettemp501/21591
2152Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hp4way4-way valve (VR4)enum [cooling & defrost\|heating & dhw]falsesensor.boiler_4-way_valve_(VR4)sensor.boiler_hp4way5011601
2153Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpin1input 1 statebooleanfalsebinary_sensor.boiler_input_1_statebinary_sensor.boiler_hpin15011611
2154Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpin1optinput 1 optionsstringtruesensor.boiler_input_1_optionssensor.boiler_hpin1opt5011628
2155Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpin2input 2 statebooleanfalsebinary_sensor.boiler_input_2_statebinary_sensor.boiler_hpin25011701
2156Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpin2optinput 2 optionsstringtruesensor.boiler_input_2_optionssensor.boiler_hpin2opt5011718
2157Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpin3input 3 statebooleanfalsebinary_sensor.boiler_input_3_statebinary_sensor.boiler_hpin35011791
2158Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpin3optinput 3 optionsstringtruesensor.boiler_input_3_optionssensor.boiler_hpin3opt5011808
2159Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpin4input 4 statebooleanfalsebinary_sensor.boiler_input_4_statebinary_sensor.boiler_hpin45011881
2160Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpin4optinput 4 optionsstringtruesensor.boiler_input_4_optionssensor.boiler_hpin4opt5011898
2161Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maxheatcompheat limit compressorenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_compressorselect.boiler_maxheatcomp5011971
2162Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maxheatheatheat limit heatingenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_heatingselect.boiler_maxheatheat5011981
2163Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maxheatheat limitenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_dhw_heat_limitselect.boiler_dhw_maxheat591141
2164Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172mandefrostmanual defrostbooleantrueswitch.boiler_manual_defrostswitch.boiler_mandefrost5011991
2165Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172pvcoolingcooling only with PVbooleantrueswitch.boiler_cooling_only_with_PVswitch.boiler_pvcooling5012001
2166Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxheateronlyaux heater onlybooleantrueswitch.boiler_aux_heater_onlyswitch.boiler_auxheateronly5012011
2167Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxheateroffdisable aux heaterbooleantrueswitch.boiler_disable_aux_heaterswitch.boiler_auxheateroff5012021
2168Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxheaterstatusaux heater statusuint8 (>=0<=100)%falsesensor.boiler_aux_heater_statussensor.boiler_auxheaterstatus5012031
2169Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxheaterdelayaux heater on delayuint16 (>=10<=1000)K*mintruenumber.boiler_aux_heater_on_delaynumber.boiler_auxheaterdelay50102041
2170Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxmaxlimitaux heater max limituint8 (>=0<=10)Ktruenumber.boiler_aux_heater_max_limitnumber.boiler_auxmaxlimit501/102051
2171Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxlimitstartaux heater limit startuint8 (>=0<=10)Ktruenumber.boiler_aux_heater_limit_startnumber.boiler_auxlimitstart501/102061
2172Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxheatrmodeaux heater modeenum [eco\|comfort]trueselect.boiler_aux_heater_modeselect.boiler_auxheatrmode5012071
2173Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hphystheaton/off hyst heatuint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_heatnumber.boiler_hphystheat5052081
2174Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hphystcoolon/off hyst cooluint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_coolnumber.boiler_hphystcool5052091
2175Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hphystpoolon/off hyst pooluint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_poolnumber.boiler_hphystpool5052101
2176Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172silentmodesilent modeenum [off\|auto\|on]trueselect.boiler_silent_modeselect.boiler_silentmode5012111
2177Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172silentfromsilent mode fromuint8 (>=0<=3810)minutestruenumber.boiler_silent_mode_fromnumber.boiler_silentfrom50152121
2178Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172silenttosilent mode touint8 (>=0<=3810)minutestruenumber.boiler_silent_mode_tonumber.boiler_silentto50152131
2179Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172mintempsilentmin outside temp for silent modeint8 (>=-126<=126)Ctruenumber.boiler_min_outside_temp_for_silent_modenumber.boiler_mintempsilent5012141
2180Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172tempparmodeoutside temp parallel modeint8 (>=-126<=126)Ctruenumber.boiler_outside_temp_parallel_modenumber.boiler_tempparmode5012151
2181Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172auxheatmixaux heater mixing valveint8 (>=-100<=100)%falsesensor.boiler_aux_heater_mixing_valvesensor.boiler_auxheatmix5012161
2182Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172tempdiffheattemp diff TC3/TC0 heatuint8 (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_heatnumber.boiler_tempdiffheat501/102171
2183Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172tempdiffcooltemp diff TC3/TC0 cooluint8 (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_coolnumber.boiler_tempdiffcool501/102181
2184Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172vpcoolingvalve/pump coolingbooleantrueswitch.boiler_valve/pump_coolingswitch.boiler_vpcooling5012191
2185Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172heatcableheating cablebooleantrueswitch.boiler_heating_cableswitch.boiler_heatcable5012201
2186Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172vc0valveVC0 valvebooleantrueswitch.boiler_VC0_valveswitch.boiler_vc0valve5012211
2187Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172primepumpprimary heatpumpbooleantrueswitch.boiler_primary_heatpumpswitch.boiler_primepump5012221
2188Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172primepumpmodprimary heatpump modulationuint8 (>=0<=100)%truenumber.boiler_primary_heatpump_modulationnumber.boiler_primepumpmod5012231
2189Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hp3way3-way valvebooleantrueswitch.boiler_3-way_valveswitch.boiler_hp3way5012241
2190Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172elheatstep1el. heater step 1booleantrueswitch.boiler_el._heater_step_1switch.boiler_elheatstep15012251
2191Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172elheatstep2el. heater step 2booleantrueswitch.boiler_el._heater_step_2switch.boiler_elheatstep25012261
2192Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172elheatstep3el. heater step 3booleantrueswitch.boiler_el._heater_step_3switch.boiler_elheatstep35012271
2193Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpea0condensate reservoir heating (EA0)booleanfalsebinary_sensor.boiler_condensate_reservoir_heating_(EA0)binary_sensor.boiler_hpea05012281
2194Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hppumpmodeprimary heatpump modeenum [auto\|continuous]trueselect.boiler_primary_heatpump_modeselect.boiler_hppumpmode5012291
2195Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172fanfanuint8 (>=20<=100)%truenumber.boiler_fannumber.boiler_fan5012301
2196Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172shutdownshutdowncmd [off\|on]truesensor.boiler_shutdownsensor.boiler_shutdown5012311
2197Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172alternatingopalternating operationbooleantrueswitch.boiler_dhw_alternating_operationswitch.boiler_dhw_alternatingop591151
2198Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172altopprioheatprioritise heating during dhwuint8 (>=20<=120)minutestruenumber.boiler_dhw_prioritise_heating_during_dhwnumber.boiler_dhw_altopprioheat591161
2199Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172altopprioprioritise dhw during heatinguint8 (>=30<=120)minutestruenumber.boiler_dhw_prioritise_dhw_during_heatingnumber.boiler_dhw_altopprio591171
2200Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172comfoffcomfort switch offuint8 (>=15<=65)Ctruenumber.boiler_dhw_comfort_switch_offnumber.boiler_dhw_comfoff591181
2201Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172ecooffeco switch offuint8 (>=15<=65)Ctruenumber.boiler_dhw_eco_switch_offnumber.boiler_dhw_ecooff591191
2202Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172ecoplusoffeco+ switch offuint8 (>=48<=63)Ctruenumber.boiler_dhw_eco+_switch_offnumber.boiler_dhw_ecoplusoff591201
2203Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172comfdiffcomfort diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_comfort_diffnumber.boiler_dhw_comfdiff591211
2204Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172ecodiffeco diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_eco_diffnumber.boiler_dhw_ecodiff591221
2205Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172ecoplusdiffeco+ diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_eco+_diffnumber.boiler_dhw_ecoplusdiff591231
2206Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172comfstopcomfort stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_comfort_stop_tempnumber.boiler_dhw_comfstop591241
2207Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172ecostopeco stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_eco_stop_tempnumber.boiler_dhw_ecostop591251
2208Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172ecoplusstopeco+ stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_eco+_stop_tempnumber.boiler_dhw_ecoplusstop591261
2209Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hpcircpumpcirculation pump available during dhwbooleantrueswitch.boiler_dhw_circulation_pump_available_during_dhwswitch.boiler_dhw_hpcircpump591271
2210Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
2211Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
2212Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
2213Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
2214Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
2215Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
2216Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
2217Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
2218Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
2219Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
2220Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
2221Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
2222Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
2223Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
2224Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
2225Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
2226Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
2227Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
2228Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
2229Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
2230Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
2231Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
2232Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
2233Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
2234Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
2235Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
2236Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
2237Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
2238Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
2239Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
2240Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
2241Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
2242Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
2243Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
2244Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler1723wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
2245Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
2246Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
2247Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
2248Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196iboiler172workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
2249Geo 5xxboiler173resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
2250Geo 5xxboiler173heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
2251Geo 5xxboiler173heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
2252Geo 5xxboiler173tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
2253Geo 5xxboiler173selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
2254Geo 5xxboiler173heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
2255Geo 5xxboiler173outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
2256Geo 5xxboiler173curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
2257Geo 5xxboiler173rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
2258Geo 5xxboiler173switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
2259Geo 5xxboiler173syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
2260Geo 5xxboiler173boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
2261Geo 5xxboiler173headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
2262Geo 5xxboiler173heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
2263Geo 5xxboiler173heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
2264Geo 5xxboiler173heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
2265Geo 5xxboiler173pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
2266Geo 5xxboiler173pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
2267Geo 5xxboiler173pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
2268Geo 5xxboiler173pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
2269Geo 5xxboiler173pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
2270Geo 5xxboiler173selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
2271Geo 5xxboiler173curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
2272Geo 5xxboiler173burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
2273Geo 5xxboiler173burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
2274Geo 5xxboiler173burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
2275Geo 5xxboiler173heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
2276Geo 5xxboiler173heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
2277Geo 5xxboiler173ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
2278Geo 5xxboiler173lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
2279Geo 5xxboiler173servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
2280Geo 5xxboiler173servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
2281Geo 5xxboiler173maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682
2282Geo 5xxboiler173maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501701
2283Geo 5xxboiler173maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501711
2284Geo 5xxboiler173maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501726
2285Geo 5xxboiler173emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501781
2286Geo 5xxboiler173emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501791
2287Geo 5xxboiler173nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100802
2288Geo 5xxboiler173nrgenergyuint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_energysensor.boiler_dhw_nrg591/10002
2289Geo 5xxboiler173nrgheatenergy heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_heatingsensor.boiler_nrgheat501/100822
2290Geo 5xxboiler173nrgcoolenergy coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_coolingsensor.boiler_nrgcool501/1002642
2291Geo 5xxboiler173metertotalmeter totaluint24 (>=0<=167772)kWhfalsesensor.boiler_meter_totalsensor.boiler_metertotal501/100842
2292Geo 5xxboiler173metercompmeter compressoruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_compressorsensor.boiler_metercomp501/100862
2293Geo 5xxboiler173metereheatmeter e-heateruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_e-heatersensor.boiler_metereheat501/100882
2294Geo 5xxboiler173meterheatmeter heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/100902
2295Geo 5xxboiler173metercoolmeter coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_coolingsensor.boiler_metercool501/1002662
2296Geo 5xxboiler173metermeteruint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/10022
2297Geo 5xxboiler173uptimetotalheatpump total uptimetime (>=0<=279620)minutesfalsesensor.boiler_heatpump_total_uptimesensor.boiler_uptimetotal501/60922
2298Geo 5xxboiler173uptimecontroltotal operating time heattime (>=0<=279620)minutesfalsesensor.boiler_total_operating_time_heatsensor.boiler_uptimecontrol501/60942
2299Geo 5xxboiler173uptimecompheatingoperating time compressor heatingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_heatingsensor.boiler_uptimecompheating501/60962
2300Geo 5xxboiler173uptimecompcoolingoperating time compressor coolingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_coolingsensor.boiler_uptimecompcooling501/60982
2301Geo 5xxboiler173uptimecompoperating time compressortime (>=0<=279620)minutesfalsesensor.boiler_dhw_operating_time_compressorsensor.boiler_dhw_uptimecomp591/6042
2302Geo 5xxboiler173uptimecomppooloperating time compressor pooltime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_poolsensor.boiler_uptimecomppool501/601002
2303Geo 5xxboiler173totalcompstartstotal compressor control startsuint24 (>=0<=16777213)falsesensor.boiler_total_compressor_control_startssensor.boiler_totalcompstarts5011022
2304Geo 5xxboiler173heatingstartsheating control startsuint24 (>=0<=16777213)falsesensor.boiler_heating_control_startssensor.boiler_heatingstarts5011042
2305Geo 5xxboiler173coolingstartscooling control startsuint24 (>=0<=16777213)falsesensor.boiler_cooling_control_startssensor.boiler_coolingstarts5011062
2306Geo 5xxboiler173starts2control starts2uint24 (>=0<=16777213)falsesensor.boiler_dhw_control_starts2sensor.boiler_dhw_starts259162
2307Geo 5xxboiler173poolstartspool control startsuint24 (>=0<=16777213)falsesensor.boiler_pool_control_startssensor.boiler_poolstarts5011082
2308Geo 5xxboiler173nrgconstotaltotal energy consumptionuint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_consumptionsensor.boiler_nrgconstotal5011102
2309Geo 5xxboiler173nrgconscomptotaltotal energy consumption compressoruint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_consumption_compressorsensor.boiler_nrgconscomptotal5011122
2310Geo 5xxboiler173nrgconscompheatingenergy consumption compressor heatinguint24 (>=0<=16777213)kWhfalsesensor.boiler_energy_consumption_compressor_heatingsensor.boiler_nrgconscompheating5011142
2311Geo 5xxboiler173nrgconscompenergy consumption compressoruint24 (>=0<=16777213)kWhfalsesensor.boiler_dhw_energy_consumption_compressorsensor.boiler_dhw_nrgconscomp59182
2312Geo 5xxboiler173nrgconscompcoolingenergy consumption compressor coolinguint24 (>=0<=16777213)kWhfalsesensor.boiler_energy_consumption_compressor_coolingsensor.boiler_nrgconscompcooling5011162
2313Geo 5xxboiler173nrgconscomppoolenergy consumption compressor pooluint24 (>=0<=16777213)kWhfalsesensor.boiler_energy_consumption_compressor_poolsensor.boiler_nrgconscomppool5011182
2314Geo 5xxboiler173auxelecheatnrgconstotaltotal aux elec. heater energy consumptionuint24 (>=0<=16777213)kWhfalsesensor.boiler_total_aux_elec._heater_energy_consumptionsensor.boiler_auxelecheatnrgconstotal5011202
2315Geo 5xxboiler173auxelecheatnrgconsheatingaux elec. heater energy consumption heatinguint24 (>=0<=16777213)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_heatingsensor.boiler_auxelecheatnrgconsheating5011222
2316Geo 5xxboiler173auxelecheatnrgconsaux elec. heater energy consumptionuint24 (>=0<=16777213)kWhfalsesensor.boiler_dhw_aux_elec._heater_energy_consumptionsensor.boiler_dhw_auxelecheatnrgcons591102
2317Geo 5xxboiler173auxelecheatnrgconspoolaux elec. heater energy consumption pooluint24 (>=0<=16777213)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_poolsensor.boiler_auxelecheatnrgconspool5011242
2318Geo 5xxboiler173nrgsupptotaltotal energy supplieduint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_suppliedsensor.boiler_nrgsupptotal5011262
2319Geo 5xxboiler173nrgsuppheatingtotal energy supplied heatinguint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_supplied_heatingsensor.boiler_nrgsuppheating5011282
2320Geo 5xxboiler173nrgsupptotal energy warm supplieduint24 (>=0<=16777213)kWhfalsesensor.boiler_dhw_total_energy_warm_suppliedsensor.boiler_dhw_nrgsupp591122
2321Geo 5xxboiler173nrgsuppcoolingtotal energy supplied coolinguint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_supplied_coolingsensor.boiler_nrgsuppcooling5011302
2322Geo 5xxboiler173nrgsupppooltotal energy supplied pooluint24 (>=0<=16777213)kWhfalsesensor.boiler_total_energy_supplied_poolsensor.boiler_nrgsupppool5011322
2323Geo 5xxboiler173hppowercompressor power outputuint8 (>=0<=25)kWfalsesensor.boiler_compressor_power_outputsensor.boiler_hppower501/101341
2324Geo 5xxboiler173hpmaxpowercompressor max poweruint8 (>=0<=100)%truenumber.boiler_compressor_max_powernumber.boiler_hpmaxpower5011351
2325Geo 5xxboiler173hpsetdiffpressset differental pressureuint8 (>=150<=750)mbartruenumber.boiler_set_differental_pressurenumber.boiler_hpsetdiffpress50501361
2326Geo 5xxboiler173hpcomponhp compressorbooleanfalsebinary_sensor.boiler_hp_compressorbinary_sensor.boiler_hpcompon5011371
2327Geo 5xxboiler173hpactivitycompressor activityenum [none\|heating\|cooling\|hot water\|pool\|unknown\|defrost]falsesensor.boiler_compressor_activitysensor.boiler_hpactivity5011381
2328Geo 5xxboiler173hpbrinepumpspdbrine pump speeduint8 (>=0<=100)%falsesensor.boiler_brine_pump_speedsensor.boiler_hpbrinepumpspd5011391
2329Geo 5xxboiler173hpswitchvalveswitch valvebooleanfalsebinary_sensor.boiler_switch_valvebinary_sensor.boiler_hpswitchvalve5011401
2330Geo 5xxboiler173hpcompspdcompressor speeduint8 (>=0<=100)%falsesensor.boiler_compressor_speedsensor.boiler_hpcompspd5011411
2331Geo 5xxboiler173hpcircspdcirculation pump speeduint8 (>=0<=100)%falsesensor.boiler_circulation_pump_speedsensor.boiler_hpcircspd5011421
2332Geo 5xxboiler173hpbrineinbrine in/evaporatorint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_in/evaporatorsensor.boiler_hpbrinein501/101431
2333Geo 5xxboiler173hpbrineoutbrine out/condenserint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_out/condensersensor.boiler_hpbrineout501/101441
2334Geo 5xxboiler173hptc0heat carrier return (TC0)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_return_(TC0)sensor.boiler_hptc0501/101451
2335Geo 5xxboiler173hptc1heat carrier forward (TC1)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_forward_(TC1)sensor.boiler_hptc1501/101461
2336Geo 5xxboiler173hptc3condenser temperature (TC3)int16 (>=-3199<=3199)Cfalsesensor.boiler_condenser_temperature_(TC3)sensor.boiler_hptc3501/101471
2337Geo 5xxboiler173hptr1compressor temperature (TR1)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_temperature_(TR1)sensor.boiler_hptr1501/101481
2338Geo 5xxboiler173hptr3refrigerant temperature liquid side (condenser output) (TR3)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3)sensor.boiler_hptr3501/101491
2339Geo 5xxboiler173hptr4evaporator inlet temperature (TR4)int16 (>=-3199<=3199)Cfalsesensor.boiler_evaporator_inlet_temperature_(TR4)sensor.boiler_hptr4501/101501
2340Geo 5xxboiler173hptr5compressor inlet temperature (TR5)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_inlet_temperature_(TR5)sensor.boiler_hptr5501/101511
2341Geo 5xxboiler173hptr6compressor outlet temperature (TR6)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_outlet_temperature_(TR6)sensor.boiler_hptr6501/101521
2342Geo 5xxboiler173hptr7refrigerant temperature gas side (condenser input) (TR7)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7)sensor.boiler_hptr7501/101531
2343Geo 5xxboiler173hptl2air inlet temperature (TL2)int16 (>=-3199<=3199)Cfalsesensor.boiler_air_inlet_temperature_(TL2)sensor.boiler_hptl2501/101541
2344Geo 5xxboiler173hppl1low pressure side temperature (PL1)int16 (>=-3199<=3199)Cfalsesensor.boiler_low_pressure_side_temperature_(PL1)sensor.boiler_hppl1501/101551
2345Geo 5xxboiler173hpph1high pressure side temperature (PH1)int16 (>=-3199<=3199)Cfalsesensor.boiler_high_pressure_side_temperature_(PH1)sensor.boiler_hpph1501/101561
2346Geo 5xxboiler173hpta4drain pan temp (TA4)int16 (>=-3199<=3199)Cfalsesensor.boiler_drain_pan_temp_(TA4)sensor.boiler_hpta4501/101571
2347Geo 5xxboiler173hptw1reservoir temp (TW1)int16 (>=-3199<=3199)Cfalsesensor.boiler_reservoir_temp_(TW1)sensor.boiler_hptw1501/101581
2348Geo 5xxboiler173poolsettemppool set temperatureuint8 (>=0<=127)Ctruenumber.boiler_pool_set_temperaturenumber.boiler_poolsettemp501/21591
2349Geo 5xxboiler173hp4way4-way valve (VR4)enum [cooling & defrost\|heating & dhw]falsesensor.boiler_4-way_valve_(VR4)sensor.boiler_hp4way5011601
2350Geo 5xxboiler173hpin1input 1 statebooleanfalsebinary_sensor.boiler_input_1_statebinary_sensor.boiler_hpin15011611
2351Geo 5xxboiler173hpin1optinput 1 optionsstringtruesensor.boiler_input_1_optionssensor.boiler_hpin1opt5011628
2352Geo 5xxboiler173hpin2input 2 statebooleanfalsebinary_sensor.boiler_input_2_statebinary_sensor.boiler_hpin25011701
2353Geo 5xxboiler173hpin2optinput 2 optionsstringtruesensor.boiler_input_2_optionssensor.boiler_hpin2opt5011718
2354Geo 5xxboiler173hpin3input 3 statebooleanfalsebinary_sensor.boiler_input_3_statebinary_sensor.boiler_hpin35011791
2355Geo 5xxboiler173hpin3optinput 3 optionsstringtruesensor.boiler_input_3_optionssensor.boiler_hpin3opt5011808
2356Geo 5xxboiler173hpin4input 4 statebooleanfalsebinary_sensor.boiler_input_4_statebinary_sensor.boiler_hpin45011881
2357Geo 5xxboiler173hpin4optinput 4 optionsstringtruesensor.boiler_input_4_optionssensor.boiler_hpin4opt5011898
2358Geo 5xxboiler173maxheatcompheat limit compressorenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_compressorselect.boiler_maxheatcomp5011971
2359Geo 5xxboiler173maxheatheatheat limit heatingenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_heatingselect.boiler_maxheatheat5011981
2360Geo 5xxboiler173maxheatheat limitenum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW]trueselect.boiler_dhw_heat_limitselect.boiler_dhw_maxheat591141
2361Geo 5xxboiler173mandefrostmanual defrostbooleantrueswitch.boiler_manual_defrostswitch.boiler_mandefrost5011991
2362Geo 5xxboiler173pvcoolingcooling only with PVbooleantrueswitch.boiler_cooling_only_with_PVswitch.boiler_pvcooling5012001
2363Geo 5xxboiler173auxheateronlyaux heater onlybooleantrueswitch.boiler_aux_heater_onlyswitch.boiler_auxheateronly5012011
2364Geo 5xxboiler173auxheateroffdisable aux heaterbooleantrueswitch.boiler_disable_aux_heaterswitch.boiler_auxheateroff5012021
2365Geo 5xxboiler173auxheaterstatusaux heater statusuint8 (>=0<=100)%falsesensor.boiler_aux_heater_statussensor.boiler_auxheaterstatus5012031
2366Geo 5xxboiler173auxheaterdelayaux heater on delayuint16 (>=10<=1000)K*mintruenumber.boiler_aux_heater_on_delaynumber.boiler_auxheaterdelay50102041
2367Geo 5xxboiler173auxmaxlimitaux heater max limituint8 (>=0<=10)Ktruenumber.boiler_aux_heater_max_limitnumber.boiler_auxmaxlimit501/102051
2368Geo 5xxboiler173auxlimitstartaux heater limit startuint8 (>=0<=10)Ktruenumber.boiler_aux_heater_limit_startnumber.boiler_auxlimitstart501/102061
2369Geo 5xxboiler173auxheatrmodeaux heater modeenum [eco\|comfort]trueselect.boiler_aux_heater_modeselect.boiler_auxheatrmode5012071
2370Geo 5xxboiler173hphystheaton/off hyst heatuint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_heatnumber.boiler_hphystheat5052081
2371Geo 5xxboiler173hphystcoolon/off hyst cooluint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_coolnumber.boiler_hphystcool5052091
2372Geo 5xxboiler173hphystpoolon/off hyst pooluint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_poolnumber.boiler_hphystpool5052101
2373Geo 5xxboiler173silentmodesilent modeenum [off\|auto\|on]trueselect.boiler_silent_modeselect.boiler_silentmode5012111
2374Geo 5xxboiler173silentfromsilent mode fromuint8 (>=0<=3810)minutestruenumber.boiler_silent_mode_fromnumber.boiler_silentfrom50152121
2375Geo 5xxboiler173silenttosilent mode touint8 (>=0<=3810)minutestruenumber.boiler_silent_mode_tonumber.boiler_silentto50152131
2376Geo 5xxboiler173mintempsilentmin outside temp for silent modeint8 (>=-126<=126)Ctruenumber.boiler_min_outside_temp_for_silent_modenumber.boiler_mintempsilent5012141
2377Geo 5xxboiler173tempparmodeoutside temp parallel modeint8 (>=-126<=126)Ctruenumber.boiler_outside_temp_parallel_modenumber.boiler_tempparmode5012151
2378Geo 5xxboiler173auxheatmixaux heater mixing valveint8 (>=-100<=100)%falsesensor.boiler_aux_heater_mixing_valvesensor.boiler_auxheatmix5012161
2379Geo 5xxboiler173tempdiffheattemp diff TC3/TC0 heatuint8 (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_heatnumber.boiler_tempdiffheat501/102171
2380Geo 5xxboiler173tempdiffcooltemp diff TC3/TC0 cooluint8 (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_coolnumber.boiler_tempdiffcool501/102181
2381Geo 5xxboiler173vpcoolingvalve/pump coolingbooleantrueswitch.boiler_valve/pump_coolingswitch.boiler_vpcooling5012191
2382Geo 5xxboiler173heatcableheating cablebooleantrueswitch.boiler_heating_cableswitch.boiler_heatcable5012201
2383Geo 5xxboiler173vc0valveVC0 valvebooleantrueswitch.boiler_VC0_valveswitch.boiler_vc0valve5012211
2384Geo 5xxboiler173primepumpprimary heatpumpbooleantrueswitch.boiler_primary_heatpumpswitch.boiler_primepump5012221
2385Geo 5xxboiler173primepumpmodprimary heatpump modulationuint8 (>=0<=100)%truenumber.boiler_primary_heatpump_modulationnumber.boiler_primepumpmod5012231
2386Geo 5xxboiler173hp3way3-way valvebooleantrueswitch.boiler_3-way_valveswitch.boiler_hp3way5012241
2387Geo 5xxboiler173elheatstep1el. heater step 1booleantrueswitch.boiler_el._heater_step_1switch.boiler_elheatstep15012251
2388Geo 5xxboiler173elheatstep2el. heater step 2booleantrueswitch.boiler_el._heater_step_2switch.boiler_elheatstep25012261
2389Geo 5xxboiler173elheatstep3el. heater step 3booleantrueswitch.boiler_el._heater_step_3switch.boiler_elheatstep35012271
2390Geo 5xxboiler173hpea0condensate reservoir heating (EA0)booleanfalsebinary_sensor.boiler_condensate_reservoir_heating_(EA0)binary_sensor.boiler_hpea05012281
2391Geo 5xxboiler173hppumpmodeprimary heatpump modeenum [auto\|continuous]trueselect.boiler_primary_heatpump_modeselect.boiler_hppumpmode5012291
2392Geo 5xxboiler173fanfanuint8 (>=20<=100)%truenumber.boiler_fannumber.boiler_fan5012301
2393Geo 5xxboiler173shutdownshutdowncmd [off\|on]truesensor.boiler_shutdownsensor.boiler_shutdown5012311
2394Geo 5xxboiler173alternatingopalternating operationbooleantrueswitch.boiler_dhw_alternating_operationswitch.boiler_dhw_alternatingop591151
2395Geo 5xxboiler173altopprioheatprioritise heating during dhwuint8 (>=20<=120)minutestruenumber.boiler_dhw_prioritise_heating_during_dhwnumber.boiler_dhw_altopprioheat591161
2396Geo 5xxboiler173altopprioprioritise dhw during heatinguint8 (>=30<=120)minutestruenumber.boiler_dhw_prioritise_dhw_during_heatingnumber.boiler_dhw_altopprio591171
2397Geo 5xxboiler173comfoffcomfort switch offuint8 (>=15<=65)Ctruenumber.boiler_dhw_comfort_switch_offnumber.boiler_dhw_comfoff591181
2398Geo 5xxboiler173ecooffeco switch offuint8 (>=15<=65)Ctruenumber.boiler_dhw_eco_switch_offnumber.boiler_dhw_ecooff591191
2399Geo 5xxboiler173ecoplusoffeco+ switch offuint8 (>=48<=63)Ctruenumber.boiler_dhw_eco+_switch_offnumber.boiler_dhw_ecoplusoff591201
2400Geo 5xxboiler173comfdiffcomfort diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_comfort_diffnumber.boiler_dhw_comfdiff591211
2401Geo 5xxboiler173ecodiffeco diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_eco_diffnumber.boiler_dhw_ecodiff591221
2402Geo 5xxboiler173ecoplusdiffeco+ diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_eco+_diffnumber.boiler_dhw_ecoplusdiff591231
2403Geo 5xxboiler173comfstopcomfort stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_comfort_stop_tempnumber.boiler_dhw_comfstop591241
2404Geo 5xxboiler173ecostopeco stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_eco_stop_tempnumber.boiler_dhw_ecostop591251
2405Geo 5xxboiler173ecoplusstopeco+ stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_eco+_stop_tempnumber.boiler_dhw_ecoplusstop591261
2406Geo 5xxboiler173hpcircpumpcirculation pump available during dhwbooleantrueswitch.boiler_dhw_circulation_pump_available_during_dhwswitch.boiler_dhw_hpcircpump591271
2407Geo 5xxboiler173tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
2408Geo 5xxboiler173settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
2409Geo 5xxboiler173seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
2410Geo 5xxboiler173seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
2411Geo 5xxboiler173tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
2412Geo 5xxboiler173seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
2413Geo 5xxboiler173seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
2414Geo 5xxboiler173solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
2415Geo 5xxboiler173typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
2416Geo 5xxboiler173comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
2417Geo 5xxboiler173comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
2418Geo 5xxboiler173flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
2419Geo 5xxboiler173chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
2420Geo 5xxboiler173maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
2421Geo 5xxboiler173maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
2422Geo 5xxboiler173circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
2423Geo 5xxboiler173chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
2424Geo 5xxboiler173hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
2425Geo 5xxboiler173hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
2426Geo 5xxboiler173disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
2427Geo 5xxboiler173circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
2428Geo 5xxboiler173circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
2429Geo 5xxboiler173curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
2430Geo 5xxboiler173curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
2431Geo 5xxboiler173curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
2432Geo 5xxboiler173storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
2433Geo 5xxboiler173storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
2434Geo 5xxboiler173activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
2435Geo 5xxboiler173onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
2436Geo 5xxboiler173disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
2437Geo 5xxboiler173chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
2438Geo 5xxboiler173rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
2439Geo 5xxboiler173tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
2440Geo 5xxboiler173activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
2441Geo 5xxboiler1733wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
2442Geo 5xxboiler173mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
2443Geo 5xxboiler173cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
2444Geo 5xxboiler173startsstartsuint24 (>=0<=16777213)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
2445Geo 5xxboiler173workmactive timetime (>=0<=16777213)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
2446Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
2447Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
2448Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
2449Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
2450Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
2451Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
2452Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
2453Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
2454Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
2455Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
2456Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
2457Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
2458Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
2459Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102321
2460Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012331
2461Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012341
2462Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102351
2463Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012361
2464Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012371
2465Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012381
2466Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012391
2467Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012401
2468Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012411
2469Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012421
2470Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102431
2471Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012441
2472Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012451
2473Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012461
2474Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012471
2475Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012481
2476Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012491
2477Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012501
2478Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012511
2479Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012521
2480Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012531
2481Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
2482Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
2483Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
2484Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
2485Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
2486Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
2487Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
2488Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
2489Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501231
2490Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501241
2491Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195burnstartsburner startsuint24 (>=0<=16777213)falsesensor.boiler_burner_startssensor.boiler_burnstarts501252
2492Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195burnworkmintotal burner operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501272
2493Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195burn2workminburner stage 2 operating timetime (>=0<=16777213)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501292
2494Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195heatworkmintotal heat operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501312
2495Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195heatstartsburner starts heatinguint24 (>=0<=16777213)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501332
2496Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195ubauptimetotal UBA operating timetime (>=0<=16777213)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501352
2497Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013728
2498Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501652
2499Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501671
2500Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2boiler195maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501682