1device namedevice typeproduct idshortnamefullnametype [options...] \| (min/max)uomwriteablediscovery entityid v3.4discovery entityidmodbus unit identifiermodbus blockmodbus scale factormodbus offsetmodbus count
2CS5800i, CS6800i, WLW176i, WLW186iboiler8resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
3CS5800i, CS6800i, WLW176i, WLW186iboiler8heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
4CS5800i, CS6800i, WLW176i, WLW186iboiler8heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
5CS5800i, CS6800i, WLW176i, WLW186iboiler8tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
6CS5800i, CS6800i, WLW176i, WLW186iboiler8selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
7CS5800i, CS6800i, WLW176i, WLW186iboiler8heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
8CS5800i, CS6800i, WLW176i, WLW186iboiler8outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
9CS5800i, CS6800i, WLW176i, WLW186iboiler8curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
10CS5800i, CS6800i, WLW176i, WLW186iboiler8rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
11CS5800i, CS6800i, WLW176i, WLW186iboiler8switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
12CS5800i, CS6800i, WLW176i, WLW186iboiler8syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
13CS5800i, CS6800i, WLW176i, WLW186iboiler8boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
14CS5800i, CS6800i, WLW176i, WLW186iboiler8headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
15CS5800i, CS6800i, WLW176i, WLW186iboiler8heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
16CS5800i, CS6800i, WLW176i, WLW186iboiler8heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
17CS5800i, CS6800i, WLW176i, WLW186iboiler8heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
18CS5800i, CS6800i, WLW176i, WLW186iboiler8pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
19CS5800i, CS6800i, WLW176i, WLW186iboiler8pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
20CS5800i, CS6800i, WLW176i, WLW186iboiler8pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
21CS5800i, CS6800i, WLW176i, WLW186iboiler8pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
22CS5800i, CS6800i, WLW176i, WLW186iboiler8pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
23CS5800i, CS6800i, WLW176i, WLW186iboiler8pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
24CS5800i, CS6800i, WLW176i, WLW186iboiler8selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
25CS5800i, CS6800i, WLW176i, WLW186iboiler8curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
26CS5800i, CS6800i, WLW176i, WLW186iboiler8burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
27CS5800i, CS6800i, WLW176i, WLW186iboiler8burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
28CS5800i, CS6800i, WLW176i, WLW186iboiler8burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
29CS5800i, CS6800i, WLW176i, WLW186iboiler8heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
30CS5800i, CS6800i, WLW176i, WLW186iboiler8heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
31CS5800i, CS6800i, WLW176i, WLW186iboiler8ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
32CS5800i, CS6800i, WLW176i, WLW186iboiler8lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
33CS5800i, CS6800i, WLW176i, WLW186iboiler8servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
34CS5800i, CS6800i, WLW176i, WLW186iboiler8servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
35CS5800i, CS6800i, WLW176i, WLW186iboiler8maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
36CS5800i, CS6800i, WLW176i, WLW186iboiler8maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
37CS5800i, CS6800i, WLW176i, WLW186iboiler8maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
38CS5800i, CS6800i, WLW176i, WLW186iboiler8maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
39CS5800i, CS6800i, WLW176i, WLW186iboiler8emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
40CS5800i, CS6800i, WLW176i, WLW186iboiler8emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
41CS5800i, CS6800i, WLW176i, WLW186iboiler8pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
42CS5800i, CS6800i, WLW176i, WLW186iboiler8pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
43CS5800i, CS6800i, WLW176i, WLW186iboiler8pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
44CS5800i, CS6800i, WLW176i, WLW186iboiler8pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
45CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
46CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.nrgenergyuint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_energysensor.boiler_dhw_nrg591/10002
47CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgheatenergy heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_heatingsensor.boiler_nrgheat501/100852
48CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgcoolenergy coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_coolingsensor.boiler_nrgcool501/100872
49CS5800i, CS6800i, WLW176i, WLW186iboiler8metertotalmeter totaluint24 (>=0<=167772)kWhfalsesensor.boiler_meter_totalsensor.boiler_metertotal501/100892
50CS5800i, CS6800i, WLW176i, WLW186iboiler8metercompmeter compressoruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_compressorsensor.boiler_metercomp501/100912
51CS5800i, CS6800i, WLW176i, WLW186iboiler8metereheatmeter e-heateruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_e-heatersensor.boiler_metereheat501/100932
52CS5800i, CS6800i, WLW176i, WLW186iboiler8meterheatmeter heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/100952
53CS5800i, CS6800i, WLW176i, WLW186iboiler8metercoolmeter coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_coolingsensor.boiler_metercool501/100972
54CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.metermeteruint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/10022
55CS5800i, CS6800i, WLW176i, WLW186iboiler8uptimetotalheatpump total uptimetime (>=0<=279620)minutesfalsesensor.boiler_heatpump_total_uptimesensor.boiler_uptimetotal501/60992
56CS5800i, CS6800i, WLW176i, WLW186iboiler8uptimecontroltotal operating time heattime (>=0<=279620)minutesfalsesensor.boiler_total_operating_time_heatsensor.boiler_uptimecontrol501/601012
57CS5800i, CS6800i, WLW176i, WLW186iboiler8uptimecompheatingoperating time compressor heatingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_heatingsensor.boiler_uptimecompheating501/601032
58CS5800i, CS6800i, WLW176i, WLW186iboiler8uptimecompcoolingoperating time compressor coolingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_coolingsensor.boiler_uptimecompcooling501/601052
59CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.uptimecompoperating time compressortime (>=0<=279620)minutesfalsesensor.boiler_dhw_operating_time_compressorsensor.boiler_dhw_uptimecomp591/6042
60CS5800i, CS6800i, WLW176i, WLW186iboiler8uptimecomppooloperating time compressor pooltime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_poolsensor.boiler_uptimecomppool501/601072
61CS5800i, CS6800i, WLW176i, WLW186iboiler8totalcompstartstotal compressor control startsuint24 (>=0<=16777214)falsesensor.boiler_total_compressor_control_startssensor.boiler_totalcompstarts5011092
62CS5800i, CS6800i, WLW176i, WLW186iboiler8heatingstartsheating control startsuint24 (>=0<=16777214)falsesensor.boiler_heating_control_startssensor.boiler_heatingstarts5011112
63CS5800i, CS6800i, WLW176i, WLW186iboiler8coolingstartscooling control startsuint24 (>=0<=16777214)falsesensor.boiler_cooling_control_startssensor.boiler_coolingstarts5011132
64CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.startshpstarts hpuint24 (>=0<=16777214)falsesensor.boiler_dhw_starts_hpsensor.boiler_dhw_startshp59162
65CS5800i, CS6800i, WLW176i, WLW186iboiler8poolstartspool control startsuint24 (>=0<=16777214)falsesensor.boiler_pool_control_startssensor.boiler_poolstarts5011152
66CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgconstotaltotal energy consumptionuint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_consumptionsensor.boiler_nrgconstotal5011172
67CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgconscomptotaltotal energy consumption compressoruint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_consumption_compressorsensor.boiler_nrgconscomptotal5011192
68CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgconscompheatingenergy consumption compressor heatinguint24 (>=0<=16777214)kWhfalsesensor.boiler_energy_consumption_compressor_heatingsensor.boiler_nrgconscompheating5011212
69CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.nrgconscompenergy consumption compressoruint24 (>=0<=16777214)kWhfalsesensor.boiler_dhw_energy_consumption_compressorsensor.boiler_dhw_nrgconscomp59182
70CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgconscompcoolingenergy consumption compressor coolinguint24 (>=0<=16777214)kWhfalsesensor.boiler_energy_consumption_compressor_coolingsensor.boiler_nrgconscompcooling5011232
71CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgconscomppoolenergy consumption compressor pooluint24 (>=0<=16777214)kWhfalsesensor.boiler_energy_consumption_compressor_poolsensor.boiler_nrgconscomppool5011252
72CS5800i, CS6800i, WLW176i, WLW186iboiler8auxelecheatnrgconstotaltotal aux elec. heater energy consumptionuint24 (>=0<=16777214)kWhfalsesensor.boiler_total_aux_elec._heater_energy_consumptionsensor.boiler_auxelecheatnrgconstotal5011272
73CS5800i, CS6800i, WLW176i, WLW186iboiler8auxelecheatnrgconsheatingaux elec. heater energy consumption heatinguint24 (>=0<=16777214)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_heatingsensor.boiler_auxelecheatnrgconsheating5011292
74CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.auxelecheatnrgconsaux elec. heater energy consumptionuint24 (>=0<=16777214)kWhfalsesensor.boiler_dhw_aux_elec._heater_energy_consumptionsensor.boiler_dhw_auxelecheatnrgcons591102
75CS5800i, CS6800i, WLW176i, WLW186iboiler8auxelecheatnrgconspoolaux elec. heater energy consumption pooluint24 (>=0<=16777214)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_poolsensor.boiler_auxelecheatnrgconspool5011312
76CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgsupptotaltotal energy supplieduint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_suppliedsensor.boiler_nrgsupptotal5011332
77CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgsuppheatingtotal energy supplied heatinguint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_supplied_heatingsensor.boiler_nrgsuppheating5011352
78CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.nrgsupptotal energy warm supplieduint24 (>=0<=16777214)kWhfalsesensor.boiler_dhw_total_energy_warm_suppliedsensor.boiler_dhw_nrgsupp591122
79CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgsuppcoolingtotal energy supplied coolinguint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_supplied_coolingsensor.boiler_nrgsuppcooling5011372
80CS5800i, CS6800i, WLW176i, WLW186iboiler8nrgsupppooltotal energy supplied pooluint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_supplied_poolsensor.boiler_nrgsupppool5011392
81CS5800i, CS6800i, WLW176i, WLW186iboiler8hppowercompressor power outputuint16 (>=0<=3199)kWfalsesensor.boiler_compressor_power_outputsensor.boiler_hppower501/101411
82CS5800i, CS6800i, WLW176i, WLW186iboiler8hpmaxpowercompressor max poweruint8 (>=0<=100)%truenumber.boiler_compressor_max_powernumber.boiler_hpmaxpower5011421
83CS5800i, CS6800i, WLW176i, WLW186iboiler8pvmaxcomppv compressor max poweruint8 (>=0<=25)kWtruenumber.boiler_pv_compressor_max_powernumber.boiler_pvmaxcomp501/101431
84CS5800i, CS6800i, WLW176i, WLW186iboiler8powerreductionpower reductionuint8 (>=30<=60)%truenumber.boiler_power_reductionnumber.boiler_powerreduction50101441
85CS5800i, CS6800i, WLW176i, WLW186iboiler8hpsetdiffpressset differential pressureuint8 (>=150<=750)mbartruenumber.boiler_set_differential_pressurenumber.boiler_hpsetdiffpress50501451
86CS5800i, CS6800i, WLW176i, WLW186iboiler8hpcomponhp compressorbooleanfalsebinary_sensor.boiler_hp_compressorbinary_sensor.boiler_hpcompon5011461
87CS5800i, CS6800i, WLW176i, WLW186iboiler8hpactivitycompressor activityenum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm]falsesensor.boiler_compressor_activitysensor.boiler_hpactivity5011471
88CS5800i, CS6800i, WLW176i, WLW186iboiler8hpbrinepumpspdbrine pump speeduint8 (>=0<=100)%falsesensor.boiler_brine_pump_speedsensor.boiler_hpbrinepumpspd5011481
89CS5800i, CS6800i, WLW176i, WLW186iboiler8hpswitchvalveswitch valvebooleanfalsebinary_sensor.boiler_switch_valvebinary_sensor.boiler_hpswitchvalve5011491
90CS5800i, CS6800i, WLW176i, WLW186iboiler8hpcompspdcompressor speeduint8 (>=0<=100)%falsesensor.boiler_compressor_speedsensor.boiler_hpcompspd5011501
91CS5800i, CS6800i, WLW176i, WLW186iboiler8hpcircspdcirculation pump speeduint8 (>=0<=100)%falsesensor.boiler_circulation_pump_speedsensor.boiler_hpcircspd5011511
92CS5800i, CS6800i, WLW176i, WLW186iboiler8hpbrineinbrine in/evaporatorint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_in/evaporatorsensor.boiler_hpbrinein501/101521
93CS5800i, CS6800i, WLW176i, WLW186iboiler8hpbrineoutbrine out/condenserint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_out/condensersensor.boiler_hpbrineout501/101531
94CS5800i, CS6800i, WLW176i, WLW186iboiler8hptc0heat carrier return (TC0)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_return_(TC0)sensor.boiler_hptc0501/101541
95CS5800i, CS6800i, WLW176i, WLW186iboiler8hptc1heat carrier forward (TC1)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_forward_(TC1)sensor.boiler_hptc1501/101551
96CS5800i, CS6800i, WLW176i, WLW186iboiler8hptc3condenser temperature (TC3)int16 (>=-3199<=3199)Cfalsesensor.boiler_condenser_temperature_(TC3)sensor.boiler_hptc3501/101561
97CS5800i, CS6800i, WLW176i, WLW186iboiler8hptr1compressor temperature (TR1)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_temperature_(TR1)sensor.boiler_hptr1501/101571
98CS5800i, CS6800i, WLW176i, WLW186iboiler8hptr3refrigerant temperature liquid side (condenser output) (TR3)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3)sensor.boiler_hptr3501/101581
99CS5800i, CS6800i, WLW176i, WLW186iboiler8hptr4evaporator inlet temperature (TR4)int16 (>=-3199<=3199)Cfalsesensor.boiler_evaporator_inlet_temperature_(TR4)sensor.boiler_hptr4501/101591
100CS5800i, CS6800i, WLW176i, WLW186iboiler8hptr5compressor inlet temperature (TR5)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_inlet_temperature_(TR5)sensor.boiler_hptr5501/101601
101CS5800i, CS6800i, WLW176i, WLW186iboiler8hptr6compressor outlet temperature (TR6)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_outlet_temperature_(TR6)sensor.boiler_hptr6501/101611
102CS5800i, CS6800i, WLW176i, WLW186iboiler8hptr7refrigerant temperature gas side (condenser input) (TR7)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7)sensor.boiler_hptr7501/101621
103CS5800i, CS6800i, WLW176i, WLW186iboiler8hptl2air inlet temperature (TL2)int16 (>=-3199<=3199)Cfalsesensor.boiler_air_inlet_temperature_(TL2)sensor.boiler_hptl2501/101631
104CS5800i, CS6800i, WLW176i, WLW186iboiler8hppl1low pressure side temperature (PL1)int16 (>=-3199<=3199)Cfalsesensor.boiler_low_pressure_side_temperature_(PL1)sensor.boiler_hppl1501/101641
105CS5800i, CS6800i, WLW176i, WLW186iboiler8hpph1high pressure side temperature (PH1)int16 (>=-3199<=3199)Cfalsesensor.boiler_high_pressure_side_temperature_(PH1)sensor.boiler_hpph1501/101651
106CS5800i, CS6800i, WLW176i, WLW186iboiler8hpta4drain pan temp (TA4)int16 (>=-3199<=3199)Cfalsesensor.boiler_drain_pan_temp_(TA4)sensor.boiler_hpta4501/101661
107CS5800i, CS6800i, WLW176i, WLW186iboiler8hptw1reservoir temp (TW1)int16 (>=-3199<=3199)Cfalsesensor.boiler_reservoir_temp_(TW1)sensor.boiler_hptw1501/101671
108CS5800i, CS6800i, WLW176i, WLW186iboiler8poolsettemppool set temperatureuint8 (>=0<=127)Ctruenumber.boiler_pool_set_temperaturenumber.boiler_poolsettemp501/21681
109CS5800i, CS6800i, WLW176i, WLW186iboiler8hp4way4-way valve (VR4)enum [cooling & defrost\|heating & dhw]falsesensor.boiler_4-way_valve_(VR4)sensor.boiler_hp4way5011691
110CS5800i, CS6800i, WLW176i, WLW186iboiler8hpin1input 1 statebooleanfalsebinary_sensor.boiler_input_1_statebinary_sensor.boiler_hpin15011701
111CS5800i, CS6800i, WLW176i, WLW186iboiler8hpin1optinput 1 optionsstringtruesensor.boiler_input_1_optionssensor.boiler_hpin1opt5011718
112CS5800i, CS6800i, WLW176i, WLW186iboiler8hpin2input 2 statebooleanfalsebinary_sensor.boiler_input_2_statebinary_sensor.boiler_hpin25011791
113CS5800i, CS6800i, WLW176i, WLW186iboiler8hpin2optinput 2 optionsstringtruesensor.boiler_input_2_optionssensor.boiler_hpin2opt5011808
114CS5800i, CS6800i, WLW176i, WLW186iboiler8hpin3input 3 statebooleanfalsebinary_sensor.boiler_input_3_statebinary_sensor.boiler_hpin35011881
115CS5800i, CS6800i, WLW176i, WLW186iboiler8hpin3optinput 3 optionsstringtruesensor.boiler_input_3_optionssensor.boiler_hpin3opt5011898
116CS5800i, CS6800i, WLW176i, WLW186iboiler8hpin4input 4 statebooleanfalsebinary_sensor.boiler_input_4_statebinary_sensor.boiler_hpin45011971
117CS5800i, CS6800i, WLW176i, WLW186iboiler8hpin4optinput 4 optionsstringtruesensor.boiler_input_4_optionssensor.boiler_hpin4opt5011988
118CS5800i, CS6800i, WLW176i, WLW186iboiler8maxheatcompheat limit compressorenum [0 kW\|3 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_compressorselect.boiler_maxheatcomp5012061
119CS5800i, CS6800i, WLW176i, WLW186iboiler8maxheatheatheat limit heatingenum [3 kW\|6 kW\|9 kW]trueselect.boiler_heat_limit_heatingselect.boiler_maxheatheat5012071
120CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.maxheatheat limitenum [3 kW\|6 kW\|9 kW]trueselect.boiler_dhw_heat_limitselect.boiler_dhw_maxheat591141
121CS5800i, CS6800i, WLW176i, WLW186iboiler8auxheatersourceaux heater sourceenum [not installed\|electric heater\|exclusive\|parallel\|hybrid]trueselect.boiler_aux_heater_sourceselect.boiler_auxheatersource5012081
122CS5800i, CS6800i, WLW176i, WLW186iboiler8pvcoolingcooling only with PVbooleantrueswitch.boiler_cooling_only_with_PVswitch.boiler_pvcooling5012091
123CS5800i, CS6800i, WLW176i, WLW186iboiler8auxheateronlyaux heater onlybooleantrueswitch.boiler_aux_heater_onlyswitch.boiler_auxheateronly5012101
124CS5800i, CS6800i, WLW176i, WLW186iboiler8auxheateroffdisable aux heaterbooleantrueswitch.boiler_disable_aux_heaterswitch.boiler_auxheateroff5012111
125CS5800i, CS6800i, WLW176i, WLW186iboiler8auxheaterstatusaux heater statusenum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm]falsesensor.boiler_aux_heater_statussensor.boiler_auxheaterstatus5012121
126CS5800i, CS6800i, WLW176i, WLW186iboiler8auxheaterlevelaux heater leveluint8 (>=0<=100)%falsesensor.boiler_aux_heater_levelsensor.boiler_auxheaterlevel5012131
127CS5800i, CS6800i, WLW176i, WLW186iboiler8auxheaterdelayaux heater on delayuint16 (>=10<=1000)K*mintruenumber.boiler_aux_heater_on_delaynumber.boiler_auxheaterdelay50102141
128CS5800i, CS6800i, WLW176i, WLW186iboiler8auxmaxlimitaux heater max limituint8 (>=0<=10)Ktruenumber.boiler_aux_heater_max_limitnumber.boiler_auxmaxlimit501/102151
129CS5800i, CS6800i, WLW176i, WLW186iboiler8auxlimitstartaux heater limit startuint8 (>=0<=10)Ktruenumber.boiler_aux_heater_limit_startnumber.boiler_auxlimitstart501/102161
130CS5800i, CS6800i, WLW176i, WLW186iboiler8auxheatrmodeaux heater modeenum [eco\|comfort]trueselect.boiler_aux_heater_modeselect.boiler_auxheatrmode5012171
131CS5800i, CS6800i, WLW176i, WLW186iboiler8hphystheaton/off hyst heatuint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_heatnumber.boiler_hphystheat5052181
132CS5800i, CS6800i, WLW176i, WLW186iboiler8hphystcoolon/off hyst cooluint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_coolnumber.boiler_hphystcool5052191
133CS5800i, CS6800i, WLW176i, WLW186iboiler8hphystpoolon/off hyst pooluint16 (>=50<=1500)K*mintruenumber.boiler_on/off_hyst_poolnumber.boiler_hphystpool5052201
134CS5800i, CS6800i, WLW176i, WLW186iboiler8silentmodesilent modeenum [off\|auto\|on]trueselect.boiler_silent_modeselect.boiler_silentmode5012211
135CS5800i, CS6800i, WLW176i, WLW186iboiler8silentfromsilent mode fromuint8 (>=0<=3810)minutestruenumber.boiler_silent_mode_fromnumber.boiler_silentfrom50152221
136CS5800i, CS6800i, WLW176i, WLW186iboiler8silenttosilent mode touint8 (>=0<=3810)minutestruenumber.boiler_silent_mode_tonumber.boiler_silentto50152231
137CS5800i, CS6800i, WLW176i, WLW186iboiler8mintempsilentmin outside temp for silent modeint8 (>=-126<=126)Ctruenumber.boiler_min_outside_temp_for_silent_modenumber.boiler_mintempsilent5012241
138CS5800i, CS6800i, WLW176i, WLW186iboiler8tempparmodeoutside temp parallel modeint8 (>=-126<=126)Ctruenumber.boiler_outside_temp_parallel_modenumber.boiler_tempparmode5012251
139CS5800i, CS6800i, WLW176i, WLW186iboiler8auxheatmixaux heater mixing valveint8 (>=-100<=100)%falsesensor.boiler_aux_heater_mixing_valvesensor.boiler_auxheatmix5012261
140CS5800i, CS6800i, WLW176i, WLW186iboiler8tempdiffheattemp diff TC3/TC0 heatuint8 (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_heatnumber.boiler_tempdiffheat501/102271
141CS5800i, CS6800i, WLW176i, WLW186iboiler8tempdiffcooltemp diff TC3/TC0 cooluint8 (>=2<=10)Ktruenumber.boiler_temp_diff_TC3/TC0_coolnumber.boiler_tempdiffcool501/102281
142CS5800i, CS6800i, WLW176i, WLW186iboiler8vpcoolingvalve/pump coolingbooleantrueswitch.boiler_valve/pump_coolingswitch.boiler_vpcooling5012291
143CS5800i, CS6800i, WLW176i, WLW186iboiler8heatcableheating cablebooleantrueswitch.boiler_heating_cableswitch.boiler_heatcable5012301
144CS5800i, CS6800i, WLW176i, WLW186iboiler8vc0valveVC0 valvebooleantrueswitch.boiler_VC0_valveswitch.boiler_vc0valve5012311
145CS5800i, CS6800i, WLW176i, WLW186iboiler8primepumpprimary heatpumpbooleantrueswitch.boiler_primary_heatpumpswitch.boiler_primepump5012321
146CS5800i, CS6800i, WLW176i, WLW186iboiler8primepumpmodprimary heatpump modulationuint8 (>=0<=100)%truenumber.boiler_primary_heatpump_modulationnumber.boiler_primepumpmod5012331
147CS5800i, CS6800i, WLW176i, WLW186iboiler8hp3way3-way valvebooleantrueswitch.boiler_3-way_valveswitch.boiler_hp3way5012341
148CS5800i, CS6800i, WLW176i, WLW186iboiler8elheatstep1el. heater step 1booleantrueswitch.boiler_el._heater_step_1switch.boiler_elheatstep15012351
149CS5800i, CS6800i, WLW176i, WLW186iboiler8elheatstep2el. heater step 2booleantrueswitch.boiler_el._heater_step_2switch.boiler_elheatstep25012361
150CS5800i, CS6800i, WLW176i, WLW186iboiler8elheatstep3el. heater step 3booleantrueswitch.boiler_el._heater_step_3switch.boiler_elheatstep35012371
151CS5800i, CS6800i, WLW176i, WLW186iboiler8hpea0condensate reservoir heating (EA0)booleanfalsebinary_sensor.boiler_condensate_reservoir_heating_(EA0)binary_sensor.boiler_hpea05012381
152CS5800i, CS6800i, WLW176i, WLW186iboiler8hppumpmodeprimary heatpump modeenum [auto\|continuous]trueselect.boiler_primary_heatpump_modeselect.boiler_hppumpmode5012391
153CS5800i, CS6800i, WLW176i, WLW186iboiler8fanfanuint8 (>=20<=100)%truenumber.boiler_fannumber.boiler_fan5012401
154CS5800i, CS6800i, WLW176i, WLW186iboiler8shutdownshutdowncmd [off\|on]truesensor.boiler_shutdownsensor.boiler_shutdown5012411
155CS5800i, CS6800i, WLW176i, WLW186iboiler8hpcurrpowercompressor current poweruint16 (>=0<=31999)Wfalsesensor.boiler_compressor_current_powersensor.boiler_hpcurrpower5012421
156CS5800i, CS6800i, WLW176i, WLW186iboiler8hppowerlimitpower limituint16 (>=0<=31999)Wtruenumber.boiler_power_limitnumber.boiler_hppowerlimit5012431
157CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.alternatingopalternating operationbooleantrueswitch.boiler_dhw_alternating_operationswitch.boiler_dhw_alternatingop591151
158CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.altopprioheatprioritise heating during dhwuint8 (>=20<=120)minutestruenumber.boiler_dhw_prioritise_heating_during_dhwnumber.boiler_dhw_altopprioheat591161
159CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.altopprioprioritise dhw during heatinguint8 (>=30<=120)minutestruenumber.boiler_dhw_prioritise_dhw_during_heatingnumber.boiler_dhw_altopprio591171
160CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.comfoffcomfort switch offuint8 (>=15<=65)Ctruenumber.boiler_dhw_comfort_switch_offnumber.boiler_dhw_comfoff591181
161CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.ecooffeco switch offuint8 (>=15<=65)Ctruenumber.boiler_dhw_eco_switch_offnumber.boiler_dhw_ecooff591191
162CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.ecoplusoffeco+ switch offuint8 (>=48<=63)Ctruenumber.boiler_dhw_eco+_switch_offnumber.boiler_dhw_ecoplusoff591201
163CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.comfdiffcomfort diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_comfort_diffnumber.boiler_dhw_comfdiff591211
164CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.ecodiffeco diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_eco_diffnumber.boiler_dhw_ecodiff591221
165CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.ecoplusdiffeco+ diffuint8 (>=6<=12)Ktruenumber.boiler_dhw_eco+_diffnumber.boiler_dhw_ecoplusdiff591231
166CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.comfstopcomfort stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_comfort_stop_tempnumber.boiler_dhw_comfstop591241
167CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.ecostopeco stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_eco_stop_tempnumber.boiler_dhw_ecostop591251
168CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.ecoplusstopeco+ stop tempuint8 (>=0<=254)Ctruenumber.boiler_dhw_eco+_stop_tempnumber.boiler_dhw_ecoplusstop591261
169CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.hpcircpumpcirculation pump available during dhwbooleantrueswitch.boiler_dhw_circulation_pump_available_during_dhwswitch.boiler_dhw_hpcircpump591271
170CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
171CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
172CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
173CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
174CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
175CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
176CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
177CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
178CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
179CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
180CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
181CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
182CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
183CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
184CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
185CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
186CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
187CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
188CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
189CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
190CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
191CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
192CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
193CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
194CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
195CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
196CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
197CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
198CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
199CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
200CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
201CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
202CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
203CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
204CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
205CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
206CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
207CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
208CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
209CS5800i, CS6800i, WLW176i, WLW186iboiler8dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
210C1200Wboiler12resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
211C1200Wboiler12heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
212C1200Wboiler12heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
213C1200Wboiler12tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
214C1200Wboiler12selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
215C1200Wboiler12heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
216C1200Wboiler12outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
217C1200Wboiler12curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
218C1200Wboiler12rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
219C1200Wboiler12switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
220C1200Wboiler12syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
221C1200Wboiler12boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
222C1200Wboiler12headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
223C1200Wboiler12exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
224C1200Wboiler12burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
225C1200Wboiler12burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
226C1200Wboiler12flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
227C1200Wboiler12fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
228C1200Wboiler12ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
229C1200Wboiler12oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
230C1200Wboiler12burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
231C1200Wboiler12burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
232C1200Wboiler12burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
233C1200Wboiler12absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
234C1200Wboiler12heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
235C1200Wboiler12boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
236C1200Wboiler12boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
237C1200Wboiler12boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
238C1200Wboiler12boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
239C1200Wboiler12curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
240C1200Wboiler12curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
241C1200Wboiler12curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
242C1200Wboiler12summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
243C1200Wboiler12nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
244C1200Wboiler12nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
245C1200Wboiler12heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
246C1200Wboiler12heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
247C1200Wboiler12heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
248C1200Wboiler12pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
249C1200Wboiler12pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
250C1200Wboiler12pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
251C1200Wboiler12pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
252C1200Wboiler12pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
253C1200Wboiler12pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
254C1200Wboiler12selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
255C1200Wboiler12curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
256C1200Wboiler12burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
257C1200Wboiler12burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
258C1200Wboiler12burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
259C1200Wboiler12heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
260C1200Wboiler12heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
261C1200Wboiler12ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
262C1200Wboiler12lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
263C1200Wboiler12servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
264C1200Wboiler12servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
265C1200Wboiler12maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
266C1200Wboiler12maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
267C1200Wboiler12maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
268C1200Wboiler12maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
269C1200Wboiler12emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
270C1200Wboiler12emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
271C1200Wboiler12pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
272C1200Wboiler12pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
273C1200Wboiler12pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
274C1200Wboiler12pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
275C1200Wboiler12meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
276C1200Wboiler12dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
277C1200Wboiler12gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
278C1200Wboiler12dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
279C1200Wboiler12nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
280C1200Wboiler12dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
281C1200Wboiler12dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
282C1200Wboiler12dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
283C1200Wboiler12dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
284C1200Wboiler12dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
285C1200Wboiler12dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
286C1200Wboiler12dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
287C1200Wboiler12dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
288C1200Wboiler12dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
289C1200Wboiler12dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
290C1200Wboiler12dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
291C1200Wboiler12dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
292C1200Wboiler12dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
293C1200Wboiler12dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
294C1200Wboiler12dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
295C1200Wboiler12dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
296C1200Wboiler12dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
297C1200Wboiler12dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
298C1200Wboiler12dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
299C1200Wboiler12dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
300C1200Wboiler12dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
301C1200Wboiler12dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
302C1200Wboiler12dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
303C1200Wboiler12dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
304C1200Wboiler12dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
305C1200Wboiler12dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
306C1200Wboiler12dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
307C1200Wboiler12dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
308C1200Wboiler12dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
309C1200Wboiler12dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
310C1200Wboiler12dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
311C1200Wboiler12dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
312C1200Wboiler12dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
313C1200Wboiler12dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
314C1200Wboiler12dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
315C1200Wboiler12dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
316C1200Wboiler12dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
317C1200Wboiler12dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
318C1200Wboiler12dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
319C1200Wboiler12dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
320C1200Wboiler12dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
321C1200Wboiler12nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
322C1200Wboiler12nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
323C1200Wboiler12nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
324C1200Wboiler12dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
325CS5800iGboiler16resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
326CS5800iGboiler16heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
327CS5800iGboiler16heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
328CS5800iGboiler16tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
329CS5800iGboiler16selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
330CS5800iGboiler16heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
331CS5800iGboiler16outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
332CS5800iGboiler16curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
333CS5800iGboiler16rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
334CS5800iGboiler16switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
335CS5800iGboiler16syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
336CS5800iGboiler16boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
337CS5800iGboiler16headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
338CS5800iGboiler16exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
339CS5800iGboiler16burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
340CS5800iGboiler16burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
341CS5800iGboiler16flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
342CS5800iGboiler16fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
343CS5800iGboiler16ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
344CS5800iGboiler16oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
345CS5800iGboiler16burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
346CS5800iGboiler16burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
347CS5800iGboiler16burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
348CS5800iGboiler16absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
349CS5800iGboiler16heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
350CS5800iGboiler16boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
351CS5800iGboiler16boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
352CS5800iGboiler16boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
353CS5800iGboiler16boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
354CS5800iGboiler16curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
355CS5800iGboiler16curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
356CS5800iGboiler16curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
357CS5800iGboiler16summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
358CS5800iGboiler16nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
359CS5800iGboiler16nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
360CS5800iGboiler16heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
361CS5800iGboiler16heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
362CS5800iGboiler16heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
363CS5800iGboiler16pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
364CS5800iGboiler16pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
365CS5800iGboiler16pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
366CS5800iGboiler16pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
367CS5800iGboiler16pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
368CS5800iGboiler16pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
369CS5800iGboiler16selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
370CS5800iGboiler16curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
371CS5800iGboiler16burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
372CS5800iGboiler16burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
373CS5800iGboiler16burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
374CS5800iGboiler16heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
375CS5800iGboiler16heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
376CS5800iGboiler16ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
377CS5800iGboiler16lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
378CS5800iGboiler16servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
379CS5800iGboiler16servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
380CS5800iGboiler16maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
381CS5800iGboiler16maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
382CS5800iGboiler16maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
383CS5800iGboiler16maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
384CS5800iGboiler16emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
385CS5800iGboiler16emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
386CS5800iGboiler16pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
387CS5800iGboiler16pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
388CS5800iGboiler16pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
389CS5800iGboiler16pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
390CS5800iGboiler16meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
391CS5800iGboiler16dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
392CS5800iGboiler16gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
393CS5800iGboiler16dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
394CS5800iGboiler16nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
395CS5800iGboiler16dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
396CS5800iGboiler16dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
397CS5800iGboiler16dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
398CS5800iGboiler16dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
399CS5800iGboiler16dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
400CS5800iGboiler16dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
401CS5800iGboiler16dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
402CS5800iGboiler16dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
403CS5800iGboiler16dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
404CS5800iGboiler16dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
405CS5800iGboiler16dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
406CS5800iGboiler16dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
407CS5800iGboiler16dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
408CS5800iGboiler16dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
409CS5800iGboiler16dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
410CS5800iGboiler16dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
411CS5800iGboiler16dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
412CS5800iGboiler16dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
413CS5800iGboiler16dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
414CS5800iGboiler16dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
415CS5800iGboiler16dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
416CS5800iGboiler16dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
417CS5800iGboiler16dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
418CS5800iGboiler16dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
419CS5800iGboiler16dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
420CS5800iGboiler16dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
421CS5800iGboiler16dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
422CS5800iGboiler16dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
423CS5800iGboiler16dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
424CS5800iGboiler16dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
425CS5800iGboiler16dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
426CS5800iGboiler16dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
427CS5800iGboiler16dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
428CS5800iGboiler16dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
429CS5800iGboiler16dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
430CS5800iGboiler16dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
431CS5800iGboiler16dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
432CS5800iGboiler16dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
433CS5800iGboiler16dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
434CS5800iGboiler16dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
435CS5800iGboiler16dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
436CS5800iGboiler16nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
437CS5800iGboiler16nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
438CS5800iGboiler16nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
439CS5800iGboiler16dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
440BK13/BK15, Smartline, GB1*2boiler64resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
441BK13/BK15, Smartline, GB1*2boiler64heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
442BK13/BK15, Smartline, GB1*2boiler64heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
443BK13/BK15, Smartline, GB1*2boiler64tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
444BK13/BK15, Smartline, GB1*2boiler64selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
445BK13/BK15, Smartline, GB1*2boiler64heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
446BK13/BK15, Smartline, GB1*2boiler64outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
447BK13/BK15, Smartline, GB1*2boiler64curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
448BK13/BK15, Smartline, GB1*2boiler64rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
449BK13/BK15, Smartline, GB1*2boiler64switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
450BK13/BK15, Smartline, GB1*2boiler64syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
451BK13/BK15, Smartline, GB1*2boiler64boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
452BK13/BK15, Smartline, GB1*2boiler64headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
453BK13/BK15, Smartline, GB1*2boiler64exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
454BK13/BK15, Smartline, GB1*2boiler64burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
455BK13/BK15, Smartline, GB1*2boiler64burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
456BK13/BK15, Smartline, GB1*2boiler64flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
457BK13/BK15, Smartline, GB1*2boiler64fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
458BK13/BK15, Smartline, GB1*2boiler64ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
459BK13/BK15, Smartline, GB1*2boiler64oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
460BK13/BK15, Smartline, GB1*2boiler64burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
461BK13/BK15, Smartline, GB1*2boiler64burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
462BK13/BK15, Smartline, GB1*2boiler64burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
463BK13/BK15, Smartline, GB1*2boiler64absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
464BK13/BK15, Smartline, GB1*2boiler64heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
465BK13/BK15, Smartline, GB1*2boiler64boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
466BK13/BK15, Smartline, GB1*2boiler64boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
467BK13/BK15, Smartline, GB1*2boiler64boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
468BK13/BK15, Smartline, GB1*2boiler64boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
469BK13/BK15, Smartline, GB1*2boiler64curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
470BK13/BK15, Smartline, GB1*2boiler64curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
471BK13/BK15, Smartline, GB1*2boiler64curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
472BK13/BK15, Smartline, GB1*2boiler64summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
473BK13/BK15, Smartline, GB1*2boiler64nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
474BK13/BK15, Smartline, GB1*2boiler64nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
475BK13/BK15, Smartline, GB1*2boiler64heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
476BK13/BK15, Smartline, GB1*2boiler64heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
477BK13/BK15, Smartline, GB1*2boiler64heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
478BK13/BK15, Smartline, GB1*2boiler64pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
479BK13/BK15, Smartline, GB1*2boiler64pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
480BK13/BK15, Smartline, GB1*2boiler64pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
481BK13/BK15, Smartline, GB1*2boiler64pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
482BK13/BK15, Smartline, GB1*2boiler64pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
483BK13/BK15, Smartline, GB1*2boiler64pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
484BK13/BK15, Smartline, GB1*2boiler64selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
485BK13/BK15, Smartline, GB1*2boiler64curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
486BK13/BK15, Smartline, GB1*2boiler64burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
487BK13/BK15, Smartline, GB1*2boiler64burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
488BK13/BK15, Smartline, GB1*2boiler64burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
489BK13/BK15, Smartline, GB1*2boiler64heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
490BK13/BK15, Smartline, GB1*2boiler64heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
491BK13/BK15, Smartline, GB1*2boiler64ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
492BK13/BK15, Smartline, GB1*2boiler64lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
493BK13/BK15, Smartline, GB1*2boiler64servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
494BK13/BK15, Smartline, GB1*2boiler64servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
495BK13/BK15, Smartline, GB1*2boiler64maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
496BK13/BK15, Smartline, GB1*2boiler64maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
497BK13/BK15, Smartline, GB1*2boiler64maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
498BK13/BK15, Smartline, GB1*2boiler64maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
499BK13/BK15, Smartline, GB1*2boiler64emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
500BK13/BK15, Smartline, GB1*2boiler64emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
501BK13/BK15, Smartline, GB1*2boiler64pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
502BK13/BK15, Smartline, GB1*2boiler64pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
503BK13/BK15, Smartline, GB1*2boiler64pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
504BK13/BK15, Smartline, GB1*2boiler64pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
505BK13/BK15, Smartline, GB1*2boiler64meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
506BK13/BK15, Smartline, GB1*2boiler64dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
507BK13/BK15, Smartline, GB1*2boiler64gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
508BK13/BK15, Smartline, GB1*2boiler64dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
509BK13/BK15, Smartline, GB1*2boiler64nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
510BK13/BK15, Smartline, GB1*2boiler64dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
511BK13/BK15, Smartline, GB1*2boiler64dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
512BK13/BK15, Smartline, GB1*2boiler64dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
513BK13/BK15, Smartline, GB1*2boiler64dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
514BK13/BK15, Smartline, GB1*2boiler64dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
515BK13/BK15, Smartline, GB1*2boiler64dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
516BK13/BK15, Smartline, GB1*2boiler64dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
517BK13/BK15, Smartline, GB1*2boiler64dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
518BK13/BK15, Smartline, GB1*2boiler64dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
519BK13/BK15, Smartline, GB1*2boiler64dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
520BK13/BK15, Smartline, GB1*2boiler64dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
521BK13/BK15, Smartline, GB1*2boiler64dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
522BK13/BK15, Smartline, GB1*2boiler64dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
523BK13/BK15, Smartline, GB1*2boiler64dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
524BK13/BK15, Smartline, GB1*2boiler64dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
525BK13/BK15, Smartline, GB1*2boiler64dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
526BK13/BK15, Smartline, GB1*2boiler64dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
527BK13/BK15, Smartline, GB1*2boiler64dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
528BK13/BK15, Smartline, GB1*2boiler64dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
529BK13/BK15, Smartline, GB1*2boiler64dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
530BK13/BK15, Smartline, GB1*2boiler64dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
531BK13/BK15, Smartline, GB1*2boiler64dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
532BK13/BK15, Smartline, GB1*2boiler64dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
533BK13/BK15, Smartline, GB1*2boiler64dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
534BK13/BK15, Smartline, GB1*2boiler64dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
535BK13/BK15, Smartline, GB1*2boiler64dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
536BK13/BK15, Smartline, GB1*2boiler64dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
537BK13/BK15, Smartline, GB1*2boiler64dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
538BK13/BK15, Smartline, GB1*2boiler64dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
539BK13/BK15, Smartline, GB1*2boiler64dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
540BK13/BK15, Smartline, GB1*2boiler64dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
541BK13/BK15, Smartline, GB1*2boiler64dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
542BK13/BK15, Smartline, GB1*2boiler64dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
543BK13/BK15, Smartline, GB1*2boiler64dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
544BK13/BK15, Smartline, GB1*2boiler64dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
545BK13/BK15, Smartline, GB1*2boiler64dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
546BK13/BK15, Smartline, GB1*2boiler64dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
547BK13/BK15, Smartline, GB1*2boiler64dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
548BK13/BK15, Smartline, GB1*2boiler64dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
549BK13/BK15, Smartline, GB1*2boiler64dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
550BK13/BK15, Smartline, GB1*2boiler64dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
551BK13/BK15, Smartline, GB1*2boiler64nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
552BK13/BK15, Smartline, GB1*2boiler64nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
553BK13/BK15, Smartline, GB1*2boiler64nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
554BK13/BK15, Smartline, GB1*2boiler64dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
555Logano GB1*5, Logamatic MC10boiler72resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
556Logano GB1*5, Logamatic MC10boiler72heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
557Logano GB1*5, Logamatic MC10boiler72heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
558Logano GB1*5, Logamatic MC10boiler72tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
559Logano GB1*5, Logamatic MC10boiler72selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
560Logano GB1*5, Logamatic MC10boiler72heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
561Logano GB1*5, Logamatic MC10boiler72outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
562Logano GB1*5, Logamatic MC10boiler72curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
563Logano GB1*5, Logamatic MC10boiler72rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
564Logano GB1*5, Logamatic MC10boiler72switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
565Logano GB1*5, Logamatic MC10boiler72syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
566Logano GB1*5, Logamatic MC10boiler72boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
567Logano GB1*5, Logamatic MC10boiler72headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
568Logano GB1*5, Logamatic MC10boiler72exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
569Logano GB1*5, Logamatic MC10boiler72burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
570Logano GB1*5, Logamatic MC10boiler72burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
571Logano GB1*5, Logamatic MC10boiler72flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
572Logano GB1*5, Logamatic MC10boiler72fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
573Logano GB1*5, Logamatic MC10boiler72ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
574Logano GB1*5, Logamatic MC10boiler72oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
575Logano GB1*5, Logamatic MC10boiler72burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
576Logano GB1*5, Logamatic MC10boiler72burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
577Logano GB1*5, Logamatic MC10boiler72burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
578Logano GB1*5, Logamatic MC10boiler72absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
579Logano GB1*5, Logamatic MC10boiler72heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
580Logano GB1*5, Logamatic MC10boiler72boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
581Logano GB1*5, Logamatic MC10boiler72boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
582Logano GB1*5, Logamatic MC10boiler72boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
583Logano GB1*5, Logamatic MC10boiler72boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
584Logano GB1*5, Logamatic MC10boiler72curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
585Logano GB1*5, Logamatic MC10boiler72curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
586Logano GB1*5, Logamatic MC10boiler72curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
587Logano GB1*5, Logamatic MC10boiler72summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
588Logano GB1*5, Logamatic MC10boiler72nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
589Logano GB1*5, Logamatic MC10boiler72nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
590Logano GB1*5, Logamatic MC10boiler72heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
591Logano GB1*5, Logamatic MC10boiler72heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
592Logano GB1*5, Logamatic MC10boiler72heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
593Logano GB1*5, Logamatic MC10boiler72pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
594Logano GB1*5, Logamatic MC10boiler72pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
595Logano GB1*5, Logamatic MC10boiler72pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
596Logano GB1*5, Logamatic MC10boiler72pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
597Logano GB1*5, Logamatic MC10boiler72pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
598Logano GB1*5, Logamatic MC10boiler72pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
599Logano GB1*5, Logamatic MC10boiler72selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
600Logano GB1*5, Logamatic MC10boiler72curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
601Logano GB1*5, Logamatic MC10boiler72burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
602Logano GB1*5, Logamatic MC10boiler72burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
603Logano GB1*5, Logamatic MC10boiler72burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
604Logano GB1*5, Logamatic MC10boiler72heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
605Logano GB1*5, Logamatic MC10boiler72heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
606Logano GB1*5, Logamatic MC10boiler72ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
607Logano GB1*5, Logamatic MC10boiler72lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
608Logano GB1*5, Logamatic MC10boiler72servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
609Logano GB1*5, Logamatic MC10boiler72servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
610Logano GB1*5, Logamatic MC10boiler72maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
611Logano GB1*5, Logamatic MC10boiler72maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
612Logano GB1*5, Logamatic MC10boiler72maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
613Logano GB1*5, Logamatic MC10boiler72maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
614Logano GB1*5, Logamatic MC10boiler72emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
615Logano GB1*5, Logamatic MC10boiler72emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
616Logano GB1*5, Logamatic MC10boiler72pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
617Logano GB1*5, Logamatic MC10boiler72pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
618Logano GB1*5, Logamatic MC10boiler72pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
619Logano GB1*5, Logamatic MC10boiler72pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
620Logano GB1*5, Logamatic MC10boiler72meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
621Logano GB1*5, Logamatic MC10boiler72dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
622Logano GB1*5, Logamatic MC10boiler72gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
623Logano GB1*5, Logamatic MC10boiler72dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
624Logano GB1*5, Logamatic MC10boiler72nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
625Logano GB1*5, Logamatic MC10boiler72dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
626Logano GB1*5, Logamatic MC10boiler72dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
627Logano GB1*5, Logamatic MC10boiler72dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
628Logano GB1*5, Logamatic MC10boiler72dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
629Logano GB1*5, Logamatic MC10boiler72dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
630Logano GB1*5, Logamatic MC10boiler72dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
631Logano GB1*5, Logamatic MC10boiler72dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
632Logano GB1*5, Logamatic MC10boiler72dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
633Logano GB1*5, Logamatic MC10boiler72dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
634Logano GB1*5, Logamatic MC10boiler72dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
635Logano GB1*5, Logamatic MC10boiler72dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
636Logano GB1*5, Logamatic MC10boiler72dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
637Logano GB1*5, Logamatic MC10boiler72dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
638Logano GB1*5, Logamatic MC10boiler72dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
639Logano GB1*5, Logamatic MC10boiler72dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
640Logano GB1*5, Logamatic MC10boiler72dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
641Logano GB1*5, Logamatic MC10boiler72dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
642Logano GB1*5, Logamatic MC10boiler72dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
643Logano GB1*5, Logamatic MC10boiler72dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
644Logano GB1*5, Logamatic MC10boiler72dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
645Logano GB1*5, Logamatic MC10boiler72dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
646Logano GB1*5, Logamatic MC10boiler72dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
647Logano GB1*5, Logamatic MC10boiler72dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
648Logano GB1*5, Logamatic MC10boiler72dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
649Logano GB1*5, Logamatic MC10boiler72dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
650Logano GB1*5, Logamatic MC10boiler72dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
651Logano GB1*5, Logamatic MC10boiler72dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
652Logano GB1*5, Logamatic MC10boiler72dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
653Logano GB1*5, Logamatic MC10boiler72dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
654Logano GB1*5, Logamatic MC10boiler72dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
655Logano GB1*5, Logamatic MC10boiler72dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
656Logano GB1*5, Logamatic MC10boiler72dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
657Logano GB1*5, Logamatic MC10boiler72dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
658Logano GB1*5, Logamatic MC10boiler72dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
659Logano GB1*5, Logamatic MC10boiler72dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
660Logano GB1*5, Logamatic MC10boiler72dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
661Logano GB1*5, Logamatic MC10boiler72dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
662Logano GB1*5, Logamatic MC10boiler72dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
663Logano GB1*5, Logamatic MC10boiler72dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
664Logano GB1*5, Logamatic MC10boiler72dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
665Logano GB1*5, Logamatic MC10boiler72dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
666Logano GB1*5, Logamatic MC10boiler72nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
667Logano GB1*5, Logamatic MC10boiler72nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
668Logano GB1*5, Logamatic MC10boiler72nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
669Logano GB1*5, Logamatic MC10boiler72dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
670Cascade CM10boiler81resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
671Cascade CM10boiler81heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
672Cascade CM10boiler81heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
673Cascade CM10boiler81tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
674Cascade CM10boiler81selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
675Cascade CM10boiler81heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
676Cascade CM10boiler81outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
677Cascade CM10boiler81curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
678Cascade CM10boiler81rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
679Cascade CM10boiler81switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
680Cascade CM10boiler81syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
681Cascade CM10boiler81boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
682Cascade CM10boiler81headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
683Cascade CM10boiler81exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
684Cascade CM10boiler81burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
685Cascade CM10boiler81burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
686Cascade CM10boiler81flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
687Cascade CM10boiler81fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
688Cascade CM10boiler81ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
689Cascade CM10boiler81oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
690Cascade CM10boiler81burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
691Cascade CM10boiler81burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
692Cascade CM10boiler81burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
693Cascade CM10boiler81absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
694Cascade CM10boiler81heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
695Cascade CM10boiler81boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
696Cascade CM10boiler81boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
697Cascade CM10boiler81boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
698Cascade CM10boiler81boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
699Cascade CM10boiler81curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
700Cascade CM10boiler81curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
701Cascade CM10boiler81curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
702Cascade CM10boiler81summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
703Cascade CM10boiler81nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
704Cascade CM10boiler81nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
705Cascade CM10boiler81heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
706Cascade CM10boiler81heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
707Cascade CM10boiler81heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
708Cascade CM10boiler81pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
709Cascade CM10boiler81pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
710Cascade CM10boiler81pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
711Cascade CM10boiler81pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
712Cascade CM10boiler81pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
713Cascade CM10boiler81pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
714Cascade CM10boiler81selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
715Cascade CM10boiler81curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
716Cascade CM10boiler81burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
717Cascade CM10boiler81burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
718Cascade CM10boiler81burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
719Cascade CM10boiler81heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
720Cascade CM10boiler81heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
721Cascade CM10boiler81ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
722Cascade CM10boiler81lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
723Cascade CM10boiler81servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
724Cascade CM10boiler81servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
725Cascade CM10boiler81maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
726Cascade CM10boiler81maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
727Cascade CM10boiler81maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
728Cascade CM10boiler81maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
729Cascade CM10boiler81emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
730Cascade CM10boiler81emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
731Cascade CM10boiler81pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
732Cascade CM10boiler81pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
733Cascade CM10boiler81pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
734Cascade CM10boiler81pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
735Cascade CM10boiler81meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
736Cascade CM10boiler81dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
737Cascade CM10boiler81gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
738Cascade CM10boiler81dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
739Cascade CM10boiler81nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
740Cascade CM10boiler81dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
741Cascade CM10boiler81dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
742Cascade CM10boiler81dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
743Cascade CM10boiler81dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
744Cascade CM10boiler81dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
745Cascade CM10boiler81dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
746Cascade CM10boiler81dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
747Cascade CM10boiler81dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
748Cascade CM10boiler81dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
749Cascade CM10boiler81dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
750Cascade CM10boiler81dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
751Cascade CM10boiler81dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
752Cascade CM10boiler81dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
753Cascade CM10boiler81dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
754Cascade CM10boiler81dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
755Cascade CM10boiler81dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
756Cascade CM10boiler81dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
757Cascade CM10boiler81dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
758Cascade CM10boiler81dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
759Cascade CM10boiler81dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
760Cascade CM10boiler81dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
761Cascade CM10boiler81dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
762Cascade CM10boiler81dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
763Cascade CM10boiler81dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
764Cascade CM10boiler81dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
765Cascade CM10boiler81dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
766Cascade CM10boiler81dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
767Cascade CM10boiler81dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
768Cascade CM10boiler81dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
769Cascade CM10boiler81dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
770Cascade CM10boiler81dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
771Cascade CM10boiler81dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
772Cascade CM10boiler81dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
773Cascade CM10boiler81dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
774Cascade CM10boiler81dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
775Cascade CM10boiler81dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
776Cascade CM10boiler81dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
777Cascade CM10boiler81dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
778Cascade CM10boiler81dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
779Cascade CM10boiler81dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
780Cascade CM10boiler81dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
781Cascade CM10boiler81nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
782Cascade CM10boiler81nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
783Cascade CM10boiler81nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
784Cascade CM10boiler81dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
785Logamax Plus GB022boiler84resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
786Logamax Plus GB022boiler84heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
787Logamax Plus GB022boiler84heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
788Logamax Plus GB022boiler84tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
789Logamax Plus GB022boiler84selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
790Logamax Plus GB022boiler84heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
791Logamax Plus GB022boiler84outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
792Logamax Plus GB022boiler84curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
793Logamax Plus GB022boiler84rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
794Logamax Plus GB022boiler84switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
795Logamax Plus GB022boiler84syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
796Logamax Plus GB022boiler84boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
797Logamax Plus GB022boiler84headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
798Logamax Plus GB022boiler84exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
799Logamax Plus GB022boiler84burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
800Logamax Plus GB022boiler84burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
801Logamax Plus GB022boiler84flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
802Logamax Plus GB022boiler84fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
803Logamax Plus GB022boiler84ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
804Logamax Plus GB022boiler84oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
805Logamax Plus GB022boiler84burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
806Logamax Plus GB022boiler84burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
807Logamax Plus GB022boiler84burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
808Logamax Plus GB022boiler84absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
809Logamax Plus GB022boiler84heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
810Logamax Plus GB022boiler84boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
811Logamax Plus GB022boiler84boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
812Logamax Plus GB022boiler84boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
813Logamax Plus GB022boiler84boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
814Logamax Plus GB022boiler84curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
815Logamax Plus GB022boiler84curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
816Logamax Plus GB022boiler84curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
817Logamax Plus GB022boiler84summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
818Logamax Plus GB022boiler84nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
819Logamax Plus GB022boiler84nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
820Logamax Plus GB022boiler84heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
821Logamax Plus GB022boiler84heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
822Logamax Plus GB022boiler84heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
823Logamax Plus GB022boiler84pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
824Logamax Plus GB022boiler84pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
825Logamax Plus GB022boiler84pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
826Logamax Plus GB022boiler84pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
827Logamax Plus GB022boiler84pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
828Logamax Plus GB022boiler84pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
829Logamax Plus GB022boiler84selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
830Logamax Plus GB022boiler84curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
831Logamax Plus GB022boiler84burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
832Logamax Plus GB022boiler84burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
833Logamax Plus GB022boiler84burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
834Logamax Plus GB022boiler84heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
835Logamax Plus GB022boiler84heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
836Logamax Plus GB022boiler84ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
837Logamax Plus GB022boiler84lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
838Logamax Plus GB022boiler84servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
839Logamax Plus GB022boiler84servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
840Logamax Plus GB022boiler84maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
841Logamax Plus GB022boiler84maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
842Logamax Plus GB022boiler84maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
843Logamax Plus GB022boiler84maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
844Logamax Plus GB022boiler84emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
845Logamax Plus GB022boiler84emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
846Logamax Plus GB022boiler84pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
847Logamax Plus GB022boiler84pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
848Logamax Plus GB022boiler84pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
849Logamax Plus GB022boiler84pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
850Logamax Plus GB022boiler84meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
851Logamax Plus GB022boiler84dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
852Logamax Plus GB022boiler84gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
853Logamax Plus GB022boiler84dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
854Logamax Plus GB022boiler84nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
855Logamax Plus GB022boiler84dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
856Logamax Plus GB022boiler84dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
857Logamax Plus GB022boiler84dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
858Logamax Plus GB022boiler84dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
859Logamax Plus GB022boiler84dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
860Logamax Plus GB022boiler84dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
861Logamax Plus GB022boiler84dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
862Logamax Plus GB022boiler84dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
863Logamax Plus GB022boiler84dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
864Logamax Plus GB022boiler84dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
865Logamax Plus GB022boiler84dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
866Logamax Plus GB022boiler84dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
867Logamax Plus GB022boiler84dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
868Logamax Plus GB022boiler84dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
869Logamax Plus GB022boiler84dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
870Logamax Plus GB022boiler84dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
871Logamax Plus GB022boiler84dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
872Logamax Plus GB022boiler84dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
873Logamax Plus GB022boiler84dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
874Logamax Plus GB022boiler84dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
875Logamax Plus GB022boiler84dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
876Logamax Plus GB022boiler84dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
877Logamax Plus GB022boiler84dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
878Logamax Plus GB022boiler84dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
879Logamax Plus GB022boiler84dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
880Logamax Plus GB022boiler84dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
881Logamax Plus GB022boiler84dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
882Logamax Plus GB022boiler84dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
883Logamax Plus GB022boiler84dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
884Logamax Plus GB022boiler84dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
885Logamax Plus GB022boiler84dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
886Logamax Plus GB022boiler84dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
887Logamax Plus GB022boiler84dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
888Logamax Plus GB022boiler84dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
889Logamax Plus GB022boiler84dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
890Logamax Plus GB022boiler84dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
891Logamax Plus GB022boiler84dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
892Logamax Plus GB022boiler84dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
893Logamax Plus GB022boiler84dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
894Logamax Plus GB022boiler84dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
895Logamax Plus GB022boiler84dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
896Logamax Plus GB022boiler84nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
897Logamax Plus GB022boiler84nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
898Logamax Plus GB022boiler84nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
899Logamax Plus GB022boiler84dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
900Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
901Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
902Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
903Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
904Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
905Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
906Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
907Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
908Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
909Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
910Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
911Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
912Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
913Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
914Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
915Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
916Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
917Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
918Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
919Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
920Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
921Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
922Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
923Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
924Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
925Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
926Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
927Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
928Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
929Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
930Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
931Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
932Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
933Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
934Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
935Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
936Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
937Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
938Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
939Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
940Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
941Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
942Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
943Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
944Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
945Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
946Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
947Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
948Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
949Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
950Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
951Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
952Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
953Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
954Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
955Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
956Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
957Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
958Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
959Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
960Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
961Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
962Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
963Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
964Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
965Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
966Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
967Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
968Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
969Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
970Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
971Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
972Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
973Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
974Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
975Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
976Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
977Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
978Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
979Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
980Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
981Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
982Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
983Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
984Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
985Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
986Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
987Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
988Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
989Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
990Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
991Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
992Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
993Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
994Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
995Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
996Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
997Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
998Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
999Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1000Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1001Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1002Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1003Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1004Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1005Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1006Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
1007Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1008Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1009Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1010Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1011Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1012Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1013Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1014Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3boiler95dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1015Topline, GB162boiler115resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1016Topline, GB162boiler115heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1017Topline, GB162boiler115heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1018Topline, GB162boiler115tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1019Topline, GB162boiler115selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1020Topline, GB162boiler115heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1021Topline, GB162boiler115outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1022Topline, GB162boiler115curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1023Topline, GB162boiler115rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1024Topline, GB162boiler115switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1025Topline, GB162boiler115syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1026Topline, GB162boiler115boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1027Topline, GB162boiler115headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1028Topline, GB162boiler115exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1029Topline, GB162boiler115burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1030Topline, GB162boiler115burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1031Topline, GB162boiler115flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1032Topline, GB162boiler115fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1033Topline, GB162boiler115ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1034Topline, GB162boiler115oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1035Topline, GB162boiler115burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1036Topline, GB162boiler115burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1037Topline, GB162boiler115burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1038Topline, GB162boiler115absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1039Topline, GB162boiler115heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1040Topline, GB162boiler115boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1041Topline, GB162boiler115boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1042Topline, GB162boiler115boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1043Topline, GB162boiler115boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1044Topline, GB162boiler115curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1045Topline, GB162boiler115curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1046Topline, GB162boiler115curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1047Topline, GB162boiler115summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1048Topline, GB162boiler115nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1049Topline, GB162boiler115nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1050Topline, GB162boiler115heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1051Topline, GB162boiler115heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1052Topline, GB162boiler115heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1053Topline, GB162boiler115pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1054Topline, GB162boiler115pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1055Topline, GB162boiler115pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1056Topline, GB162boiler115pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1057Topline, GB162boiler115pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1058Topline, GB162boiler115pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1059Topline, GB162boiler115selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1060Topline, GB162boiler115curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1061Topline, GB162boiler115burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1062Topline, GB162boiler115burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1063Topline, GB162boiler115burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1064Topline, GB162boiler115heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1065Topline, GB162boiler115heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1066Topline, GB162boiler115ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1067Topline, GB162boiler115lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1068Topline, GB162boiler115servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1069Topline, GB162boiler115servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1070Topline, GB162boiler115maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1071Topline, GB162boiler115maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1072Topline, GB162boiler115maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1073Topline, GB162boiler115maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1074Topline, GB162boiler115emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1075Topline, GB162boiler115emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1076Topline, GB162boiler115pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1077Topline, GB162boiler115pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1078Topline, GB162boiler115pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1079Topline, GB162boiler115pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1080Topline, GB162boiler115meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1081Topline, GB162boiler115dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1082Topline, GB162boiler115gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1083Topline, GB162boiler115dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1084Topline, GB162boiler115nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1085Topline, GB162boiler115dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1086Topline, GB162boiler115dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1087Topline, GB162boiler115dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1088Topline, GB162boiler115dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1089Topline, GB162boiler115dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1090Topline, GB162boiler115dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1091Topline, GB162boiler115dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1092Topline, GB162boiler115dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1093Topline, GB162boiler115dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1094Topline, GB162boiler115dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1095Topline, GB162boiler115dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1096Topline, GB162boiler115dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1097Topline, GB162boiler115dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1098Topline, GB162boiler115dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1099Topline, GB162boiler115dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1100Topline, GB162boiler115dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1101Topline, GB162boiler115dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1102Topline, GB162boiler115dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1103Topline, GB162boiler115dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1104Topline, GB162boiler115dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1105Topline, GB162boiler115dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1106Topline, GB162boiler115dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1107Topline, GB162boiler115dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1108Topline, GB162boiler115dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1109Topline, GB162boiler115dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1110Topline, GB162boiler115dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1111Topline, GB162boiler115dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1112Topline, GB162boiler115dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1113Topline, GB162boiler115dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1114Topline, GB162boiler115dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1115Topline, GB162boiler115dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1116Topline, GB162boiler115dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1117Topline, GB162boiler115dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1118Topline, GB162boiler115dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1119Topline, GB162boiler115dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1120Topline, GB162boiler115dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1121Topline, GB162boiler115dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
1122Topline, GB162boiler115dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1123Topline, GB162boiler115dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1124Topline, GB162boiler115dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1125Topline, GB162boiler115dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1126Topline, GB162boiler115nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1127Topline, GB162boiler115nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1128Topline, GB162boiler115nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1129Topline, GB162boiler115dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1130Cascade MCM10boiler121resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1131Cascade MCM10boiler121heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1132Cascade MCM10boiler121heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1133Cascade MCM10boiler121tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1134Cascade MCM10boiler121selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1135Cascade MCM10boiler121heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1136Cascade MCM10boiler121outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1137Cascade MCM10boiler121curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1138Cascade MCM10boiler121rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1139Cascade MCM10boiler121switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1140Cascade MCM10boiler121syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1141Cascade MCM10boiler121boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1142Cascade MCM10boiler121headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1143Cascade MCM10boiler121exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1144Cascade MCM10boiler121burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1145Cascade MCM10boiler121burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1146Cascade MCM10boiler121flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1147Cascade MCM10boiler121fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1148Cascade MCM10boiler121ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1149Cascade MCM10boiler121oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1150Cascade MCM10boiler121burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1151Cascade MCM10boiler121burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1152Cascade MCM10boiler121burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1153Cascade MCM10boiler121absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1154Cascade MCM10boiler121heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1155Cascade MCM10boiler121boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1156Cascade MCM10boiler121boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1157Cascade MCM10boiler121boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1158Cascade MCM10boiler121boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1159Cascade MCM10boiler121curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1160Cascade MCM10boiler121curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1161Cascade MCM10boiler121curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1162Cascade MCM10boiler121summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1163Cascade MCM10boiler121nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1164Cascade MCM10boiler121nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1165Cascade MCM10boiler121heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1166Cascade MCM10boiler121heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1167Cascade MCM10boiler121heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1168Cascade MCM10boiler121pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1169Cascade MCM10boiler121pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1170Cascade MCM10boiler121pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1171Cascade MCM10boiler121pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1172Cascade MCM10boiler121pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1173Cascade MCM10boiler121pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1174Cascade MCM10boiler121selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1175Cascade MCM10boiler121curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1176Cascade MCM10boiler121burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1177Cascade MCM10boiler121burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1178Cascade MCM10boiler121burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1179Cascade MCM10boiler121heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1180Cascade MCM10boiler121heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1181Cascade MCM10boiler121ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1182Cascade MCM10boiler121lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1183Cascade MCM10boiler121servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1184Cascade MCM10boiler121servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1185Cascade MCM10boiler121maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1186Cascade MCM10boiler121maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1187Cascade MCM10boiler121maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1188Cascade MCM10boiler121maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1189Cascade MCM10boiler121emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1190Cascade MCM10boiler121emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1191Cascade MCM10boiler121pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1192Cascade MCM10boiler121pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1193Cascade MCM10boiler121pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1194Cascade MCM10boiler121pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1195Cascade MCM10boiler121meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1196Cascade MCM10boiler121dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1197Cascade MCM10boiler121gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1198Cascade MCM10boiler121dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1199Cascade MCM10boiler121nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1200Cascade MCM10boiler121dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1201Cascade MCM10boiler121dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1202Cascade MCM10boiler121dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1203Cascade MCM10boiler121dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1204Cascade MCM10boiler121dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1205Cascade MCM10boiler121dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1206Cascade MCM10boiler121dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1207Cascade MCM10boiler121dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1208Cascade MCM10boiler121dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1209Cascade MCM10boiler121dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1210Cascade MCM10boiler121dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1211Cascade MCM10boiler121dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1212Cascade MCM10boiler121dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1213Cascade MCM10boiler121dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1214Cascade MCM10boiler121dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1215Cascade MCM10boiler121dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1216Cascade MCM10boiler121dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1217Cascade MCM10boiler121dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1218Cascade MCM10boiler121dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1219Cascade MCM10boiler121dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1220Cascade MCM10boiler121dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1221Cascade MCM10boiler121dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1222Cascade MCM10boiler121dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1223Cascade MCM10boiler121dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1224Cascade MCM10boiler121dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1225Cascade MCM10boiler121dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1226Cascade MCM10boiler121dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1227Cascade MCM10boiler121dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1228Cascade MCM10boiler121dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1229Cascade MCM10boiler121dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1230Cascade MCM10boiler121dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1231Cascade MCM10boiler121dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1232Cascade MCM10boiler121dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1233Cascade MCM10boiler121dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1234Cascade MCM10boiler121dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1235Cascade MCM10boiler121dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1236Cascade MCM10boiler121dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
1237Cascade MCM10boiler121dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1238Cascade MCM10boiler121dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1239Cascade MCM10boiler121dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1240Cascade MCM10boiler121dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1241Cascade MCM10boiler121nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1242Cascade MCM10boiler121nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1243Cascade MCM10boiler121nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1244Cascade MCM10boiler121dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1245Prolineboiler122resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1246Prolineboiler122heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1247Prolineboiler122heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1248Prolineboiler122tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1249Prolineboiler122selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1250Prolineboiler122heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1251Prolineboiler122outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1252Prolineboiler122curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1253Prolineboiler122rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1254Prolineboiler122switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1255Prolineboiler122syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1256Prolineboiler122boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1257Prolineboiler122headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1258Prolineboiler122exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1259Prolineboiler122burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1260Prolineboiler122burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1261Prolineboiler122flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1262Prolineboiler122fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1263Prolineboiler122ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1264Prolineboiler122oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1265Prolineboiler122burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1266Prolineboiler122burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1267Prolineboiler122burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1268Prolineboiler122absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1269Prolineboiler122heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1270Prolineboiler122boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1271Prolineboiler122boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1272Prolineboiler122boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1273Prolineboiler122boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1274Prolineboiler122curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1275Prolineboiler122curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1276Prolineboiler122curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1277Prolineboiler122summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1278Prolineboiler122nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1279Prolineboiler122nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1280Prolineboiler122heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1281Prolineboiler122heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1282Prolineboiler122heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1283Prolineboiler122pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1284Prolineboiler122pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1285Prolineboiler122pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1286Prolineboiler122pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1287Prolineboiler122pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1288Prolineboiler122pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1289Prolineboiler122selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1290Prolineboiler122curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1291Prolineboiler122burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1292Prolineboiler122burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1293Prolineboiler122burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1294Prolineboiler122heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1295Prolineboiler122heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1296Prolineboiler122ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1297Prolineboiler122lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1298Prolineboiler122servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1299Prolineboiler122servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1300Prolineboiler122maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1301Prolineboiler122maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1302Prolineboiler122maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1303Prolineboiler122maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1304Prolineboiler122emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1305Prolineboiler122emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1306Prolineboiler122pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1307Prolineboiler122pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1308Prolineboiler122pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1309Prolineboiler122pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1310Prolineboiler122meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1311Prolineboiler122dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1312Prolineboiler122gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1313Prolineboiler122dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1314Prolineboiler122nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1315Prolineboiler122dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1316Prolineboiler122dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1317Prolineboiler122dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1318Prolineboiler122dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1319Prolineboiler122dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1320Prolineboiler122dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1321Prolineboiler122dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1322Prolineboiler122dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1323Prolineboiler122dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1324Prolineboiler122dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1325Prolineboiler122dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1326Prolineboiler122dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1327Prolineboiler122dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1328Prolineboiler122dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1329Prolineboiler122dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1330Prolineboiler122dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1331Prolineboiler122dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1332Prolineboiler122dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1333Prolineboiler122dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1334Prolineboiler122dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1335Prolineboiler122dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1336Prolineboiler122dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1337Prolineboiler122dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1338Prolineboiler122dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1339Prolineboiler122dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1340Prolineboiler122dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1341Prolineboiler122dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1342Prolineboiler122dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1343Prolineboiler122dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1344Prolineboiler122dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1345Prolineboiler122dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1346Prolineboiler122dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1347Prolineboiler122dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1348Prolineboiler122dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1349Prolineboiler122dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1350Prolineboiler122dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1351Prolineboiler122dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
1352Prolineboiler122dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1353Prolineboiler122dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1354Prolineboiler122dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1355Prolineboiler122dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1356Prolineboiler122nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1357Prolineboiler122nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1358Prolineboiler122nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1359Prolineboiler122dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1360GB*72, Trendline, Cerapur, Greenstar Siboiler123resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1361GB*72, Trendline, Cerapur, Greenstar Siboiler123heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1362GB*72, Trendline, Cerapur, Greenstar Siboiler123heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1363GB*72, Trendline, Cerapur, Greenstar Siboiler123tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1364GB*72, Trendline, Cerapur, Greenstar Siboiler123selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1365GB*72, Trendline, Cerapur, Greenstar Siboiler123heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1366GB*72, Trendline, Cerapur, Greenstar Siboiler123outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1367GB*72, Trendline, Cerapur, Greenstar Siboiler123curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1368GB*72, Trendline, Cerapur, Greenstar Siboiler123rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1369GB*72, Trendline, Cerapur, Greenstar Siboiler123switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1370GB*72, Trendline, Cerapur, Greenstar Siboiler123syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1371GB*72, Trendline, Cerapur, Greenstar Siboiler123boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1372GB*72, Trendline, Cerapur, Greenstar Siboiler123headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1373GB*72, Trendline, Cerapur, Greenstar Siboiler123exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1374GB*72, Trendline, Cerapur, Greenstar Siboiler123burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1375GB*72, Trendline, Cerapur, Greenstar Siboiler123burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1376GB*72, Trendline, Cerapur, Greenstar Siboiler123flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1377GB*72, Trendline, Cerapur, Greenstar Siboiler123fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1378GB*72, Trendline, Cerapur, Greenstar Siboiler123ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1379GB*72, Trendline, Cerapur, Greenstar Siboiler123oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1380GB*72, Trendline, Cerapur, Greenstar Siboiler123burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1381GB*72, Trendline, Cerapur, Greenstar Siboiler123burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1382GB*72, Trendline, Cerapur, Greenstar Siboiler123burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1383GB*72, Trendline, Cerapur, Greenstar Siboiler123absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1384GB*72, Trendline, Cerapur, Greenstar Siboiler123heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1385GB*72, Trendline, Cerapur, Greenstar Siboiler123boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1386GB*72, Trendline, Cerapur, Greenstar Siboiler123boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1387GB*72, Trendline, Cerapur, Greenstar Siboiler123boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1388GB*72, Trendline, Cerapur, Greenstar Siboiler123boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1389GB*72, Trendline, Cerapur, Greenstar Siboiler123curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1390GB*72, Trendline, Cerapur, Greenstar Siboiler123curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1391GB*72, Trendline, Cerapur, Greenstar Siboiler123curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1392GB*72, Trendline, Cerapur, Greenstar Siboiler123summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1393GB*72, Trendline, Cerapur, Greenstar Siboiler123nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1394GB*72, Trendline, Cerapur, Greenstar Siboiler123nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1395GB*72, Trendline, Cerapur, Greenstar Siboiler123heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1396GB*72, Trendline, Cerapur, Greenstar Siboiler123heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1397GB*72, Trendline, Cerapur, Greenstar Siboiler123heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1398GB*72, Trendline, Cerapur, Greenstar Siboiler123pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1399GB*72, Trendline, Cerapur, Greenstar Siboiler123pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1400GB*72, Trendline, Cerapur, Greenstar Siboiler123pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1401GB*72, Trendline, Cerapur, Greenstar Siboiler123pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1402GB*72, Trendline, Cerapur, Greenstar Siboiler123pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1403GB*72, Trendline, Cerapur, Greenstar Siboiler123pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1404GB*72, Trendline, Cerapur, Greenstar Siboiler123selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1405GB*72, Trendline, Cerapur, Greenstar Siboiler123curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1406GB*72, Trendline, Cerapur, Greenstar Siboiler123burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1407GB*72, Trendline, Cerapur, Greenstar Siboiler123burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1408GB*72, Trendline, Cerapur, Greenstar Siboiler123burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1409GB*72, Trendline, Cerapur, Greenstar Siboiler123heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1410GB*72, Trendline, Cerapur, Greenstar Siboiler123heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1411GB*72, Trendline, Cerapur, Greenstar Siboiler123ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1412GB*72, Trendline, Cerapur, Greenstar Siboiler123lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1413GB*72, Trendline, Cerapur, Greenstar Siboiler123servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1414GB*72, Trendline, Cerapur, Greenstar Siboiler123servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1415GB*72, Trendline, Cerapur, Greenstar Siboiler123maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1416GB*72, Trendline, Cerapur, Greenstar Siboiler123maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1417GB*72, Trendline, Cerapur, Greenstar Siboiler123maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1418GB*72, Trendline, Cerapur, Greenstar Siboiler123maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1419GB*72, Trendline, Cerapur, Greenstar Siboiler123emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1420GB*72, Trendline, Cerapur, Greenstar Siboiler123emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1421GB*72, Trendline, Cerapur, Greenstar Siboiler123pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1422GB*72, Trendline, Cerapur, Greenstar Siboiler123pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1423GB*72, Trendline, Cerapur, Greenstar Siboiler123pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1424GB*72, Trendline, Cerapur, Greenstar Siboiler123pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1425GB*72, Trendline, Cerapur, Greenstar Siboiler123meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1426GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1427GB*72, Trendline, Cerapur, Greenstar Siboiler123gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1428GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1429GB*72, Trendline, Cerapur, Greenstar Siboiler123nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1430GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1431GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1432GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1433GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1434GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1435GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1436GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1437GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1438GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1439GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1440GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1441GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1442GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1443GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1444GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1445GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1446GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1447GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1448GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1449GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1450GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1451GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1452GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1453GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1454GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1455GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1456GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1457GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1458GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1459GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1460GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1461GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1462GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1463GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1464GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1465GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1466GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
1467GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1468GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1469GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1470GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1471GB*72, Trendline, Cerapur, Greenstar Siboiler123nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1472GB*72, Trendline, Cerapur, Greenstar Siboiler123nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1473GB*72, Trendline, Cerapur, Greenstar Siboiler123nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1474GB*72, Trendline, Cerapur, Greenstar Siboiler123dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1475GB212boiler131resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1476GB212boiler131heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1477GB212boiler131heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1478GB212boiler131tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1479GB212boiler131selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1480GB212boiler131heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1481GB212boiler131outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1482GB212boiler131curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1483GB212boiler131rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1484GB212boiler131switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1485GB212boiler131syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1486GB212boiler131boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1487GB212boiler131headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1488GB212boiler131exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1489GB212boiler131burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1490GB212boiler131burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1491GB212boiler131flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1492GB212boiler131fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1493GB212boiler131ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1494GB212boiler131oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1495GB212boiler131burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1496GB212boiler131burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1497GB212boiler131burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1498GB212boiler131absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1499GB212boiler131heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1500GB212boiler131boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1501GB212boiler131boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1502GB212boiler131boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1503GB212boiler131boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1504GB212boiler131curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1505GB212boiler131curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1506GB212boiler131curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1507GB212boiler131summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1508GB212boiler131nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1509GB212boiler131nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1510GB212boiler131heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1511GB212boiler131heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1512GB212boiler131heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1513GB212boiler131pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1514GB212boiler131pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1515GB212boiler131pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1516GB212boiler131pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1517GB212boiler131pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1518GB212boiler131pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1519GB212boiler131selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1520GB212boiler131curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1521GB212boiler131burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1522GB212boiler131burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1523GB212boiler131burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1524GB212boiler131heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1525GB212boiler131heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1526GB212boiler131ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1527GB212boiler131lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1528GB212boiler131servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1529GB212boiler131servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1530GB212boiler131maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1531GB212boiler131maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1532GB212boiler131maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1533GB212boiler131maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1534GB212boiler131emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1535GB212boiler131emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1536GB212boiler131pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1537GB212boiler131pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1538GB212boiler131pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1539GB212boiler131pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1540GB212boiler131meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1541GB212boiler131dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1542GB212boiler131gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1543GB212boiler131dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1544GB212boiler131nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1545GB212boiler131dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1546GB212boiler131dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1547GB212boiler131dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1548GB212boiler131dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1549GB212boiler131dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1550GB212boiler131dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1551GB212boiler131dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1552GB212boiler131dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1553GB212boiler131dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1554GB212boiler131dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1555GB212boiler131dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1556GB212boiler131dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1557GB212boiler131dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1558GB212boiler131dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1559GB212boiler131dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1560GB212boiler131dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1561GB212boiler131dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1562GB212boiler131dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1563GB212boiler131dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1564GB212boiler131dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1565GB212boiler131dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1566GB212boiler131dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1567GB212boiler131dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1568GB212boiler131dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1569GB212boiler131dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1570GB212boiler131dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1571GB212boiler131dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1572GB212boiler131dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1573GB212boiler131dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1574GB212boiler131dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1575GB212boiler131dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1576GB212boiler131dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1577GB212boiler131dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1578GB212boiler131dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1579GB212boiler131dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1580GB212boiler131dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1581GB212boiler131dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
1582GB212boiler131dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1583GB212boiler131dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1584GB212boiler131dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1585GB212boiler131dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1586GB212boiler131nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1587GB212boiler131nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1588GB212boiler131nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1589GB212boiler131dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1590GC7000Fboiler132resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1591GC7000Fboiler132heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1592GC7000Fboiler132heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1593GC7000Fboiler132tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1594GC7000Fboiler132selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1595GC7000Fboiler132heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1596GC7000Fboiler132outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1597GC7000Fboiler132curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1598GC7000Fboiler132rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1599GC7000Fboiler132switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1600GC7000Fboiler132syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1601GC7000Fboiler132boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1602GC7000Fboiler132headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1603GC7000Fboiler132exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1604GC7000Fboiler132burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1605GC7000Fboiler132burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1606GC7000Fboiler132flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1607GC7000Fboiler132fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1608GC7000Fboiler132ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1609GC7000Fboiler132oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1610GC7000Fboiler132burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1611GC7000Fboiler132burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1612GC7000Fboiler132burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1613GC7000Fboiler132absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1614GC7000Fboiler132heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1615GC7000Fboiler132boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1616GC7000Fboiler132boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1617GC7000Fboiler132boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1618GC7000Fboiler132boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1619GC7000Fboiler132curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1620GC7000Fboiler132curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1621GC7000Fboiler132curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1622GC7000Fboiler132summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1623GC7000Fboiler132nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1624GC7000Fboiler132nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1625GC7000Fboiler132heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1626GC7000Fboiler132heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1627GC7000Fboiler132heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1628GC7000Fboiler132pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1629GC7000Fboiler132pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1630GC7000Fboiler132pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1631GC7000Fboiler132pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1632GC7000Fboiler132pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1633GC7000Fboiler132pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1634GC7000Fboiler132selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1635GC7000Fboiler132curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1636GC7000Fboiler132burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1637GC7000Fboiler132burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1638GC7000Fboiler132burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1639GC7000Fboiler132heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1640GC7000Fboiler132heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1641GC7000Fboiler132ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1642GC7000Fboiler132lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1643GC7000Fboiler132servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1644GC7000Fboiler132servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1645GC7000Fboiler132maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1646GC7000Fboiler132maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1647GC7000Fboiler132maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1648GC7000Fboiler132maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1649GC7000Fboiler132emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1650GC7000Fboiler132emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1651GC7000Fboiler132pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1652GC7000Fboiler132pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1653GC7000Fboiler132pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1654GC7000Fboiler132pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1655GC7000Fboiler132meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1656GC7000Fboiler132dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1657GC7000Fboiler132gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1658GC7000Fboiler132dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1659GC7000Fboiler132nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1660GC7000Fboiler132dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1661GC7000Fboiler132dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1662GC7000Fboiler132dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1663GC7000Fboiler132dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1664GC7000Fboiler132dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1665GC7000Fboiler132dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1666GC7000Fboiler132dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1667GC7000Fboiler132dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1668GC7000Fboiler132dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1669GC7000Fboiler132dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1670GC7000Fboiler132dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1671GC7000Fboiler132dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1672GC7000Fboiler132dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1673GC7000Fboiler132dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1674GC7000Fboiler132dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1675GC7000Fboiler132dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1676GC7000Fboiler132dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1677GC7000Fboiler132dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1678GC7000Fboiler132dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1679GC7000Fboiler132dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1680GC7000Fboiler132dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1681GC7000Fboiler132dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1682GC7000Fboiler132dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1683GC7000Fboiler132dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1684GC7000Fboiler132dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1685GC7000Fboiler132dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1686GC7000Fboiler132dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1687GC7000Fboiler132dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1688GC7000Fboiler132dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1689GC7000Fboiler132dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1690GC7000Fboiler132dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1691GC7000Fboiler132dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1692GC7000Fboiler132dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1693GC7000Fboiler132dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1694GC7000Fboiler132dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1695GC7000Fboiler132dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1696GC7000Fboiler132dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
1697GC7000Fboiler132dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1698GC7000Fboiler132dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1699GC7000Fboiler132dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1700GC7000Fboiler132dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1701GC7000Fboiler132nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1702GC7000Fboiler132nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1703GC7000Fboiler132nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1704GC7000Fboiler132dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1705Logano GB125/KB195i, Logamatic MC110boiler133resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1706Logano GB125/KB195i, Logamatic MC110boiler133heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1707Logano GB125/KB195i, Logamatic MC110boiler133heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1708Logano GB125/KB195i, Logamatic MC110boiler133tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1709Logano GB125/KB195i, Logamatic MC110boiler133selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1710Logano GB125/KB195i, Logamatic MC110boiler133heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1711Logano GB125/KB195i, Logamatic MC110boiler133outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1712Logano GB125/KB195i, Logamatic MC110boiler133curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1713Logano GB125/KB195i, Logamatic MC110boiler133rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1714Logano GB125/KB195i, Logamatic MC110boiler133switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1715Logano GB125/KB195i, Logamatic MC110boiler133syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1716Logano GB125/KB195i, Logamatic MC110boiler133boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1717Logano GB125/KB195i, Logamatic MC110boiler133headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1718Logano GB125/KB195i, Logamatic MC110boiler133exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1719Logano GB125/KB195i, Logamatic MC110boiler133burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1720Logano GB125/KB195i, Logamatic MC110boiler133burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1721Logano GB125/KB195i, Logamatic MC110boiler133flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1722Logano GB125/KB195i, Logamatic MC110boiler133fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1723Logano GB125/KB195i, Logamatic MC110boiler133ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1724Logano GB125/KB195i, Logamatic MC110boiler133oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1725Logano GB125/KB195i, Logamatic MC110boiler133burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1726Logano GB125/KB195i, Logamatic MC110boiler133burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1727Logano GB125/KB195i, Logamatic MC110boiler133burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1728Logano GB125/KB195i, Logamatic MC110boiler133absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1729Logano GB125/KB195i, Logamatic MC110boiler133heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1730Logano GB125/KB195i, Logamatic MC110boiler133boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1731Logano GB125/KB195i, Logamatic MC110boiler133boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1732Logano GB125/KB195i, Logamatic MC110boiler133boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1733Logano GB125/KB195i, Logamatic MC110boiler133boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1734Logano GB125/KB195i, Logamatic MC110boiler133curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1735Logano GB125/KB195i, Logamatic MC110boiler133curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1736Logano GB125/KB195i, Logamatic MC110boiler133curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1737Logano GB125/KB195i, Logamatic MC110boiler133summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1738Logano GB125/KB195i, Logamatic MC110boiler133nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1739Logano GB125/KB195i, Logamatic MC110boiler133nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1740Logano GB125/KB195i, Logamatic MC110boiler133heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1741Logano GB125/KB195i, Logamatic MC110boiler133heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1742Logano GB125/KB195i, Logamatic MC110boiler133heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1743Logano GB125/KB195i, Logamatic MC110boiler133pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1744Logano GB125/KB195i, Logamatic MC110boiler133pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1745Logano GB125/KB195i, Logamatic MC110boiler133pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1746Logano GB125/KB195i, Logamatic MC110boiler133pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1747Logano GB125/KB195i, Logamatic MC110boiler133pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1748Logano GB125/KB195i, Logamatic MC110boiler133pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1749Logano GB125/KB195i, Logamatic MC110boiler133selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1750Logano GB125/KB195i, Logamatic MC110boiler133curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1751Logano GB125/KB195i, Logamatic MC110boiler133burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1752Logano GB125/KB195i, Logamatic MC110boiler133burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1753Logano GB125/KB195i, Logamatic MC110boiler133burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1754Logano GB125/KB195i, Logamatic MC110boiler133heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1755Logano GB125/KB195i, Logamatic MC110boiler133heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1756Logano GB125/KB195i, Logamatic MC110boiler133ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1757Logano GB125/KB195i, Logamatic MC110boiler133lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1758Logano GB125/KB195i, Logamatic MC110boiler133servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1759Logano GB125/KB195i, Logamatic MC110boiler133servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1760Logano GB125/KB195i, Logamatic MC110boiler133maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1761Logano GB125/KB195i, Logamatic MC110boiler133maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1762Logano GB125/KB195i, Logamatic MC110boiler133maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1763Logano GB125/KB195i, Logamatic MC110boiler133maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1764Logano GB125/KB195i, Logamatic MC110boiler133emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1765Logano GB125/KB195i, Logamatic MC110boiler133emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1766Logano GB125/KB195i, Logamatic MC110boiler133pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1767Logano GB125/KB195i, Logamatic MC110boiler133pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1768Logano GB125/KB195i, Logamatic MC110boiler133pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1769Logano GB125/KB195i, Logamatic MC110boiler133pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1770Logano GB125/KB195i, Logamatic MC110boiler133meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1771Logano GB125/KB195i, Logamatic MC110boiler133dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1772Logano GB125/KB195i, Logamatic MC110boiler133gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1773Logano GB125/KB195i, Logamatic MC110boiler133dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1774Logano GB125/KB195i, Logamatic MC110boiler133nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1775Logano GB125/KB195i, Logamatic MC110boiler133dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1776Logano GB125/KB195i, Logamatic MC110boiler133dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1777Logano GB125/KB195i, Logamatic MC110boiler133dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1778Logano GB125/KB195i, Logamatic MC110boiler133dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1779Logano GB125/KB195i, Logamatic MC110boiler133dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1780Logano GB125/KB195i, Logamatic MC110boiler133dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1781Logano GB125/KB195i, Logamatic MC110boiler133dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1782Logano GB125/KB195i, Logamatic MC110boiler133dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1783Logano GB125/KB195i, Logamatic MC110boiler133dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1784Logano GB125/KB195i, Logamatic MC110boiler133dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1785Logano GB125/KB195i, Logamatic MC110boiler133dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1786Logano GB125/KB195i, Logamatic MC110boiler133dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1787Logano GB125/KB195i, Logamatic MC110boiler133dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1788Logano GB125/KB195i, Logamatic MC110boiler133dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1789Logano GB125/KB195i, Logamatic MC110boiler133dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1790Logano GB125/KB195i, Logamatic MC110boiler133dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1791Logano GB125/KB195i, Logamatic MC110boiler133dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1792Logano GB125/KB195i, Logamatic MC110boiler133dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1793Logano GB125/KB195i, Logamatic MC110boiler133dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1794Logano GB125/KB195i, Logamatic MC110boiler133dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1795Logano GB125/KB195i, Logamatic MC110boiler133dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1796Logano GB125/KB195i, Logamatic MC110boiler133dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1797Logano GB125/KB195i, Logamatic MC110boiler133dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1798Logano GB125/KB195i, Logamatic MC110boiler133dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1799Logano GB125/KB195i, Logamatic MC110boiler133dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1800Logano GB125/KB195i, Logamatic MC110boiler133dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1801Logano GB125/KB195i, Logamatic MC110boiler133dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1802Logano GB125/KB195i, Logamatic MC110boiler133dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1803Logano GB125/KB195i, Logamatic MC110boiler133dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1804Logano GB125/KB195i, Logamatic MC110boiler133dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1805Logano GB125/KB195i, Logamatic MC110boiler133dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1806Logano GB125/KB195i, Logamatic MC110boiler133dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1807Logano GB125/KB195i, Logamatic MC110boiler133dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1808Logano GB125/KB195i, Logamatic MC110boiler133dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1809Logano GB125/KB195i, Logamatic MC110boiler133dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1810Logano GB125/KB195i, Logamatic MC110boiler133dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1811Logano GB125/KB195i, Logamatic MC110boiler133dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
1812Logano GB125/KB195i, Logamatic MC110boiler133dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1813Logano GB125/KB195i, Logamatic MC110boiler133dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1814Logano GB125/KB195i, Logamatic MC110boiler133dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1815Logano GB125/KB195i, Logamatic MC110boiler133dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1816Logano GB125/KB195i, Logamatic MC110boiler133nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1817Logano GB125/KB195i, Logamatic MC110boiler133nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1818Logano GB125/KB195i, Logamatic MC110boiler133nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1819Logano GB125/KB195i, Logamatic MC110boiler133dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1820Greenstar 30Ri Compactboiler154resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1821Greenstar 30Ri Compactboiler154heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1822Greenstar 30Ri Compactboiler154heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1823Greenstar 30Ri Compactboiler154tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1824Greenstar 30Ri Compactboiler154selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1825Greenstar 30Ri Compactboiler154heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1826Greenstar 30Ri Compactboiler154outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1827Greenstar 30Ri Compactboiler154curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1828Greenstar 30Ri Compactboiler154rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1829Greenstar 30Ri Compactboiler154switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1830Greenstar 30Ri Compactboiler154syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1831Greenstar 30Ri Compactboiler154boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1832Greenstar 30Ri Compactboiler154headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1833Greenstar 30Ri Compactboiler154exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1834Greenstar 30Ri Compactboiler154burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1835Greenstar 30Ri Compactboiler154burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1836Greenstar 30Ri Compactboiler154flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1837Greenstar 30Ri Compactboiler154fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1838Greenstar 30Ri Compactboiler154ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1839Greenstar 30Ri Compactboiler154oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1840Greenstar 30Ri Compactboiler154burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1841Greenstar 30Ri Compactboiler154burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1842Greenstar 30Ri Compactboiler154burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1843Greenstar 30Ri Compactboiler154absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1844Greenstar 30Ri Compactboiler154heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1845Greenstar 30Ri Compactboiler154boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1846Greenstar 30Ri Compactboiler154boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1847Greenstar 30Ri Compactboiler154boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1848Greenstar 30Ri Compactboiler154boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1849Greenstar 30Ri Compactboiler154curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1850Greenstar 30Ri Compactboiler154curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1851Greenstar 30Ri Compactboiler154curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1852Greenstar 30Ri Compactboiler154summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1853Greenstar 30Ri Compactboiler154nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1854Greenstar 30Ri Compactboiler154nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1855Greenstar 30Ri Compactboiler154heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1856Greenstar 30Ri Compactboiler154heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1857Greenstar 30Ri Compactboiler154heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1858Greenstar 30Ri Compactboiler154pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1859Greenstar 30Ri Compactboiler154pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1860Greenstar 30Ri Compactboiler154pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1861Greenstar 30Ri Compactboiler154pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1862Greenstar 30Ri Compactboiler154pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1863Greenstar 30Ri Compactboiler154pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1864Greenstar 30Ri Compactboiler154selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1865Greenstar 30Ri Compactboiler154curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1866Greenstar 30Ri Compactboiler154burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1867Greenstar 30Ri Compactboiler154burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1868Greenstar 30Ri Compactboiler154burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1869Greenstar 30Ri Compactboiler154heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1870Greenstar 30Ri Compactboiler154heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1871Greenstar 30Ri Compactboiler154ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1872Greenstar 30Ri Compactboiler154lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1873Greenstar 30Ri Compactboiler154servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1874Greenstar 30Ri Compactboiler154servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1875Greenstar 30Ri Compactboiler154maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1876Greenstar 30Ri Compactboiler154maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1877Greenstar 30Ri Compactboiler154maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1878Greenstar 30Ri Compactboiler154maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1879Greenstar 30Ri Compactboiler154emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1880Greenstar 30Ri Compactboiler154emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1881Greenstar 30Ri Compactboiler154pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1882Greenstar 30Ri Compactboiler154pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1883Greenstar 30Ri Compactboiler154pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1884Greenstar 30Ri Compactboiler154pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
1885Greenstar 30Ri Compactboiler154meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
1886Greenstar 30Ri Compactboiler154dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
1887Greenstar 30Ri Compactboiler154gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
1888Greenstar 30Ri Compactboiler154dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
1889Greenstar 30Ri Compactboiler154nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
1890Greenstar 30Ri Compactboiler154dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
1891Greenstar 30Ri Compactboiler154dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
1892Greenstar 30Ri Compactboiler154dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
1893Greenstar 30Ri Compactboiler154dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
1894Greenstar 30Ri Compactboiler154dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
1895Greenstar 30Ri Compactboiler154dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
1896Greenstar 30Ri Compactboiler154dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
1897Greenstar 30Ri Compactboiler154dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
1898Greenstar 30Ri Compactboiler154dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
1899Greenstar 30Ri Compactboiler154dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
1900Greenstar 30Ri Compactboiler154dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
1901Greenstar 30Ri Compactboiler154dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
1902Greenstar 30Ri Compactboiler154dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
1903Greenstar 30Ri Compactboiler154dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
1904Greenstar 30Ri Compactboiler154dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
1905Greenstar 30Ri Compactboiler154dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
1906Greenstar 30Ri Compactboiler154dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
1907Greenstar 30Ri Compactboiler154dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
1908Greenstar 30Ri Compactboiler154dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
1909Greenstar 30Ri Compactboiler154dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
1910Greenstar 30Ri Compactboiler154dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
1911Greenstar 30Ri Compactboiler154dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
1912Greenstar 30Ri Compactboiler154dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
1913Greenstar 30Ri Compactboiler154dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
1914Greenstar 30Ri Compactboiler154dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
1915Greenstar 30Ri Compactboiler154dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
1916Greenstar 30Ri Compactboiler154dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
1917Greenstar 30Ri Compactboiler154dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
1918Greenstar 30Ri Compactboiler154dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
1919Greenstar 30Ri Compactboiler154dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
1920Greenstar 30Ri Compactboiler154dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
1921Greenstar 30Ri Compactboiler154dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
1922Greenstar 30Ri Compactboiler154dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
1923Greenstar 30Ri Compactboiler154dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
1924Greenstar 30Ri Compactboiler154dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
1925Greenstar 30Ri Compactboiler154dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
1926Greenstar 30Ri Compactboiler154dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
1927Greenstar 30Ri Compactboiler154dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
1928Greenstar 30Ri Compactboiler154dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
1929Greenstar 30Ri Compactboiler154dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
1930Greenstar 30Ri Compactboiler154dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
1931Greenstar 30Ri Compactboiler154nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
1932Greenstar 30Ri Compactboiler154nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
1933Greenstar 30Ri Compactboiler154nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
1934Greenstar 30Ri Compactboiler154dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
1935Suprapur-oboiler155resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
1936Suprapur-oboiler155heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
1937Suprapur-oboiler155heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
1938Suprapur-oboiler155tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
1939Suprapur-oboiler155selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
1940Suprapur-oboiler155heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
1941Suprapur-oboiler155outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
1942Suprapur-oboiler155curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
1943Suprapur-oboiler155rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
1944Suprapur-oboiler155switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
1945Suprapur-oboiler155syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
1946Suprapur-oboiler155boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
1947Suprapur-oboiler155headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
1948Suprapur-oboiler155exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
1949Suprapur-oboiler155burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
1950Suprapur-oboiler155burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
1951Suprapur-oboiler155flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
1952Suprapur-oboiler155fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
1953Suprapur-oboiler155ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
1954Suprapur-oboiler155oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
1955Suprapur-oboiler155burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
1956Suprapur-oboiler155burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
1957Suprapur-oboiler155burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
1958Suprapur-oboiler155absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
1959Suprapur-oboiler155heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
1960Suprapur-oboiler155boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
1961Suprapur-oboiler155boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
1962Suprapur-oboiler155boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
1963Suprapur-oboiler155boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
1964Suprapur-oboiler155curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
1965Suprapur-oboiler155curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
1966Suprapur-oboiler155curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
1967Suprapur-oboiler155summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
1968Suprapur-oboiler155nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
1969Suprapur-oboiler155nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
1970Suprapur-oboiler155heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
1971Suprapur-oboiler155heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
1972Suprapur-oboiler155heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
1973Suprapur-oboiler155pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
1974Suprapur-oboiler155pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
1975Suprapur-oboiler155pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
1976Suprapur-oboiler155pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
1977Suprapur-oboiler155pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
1978Suprapur-oboiler155pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
1979Suprapur-oboiler155selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
1980Suprapur-oboiler155curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
1981Suprapur-oboiler155burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
1982Suprapur-oboiler155burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
1983Suprapur-oboiler155burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
1984Suprapur-oboiler155heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
1985Suprapur-oboiler155heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
1986Suprapur-oboiler155ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
1987Suprapur-oboiler155lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
1988Suprapur-oboiler155servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
1989Suprapur-oboiler155servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
1990Suprapur-oboiler155maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
1991Suprapur-oboiler155maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
1992Suprapur-oboiler155maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
1993Suprapur-oboiler155maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
1994Suprapur-oboiler155emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
1995Suprapur-oboiler155emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
1996Suprapur-oboiler155pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
1997Suprapur-oboiler155pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
1998Suprapur-oboiler155pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
1999Suprapur-oboiler155pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
2000Suprapur-oboiler155meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
2001Suprapur-oboiler155dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
2002Suprapur-oboiler155gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
2003Suprapur-oboiler155dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
2004Suprapur-oboiler155nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
2005Suprapur-oboiler155dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
2006Suprapur-oboiler155dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
2007Suprapur-oboiler155dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
2008Suprapur-oboiler155dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
2009Suprapur-oboiler155dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
2010Suprapur-oboiler155dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
2011Suprapur-oboiler155dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
2012Suprapur-oboiler155dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
2013Suprapur-oboiler155dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
2014Suprapur-oboiler155dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
2015Suprapur-oboiler155dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
2016Suprapur-oboiler155dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
2017Suprapur-oboiler155dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
2018Suprapur-oboiler155dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
2019Suprapur-oboiler155dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
2020Suprapur-oboiler155dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
2021Suprapur-oboiler155dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
2022Suprapur-oboiler155dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
2023Suprapur-oboiler155dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
2024Suprapur-oboiler155dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
2025Suprapur-oboiler155dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
2026Suprapur-oboiler155dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
2027Suprapur-oboiler155dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
2028Suprapur-oboiler155dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
2029Suprapur-oboiler155dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
2030Suprapur-oboiler155dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
2031Suprapur-oboiler155dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
2032Suprapur-oboiler155dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
2033Suprapur-oboiler155dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
2034Suprapur-oboiler155dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
2035Suprapur-oboiler155dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
2036Suprapur-oboiler155dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
2037Suprapur-oboiler155dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
2038Suprapur-oboiler155dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
2039Suprapur-oboiler155dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
2040Suprapur-oboiler155dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
2041Suprapur-oboiler155dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
2042Suprapur-oboiler155dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
2043Suprapur-oboiler155dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
2044Suprapur-oboiler155dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
2045Suprapur-oboiler155dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
2046Suprapur-oboiler155nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
2047Suprapur-oboiler155nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
2048Suprapur-oboiler155nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
2049Suprapur-oboiler155dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
2050Cerapur Aeroboiler167resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
2051Cerapur Aeroboiler167heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
2052Cerapur Aeroboiler167heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
2053Cerapur Aeroboiler167tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
2054Cerapur Aeroboiler167selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
2055Cerapur Aeroboiler167heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
2056Cerapur Aeroboiler167outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
2057Cerapur Aeroboiler167curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
2058Cerapur Aeroboiler167rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
2059Cerapur Aeroboiler167switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
2060Cerapur Aeroboiler167syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
2061Cerapur Aeroboiler167boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
2062Cerapur Aeroboiler167headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
2063Cerapur Aeroboiler167exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
2064Cerapur Aeroboiler167burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
2065Cerapur Aeroboiler167burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
2066Cerapur Aeroboiler167flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
2067Cerapur Aeroboiler167fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
2068Cerapur Aeroboiler167ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
2069Cerapur Aeroboiler167oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
2070Cerapur Aeroboiler167burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
2071Cerapur Aeroboiler167burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
2072Cerapur Aeroboiler167burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
2073Cerapur Aeroboiler167absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
2074Cerapur Aeroboiler167heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
2075Cerapur Aeroboiler167boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
2076Cerapur Aeroboiler167boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
2077Cerapur Aeroboiler167boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
2078Cerapur Aeroboiler167boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
2079Cerapur Aeroboiler167curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
2080Cerapur Aeroboiler167curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
2081Cerapur Aeroboiler167curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
2082Cerapur Aeroboiler167summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
2083Cerapur Aeroboiler167nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
2084Cerapur Aeroboiler167nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
2085Cerapur Aeroboiler167heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
2086Cerapur Aeroboiler167heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
2087Cerapur Aeroboiler167heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
2088Cerapur Aeroboiler167pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
2089Cerapur Aeroboiler167pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
2090Cerapur Aeroboiler167pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
2091Cerapur Aeroboiler167pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
2092Cerapur Aeroboiler167pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
2093Cerapur Aeroboiler167pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
2094Cerapur Aeroboiler167selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
2095Cerapur Aeroboiler167curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
2096Cerapur Aeroboiler167burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
2097Cerapur Aeroboiler167burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
2098Cerapur Aeroboiler167burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
2099Cerapur Aeroboiler167heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
2100Cerapur Aeroboiler167heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
2101Cerapur Aeroboiler167ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
2102Cerapur Aeroboiler167lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
2103Cerapur Aeroboiler167servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
2104Cerapur Aeroboiler167servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
2105Cerapur Aeroboiler167maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
2106Cerapur Aeroboiler167maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
2107Cerapur Aeroboiler167maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
2108Cerapur Aeroboiler167maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
2109Cerapur Aeroboiler167emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
2110Cerapur Aeroboiler167emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
2111Cerapur Aeroboiler167pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
2112Cerapur Aeroboiler167pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
2113Cerapur Aeroboiler167pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
2114Cerapur Aeroboiler167pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
2115Cerapur Aeroboiler167meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
2116Cerapur Aeroboiler167dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
2117Cerapur Aeroboiler167gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
2118Cerapur Aeroboiler167dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
2119Cerapur Aeroboiler167nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
2120Cerapur Aeroboiler167dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
2121Cerapur Aeroboiler167dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
2122Cerapur Aeroboiler167dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
2123Cerapur Aeroboiler167dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
2124Cerapur Aeroboiler167dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
2125Cerapur Aeroboiler167dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
2126Cerapur Aeroboiler167dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
2127Cerapur Aeroboiler167dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
2128Cerapur Aeroboiler167dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
2129Cerapur Aeroboiler167dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
2130Cerapur Aeroboiler167dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
2131Cerapur Aeroboiler167dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
2132Cerapur Aeroboiler167dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
2133Cerapur Aeroboiler167dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
2134Cerapur Aeroboiler167dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
2135Cerapur Aeroboiler167dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
2136Cerapur Aeroboiler167dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
2137Cerapur Aeroboiler167dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
2138Cerapur Aeroboiler167dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
2139Cerapur Aeroboiler167dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
2140Cerapur Aeroboiler167dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
2141Cerapur Aeroboiler167dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
2142Cerapur Aeroboiler167dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
2143Cerapur Aeroboiler167dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
2144Cerapur Aeroboiler167dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
2145Cerapur Aeroboiler167dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
2146Cerapur Aeroboiler167dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
2147Cerapur Aeroboiler167dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
2148Cerapur Aeroboiler167dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
2149Cerapur Aeroboiler167dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
2150Cerapur Aeroboiler167dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
2151Cerapur Aeroboiler167dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
2152Cerapur Aeroboiler167dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
2153Cerapur Aeroboiler167dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
2154Cerapur Aeroboiler167dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
2155Cerapur Aeroboiler167dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
2156Cerapur Aeroboiler167dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
2157Cerapur Aeroboiler167dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
2158Cerapur Aeroboiler167dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
2159Cerapur Aeroboiler167dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
2160Cerapur Aeroboiler167dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
2161Cerapur Aeroboiler167nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
2162Cerapur Aeroboiler167nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
2163Cerapur Aeroboiler167nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
2164Cerapur Aeroboiler167dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
2165Hybrid Heatpumpboiler168resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
2166Hybrid Heatpumpboiler168heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
2167Hybrid Heatpumpboiler168heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
2168Hybrid Heatpumpboiler168tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
2169Hybrid Heatpumpboiler168selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
2170Hybrid Heatpumpboiler168heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
2171Hybrid Heatpumpboiler168outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
2172Hybrid Heatpumpboiler168curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
2173Hybrid Heatpumpboiler168rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
2174Hybrid Heatpumpboiler168switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
2175Hybrid Heatpumpboiler168syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
2176Hybrid Heatpumpboiler168boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
2177Hybrid Heatpumpboiler168headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
2178Hybrid Heatpumpboiler168exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
2179Hybrid Heatpumpboiler168burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
2180Hybrid Heatpumpboiler168burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
2181Hybrid Heatpumpboiler168flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
2182Hybrid Heatpumpboiler168fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
2183Hybrid Heatpumpboiler168ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
2184Hybrid Heatpumpboiler168oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
2185Hybrid Heatpumpboiler168burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
2186Hybrid Heatpumpboiler168burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
2187Hybrid Heatpumpboiler168burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
2188Hybrid Heatpumpboiler168absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
2189Hybrid Heatpumpboiler168heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
2190Hybrid Heatpumpboiler168boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
2191Hybrid Heatpumpboiler168boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
2192Hybrid Heatpumpboiler168boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
2193Hybrid Heatpumpboiler168boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
2194Hybrid Heatpumpboiler168curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
2195Hybrid Heatpumpboiler168curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
2196Hybrid Heatpumpboiler168curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
2197Hybrid Heatpumpboiler168summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
2198Hybrid Heatpumpboiler168nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
2199Hybrid Heatpumpboiler168nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
2200Hybrid Heatpumpboiler168heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
2201Hybrid Heatpumpboiler168heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
2202Hybrid Heatpumpboiler168heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
2203Hybrid Heatpumpboiler168pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
2204Hybrid Heatpumpboiler168pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
2205Hybrid Heatpumpboiler168pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
2206Hybrid Heatpumpboiler168pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
2207Hybrid Heatpumpboiler168pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
2208Hybrid Heatpumpboiler168pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
2209Hybrid Heatpumpboiler168selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
2210Hybrid Heatpumpboiler168curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
2211Hybrid Heatpumpboiler168burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
2212Hybrid Heatpumpboiler168burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
2213Hybrid Heatpumpboiler168burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
2214Hybrid Heatpumpboiler168heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
2215Hybrid Heatpumpboiler168heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
2216Hybrid Heatpumpboiler168ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
2217Hybrid Heatpumpboiler168lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
2218Hybrid Heatpumpboiler168servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
2219Hybrid Heatpumpboiler168servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
2220Hybrid Heatpumpboiler168maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
2221Hybrid Heatpumpboiler168maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
2222Hybrid Heatpumpboiler168maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
2223Hybrid Heatpumpboiler168maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
2224Hybrid Heatpumpboiler168emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
2225Hybrid Heatpumpboiler168emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
2226Hybrid Heatpumpboiler168pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
2227Hybrid Heatpumpboiler168pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
2228Hybrid Heatpumpboiler168pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
2229Hybrid Heatpumpboiler168pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
2230Hybrid Heatpumpboiler168meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
2231Hybrid Heatpumpboiler168dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
2232Hybrid Heatpumpboiler168gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
2233Hybrid Heatpumpboiler168dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
2234Hybrid Heatpumpboiler168nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
2235Hybrid Heatpumpboiler168dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
2236Hybrid Heatpumpboiler168dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
2237Hybrid Heatpumpboiler168dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
2238Hybrid Heatpumpboiler168dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
2239Hybrid Heatpumpboiler168dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
2240Hybrid Heatpumpboiler168dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
2241Hybrid Heatpumpboiler168dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
2242Hybrid Heatpumpboiler168dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
2243Hybrid Heatpumpboiler168dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
2244Hybrid Heatpumpboiler168dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
2245Hybrid Heatpumpboiler168dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
2246Hybrid Heatpumpboiler168dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
2247Hybrid Heatpumpboiler168dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
2248Hybrid Heatpumpboiler168dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
2249Hybrid Heatpumpboiler168dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
2250Hybrid Heatpumpboiler168dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
2251Hybrid Heatpumpboiler168dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
2252Hybrid Heatpumpboiler168dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
2253Hybrid Heatpumpboiler168dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
2254Hybrid Heatpumpboiler168dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
2255Hybrid Heatpumpboiler168dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
2256Hybrid Heatpumpboiler168dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
2257Hybrid Heatpumpboiler168dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
2258Hybrid Heatpumpboiler168dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
2259Hybrid Heatpumpboiler168dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
2260Hybrid Heatpumpboiler168dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
2261Hybrid Heatpumpboiler168dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
2262Hybrid Heatpumpboiler168dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
2263Hybrid Heatpumpboiler168dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
2264Hybrid Heatpumpboiler168dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
2265Hybrid Heatpumpboiler168dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
2266Hybrid Heatpumpboiler168dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
2267Hybrid Heatpumpboiler168dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
2268Hybrid Heatpumpboiler168dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
2269Hybrid Heatpumpboiler168dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
2270Hybrid Heatpumpboiler168dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
2271Hybrid Heatpumpboiler168dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
2272Hybrid Heatpumpboiler168dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
2273Hybrid Heatpumpboiler168dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
2274Hybrid Heatpumpboiler168dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
2275Hybrid Heatpumpboiler168dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
2276Hybrid Heatpumpboiler168nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
2277Hybrid Heatpumpboiler168nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
2278Hybrid Heatpumpboiler168nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
2279Hybrid Heatpumpboiler168dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
2280Logano GB212boiler170resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
2281Logano GB212boiler170heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
2282Logano GB212boiler170heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
2283Logano GB212boiler170tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
2284Logano GB212boiler170selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
2285Logano GB212boiler170heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
2286Logano GB212boiler170outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
2287Logano GB212boiler170curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
2288Logano GB212boiler170rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
2289Logano GB212boiler170switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
2290Logano GB212boiler170syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
2291Logano GB212boiler170boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
2292Logano GB212boiler170headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
2293Logano GB212boiler170exhausttempexhaust temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_exhaust_temperaturesensor.boiler_exhausttemp501/102441
2294Logano GB212boiler170burngasgasbooleanfalsebinary_sensor.boiler_gasbinary_sensor.boiler_burngas5012451
2295Logano GB212boiler170burngas2gas stage 2booleanfalsebinary_sensor.boiler_gas_stage_2binary_sensor.boiler_burngas25012461
2296Logano GB212boiler170flamecurrflame currentuint16 (>=0<=3199)µAfalsesensor.boiler_flame_currentsensor.boiler_flamecurr501/102471
2297Logano GB212boiler170fanworkfanbooleanfalsebinary_sensor.boiler_fanbinary_sensor.boiler_fanwork5012481
2298Logano GB212boiler170ignworkignitionbooleanfalsebinary_sensor.boiler_ignitionbinary_sensor.boiler_ignwork5012491
2299Logano GB212boiler170oilpreheatoil preheatingbooleanfalsebinary_sensor.boiler_oil_preheatingbinary_sensor.boiler_oilpreheat5012501
2300Logano GB212boiler170burnminpowerburner min poweruint8 (>=0<=100)%truenumber.boiler_burner_min_powernumber.boiler_burnminpower5012511
2301Logano GB212boiler170burnmaxpowerburner max poweruint8 (>=0<=254)%truenumber.boiler_burner_max_powernumber.boiler_burnmaxpower5012521
2302Logano GB212boiler170burnminperiodburner min perioduint8 (>=0<=120)minutestruenumber.boiler_burner_min_periodnumber.boiler_burnminperiod5012531
2303Logano GB212boiler170absburnpowburner current power (absolute)uint8 (>=0<=100)%falsesensor.boiler_burner_current_power_(absolute)sensor.boiler_absburnpow5012541
2304Logano GB212boiler170heatblockheating blockuint16 (>=0<=3199)Cfalsesensor.boiler_heating_blocksensor.boiler_heatblock501/102551
2305Logano GB212boiler170boilhystonhysteresis on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_on_temperaturenumber.boiler_boilhyston5012561
2306Logano GB212boiler170boilhystoffhysteresis off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_off_temperaturenumber.boiler_boilhystoff5012571
2307Logano GB212boiler170boil2hystonhysteresis stage 2 on temperatureint8 (>=-20<=0)Ctruenumber.boiler_hysteresis_stage_2_on_temperaturenumber.boiler_boil2hyston5012581
2308Logano GB212boiler170boil2hystoffhysteresis stage 2 off temperatureint8 (>=0<=20)Ctruenumber.boiler_hysteresis_stage_2_off_temperaturenumber.boiler_boil2hystoff5012591
2309Logano GB212boiler170curveonheatingcurve onbooleantrueswitch.boiler_heatingcurve_onswitch.boiler_curveon5012601
2310Logano GB212boiler170curvebaseheatingcurve baseuint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_basenumber.boiler_curvebase5012611
2311Logano GB212boiler170curveendheatingcurve enduint8 (>=20<=90)Ctruenumber.boiler_heatingcurve_endnumber.boiler_curveend5012621
2312Logano GB212boiler170summertempsummer temperatureuint8 (>=0<=45)Ctruenumber.boiler_summer_temperaturenumber.boiler_summertemp5012631
2313Logano GB212boiler170nofrostmodenofrost modebooleantrueswitch.boiler_nofrost_modeswitch.boiler_nofrostmode5012641
2314Logano GB212boiler170nofrosttempnofrost temperatureuint8 (>=0<=10)Ctruenumber.boiler_nofrost_temperaturenumber.boiler_nofrosttemp5012651
2315Logano GB212boiler170heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
2316Logano GB212boiler170heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
2317Logano GB212boiler170heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
2318Logano GB212boiler170pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
2319Logano GB212boiler170pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
2320Logano GB212boiler170pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
2321Logano GB212boiler170pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
2322Logano GB212boiler170pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
2323Logano GB212boiler170pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
2324Logano GB212boiler170selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
2325Logano GB212boiler170curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
2326Logano GB212boiler170burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
2327Logano GB212boiler170burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
2328Logano GB212boiler170burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
2329Logano GB212boiler170heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
2330Logano GB212boiler170heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
2331Logano GB212boiler170ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
2332Logano GB212boiler170lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
2333Logano GB212boiler170servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
2334Logano GB212boiler170servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
2335Logano GB212boiler170maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
2336Logano GB212boiler170maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
2337Logano GB212boiler170maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
2338Logano GB212boiler170maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
2339Logano GB212boiler170emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
2340Logano GB212boiler170emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
2341Logano GB212boiler170pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
2342Logano GB212boiler170pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
2343Logano GB212boiler170pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
2344Logano GB212boiler170pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
2345Logano GB212boiler170meterheatmeter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/10952
2346Logano GB212boiler170dhw.metermeteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/1022
2347Logano GB212boiler170gasmeterheatgas meter heatinguint24 (>=0<=1677721)kWhfalsesensor.boiler_gas_meter_heatingsensor.boiler_gasmeterheat501/102662
2348Logano GB212boiler170dhw.gasmetergas meteruint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_gas_metersensor.boiler_dhw_gasmeter591/10702
2349Logano GB212boiler170nrgheat2energy heating 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_energy_heating_2sensor.boiler_nrgheat2501/102682
2350Logano GB212boiler170dhw.nrg2energy 2uint24 (>=0<=1677721)kWhfalsesensor.boiler_dhw_energy_2sensor.boiler_dhw_nrg2591/10722
2351Logano GB212boiler170dhw.tapactivatedturn on/offbooleantrueswitch.boiler_dhw_turn_on/offswitch.boiler_dhw_tapactivated591281
2352Logano GB212boiler170dhw.settempset temperatureuint8 (>=0<=254)Cfalsesensor.boiler_dhw_set_temperaturesensor.boiler_dhw_settemp591291
2353Logano GB212boiler170dhw.seltempselected temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_temperaturenumber.boiler_dhw_seltemp591301
2354Logano GB212boiler170dhw.seltemplowselected lower temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_lower_temperaturenumber.boiler_dhw_seltemplow591311
2355Logano GB212boiler170dhw.tempecoplusselected eco+ temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_selected_eco+_temperaturenumber.boiler_dhw_tempecoplus591321
2356Logano GB212boiler170dhw.seltempoffselected temperature for offuint8 (>=0<=254)Cfalsesensor.boiler_dhw_selected_temperature_for_offsensor.boiler_dhw_seltempoff591331
2357Logano GB212boiler170dhw.seltempsinglesingle charge temperatureuint8 (>=0<=254)Ctruenumber.boiler_dhw_single_charge_temperaturenumber.boiler_dhw_seltempsingle591341
2358Logano GB212boiler170dhw.solartempsolar boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_solar_boiler_temperaturesensor.boiler_dhw_solartemp591/10351
2359Logano GB212boiler170dhw.typetypeenum [off\|flow\|buffered flow\|buffer\|layered buffer]falsesensor.boiler_dhw_typesensor.boiler_dhw_type591361
2360Logano GB212boiler170dhw.comfortcomfortenum [hot\|eco\|intelligent]trueselect.boiler_dhw_comfortselect.boiler_dhw_comfort591371
2361Logano GB212boiler170dhw.comfort1comfort modeenum [high comfort\|eco]trueselect.boiler_dhw_comfort_modeselect.boiler_dhw_comfort1591381
2362Logano GB212boiler170dhw.flowtempoffsetflow temperature offsetuint8 (>=0<=100)Ctruenumber.boiler_dhw_flow_temperature_offsetnumber.boiler_dhw_flowtempoffset591391
2363Logano GB212boiler170dhw.chargeoptimizationcharge optimizationbooleantrueswitch.boiler_dhw_charge_optimizationswitch.boiler_dhw_chargeoptimization591401
2364Logano GB212boiler170dhw.maxpowermax poweruint8 (>=0<=254)%truenumber.boiler_dhw_max_powernumber.boiler_dhw_maxpower591411
2365Logano GB212boiler170dhw.maxtempmaximum temperatureuint8 (>=0<=80)Ctruenumber.boiler_dhw_maximum_temperaturenumber.boiler_dhw_maxtemp591421
2366Logano GB212boiler170dhw.circpumpcirculation pump availablebooleantrueswitch.boiler_dhw_circulation_pump_availableswitch.boiler_dhw_circpump591431
2367Logano GB212boiler170dhw.chargetypecharging typeenum [chargepump\|3-way valve]falsesensor.boiler_dhw_charging_typesensor.boiler_dhw_chargetype591441
2368Logano GB212boiler170dhw.hystonhysteresis on temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_on_temperaturenumber.boiler_dhw_hyston591451
2369Logano GB212boiler170dhw.hystoffhysteresis off temperatureint8 (>=-126<=126)Ctruenumber.boiler_dhw_hysteresis_off_temperaturenumber.boiler_dhw_hystoff591461
2370Logano GB212boiler170dhw.disinfectiontempdisinfection temperatureuint8 (>=60<=80)Ctruenumber.boiler_dhw_disinfection_temperaturenumber.boiler_dhw_disinfectiontemp591471
2371Logano GB212boiler170dhw.circmodecirculation pump modeenum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous]trueselect.boiler_dhw_circulation_pump_modeselect.boiler_dhw_circmode591481
2372Logano GB212boiler170dhw.circcirculation activebooleantrueswitch.boiler_dhw_circulation_activeswitch.boiler_dhw_circ591491
2373Logano GB212boiler170dhw.curtempcurrent intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_intern_temperaturesensor.boiler_dhw_curtemp591/10501
2374Logano GB212boiler170dhw.curtemp2current extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_current_extern_temperaturesensor.boiler_dhw_curtemp2591/10511
2375Logano GB212boiler170dhw.curflowcurrent tap water flowuint8 (>=0<=25)l/minfalsesensor.boiler_dhw_current_tap_water_flowsensor.boiler_dhw_curflow591/10521
2376Logano GB212boiler170dhw.storagetemp1storage intern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_intern_temperaturesensor.boiler_dhw_storagetemp1591/10531
2377Logano GB212boiler170dhw.storagetemp2storage extern temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_storage_extern_temperaturesensor.boiler_dhw_storagetemp2591/10541
2378Logano GB212boiler170dhw.activatedactivatedbooleantrueswitch.boiler_dhw_activatedswitch.boiler_dhw_activated591551
2379Logano GB212boiler170dhw.onetimeone time chargingbooleantrueswitch.boiler_dhw_one_time_chargingswitch.boiler_dhw_onetime591561
2380Logano GB212boiler170dhw.disinfectingdisinfectingbooleantrueswitch.boiler_dhw_disinfectingswitch.boiler_dhw_disinfecting591571
2381Logano GB212boiler170dhw.chargingchargingbooleanfalsebinary_sensor.boiler_dhw_chargingbinary_sensor.boiler_dhw_charging591581
2382Logano GB212boiler170dhw.rechargingrechargingbooleanfalsebinary_sensor.boiler_dhw_rechargingbinary_sensor.boiler_dhw_recharging591591
2383Logano GB212boiler170dhw.tempoktemperature okbooleanfalsebinary_sensor.boiler_dhw_temperature_okbinary_sensor.boiler_dhw_tempok591601
2384Logano GB212boiler170dhw.activeactivebooleanfalsebinary_sensor.boiler_dhw_activebinary_sensor.boiler_dhw_active591611
2385Logano GB212boiler170dhw.3wayvalve3-way valve activebooleanfalsebinary_sensor.boiler_dhw_3-way_valve_activebinary_sensor.boiler_dhw_3wayvalve591621
2386Logano GB212boiler170dhw.chargepumpcharge pumpbooleanfalsebinary_sensor.boiler_dhw_charge_pumpbinary_sensor.boiler_dhw_chargepump591631
2387Logano GB212boiler170dhw.mixertempmixer temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_dhw_mixer_temperaturesensor.boiler_dhw_mixertemp591/10641
2388Logano GB212boiler170dhw.cylmiddletempcylinder middle temperature (TS3)uint16 (>=0<=3199)Cfalsesensor.boiler_dhw_cylinder_middle_temperature_(TS3)sensor.boiler_dhw_cylmiddletemp591/10651
2389Logano GB212boiler170dhw.startsstartsuint24 (>=0<=16777214)falsesensor.boiler_dhw_startssensor.boiler_dhw_starts591662
2390Logano GB212boiler170dhw.workmactive timetime (>=0<=16777214)minutesfalsesensor.boiler_dhw_active_timesensor.boiler_dhw_workm591682
2391Logano GB212boiler170nompowernominal Poweruint8 (>=0<=254)kWtruenumber.boiler_nominal_Powernumber.boiler_nompower5012701
2392Logano GB212boiler170nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
2393Logano GB212boiler170nrgheatenergy heatinguint24 (>=0<=10000000)kWhtruenumber.boiler_energy_heatingnumber.boiler_nrgheat501/100852
2394Logano GB212boiler170dhw.nrgenergyuint24 (>=0<=10000000)kWhtruenumber.boiler_dhw_energynumber.boiler_dhw_nrg591/10002
2395Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172resetresetcmd [-\|maintenance\|error\|history\|message]truesensor.boiler_resetsensor.boiler_reset50101
2396Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatingoffforce heating offbooleantrueswitch.boiler_force_heating_offswitch.boiler_heatingoff50111
2397Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatingactiveheating activebooleanfalsebinary_sensor.boiler_heating_activebinary_sensor.boiler_heatingactive50121
2398Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172tapwateractivetapwater activebooleanfalsebinary_sensor.boiler_tapwater_activebinary_sensor.boiler_tapwateractive50131
2399Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172selflowtempselected flow temperatureuint8 (>=0<=90)Ctruenumber.boiler_selected_flow_temperaturenumber.boiler_selflowtemp50141
2400Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatingpumpmodheating pump modulationuint8 (>=0<=100)%falsesensor.boiler_heating_pump_modulationsensor.boiler_heatingpumpmod50151
2401Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172outdoortempoutside temperatureint16 (>=-3199<=3199)Cfalsesensor.boiler_outside_temperaturesensor.boiler_outdoortemp501/1061
2402Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172curflowtempcurrent flow temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_current_flow_temperaturesensor.boiler_curflowtemp501/1071
2403Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172rettempreturn temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_return_temperaturesensor.boiler_rettemp501/1081
2404Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172switchtempmixing switch temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_mixing_switch_temperaturesensor.boiler_switchtemp501/1091
2405Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172syspresssystem pressureuint8 (>=0<=25)barfalsesensor.boiler_system_pressuresensor.boiler_syspress501/10101
2406Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172boiltempactual boiler temperatureuint16 (>=0<=3199)Cfalsesensor.boiler_actual_boiler_temperaturesensor.boiler_boiltemp501/10111
2407Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172headertemplow loss headeruint16 (>=0<=3199)Cfalsesensor.boiler_low_loss_headersensor.boiler_headertemp501/10121
2408Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatingactivatedheating activatedbooleantrueswitch.boiler_heating_activatedswitch.boiler_heatingactivated501131
2409Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatingtempheating temperatureuint8 (>=0<=90)Ctruenumber.boiler_heating_temperaturenumber.boiler_heatingtemp501141
2410Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatingpumpheating pumpbooleanfalsebinary_sensor.boiler_heating_pumpbinary_sensor.boiler_heatingpump501151
2411Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pumpmodmaxboiler pump max poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_max_powernumber.boiler_pumpmodmax501161
2412Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pumpmodminboiler pump min poweruint8 (>=0<=100)%truenumber.boiler_boiler_pump_min_powernumber.boiler_pumpmodmin501171
2413Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pumpmodeboiler pump modeenum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4]trueselect.boiler_boiler_pump_modeselect.boiler_pumpmode501181
2414Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pumpcharacterboiler pump characteristicenum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar]trueselect.boiler_boiler_pump_characteristicselect.boiler_pumpcharacter501191
2415Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pumpdelaypump delayuint8 (>=0<=60)minutestruenumber.boiler_pump_delaynumber.boiler_pumpdelay501201
2416Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pumpontemppump logic temperatureuint8 (>=0<=60)Ctruenumber.boiler_pump_logic_temperaturenumber.boiler_pumpontemp501211
2417Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172selburnpowburner selected max poweruint8 (>=0<=254)%truenumber.boiler_burner_selected_max_powernumber.boiler_selburnpow501221
2418Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172curburnpowburner current poweruint8 (>=0<=100)%falsesensor.boiler_burner_current_powersensor.boiler_curburnpow501231
2419Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172burnstartsburner startsuint24 (>=0<=16777214)falsesensor.boiler_burner_startssensor.boiler_burnstarts501242
2420Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172burnworkmintotal burner operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_burner_operating_timesensor.boiler_burnworkmin501262
2421Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172burn2workminburner stage 2 operating timetime (>=0<=16777214)minutesfalsesensor.boiler_burner_stage_2_operating_timesensor.boiler_burn2workmin501282
2422Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatworkmintotal heat operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_heat_operating_timesensor.boiler_heatworkmin501302
2423Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatstartsburner starts heatinguint24 (>=0<=16777214)falsesensor.boiler_burner_starts_heatingsensor.boiler_heatstarts501322
2424Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172ubauptimetotal UBA operating timetime (>=0<=16777214)minutesfalsesensor.boiler_total_UBA_operating_timesensor.boiler_ubauptime501342
2425Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172lastcodelast error codestringfalsesensor.boiler_last_error_codesensor.boiler_lastcode5013628
2426Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172servicecodeservice codestringfalsesensor.boiler_service_codesensor.boiler_servicecode501642
2427Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172servicecodenumberservice code numberuint16 (>=0<=31999)falsesensor.boiler_service_code_numbersensor.boiler_servicecodenumber501661
2428Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172maintenancemessagemaintenance messagestringfalsesensor.boiler_maintenance_messagesensor.boiler_maintenancemessage501672
2429Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172maintenancemaintenance scheduledenum [off\|time\|date\|manual]trueselect.boiler_maintenance_scheduledselect.boiler_maintenance501691
2430Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172maintenancetimetime to next maintenanceuint16 (>=0<=31999)hourstruenumber.boiler_time_to_next_maintenancenumber.boiler_maintenancetime501701
2431Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172maintenancedatenext maintenance datestringtruesensor.boiler_next_maintenance_datesensor.boiler_maintenancedate501716
2432Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172emergencyopsemergency operationbooleantrueswitch.boiler_emergency_operationswitch.boiler_emergencyops501771
2433Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172emergencytempemergency temperatureuint8 (>=15<=70)Ctruenumber.boiler_emergency_temperaturenumber.boiler_emergencytemp501781
2434Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pc0flowFlow PC0int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC0sensor.boiler_pc0flow501791
2435Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pc1flowFlow PC1int16 (>=-31999<=31999)l/hfalsesensor.boiler_Flow_PC1sensor.boiler_pc1flow501801
2436Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pc1onPC1booleanfalsebinary_sensor.boiler_PC1binary_sensor.boiler_pc1on501811
2437Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pc1ratePC1 rateuint8 (>=0<=100)%falsesensor.boiler_PC1_ratesensor.boiler_pc1rate501821
2438Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgtotaltotal energyuint24 (>=0<=167772)kWhfalsesensor.boiler_total_energysensor.boiler_nrgtotal501/100832
2439Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.nrgenergyuint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_energysensor.boiler_dhw_nrg591/10002
2440Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgheatenergy heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_heatingsensor.boiler_nrgheat501/100852
2441Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgcoolenergy coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_energy_coolingsensor.boiler_nrgcool501/100872
2442Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172metertotalmeter totaluint24 (>=0<=167772)kWhfalsesensor.boiler_meter_totalsensor.boiler_metertotal501/100892
2443Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172metercompmeter compressoruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_compressorsensor.boiler_metercomp501/100912
2444Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172metereheatmeter e-heateruint24 (>=0<=167772)kWhfalsesensor.boiler_meter_e-heatersensor.boiler_metereheat501/100932
2445Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172meterheatmeter heatinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_heatingsensor.boiler_meterheat501/100952
2446Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172metercoolmeter coolinguint24 (>=0<=167772)kWhfalsesensor.boiler_meter_coolingsensor.boiler_metercool501/100972
2447Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.metermeteruint24 (>=0<=167772)kWhfalsesensor.boiler_dhw_metersensor.boiler_dhw_meter591/10022
2448Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172uptimetotalheatpump total uptimetime (>=0<=279620)minutesfalsesensor.boiler_heatpump_total_uptimesensor.boiler_uptimetotal501/60992
2449Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172uptimecontroltotal operating time heattime (>=0<=279620)minutesfalsesensor.boiler_total_operating_time_heatsensor.boiler_uptimecontrol501/601012
2450Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172uptimecompheatingoperating time compressor heatingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_heatingsensor.boiler_uptimecompheating501/601032
2451Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172uptimecompcoolingoperating time compressor coolingtime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_coolingsensor.boiler_uptimecompcooling501/601052
2452Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.uptimecompoperating time compressortime (>=0<=279620)minutesfalsesensor.boiler_dhw_operating_time_compressorsensor.boiler_dhw_uptimecomp591/6042
2453Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172uptimecomppooloperating time compressor pooltime (>=0<=279620)minutesfalsesensor.boiler_operating_time_compressor_poolsensor.boiler_uptimecomppool501/601072
2454Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172totalcompstartstotal compressor control startsuint24 (>=0<=16777214)falsesensor.boiler_total_compressor_control_startssensor.boiler_totalcompstarts5011092
2455Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172heatingstartsheating control startsuint24 (>=0<=16777214)falsesensor.boiler_heating_control_startssensor.boiler_heatingstarts5011112
2456Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172coolingstartscooling control startsuint24 (>=0<=16777214)falsesensor.boiler_cooling_control_startssensor.boiler_coolingstarts5011132
2457Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.startshpstarts hpuint24 (>=0<=16777214)falsesensor.boiler_dhw_starts_hpsensor.boiler_dhw_startshp59162
2458Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172poolstartspool control startsuint24 (>=0<=16777214)falsesensor.boiler_pool_control_startssensor.boiler_poolstarts5011152
2459Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgconstotaltotal energy consumptionuint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_consumptionsensor.boiler_nrgconstotal5011172
2460Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgconscomptotaltotal energy consumption compressoruint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_consumption_compressorsensor.boiler_nrgconscomptotal5011192
2461Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgconscompheatingenergy consumption compressor heatinguint24 (>=0<=16777214)kWhfalsesensor.boiler_energy_consumption_compressor_heatingsensor.boiler_nrgconscompheating5011212
2462Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.nrgconscompenergy consumption compressoruint24 (>=0<=16777214)kWhfalsesensor.boiler_dhw_energy_consumption_compressorsensor.boiler_dhw_nrgconscomp59182
2463Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgconscompcoolingenergy consumption compressor coolinguint24 (>=0<=16777214)kWhfalsesensor.boiler_energy_consumption_compressor_coolingsensor.boiler_nrgconscompcooling5011232
2464Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgconscomppoolenergy consumption compressor pooluint24 (>=0<=16777214)kWhfalsesensor.boiler_energy_consumption_compressor_poolsensor.boiler_nrgconscomppool5011252
2465Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxelecheatnrgconstotaltotal aux elec. heater energy consumptionuint24 (>=0<=16777214)kWhfalsesensor.boiler_total_aux_elec._heater_energy_consumptionsensor.boiler_auxelecheatnrgconstotal5011272
2466Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxelecheatnrgconsheatingaux elec. heater energy consumption heatinguint24 (>=0<=16777214)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_heatingsensor.boiler_auxelecheatnrgconsheating5011292
2467Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.auxelecheatnrgconsaux elec. heater energy consumptionuint24 (>=0<=16777214)kWhfalsesensor.boiler_dhw_aux_elec._heater_energy_consumptionsensor.boiler_dhw_auxelecheatnrgcons591102
2468Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172auxelecheatnrgconspoolaux elec. heater energy consumption pooluint24 (>=0<=16777214)kWhfalsesensor.boiler_aux_elec._heater_energy_consumption_poolsensor.boiler_auxelecheatnrgconspool5011312
2469Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgsupptotaltotal energy supplieduint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_suppliedsensor.boiler_nrgsupptotal5011332
2470Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgsuppheatingtotal energy supplied heatinguint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_supplied_heatingsensor.boiler_nrgsuppheating5011352
2471Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172dhw.nrgsupptotal energy warm supplieduint24 (>=0<=16777214)kWhfalsesensor.boiler_dhw_total_energy_warm_suppliedsensor.boiler_dhw_nrgsupp591122
2472Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgsuppcoolingtotal energy supplied coolinguint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_supplied_coolingsensor.boiler_nrgsuppcooling5011372
2473Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172nrgsupppooltotal energy supplied pooluint24 (>=0<=16777214)kWhfalsesensor.boiler_total_energy_supplied_poolsensor.boiler_nrgsupppool5011392
2474Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hppowercompressor power outputuint16 (>=0<=3199)kWfalsesensor.boiler_compressor_power_outputsensor.boiler_hppower501/101411
2475Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpmaxpowercompressor max poweruint8 (>=0<=100)%truenumber.boiler_compressor_max_powernumber.boiler_hpmaxpower5011421
2476Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172pvmaxcomppv compressor max poweruint8 (>=0<=25)kWtruenumber.boiler_pv_compressor_max_powernumber.boiler_pvmaxcomp501/101431
2477Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172powerreductionpower reductionuint8 (>=30<=60)%truenumber.boiler_power_reductionnumber.boiler_powerreduction50101441
2478Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpsetdiffpressset differential pressureuint8 (>=150<=750)mbartruenumber.boiler_set_differential_pressurenumber.boiler_hpsetdiffpress50501451
2479Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpcomponhp compressorbooleanfalsebinary_sensor.boiler_hp_compressorbinary_sensor.boiler_hpcompon5011461
2480Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpactivitycompressor activityenum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm]falsesensor.boiler_compressor_activitysensor.boiler_hpactivity5011471
2481Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpbrinepumpspdbrine pump speeduint8 (>=0<=100)%falsesensor.boiler_brine_pump_speedsensor.boiler_hpbrinepumpspd5011481
2482Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpswitchvalveswitch valvebooleanfalsebinary_sensor.boiler_switch_valvebinary_sensor.boiler_hpswitchvalve5011491
2483Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpcompspdcompressor speeduint8 (>=0<=100)%falsesensor.boiler_compressor_speedsensor.boiler_hpcompspd5011501
2484Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpcircspdcirculation pump speeduint8 (>=0<=100)%falsesensor.boiler_circulation_pump_speedsensor.boiler_hpcircspd5011511
2485Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpbrineinbrine in/evaporatorint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_in/evaporatorsensor.boiler_hpbrinein501/101521
2486Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpbrineoutbrine out/condenserint16 (>=-3199<=3199)Cfalsesensor.boiler_brine_out/condensersensor.boiler_hpbrineout501/101531
2487Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptc0heat carrier return (TC0)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_return_(TC0)sensor.boiler_hptc0501/101541
2488Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptc1heat carrier forward (TC1)int16 (>=-3199<=3199)Cfalsesensor.boiler_heat_carrier_forward_(TC1)sensor.boiler_hptc1501/101551
2489Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptc3condenser temperature (TC3)int16 (>=-3199<=3199)Cfalsesensor.boiler_condenser_temperature_(TC3)sensor.boiler_hptc3501/101561
2490Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptr1compressor temperature (TR1)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_temperature_(TR1)sensor.boiler_hptr1501/101571
2491Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptr3refrigerant temperature liquid side (condenser output) (TR3)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3)sensor.boiler_hptr3501/101581
2492Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptr4evaporator inlet temperature (TR4)int16 (>=-3199<=3199)Cfalsesensor.boiler_evaporator_inlet_temperature_(TR4)sensor.boiler_hptr4501/101591
2493Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptr5compressor inlet temperature (TR5)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_inlet_temperature_(TR5)sensor.boiler_hptr5501/101601
2494Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptr6compressor outlet temperature (TR6)int16 (>=-3199<=3199)Cfalsesensor.boiler_compressor_outlet_temperature_(TR6)sensor.boiler_hptr6501/101611
2495Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptr7refrigerant temperature gas side (condenser input) (TR7)int16 (>=-3199<=3199)Cfalsesensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7)sensor.boiler_hptr7501/101621
2496Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptl2air inlet temperature (TL2)int16 (>=-3199<=3199)Cfalsesensor.boiler_air_inlet_temperature_(TL2)sensor.boiler_hptl2501/101631
2497Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hppl1low pressure side temperature (PL1)int16 (>=-3199<=3199)Cfalsesensor.boiler_low_pressure_side_temperature_(PL1)sensor.boiler_hppl1501/101641
2498Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpph1high pressure side temperature (PH1)int16 (>=-3199<=3199)Cfalsesensor.boiler_high_pressure_side_temperature_(PH1)sensor.boiler_hpph1501/101651
2499Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hpta4drain pan temp (TA4)int16 (>=-3199<=3199)Cfalsesensor.boiler_drain_pan_temp_(TA4)sensor.boiler_hpta4501/101661
2500Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196iboiler172hptw1reservoir temp (TW1)int16 (>=-3199<=3199)Cfalsesensor.boiler_reservoir_temp_(TW1)sensor.boiler_hptw1501/101671